    CentriPro4" Motors and Controls

    AGENCY LISTINGS:

    Control BoxMay Replace May Replace May Replace

    EnclosureShipping

    Order HP KW VoltsGP # RJ # FE #

    DimensionsWeight (lbs)

    Number W x D x H (in)

    CB05412CR 0.5 .37 230 NA

    50F311CB 2824055015 8.1 x 5.9 x 9.3 7

    S50N1CB, A50N1CB

    CB07412CR .75 .55 230 NA

    75F311CB 2824075015 8.1 x 5.9 x 9.3 7

    S75N1CB, A75N1CB

    CB10412CR 1 .75 230 NA

    S100F311CB 2824085015 8.1 x 5.9 x 9.3 7

    S100N1CB, A100N1CB

    CB15412CR 1.5 1.1 230 00074

    150F311CB282 3008 110 8.1 x 5.9 x 9.3 7

    S150N1CB, A150N1CB

    CB20412CR 2 1.5 230 00084

    200F311CB282 3018 110 8.1 x 5.9 x 9.3 7

    S200N1CB, AS200T1CB

    CB30412CR 3 2.2 230 00094

    300F311CB282 3028 110 8.1 x 5.9 x 9.3 7

    S300N1CB

    CB50412CR 5 3.7 230 00104

    500F311CB282 1138 110 8.1 x 5.9 x 9.3 8

    S500N1CB

    CSCR (Capacitor Start-Capacitor Run) Control Box Features

    Vltage Rela fr installer cnvenience

    230 vlt standard mdels 208 vlt rela, rder n. 9K479 is available fr lw vltageapplicatins

    Start Capacitrs fr starting trque

    Run Capacitrs fr efcienc and quiet peratin

    Tpe 3R enclsure fr indr r utdr munting

    Accepts up t #2 AWG wire

    Multiple knckuts and tw grund terminals

    Higher HP mdels require heav dut pressure switches See Magnetic Cntactr versin t use standard pressure switches

    Manual reset verlads n 1 5 HP mdels

    Note:208 Volt starting relay is available as a repair part for 200-208 volt power supplies, 9K461.

    Quick Disconnect Control Box Features

    Vltage Relas fr installer cnvenience 115 and 230 vlt mdels

    208 vlt rela available fr lw vltage applicatins Start Capacitrs

    NEMA 3R enclsure fr indr r utdr munting Multiple knckuts

    Quick discnnect cver design will retrt with F.E. Q-D cntrl bxes Tw grund lugs

    CentriPro Order Numbers

    Control Box

    HP KW Volts

    Replaces Replaces Enclosure Dimensions Shipping

    Order Number old # FE # W x D x H (in) Weight (lbs)

    CB05411 .5 .37 115 00043 280 104 49 4.8 x 2.9 x 8.4 4

    CB05412 .5 .37 230 00044 280 105 49 4.8 x 2.9 x 8.4 4

    CB07412 .75 .55 230 00054 280 107 49 4.8 x 2.9 x 8.4 4

    CB10412 1 .75 230 00064 280 108 49 4.8 x 2.9 x 8.4 4

    AGENCY

    LISTINGS:

    UL

    C US

    ULTESTED To UL AND CSASTANDARDS By UL.

  • 7/24/2019 Gould Pumps

    2/12

    CentriProQuick Disconnect Control BoxesFor 4", 1, 3-Wire Submersible Motors

    ITT Residential Water

    FEATURES

    Voltage Relays for installer convenience

    115 and 230 volt models

    208 volt relay, 9K461, available for lowvoltage applications

    Start Capacitors

    NEMA 3R enclosure for indoor or out-door mounting

    Quick disconnect cover design will retro-

    fit with F.E. Q-D control boxesMultiple knockouts

    Two grounding lugs

    AGENCY LISTINGS

    CentriPro is a brand of ITT Corporation.

    www.centripro.com

    Engineered for life

    CentriPro

    CSA certified to C22.2, No. 108 Standardby Canadian Standards Association,File No. LR38549

    Listed to UL778 Standard by UnderwritersLaboratories Inc. File No. E83318

    UL

  • 7/24/2019 Gould Pumps

    3/12

    ITT CENTRIPROResidential Water

    2

    K REPAIR PARTS FOR QUICK DISCONNECT STYLE CONTROL BOXES*

    CentriPro Old Capacitor StartCapacitor Capacitor

    StartSupplier

    Order Order HP Volts Order CapacitorVoltage Quantity

    RelayNumber

    Number Number Number Mfd Order No.

    CB05411 00043 (GP) .5 115 9K450 250 - 300 125 1 9K457

    RVA7AA (6L)(or KL)

    CB05412 00044 (GP) .5 230 9K448 59 - 71 220 1RVA2AL (6L)

    CB07412 00054 (GP) .75 230 9K449 86 - 103 220 1 9K462(or KL)

    CB10412 00064 (GP) 1 230 9K447 105 - 126 220 1

    Special 208 V Relay for .5 - 1 HP operating on 200 or 208 volt power supplies Order No. 9K461.

    * Repair parts above will work in new voltage relay control boxes as well as in control boxes shown in "ReplacesColumn" above.

    Note:208 Volt starting relay, 9K461, is available for 200-208 volt power supplies.

    CENTRIPRO ORDER NUMBERS

    Control Box ReplacesReplaces

    StandardStandard

    Dual Element EnclosureShipping

    Order HP KW Volts oldFE #

    CircuitFuse

    Time Delay DimensionsWt. (lbs)

    Number # Breaker Fuse W x D x H (in)

    CB05411 .5 .37 115 00043 280 104 49 30 A 35 A 20 A 4.8 x 2.9 x 8.4 4

    CB05412 .5 .37 230 00044 280 105 49 15 A 20 A 10 A 4.8 x 2.9 x 8.4 4

    CB07412 .75 .55 230 00054 280 107 49 20 A 25 A 15 A 4.8 x 2.9 x 8.4 4

    CB10412 1 .75 230 00064 280 108 49 25 A 30 A 20 A 4.8 x 2.9 x 8.4 4

  • 7/24/2019 Gould Pumps

    4/12

    ITT CENTRIPROResidential Water

    3

    INSTALLING A PumpSaverINSIDER

    1. Remove the cover from the front of the 3-wire CentriProcontrol box.

    2. Remove the yellow wire from the terminal strip at L2.

    3. Remove the black wire from L1 to the capacitor.

    4. Press the PumpSaver onto the L1 and L2 terminals.

    5. Reconnect the yellow wire to L2 on the PumpSaver.

    6. Connect the blue wire attached to the PumpSaver to thedual-lug terminal (with the black wire) of the capacitor.

    ORANGE

    BLUE

    BLK VOLTAGERELAY

    1

    2

    5

    YEL

    YELRED

    B(MAIN) Y(COMM) R(START) L2 L1

    MODEL 111/231INSIDER

  • 7/24/2019 Gould Pumps

    5/12

    ITT

    CentriPro and the ITT Engineered Blocks Symbol areregistered trademarks and tradenames of ITT Corporation.

    PumpSaver is a registered trademark of SymCom, Inc.

    SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

    BCQD April, 2008

    2008 ITT Corporation

    Engineered for life

    Residential Water

    CentriPro

    WIRING DIAGRAM

    GND

    GREEN

    GND

    GREEN

    BLACK BLACK

    START

    CAPACITORRELAY

    ORANGE

    RED

    YELLOW

    MAIN (B) COMM (Y) START (R) L2 L1

    1

    2 5

    Y

    EL.

    (MOTOR LEADS) (LINE LEADS)

  • 7/24/2019 Gould Pumps

    6/12

    4

    CentriPro4" Motors and Controls

    AGENCY LISTINGS:

    Control BoxMay Replace May Replace May Replace

    EnclosureShipping

    Order HP KW VoltsGP # RJ # FE #

    DimensionsWeight (lbs)

    Number W x D x H (in)

    CB05412CR 0.5 .37 230 NA

    50F311CB 2824055015 8.1 x 5.9 x 9.3 7

    S50N1CB, A50N1CB

    CB07412CR .75 .55 230 NA

    75F311CB 2824075015 8.1 x 5.9 x 9.3 7

    S75N1CB, A75N1CB

    CB10412CR 1 .75 230 NA

    S100F311CB 2824085015 8.1 x 5.9 x 9.3 7

    S100N1CB, A100N1CB

    CB15412CR 1.5 1.1 230 00074

    150F311CB282 3008 110 8.1 x 5.9 x 9.3 7

    S150N1CB, A150N1CB

    CB20412CR 2 1.5 230 00084

    200F311CB282 3018 110 8.1 x 5.9 x 9.3 7

    S200N1CB, AS200T1CB

    CB30412CR 3 2.2 230 00094

    300F311CB282 3028 110 8.1 x 5.9 x 9.3 7

    S300N1CB

    CB50412CR 5 3.7 230 00104

    500F311CB282 1138 110 8.1 x 5.9 x 9.3 8

    S500N1CB

    CSCR (Capacitor Start-Capacitor Run) Control Box Features

    Vltage Rela fr installer cnvenience

    230 vlt standard mdels 208 vlt rela, rder n. 9K479 is available fr lw vltageapplicatins

    Start Capacitrs fr starting trque

    Run Capacitrs fr efcienc and quiet peratin

    Tpe 3R enclsure fr indr r utdr munting

    Accepts up t #2 AWG wire

    Multiple knckuts and tw grund terminals

    Higher HP mdels require heav dut pressure switches See Magnetic Cntactr versin t use standard pressure switches

    Manual reset verlads n 1 5 HP mdels

    Note:208 Volt starting relay is available as a repair part for 200-208 volt power supplies, 9K461.

    Quick Disconnect Control Box Features

    Vltage Relas fr installer cnvenience 115 and 230 vlt mdels

    208 vlt rela available fr lw vltage applicatins Start Capacitrs

    NEMA 3R enclsure fr indr r utdr munting Multiple knckuts

    Quick discnnect cver design will retrt with F.E. Q-D cntrl bxes Tw grund lugs

    CentriPro Order Numbers

    Control Box

    HP KW Volts

    Replaces Replaces Enclosure Dimensions Shipping

    Order Number old # FE # W x D x H (in) Weight (lbs)

    CB05411 .5 .37 115 00043 280 104 49 4.8 x 2.9 x 8.4 4

    CB05412 .5 .37 230 00044 280 105 49 4.8 x 2.9 x 8.4 4

    CB07412 .75 .55 230 00054 280 107 49 4.8 x 2.9 x 8.4 4

    CB10412 1 .75 230 00064 280 108 49 4.8 x 2.9 x 8.4 4

    AGENCY

    LISTINGS:

    UL

    C US

    ULTESTED To UL AND CSASTANDARDS By UL.

  • 7/24/2019 Gould Pumps

    7/12

    Residential Water Systems

    FEATURES

    Voltage Relay for installer convenience230 volt models 208 volt relay, 9K479,

    available for low voltage applications

    Start Capacitors for starting torque

    Run Capacitors for efficiency and quietoperation

    Type 3R enclosure for indoor or outdoormounting

    Accepts up to #2 AWG wire

    Multiple knockouts and two groundterminals

    Higher HP models require heavy duty pres-sure switches See Magnetic Contactorversion to use standard pressure switches

    Manual reset overloads on 1 5 HPmodels

    AGENCY LISTINGS

    ITT

    CentriProCSCR 1 Control BoxesCapacitor Start - Capacitor Run for3-wire, 5 HP Submersible Motors

    CentriPro is a brand of ITT Corporation.

    www.centripro.com

    Engineered for life

    CentriPro

    C US

    UL TESTED TO UL AND CSA STANDARDS BY UL.

    BCCR

  • 7/24/2019 Gould Pumps

    8/12

    Control Box MayMay Replace May Replace

    StandardStandard

    Dual Element EnclosureShipping

    Order Hp KW Volts ReplaceRJ # FE #

    CircuitFuse

    Time Delay DimensionsWt. (lbs)

    Number GP # Breaker Fuse W x D x H (in)

    CB05412CR 0.5 .37 230

    50F311CB2824055015 15 20 10 8.1 x 5.9 x 9.3 7

    S50N1CB, A50N1CB

    CB07412CR .75 .55 230

    75F311CB2824075015 20 25 15 8.1 x 5.9 x 9.3 7

    S75N1CB, A75N1CB

    CB10412CR 1 .75 230

    S100F311CB2824085015 25 30 20 8.1 x 5.9 x 9.3 7

    S100N1CB, A100N1CB

    CB15412CR 1.5 1.1 230 00074

    150F311CB282 3008 110 30 35 20 8.1 x 5.9 x 9.3 7

    S150N1CB, A150N1CB

    CB20412CR 2 1.5 230 00084

    200F311CB282 3018 110 25 30 20 8.1 x 5.9 x 9.3 7

    S200N1CB, AS200T1CB

    CB30412CR 3 2.2 230 00094 300F311CB 282 3028 110 40 45 30 8.1 x 5.9 x 9.3 7 S300N1CB

    CB50412CR 5 3.7 230 00104

    500F311CB282 1138 110 60 80 45 8.1 x 5.9 x 9.3 8

    S500N1CB

    ITT

    CentriPro is a registered trademark of ITT Corporation. ITT,the Engineered Blocks Symbol and Engineered for Life areRegistered trademarks of ITT Manufacturing Enterprises, Inc.

    SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

    BCCR January, 2010Copyright (c) 2010 ITT Corporation

    Engineered for life

    Residential Water Systems

    CentriPro

    K REPAIR PARTS

    Control Box Old Control CapacitorCapacitor Capacitor Capacitor Capacitor

    Overload Start Relay Order HP Volts Box Order Repair Part

    Mfd. Type Voltage Quantity Order Order

    Number Number Number Number Number

    CB05412CR .5 230

    9K465 43-53 Start 2501 NA 9K458

    9K466 15 Run 370

    CB07412CR .75 230 9K448 59-71 Start 250

    1 N/A 9K458 9K467 23 Run 370

    CB10412CR 1 230 9K449 86-103 Start 250

    1 N/A 9K458 9K467 23 Run 370

    CB15412CR 1.5 230 00074 9K447 105-126 Start 250

    1 9K471 9K458 9K452 10 Run 370

    CB20412CR 2 230 00084 9K447 105-126 Start 250

    1 9K481 9K458 9K451 20 Run 370

    CB30412CR 3 230 00094 9K453 208-250 Start 250

    1 9K4829K454 45 Run 370

    9K459

    CB50412CR 5 230 00104 9K455 270-324 Start 330 1

    9K4839K456 40 Run 370 2

    New 1 HP CSCR control box is now in a larger enclosure, it is notin a quick disconnect style enclosure.

    Overloads for 2, 3 and 5 HP CSCR boxes are sold prewired andsoldered as an assembly. No field soldering or wiring required.

    If supply voltage is between 200 V 210 V a 208 V start relay,order no. 9K479, is required.

  • 7/24/2019 Gould Pumps

    9/12

    5

    Features

    Built-in Magnetic Contactors allow the use ofstandard pressure switches, prolong switchlife and eliminate the need to source andinstall separate contactors, saving installationtime and reducing total system componentcosts.

    Voltage Relay for installer convenience

    230 volt standard models 208 volt relay,order no. 9K479 is available for low voltageapplications

    Start Capacitors for starting torque

    Run Capacitors for efciency and quietoperation

    Type 3R enclosure for indoor or outdoormounting

    Accepts up to #2 AWG wire

    Multiple knockouts and two groundterminals

    Manual reset overloads on 1 5 HPmodels

    AGENCY LISTINGS:

    MAGNETIC CONTACTOR 1 CONTROL BOXESFor 3-wire, 1 5 HP Submersible Motors

    C US

    UL TESTED To UL AND CSA STANDARDS By UL.

    1 3 HP

  • 7/24/2019 Gould Pumps

    10/12

    Residential Water Systems

    FEATURES

    Built-in Magnetic Contactors allow the use

    of standard pressure switches, prolongswitch life and eliminate the need to sourceand install separate contactors, savinginstallation time and reducing total systemcomponent costs.

    Voltage Relay for installer convenience

    230 volt standard models 208 volt relay,9K479 available for low voltage applications

    Start Capacitors for starting torque

    Run Capacitors for efficiency and quietoperation

    Type 3R enclosure for indoor or outdoormounting

    Accepts up to #2 AWG wire

    Multiple knockouts and two groundterminals

    Manual reset overloads on 1 5 HPmodels

    AGENCY LISTINGS

    ITT

    CentriProMagnetic Contactor 1 Control BoxesFor 3-wire, 1 5 HP Submersible Motors

    CentriPro is a brand of ITT Corporation.

    www.centripro.com

    Engineered for life

    CentriPro

    C US

    UL TESTED TO UL AND CSA STANDARDS BY UL.

    1 3 HP

    5 HP is in larger enclosure

    BCMC

  • 7/24/2019 Gould Pumps

    11/12

    ITT

    CentriPro is a registered trademark of ITT Corporation. ITT,the Engineered Blocks Symbol and Engineered for Life areRegistered trademarks of ITT Manufacturing Enterprises, Inc.

    SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

    BCMC January, 2010Copyright (c) 2010 ITT Corporation

    Engineered for life

    Residential Water Systems

    CentriPro

    MAGNETIC CONTACTOR (MC) CONTROL BOXES FOR 3 WIRE, 1,

    4" CENTRIPRO MOTORS AND 4" (6", 5 HP) FRANKLIN ELECTRIC MOTORS

    Control Box

    Replaces Replaces Replaces

    StandardStandard

    Dual Element EnclosureShipping

    Order Number

    HP KW VoltsGP # RJ # FE #

    CircuitFuse

    Time Delay DimensionsWt. (lbs)

    Breaker Fuse W x D x H (in)

    CB15412MC 1.5 1.1 230 No Equal No Equal No Equal 30 35 20

    CB20412MC 2 1.5 230 00084MC No Equal 2823018310 25 30 20 8.1 x 5.9 x 9.3 8

    CB30412MC 3 2.2 230 00094MC S300N1CBC 2823028310 40 45 30

    CB50412MC 5 3.7 230 00104MC S500N1CBC 2821139310 60 80 45 11 x 6.7 x 12.5 15

    "K" REPAIR PARTS FOR MAGNETIC CONTACTOR "MC" CONTROL BOXES

    Control Box

    CapacitorCapacitor Capacitor Capacitor Capacitor

    Contactor Overload Start Relay

    Order Number HP KW Volts Repair Part

    Type Mfd. Voltage Quantity Order Order Order

    Number Number Number Number

    CB15412MC 1.5 1.1

    9K447 Start 105-126 2509K493

    9K452 Run 10 370

    CB20412MC 2 1.5 9K447 Start 105-126 250

    1

    9K485 9K480 (S)

    9K458

    230 9K451 Run 20 370 9K472 (M)

    CB30412MC 3 2.2 9K453 Start 208-250 250 9K473 (S)

    9K454 Run 45 370 9K474 (M)

    CB50412MC 5 3.7 9K455 Start 270-324 330 1 9K486 9K475 (S) 9K459 9K456 Run 40 370 2 9K476 (M)

    Repair parts above are compatible with and replace parts in old Goulds Pumps or Franklin Electric control boxes.

    If supply voltage is between 200 V 210 V a 208 V start relay, order no. 9K479, is required.

  • 7/24/2019 Gould Pumps

    12/12

    7

    BALANCED FLOW

    BF20, BF30 and BF50Constant Pressure Controllers for -2, 3 and 5 HP Submersible Pumps

    Features

    Enclosure Rating: NEMA 3R, IP22 rainproof,indoor/outdoor enclosure. Allows mountingthe controller outdoors.

    Current Limit Selector Switch: Rotary switchto set current limit to match motor ServiceFactor Amps (SFA).

    The controller may be used on smallerpump/motor combinations as long as themotor SFA is within the current limit rangeof the controller.

    Communications Port: RS-232 serial portto facilitate software updates and futureexpansion.

    Three sizes available for - 5 HP pumps.

    Constant Pressure: The system providesconsistent pressure even as system owrequirements vary.

    Controller acts as a pump protection deviceand troubleshooting device.

    Flashing LED lights indicate system faults bynumber of ashes.

    Controller will operate between 190 and260 volts.

    Includes a pressure sensor and sensor cable.

    Integrated output motor lter protectsthe motor from voltage spikes and limitselectrical interference with devices such asportable telephones, radios, televisions andgarage door openers.

    Cooling fan: Allows operation in ambienttemperatures up to 122F.


Recommended