+ All Categories
Home > Documents > GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1...

GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1...

Date post: 01-Mar-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
8
GR BluePRO 150/2/G40H A1CM/50 www.zenit.com All data are property of Zenit 1 Constructive characteristics Technical data Use limits Test limits Materials Impeller with grinder system 1.1 kW 0 mm Rated power output (P2) Free passage Number of poles 2 Rated power output (P2) 1.1 kW Input power (P1) 1.6 kW Nominal absorbed current (In) 7.5 A rated power factor (cos phi) 0.95 Nominal power frequency (f) 50 Hz Rated nominal voltage(Vn) 230 V N° phases 1 IPMotor 68 ATEX thermal class not applicable insulation class F Outlet G1"½ DN32 PN6 Outlet orientation H (horizontal) Type of starting D Weight 24 kg Standard cable type H07RN-F 3G1 EX cable type N.A. Standard paint type Bicomponent epoxy paint Maximum acoustic pressure 70 dB Set of standard mechanical seals Two Silicon carbide mechanical seals (SiC) Probe for water presence Maximum operating temperature 40 °C Maximum immersion depth 20 m PH of treated fluid 6 to 11 pH max starts per hour 20 Density of treated fluid 1 Kg/dm³ Viscosity of treated fluid 1 mm²/s Case Grey Cast Iron - EN-GJL 250 (02) Shaft Stainless Steel - AISI 420 (23) Cooling jacket Not applicable (00) Standard gasket Rubber - NBR (77) EX gasket Not applicable (00) Nuts and bolts Stainless Steel - Class A2-70 (42) Hydraulic Grey Cast Iron - EN-GJL 250 (02) Impeller Grey Cast Iron - EN-GJL 250 (02) Cutting disk Tool Stainless Steel - X102 CrMo17 KU (16) Cutter Tool Stainless Steel - X102 CrMo17 KU (16) Grid Not applicable (00) GR BluePRO 150/2/G40H A1CM/50
Transcript
Page 1: GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1 Technical data Constructive characteristics Use limits Test limits Materials Impeller

GR BluePRO 150/2/G40H A1CM/50

www.zenit.com All data are property of Zenit 1

Constructive characteristicsTechnical data

Use limits

Test limits

Materials

Impeller with grinder system

1.1 kW

0 mm

Rated power output (P2)

Free passage

Number of poles 2

Rated power output (P2) 1.1 kW

Input power (P1) 1.6 kW

Nominal absorbed current (In) 7.5 A

rated power factor (cos phi) 0.95

Nominal power frequency (f) 50 Hz

Rated nominal voltage(Vn) 230 V

N° phases 1

IPMotor 68

ATEX thermal class not applicable

insulation class F

Outlet G1"½ DN32 PN6

Outlet orientation H (horizontal)

Type of starting D

Weight 24 kg

Standard cable type H07RN-F 3G1

EX cable type N.A.

Standard paint type Bicomponent epoxy paint

Maximum acoustic pressure 70 dB

Set of standard mechanical seals Two Silicon carbide mechanical seals (SiC)

Probe for water presence

Maximum operating temperature 40 °C

Maximum immersion depth 20 m

PH of treated fluid 6 to 11 pH

max starts per hour 20

Density of treated fluid 1 Kg/dm³

Viscosity of treated fluid 1 mm²/s

Case Grey Cast Iron - EN-GJL 250 (02)

Shaft Stainless Steel - AISI 420 (23)

Cooling jacket Not applicable (00)

Standard gasket Rubber - NBR (77)

EX gasket Not applicable (00)

Nuts and bolts Stainless Steel - Class A2-70 (42)

Hydraulic Grey Cast Iron - EN-GJL 250 (02)

Impeller Grey Cast Iron - EN-GJL 250 (02)

Cutting disk Tool Stainless Steel - X102 CrMo17 KU (16)

Cutter Tool Stainless Steel - X102 CrMo17 KU (16)

Grid Not applicable (00)

GR BluePRO 150/2/G40H A1CM/50

Page 2: GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1 Technical data Constructive characteristics Use limits Test limits Materials Impeller

GR BluePRO 150/2/G40H A1CM/50

www.zenit.com All data are property of Zenit 2

Pump

Page 3: GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1 Technical data Constructive characteristics Use limits Test limits Materials Impeller

GR BluePRO 150/2/G40H A1CM/50

www.zenit.com All data are property of Zenit 3

Bottom coupling devices with horizontal outlet

Page 4: GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1 Technical data Constructive characteristics Use limits Test limits Materials Impeller

GR BluePRO 150/2/G40H A1CM/50

www.zenit.com All data are property of Zenit 4

Page 5: GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1 Technical data Constructive characteristics Use limits Test limits Materials Impeller

GR BluePRO 150/2/G40H A1CM/50

www.zenit.com All data are property of Zenit 5

Bottom coupling devices with vertical outlet

Page 6: GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1 Technical data Constructive characteristics Use limits Test limits Materials Impeller

GR BluePRO 150/2/G40H A1CM/50

www.zenit.com All data are property of Zenit 6

Page 7: GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1 Technical data Constructive characteristics Use limits Test limits Materials Impeller

GR BluePRO 150/2/G40H A1CM/50

www.zenit.com All data are property of Zenit 7

Page 8: GR BluePRO 150/2/G40H A1CM/50...GR BluePRO 150/2/G40H A1CM/50 All data are property of Zenit 1 Technical data Constructive characteristics Use limits Test limits Materials Impeller

GR BluePRO 150/2/G40H A1CM/50

www.zenit.com All data are property of Zenit 8


Recommended