WHAT IS FAÇADE
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
‡ Outer skin of building
‡ Made of RC, Bricks, Metal or Glass
‡ Aesthetics
‡ Weather proof
‡ Sound proof
‡ Shape & Identity
WHAT IS FAÇADE ?
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
WHAT IS FAÇADE ?
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
GLASS FAÇADE
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
‡ Outer skin made of Glass
‡ Most preferred type of facade
‡ 60% to 70% Glass in any commercial
buildings
‡ Allows day light into the building
‡ Curtain Walls, Structural Glazing,
Ventilated Facades, Double skin facades
etc.
GLASS FAÇADE
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
SUSTAINABLE GLAZING
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
SUSTAINABLE GLAZING
‡ ENERGY EFFICIENT
‡ Majorly influenced by facade
‡ USE OF RECYCLABLE MATERIAL
‡ Aluminum and glass
‡ USE OF REGIONAL MATERIAL
‡ Within 400km of the project location
‡ LOW VOC SELANTS AND ADHESIVES
‡ Less than 100gms/l
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
SUSTAINABLE GLAZING
‡ Weather proof
‡ THERMAL
‡ NOISE
‡ LIGHTING
‡ AESTHETICS
‡ ECONOMIC
‡ EFFICIENT
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
SUSTAINABLE GLAZING
‡ LESS SOLAR GAIN
‡ MORE DAY LIGHT
‡ LESS GLARE
‡ AMBIENT TEMP.
‡ RECYCLED MATERIAL
‡ OPTIMUM DESIGN
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
ECBC RECOMMENDATION
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
What is ECBC ?
‡ Energy Conservation building code
‡ Bureau of Energy Efficiency (BEE).
o Ministry of Power.
‡ India - 5 Climatic Zones
‡ Guideline - Fenestration, HVAC, Lighting etc.
‡ Chapter 4 – Building envelope
‡ LEED Recommends ECBC
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
Indian Climatic Classification
‡ WARM & HUMID
‡ Chennai/Mumbai/Kolkata
‡ HOT & DRY
‡ Ahmedabad/Jaipur
‡ MODERATE / TEMPERATE
‡ Bengaluru
‡ COMPOSITE
‡ Delhi/Lucknow/Hyderabad
‡ COLD
‡ Dehradun/Guwahati
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
Thermal performance of facade
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
Solar factor
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
SF Calculation with Shading Device
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
Max SF & U Value allowable
Climate specific Energy Conservation and Indoor thermal comfort measures
are detailed out in Table 4.3 (ECBC User Guide)
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
Requirements for sky light
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
Minimum VLT requirement
As the WWR is increased the Minimum VLT requirement is reduced.
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
GLAZING MATERIAL SELECTION
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
Thumb Rule FOR A GREENER FACADE
‡ Windows shall be optimally sized and placed
‡ Keep WWR < 40%
‡ Maximum windows towards North & South
‡ Minimum windows towards West and East
‡ Vary the glass w.r.t orientation if possible
‡ Use shading devices if required.
‡ Use more of Recycled Content
‡ Check VOC content of Sealants
‡ Use locally made materials
Our CapabilitiesB &F IC - L&T
Center for Excellence and Futuristic DevelopmentL&T ConstructionBuildings & Factories
Green Building Facilitation (Completed and Ongoing)
TC II- L&T Campus, Chennai
LEED NC – Certified (USGBC)
EDRC, L&T Campus, Chennai
LEED EB -Silver rated (USGBC)
CTS@ MEPZ, Chennai
LEED NC - Gold rated (IGBC)
CTS @ Kolkata
LEED NC - Silver rated (IGBC)
TC III@ L&T Campus, Chennai
LEED NC – Silver Rated (IGBC)
MDC@ Lonovala
LEED NC – Gold rated (IGBC)
CMRL @ Koyembedu, Chennai
LEED NC – Platinum Proposed (IGBC)
CTS @ Pune
LEED NC – Silver Proposed (IGBC)
Cognizant Technology Solutions @
Kolkata, Phase 2
LEED NC – Silver Proposed (IGBC)
TCS @ Kolkata
LEED NC – Platinum Proposed (IGBC)
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
Sustainable building consultancies (In house)
Sustainable Building Consultancy
Façade Engineering
Applied Research
Capacity Building
Larsen and Larsen and ToubroToubro ConstructionConstruction GBC HYDERABAD GBC HYDERABAD -- 20122012
OUR APPROACH