+ All Categories
Home > Documents > GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Date post: 29-Jan-2017
Category:
Upload: duongcong
View: 273 times
Download: 6 times
Share this document with a friend
19
- Instant delivery from stock, covering more than 1000 variants GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS
Transcript
Page 1: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

- Instant delivery from stock, covering more than 1000 variants

GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Page 2: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

IMPROVING AVAILABILITY ABOUT GRUNDFOS SP PUMPS

Grundfos SP pumps combine the very best materials with superior hydraulic design and are renowned for their high efficiency and reliability throughout the range.

• Stainless steel for all environments Made entirely of corrosion-resistant stainless steel in three different

grades, SP pumps are ideal for a wide variety of applications.

• Motors made to match the pump Grundfos MS and MMS submersible motors are developed specially for the SP

pump. This ensures reliability, high efficiency and keeps lifecycle costs low.

• Monitoring and controls Save energy, add functionality and increase reliability of your SP system by

using a Grundfos CUE frequency converter pre-programmed for controlling SP pump operation with advanced functions for supporting pump applications, or a Grundfos MP 204 motor protection offering a set of warning limits, trip limits and a wide range of functions and alarms.

• Grundfos Remote Management This Internet-based performance monitoring and alarm solution is an

efficient and cost effective alternative to costly SCADA systems or similar. Get reliable performance data from the pumping installation at a very low cost, with complete system security and reliability.

• Grundfos service & solutions Grundfos service products are available through a global network with a

local presence in all markets and add a little extra that gives a huge amount of value to your SP system. Find available service products at www.grundfos.com/service-support.

For further information about the Grundfos Submersible SP pumps, please visit Grundfos Product Center: www.grundfos.com/products/find-product.html

Grundfos SP submersible borehole pumps are well known for their high quality, reliability and efficiency and offer a range of valuable benefits to customers and installers.

One of the key buying factors when selecting a submersible borehole pump is availability of pumps where and when needed.

We are always offering a flexible and fast supply of products from our global supply chain, but we also know we can do better. We have therefore improved the availability of SP pumps by building a large stock of pumps and adding fast transportation from the location, so we can deliver pumps instantly, when needed.

This pocket guide shows you the large range of pumps in stock covering more than 1000 variants that are available for instant delivery.

2 3

Page 3: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

HOW DOES THE GUIDE WORK?

FIND YOUR PUMP VIA SEARCH 1) Open the PDF document, Press “Ctrl”+F

2) Type in the product number. If the product number appears in

a. “Product number In stock” – your pump is in stock

b. “Pumps with similar performance” – the pumps to the left are in stock and can be used

3) Contact your local Grundfos office for your next delivery

Or you can simply identify your pump with the curves and the related tables.

VIEW DETAILS AND COMPARE PERFORMANCE ONLINE Once you have found your pump, visit the online Grundfos Product Center at product-selection.grundfos.com and type in the product number, for more information about the selected pump and for calculating your drop cable.

What is in the replacement guide:

The information in the tables is mainly self-explanatory, except perhaps the column “Pumps with similar performance”.

The product numbers in this column are all pumps in Grundfos Product Center that have the same performance curve and are of the same material (1.4301) as the pump in stock.

The difference is different phases, different voltages, different start form, with/without valves, and so on.

The purpose of the list is to ask you to consider if the pump in stock can be used instead of one of the other product numbers in Grundfos Product Center, as it has the same duty point and is the same material version.

4 5

Page 4: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

09001K06 SP 2A-6 MS402 0.37 3 x 380-415 YES DOL Rp1 1/4 EN 1.4301

09001006; 09001906; 09001A06; 09001K06; 09002106; 09002406; 09002B06; 09002E06; 09007106; 09007406; 09007506; 09051K06;

09052106; 09057106

09001K09 SP 2A-9 MS402 0.37 3 x 380-415 YES DOL Rp1 1/4 EN 1.4301

09001009; 09001909; 09001A09; 09001K09; 09002109; 09002409; 09002B09; 09002E09; 09007109; 09007409; 09007509; 09051K09;

09052109; 09057109

09007F13 SP 2A-13 MS402 0.55 1x220-240, PSC YES DOL Rp1 1/4 EN 1.4301

09000913; 09001013; 09001913; 09001A13; 09001K13; 09002113; 09002413; 09002B13; 09002E13; 09007113; 09007413; 09007513; 09051K13; 09052113; 09057113

09007513 SP 2A-13 MS402 0.55 1x220-240, PSC No DOL Rp1 1/4 EN 1.4301

09000913; 09001013; 09001913; 09001A13; 09001K13; 09002113; 09002413; 09002B13; 09002E13; 09007113; 09007413; 09007513; 09051K13; 09052113; 09057113

09001K13 SP 2A-13 MS402 0.55 3 x 380-415 YES DOL Rp1 1/4 EN 1.4301

09000913; 09001013; 09001913; 09001A13; 09001K13; 09002113; 09002413; 09002B13; 09002E13; 09007113; 09007413; 09007513; 09051K13; 09052113; 09057113

09007F18 SP 2A-18 MS402 0.75 1x220-240, PSC YES DOL Rp1 1/4 EN 1.4301

09000918; 09001018; 09001918; 09001A18; 09001K18; 09002118; 09002418; 09002B18; 09002E18; 09007118; 09007418; 09007518; 09051K18; 09052118; 09057118

09001K18 SP 2A-18 MS402 0.75 3 x 380-415 YES DOL Rp1 1/4 EN 1.4301

09000918; 09001018; 09001918; 09001A18; 09001K18; 09002118; 09002418; 09002B18; 09002E18; 09007118; 09007418; 09007518; 09051K18; 09052118; 09057118

09007F23 SP 2A-23 MS402 1.10 1x220-240, PSC YES DOL Rp1 1/4 EN 1.4301

09001023; 09001923; 09001A23; 09001K23; 09002123; 09002423; 09002B23; 09002E23; 09007123; 09007423; 09007523; 09051K23;

09052123; 09057123

09001K23 SP 2A-23 MS402 1.10 3 x 380-415 YES DOL Rp1 1/4 EN 1.4301

09001023; 09001923; 09001A23; 09001K23; 09002123; 09002423; 09002B23; 09002E23; 09007123; 09007423; 09007523; 09051K23;

09052123; 09057123

09001K28 SP 2A-28 MS402 1.50 3 x 380-415 YES DOL Rp1 1/4 EN 1.4301

09001028; 09001928; 09001A28; 09001K28; 09002128; 09002428; 09002B28; 09002E28; 09051K28;

09052128

09001K33 SP 2A-33 MS402 1.50 3 x 380-415 YES DOL Rp1 1/4 EN 1.4301

09001033; 09001933; 09001A33; 09001K33; 09002133; 09002433; 09002B33; 09002E33; 09051K33;

09052133

SP2A

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp1 ¼ dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

6 7

Page 5: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

96842750 SP 3A-3 MS402 0.37 3 x 380-415 YES DOL Rp1 1/4 EN 1.4301

10007F06 SP 3A-6 MS402 0.37 1x220-240, PSC YES DOL Rp1 1/4 EN 1.430110001006; 10001906; 10001A06; 10001K06; 10002106; 10002406; 10002B06; 10002E06; 10007106; 10007406; 10007506; 10007F06;

10051K06; 10052106; 10057106

10001K06 SP 3A-6 MS402 0.37 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001006; 10001906; 10001A06; 10001K06; 10002106; 10002406; 10002B06; 10002E06; 10007106; 10007406; 10007506; 10007F06;

10051K06; 10052106; 10057106

10007F09 SP 3A-9 MS402 0.55 1x220-240, PSC YES DOL Rp1 1/4 EN 1.430110001009; 10001909; 10001A09; 10001K09; 10002109; 10002409; 10002B09; 10002E09; 10007109; 10007409; 10007509; 10007F09;

10051K09; 10052109; 10057109

10001K09 SP 3A-9 MS402 0.55 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001009; 10001909; 10001A09; 10001K09; 10002109; 10002409; 10002B09; 10002E09; 10007109; 10007409; 10007509; 10007F09;

10051K09; 10052109; 10057109

10007F12 SP 3A-12 MS402 0.75 1x220-240, PSC YES DOL Rp1 1/4 EN 1.430110001012; 10001912; 10001A12; 10001K12; 10002112; 10002412; 10002B12; 10002E12; 10007112; 10007412; 10007512; 10007F12;

10051K12; 10052112; 10057112

10001K12 SP 3A-12 MS402 0.75 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001012; 10001912; 10001A12; 10001K12; 10002112; 10002412; 10002B12; 10002E12; 10007112; 10007412; 10007512; 10007F12;

10051K12; 10052112; 10057112

10051K12 SP 3A-12 MS402 0.75 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001012; 10001912; 10001A12; 10001K12; 10002112; 10002412; 10002B12; 10002E12; 10007112; 10007412; 10007512; 10007F12;

10051K12; 10052112; 10057112

10000012 SP 3A-12 Without motor 0.75 DOL Rp1 1/4 EN 1.4301

10001012; 10001912; 10001A12; 10001K12; 10002112; 10002412; 10002B12; 10002E12; 10007112; 10007412; 10007512; 10007F12;

10051K12; 10052112; 10057112

10007F15 SP 3A-15 MS402 1.10 1x220-240, PSC YES DOL Rp1 1/4 EN 1.430110001015; 10001915; 10001A15; 10001K15; 10002115; 10002415; 10002B15; 10002E15; 10007115; 10007415; 10007515; 10007F15;

10051K15; 10052115; 10057115

10001K15 SP 3A-15 MS402 1.10 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001015; 10001915; 10001A15; 10001K15; 10002115; 10002415; 10002B15; 10002E15; 10007115; 10007415; 10007515; 10007F15;

10051K15; 10052115; 10057115

10051K15 SP 3A-15 MS402 1.10 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001015; 10001915; 10001A15; 10001K15; 10002115; 10002415; 10002B15; 10002E15; 10007115; 10007415; 10007515; 10007F15;

10051K15; 10052115; 10057115

10007F18 SP 3A-18 MS402 1.10 1x220-240, PSC YES DOL Rp1 1/4 EN 1.430110001018; 10001918; 10001A18; 10001K18; 10002118; 10002418; 10002B18; 10002E18; 10007118; 10007418; 10007518; 10007F18;

10051K18; 10052118; 10057118

10001K18 SP 3A-18 MS402 1.10 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001018; 10001918; 10001A18; 10001K18; 10002118; 10002418; 10002B18; 10002E18; 10007118; 10007418; 10007518; 10007F18;

10051K18; 10052118; 10057118

10001K22 SP 3A-22 MS402 1.50 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001022; 10001922; 10001A22; 10001K22; 10002122; 10002422; 10002B22; 10002E22;

10051K22; 10052122

10001K25 SP 3A-25 MS402 1.50 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001025; 10001925; 10001A25; 10001K25; 10002125; 10002425; 10002B25; 10002E25;

10051K25; 10052125

10000025 SP 3A-25 Without motor 1.50 DOL Rp1 1/4 EN 1.4301

10001025; 10001925; 10001A25; 10001K25; 10002125; 10002425; 10002B25; 10002E25;

10051K25; 10052125

10001K29 SP 3A-29 MS402 2.20 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001029; 10001929; 10001A29; 10001K29; 10002129; 10002429; 10002B29; 10002E29;

10051K29; 10052129

10001K33 SP 3A-33 MS402 2.20 3 x 380-415 YES DOL Rp1 1/4 EN 1.430110001033; 10001933; 10001A33; 10001K33; 10002133; 10002433; 10002B33; 10002E33;

10051K33; 10052133

SP3A

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp1 ¼ dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

8 9

Page 6: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

05001K04 SP 5A-4 MS402 0.37 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301

05000904; 05001004; 05001904; 05001A04; 05001K04; 05002104; 05002404; 05002B04; 05002E04; 05007104; 05007404; 05007504; 05007F04; 05051K04; 05052104; 05057104

05001K06 SP 5A-6 MS402 0.55 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301

05000906; 05001006; 05001906; 05001A06; 05001K06; 05002106; 05002406; 05002B06; 05002E06; 05007106; 05007406; 05007506; 05007F06; 05051K06; 05052106; 05057106

05001K08 SP 5A-8 MS402 0.75 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301

05000908; 05001008; 05001908; 05001A08; 05001K08; 05002108; 05002408; 05002B08; 05002E08; 05007108; 05007408; 05007508; 05007F08; 05051K08; 05052108; 05057108

05001K12 SP 5A-12 MS402 1.10 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301

05000912; 05001012; 05001912; 05001A12; 05001K12; 05002112; 05002412; 05002B12; 05002E12; 05007112; 05007412; 05007512; 05007F12; 05051K12; 05052112; 05057112

05007F12 SP 5A-12 MS402 1.10 1x220-240, PSC YES DOL Rp1 1/2 EN 1.4301

05000912; 05001012; 05001912; 05001A12; 05001K12; 05002112; 05002412; 05002B12; 05002E12; 05007112; 05007412; 05007512; 05007F12; 05051K12; 05052112; 05057112

05000012 SP 5A-12 Without motor 1.10 DOL Rp1 1/2 EN 1.4301

05000912; 05001012; 05001912; 05001A12; 05001K12; 05002112; 05002412; 05002B12; 05002E12; 05007112; 05007412; 05007512; 05007F12; 05051K12; 05052112; 05057112

0500FP17 SP 5A-17 Franklin 1.50 1x220, PSC No DOL Rp1 1/2 EN 1.430105000917; 05001017; 05001917; 05001A17; 05001K17; 05002117; 05002417; 05002B17; 05002E17; 05051K17; 05052117; 97636731

05001K17 SP 5A-17 MS402 1.50 3 x 380-415 YES DOL Rp1 1/2 EN 1.430105000917; 05001017; 05001917; 05001A17; 05001K17; 05002117; 05002417; 05002B17; 05002E17; 05051K17; 05052117; 97636731

05000017 SP 5A-17 Without motor 1.50 DOL Rp1 1/2 EN 1.4301

05000917; 05001017; 05001917; 05001A17; 05001K17; 05002117; 05002417; 05002B17; 05002E17; 05051K17; 05052117; 97636731

05001K21 SP 5A-21 MS402 2.20 3 x 380-415 YES DOL Rp1 1/2 EN 1.430105000921; 05001021; 05001921; 05001A21; 05001K21; 05002121; 05002421; 05002B21;

05002E21; 05051K21; 05052121

05001K25 SP 5A-25 MS402 2.20 3 x 380-415 YES DOL Rp1 1/2 EN 1.430105000925; 05001025; 05001925; 05001A25; 05001K25; 05002125; 05002425; 05002B25;

05002E25; 05051K25; 05052125

05001K33 SP 5A-33 MS4000 3.30 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 05000933; 05001033; 05001933; 05001A33; 05001K33; 05051K33; 98625236

SP5A

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp1½ dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

10 11

Page 7: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

98699169 SP 7-5 MS402 0.75 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699150; 98699155; 98699160; 98699169; 98699186

98699179 SP 7-8 MS402 1.10 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699151; 98699156; 98699161; 98699179; 98699187

98699180 SP 7-12 MS402 1.50 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699152; 98699157; 98699162; 98699180; 98699188

98699181 SP7-17 MS402 2.20 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699153; 98699158; 98699163; 98699181; 98699189

98699182 SP 7-23 MS4000 3.30 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699164; 98699182; 98699190; 98699193; 98699200

98699183 SP 7-27 MS4000 4.00 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699165; 98699183; 98699191; 98699194; 98699201

98699184 SP 7-31 MS4000 4.00 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699166; 98699184; 98699192; 98699195; 98699202

98699196 SP 7-37 MS4000 5.50 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699167; 98699170; 98699196; 98699203; 98699207

98699197 SP 7-42 MS4000 5.50 3 x 380-415 YES DOL Rp1 1/2 EN 1.4301 98699168; 98699171; 98699197; 98699204; 98699208

SP7

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp1½ dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

12 13

Page 8: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

98779736 SP 9-4 MS402 0.75 3 x 380-415 YES DOL Rp2 EN 1.4301 98779736; 98780158; 98826877

98699053 SP 9-5 MS402 1.10 3 x 380-415 YES DOL Rp2 EN 1.4301 98699022; 98699025; 98699028; 98699053; 98826878; 98905478

98699054 SP 9-8 MS402 1.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699023; 98699026; 98699029; 98699054; 98826879

98779739 SP 9-10 MS402 2.20 3 x 380-415 YES DOL Rp2 EN 1.4301 98779739; 98779770; 98828504

98699055 SP 9-11 MS402 2.20 3 x 380-415 YES DOL Rp2 EN 1.4301 98699024; 98699027; 98699030; 98699055; 98826880; 98905481

98699056 SP 9-13 MS4000 3.30 3 x 380-415 YES DOL Rp2 EN 1.4301 98699031; 98699056; 98809280; 98826881; 98826899

98699057 SP 9-16 MS4000 3.30 3 x 380-415 YES DOL Rp2 EN 1.4301 98699032; 98699057; 98809281; 98826882; 98826900

98699058 SP 9-18 MS4000 4.00 3 x 380-415 YES DOL Rp2 EN 1.4301 98699033; 98699058; 98809282; 98826883; 98826901

98699059 SP 9-21 MS4000 4.00 3 x 380-415 YES DOL Rp2 EN 1.4301 98699034; 98699059; 98809283; 98826884; 98826902

98699060 SP 9-23 MS4000 5.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699035; 98699038; 98699060; 98699066; 98826903; 98905485

98699061 SP 9-25 MS4000 5.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699036; 98699039; 98699061; 98699067; 98826904

98699062 SP 9-29 MS4000 5.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699037; 98699040; 98699062; 98699068; 98826905

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp2 dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

SP9

14 15

Page 9: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

98699313 SP 11-5 MS402 1.10 3 x 380-415 YES DOL Rp2 EN 1.4301 98699294; 98699298; 98699302; 98699313; 98826886; 99036962

98699314 SP 11-7 MS402 1.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699295; 98699299; 98699303; 98699314; 98826887; 99036973

98699315 SP 11-11 MS402 2.20 3 x 380-415 YES DOL Rp2 EN 1.4301 98699296; 98699300; 98699304; 98699315; 98826888

98699316 SP 11-15 MS4000 3.30 3 x 380-415 YES DOL Rp2 EN 1.4301 98699305; 98699316; 98809284; 98826889; 98826909

98699317 SP 11-20 MS4000 4.00 3 x 380-415 YES DOL Rp2 EN 1.4301 98699306; 98699317; 98809286; 98826890; 98826910

98699318 SP 11-24 MS4000 5.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699307; 98699309; 98699318; 98699329; 98826911

SP11

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp2 dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

16 17

Page 10: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

98699354 SP 14-6 MS402 1.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699337; 98699340; 98699343; 98699354; 98826892; 98905496

98699355 SP 14-8 MS402 2.20 3 x 380-415 YES DOL Rp2 EN 1.4301 98699338; 98699341; 98699344; 98699355; 98826893; 98905499

98699356 SP 14-11 MS4000 3.30 3 x 380-415 YES DOL Rp2 EN 1.4301 98699345; 98699356; 98809287; 98826895; 98826914; 98905501

98699357 SP 14-13 MS4000 3.30 3 x 380-415 YES DOL Rp2 EN 1.4301 98699346; 98699357; 98809288; 98826896; 98826915

98699358 SP 14-15 MS4000 4.00 3 x 380-415 YES DOL Rp2 EN 1.4301 98699347; 98699358; 98809289; 98826897; 98826916; 98905502

98699359 SP 14-17 MS4000 4.00 3 x 380-415 YES DOL Rp2 EN 1.4301 98699348; 98699359; 98809290; 98826898; 98826917

98699360 SP 14-20 MS4000 5.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699349; 98699351; 98699360; 98699371; 98826918; 98905503

98699361 SP 14-23 MS4000 5.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98699350; 98699352; 98699361; 98699372; 98826919

98711397 SP 14-27 MS4000 7.50 3 x 380-415 YES DOL Rp2 EN 1.4301 98711397; 98711398; 98711400; 98826920

SP14

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp2 dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

18 19

Page 11: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

12A01901 SP 17-1 MS402 0.55 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01001; 12A01801; 12A01901; 12A02101; 12A02401

12A01902 SP 17-2 MS402 1.10 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01002; 12A01802; 12A01902; 12A02102; 12A02402

12A01903 SP 17-3 MS402 2.20 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01003; 12A01803; 12A01903; 12A02103; 12A02403

12A01904 SP 17-4 MS402 2.20 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01004; 12A01804; 12A01904; 12A02104; 12A02404

12A01905 SP 17-5 MS4000 3.30 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01005; 12A01805; 12A0190512A01906 SP 17-6 MS4000 4.00 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01006; 12A01806; 12A0190612A01907 SP 17-7 MS4000 4.00 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01007; 12A01807; 12A01907

12A01908 SP 17-8 MS4000 5.50 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01008; 12A01808; 12A01908; 12AA1008; 12AA1808; 12AA1908

12A01909 SP 17-9 MS4000 5.50 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01009; 12A01809; 12A01909; 12AA1009; 12AA1809; 12AA1909

12A01910 SP 17-10 MS4000 5.50 3 x 380-415 YES DOL RP2 1/2 EN 1.4301 12A01010; 12A01810; 12A01910; 12AA1010; 12AA1810; 12AA1910

12A01912 SP 17-12 MS6000 7.5 3 x 380-415 NO DOL RP2 1/2 EN 1.4301 12A01012; 12A01812; 12A01912; 12AA1812; 12AA1912

12A01927 SP 17-27 MS6000 15 3 x 380-415 NO DOL RP2 1/2 EN 1.4301 12A01027; 12A01827; 12A01927

SP17

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp2 dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

20 21

Page 12: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

13A01901 SP 30-1 MS402 1.10 3 x 380-415 YES DOL RP3 EN 1.4301 13A01001; 13A01801; 13A01901; 13A02101; 13A02401

13A01902 SP 30-2 MS402 2.20 3 x 380-415 YES DOL RP3 EN 1.4301 13A01002; 13A01802; 13A01902; 13A02102; 13A02402

13A01903 SP 30-3 MS4000 3.30 3 x 380-415 YES DOL RP3 EN 1.4301 13A01003; 13A01803; 13A0190313A01903 SP 30-3 MS4000 3.30 3 x 380-415 YES DOL RP3 EN 1.4301 13A01003; 13A01803; 13A0190313A01904 SP 30-4 MS4000 4.00 3 x 380-415 YES DOL RP3 EN 1.4301 13A01004; 13A01804; 13A01904

13A01905 SP 30-5 MS4000 5.50 3 x 380-415 YES DOL RP3 EN 1.4301 13A01005; 13A01805; 13A01905; 13AA1005; 13AA1805; 13AA1905

13A01906 SP 30-6 MS4000 5.50 3 x 380-415 YES DOL RP3 EN 1.4301 13A01006; 13A01806; 13A01906; 13AA1006; 13AA1806; 13AA1906

13A01907 SP 30-7 MS6000 7.5 3 x 380-415 NO DOL RP3 EN 1.4301 13A01007; 13A01807; 13A01907; 13AA1807; 13AA1907

13AA1908 SP 30-8 MS4000 7.50 3 x 380-415 YES DOL RP3 EN 1.4301 13A01008; 13A01808; 13A01908; 13AA1808; 13AA1908

13A01908 SP 30-8 MS6000 7.50 3 x 380-415 NO DOL RP3 EN 1.4301 13A01008; 13A01808; 13A01908; 13AA1808; 13AA1908

13A01909 SP 30-9 MS6000 9.2 3 x 380-415 NO DOL RP3 EN 1.4301 13A01009; 13A01809; 13A0190913A01910 SP 30-10 MS6000 9.2 3 x 380-415 NO DOL RP3 EN 1.4301 13A01010; 13A01810; 13A0191013A01911 SP 30-11 MS6000 9.2 3 x 380-415 NO DOL RP3 EN 1.4301 13A01011; 13A01811; 13A0191113A01912 SP 30-12 MS6000 11 3 x 380-415 NO DOL RP3 EN 1.4301 13A01012; 13A01812; 13A0191213A01913 SP 30-13 MS6000 11 3 x 380-415 NO DOL RP3 EN 1.4301 13A01013; 13A01813; 13A0191313A01917 SP 30-17 MS6000 15 3 x 380-415 NO DOL RP3 EN 1.4301 13A01017; 13A01817; 13A0191713A16917 SP 30-17 MS6000 15 3 x 380-415 NO SD RP3 EN 1.4301 13A16017; 13A1691713A01926 SP 30-26 MS6000 22 3 x 380-415 NO DOL RP3 EN 1.4301 13A01026; 13A01826; 13A0192613A16926 SP 30-26 MS6000 22 3 x 380-415 NO SD RP3 EN 1.4301 13A16026; 13A1692613A16935 SP 30-35 MS6000 30 3 x 380-415 NO SD RP3 EN 1.4301 13A16035; 13A16935

SP30

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp3 dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

22 23

Page 13: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

15A21901 SP 46-1 MS402 2.20 3 x 380-415 YES DOL RP3 EN 1.4301 15A01001; 15A01801; 15A01901; 15A21001; 15A21801; 15A21901

15A219D2 SP 46-2-BB MS402 2.20 3 x 380-415 YES DOL RP3 EN 1.4301 15A010D2; 15A018D2; 15A019D2; 15A210D2; 15A218D2; 15A219D2

15A21902 SP 46-2 MS4000 3.30 3 x 380-415 YES DOL RP3 EN 1.4301 15A01002; 15A01802; 15A01902; 15A21002; 15A21802; 15A21902

15A219A3 SP46-3-1A MS4000 4.00 3 x 380-415 YES DOL RP3 EN 1.4301

15A219F3 SP 46-3-C MS4000 4.00 3 x 380-415 YES DOL RP3 EN 1.4301 15A010F3; 15A018F3; 15A019F3; 15A210F3; 15A218F3; 15A219F3

15A21903 SP 46-3 MS4000 5.50 3 x 380-415 YES DOL RP3 EN 1.4301

15A01003; 15A01803; 15A01903; 15A21003; 15A21803; 15A21903; 15AA1003; 15AA1803; 15AA1903; 15AC1003; 15AC1803; 15AC1903

15A219F4 SP 46-4-C MS4000 5.50 3 x 380-415 YES DOL RP3 EN 1.4301

15A010F4; 15A018F4; 15A019F4; 15A210F4; 15A218F4; 15A219F4; 15AA10F4; 15AA18F4; 15AA19F4; 15AC10F4; 15AC18F4; 15AC19F4

15A21904 SP 46-4 MS6000 7.50 3 x 380-415 NO DOL RP3 EN 1.4301

15A01004; 15A01804; 15A01904; 15A21004; 15A21804; 15A21904; 15AA1804; 15AA1904; 15AC1804;

15AC1904

15A21905 SP 46-5 MS6000 7.50 3 x 380-415 NO DOL RP3 EN 1.4301

15A01005; 15A01805; 15A01905; 15A21005; 15A21805; 15A21905; 15AA1805; 15AA1905; 15AC1805;

15AC1905

15A21906 SP 46-6 MS6000 9.2 3 x 380-415 NO DOL RP3 EN 1.4301 15A01006; 15A01806; 15A01906; 15A21006; 15A21806; 15A21906

15A21907 SP 46-7 MS6000 11 3 x 380-415 NO DOL RP3 EN 1.4301 15A01007; 15A01807; 15A01907; 15A21007; 15A21807; 15A21907

15A21908 SP 46-8 MS6000 13 3 x 380-415 NO DOL RP3 EN 1.4301 15A01008; 15A01808; 15A01908; 15A21008; 15A21808; 15A21908

15A21909 SP 46-9 MS6000 15 3 x 380-415 NO DOL RP3 EN 1.4301 15A01009; 15A01809; 15A01909; 15A21009; 15A21809; 15A21909

15A21910 SP 46-10 MS6000 15 3 x 380-415 NO DOL RP3 EN 1.4301 15A01010; 15A01810; 15A01910; 15A21010; 15A21810; 15A21910

15A36910 SP 46-10 MS6000 15 3 x 380-415 NO SD RP3 EN 1.4301 15A16010; 15A16910; 15A36010; 15A36910

15A21912 SP 46-12 MS6000 18.5 3 x 380-415 NO DOL RP3 EN 1.4301 15A01012; 15A01812; 15A01912; 15A21012; 15A21812; 15A21912

15A36912 SP 46-12 MS6000 18.5 3 x 380-415 NO SD RP3 EN 1.4301 15A16012; 15A16912; 15A36012; 15A36912

15A21915 SP 46-15 MS6000 22 3 x 380-415 NO DOL RP3 EN 1.4301 15A01015; 15A01815; 15A01915; 15A21015; 15A21815; 15A21915

15A36915 SP 46-15 MS6000 22 3 x 380-415 NO SD RP3 EN 1.4301 15A16015; 15A16915; 15A36015; 15A36915

15A21917 SP 46-17 MS6000 26 3 x 380-415 NO DOL RP3 EN 1.4301 15A00417; 15A01817; 15A01917; 15A20417; 15A21817; 15A21917

15A36917 SP 46-17 MS6000 26 3 x 380-415 NO SD RP3 EN 1.4301 15A16017; 15A16917; 15A36017; 15A36917

15A21920 SP 46-20 MS6000 30 3 x 380-415 NO DOL RP3 EN 1.4301 15A00420; 15A01820; 15A01920; 15A20420; 15A21820; 15A21920

15A36920 SP 46-20 MS6000 30 3 x 380-415 NO SD RP3 EN 1.4301 15A16020; 15A16920; 15A36020; 15A36920

SP46

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp3 dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

24 25

Page 14: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Product Number in

stockDescription Motor P2

[kW] VoltagePlug for

drop cable

Startform Pump Discharge Material Pumps with similar performance

14A01908 SP 60-8 MS6000 15 3 x 380-415 NO DOL RP4 EN 1.4301 14A01008; 14A01808; 14A01908; 14A21008; 14A21808; 14A21908

14A16908 SP 60-8 MS6000 15 3 x 380-415 NO SD RP4 EN 1.4301 14A16008; 14A16908; 14A36008; 14A36908

14A01910 SP 60-10 MS6000 18.5 3 x 380-415 NO DOL RP4 EN 1.4301 14A01010; 14A01810; 14A01910; 14A21010; 14A21810; 14A21910

14A16910 SP 60-10 MS6000 18.5 3 x 380-415 NO SD RP4 EN 1.4301 14A16010; 14A16910; 14A36010; 14A36910

14A01912 SP 60-12 MS6000 22 3 x 380-415 NO DOL RP4 EN 1.4301 14A01012; 14A01812; 14A01912; 14A21012; 14A21812; 14A21912

14A16912 SP 60-12 MS6000 22 3 x 380-415 NO SD RP4 EN 1.4301 14A16012; 14A16912; 14A36012; 14A36912

14A01915 SP 60-15 MS6000 26 3 x 380-415 NO DOL RP4 EN 1.4301 14A00415; 14A01815; 14A01915; 14A20415; 14A21815; 14A21915

14A16915 SP 60-15 MS6000 26 3 x 380-415 NO SD RP4 EN 1.4301 14A16015; 14A16915; 14A36015; 14A36915

14A01917 SP 60-17 MS6000 30 3 x 380-415 NO DOL RP4 EN 1.4301 14A00417; 14A01817; 14A01917; 14A20417; 14A21817; 14A21917

14A16917 SP 60-17 MS6000 30 3 x 380-415 NO SD RP4 EN 1.4301 14A16017; 14A16917; 14A36017; 14A36917

All pumps and motors are in stainless steel EN 1.4301 (AISI 304) and have a threaded Rp4 dischargeSee Motor Data, page 28 and pages 29 to 33 for selection of drop cable and connection kit

SP60

26 27

Page 15: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Type Size kW (kW)

Full-load current,

In (A)

Motor efficiency [%] Power factorIst/In

Diameter [mm]

Length [mm]

Weight [kg]η50 % η75 % η100 % Cos φ

50 %Cos φ 75 %

Cos φ 100 %

MS402 4" 0.37 3.95 48.0 54.0 57.0 0.58 0.68 0.77 3.4* 95 256 6.8MS402 4" 0.55 5.80 49.5 56.5 59.5 0.52 0.65 0.74 3.5* 95 291 8.2MS402 4" 0.75 7.45 52.0 58.0 60.0 0.57 0.69 0.79 3.6* 95 306 8.9MS402 4" 1.1 7.30 62.0 69.5 72.5 0.99 0.99 0.99 4.3* 95 346 10.5MS402 4" 1.5 10.2 56.5 66.5 71.0 0.91 0.96 0.98 3.9 95 346 11.0MS4000(R) 4" 2.2 14.0 67.0 73.0 75.0 0.91 0.94 0.96 4.4 95 576 21.0

Type Size kW (kW)

Full-load current,

In (A)

Motor efficiency [%] Power factorIst/In

Diameter [mm]

Length [mm]

Weight [kg]η50 % η75 % η100 % Cos φ

50 %Cos φ 75 %

Cos φ 100 %

MS402 4" 0.37 1.40 51.0 59.5 64.0 0.44 0.55 0.64 3.7 95 226 5.5MS402 4" 0.55 2.20 48.5 57.0 64.0 0.42 0.52 0.64 3.5 95 241 6.3MS402 4" 0.75 2.30 64.0 69.5 73.0 0.50 0.62 0.72 4.7 95 276 7.7MS4000R 4" 0.75 1.84 68.1 71.6 72.8 0.69 0.79 0.84 4.9 95 401 13.0MS402 4" 1.1 3.40 62.5 69.0 73.0 0.47 0.59 0.72 4.6 95 306 8.9MS4000R 4" 1.1 2.75 70.3 74.0 74.4 0.62 0.74 0.82 5.1 95 416 14.0MS402 4" 1.5 4.20 68.0 73.0 75.0 0.50 0.64 0.75 5.0 95 346 10.5MS4000R 4" 1.5 4.00 69.1 72.7 73.7 0.55 0.69 0.78 4.3 95 416 14.0MS402 4" 2.2 5.50 72.5 75.5 76.0 0.56 0.71 0.82 4.7 95 346 11.9MS4000(R) 4" 2.2 6.05 67.9 73.1 74.5 0.49 0.63 0.74 4.5 95 456 16.0MS4000(R) 4" 3.0 7.85 71.5 74.5 75.2 0.53 0.67 0.77 4.5 95 496 17.0MS4000(R) 4" 4.0 9.60 77.3 78.4 78.0 0.57 0.71 0.80 4.8 95 576 21.0MS4000(R) 4" 5.5 13.0 78.5 80.1 79.8 0.57 0.72 0.81 4.9 95 676 26.0MS4000(R) 4" 7.5 18.8 75.2 78.2 78.2 0.52 0.67 0.78 4.5 95 776 31.0MS6000(R) 6" 5.5 13.6 78.0 80.0 80.5 0.55 0.67 0.77 4.4 139.5 544 35.5MS6000(R) 6" 7.5 17.6 81.5 82.0 82.0 0.60 0.73 0.80 4.3 139.5 574 37.0MS6000(R) 6" 9.2 21.8 78.0 80.0 79.5 0.61 0.73 0.81 4.6 139.5 604 42.5MS6000(R) 6" 11 24.8 82.0 83.0 82.5 0.65 0.77 0.83 4.7 139.5 634 45.5MS6000(R) 6" 13 30.0 82.5 83.5 82.0 0.62 0.74 0.81 4.6 139.5 664 48.5MS6000(R) 6" 15 34.0 82.0 83.5 83.5 0.64 0.76 0.82 5.0 139.5 699 52.5MS6000(R) 6" 18.5 42.0 83.5 84.5 83.5 0.62 0.73 0.81 5.1 139.5 754 58.0MS6000(R) 6" 22 48.0 84.5 85.0 83.5 0.67 0.77 0.84 5.0 139.5 814 64.0MS6000(R) 6" 26 57.0 84.5 85.0 84.0 0.66 0.77 0.84 4.9 139.5 874 69.5MS6000(R) 6" 30 66.5 84.5 85.0 84.0 0.64 0.77 0.83 4.9 139.5 944 77.5

1 X 230 V, 50 HZ, SUBMERSIBLE MOTORS “MS”

3 X 400 V, 50HZ, SUBMERSIBLE MOTORS “MS”

DROP CABLE CALCULATOR

For easy and safe selection of your drop cable, please go to Grundfos Product Center. On the front page click “Tools” and select “Cable Calculator”. On page 28 in this folder you can find the needed motor current for making the cable calculation and go to pages 29 to 33 for selecting the drop cable and cable connection set.

28 29

Page 16: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Motor type DescriptionCable

diameter(mm²)

Max motor size (kW) at 3% voltage

drop 3 x 400 V

Max motor size (kW) at 3% voltage

drop 1 x 230 V

Cable length

(m)

Plug material

Product No.

Extension drop cable for pumps with MS402 or MS4000 motor

Cable with plug for connection to motor cable

with plug. The drop cable has a free cable

end

4 x 1.5mm2

7.5 1.5 15

1.4401

0079H0017.5 1.5 20 0079H0027.5 1.1 25 0079H0035.5 0.75 30 0079H0044.0 40 0079H0054.0 50 0079H0062.2 70 0079H008

4 x2.5mm2

7.5 1.5 15 0079H0217.5 1.5 20 0079H0227.5 1.5 25 0079H0237.5 1.5 30 0079H0247.5 1.1 40 0079H0255.5 0.55 50 0079H0264 70 0079H028

4 x 4mm2

7.5 1.5 15 0079H0417.5 1.5 20 0079H0427.5 1.5 25 0079H0437.5 1.5 30 0079H0447.5 1.5 40 0079H0457.5 1.5 50 0079H0467.5 - 70 0079H048

Motor typeCable

diameter(mm²)

Outside cable

diameter (mm)

Max motor size (kW) at 3% voltage

drop 3 x 400 V

DOL

Max motor size (kW) at 3% voltage

drop 3 x 400 V

Star/Delta

Weight(kg/m)

Cable length

(m)

Product No.

TML-B four lead round cable for MS6000

4 x 1.5 mm² 10.7 0.17 per m 00ID40634 x 2.5 mm² 12.6 0.24 per m 00ID40644 x 4.0 mm² 14.4 0.34 per m 00ID4065

4 x 6.0 mm² 16.2 22 kW @ max 40 m 0.46 per m 00ID4066

4 x 10.0 mm² 21.9 30 kW @ max 50 m 0.8 per m 00ID4067

4 x 16.0 mm² 26.2 30 kW @ max 65 m 1.17 per m 00ID4068

4 x 25.0 mm² 30.2 30 kW @ max 100 m 1.65 per m 00ID4069

4 x 35.0 mm² 24.5 30 kW @ max 135 m

30 kW @ max 250 m 2.2 per m 96432949

4 x 50.0 mm² 51.4 30 kW @ max 200 m 3.26 per m 96432950

4 x 70.0 mm² 48 4.3 per m 96432951

EXTENSION DROP CABLES (EXCL. ITALY) FOR MS402 AND MS4000

DROP CABLE FOR MS6000 For star/delta motors two cables must be ordered

EXTENSION DROP CABLES, EUROPE, EXCL. ITALY

• Ordering procedure for pumps with MS402 & MS4000 motors

The pumps in stock with MS402 and MS4000 motors all have a motor cable with two plugs. When ordering a pump and an extension drop cable with plug:

If the cable is to be connected (the two plugs mounted together), add the following text as a shipping instruction in the sales order header:“Connection is needed/packing in one coli”

• Ordering procedure for pumps with MS6000 motors

The pumps in stock with MS6000 motors all have a motor cable without plug.When ordering a pump and a drop cable:

The drop cable number is per meter, so the length of the cable is ordered by specifying the number of cable units (meters) required.

If the cable is to be connected, the appropriate connection set must be ordered. Each connection set is available with two numbers – either mounted or delivered as a separate non-mounted set.

If the mounted set is ordered, the drop cable is connected to the pump and nothing should be written on the sales order header.

30 31

Page 17: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Description For cablediameter (mm²) Connectors Product No.

For Drop cables, type TML-B and for all drop cables with Italian D.M.174 certificate

4 x 1.5 – 6.0 mm²

With pressed connections for up to

four leads

Not mounted * 00116251Mounted* 00116451

4 x 1.5 – 6.0 mm²Not mounted * 00116252

Mounted* 00116452

4 x 1.5 – 6.0 mm²Not mounted * 00116255

Mounted* 00116455

For ItalyCable

diameter(mm²)

Outside cable

diameter (mm)

Max motor size (kW) at 3% voltage

drop 3 x 400 V

DOL

Max motor size (kW) at 3% voltage

drop 1 x 230 V DOL

Weight(kg/m)

Cable length

(m)

Product No.

For all motor types. A connection set, type KM must also be ordered

4 x 1.5 mm² 10.4 Max 100 m @ 1.5 kW

Max 35 m @ 0.55 kW 0.127 per m 99067042

4 x 2.5 mm² 12.5 Max 100 m @ 2.2 kW

Max 55 m @ 0.55 kW 0.194 per m 99067053

4 x 4.0 mm² 13.9 Max 100 m @ 4.0 kW

Max 50 m @ 1.50 kW 0.268 per m 99067055

4 x 6.0 mm² 15.8 Max 100 m @ 5.5 kW

Max 80 m @ 1.50 kW 0.371 per m 99067056

4 x 10.0 mm² 21.5 Max 100 m @ 11 kW 0.646 per m 99067057

4 x 16.0 mm² 24.8 Max 100 m @ 18.5 kW 0.959 per m 99067058

4 x 25.0 mm² 30.1 Max 100 m @ 30 kW 1.430 per m 99067059

CONNECTION SETS FOR DROP CABLESFor star/delta motors two connection sets must be ordered

* The drop cable can be delivered mounted to the motor cable on the pump by means of the connection set

• Ordering procedure for pumps with MS402, MS4000 & MS600 motors for Italy (cables with D.M.174-certificate)

When ordering a pump and a drop cable for Italy:

The drop cable number is per meter, so the length of the cable is ordered by specifying the number of cable units (meters) required.

If the cable is to be connected, the appropriate connection set must be ordered. Each connection set is available with two numbers – either mounted or delivered as a separate non-mounted set.

If the mounted set is ordered, the drop cable is connected to the pump and nothing should be written on the sales order header.

DROP CABLE WITH ITALIAN D.M.174 CERTIFICATE For star/delta motors two connection sets must be ordered

DROP CABLES FOR ITALY

32 33

Page 18: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

34 35

Page 19: GRUNDFOS SP SUBMERSIBLE BOREHOLE PUMPS

Alth

ough

we

have

don

e ou

r utm

ost t

o en

sure

the

accu

racy

of t

his g

uide

, Gru

ndfo

s ca

nnot

be

held

acc

ount

able

for p

oten

tial e

rror

s or t

ypos

and

will

not

cove

r any

cost

s ca

used

by

faul

ty o

r mis

lead

ing

info

rmat

ion.

0316

/Wat

er U

tility

/121

46 B

rand

Box

GRUNDFOS Holding A/SPoul Due Jensens Vej 7DK-8850 BjerringbroTel: +45 87 50 14 00www.grundfos.com


Recommended