Page 1: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

GT, GTS, GTX and AccuTest Turbine Gas Meters

Technical Bulletin

nkohart
Typewritten Text
Distributed By: IMAC Systems, Inc. 90 Main Street / PO Box 1605 Tullytown, PA. 19007 Tel: 800 955-4427 / 215 946-2200 Fax: 215 943-2984 www.imacsystems.com
nkohart
Typewritten Text
nkohart
Typewritten Text
Page 2: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

GT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter

The turbine meters are designed to accurately measure natural gas, air, nitrogen, carbon dioxide, propane vapor, and other non-corrosive gases for large volume commercial and industrial uses.

General InformationMeters are available in sizes ranging from 3" up to 12". Inlet pressures up to 1480 PSIG. Operating temperature range is -40°F to 140°F. (-40°C to 60°C). Maximum flow rates at 7" Water Column pressure (.60 Specific Gravity Gas) are:

3" – 10,000 SCFH

4" – 18,000 SCFH

6" – 35,000 SCFH

8" – 60,000 SCFH

12" – 150,000 SCFH

Meters meet manufacturing standards as specified in ANSI/ASME/AGA Report Number 7.

FeaturesMaximum allowable operating pressures (MAOP) – from 175 PSIG up to 1480 PSIG.

Body Materials – Cast aluminum, cast steel, or steel depending on pressure rating.

English or metric units of measurement.

Common gear train for 3", 4", 6" and 8" meter sizes thereby reducing spare parts inventory.

Interchangeable pre-calibrated measurement cartridges allow for easy maintenance.

High efficiency inlet Flo-Guide conditioners minimize the effects of flow disturbances in short coupled installations.

GTX model utilizes permanently lubricated bearings for maintenance free use.

AccuTest model incorporates two independent measuring cartridges in one housing, both calibrated to allow proving the meter while in service with ATP software.

OptionsExtended Capacity Ratings

Standard capacity ranges available for all sizes and models. The 4", 6", and 8" GTS and AccuTest turbine meters can utilize a 30° rotor to increase the capacity over the standard 45° rotor.

Rotor Materials

Available in either plastic or metal (Metal must be used for high frequency RF pulser).

Volume Registration Outputs

The turbine meters come with several outputs: mechanical drive with index, mechanical drive with no index or mechanical drive and electronic (RF, RVP, MFP) pulse output.

Applications

Pressure Ratings

Indexes

Available in either English or metric units of volume with circle type or odometer type indexes.

Pulse Outputs

Pulsers can be furnished with the meter.

30º Rotor 45º Rotor

Model DescriptionGT Basic turbine meter, downstream rotor, integral Flo-Guides®, flush-type lubrication

system cleans main bearings while meter is in operation, available in 3" and 12".

GTS Basic turbine meter, pre-machined housings to allow upgrade to AccuTest self-test model, flush-type lubrication system cleans main bearings while meter is in operation, both inlet and outlet Flo-Guides, available in 4", 6" and 8".

GTX Economic turbine meter, permanently lubricated main bearings, inlet Flo-Guide®, available in 4", 6", and 8".

AccuTest Self-proving turbine meter, both inlet and outlet Flo-Guides®, flush-type lubrication system cleans main bearings while meter is in operation, two high frequency RF-type pulsers, secondary reference cartridge, aluminum main and reference rotors, available in 4", 6", and 8" pipe sizes.

3" 4" 6" 8" 12"45° Plastic 45° Plastic 45° Plastic 45° Plastic 45° Plastic

45° Metal 45° Metal 45° Metal

30° Metal 30° Metal 30° Metal

Size MAOP MaterialPSIG (bar) Housing Top

3"275 (19) Aluminum NA

1480 (100) Steel NA

4"175 (12) Aluminum Aluminum740 (50) Cast Steel Steel

1480 (100) Cast Steel Steel

6"175 (12) Aluminum Aluminum740 (50) Cast Steel Steel

1480 (100) Cast Steel Steel

8"175 (12) Aluminum Aluminum740 (50) Cast Steel Steel

1480 (100) Cast Steel Steel

12"

175 (12) Steel Aluminum275 (19) Steel Steel740 (50) Steel Steel

1480 (100) Steel Steel

3" 4" 6" 8" 12"Low Frequency

Remote Volume Pulser (RVP)

Medium Frequency

GT Only All Models GT Only

RF Pulser

N/A GTS and AccuTest N/A

Page 3: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

GT, GTS, GTX and AccuTest Turbine Gas Meters 03 Elster American Meter

Extended Width (E-Class) Housing

The 4", 6" and 8" turbine meters are available with an extended width housing. The 4" E-Class is available in all pressure ratings while the 6" and 8" E-Class Housings are available in either 175 or 740 PSIG working pressures.

Straightening Vanes

Straightening Vanes are recommended by the A.G.A. Report No. 7 as a means to condition the gas flow to a normal pattern, enabling accurate measurement by the downstream turbine meter.

Restrictor Plate

Restrictor plates limit the flow rate through the meter and prevent overspeeding of the rotor. They are normally installed 5 pipe diameters downstream of the meter between flanges.

Lubrication

Turbine meters require routine maintenance, including lubrication, to insure measurement accuracy and enhance the service life of the meter. Two types of lubrication pump kits are available depending on the working pressure of the meter. For meters operating up to 500 PSIG, a plunger-type pump is available (Part Number 93723K002). For meters operating over 500 PSIG, use the single speed hydraulic hand pump (Part Number 93723K001).

AccuTest Field Prover

The AccuTest Field Prover includes the sensor cables, signal conditioner in a case, DAQ card, computer interface cable, and software program.

Accuracy Curves

The accuracy of the turbine meter can be determined by low, medium, and high-pressure test facilities.

Low Pressure

- 350 cubic foot Bell Prover - Large Sonic Nozzle provers - 5 point accuracy curve standard

Medium Pressure

- 120 PSIG recirculating air test loop - Master turbine meters used as reference - 6 point accuracy curve standard - (30 PSIG to 120 PSIG – air)

High Pressure

- Pressures up to 1480 PSIG - Master turbine meters or sonic nozzles used as reference - 6 point accuracy curve standard

All facilities are available for recertification of existing meters.

Flow Computer RF Interface Kit

This kit allows the use of a single RF sensor to detect movement of the rotor.

Page 4: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

Theory of Operation

Gas measurement in the U.S. and around the world is dominated by diaphragm, rotary, turbine, and orifice meters. Each serves a different segment of the gas industry and each has its own set of advantages and disadvantages.

These four main types of meters can be broken into two distinct categories: positive displacement, and inferential. Diaphragm and rotary meters fall into the positive displacement group because they have well-defined measurement compartments that alternately fill and empty as the meter rotates. By knowing the volume displaced in each meter revolution and by applying the proper gear ratio, the meter will read directly in cubic feet or cubic meters.

Turbine and orifice meters have no measurement compartments to trap and then release the gas. These meters are categorized as inferential meters in that the volume passed through them is "inferred" by something else observed or measured. In the orifice meter the volumes are determined by knowing the inlet pressure, differential pressure, plate size, and piping characteristics, all of which "infer" the flow rates that in turn can be integrated over time to provide the volume.

Turbine meters, also called velocity meters, "infer" the volume of gas passing through them by measuring the velocity of the gas stream. Gas moving through the meter impinges on rotor blades resulting in a rotational speed that is proportional to the flow rate. The volume is determined by counting the number of meter rotations.

As defined in A.G.A. Report #7, the turbine meter consists of three basic components:

1. The body which houses all of the parts and physically contains the gas pressure.

2. The measuring mechanism consisting of the rotor, rotor shaft, bearings, and necessary supporting structure.

3. The output and readout device which may be either a mechanical drive to transmit the indicated meter revolutions outside the body for uncorrected volume registrations or for electrical pulse meters, it would be the pulse detector system and all electrical connections needed to transmit the pulses outside.

Gas entering the meter increases in velocity as it flows through the annular passage formed by the nose cone or upstream stator and the interior of the body. The movement of the gas over the angled rotor blades exerts a force to the rotor causing it to rotate. The ideal rotational speed of the rotor is directly proportional to the flow rate of the gas. The actual rotational speed is a function of the annular passageway size and shape, and rotor design. It is also dependent on the load that is imposed due to internal mechanical friction, fluid drag, external loading, and gas density.

A.G.A. Report #7 was written to provide recommendations as to the correct method for installing turbine meters, using their associated corrective factors, and meeting the operating requirements that pertain to axial flow type meters. Since the turbine meter is a velocity-measuring device, consideration should be given to both the upstream and downstream piping to insure a uniform velocity distribution of the gas through the meter and the rotor by reducing jetting or swirl. Construction of the turbine meter is such so as to minimize minor flow distortions that could affect meter performance. See Figure 1.

The AccuTest turbine meter utilizes a second cartridge downstream of the first or main rotor. This rotor has vanes with a different blade angle and rotates in the opposite direction of the main rotor. Since both rotors are measuring the same flow rate of gas at the same temperature and pressure, then the output registration should be the same off of both rotors. In effect, the meter is a built-in transfer prover to continuously monitor its condition.

A laptop computer, with inputs from both rotor sensors, multiplies the ratio of pulse frequencies by the ration of the calibration (K) factors to compute meter accuracy.

Accuracy = (Frequency of main rotor)/(Frequency of reference rotor) times (K Factor of reference rotor)/(K Factor of main rotor)

GT, GTS, GTX and AccuTest Turbine Gas Meters 04 Elster American Meter

Figure 1 A Optional Valve

B 10 Nominal Pipe Diameters

C 5 Nominal Pipe Diameters

D Straightening Vanes

E Turbine Meter

F Temperature Well (Downstream)

A A

B C

CDE

F

Page 5: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

Material SpecificationsHousing - Aluminum for pressures up to 275 PSIG. Cast Steel for pressures greater than 275 PSIG. Steel for all 12" housings. 3" housing is clamped (wafer style) between ANSI flanges. 4" through 12" housings are ANSI flanged.

Inlet Flo-Guide® - Black Stanyl TW241F10. 12" GT uses an aluminum Flo-Guide®.

Outlet Flo-Guide® - Black Stanyl TW241F10. Not available on GTX meter. 12" GT uses an aluminum Flo-Guide®.

Rotor -

Angle Material Used on

45° Plastic All45° Aluminum 4", 6" & 8"30° Aluminum 4", 6" & 8"

Rotor is located downstream on 3" GT and 12" GT meters. GT and GTX meters are only available with a 45° plastic rotor. GTS meters available with a 45° or 30° rotor in either plastic or aluminum.

Flush-type Lubrication System. System has an internal reservoir that continuously lubricates the main rotor shaft while in operation. Available on GT, GTS and AccuTest meters.

Intermediate Gears - Brass, Designed for each specific meter size and rotor angle.

Gear Train Assembly - Delrin gears, Provides mechanical output drive to an index or corrector.

1/4" NPT Drain Plug - Steel, zinc plated and yellow chromate.

Magnetic Drive Interface - Isolates high pressure components eliminating the need for seals.

Top Plate - Aluminum, for working pressures of 125 and 275 PSIG. Steel, for working pressures of 740 and 1480 PSIG.

Reference Rotor - Aluminum, AccuTest meter only.

RF Sensor Assembly - Stainless Steel, Standard on AccuTest, optional on 4", 6" and 8" GTS meters.

Pressure Tap - Senses pressure at the rotor. AccuTest and GTS meters only.

Lubrication Fitting - GT, GTS and AccuTest meters only.

GT, GTS, GTX and AccuTest Turbine Gas Meters 05 Elster American Meter

A

B

C

D

E

F

G

H

I

J

K

L

M

N

K

L

M

D

N

G CJ

I

F

B

A

D H E

Page 6: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

GT, GTS, GTX and AccuTest Turbine Gas Meters 06 Elster American Meter

GT, GTS, GTX and AccuTest Turbine Meters Capacity Performance

3" GT, Output Drive = 100 Cubic Feet, 45° Rotor

Note: Capacity Table values established @ base pressure of 14.73 PSIA and base temperature of 60°F; 0.60 specific gravity gas. Supercompressibility included.

3" GT, Output Drive = 1.0 Cubic Meters, 45° Rotor

Note: Capacity Table values established @ base pressure of 101.325 kPa and base temperature of 15°C. Supercompressibility included.

Line Pressure (PSIG)

Qmax MSCFH

Qmin MSCFH Range Qmax/Qmin Min. Actual Flow Rate

MACFH Press. Drop in W.C.

0.25 10 0.8 12 0.83 4.5

5 13 1.0 14 0.73 6.010 17 1.1 15 0.65 7.515 20 1.2 17 0.59 9.020 23 1.3 18 0.55 10.525 27 1.4 20 0.51 12.150 44 1.8 25 0.40 19.775 61 2.1 30 0.34 27.3100 79 2.4 33 0.30 35.0125 97 2.6 37 0.28 42.6150 114 2.9 40 0.30 50.2175 132 3.1 43 0.24 57.9200 150 3.3 46 0.23 65.5275 205 3.9 53 0.20 88.4300 224 4.0 55 0.19 96.1400 300 4.7 64 0.17 127.0500 379 5.3 71 0.15 157.0600 460 5.9 78 0.14 188.0700 544 6.5 84 0.13 218.0800 630 7.1 89 0.13 249.0900 719 7.6 95 0.12 279.01000 810 8.1 100 0.12 310.0

1100 904 8.7 104 0.12 340.0

1200 1000 9.2 109 0.11 371.0

1300 1098 9.7 113 0.11 402.0

1400 1197 10.2 118 0.11 432.0

Line Pressure (bar)

Line Pressure (kPa)

Qmax Sm3/h

Qmin Sm3/h Range Qmax/Qmin Min. Actual Flow Rate

Am3/h Press. Drop in mbar

0.02 2 284 24 12 23.5 11.30.30 30 365 27 14 21.0 14.30.70 70 482 31 16 18.5 18.81.00 100 559 33 17 16.8 22.12.00 200 841 41 21 13.8 33.13.00 300 1124 47 24 12.0 44.25.00 500 1694 58 29 9.8 66.37.00 700 2270 67 34 8.5 88.48.00 800 2559 72 36 8.1 99.59.00 900 2851 76 38 7.7 111.010.00 1000 3143 80 40 7.3 122.012.00 1200 3733 87 43 6.8 144.015.00 1500 4626 97 48 6.1 177.020.00 2000 6143 112 55 5.4 232.030.00 3000 9289 140 66 4.6 343.035.00 3500 10,912 153 72 4.3 398.040.00 4000 12,581 165 76 4.1 453.050.00 5000 16,031 188 85 3.7 564.060.00 6000 19,630 211 93 3.5 674.070.00 7000 23,387 233 100 3.3 785.080.00 8000 27,274 254 107 3.2 895.090.00 9000 31,287 275 114 3.1 1006.0100.00 10,000 35,478 296 120 3.0 1116.0

Page 7: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

GT, GTS, GTX and AccuTest Turbine Gas Meters 07 Elster American Meter

4" GTS and AccuTest, Output Drive = 100 Cubic Feet

Note: Capacity Table values established @ base pressure of 14.73 PSIA and base temperature of 60°F; 0.60 specific gravity gas. Supercompressibility included.

4" GTS and AccuTest, Output Drive = 1.0 Cubic Meters

Note: Capacity Table values established @ base pressure of 101.325 kPa and base temperature of 15°C. Supercompressibility included.

Line Pressure (PSIG)

45° Rotor 30° Rotor AccuTest Reference Rotor

Qmax MSCFH

Qmin MSCFH

Range Qmax/Qmin

Min. Actual Flow RateMACFH

Press. Drop in W.C.

Qmax MSCFH

Qmin MSCFH

Range Qmax/Qmin

Min. Actual Flow RateMACFH

Press. Drop in W.C.

Range Qmax/Qmin

Min. Actual Flow RateMACFH

0.25 18 1.2 15 1.20 2.4 23 1.9 12 1.92 3.9 10 1.805 24 1.4 17 1.06 3.2 30 2.2 14 1.65 5.2 12 1.5010 30 1.5 19 0.90 4.0 38 2.5 15 1.48 6.5 13 1.3815 36 1.7 21 0.85 4.8 46 2.7 17 1.36 7.8 14 1.2920 42 1.8 23 0.77 5.6 54 2.9 18 1.26 9.1 15 1.2025 48 2.0 25 0.75 6.4 62 3.1 20 1.18 10.5 17 1.0650 79 2.5 31 0.58 10.5 101 4.0 25 0.93 17.1 21 0.8675 111 3.0 37 0.50 14.6 141 4.8 30 0.79 23.7 25 0.72100 142 3.4 42 0.43 18.7 181 5.4 33 0.70 30.3 27 0.67125 174 3.8 46 0.40 22.7 222 6.0 37 0.64 36.9 31 0.58150 206 4.1 50 0.43 26.8 263 6.6 40 0.69 43.5 33 0.55175 238 4.4 54 0.34 30.9 304 7.1 43 0.55 50.2 36 0.50200 270 4.7 57 0.41 34.9 346 7.5 46 0.52 56.8 38 0.47275 370 5.6 66 0.28 47.2 472 8.9 53 0.45 76.6 44 0.41300 403 5.8 69 0.27 51.2 515 9.3 55 0.44 83.3 46 0.39400 540 6.8 80 0.24 67.5 690 10.8 64 0.39 110.0 53 0.34500 682 7.7 89 0.22 83.8 871 12.3 71 0.35 136.0 59 0.31600 828 8.5 97 0.21 100.0 1057 13.6 78 0.33 163.0 65 0.28700 978 9.4 104 0.19 116.0 1250 15.0 84 0.31 189.0 70 0.26800 1134 10.2 112 0.18 133.0 1449 16.2 89 0.29 216.0 74 0.24900 1294 10.9 118 0.18 149.0 1653 17.5 95 0.28 242.0 79 0.231000 1458 11.7 124 0.17 165.0 1864 18.7 100 0.27 269.0 83 0.221100 1627 12.5 130 0.17 182.0 2079 19.9 104 0.26 295.0 87 0.211200 1800 13.2 136 0.16 198.0 2300 21.1 109 0.26 322.0 91 0.201300 1976 13.9 142 0.16 214.0 2525 22.3 113 0.25 348.0 94 0.191400 2155 14.7 147 0.15 230.0 2754 23.4 118 0.24 375.0 98 0.18

Line Pressure

(bar)

Line Pressure

(kPa)

45° Rotor 30° Rotor AccuTest Reference Rotor

Qmax Sm3/h

Qmin Sm3/h

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

Press. Drop in mbar

Qmax Sm3/h

Qmin Sm3/h

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

Press. Drop in mbar

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

0.02 2 509 34 15 34 6.0 651 54.1 12 53.9 9.8 10 51.0

0.30 30 657 39 17 30 7.7 841 61.9 14 48.3 12.6 12 42.0

0.70 70 867 45 19 27 10.1 1109 71.4 16 42.6 16.4 13 39.0

1.00 100 1006 48 21 24 11.8 1287 76.4 17 38.7 19.3 14 36.0

2.00 200 1513 59 26 20 17.8 1935 93.7 21 31.7 29.0 17 30.0

3.00 300 2022 68 30 17 23.7 2587 108.5 24 27.5 38.7 20 25.0

5.00 500 3047 83 36 14 35.5 3897 133.5 29 22.5 58.0 24 21.0

7.00 700 4082 97 42 12 47.4 5221 154.9 34 19.6 77.4 28 18.0

8.00 800 4603 103 45 12 53.3 5887 164.6 36 18.5 87.0 30 17.0

9.00 900 5127 109 47 11 59.2 6558 174.0 38 17.6 96.7 32 16.0

10.00 1000 5654 114 49 11 65.1 7231 182.9 40 16.9 106.0 33 15.0

12.00 1200 6714 125 54 10 77.0 8587 199.8 43 15.6 126.0 36 14.0

15.00 1500 8320 140 60 9 94.7 10,641 223.2 48 14.1 155.0 40 13.0

20.00 2000 11,049 162 68 8 124.0 14,132 258.7 55 12.5 203.0 46 11.0

30.00 3000 16,707 201 83 7 184.0 21,368 321.9 66 10.5 300.0 55 9.2

35.00 3500 19,626 220 89 6 213.0 25,101 350.9 72 9.9 348.0 60 8.5

40.00 4000 22,628 237 95 6 243.0 28,941 379.1 76 9.4 397.0 63 8.1

50.00 5000 28,834 271 106 5 302.0 36,878 433.2 85 8.6 493.0 71 7.2

60.00 6000 35,306 303 116 5 361.0 45,155 485.0 93 8.1 590.0 77 6.6

70.00 7000 42,064 335 126 5 420.0 53,799 535.6 100 7.6 687.0 83 6.1

80.00 8000 49,054 366 134 5 480.0 62,740 584.8 107 7.3 783.0 89 5.7

90.00 9000 56,272 396 142 4 539.0 71,970 632.9 114 7.0 880.0 95 5.4

100.00 10,000 63,810 426 150 4 598.0 81,612 681.2 120 6.8 977.0 100 5.1

Page 8: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

GT, GTS, GTX and AccuTest Turbine Gas Meters 08 Elster American Meter

6" GTS and AccuTest, Output Drive = 100 Cubic Feet

Note: Capacity Table values established @ base pressure of 14.73 PSIA and base temperature of 60°F; 0.60 specific gravity gas. Supercompressibility included.

6" GTS and AccuTest, Output Drive = 1.0 Cubic Meters

Note: Capacity Table values established @ base pressure of 101.325 kPa and base temperature of 15°C. Supercompressibility included.

Line Pressure (PSIG)

45° Rotor 30° Rotor AccuTest Reference Rotor

Qmax MSCFH

Qmin MSCFH

Range Qmax/Qmin

Min. Actual Flow RateMACFH

Press. Drop in W.C.

Qmax MSCFH

Qmin MSCFH

Range Qmax/Qmin

Min. Actual Flow RateMACFH

Press. Drop in W.C.

Range Qmax/Qmin

Min. Actual Flow RateMACFH

0.25 35 1.9 18 1.94 3.3 50 3.3 15 3.34 6.7 10 3.505 46 2.2 21 1.69 4.4 66 3.8 17 2.90 8.9 12 2.9210 58 2.5 23 1.51 5.5 83 4.3 19 2.59 11.2 13 2.7015 70 2.8 25 1.38 6.6 100 4.7 21 2.36 13.5 14 2.5020 82 3.0 28 1.27 7.7 117 5.1 23 2.18 15.8 15 2.3325 94 3.2 29 1.19 8.8 134 5.5 25 2.03 18.1 17 2.0650 154 4.1 38 0.94 14.4 220 7.0 31 1.59 29.7 21 1.0775 215 4.8 44 0.80 20.0 307 8.3 37 1.34 41.4 25 1.40100 276 5.5 50 0.71 25.6 394 9.4 42 1.19 53.2 27 1.30125 338 6.1 55 0.64 31.2 483 10.5 47 1.07 65.0 31 1.13150 400 6.7 60 0.70 36.8 572 11.4 51 0.99 77.0 33 1.06175 463 7.2 65 0.56 42.4 661 12.3 55 0.92 89.0 36 0.97200 526 7.7 69 0.53 48.1 751 13.1 58 0.86 101.0 38 0.92275 719 9.0 80 0.46 64.9 1026 15.4 68 0.74 138.0 44 0.80300 784 9.4 83 0.44 70.5 1120 16.2 71 0.70 151.0 46 0.76400 1050 11.0 95 0.39 92.9 1500 18.9 82 0.61 202.0 53 0.66500 1325 12.5 106 0.36 115.0 1893 21.4 92 0.54 256.0 59 0.59600 1609 13.8 116 0.33 138.0 2299 23.7 102 0.49 310.0 65 0.54700 1903 15.2 125 0.31 160.0 2718 26.0 111 0.45 367.0 70 0.50800 2205 16.5 134 0.30 182.0 3150 28.2 119 0.42 426.0 74 0.47900 2516 17.7 142 0.29 205.0 3594 30.4 127 0.39 486.0 79 0.441000 2836 19.0 149 0.28 227.0 4051 32.5 135 0.37 549.0 83 0.421100 3164 20.2 157 0.27 250.0 4520 34.6 143 0.35 613.0 87 0.401200 3500 21.4 163 0.26 272.0 5000 36.7 151 0.33 678.0 91 0.381300 3842 22.6 170 0.26 294.0 5488 38.7 158 0.32 745.0 94 0.371400 4190 23.8 176 0.25 317.0 5986 40.7 165 0.30 814.0 98 0.35

Line Pressure

(bar)

Line Pressure

(kPa)

45° Rotor 30° Rotor AccuTest Reference Rotor

Qmax Sm3/h

Qmin Sm3/h

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

Press. Drop in mbar

Qmax Sm3/h

Qmin Sm3/h

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

Press. Drop in mbar

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

0.02 2 1000 55 18 55 8.2 1440 95.7 15 95.0 16.9 10 100

0.30 30 1291 63 20 49 10.5 1836 108.0 17 84.1 21.5 12 83

0.70 70 1703 73 23 44 13.7 2403 123.6 19 73.5 28.2 13 77

1.00 100 1977 78 25 40 16.2 2829 134.1 21 67.8 33.2 14 71

2.00 200 2972 96 31 32 24.3 4253 164.4 26 55.3 49.9 17 59

3.00 300 3973 111 36 28 32.4 5679 190.0 30 47.8 66.6 20 50

5.00 500 5986 137 44 23 48.5 8570 233.4 37 38.9 101.0 24 42

7.00 700 8020 159 51 20 64.7 11,473 270.0 42 33.7 135.0 22 36

8.00 800 9043 169 54 19 72.8 12,956 287.0 45 31.7 152.0 30 33

9.00 900 10,073 178 57 18 80.9 14,409 302.6 48 30.0 169.0 32 31

10.00 1000 11,107 187 59 17 89.0 15,902 317.9 50 28.6 187.0 33 30

12.00 1200 13,190 205 64 16 105.0 18,875 346.4 54 26.2 221.0 36 28

15.00 1500 16,346 229 72 14 129.0 23,258 384.5 60 23.6 273.0 40 25

20.00 2000 21,708 265 82 13 170.0 31,119 444.7 70 20.4 365.0 46 21

30.00 3000 32,823 330 100 11 251.0 46,813 545.5 86 16.7 549.0 55 18

35.00 3500 38,558 359 107 10 291.0 55,176 592.2 93 15.4 647.0 60 17

40.00 4000 44,455 388 114 10 332.0 63,881 637.2 100 14.3 749.0 63 16

50.00 5000 56,648 444 128 9 413.0 81,261 718.7 113 12.7 953.0 71 14

60.00 6000 69,363 497 140 8 494.0 99,691 796.0 125 11.4 1169.0 77 13

70.00 7000 82,640 548 151 8 575.0 118,499 867.8 137 10.5 1390.0 83 12

80.00 8000 96,374 599 161 7 655.0 138,322 937.6 148 9.7 1622.0 89 11

90.00 9000 110,554 648 171 7 736.0 159,214 1005.9 158 9.0 1867.0 95 11

100.00 10,000 125,364 698 180 7 817.0 180,742 1071.8 169 8.5 2119.0 100 10

Page 9: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

GT, GTS, GTX and AccuTest Turbine Gas Meters 09 Elster American Meter

8" GTS and AccuTest, Output Drive = 1000 Cubic Feet

Note: Capacity Table values established @ base pressure of 14.73 PSIA and base temperature of 60°F; 0.60 specific gravity gas. Supercompressibility included.

8" GTS and AccuTest, Output Drive = 10.0 Cubic Meters

Note: Capacity Table values established @ base pressure of 101.325 kPa and base temperature of 15°C. Supercompressibility included.

Line Pressure (PSIG)

45° Rotor 30° Rotor AccuTest Reference Rotor

Qmax MSCFH

Qmin MSCFH

Range Qmax/Qmin

Min. Actual Flow RateMACFH

Press. Drop in W.C.

Qmax MSCFH

Qmin MSCFH

Range Qmax/Qmin

Min. Actual Flow RateMACFH

Press. Drop in W.C.

Range Qmax/Qmin

Min. Actual Flow RateMACFH

0.25 60 3.0 20 3.00 1.6 88 5.9 15 5.87 3.4 10 6.005 79 3.4 23 2.61 2.1 116 6.7 17 5.11 4.5 12 5.0010 99 3.9 26 2.33 2.7 146 7.6 19 4.56 5.7 13 4.6215 120 4.2 28 2.13 3.2 176 8.3 21 4.16 6.8 14 4.2820 141 4.6 31 1.97 3.7 206 9.0 23 3.85 8.0 15 4.0025 161 4.9 33 1.84 4.3 236 9.6 25 3.60 9.1 17 3.5350 264 6.3 42 1.45 7.0 388 12.4 31 2.83 14.9 21 2.8675 368 7.5 49 1.23 9.7 540 14.6 37 2.41 20.7 25 2.40100 473 8.5 56 1.09 12.4 694 16.6 42 2.14 26.4 27 2.22125 579 9.4 62 0.99 15.2 850 18.4 46 1.95 32.2 31 1.96150 686 10.3 67 1.08 17.9 1006 20.1 50 2.11 38.0 33 1.82175 793 11.1 72 0.86 20.6 1164 21.6 54 1.68 43.7 36 1.67200 901 11.8 76 0.81 23.3 1322 23.1 57 1.59 49.5 38 1.58275 1232 13.9 89 0.71 31.4 1807 27.2 66 1.38 66.8 44 1.36300 1344 14.5 92 0.68 34.2 1971 28.4 69 1.33 72.6 46 1.30400 1800 17.0 106 0.60 45.0 2640 33.2 80 1.18 95.7 53 1.13500 2272 19.2 118 0.55 55.9 3332 37.6 89 1.08 119.0 59 1.02600 2759 21.4 129 0.51 66.7 4046 41.8 97 1.00 142.0 65 0.92700 3262 23.4 139 0.48 77.6 4784 45.8 104 0.95 165.0 70 0.86800 3780 25.4 149 0.46 88.5 5543 49.7 112 0.90 188.0 74 0.81900 4313 27.4 158 0.44 99.3 6326 53.5 118 0.87 211.0 79 0.761000 4862 29.3 166 0.43 110.0 7130 57.3 124 0.84 234.0 83 0.721100 5424 31.2 174 0.41 121.0 7955 61.0 130 0.81 257.0 87 0.691200 6000 33.0 182 0.40 132.0 8799 64.6 136 0.79 280.0 91 0.661300 6586 34.9 189 0.39 143.0 9659 68.2 142 0.77 303.0 94 0.641400 7183 36.7 196 0.38 154 10535 71.7 147 0.75 326.0 98 0.61

Line Pressure

(bar)

Line Pressure

(kPa)

45° Rotor 30° Rotor AccuTest Reference Rotor

Qmax Sm3/h

Qmin Sm3/h

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

Press. Drop in mbar

Qmax Sm3/h

Qmin Sm3/h

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

Press. Drop in mbar

Range Qmax/Qmin

Min. Actual Flow Rate

Am3/h

0.02 2 1700 85.0 20 84 4.0 2500 166.3 15 165.5 8.7 10 170

0.30 30 2195 97.0 23 76 5.1 3228 190.1 17 148.4 11.1 12 142

0.70 70 2895 112.0 26 67 6.7 4257 219.2 19 130.8 14.6 13 131

1.00 100 3360 120.0 28 61 7.9 4942 234.6 21 119.0 17.2 14 121

2.00 200 5053 147.0 34 50 11.8 7431 288.0 26 97.3 25.7 17 100

3.00 300 6755 170.0 40 43 15.8 9933 333.4 30 84.5 34.3 20 85

5.00 500 10,176 209.0 49 35 23.7 14,965 410.0 36 69.3 51.5 24 71

7.00 700 13,635 243.0 56 31 31.6 20,051 475.8 42 60.3 68.7 28 61

8.00 800 15,373 258.0 60 29 35.5 22,607 505.8 45 57.0 77.3 30 57

9.00 900 17,125 273.0 63 28 39.5 25,184 534.5 47 54.2 85.8 32 53

10.00 1000 18,882 287.0 66 26 43.4 27,768 561.9 49 51.8 94.4 33 52

12.00 1200 22,423 313.0 72 24 51.3 32,974 613.8 54 47.8 112.0 36 47

15.00 1500 27,788 350.0 79 22 63.2 40,865 685.6 60 43.4 137.0 40 43

20.00 2000 36,903 405.0 91 20 82.9 54,269 794.8 68 38.4 180.0 46 37

30.00 3000 55,799 504.0 111 16 122.0 82,057 989.0 83 32.3 266.0 55 31

35.00 3500 65,548 550.0 119 15 142.0 96,394 1078.2 89 30.3 309.0 60 28

40.00 4000 75,574 594.0 127 15 162.0 111,139 1164.8 95 28.8 352.0 63 27

50.00 5000 96,301 679.0 142 13 201.0 141,619 1330.8 106 26.4 438.0 71 24

60.00 6000 117,917 760.0 155 13 241.0 173,407 1490.0 116 24.8 524.0 77 22

70.00 7000 140,488 839.0 167 12 280.0 206,600 1645.4 126 23.5 610.0 83 20

80.00 8000 163,836 916.0 179 11 320.0 240,936 1796.5 134 22.5 695.0 89 19

90.00 9000 187,941 992.0 190 11 359.0 276,384 1944.3 142 21.6 781.0 95 18

100.00 10,000 213,119 1067.0 200 11 399.0 313,410 2092.8 150 21.0 867.0 100 17

Page 10: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

GT, GTS, GTX and AccuTest Turbine Gas Meters 10 Elster American Meter

12" GT, Output Drive = 1000 Cubic Feet, 45° Rotor

Note: Capacity Table values established @ base pressure of 14.73 PSIA and base temperature of 60°F; 0.60 specific gravity gas. Supercompressibility included.

12" GT, Output Drive = 10.0 Cubic Meters, 45° Rotor

Note: Capacity Table values established @ base pressure of 101.325 kPa and base temperature of 15°C. Supercompressibility included.

Line Pressure (PSIG)

Qmax MSCFH

Qmin MSCFH Range Qmax/Qmin Min. Actual Flow Rate

MACFH Press. Drop in W.C.

0.25 150 6.0 25 6.00 2.15 198 6.9 29 5.22 2.810 249 7.7 32 4.66 3.515 300 8.5 35 4.25 4.220 351 9.2 38 3.93 4.925 403 9.9 41 3.68 5.650 661 12.6 52 2.89 9.275 921 15.0 62 2.46 12.8100 1183 17.0 70 2.19 16.3125 1448 18.8 77 1.99 19.9150 1715 20.5 84 2.16 23.4175 1983 22.1 90 1.72 27.0200 2254 23.6 95 1.62 30.6275 3079 27.8 111 1.41 41.3300 3359 29.1 116 1.36 44.8400 4500 33.9 133 1.21 59.1500 5680 38.4 148 1.10 73.3600 6897 42.7 161 1.03 87.6700 8154 46.8 174 0.97 102.0800 9449 50.8 186 0.92 116.0900 10783 54.7 197 0.89 130.01000 12154 58.6 207 0.86 145.0

1100 13560 62.4 217 0.83 159.0

1200 14999 66.1 227 0.81 173.0

1300 16465 69.7 236 0.79 187.0

1400 17958 73.3 245 0.76 202.0

Line Pressure (bar)

Line Pressure (kPa)

Qmax Sm3/h

Qmin Sm3/h Range Qmax/Qmin Min. Actual Flow Rate

Am3/h Press. Drop in mbar

0.02 2 4289 171 25 170 5.20.30 30 5512 195 28 152 6.70.70 70 7269 225 32 134 8.71.00 100 8438 240 35 122 10.32.00 200 12,689 295 43 100 15.43.00 300 16,962 342 50 87 20.55.00 500 25,554 420 61 71 30.87.00 700 34,239 487 70 62 41.08.00 800 38,604 518 74 58 46.29.00 900 43,004 548 79 55 51.310.00 1000 47,416 576 82 53 56.412.00 1200 56,307 629 90 49 66.715.00 1500 69,782 702 99 44 82.120.00 2000 92,670 814 114 39 108.030.00 3000 140,121 1013 138 33 159.035.00 3500 164,603 1105 149 31 185.040.00 4000 189,780 1193 159 29 210.050.00 5000 241,829 1363 177 27 262.060.00 6000 296,110 1527 194 25 313.070.00 7000 352,790 1686 209 24 364.080.00 8000 411,422 1841 224 23 416.090.00 9000 471,954 1992 237 22 467.0100.00 10,000 535,179 2144 250 22 518.0

Page 11: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

A

B

A

BC

AA

B

BC

C

GT, GTS, GTX and AccuTest Turbine Gas Meters 11 Elster American Meter

GT, GTS, GTX and AccuTest Turbine Gas Meters - Other Technical Data

Ordering Information1 Size 2 Model3 Working pressure/Housing length 4 Standard or extended capacity (30° or 45° Rotor) 5 Drive Output (English or Metric) 6 Index (Pointer or Odometer)7 Options3" GT Turbine Meter 4", 6" & 8" GTS and GTX

and AccuTest Turbine Meter

4", 6" & 8" GTS and GTX E-Class Turbine Meter

12" GT Turbine Meter

Turbine Meter Dimensional TableMAOP Meter Dimensions Flange

O.D.Bolt

CircleFlange Bolts Hole

Size ANSI Shipping WeightPSIG Bar kPa A B B (E-Class) C No. Dia.

3" GT

275 9.18" 6.52" 10 lbs

1480 11.26" 6.52" 20 lbs

19 1900 233 mm 166 mm 4.5 kg

100 10,200 286 mm 166 mm 9.0 kg

4" GTS GTX

AccuTest

175 10.78" 14.00" 14.00" NA 9.00" 7.50" 8 5/8" 150 FF 32 lbs

740 10.78" 14.00" 15.50" .06" 10.00" 7.87" 8 3/4" 300 RF 150 lbs

1480 10.78" 14.00" 15.50" .25" 10.75" 8.50" 8 7/8" 600 RF 150 lbs

12 1200 274 mm 356 mm 356 mm NA 229 mm 190 mm 8 19 mm 150 FF 14.5 kg

50 5000 274 mm 356 mm 394 mm 1.5 mm 254 mm 200 mm 8 22 mm 300 RF 68 kg

100 10,200 274 mm 356 mm 394 mm 6.4 mm 273 mm 216 mm 8 25 mm 600 RF 68 kg

6" GTS GTX

AccuTest

175 11.85" 16.00" 16.00" NA 11.00" 9.50" 8 3/4" 150 FF 54 lbs

740 11.85" 18.00" 22.50" .06" 12.50" 10.62" 12 3/4" 300 RF 275 lbs

1480 12.34" 18.00" NA .25" 14.00" 11.50" 12 1" 600 RF 275 lbs

12 1200 301 mm 410 mm 410 mm NA 279 mm 241 mm 8 22 mm 150 FF 24.5 kg

50 5000 301 mm 460 mm 572 mm 1.5 mm 318 mm 270 mm 12 22 mm 300 RF 125 kg

100 10,200 313 mm 460 mm NA 6.4 mm 356 mm 292 mm 12 29 mm 600 RF 125 kg

8" GTS GTX

AccuTest

175 12.97" 21.00" 21.00" NA 13.50" 11.75" 8 3/4" 150 FF 90 lbs

740 12.97" 23.00" 27.25" .06" 15.00" 13.00" 12 7/8" 300 RF 450 lbs

1480 13.47" 23.00" NA .25" 16.50" 13.75" 12 1 1/8" 600 RF 450 lbs

12 1200 329 mm 535 mm 535 mm NA 343 mm 298 mm 8 22 mm 150 FF 47 kg

50 5000 329 mm 585 mm 693 mm 1.5 mm 381 mm 330 mm 12 25 mm 300 RF 205 kg

100 10,200 342 mm 585 mm NA 6.4 mm 419 mm 349 mm 12 32 mm 600 RF 205 kg

12" GT

175 20.00" 29.00" NA .06" 19.00" 17.00" 12 7/8" 150 FF 460 lbs

275 20.00" 29.00" NA .06" 19.00" 17.00" 12 7/8" 150 RF 490 lbs

740 20.57" 30.25" NA .06" 20.50" 17.75" 16 1 1/8" 300 RF 620 lbs

1480 21.00" 32.75" NA .25" 22.00" 19.50" 20 1 1/4" 600 RF 970 lbs

12 1200 508 mm 740 mm NA 1.5 mm 483 mm 432 mm 12 25 mm 150 FF 209 kg

19 1900 508 mm 740 mm NA 1.5 mm 483 mm 432 mm 12 25 mm 150 RF 222 kg

51 5000 522 mm 770 mm NA 1.5 mm 521 mm 451 mm 16 32 mm 300 RF 280 kg

102 10,200 533 mm 832 mm NA 6.4 mm 559 mm 495 mm 20 35 mm 600 RF 440 kg

Page 12: GT, GTS, GTX and AccuTest Turbine Gas · PDF fileGT, GTS, GTX and AccuTest Turbine Gas Meters 02 Elster American Meter. The turbine meters are designed to accurately measure natural

ISO 9001:2000

Certification No. 006697

About Elster GroupA world leader in advanced metering infrastructure, integrated metering, and utilization solutions to the gas, electricity and water industries. Elster’s metering and system solutions reflect over 170 years of knowledge and experience in measuring precious resources and energy.

Elster provides solutions and advanced technologies to help utilities more easily, efficiently and reliably obtain and use advanced metering intelligence to improve customer service, enhance operational efficiency, and increase revenues. Elster’s AMI solutions enable utilities to cost-effectively generate, deliver, manage, and conserve the life-essential resources of gas, electricity, and water.

Elster has a staff of over 7,500 serving customers globally in North America,Central America, South America, Europe,Asia, Africa and the Middle East.

1-800-955-4GASPhone: (215) 946-2200Fax: (215) 943-2984

[email protected]

1-800-955-4GASPhone: (215) 946-2200Fax: (215) 943-2984

[email protected]

1-800-955-4GASPhone: (215) 946-2200Fax: (215) 943-2984

[email protected]

nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
IMAC Systems, Inc 90 Main Street, PO Box 1605
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
Tullytown, PA. 19007
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
Distributed By:
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text
nkohart
Typewritten Text

Recommended