S EAS
T ST
E DAVIE ST
S PER
SON
ST
E CABARRUS ST
S BLO
ODWO
RTH
ST
Zoning:CAC:
Drainage Basin:Acreage:
Sq. Ft.:
DX-3-DE, HOD-GCentralWalnut Creek0.124,550
0 370185 Feet
Planner:Phone:
Applicant:Phone:
Michael Walters(919) 996-2636John Callahan(919) 828-4428
¯GUEST HOUSESR-21-2017 !
5/1/17 SR-21-17, Guest House 1
AA# 3604 Case File: SR-21-17, Guest House
Administrative Action Administrative Site Review
Case File / Name: SR-21-17, Guest House General Location: This site is located on the west side of S. Bloodworth Street, north of the
intersection of S. Bloodworth Street and East Cabarrus Street and is within the city limits.
CAC: Central Request: Development of a .12 acre tract zoned DX-3-DE and within an HOD-G Overlay
District. The project consists of the 2,658 square foot addition to an existing 1,842 square foot single family dwelling creating a 4500 square foot, 32’ 4” tall building to serve as an 8 room Inn for overnight lodging.
Cross- Reference: TR# 504689, RHDC COA 059-16-CA, RHDC COA 169-16-MW,
RHDC COA 013-17-MW Design Adjustment: One Design Adjustment has been approved by the Public Works Director for this
project, noted below.
1. Waiving Right of Way dedication as the property falls within the Christmas Street Plan.
2. Allowance of an alternative streetscape cross section. (street trees behind sidewalk, a 3.5’ grass strip, and a 5’ sidewalk)
3. Support of an encroachment into the Right of Way of a retaining wall and steps, all in order to support the established historic street edge
City of Raleigh Development Plans Review Center
One Exchange Plaza Raleigh, NC 27602
(919) 996-2626 www.raleighnc.gov
5/1/17 SR-21-17, Guest House 3
AA# 3604 Case File: SR-21-17, Guest House
SR-21-17, Preliminary Site Plan
5/1/17 SR-21-17, Guest House 5
AA# 3604 Case File: SR-21-17, Guest House
Code Conformance:
Code Section(s)
Zoning District: DX-3-DE, 3.1
Overlay District: HOD-G 5.1
Parking: Required = ½ parking space/room (8 rooms) = 4 spaces. As the first 10,000 square feet of parking is exempt in DX for a nonresidential use, zero parking is proposed. (7.1.3 A 1 d) Bicycle – Required Long Term spaces = 1 space/20 rooms (minimum 4). Proposed = 4 long term bike spaces.
7.1.2
Street Type(s): S. Bloodworth St.is classified as a Main Street Parallel Parking by the COR Street Plan. This street section consists of a 73' right-of-way with a 41' b-b street with street trees and 6' sidewalks on both sides.(UDO 8.4.5.D) Design adjustment waiving Right of Way dedication as the property falls within the Christmas Street Plan.
8.4
Streetscape: The Main Street streetscape is required based on the street designation. Two street trees are proposed along the frontage and within the Right of Way. Encroachment agreement for retaining walls and steps within Right of Way, in an effort to support the existing historic street edge Design adjustment for alternative streetscape cross section. (street trees behind sidewalk, a 3.5’ grass strip, and a 5’ sidewalk) Fee in lieu for 1’ of sidewalk width along the entire length of frontage
8.5
Setbacks/Frontage: As this site falls with the HOD-G overlay, setbacks and are determined as part of and in line with adjacent residences within the historic district. COA 059-16-CA COA 169-16-MW COA 013-17-MW
5.4.1 E
5/1/17 SR-21-17, Guest House 6
AA# 3604 Case File: SR-21-17, Guest House
Neighborhood Transitions:
NA 3.5
Transitional Protective Yards:
NA 7.2.4
Stormwater: Project claiming exemption afforded by UDO 9.2.2.A.1.b.ii as recently amended by TC-2-16. A ½ ac or less sized grandfathered lot approved prior to 5/1/01, that has not been altered to be greater than ½ ac., used for lawful use but subject to impervious limitation of subsection A. 4 of 65% impervious for its zoning. 61% Impervious proposed.. No further stormwater review required unless design changes occur that result in impervious exceeding 65%..
9.2
Tree Conservation: This site is less than two acres in size and therefore exempt from Article 9.1, Tree Conservation.
9.1
Variances, Design Adjustments,
Administrative Alternates:
One Design Adjustment has been approved by the Public Works Director for this project, noted below.
• Waiving Right of Way dedication as the property falls within the Christmas Street Plan.
• Allowance of an alternative streetscape cross section. (street trees behind sidewalk, a 3.5’ grass strip, and a 5’ sidewalk)
• Support of an encroachment into the Right of Way of a retaining wall and steps, all in order to support the established historic street edge.
There is an approved encroachment agreement for retaining walls and steps within Right of Way, in an effort to support the existing historic street edge
Other: Facility must contain and has proposed registration facilities, on-site management, cleaning services, and combined utilities. (6.4.6 D 1) 2 (96 gallon) refuse containers have been approved for use by the City of Raleigh Solid Waste Department.
5/1/17 SR-21-17, Guest House 8
AA# 3604 Case File: SR-21-17, Guest House
4-Year Completion Date: 4/28/2021 Within four years after issuance of the first building permit for the site plan, the construction of the entire site plan must be completed unless an applicant has been granted vested rights. Failure to complete construction within this specified time frame shall automatically void the approved site plan for which no building permits have been issued.
WHAT NEXT?:
• MEET ALL CONDITIONS OF APPROVAL. • COMPLETE INFRASTRUCTURE CONSTRUCTION DRAWINGS FOR ANY PUBLIC IMPROVEMENTS Streets, Utility lines to be owned and maintained by the City. • HAVE A REGISTERED SURVEYOR PREPARE FINAL PLATS FOR RECORDING. These also must be submitted to the City for authorization signature prior to recording with the Wake County Register of Deeds. • MEET THE REQUIREMENTS OF THE EXPIRATION THRESHOLDS AS NOTED ABOVE.
VICINITY MAP
(NOT TO SCALE)
JOHN A. EDWARDS & COMPANY
Consulting Engineers
NC License F-0289
333 Wade Ave., Raleigh, N.C. 27605
Phone: (919) 828-4428
Fax: (919) 828-4711
E-mail: [email protected]
INDEX
CE-1 EXISTING CONDITIONS
CE-2 SITE PLAN
CE-3 UTILITY PLAN
CE-4 GRADING PLAN
A200 FLOOR PLANS
A300 BUILDING ELEVATIONS
CIVIL ENGINEER:
OWNER/DEVELOPER:
GUESTHOUSE, LLC
P.O. BOX 28192
RALEIGH, NC 27610
SITE
Project
Client
Drawn By
Checked By
Date Issued
JOHN A. EDWARDS & COMPANY
Consulting Engineers
and Land Surveyors
NC License F-0289
333 Wade Ave., Raleigh, N.C. 27605
Phone: (919) 828-4428
Fax: (919) 828-4711
E-mail: [email protected]
www.jaeco.com
JAECO #
Client
GUEST HOUSE
420 S. BLOODWORTH ST
RALEIGH, NC 27601
GUEST HOUSE, LLC
215 HAYWOOD STREET
RALEIGH, NC 27601
Drawing
Title
Revisions
Number Description Date
Approvals
1 CITY OF RALEIGH COMMENTS 3/21/17
CE-1
10' 0 10' 20'
1"=10'
EXISTING
CONDITIONS
SO
UT
H
BLO
OD
WO
RT
H
ST
RE
ET
66' P
UB
LIC
R
IG
HT
O
F W
AY
N/F
CITY OF RALEIGH
PIN # 1703876040
DB 16685, PG 118
N/F
MARKETTE
WAGNER-HOLLAND
PIN # 1703865984
DB 8727, PG 2239
N/F
313 EAST CABARRUS STREET
LLC
PIN # 1703865919
DB 12856, PG 568
N/F
320 EAST DAVIE STREET LLC
PIN # 1703875250
DB 12856, PG 580
N/F
418 SOUTH BLOODWORTH
STREET LLC
PIN # 1703876028
DB 12856, PG 576
N/F
BEVERLY B. SMITH
PIN # 1703876121
DB 14602, PG 1161
N/F
GUESTHOUSE, LLC
PIN # 1703876033
DB 16543, PG 1235
5,069 SQFT
0.12 ACRES
4.29'
4.29'
11.22'
5.33'
5.31'
12.00'
7.00'
13.17'
27.33'
13.17'
EXISTING PLAN BASED ON SURVEY BY
SUMMIT COASTAL SURVEYING & MAPPING
ENTITLED "BOUNDARY & TOPOGRAPHIC
SURVEY - 420 BLOODWORTH STREET,
RALEIGH, WAKE COUNTY NC"
DATED: 7/21/2016
39.9' EX. B-B
5.0' EX. CONCRETE
SIDEWALK
62.2'
66' RIGHT-OF-WAY
4.29'
4.29'
11.22'
5.33'
5.31'
12.00'
7.00'
13.17'
27.33'
13.17'
Project
Seals
Client
Drawn By
Checked By
Date Issued
JOHN A. EDWARDS & COMPANY
Consulting Engineers
and Land Surveyors
NC License F-0289
333 Wade Ave., Raleigh, N.C. 27605
Phone: (919) 828-4428
Fax: (919) 828-4711
E-mail: [email protected]
www.jaeco.com
JAECO #
Client
GUEST HOUSE
420 S. BLOODWORTH ST
RALEIGH, NC 27601
GUEST HOUSE, LLC
215 HAYWOOD STREET
RALEIGH, NC 27601
Drawing
Title
Revisions
Number Description Date
Approvals
1 CITY OF RALEIGH COMMENTS 3/21/17
CE-3
10' 0 10' 20'
1"=10'
UTILITY
PLAN
SO
UT
H B
LO
OD
WO
RT
H S
TR
EE
T
66' P
UB
LIC
R
IG
HT
O
F W
AY
N/F
CITY OF RALEIGH
PIN # 1703876040
DB 16685, PG 118
N/F
MARKETTE
WAGNER-HOLLAND
PIN # 1703865984
DB 8727, PG 2239
N/F
313 EAST CABARRUS STREET
LLC
PIN # 1703865919
DB 12856, PG 568
N/F
418 SOUTH BLOODWORTH
STREET LLC
PIN # 1703876028
DB 12856, PG 576
6"x6"x2" TAPPING
SLEEVE & VALVE
BACKFLOW PREVENTER
IN BASEMENT
2" DOMESTIC
WATER METER
2" DOMESTIC
WATER LINE
2" GATE VALVE
PROPOSED
RETAINING
WALL
6" PVC SANITARY
SEWER SERVICE
(TYP)
SANITARY SEWER
CLEANOUT (TYP)
CURB STOP
HOSE LAY
PATH (307')
HOSE LAY
PATH (295')
HOSE LAY
PATH (TYP)
CABARRUS STREET
ACCESS GATE
ACCESS GATE
1 3/17/17 REVIEW COMMENTS
02/17/2017NNA
GuestHousePhase2.vwx2016_0001Permit Set
A300
Building Elevations
Structural:Lysaght & Associates120 Saint Marys St.Raleigh, NC 27605919-833-0495
Guest HousePhase 2420 S. Bloodworth St.Raleigh, NC 27601
311-200 W. Martin StreetRaleigh, NC 27601
919.821.2775919.821.0804 [email protected]
CONSULTANTS
SEALS
PROJECT
REVISIONS
PROJECT DATA
DATE:
PRINTING:PROJECT NO:FILENAME:CHECKED:DRAWN:
SHEET DATA
SHEET NO.
NO. DATE OF REVISION
AF E D C B
5
4
3
2
1
AF E D C B
ASR DRAWINGS02/17/2017
ASR DRAWINGS02/17/2017
ADDI
TION
RENO
VATI
ON
SIDE (NORTH) ELEVATIONScale: 1/8" = 1'-0"
4A300
SIDE (SOUTH) ELEVATIONScale: 1/8" = 1'-0"
2A300
ADDI
TION
RENO
VATI
ON
ADDI
TION
RENO
VATI
ON
ADDI
TION
RENO
VATI
ON
1
REAR (WEST) ELEVATIONScale: 1/8" = 1'-0"
3A300
F.F.E. 1ST FLOOR311'-2 1/2"
F.F.E. 2ND FLOOR322'-1/2"
T.O. RIDGE340'-1 1/2"
REAR ENTRY
REAR DECK
RAMPING ACCESS TO REAR ENTRY
SHED FOR LONG-TERM BICYCLE PARKING
RAMP ACCESS TO REAR ENTRY
NEW BRICK RETAINING WALL
REFUSE CONTAINER SCREENING
FRONT (EAST) ELEVATIONScale: 1/8" = 1'-0"
1A300
F.F.E. BASEMENT302'-0"
F.F.E. 1ST FLOOR311'-2 1/2"
F.F.E. BASEMENT ENTRY303'-6"
F.F.E. 2ND FLOOR322'-1/2"
T.O. RIDGE341'-1/2"
3'-6"
3'-6"
32'-4
"
NEW BRICK RETAINING WALL ALONG SIDEWALK
NEW CONCRETE STAIRS
RAMPING ACCESS TO MAIN REAR ENTRYNEW BRICK RETAINING WALL SLOPING WITH ACCESS PATH
3'-6"
BASEMENT ENTRYREAR DECKSHED FOR LONG-TERM BICYCLE PARKING
NEW BRICK RETAINING WALL
12'-5
"
33'-4"
RELOCATED HISTORIC HOUSE MEETS FACADE ARTICULATION STANDARD. - FRONT WALL LENGTH WITHOUT OFFSET = 33’-4” (40’ MAX)
RELOCATED HISTORIC HOUSE MEETS TRANSPARENCY STANDARDS.- GROUND STORY = 22% (20% MIN.)- UPPER STORY = 16% (15% MIN.)(SEE TRANSPARENCY CALCULATIONS BELOW)
5'-6" 6'-8" 6'-8" 5'-6"
RELOCATED HISTORIC HOUSE MEETS BLANK WALL STANDARDS.- BLANK WALL AREA: 5’-6” + 6’-8” + 6’-8” + 5’-6” = 24’-4” (35’ MAX.)
UPPER STORY WINDOW 1 = 16 SFWINDOW 2 = 16 SFWINDOW 3 = 16 SF
= 48 SFWALL AREA = 302 SFTRANSPARENCY = 16%
16 SF
TRANSPARENCY CALCULATIONS
27 SF 27 SF
GROUND STORY WINDOW 1 = 27 SFWINDOW 2 = 27 SFDOOR = 27 SF
= 81 SFWALL AREA = 361 SFTRANSPARENCY = 22%
REFUSE CONTAINER SCREENING
6'-0"