The Quality Insulation Products for Many Diverse Application TEL: 00971 6 5257776, FAX: 00971 6 5257774 P.O.BOX: 22069, SHARJAH – UNITED ARAB EMIRATES Email 1: [email protected] Email 2: [email protected] Email 3: [email protected] Gulf Cool Therm Polyisocyanurate (PIR) Insulation CHILLED WATER PIPE AND DUCT INSULATION CONTINUOUS PIR FOAM BLOCK PRODUCTION CRYOGENIC INSULATION COLD INSULATION FOR OIL, GAS AND REFINERY INDUSTRIES SLAB / BOARD INSULATION EQUIPMENT / TANK / VESSEL INSULATION HIGH DENSITY THERAMAL PIPE SUPPORT INSERTS HIGH DENSITY THERMAL DUCT SUPPORT INSERTS HIGH DENSITY SUPPORT SPACER www.gulfcooltherm.com
Transcript
Page 1: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

The Quality Insulation

Products for Many Diverse

Application

TEL: 00971 6 5257776, FAX: 00971 6 5257774

P.O.BOX: 22069, SHARJAH – UNITED ARAB EMIRATES

Email 1: [email protected]

Email 2: [email protected]

Email 3: [email protected]

Gulf Cool Therm

Polyisocyanurate (PIR) Insulation

CHILLED WATER PIPE AND DUCT INSULATION

CONTINUOUS PIR FOAM BLOCK PRODUCTION

CRYOGENIC INSULATION

COLD INSULATION FOR OIL, GAS AND REFINERY INDUSTRIES

SLAB / BOARD INSULATION

EQUIPMENT / TANK / VESSEL INSULATION

HIGH DENSITY THERAMAL PIPE SUPPORT INSERTS

HIGH DENSITY THERMAL DUCT SUPPORT INSERTS

HIGH DENSITY SUPPORT SPACER

www.gulfcooltherm.com

Page 2: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

www.gulfcooltherm.com

Page 3: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

www.gulfcooltherm.com1

ABOUT US

We are pleased to introduce ourselves as a factory established in 1993, Sharjah – United Arab Emirates.

Gulf Cool Therm Factory LLC is an ISO 9001:2008 Certi"ed Company with Quality System certi"ed by

UKAS of United Kingdom.

Gulf Cool Therm Factory LLC, is a leading manufacturers and suppliers of high quality:

Thermal Insulation Materials

Pre-insulated Pipes and Fittings for District Cooling Application

Polyisocyanurate Pipe, Duct, Slab and Vessel/Equipment Insulation

Polyurethane Pipe, Slab and Vessel/Equipment Insulation

Class ‘O’ CFC & HCFC Free Phenolic Foam Pipe, Duct, Wall and Roof Insulation

Continuous PIR/PUR Foam Block Production

Cold Insulation Materials for LNG, Oil and Gas Industries

Foam Glass Insulation

Phenolic Foam / Polyisocyanurate Pre-insulated Air Duct Panels

Roof and Wall Insulation

Polyurethane Spray Applied Foam

High Density Thermal Support Inserts for piping and Ducting

Heat Exchanger Insulated Box and Tray

Field Joint Insulation and Application

With many CNC Foam cutting machineries and production process units in the "eld with quality mate-

rial available, highly quali"ed technical and commercial sta#. We are con"dent that our product will

comply with all international standard and de"nitely will meet your requirements.

In order to facilitate our client with best service and respect to quality, prompt delivery, respective

elements of production and marketing were provided and enhanced under a tight quality control.

Page 4: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

2

Chilled Water Pipe, Duct and Slab Insulation

Materials

Product Description

Gulf Cool Therm Polyisocyanurate CFC free rigid closed cell foam manufac-

tured in similar way to standard Polyurethane, Gulf Cool Therm Polyisocy-

anurate has all the characteristics and advantages of rigid Polyurethane

foam but o"ers greatly increased resistance to burning and spread of #ame

and is able to withstand temperatures up to 140 oC. When subjected to $re

the outer surface of the foam forms a strong carbonaceous layer, which

retards further #ame spread and penetration. For ease of identi$cation.

Gulf Cool Therm Polyisocyanurate CFC free rigid closed cell foam with a low

Thermal Conductivity of 0.023 W/m oC at 10 oC, gives excellent thermal

properties and $re properties when tested in accordance with ASTM E 84,

and BS 476 Part 7, Class 1 rating.

Gulf Cool Therm Polyisocyanurate rigid insulation is 95% closed cell and

provides a long end satisfactory service life.

Gulf Cool Therm PHENOLIC FOAM PIPE AND DUCT INSULATIONGulf Cool Therm PHENOLIC FOAM PIPE, DUCT & SLAB INSULATION

Gulf Cool Therm Polyisocyanurate CFC free rigid closed cell insulation

materials display excellent insulation characteristics. They have extremely

low thermal conductivity values and can achieve optimal energy savings.

The excellent mechanical strength values and exceptional durability of rigid

Gulf Cool Therm Polyisocyanurate ful$l all the requirements made of

insulation materials used in the building industry.

Applications

Gulf Cool Therm Polyisocyanurate CFC free rigid closed cell insulation has

many diverse applications in Air-Conditioning Systems, Oil, Petrochemical,

Process Plant and General Insulation Industries. It can be used for Pipe,

Duct, Tank, Vessel and Equipment Insulation.

Densities

35Kg/m3 to 65Kg/m3 for Pipe Sections, Duct Insulation and Slabs.

80Kg/m3 to 200Kg/m3 for Thermal Support Inserts

Other Densities are available upon request

Gulf Cool Therm PHENOLIC FOAM PIPE AND DUCT INSULATIONGulf Cool Therm PHENOLIC FOAM PIPE, DUCT & SLAB INSULATIONGulf Cool Therm POLYISOCYANURATE (PIR) INSULATION

2

provides a long end satisfactory service life.low thermal conductivity values and can achieve optimal energy savings.

The excellent mechanical strength values and exceptional durability of rigid

Gulf Cool Therm Polyisocyanurate ful$l all the requirements made of

insulation materials used in the building industry.

Applications

Gulf Cool Therm Polyisocyanurate CFC free rigid closed cell insulation has

many diverse applications in Air-Conditioning Systems, Oil, Petrochemical,

Process Plant and General Insulation Industries. It can be used for Pipe,

Duct, Tank, Vessel and Equipment Insulation.

Densities

35Kg/m3 to 65Kg/m3 for Pipe Sections, Duct Insulation and Slabs.

80Kg/m3 to 200Kg/m3 for Thermal Support Inserts

Other Densities are available upon request

www.gulfcooltherm.com

Page 5: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

3

AVAILABILITY

Pipe Insulation, Duct Insulation, Slab Insulation

Pipe Support Inserts

Duct Support Inserts

PIPE FITTINGS Including Elbows, Tees, Valve, Covers... etc...

PIR Foam Blocks/Slabs for Design Mould and Boat/Ship partition/support

work.

Gulf Cool Therm Polyisocyanurate insulation is available as sectional pipe

covering, complete with a vapour barrier jacket, as well as sections for

"ttings, board, segments for equipment and large vessels.

Factory fabrication Standards: ASTC C 450 and ASTM C 585

FINISHING

PIPE SECTION with reinforced Aluminium Class ‘1’ foil faced.

PIPE SECTION with reinforced aluminium Class ‘O’ foil faced.

PIPE SECTION with Aluglass foil faced (Aluminized glass Cloth). Gulf Cool

Therm Polyisocyanurate Aluglass Finished Insulation is easy to "t and

installation cost can save because of applying canvas cloth and vapour

barrier will not be required.

PIPE Support Inserts or DUCT SSupport Inserts faced with reinforced

Aluminium foil, Aluglass foil or Un-faced.

Gulf Cool Therm PHENOLIC FOAM PIPE AND DUCT INSULATIONGulf Cool Therm PHENOLIC FOAM PIPE, DUCT & SLAB INSULATIONGulf Cool Therm POLYISOCYANURATE (PIR) INSULATION

ADVANTAGES

High Temperature Service – Gulf Cool Therm Polyisocyanurate insulation

does not soften or lose its strength at elevated temperatures within the

recommended use limits.

Low Thermal Conductivity – Procuring at the factory provides consistent

makes physical properties.

Easy Installation – Its light weight and ease of adherence to a variety of

surfaces makes it east to apply.

Gulf Cool Therm Polyisocyanurate is having high thermal properties i.e.

Low thermal conductivity, High Compressive strength, durability and

dimensional stability.

Gulf Cool Therm Polyisocyanurate is 95% closed cell and keep insulation

dry and secured until the life time of the construction.

Gulf Cool Therm PHENOLIC FOAM PIPE AND DUCT INSULATIONGulf Cool Therm PHENOLIC FOAM PIPE, DUCT & SLAB INSULATIONGulf Cool Therm POLYISOCYANURATE (PIR) INSULATION

3

Therm Polyisocyanurate Aluglass Finished Insulation is easy to "t and

installation cost can save because of applying canvas cloth and vapour

barrier will not be required.

PIPE Support Inserts or DUCT SSupport Inserts faced with reinforced

Aluminium foil, Aluglass foil or Un-faced.

Low Thermal Conductivity – Procuring at the factory provides consistent ty

makes physical properties.

Easy Installation – Its light weight and ease of adherence to a variety of

surfaces makes it east to apply.

Gulf Cool Therm Polyisocyanurate is having high thermal properties i.e.

Low thermal conductivity, High Compressive strength, durability and

dimensional stability.

Gulf Cool Therm Polyisocyanurate is 95% closed cell and keep insulation

dry and secured until the life time of the construction.

www.gulfcooltherm.com

Page 6: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

Gulf Cool Therm PHENOLIC FOAM PIPE AND DUCT INSULATIONGulf Cool Therm PHENOLIC FOAM PIPE, DUCT & SLAB INSULATION

A λ factor, R-value per 100mm, and thicknesses for an R-value of 1 (m2 0K /W) for

common insulation materials are shown below.

Comparative Thickness (mm) of commonly Speci#ed Insulation Materials

Required for Speci#c Metrics Values of Thermal Resistance (R-value)1

Comparative Thickness for same degree of Insulation (Dry

Conditions)

Thickness of Gulf Cool Therm Polyisocyanurate (PIR) for Calculated

Metric Values of Thermal Resistance (R-value)

Gulf Cool Therm POLYISOCYANURATE (PIR) INSULATION

www.gulfcooltherm.com

1 Metric R= 1 Corresponds to British Thermal Unit R-Factor 1

2 λ = W/m2 K Corresponds to British Theraml Unit K-Factory

m2 KW

(Btu) (in)(ft2) (oF) (Hr)

(Btu) (in)(ft2) (oF) (Hr)

4

Page 7: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

5

Gulf Cool Therm PHENOLIC FOAM PIPE AND DUCT INSULATIONGulf Cool Therm PHENOLIC FOAM PIPE, DUCT & SLAB INSULATION

Increase in thermal conductivity at various temperatures and prolonged storage time

For low temperature application Gulf Cool Therm Polyiscyanurate (PIR) must be covered with a vapour barrier to avoid condensation or icing.

Gulf Cool Therm POLYISOCYANURATE (PIR) INSULATION

5 www.gulfcooltherm.com

+

The graphs shown the Theramal Conductivity movement

against mean temperature.

SERVICE TEMPERATURES

Gulf Cool Therm Polyiscyanurate (PIR) can be used from

-160 OC up to +140 oC. Temperatures below 0 OC and above

120 OC require special methods of installation. In such

cases do not hesitate to contact us.

Page 8: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

6

Gulf Cool Therm PHENOLIC FOAM PIPE AND DUCT INSULATIONGulf Cool Therm PHENOLIC FOAM PIPE, DUCT & SLAB INSULATION

WORKABILITY

Gulf Cool Therm Polyiscyanurate (PIR) can be easily cut

with saw blades or knives. It is resistant to all kinds of

adhesive, bituminous emulsions and hot bitumen (180

OC to 220 OC). We will, however, assist you to "nd the

proper adhesives for your particular application.

Gulf Cool Therm POLYISOCYANURATE (PIR) INSULATION

6 www.gulfcooltherm.com

The

gra

ph

sh

ow

s th

e Th

erm

al C

on

ud

uct

ivit

y o

f Gu

lf C

oo

l T

he

rm P

oly

iso

cya

nu

rate

(PIR

)

Foam

at

di#

eren

t d

ensi

ties

.

+

Page 9: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

7

Gu

lf C

oo

l T

he

rm P

HE

NO

LIC

FO

AM

PIP

E A

ND

DU

CT

INS

UL

AT

ION

Gu

lf C

oo

l T

he

rm P

HE

NO

LIC

FO

AM

PIP

E, D

UC

T &

SL

AB

INS

UL

AT

ION

Gu

lf C

oo

l T

he

rm P

OLY

ISO

CY

AN

UR

AT

E (

PIR

) IN

SU

LA

TIO

N

Pro

pe

rtie

s T

est

Me

tho

d

Va

lue

V

alu

e

Va

lue

V

alu

e

Va

lue

V

alu

e

Va

lue

V

alu

e

Va

lue

V

alu

e

Va

lue

No

min

al D

en

sity

: Kg

/m3

(lb

/ft3

) A

ST

M D

-16

22

P

IR 3

5

(2.1

8)

PIR

50

(3.1

2)

PIR

65

(4.0

5)

TS

80

(4.9

9)

TS

10

0

(6.2

4)

TS

12

0

(7.4

9)

TS

16

0

(9.9

8)

TS

18

0

(11

.23

)

TS

20

0

(12

.48

)

TS

25

0

(15

.60

)

TS

36

0

(22

.47

)

Th

erm

al C

on

du

ctiv

ity

@ 1

0O

C (

50

oF

) a

ge

d

W /

m*K

(B

tu-i

n/h

*ft2

oF

) A

ST

M C

51

8/9

1

0.0

23

(0.1

59

)

0.0

23

(0.1

59

)

0.0

24

(0.1

66

)

0.0

27

(0.1

87

)

0.0

30

(0.2

07

)

0.0

32

(0.2

21

)

0.0

36

(0.2

48

6)

0.0

36

(0.2

48

6)

0.0

38

(0.2

62

)

0.0

38

(0.2

62

)

0.0

40

(0.2

76

)

Av

era

ge

Co

mp

ress

ive

Str

en

gth

@ 1

0%

Re

lati

ve D

efo

rma

tio

n: k

Pa

(lb

/in

+

10

%2)

AS

TM

D-1

62

1

BS

EN

82

6:1

99

6

24

5

(35

.53

)

36

5

(52

.93

)

75

0

(10

8.7

7)

11

20

(16

2.4

4)

13

50

(19

5.7

9)

14

25

(20

6.6

7)

>1

79

0

(25

9.6

0)

>2

00

0

(>2

90

.06

)

>2

40

0

(>3

48

.09

)

>4

00

0

(>5

80

.13

)

>7

00

0

(>1

01

5.2

3)

Co

mp

ress

ive

Mo

du

lus:

kP

a (

lb/i

n2)

AS

TM

F-1

83

9-0

1

13

02

0

(18

88

.39

)

18

60

0

(26

97

.70

)

24

20

0

(35

09

.91

)

29

88

0

(43

33

.72

)

37

36

0

(43

33

.72

)

44

83

0

(65

02

.04

)

59

60

0

(86

44

.24

)

66

30

0

(96

16

.00

)

72

25

0

(10

47

8.9

8)

90

15

0

(13

07

5.1

5)

12

83

50

(18

61

5.5

9)

Te

nsi

le S

tre

ng

th: k

Pa

(lb

/in

2)

AS

TM

D-1

62

3

22

0

(31

.9)

38

5

(55

.83

)

73

0

(10

5.8

7)

10

80

(15

6.6

4)

13

40

(19

5.6

5)

16

10

(23

3.5

1)

21

40

(31

0.3

6)

24

00

(34

8.0

7)

26

50

(38

4.3

3)

>3

31

0

(>4

80

.05

)

>4

30

0

(>6

23

.63

)

Sh

ea

r S

tre

ng

th: k

Pa

(lb

/in

2)

AS

TM

F-1

83

9-0

1

22

5

(32

.63

)

39

0

(56

.56

)

61

0

(88

.47

)

85

0

(12

3.2

8)

10

70

(15

5.1

9)

12

80

(18

5.6

4)

15

25

(22

1.1

7)

17

30

(25

0.9

)

19

50

(28

2.8

1)

>2

44

5

(>3

54

.6)

>3

21

0

(>4

65

.55

)

Sh

ea

r M

od

ulu

s: k

Pa

(lb

/in

2)

AS

TM

F-1

83

9-0

1

36

20

(52

5.0

3)

52

10

(75

5.6

4)

67

70

(98

1.9

)

10

91

0

(15

82

.36

)

13

64

0

(19

78

.31

)

16

36

0

(23

72

.81

)

17

02

0

(24

68

.54

)

>1

87

30

(>2

71

6.5

5)

20

80

0

(30

16

.78

)

>2

59

45

(>3

76

3.0

0)

>3

73

50

(>5

41

7.1

6)

Clo

sed

Ce

ll C

on

ten

t (A

pp

are

nt

vo

l, %

) A

ST

M D

-28

56

9

5

95

9

5

96

9

8

98

9

8

98

9

8

98

9

8

Av

g. W

ate

r V

ap

or

Tra

nsm

issi

on

(g

rain

s/h

*ft2

) A

ST

M E

96

-00

1

.6

1.5

1

.25

1.2

1

0

.8

0.6

0

.6

0.5

0

.4

0.3

Av

g. 6

A

ST

M D

-28

42

2

.25

2

1

.5

1.3

0

.8

0.8

0

.3

0.3

0

.3

0.2

5

0.2

Dim

en

sio

nal

Sta

bil

ity

(%

Lin

ear

Ch

an

ge

)

24

ho

urs

@ -

20

OC

24

ho

urs

@ +

11

0 O

C

24

ho

urs

@ +

70

OC

10

0%

RH

AS

TM

D-2

12

6

Ne

gli

gib

le

1.5

2

Ne

gli

gib

le

1.5

2

Ne

gli

gib

le

1

1.5

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Up

pe

r T

em

pe

ratu

re L

imit

OC

(OF

)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

Lin

ea

r C

oe

"ci

en

t o

f E

xpa

nsi

on

m/m

∙K

AS

TM

D-6

96

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

Fir

e r

esi

sta

nce

(sm

all s

cale

te

st)

BS

47

6 P

art

5

Cla

ss P

C

lass

P

Cla

ss P

C

lass

P

Cla

ss P

C

lass

P

Cla

ss P

C

lass

P

Cla

ss P

C

lass

P

Cla

ss P

Su

rfa

ce S

pre

ad

of

Fla

me

B

S4

76

Pa

rt 7

C

lass

1

Cla

ss 1

C

lass

1

Cla

ss 1

C

lass

1

Cla

ss 1

C

lass

1

Cla

ss 1

C

lass

1

Cla

ss 1

C

lass

1

Fla

me

Sp

rea

d In

de

x A

ST

M E

84

25

25

25

2

5

25

2

5

25

2

5

25

2

5

25

Sm

oke

De

velo

pe

d In

de

x A

ST

M E

84

4

5

45

4

5

45

4

5

45

4

5

45

4

5

45

4

5

Av

era

ge

Tim

e o

f B

urn

ing

(m

m)

AS

TM

D-6

35

:91

<

5

<5

<

5

5

5

5

5

5

5

5

5

Av

era

ge

Ext

en

d o

f B

urn

ing

(m

m)

AS

TM

D-6

35

:91

<

5

<5

<

5

5

5

5

5

5

5

5

5

Fla

mm

ab

ilit

y-w

eig

ht

reta

ine

d

AS

TM

D-3

01

4-7

4

90

%

90

%

90

%

90

%

90

%

90

%

90

%

90

%

90

%

90

%

90

%

Lig

ht

Ob

scu

rati

on

A

ST

M D

-28

43

-70

3

0%

3

0%

3

0%

3

0%

3

0%

3

0%

3

0%

3

0%

3

0%

3

0%

3

0%

Ob

scu

rati

on

B

S 5

11

1 P

art

1

35

%

35

%

35

%

35

%

35

%

35

%

35

%

35

%

35

%

35

%

35

%

Th

is le

a&e

t ca

nce

ls a

nd

su

pe

rse

de

s al

l pre

vio

us

ed

itio

ns.

We

re

serv

e t

he

tig

ht

to a

me

nd

sp

eci

'ca

tio

n w

ith

ou

t p

rio

r n

oti

ce. W

hils

t th

e in

form

ati

on

co

nta

ine

d in

th

e le

a&

et

is t

rue

an

d a

ccu

rate

to

th

e b

est

of

ou

r kn

ow

led

ge

an

d b

elie

f, a

ll

lia

bili

ty f

or

err

ors

an

d o

mis

sio

ns,

dam

ag

e o

r lo

ss r

esu

ltin

g h

ere

fro

m is

he

reb

y e

xclu

de

d. R

eco

mm

en

da

tio

ns

for

use

s sh

ou

ld b

e v

eri

'e

d a

s to

su

itab

ilit

y a

nd

co

mp

lia

nce

wit

h a

c tu

al

req

uir

em

en

ts, s

pe

ci'

cati

on

an

d a

ny

ap

pli

cab

le l

aw

s

an

d r

eg

ula

tio

ns.

AS

TM

D-1

62

3

(31

.9)

(55

.83

) (1

05

.87

) (1

56

.64

) (1

95

.65

) (2

33

.51

) (3

10

.36

) (3

48

.07

) (3

84

.33

) (>

48

0.0

5)

(>6

23

.63

)

AS

TM

F-1

83

9-0

1

22

5

(32

.63

)

39

0

(56

.56

)

61

0

(88

.47

)

85

0

(12

3.2

8)

10

70

(15

5.1

9)

12

80

(18

5.6

4)

15

25

(22

1.1

7)

17

30

(25

0.9

)

19

50

(28

2.8

1)

>2

44

5

(>3

54

.6)

>3

21

0

(>4

65

.55

)

AS

TM

F-1

83

9-0

1

36

20

(52

5.0

3)

52

10

(75

5.6

4)

67

70

(98

1.9

)

10

91

0

(15

82

.36

)

13

64

0

(19

78

.31

)

16

36

0

(23

72

.81

)

17

02

0

(24

68

.54

)

>1

87

30

(>2

71

6.5

5)

20

80

0

(30

16

.78

)

>2

59

45

(>3

76

3.0

0)

>3

73

50

(>5

41

7.1

6)

AS

TM

D-2

85

6

95

9

5

95

9

6

98

9

8

98

9

8

98

9

8

98

) A

ST

M E

96

-00

1

.6

1.5

1

.25

1.2

1

0

.8

0.6

0

.6

0.5

0

.4

0.3

AS

TM

D-2

84

2

2.2

5

2

1.5

1

.3

0.8

0

.8

0.3

0

.3

0.3

0

.25

0

.2

AS

TM

D-2

12

6

Ne

gli

gib

le

1.5

2

Ne

gli

gib

le

1.5

2

Ne

gli

gib

le

1

1.5

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

Ne

gli

gib

le

<1

<1

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

14

0 (

28

4)

AS

TM

D-6

96

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

4

0-7

0x1

0-6

BS

47

6 P

art

5

Cla

ss P

C

lass

P

Cla

ss P

C

lass

P

Cla

ss P

C

lass

P

Cla

ss P

C

lass

P

Cla

ss P

C

lass

P

Cla

ss P

BS

47

6 P

art

7

Cla

ss 1

C

lass

1

Cla

ss 1

C

lass

1

Cla

ss 1

C

lass

1

Cla

ss 1

C

lass

1

Cla

ss 1

C

lass

1

Cla

ss 1

AS

TM

E 8

4

≤2

5

≤2

5

≤2

5

25

2

5

25

2

5

25

2

5

25

2

5

AS

TM

E 8

4

45

4

5

45

4

5

45

4

5

45

4

5

45

4

5

45

AS

TM

D-6

35

:91

<

5

<5

<

5

5

5

5

5

5

5

5

5

AS

TM

D-6

35

:91

<

5

<5

<

5

5

5

5

5

5

5

5

5

AS

TM

D-3

01

4-7

4

90

%

90

%

90

%

90

%

90

%

90

%

90

%

90

%

90

%

90

%

90

%

AS

TM

D-2

84

3-7

0

30

%

30

%

30

%

30

%

30

%

30

%

30

%

30

%

30

%

30

%

30

%

BS

51

11

Pa

rt 1

3

5%

3

5%

3

5%

3

5%

3

5%

3

5%

3

5%

3

5%

3

5%

3

5%

3

5%

tio

ns.

We

re

serv

e t

he

tig

ht

to a

me

nd

sp

eci

'ca

tio

n w

ith

ou

t p

rio

r n

oti

ce. W

hils

t th

e in

form

ati

on

co

nta

ine

d in

th

e le

a&

et

is t

rue

an

d a

ccu

rate

to

th

e b

est

of

ou

r kn

ow

led

ge

an

d b

elie

f, a

ll

resu

ltin

g h

ere

fro

m is

he

reb

y e

xclu

de

d. R

eco

mm

en

da

tio

ns

for

use

s sh

ou

ld b

e v

eri

'e

d a

s to

su

itab

ilit

y a

nd

co

mp

lia

nce

wit

h a

c tu

al

req

uir

em

en

ts, s

pe

ci'

cati

on

an

d a

ny

ap

pli

cab

le l

aw

s

ww

w.g

ulf

coo

lth

erm

.co

m

TE

CH

NIC

AL

DA

TA

SH

EE

T

Page 10: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

www.gulfcooltherm.com

Page 11: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

www.gulfcooltherm.com

Page 12: Gulf Cool Thermgulfcooltherm.com/pds-files/PIR Catalogue.pdf · 2 Chilled Water Pipe, Duct and Slab Insulation Materials Product Description Gulf Cool Therm Polyisocyanurate CFC free

The Quality Insulation

Products for Many Diverse

Application

Easy to Fit - Energy Saving

www.gulfcooltherm.com