GVT 154 20°-65° Installation instructions for roof window P. 2-6 Profiled roofing material P. 7-11 Flat roofing material P. 12-15 Plain tiles Do not expose the window to direct heat sources.
Transcript
Page 1: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

GVT 154

20°-65°

Installation instructions for roof window

P. 2-6 Profiled roofing material

P. 7-11 Flat roofing material P. 12-15 Plain tiles

Do not expose the window to direct heat sources.

Page 2: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

1a

2

Illustration shows roofing con-struction without underfelt.Roofing construction with under-felt, see page 16. Fix windowdirectly onto roof battens.Ensure that the bearing (lower)batten is continuous over theadjacent rafters. Fix the bearingbatten with two nails in eachrafter. If necessary a supportingbatten should be fitted at thetop.

1a

Rafter construction with profiled roofing material, max. 60 mm

20°-65°

620 mm

min

. 108

0 m

mm

ax. 1

180

mm

60-1

50 m

m

min. 1

5 mm

30-60 mm

Page 3: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

1b

3

Fix window directly onto battens countersunk in concrete.

1b

Concrete slab with profiled roofing material, max. 60 mm

650 mm

60-150 mm

30-60 mm 30-60 mm

1150

mm

20°-65°

Page 4: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

4

2

1

Remove transportation battens.

Sash may be removed to facili-tate installation. Release restrictorstay from frame (1). Removescrews in the middle of thehinges and loosen screws at thebottom (2).

1

2

2

Page 5: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

5

1 2

Fix bottom brackets with twoscrews (1). Push top adjustablebrackets up towards batten andfix with screws (2).

You must not cut the course oftile below the window. If necessary, profiles should bechamfered as shown.

2 2

1 1

Page 6: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

6

1

2

3

1

1

2

2

Dress apron over roofing material(1), bending it at the sides (2) toprevent water from penetratingthe corners. Place roofing mate-rial, maintaining a distance of30-60 mm to side frame and adistance of 60-150 mm to topframe. Slit foam gasket justabove each tile to allow gasketto seal against underside of tiles(3).

Replace sash and fasten screws(1). Fix restrictor stay (2). If sashis to be positioned on the oppo-site side, see instructions in bag (A).

A

30-60 mm

60-1

50 m

m

1

Page 7: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

1 2

2

3

7

Rafter construction with flatroofing material

Illustration shows roofing con-struction without underfelt.Roofing construction with under-felt, see page 16. Fix windowdirectly onto roof battens.Ensure that the bearing (lower)batten is continuous over theadjacent rafters. Fix the bearingbatten with two nails in eachrafter. Fix a supporting battenunder the bearing batten (1)with minimum 4 nails. Remove 7 mm rebate from battens asshown (2). If necessary, a sup-porting batten may be fitted atthe top (3).

1a

650 mm

100 mm

580 mm

90 mm

60-1

00 m

m

30 mm

min. 1

5 mm

7 mm

min

. 108

0 m

mm

ax. 1

180

mm

20°-65°

1a

Page 8: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

65 mm

65 mm

55 mm

3 mm4.0 x 40

11

1b

8

Boarded roof with flat roofing material

In boarded roofs with up to 900 mm between rafters suppor-ting battens must be positioned7 mm below surface of boards.Fix supporting battens (1) withbrackets and annular ringshanks with shown dimensions.Fix each bracket to rafters withtwo annular rink shanks.

1b

820 mm

60-1

00 m

m

min. 1

5 mm

30 mm

7 mm

min. 650 mmm

in. 1

080

mm

max

. 118

0 m

m

1310

mm

20°-65°

Page 9: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

9

2

1

2

Remove transportation battens.

Remove foam and tile support.

Sash may be removed to facilita-te installation. Release restrictorstay from frame (1). Removescrews in the middle of thehinges and loosen screws at thebottom (2).

2

2

1

Page 10: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

10-20 mm

10

1 1 1

2 2

2

Fix bottom brackets with twoscrews (1). Push top adjustablebrackets up towards batten andfix with screws (2).

Cut two pieces of aluminium orzinc and fit around bottom cor-ners.

Adjust and position roofingmaterial below window.

Page 11: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

30 mm

11

30 mm

60-1

00 m

m

Roll out apron. Place roofingmaterial, maintaining a distanceof 30 mm to side frame and 60-100 mm to top frame.

Replace sash and fasten screws(1). Fix restrictor stay (2). If sashis to be positioned on the oppo-site side, see instructions in bag (A).

2

A

1

1

2

1

Page 12: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

12

Fit supporting frame, maintaininga distance of 95 mm to bottomof adjacent tile. Fix remainingframe work. Install windowdirectly on to framing.

Rafter construction with plain tiles andslates. Window recessed max. 25 mm.

820 mm

30-60 mm

60-10

0 mm

max.25 mm

95 m

m

min. 650 mmmax. 720 mm

1310

mm

min

. 108

0 m

mm

ax. 1

180

mm

35°-65°

Page 13: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

13

2

1

Remove transportation battens.

Sash may be removed to facili-tate installation. Release restrictorstay from frame (1). Removescrews in the middle of thehinges and loosen screws at thebottom (2).

2

2

1

Page 14: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

14

Fix bottom brackets with twoscrews (1). Push top adjustablebrackets up towards batten andfix with screws (2).

Position roofing material, main-taining a distance of 60-100 mmfrom bottom frame. Cut the roof-ing material below the window(1). Bend lead apron at the sidesto prevent water penetrating atcorners (2). Unfold foam gasket(3). It may be necessary to fit theoptional tile support providedon a batten at the top of thewindow (4).

2 2

1

3 2

4

1 1 1

1 1

2

60-

100

mm

1

Page 15: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

Position roofing material, main-taining a distance of 30-60 mmat sides of frame and 60-100 mmat top (1). Trim foam gasket atthe sides. Slit foam gasket justabove each tile to allow gasketto seal against underside of tiles(2).

15

30-60 mm

60-1

00 m

m

min. 15 mm

1

2

A

Replace sash and fasten screws(1). Fix restrictor stay (2). If sashis to be positioned on the oppo-site side, see instructions in bag (A).

1

1

2

1 2

Page 16: GVT 154 - Loft Conversions Velux® Windows Dormers Conversion

Min.15 mm

1 2 2 2 3

Soft underroof Hard underroof

Take care to ensure a tight joint between frame rebate and lining, also between lining and ceiling finish (1). Details showing treatment of underfelt, over-window drainage, and fixing of vapour barrier to VELUX lining (2). Distance between flashing and insulation must be min. 15 mm everywhere (3).

English: If you need further informationon installation of this product, please contact VELUX.

Deutsch: Sollten Sie weitere Infor-mationen über den Einbau dieses Produktes wünschen, rufen Sie uns bitte an.

Français : Si vous souhaitez recevoir des informations complémentaires surl’installation de ce produit, veuillezprendre contact avec VELUX.

Dansk: Hvis De ønsker yderligere oplysninger vedrørende montering afdette produkt, kan De kontakte VELUX.

Nederlands: Indien u meer informatieover de inbouw van dit productwenst te ontvangen, neemt u dan gerust contact op met VELUX.

Italiano: Se avete bisogno di ulteriori informazioni sull’installa-zione di questo prodotto, Vi pre-ghiamo di contattare la VELUX.

Español: Si necesita mayor infor-mación sobre la instalación de esteproducto, por favor contacte con VELUX.

A: VELUX Österreich GmbH☎ 02245/32 3 50

AUS: VELUX Australia Pty. Ltd.☎ (02) 9550 3288

B: VELUX Belgium☎ (010) 42.09.09

CDN: VELUX Canada Inc.☎ 1 800 88-VELUX (888-3589)

CH: VELUX Schweiz AG☎ 062/289 44 44

D: VELUX Deutschland GmbH☎ 0180-333 33 99

DK: VELUX Danmark A/S☎ 45 16 45 16

E: VELUX Spain S.A.☎ 91 509 71 00

F: VELUX France☎ 0821 02 15 15 0,119€ TTC/min

FIN: VELUX Suomi Oy☎ 09-887 0520

GB: VELUX Company Ltd.☎ 0870 380 9593

I: VELUX Italia s.p.a.☎ 045/6173666

IRL: VELUX Company Ltd.☎ 01 816 1616

J: VELUX-Japan Ltd.☎ 03-3478-8141

N: VELUX Norge AS☎ 22 51 06 00

NL: VELUX Nederland B.V.☎ 030 - 6 629 629

NZ: VELUX New Zealand Ltd.☎ 09-6344 126

P: VELUX A/S Sucursal em Portugal☎ 21 880 00 60

RA: VELUX Argentina S.A.☎ 0 114 711 5666

RCH:VELUX Chile Limitada☎ 231.18.24

S: VELUX Svenska AB☎ 042/144450

USA: VELUX America Inc.☎ 1-800-88-VELUX

www.VELUX.com

Installation instructions for roof window type GVT 154. Order no. VAS 450097-0504

©1997, 2004 VELUX Group ®VELUX and the VELUX logo are registered trademarks used under licence by the VELUX Group


Recommended