+ All Categories
Home > Documents > H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases...

H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases...

Date post: 18-Jan-2019
Category:
Upload: vukiet
View: 217 times
Download: 0 times
Share this document with a friend
22
Transcript
Page 1: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação
ad
ERT
Page 2: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

H2S

CI2

CO

O2

H2S

CI2

CO

O2

H2S

CI2

CO

O2

EikonSingle Gas Recyclable Monitor

Toxic and oxygen gases

Eikon With two years of maintenance free continuous monitoring in a rugged and robust over mould case, Eikon is fit for purpose in harsh environments.The simplest recyclable on the market with outstanding audible and visual alarms, it provides effective warning of hazardous conditions without the need for training or user interpretation.

Reliable

2 years guaranteed maintenance-free lifeEnd of life indicationConfidence ‘Tap Tap’ test assures correct operation

Alarms

Highly audible 94dB alarmBright, multi-angled LEDs for maximum visibilityDistinctively different alarm tone and self check tone

Rugged

Easy and unobtrusive to wearPatented pocket clip makes sure the unit stays putDust and water tight to IP65

Simple

No parts or servicing neededNo accidental switch off, unit is always onNo training required

ad
ERT
Page 3: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Weight 125g (4.4oz)

Dimensions

(H x W x D)

69 x 63 x 38mm 2.7 x 2.5 x 1.5 inches

Audible Alarms 94dB @ 30cm

Visible Alarms 4 multi-angled red LED

Typical Response

Time

5 seconds

Operating Life Continuously for 2 years. Pull strip to activate.

Self Test/

Confidence

Indicator

Green LED flashes every 15 seconds. A double tap ("Tap/Tap") on a hard surface initiates a self test. An LED sequence and multi-tone bleep is performed upon successful completion. If red LED flashes rapidly the instrument is faulty. In the last week of life, a slow red LED flashes as well as the green confidence LED.

End of Life End of life is indicated by 'n' red LED flashes to indicate 'n' number of weeks of life left

Temperature

Range

-20OC to +50OC (-4OF to +122OF)

Ingress Protection IP65

Humidity 5-95% RH non-condensing

Approval Codes

Europe

International

N. America

ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +50°C)BASEEFA09ATEX0247IECEx BAS 09.0114 Class 1, Div 1 Groups A,B, C, D

Safety Standards

Europe &

International

N. America

EN50014, EN50022, prEn50271UL 913 & CSA 22.2

EMC Compliance EN50270

Accessories Eikon accessory bump test console, commander, swipe cards for commander, mini-printer, printer paper roll, module storage units

Specification: Eikon

www.crowcon.com

Eikon

Crowcon reserves the right to change the design or specification of the product without notice.

Area reserved for distributor stamp

P01018 GB Issue 11, Oct11

Typical ranges and alarms

Gas Range Standard Alarm (UK)

H2S 0-50ppm 5ppm

CO 0-500ppm 30ppm

O2

0-25% VOL 19% VOL

NH3 0-50ppm 25ppm

CI2

0-5ppm 0.5ppm

Eikon is also available in a dual CO/H2S version

Eikon Accessory

This “one touch” bump test solution offers the ability to check Eikon’s status, change alarm level settings, bump and calibrate. Ideal for point of issue use, Eikon accessory is simple and quick to use. Status report commands, like calibration and zeroing, are transmitted with swipe cards for ease of use without a PC. These reports can be printed so the identity of Eikon can be detailed and allows a traceable audit trial.

UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]

US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]

CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected]

Eikon is a range of tough, reliable single gas recyclable monitors designed to withstand the harshest environments with 2 years continuous maintenance-free use.

Part Number Description

C01780 Eikon H2S, 0-50ppm hydrogen sulphide ATEX approved

C01781 Eikon CO, 0-500ppm carbon monoxide ATEX approved

C01782 Eikon O2, 0-25% oxygen ATEX approved

C01809 Eikon CO/H2S carbon monoxide/hydrogen sulphide ATEX approved

C01904 Eikon NH3, 0-50ppm ammonia ATEX approved

C01900 Eikon Cl2, 0-5ppm chlorine ATEX approved

C01870 Eikon H2S, 0-50ppm hydrogen sulphide CSA approved

C01871 Eikon CO, 0-500ppm carbon monoxide CSA approved

C01872 Eikon O2, 0-25% oxygen CSA approved

C01812 Eikon H2S, 0-50ppm hydrogen sulphide UL approved

C01813 Eikon CO, 0-500ppm carbon monoxide UL approved

C01814 Eikon O2, 0-25% oxygen UL approved

C01905 Eikon NH3, 0-50ppm ammonia UL approved

C01901 Eikon Cl2, 0-5ppm chlorine UL approved

Product Ordering Information

ad
ERT Morada
Page 4: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

CO2

H2S

CI2

NH3

O3

CO

O2

CH4

SO2

CO2

H2S

GasmanMonitor de gases individual

para proteção pessoal Gases tóxicos, oxigênio e inflamáveis

Simples Operação com um único botão Visor fácil de ler e com iluminação de fundo para status

de operações e diagnóstico de gases Aviso nítido de necessidade de calibração

Alarmes Alarme sonoro 95dBA Alarme visual duplo vermelho/azul impressionante Alarme interno vibratório 2 níveis de alarme instantâneo e alarmes TWA

para as versões tóxicas

Robusto Revestimento robusto de policarbonato Modelação abrangente fornecendo resistência a fortes impactos Resistente à água e à poeira em conformidade com IP65

Flexível Soluções de sensores de oxigênio, tóxicos e inflamáveis Baterias com versões recarregáveis e de íons de lítio disponíveis Registros extensivos de eventos e dados Módulos de sensores inteligentes e completamente

intercambiáveis

Gasman Com uma construção robusta à prova de impactos e em conformidade com IP65, o Gasman oferece uma vasta gama de gases que inclui seis opções de calibração de inflamáveis.

Projetado para uso nos ambientes mais agressivos, o Gasman fornece uma combinação imbatível de alarmes com iluminação clara e em sons altos com uso de um design extremamente compacto e leve.

SSS

ad
ERT
Page 5: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Especificações:

Gases e faixas As faixas e os alarmes requeridos podem variar de acordo com o país

unidades tóxicas também possuem alarmes Time Weighted Average (TWA – concentração média ponderada pelo tempo).

propano, butano, pentano, hidrogênio e etileno como padrão.

O Gasman também está disponível na versão de área segura de CO2 oferecendo a medição de dióxido de carbono de 0-5%.

Alarmes e faixas típicos

Peso

Dimensões Tempos de resposta típicos (T90)Alarmes sonoros 95 dBA

Diversos sons de alarme permitem uma seleção de tons distintos para níveis de alarmes diferentes

Alarmes visuaisvazamento de gases

Alarme vibratório Alarme vibratório interno Visor

indicação proporcional do tempo restante de operação) e modo de exibição. Indicação na inicialização quando a calibração for

quando algum serviço for necessárioModos de Visor Visor normal para níveis de concentração de gases em tempo

real. Memória de visor para leituras de pico e TWALog de dados

como padrão.

Bateria Bateria de íon de lítio recarregável para todos tipos de gases Bateria de lítio não recarregável para tóxicos e oxigênio (excluindo CO2)

Tempo de operação Não recarregável: Até 2 anos

Observação: O tempo de operação dependerá do padrão de funcionamento e da ocorrências de alarmes. Alarmes frequentes, ou de longa duração, e o uso do bipe de

Amostragem Aspirador manual opcional Temp. operacional faixa

-20°C a +65°C

contato com a Crowcon se as temperaturas operacionais excederem 40°C por períodos longos

Umidade 20-90% UR Proteção contra líquidos e poeira

IP65

Europa

Internacional

EUA

Tóxicos/O2:

Tóxicos/O2:

Europa EUA

Padrões de operação Interface de PC

Calibração O Gasman pode ser calibrado com frequência com o software Portables PC ou utilizando o Checkbox IMH

Acessórios O Gasman é fornecido com um agrafo integral

Acessórios opcionais

Arreios para capacete, placa de arreios universal, alça de ombro, coleira para peito, estojo de couro, conjunto de aspirador

A Crowcon se reserva o direito de alterar o design ou as especificações do produto sem aviso prévio.

UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]

US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]

www.crowcon.com

Gasman

Kit de Teste de Gás O Kit de Teste de Gás fornece uma forma simples e conveniente de realizar um teste de pré-uso de resposta (bump) ou uma calibração.

Opções de recarregamento O Gasman pode ser fornecido com:

Carregador de unidade individual com plugues para Reino Unido, Europa ou EUA ou alimentação cabeada de 110 V/230 V Carregador Comms com opções conforme acima incluindo interface de PC Multicarregador de 5 vias com alimentação universal Adaptador para carregamento em veículos

Area reserved for distributor stamp

Gasman é uma linha de monitores pessoais de gases compactos e robustos que foi projetada para ser usada nos ambientes mais agressivos.

P01019 BR Edição 8, 2010

Gás Faixa Alarme típico (Reino Unido)

Inflamáveis 0-100% LIE 20% LIE

Oxigênio

0-25% 19/23%

Sulfureto de hidrogénio 0-100 ppm 5 ppm

Monóxido de carbono 0-500 ppm 30 ppm

Dióxido de enxofre 0-20 ppm 1 ppm

Cloro 0-20 ppm 0,5 ppm

Dióxido de nitrogênio 0-20 ppm 1 ppm

Amônia 0-100 ppm 25 ppm

Ozônio 0-1 ppm 0,1 ppm

Hidrogênio

0-2000 ppm N/A

Cianeto de hidrogênio 0-25 ppm 5 ppm

Fluoreto de hidrogênio 0-10 ppm 1 ppm

Fosfina 0-5 ppm 0,2 ppm

Flúor 0-1 ppm 0,1 ppm

Fosgênio

0-1 ppm 0,1 ppm

Óxido nítrico

0-100 ppm 25 ppm

Dióxido de carbono

0-5% 0,5 ppm

Códigos de aprovação

Segurança padrão

ad
ERT Morada
Page 6: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

T3 features:

Robust

Tough over-moulded contraction to resist shock and vibration

Water and dust resistant to IP65 and IP67

Alarms

95dB Audible Alarm Piercingly bright red/blue visable alarm Vibrating alarm

4 Gas Personal Monitor

Oxygen, Toxic and Flammable Gases

Proven to serve the needs of today’s most arduous industrial environments.

Designed with the user in mind, the top mount display, full function data and event logs, audible, visual and vibrating alarms deliver top end performance in a small and lightweight package.

Reliable

Proven sensor technology and software operation ‘At a glance’ operating status Clear calibration due warning

Performance

Li-ion battery with at least 14 hours operation True single button operation Easy to read back-lit display for gas readings and diagnostics

CO2

H2S

CI2

NH3

O3

CO

O2

CH4

SO2

CO2

H2S

ad
ERT
Page 7: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

web: www.crowcon.com

UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY

+44 (0) 1235 557700 [email protected]

US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845

+1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam

+31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383

+65 6745 2936 [email protected]

PO1024 GB Issue 7 Jan 2010

Crowcon reserves the right to change the design or specification of this product without notice

Tetra 3 is an intuitive 4 gas personal monitor with a top mount display designed to withstand the harshest of industrial environments.

Gases and Ranges Ranges and alarms may vary by country and application which can be configurated as required. Each channel can have two instantaneous alarms. Toxic channels also have TWA alarms.Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and ethylene as standard.

* T3 is available in a safe area CO2 version offering 0-5% carbon dioxide

measurement. The CO2 sensor replaces the flammable option and can

be supplied with oxygen and toxic sensors.

Gas Range Typical Alarm (UK)

Flam 0-100% LEL 20%O

2 0-25% 19/23.5%

H2S 0-100ppm 5ppm

CO 0-500ppm 30ppmSO

2 0-20ppm 1ppm

O3 0-1ppm 0.1ppm

NH3 0-100ppm 25ppm

*CO2 0-5% 0.5%

WeightDimensions

295g (10.4oz)114 x 71 x 48mm (tapers to 20mm) 4.5 x 2.8 x 1.9 inches

Audible Alarms 95dBMultiple alarm sounds allow selection of distinctive tones for different alarm levels

Visible Alarms Dual colour red/blue flashing LED in gas hazard

Vibrating Alarm Internal vibrating alarm

Display Graphic LCD with backlight, giving simultaneous display for all gas channels. Graphic symbols for battery (with proportional indication of remaining operation time), healthy operation or fault warning. Start up indication when calibration is due, overdue, or service required

Display Mode Normal display for real time gas concentration levels. Display recall for Peak readings and TWA

Datalogging Timed datalogging: 50 hours at 1-minute data rate (3000 records) Threshold logging (starts after adjustable preset level) Event logging: >1500 events

Battery Rechargable Li-ion battery

Operating Time Based on four gas unit with flammable sensor -A 5 hour charge from flat provides at least 10 hours of continuous use. A 12 hour charge provides at least 14 hours of continuous use

Sampling Diffusion or hand aspirator

Operating Temp. Range

-20°C to +55°C (-4°F to +131°F) Toxic and Oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods

Humidity 20-90% RH @ 40°C non-condensing

Ingress Protection IP65 and IP67

Approval Codes Europe

International

North America

ATEX II 2 G Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +55°C)BASEEFA05ATEX0187 IECEx Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +55°C)BAS05.0059 CSA Class I Division 1 Groups A, B, C, D

Safety StandardsEuropeNorth AmericaOperation Standards

EN60079-0, EN60079-11, EN60079-1, 94/9/EC CSA22.2, 152EN50270, EN50271, EN50104, EN45544, EN60079, IEC61508

PC Interface RS232 connection from interface module in charger RS232/USB converter available

Calibration Tetra 3 can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH

Accessories Tetra 3 is supplied with an integral alligator clip

Optional Accessories Universal harness plate, shoulder strap, chest harness, aspirator assembly (flow plate, bulb and 2m/6ft tubing), fixed and telescopic sample probes, and an in-line water trap

Specification

Gas Test Kit The Gas Test Kit provides a simple and convenient means of carrying out either a pre-use (bump) test or a simultaneous four gas calibration (flam, O

2, H

2S, CO only).

Charging OptionsThe T3 can be supplied with: Single way drop in charger with UK,

EU or US plug or in-line 110V/220V supply Single way drop in charger with options

as above including PC interface 5 way multi-charger with universal

power supply Vehicle adapter for in-vehicle charging NEW – Universal charger for vehicle,

wall and desk mounting with a multi-region plug (supplied with EU/UK/US inserts) and status indication

Contact Crowcon for further information.

Area reserved for distributor stamp

ad
ERT Morada
Page 8: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

O2

H2S

CO

CH4

SO2

NH3

CO2

O3

CI2

NO2

Monitor de Entrada

de Espaço Confinado

Detector portátil de 5 gases

Projetado para atender as necessidades de trabalhadores e gerentes encarregados de trabalhos em espaços confinados, o Gas-Pro oferece a detecção de até 5 gases em uma solução compacta e robusta capaz de suportar ambientes agressivos e uso diário.

Flexível +ve SafetyTM personalizado para os requisitos

organizacionais Monitore 5 gases de várias diferentes opções Soluções multiuso; bombeadas e de difusão que oferecem

vários usos em um detector compacto

Solução para Espaços Confinados Display fácil de visualizar posicionado no topo Bomba interna (opção) Reconhecimento automático de falha de fluxo no

adaptador de vazão Modo de pré-entrada específico e único Indicador de status tricolor +ve SafetyTM

(Segurança Positiva) Totalmente revestido por estojo à prova de choque Operação simples por um único botão Soluções de teste de gás portáteis, de parede e de mesa

Gas-Pro

ad
ERT
Page 9: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Área reservado para o selo do distribuidor

Gas-Pro

Monitor de entrada de espaço confinado compacto e robusto capaz de detectar até 5 gases.

UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]

US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]

CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected]

Gases e Faixas Gas-Pro oferece uma vasta gama de sensores, alguns deles são demonstrados abaixo. Gases e faixas podem variar de acordo com o país e aplicação. Cada canal de gás possui dois alarmes instantâneos com canais tóxicos que também contém alarmes TWA.

O Gas-Pro está em estágio de aprovação, portanto os dados incluídos na especificação são padrões, e poderão ser revisados na conclusão

A Crowcon se reserva o direito de alterar o design ou as especificações do produto sem aviso prévio.

Gas Faixa Alarmes

Típicos

Resolução

Tóxico duplo H2S 0-100 ppmCO 0-500 ppm

5 ppm30 ppm

1 ppm1 ppm

Oxigênio 0-25% VOL 19%/23% VOL 0,1% VOL

Inflamável* 0-100% LIE 20% LIE 1% LIE

Dióxido de carbono 0-5% VOL 0,5% VOL 0,01% VOL

Agendado para liberação (entre em contato com a Crowcon para prazo de execução)

Amônia 0-100 ppm 25 ppm 1 ppm

Dióxido de enxofre 0-20 ppm 1 ppm 0.1 ppm

Ozônio 0-1 ppm 0,1 ppm 0,01 ppm

Cloro 0-5 ppm 0,5 ppm 0,1 ppm

Dióxido de cloro 0-1 ppm 0,1 ppm 0,1 ppm

Óxido nítrico 0-100 ppm 25 ppm 1 ppm

Dióxido de nitrogênio

0-20 ppm 1 ppm 0,5 ppm

Especificações:

Tamanho 43 x 130 x 84 mm (1.7 x 5.1 x 3.3)

Peso 309g 4 gases (10.8oz)/340g com bomba (11.9oz) 333g (11.7oz) com bomba (5 gases)/362g com bomba (12.7oz)

Alarmes Sonoro >95dB @ 30 cm (98dB@30 cm em volume alto)Visual – LEDs duplas de todos ângulos vermelha/azul Alerta de vibração

Visor Montagem superior para fácil visualização Com luz de fundo com duas cores (verde/vermelho)

Registro de dados

125hrs em intervalos de 10 segundos (45.000 registros)

Registro de eventos

Alarme, sobre faixa, calibração, bomba, liga/desliga, TWA, 1000 eventos

Bateria Íon de lítio recarregável, >14 hrs (13 hrs de operação bombeada) com base em CH4, O2, H2S, CO O tempo para recarga das baterias menos de 7.5 horas

Amostragem Bomba interna opcional

Temperatura operacional

-20OC a +55OC (-4˚C a +131˚F)+

Armazenamento -25OC a +65OC (-13˚F a +149˚F)

Umidade 10 a 95% RH*+

Proteção contra líquidos e poeira

Testados independetemente para IP65 & IP67

Aprovações (pendentes)

IECEx: Ex ia d IIC T4 Gb Tamb -20˚C a +55˚C ATEX: II 2G Ex ia d IIC T4 Gb Tamb -20˚C a +55˚CUL: Gas detector use in hazardous locations Classe 1, Div. 1, Grupos A, B, C, D only as to intrinsic safety

Conformidade FCC e CE. Em conformidade com a diretiva EMC 2004/108/EC EN50270 e ICED-003

Interface Conexão de dados para soluções de teste de gás e direta ao PC

Carregador/Adaptador

Conecta diretamente com fornecimento de energia de multiregião Adaptador para carregamento em veículos Suporte para mesa Cabo de comunicações e de USB

* Calibrações pellistor disponíveis para metano. Outras calibrações (butano, pentano, propane e etileno) e tipos de gás estão disponíveis, entre em contato com a Crowcon para obter detalhes.

Soluções de Teste de Gás

Soluções para teste de gás no campo e no próprio local, calibração e captura de dados

Q-Test: Teste no próprio campo rápido e fácil I-Test: Estação inteligente de montagem de mesa ou

paredeS-Test: Serviço e manutenção de até 5 detectores

P08013/Edição 1 BP – Setembro 2011

www.crowcon.com

+dependente do sensor de configuração

ad
ERT Morada
Page 10: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

CO2

H2S

CI2

NH3

O3

CO

O2

CH4

SO2

CO2

H2S

TetraPersonal Multigas Monitor

Oxygen, Toxic & Flammable Gases

TETRA

Tetra is a single button, reliable and robust multigas monitor with optional internal pump. Featuring intelligent sensor modules, shockproof construction and self checking software, Tetra is simple to use and assures reliable gas detection in the toughest of environments.

SimpleSingle button operationEasy to read backlit display for gas readings and diagnosticsClear calibration due warningRechargeable Li-ion battery gives 12 hours of continuous operation

AlarmsLoud 94dBA audible alarmUltra bright dual red/blue visual alarmVibrating alarm

RobustRugged plastic housing with flexible internal assembly to resist shock and vibrationDurable over moulded rubber for added protectionWater and dust resistant to IP65

FlexibleOptional built-in pumpRechargeable and alkaline battery versions availableCompatible with Crowcon Portables PC SoftwareFully interchangeable intelligent sensor modules

ad
ERT
Page 11: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Crowcon reserves the right to change the design or specification of the product without notice.

UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]

US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]

www.crowcon.com

Area reserved for distributor stamp

Typical ranges and alarms

Gas Range Standard Alarm (UK)

Flammable 0-100% LEL 20% LEL

Oxygen 0-25% 19/23%

Hydrogen sulphide 0-100ppm 5ppm

Carbon monoxide 0-500ppm 30ppm

Sulphur dioxide 0-20ppm 1ppm

Chlorine 0-20ppm 0.5ppm

Nitrogen dioxide 0-20ppm 1ppm

Ammonia 0-100ppm 25ppm

Ozone* 0-1ppm 0.1ppm

Hydrogen 0-1000pm N/A

Hydrogen cyanide 0-25ppm 5ppm

Hydrogen fluoride 0-10ppm 1ppm

Phosphine 0-5ppm 0.2ppm

Fluorine 0-1ppm 0.1ppm

Phosgene 0-1ppm 0.1ppm

Carbon dioxide 0-5% 0.5%

* unpumped only

Specification:

WeightDimensions

498g (1.1lb) Rechargeable122 x 128 x 57mm (4.75 x 5 x 2.25 inches)Non-rechargeable134 x 128 x 57mm (5.25 x 5 x 2.25 inches)

Typical Response Times (T90)

Flammable 20 s, Toxic gas 20 s, Oxygen 10 s

Audible Alarms 94dBMultiple alarm sounds allow selection of distinctive tones for different alarm levels

Visible Alarms

Vibrating Alarm Internal vibrating alarm

Display 128 x 64 graphic LCD with backlight, giving simultaneous display for all gas channels. Graphic symbols for battery (with proportional indication of remaining operation time), pump operation, healthy operation or fault warning. Start up indication when calibration is due within 30 days, calibration overdue, or service required.

Display Mode Normal display for real time gas concentration levels. Display recall for the Peak readings and TWA.

Datalogging Timed datalogging: 50 hours at 1-minute data rateEvent logging >1500 events

Battery Types Rechargeable Li-ion batteryNon rechargeable pack 3xAA Alkaline cells

Operating Time Rechargeable - 12 hour minimum based on pumped

Sampling Hand aspirator or internal electric sampling pump

Operating Temperature Range

-20OC to +55OC (-4OF to +131OF)Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperature are likely to exceed 40OC (104OF) for extended periods.

Humidity 20-90% RH

Ingress Protection IP65

Approval CodesEurope

International

North America

ATEX II 2G Ex ia d IIC T4 Gb ( -20OC ≤ Ta ≤ 55Oc)BASEEFA 03ATEX0193IECEX Ex ia d IIC T4 Gb ( -20OC ≤ Ta ≤ 55Oc) BAS04.0024CSA UL/cUL Class I Division I Groups A, B, C, D

Safety StandardsEurope

North America

Operation Standards

EN60079-0, EN60079-11, EN60079-1, 94/9/EC

UL913, CSA22.2, 152

EN50270, EN50271, IEC61508, EN61779, EN45544

Calibrations Tetra can be routinely calibrated manually using the menu, using Crowcon Protables PC software or automatically using Checkbox IMH.

Accessories Tetra is supplied with an integral belt/pocket clip. Pumped units are supplied with a sampling kit

Optional Accessories Universal harness plate, shoulder strap, chest

probes and an in-line water trap.

Gases and RangesRequired ranges and alarms may vary by country and application and can be configured as required. Each gas channel can have two instantaneous alarm levels set. Toxic channels also have Time Weighted Average (TWA) alarms.

Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and ethylene as standard.

Tetra is also available in a safe area CO2 version offering 0-5% carbon dioxide

measurement.

TETRATetra is a personal multigas monitor with an optional built-in pump designed to reliably detect gas in the toughest of environments.

PO1017 GB Issue 10 May 2010

PC Interface and CalibrationTetra can be routinely calibrated either manually or by using Crowcon Portables PC software or Checkbox IMH packages, providing the user with full configuration control, calibration and access to data and event logs files. An IR link is available using a RS232/USB connection from the PC.

Charging OptionsThe Tetra can be supplied with:

Plug in charging power supplies with UK, EU or US plug or in-line 110V/230V supply10-way multicharger with 90-260V in-line power supply with either UK, EU or US mains leadVehicle lighter socket charger for in-vehicle charging

Gas Test KitThe Gas Test Kit provides a simple and convenient means of carrying out either a pre-use (bump) test or a simultaneous four gas calibration (flammable, oxygen, hydrogen sulphide and carbon monoxide only).

ad
ERT Morada
Page 12: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

CO2

H2S

CI2

NH3

O3

CO

O2

CH4

SO2

CO2

H2S

Triple Plus+ features:

Rugged construction

Triax™ casing will not crack or shatter when dropped Unique internal design will resist the harshest treatment

Full buoyancy makes recovery from water possible

Flexible

Available for diffusion, manual aspiration or pumped sampling

Interchangeable sensor modules Comprehensive datalogging with site and user names

Portable Monitor

Oxygen, Toxic and Flammable Gases

Triple Plus+With over 60,000 units in use worldwide, our customers have come to depend on the robust and reliable performance of the Triple Plus+.

The extremely durable Triax™ case and internal construction makes the Triple Plus+ an industry favourite known for the ability to withstand even the most demanding of applications.

Benefits

Simple customisation to alternative flammable gas correction factors

Wide range of sensor types allowing 4 gas detection QuickCal – simple rapid calibration Peak hold capability for pre-entry checks

Convenient and simple to use

Large four channel simultaneous gas display Piercing 85dBA @ 1m Ultra bright LED alarms with top visibility Confidence blip, low battery and TWA warnings Simple Windows™ software interface

Triple Plus+

ad
ERT
Page 13: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Area reserved for distributor stamp

P01005 GB Issue 11 02/10

Triple Plus+ is a 4 gas personal monitor for oxygen, toxic and flammable gases used for personal safety around the globe.

Gases and RangesRanges and alarms may vary by country and application which may be configured as required. Each channel can have up to three levels of alarm, including short and long TWA exposure levels for Toxic channels.

A choice of 12 flammable correction factors are available via Portables PC.

Other sensors may be available.

Gas Range Typical Alarm (UK)

Flam 0-100% LEL 20% LELH

2 (electrochem)

0-100% LEL 20% LEL

CH4

0-100% vol -O

2 0-25% 19%/23%

H2S 0-50ppm 5ppm

CO 0-500ppm 30ppmSO

2 0-10ppm 1ppm

Cl2

* 0-5ppm 0.5ppmNO

2 0-10ppm 1ppm

PH3

0-2ppm 0.1ppmNH

3 0-50ppm 25ppm

H2 (non-Flammable) 0-2000ppm N/A

HCN 0-25ppm 10ppmHCl 0-10ppm 1ppmF

2 0-10ppm 1ppm

HF

0-10ppm 2ppmETO

0-10ppm 5ppm

ClO2

0-1ppm 0.1ppmNO

0-100ppm 25ppm

WeightDimensions

880 g (1.9 lb)118 x 200 x 73mm (h x w x d) (4.65 x 7.8 x 2.9 inches) including strap hooks

Approval Codes EuropeNorth America

ATEX II 2G: Ex ib d IIC T4 GbClass I Division 1, Groups A, B, C, D

Safety StandardsEurope

North America

EN50014, EN50020, 94/9/EC, SFA3009, EN50081-2, EN50270, EN50082-2 UL 913, CSA 22.2 No.157

Ingress Protection IP65

Typical response times Methane 20 s, Oxygen 10 s, Typical Toxic Gas 20 s

Expected sensor life Flammable 5 years, Toxic 3 years, Oxygen 2 years

Audible Alarms Piercing, rapid intermittent, piezo-electric tone,85 dBA at 1 mConfidence blip (selectable)Distinctive double blip for low battery with user accept

Visible Alarms Ultra bright flashing red LED in gas hazardSlow flashing green LED indicates instrument is workingDistinctive double flash of green LED indicates low battery

Display 2 lines of 24 characters, dot matrix high contrastLCD with back light operating for 30 minutes.Values and units for up to 4 gases displayedsimultaneously at current, TWA or peak levels.Low battery, pump failure, real time and elapsedtime, calibration and configuration data also displayed

Datalogging Adjustable sample rate, 100 hours @ 1 minute samplerate (maximum 6000 data points per channel),logging of events, user and site

NEW LIBRA Li-Ion rechargeable battery pack Battery Life:Standard instrument >12 hoursPumped instrument >10 hours

Battery Charging Dual rate ‘drop in’ chargerDual rate charger/PC interface

Electric pump Optional internal pump with on/off button

Operating Temp. Range -20°C to +50°C (-4°F to 122°F)

Humidity 20–90% RH non-condensing

PC Interface RS232 connection via the interface charger. RS232/USB converter available.Portables PC also controls datalogging, giving the user a choice of direct graphical output or a datafile compatible with all leading spreadsheets

Calibration Triple Plus+ can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH

Accessories Supplied as standard: manual, shoulder strap and allen keys (pumped units include additional flow plate, 2m hose and pouch)

Optional Accessories Leather carry case, straight and telescopic probes, water trap, baffle plate, aspirator, calibration flow adaptor and hose

SpecificationTriple Plus+

Crowcon reserves the right to change the design or specification of this product without notice

web: www.crowcon.com UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY

+44 (0) 1235 557700 [email protected]

US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383

+65 6745 2936 [email protected]

Charging OptionsThe Triple Plus+ has two dual rate charging solutions supplied with UK, EU, US plug and without plug configurations. A vehicle adapter for in-vehicle charging is also available.

Standard drop in charging cradlePC interface charger

NEW LIBRA Li-Ion Battery PackAvailable in new builds from April , the new LIBRA battery pack offers extended lifetime and charge cycles. Also designed to replace lead acid batteries in existing units, the LIBRA has solved the reduced lifetime effects of changes in Lead Acid technology during recent years. Compatible with Triple Plus+ and Triple Plus+ IR units whist maintaining certification levels, the LIBRA charges with the existing charger units and takes only seconds to replace.

Contact Crowcon for further information.

*Unpumped units only

ad
ERT Morada
Page 14: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

CO2

H2S

CI2

NH3

O3

CO

O2

CH4

SO2

CO2

H2S

Triple Plus + IR features:

Rugged construction

Triax™ casing will not crack or shatter when dropped Unique internal design will resist the harshest treatment

Full buoyancy makes recovery from water possible

Flexible

Available for diffusion, manual aspiration or pumped sampling

Interchangeable sensor modules Comprehensive datalogging with site and user names

Portable Monitor

Flammable Hydrocarbons Carbon Dioxide, Oxygen,

and Toxic Gases

Triple Plus+ IRIncorporating infrared detection technology the Triple Plus+ IR extends the capability of the Triple Plus family of products allowing extended life detection of hydrocarbons and carbon dioxide.

The infrared hydrocarbon sensor offers measurement in inert backgrounds at both %LEL and %volume levels for tank purging and inert atmosphere monitoring.

Infrared hydrocarbon sensor benefits

Volume % measurement for purging applications %LEL measurement in air or inert backgrounds Single or dual range measurement No poisoning effects Reduced cost of ownership – long life sensor and no burnout IR CO

2 detection, 0–2%

Convenient and simple to use

Large four channel simultaneous gas display Piercing 85dBA @ 1m Ultra bright LED alarms with top visibility Confidence blip, low battery and TWA warnings Simple Windows™ software interface

Triple Plus+ IR

ad
ERT
Page 15: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Area reserved for distributor stampweb: www.crowcon.com UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY

+44 (0) 1235 557700 [email protected]

US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383

+65 6745 2936 [email protected]

P01014GB Issue 9 10/10

Triple Plus+ IR is a 4 channel personal monitor for flammable hydrocarbons, oxygen and toxic gases offering single or dual flammable ranges.

Gases and RangesRanges and alarms may vary by country and application which may be configured as required. Each channel can have up to three levels of alarm, including short and long TWA exposure levels for Toxic channels. Flammable sensors are offered as a single (0-100% LEL) or dual range (0-100% LEL and 0-100% Volume) which occupies two channels.

Flammable gas calibrations are available for methane, butane, acetylene, pentane (% LEL only), propane and ethylene. Other sensors may be available.

A CO2 IR sensor can be fitted in the place of the Flammable IR sensor

(only one IR sensor may be fitted in the unit).

Gas Range Typical Alarm (UK)

Flam 0-100% LEL 20% LELFlam 0-100% vol No alarmCO

2 0-2% 0.5/1.5%

O2 0-25% 19%/23%

H2S 0-50ppm 5ppm

CO 0-500ppm 30ppmSO

2 0-10ppm 1ppm

Cl2* 0-5ppm 0.5ppm

NO2 0-10ppm 1ppm

PH3

0-2ppm 0.1ppmNH

3 0-50ppm 25ppm

H2 (non-Flammable) 0-2000ppm N/A

HCN 0-25ppm 10ppmHCl 0-10ppm 1ppm

WeightDimensions

880 g (1.9 lb)118 x 200 x 73mm (h x w x d) (4.65 x 7.8 x 2.9 inches) including strap hooks

Approval Codes EuropeNorth America

ATEX II 2G: Ex ib d IIC T4 GbClass I Division 1, Groups A, B, C, D

Safety StandardsEurope

North America

EN50014, EN50020, 94/9/EC, EN50081-2, EN50270, EN50082-2, EN50270 UL 913, CSA 22.2 No.157

Ingress Protection IP65

Typical response times IR 20 s, Oxygen 10 s, Typical Toxic Gas 20 s

Expected sensor life IR 5 years, Toxic 3 years, Oxygen 2 years

Audible Alarms Piercing, rapid intermittent, piezo-electric tone,85 dBA at 1 mConfidence blip (selectable)Distinctive double blip for low battery with user accept

Visible Alarms Ultra bright flashing red LED in gas hazardSlow flashing green LED indicates instrument is workingDistinctive double flash of green LED indicates low battery

Display 2 lines of 24 characters, dot matrix high contrastLCD with back light operating for 30 minutes.Values and units for up to 4 gases displayedsimultaneously at current, TWA or peak levels.Low battery, pump failure, real time and elapsedtime, calibration and configuration data also displayed

Datalogging Adjustable sample rate, 100 hours @ 1 minute samplerate (maximum 6000 data points per channel),logging of events, user and site

NEW LIBRA Li-Ion rechargeable battery pack Battery Life:Standard instrument >12 hoursPumped instrument >10 hours

Battery Charging Dual rate ‘drop in’ chargerDual rate charger/PC interface

Electric Pump Optional internal pump with on/off button

Operating Temp. Range -20°C to +50°C (-4°F to 122°F)

Humidity 20–90% RH non-condensing

PC Interface RS232 connection via the interface charger. RS232/USB converter available.Portables PC also controls datalogging, giving the user a choice of direct graphical output or a datafile compatible with all leading spreadsheets

Calibration Triple Plus+ IR can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH

Accessories Supplied as standard: manual, shoulder strap and allen keys (pumped units include additional flow plate, 2m hose and pouch)

Optional Accessories Leather carry case, straight and telescopic probes, water trap, baffle plate, aspirator, calibration flow adaptor and hose

Specification

Charging OptionsThe Triple Plus+ IR has two dual rate charging solutions supplied with UK, EU, US plug and without plug configurations. A vehicle adapter for in-vehicle charging is also available.

Standard drop in charging cradlePC interface charger

NEW LIBRA Li-Ion Battery PackAvailable in new builds from April, the new LIBRA battery pack offers extended lifetime and charge cycles. Also designed to replace lead acid batteries in existing units, the LIBRA has solved the reduced lifetime effects of changes in Lead Acid technology during recent years. Compatible with Triple Plus+ and Triple Plus+ IR units whist maintaining certification levels, the LIBRA charges with the existing charger units and takes only seconds to replace.

Contact Crowcon for further information.

Triple Plus+ IR

Crowcon reserves the right to change the design or specification of this product without notice

*Unpumped units only

ad
ERT Morada
Page 16: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Transportable Multi-gas area monitor

Used singly or linked together, Detective+ gives a loud and clear alarm providing effective warning of gas hazards. The rugged, water and impact resistant design and clear display make Detective+ the ideal choice for your transportable gas detection needs.

Superb pedigree Detective+ is based on the highly

successful Triple Plus+ multi-gas monitor which has sold over 55,000 units worldwide

Versatile and user friendly Infra-red sensors available

- allows sampling of potentially high - flammable gas levels and CO2- infra-red sensors are unaffected by - poisoning

Built-in pump option provides fast response and extra sensor protection

Display provides clear information, allows identification of gas hazard

Easy tracking of multiple hazards up to 60 hour battery operation Wide range of toxic gas sensors

available

Extremely loud and clear alarms Wailing omni-directional siren,

104 dBA @1 metre High intensity red LED clusters provide

visual alarm indication All linked Detective+ units indicate an

alarm sensed by any one unit Units actually sensing alarm have faster

LED flash Audible and visible confidence blip Time weighted average alarms for 8

hours and 15 minutes averages

Uniquely rugged, tripod construction Detectors are fully protected, even if

device is overturned Raised detectors prevent water ingress Easy and quick to set up Folding or fixed leg options provide easy

storage and transportation

A transportable area monitor you can trust+Detective

monitor

ad
ERT
Page 17: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Transportable multi-gas monitor

Weight 7.5 kg (19lb)

Dimensions 640 h x 455 w x 455 d mm (25.2 x 17.9 x 17.9 inches)

Typical measuring Standard Typical Alarm ranges and alarm Range Levels settings Flammable gas 0 – 100% LEL 20% LEL (up to four gas Oxygen 0 – 25% 19% & 23% measurement channels) Hydrogen sulphide 0 – 50 ppm 10 ppm Carbon monoxide 0 – 500 ppm 35 ppm Sulphur dioxide 0 – 10 ppm 2 ppm Chlorine* 0 – 5 ppm 0.5 ppm Nitrogen dioxide 0 – 10 ppm 2 ppm Phosphine 0 – 5 ppm 0.5 ppm Ammonia 0 – 50 ppm 25 ppm Ammonia 0 – 1000 ppm N/A Hydrogen (non- 0 – 2000 ppm N/A flammable levels) Hydrogen cyanide 0 – 25 ppm 10 ppm Hydrogen chloride 0 – 10 ppm 5 ppm Chlorine Dioxide 0-1ppm 0.1ppm Hydrogen Fluoride 0-10ppm 1pm Ethylene Oxide 0-10ppm 5ppm Volatile Organic 0-100ppm N/A Required ranges and alarms may vary by countryand application and these can be configured as required. Infrared Sensors Infrared sensors for flammable gas can be supplied as a single range, 0-100% LEL, utilising a single display channel, or as a dual range, 0-100% LEL/0- 100% volume, which then occupies two display channels. CO2 sensors are supplied as 0-5% volume. Only one IR sensor can be fitted, and IR sensors can only be used in combination with oxygen and toxic sensors

Standard Range Typical Alarm Flammable Gas 0-100% LEL 20% LEL Flammable Gas 0-100% v/v None Flammable Gas available for methane, propane, butane or ethylene CO2 0-5.0% v/v 0.5/1.5% v/v

Typical response times Methane 20 s, Oxygen 10 s, typical toxic gas 20 s, IR 30 s

Expected sensor life Flammable 5 years, Toxic 3 years, Oxygen 2 year minimum, IR >5 years

Audible alarms Wailing, omni-directional siren, 104 dBA @ 1 metre.

Visible alarms Three large, top-mounted red LED clusters and single red LED on control panel. In alarm mode LED clusters flash in quick succession LED clusters of linked Detectives repeating the alarm, flash more slowly than LED lights on those Detectives sensing the hazard. Slow flashing green LED indicates normal working. Rapid flashing green LED indicates low battery.

Display High contrast LCD with back light 2 lines of 24 characters. Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels. Low battery, real time and elapsed time, calibration and configuration data also displayed

Datalogging Adjustable sample rate, 100 hours @ 1 minute sample rate (maximum 6000 data points per

channel) Logging of events, user and site data

Menu Operating menu allows access to setting up of instrument operation Log Menu allows selection of Users and Sites from predefined lists, marking the log file with an event, and start or stop of data logging Configuration Menu allows selection of display and alarm modes, setting of alarms, zero and calibration, and selection of flammable gas correction factors from predefined list .

Battery 6 V, 7.2 Ah Sealed lead acid battery pack Optional 6V, 12Ah high capacity pack

Battery life Standard instrument: Up to 36 hours assuming flammable/CO2 sensor fitted with 7.2Ah battery. Up to 60 hours with optional 12Ah battery pack

Battery charging Built-in battery charging circuit, dual rate 100 – 120 VAC and 200 - 250 V AC Input options available. (Safe Area operation only) Typical charge time: 12 hours

Operating Temp. range -20°C to +40°C (-4°F to 104°F). Toxic and Oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods.

Humidity 0 – 95% RH non condensing

Approvals Europe : ATEX II 2G EEx ib d IIC T4 USA and Canada : Class 1 Division 1 Groups A, B, C, D (Pending)

Standards EN50014, EN50018, EN50020, EN50104, EN45544, UL913 (Pending)

Ingress protection IP65

EMC EN 50270, FCC CFR47 Part 15, IC ICES03

PC Interface Detective+ has an in-built PC interface, which can be connected to the serial port of a computer using the optional RS232 lead. Portables PC software can be used to set alarms, clock, datalogging interval and password. Portables PC also controls datalogging, giving graphical display of instrument log file and allows file export to spreadsheet.

Calibration Detective+ can be routinely calibrated quickly using its internal menu command, Portables PC or the Crowcon CheckBox IMH management system

Accessories Baffle plate (to protect sensors) Interconnecting lead - 10 m standard, longer lengths up to 100m available Computer lead - RS232 serial link Portables PC software Aspirator Manual bulb and 2 m hose, both non- absorbent and hydrocarbon resistant Internal electric sampling pump option includes external water trap and 2m hose, longer lengths available on request

Linked Detectives Up to 12 units can be linked to provide perimeter or area monitoring

Specification

P01025GB Issue 2 07/09

Crowcon reserves the right to change the design or specification of this product without notice

UK OfficeCrowcon Detection Instruments Ltd2 Blacklands WayAbingdon Business ParkAbingdonOxfordshire OX14 1DYUnited KingdomTel: +44 (0) 1235 557700Fax: +44 (0) 1235 557718Email: [email protected] Site: www.crowcon.com

USA OfficeCrowcon Detection Instruments Ltd21 Kenton Lands RoadErlangerKentucky 41018-1845USATel: +1 859 957 1039 or 1-800-5-CROWCONFax: +1 859 957 1044Email: [email protected] Site: www.crowcon.us

Detective+

ad
ERT Morada
Page 18: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

C2H5OH

C2H6

C3H8

C4H10

C5H12

C6H14

CH4

C7H16

C2H4

C3H6

Hydrocarbon gas detector

for leak survey and localisation

Gas-Tec

Based on the tried, tested and trusted Gas-Tec engine

Simple and intuitive functionality utilising LCD and softkey technology

Rechargeable Li-Ion battery offers more than 22 hours operation

Enhanced electronic controls reduce hydrogen usage

Full data and event logging with simple drag and drop download

GPS logging for accurate location report of leaks.

Gas-Tec is a portable gas detector for rapid survey and leak localisation. GPS, data and event logging allow survey teams to track progress and pinpoint areas of significant interest. Gas-Tec is worn over the shoulder and has a wide range of probes and accessories for all applications.

Gas-Tec

Flame Ionisation Detector offering ppm level indication

ad
ERT
Page 19: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

Area reserved for distributor stamp

Gas-Tec is the next generation of flame ionisation detection. Offering users enhanced technology, Gas-Tec is the unique surveying solution.

UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]

US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]

www.crowcon.com

GPS: Enhances record keeping by assigning latitude, longitude and sea level to data readings. Users are also able to view the current location, offering the precise location to back-up crews for immediate leak management.

Data and event logging: Gas-Tec allows users the ability to download full survey information via the ‘drag and drop’ USB interface for survey traceability.

Intuitive functionality: LCD and soft keys offering full sequence instruction, in-operation options, service and calibration set-up and alerts.

Tried and tested: Based around the original Gas-Tec ‘engine’ detection method. The next generation is therefore already proven, fit for purpose and suited to the trials of every day use.

Rugged and reliable: Ingress protected to IP54 for everyday use in all weather conditions.

Enhanced electronic controls: Offering extended battery and cylinder life. Pressure and flow transducers manage H2

and sample flow rates.

Gas-Tec Accessories:

Trigger Survey Kit: in-vehicle leak survey tool allowing detection up to 30km/hr.

Earphones: allow users to hear alarms in noisy areas and traffic.

Spare H2 Cylinders: offer extended usage in the field and reduce

the need for regular refills.

Probe Assemblies: suitable for all applications. Bore hole, straight probe, cup attachment and detection trolley.

Vehicle Charger: allowing on the move charging to maintain battery levels between surveys.

Gas-Tec is supplied as standard in a wheeled ABS case withfitted foam insert.

P01107GB Issue 3 03/2011Crowcon reserves the right to change the design or specification of the product without notice.

Specifications:

Description Hydrocarbon gas detector

Sensor Flame Ionisation Detection (FID)

GasCalibrated to Methane (CH

4)

Other correction factors available

Range0 – 100 ppm0 – 1000 ppm0 – 10,000 ppm

Accuracy +/- 10%

Response time <2 seconds

Hydrogen cylinder life

UK & EU 400ml = 45 hrsEU 100ml = 11 hrsUSA 300ml = 33 hrs

CaseHigh impact and UV resistant glass reinforced nylon

Size 385 x 205 x 125 mm (15.2 x 8 x 5 Inches)

Weight 2.4kg without bottle (5.3lb)

Ingress protection IP54

Audible alarm Rising tick increasing with presence of gas

Visual alarms On LCD indication of status

Backlight Adjustable intensity and time off delay

Battery type Rechargeable Lithium-ion

Battery life 22 hrs

Recharge time 2.5 hrs

Operating temperature range

-5⁰C to +55⁰C (23⁰F to 131⁰F)

Humidity 20 to 95% RH non-condensing

Sample input Via quick connect filtered coupling

Outputs Headphone, USB and Trigger sockets

Data / Event / GPS logging

21 million log entries giving over 700 days logging activity (assuming logging at 1 second intervals over an 8 hour shift)

GPS Accurate to within 10m with 5 satellite lock

EMC & approvals EN50270 & EN50271:2002

Industry approvals FCC and CE marked

Calibration period Recommended every 6 months

Warranty12 months against faulty components or manufacture

ad
ERT Morada
Page 20: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

LaserMethane®mini Gen2Deteção de metano à distância

LaserMethane® mini Gen2

A segunda geração do LaserMethane® mini Gen2 daCrowcon está mudando a forma como os vazamentos de metano podem ser detectados.

Utilizando a tecnologia de laser, o LaserMethane® mini Gen2 (LMm) permite aos usuários detectar metano de maneira confiável e precisa, a uma distância segura.

Obtenha resultados em segundos simplesmente apontando o feixe de laser em direção ao vazamento suspeito ou ao longo da linha de inspeção. Esse processo elimina a necessidade de acesso a áreas cercadas, em grandes alturas ou outras áreas difíceis de alcançar.

Segurança em primeiro lugar

Medição e detecção remotas a até 100 metrosNão é necessário nenhum especialista ou equipamento de acesso especial para detectar vazamentosAprovado pela ATEX para uso industrial e agora inclui aplicações de mineração

Fácil de usar

Portátil – realmente fácil de transportarProjeto leve, compacto e robustoMenu intuitivoMostrador gráfico ou numérico totalmente colorido

Flexível e conveniente

Níveis de compensação e alarme programáveis pelo usuárioBateria de longa duração – permite 6 horas de operação contínua com uma bateriaA verificação e a calibração automáticas ao ligar o detector economizam tempo e garantem a confiabilidade e um desempenho alto e consistente

Precisão e confiabilidade

Responde especificamente ao metanoPrecisão excepcional – detecta até mesmo níveis muito baixos de metanoBaixo Tempo de Resposta - normalmente 0,1 segundo

Laser

A seguCrowcopodem

Utilizanpermitprecisa

Obtenhde lasede inspcercada

ad
ERT
Page 21: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação

www.crowcon.com

Área reservada para o carimbo do distribuidor

Tamanho 70 x 179 x 42 mm, LxPxA

Peso 600 g (1.3 lb), incluindo a bateria

Gás alvo Metano (CH4)

Método de detecção Espectroscópio de absorção a laser de diodo regulável (TDLAS)

Distância de

detecção

Modo padrão 30 m Até 100 m com refletor

Faixa de medição 1 – 50.000 ppm.m (dependendo do objeto refletore da distância de detecção)

Precisão da medição ±10% @ 100 ppm.m (2 m)±10% @ 1000 ppm.m (2 m)

Velocidade de

detecção

0,1 segundo (aprox.)

Alarme sonoro 72 dB a 76 dB @ 0,3 m e dependente do ângulo

Aviso de reflexão Aviso de reflexão insuficiente, áudio e visual

Mostrador Totalmente colorido e eletroluminescente

Operação Funções por menu no display

Bateria Recarregável de hidreto metálico de níquel

Tempo de operação

(laser ligado)

Mínimo de 6 horas por carga (recarga de 4 horas) @ 25 °C no nível 5 do mostrador

Temperatura de

operação

-17 °C 50 °C

Umidade de operação 30% a 90% UR

ATEX Corpo principal:

II 2G Ex ib op-pr/op-is IIA T1

I M2 Ex ib op-pr/op-is IIA I

Conjunto de baterias:j

II 2G Ex ib IIA T1

I M2 Ex ib IIA I

Proteção de entrada IP54

CE CE 0344

EMC EN61326-1 : 2006

Segurança do laser IEC 60825-1 : 2001

Laser marcador: Comprimento de onda de saída de 650 nmNível de saída: 1 mW (Classe 2) ou menos

Laser de detecção:

Comprimento de onda de saída de 1653 nmNível de saída: 10 mW (Classe 1) ou menos

Cuidado! NUNCA OLHE PARA O FEIXE DE LASER.

Nunca aponte esse detector em direção ao sol.

Produto padrão

fornecido com:

Carregador da bateriaManual do operador (Inglês, Japonês e Português como padrão)Bateria recarregávelAlçaCapa de proteção

Extras opcionais Estojo de transporteBateria extraÓculos de aprimoramento do laser

LaserMethane® mini Gen2

M07688 BP edição 4 11/11

Aplicações típicas

Metano além do alcance, isto é, áreas difíceis de alcançar ou inacessíveisMonitoramento de grandes áreas, por exemplo, inspeção de tubulaçõesMonitoramento de áreas perigosas, por exemplo, refinarias petroquímicasPrevenção de desastres secundários, por exemplo, nuvens de gás acumuladas em espaços no teto de prédios em propriedades comerciais e industriaisDetecção de metano através de janelas ou caixas de correspondência de propriedades desocupadas

Consulte o guia de aplicação do LaserMethane® para obter mais informações.

Especificação

As informações aqui contidas estão corretas no momento da impressão e estão sujeitas a alteração sem notificação prévia. Todas as informações aqui contidas foram impressas de acordo com o fabricante.

O LaserMethane® mini Gen2 da Crowcon detecta com precisão e confiabilidade vazamentos de gás à distância. O que era uma atividade que demandava tempo e recursos, agora pode ser concluída em questão de segundos.

Princípio de medição

Ao apontar o LaserMethane® mini Gen2 para um vazamento suspeito ou área de inspeção como uma tubulação de gás ou teto, a concentração de metano é medida através da detecção da diferença entre a luz emitida e a luz recebida.

Para obter alta seletividade e sensibilidade de detecção para o metano, o LaserMethane® mini Gen2 usa um comprimento de onda que apresenta adsorção máxima e é exclusivo para metano.

A densidade da coluna de metano é a concentração do metano entre o detector e o alvo e é o produto da concentração da nuvem de metano (ppm.m) e o comprimento do caminho que atravessa a nuvem (metros) e é relatado em unidades ppm.m.

Laser de medição

Laser de reflexão

Gás metanoAlvo

Detetor LaserMethane® mini Gen2

RU: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected]

EUA: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected]

NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected]

SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected]

CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected]

ad
ERT Morada
Page 22: H S CI - ERT · CO 2 H 2 S CI 2 NH 3 O 3 CO O 2 CH 4 SO 2 CO 2 H 2 S Gasman Monitor de gases individual para proteção pessoal Gases tóxicos, oxigênio e inflamáveis Simples Operação
ad
ERT Morada

Recommended