HA/LP ® High Altitude/Low Profile Oxygen Mask GENTEX High Altitude/Low Profile (HA/LP ® ) Oxygen Masks are designed for use in both pressure breathing for G (PBG) equipped high performance fighter/attack aircraft and Non-PBG equipped aircraft. HA/LP Oxygen Masks are used by the United States and Foreign Military Services throughout the world. The HA/LP Oxygen Masks are derivatives of the USAF MBU-20/P Oxygen Mask. HA/LP PBG Oxygen Masks provide a bladder supply hose that connects the mask assembly to an occipital bladder in the helmet to provide automatic mask tensioning during high G flight. The Non-PBG HA/LP Oxygen Masks are direct replacements for both MBU-12/P and MBU-5/P Masks. Similar to the MBU-20/P, the HA/LP Oxygen Masks provide +600 knot windblast protection. The lightweight, low-profile mask design provides optimal positive pressure breathing (PPB) sealing capabilities. Separate inhalation and exhalation valves minimize breathing resistance thus reducing aircrew fatigue. The masks utilize a lightweight hardshell that may be custom-trimmed to allow optimum comfort while maintaining appropriate fit. FSC# 27541 Transaero, inc. 35 Melville Park Road, Suite 100 Melville, NY, USA 11747 T 631.752.1240 F 631.752.1242 transaeroinc.com 6/09
Transcript
Page 1: HA/LP High Altitude/Low Profile Oxygen MaskThe Non-PBG HA/LP Oxygen Masks are direct replacements for both MBU-12/P and MBU-5/P Masks. Similar to the MBU-20/P, the HA/LP Oxygen Masks

HA/LP® High Altitude/Low Profile Oxygen Mask

GENTEX High Altitude/Low Profile (HA/LP®)

Oxygen Masks are designed for use in both

pressure breathing for G (PBG) equipped high

performance fighter/attack aircraft and Non-PBG

equipped aircraft. HA/LP Oxygen Masks are

used by the United States and Foreign Military

Services throughout the world.

The HA/LP Oxygen Masks are derivatives of the

USAF MBU-20/P Oxygen Mask. HA/LP PBG

Oxygen Masks provide a bladder supply hose

that connects the mask assembly to an occipital

bladder in the helmet to provide automatic mask

tensioning during high G flight. The Non-PBG

HA/LP Oxygen Masks are direct replacements

for both MBU-12/P and MBU-5/P Masks.

Similar to the MBU-20/P, the HA/LP Oxygen

Masks provide +600 knot windblast protection.

The lightweight, low-profile mask design provides

optimal positive pressure breathing (PPB) sealing

capabilities. Separate inhalation and exhalation

valves minimize breathing resistance thus reducing

aircrew fatigue.

The masks utilize a lightweight hardshell that

may be custom-trimmed to allow optimum comfort

while maintaining appropriate fit.

FSC# 27541

Transaero, inc.

35 Melville Park Road, Suite 100

Melville, NY, USA 11747

T 631.752.1240 F 631.752.1242

transaeroinc.com

6/09

Page 2: HA/LP High Altitude/Low Profile Oxygen MaskThe Non-PBG HA/LP Oxygen Masks are direct replacements for both MBU-12/P and MBU-5/P Masks. Similar to the MBU-20/P, the HA/LP Oxygen Masks

631.752.1240

transaeroinc.com

Non-PBG HA/LP Masks

P/N NSN Description

G010-1190-01 1660-01-390-1547 small narrow

G010-1190-02 1660-01-390-1543 medium narrow

G010-1190-03 1660-01-390-1544 medium wide

G010-1190-04 1660-01-390-1548 large wide

G010-1336-01 N/A extra small narrow

Parts breakdown, G010-1190-01/04 Non-PBG HA/LP Masks

P/N NSN Description

1 G010-2014-01 N/A upper strap assy

2 G030-1080-02 5965-01-469-9770 microphone assy,

M-169A/AIC, modified

3 G010-1210-01 1660-01-447-3402 exhalation valve occluder

4 G012-1034-02 3895-01-439-1315 guide, cable-upper

5 G012-1035-02 1660-01-067-7615 guide, cable-lower

6 MS3367-1-0 5975-00-984-6582 tiedown strap (not shown)

6a G012-1033-01 4730-00-943-3359 clamp, hose, 2-position

(not shown)

7 G012-9025-01 5995-01 269-5936 cord and plug assy

(CX-4707C/AIC)

8 G002-1001-01 1660-00-730-2247 connector, 3-pin

9 G010-1191-01/04 N/A facepiece, SN, MN, MW, LW

10 G010-1025-01 4720-01-440-4277 breathing hose

11 G013-1000-01 1660-01-317-0250 bayonet assy, left

12 G013-1000-02 1660-01-317-8339 bayonet assy, right

13 G010-1086-01 N/A exhalation valve assy

14 G010-1050-03 4820-01-317-5613 inhalation valve assy

15 G010-1187-21/24 N/A hardshell assy,

SN, MN, MW, LW

16 G010-1044-01 N/A non-PBG HA/LP

conversion kit with plastic

QD (optional-not shown)

17 G010-1238-05 1660-01-480-6662 hardshell assy, XSN

(not shown)

18 G010-1246-01 1660-01-480-6669 facepiece, XSN (not shown)

The silicone rubber facepiece incorporates a reflective

seal design for optimum sealing capabilities, and a

chin cup which provides injury protection during high

speed or high altitude ejection.

The extra small narrow hardshell and facepiece have

reduced height and width dimensions compared to the

existing Small Narrow MBU-20/P and HA/LP Mask.


Recommended