5000 WESTOWN PARKWAY SUITE 400 | WEST DES MOINES, IA 50266-5921 P 515.223.4000 | F 515.222.5220 | KNAPPPROPERTIES.COMKNAPP PROPERTIES, AND ALL AGENTS WHOSE LICENSES ARE HELD BY KNAPP PROPERTIES, ARE LICENSED IN THE STATE OF IOWA. INFORMATION CONTAINED HERE DEEMED RELIABLE BUT NOT GUARANTEED BY KNAPP PROPERTIES.
LISTING BROKERKnapp Properties EXCLUSIVELY MARKETED BYBen Garrett 515.401.7071 Brian Erickson, CCIM 515.202.5035
FOR SUB-LEASE8,563 square foot suite located in the popular Harding Hills Shopping Center.
Recently updated interior with several private exam rooms/offices and ample storage space.
Hy-Vee anchored shopping center.
PRICING
• $12.00 PSF/YR NNN
HARDING HILLSSHOPPING CENTER3420-3452 MLK PKWY SUITE 100,DES MOINES, IA
Market Information* 1 Mile 3 Miles 5 Miles
Population 12,491 101,762 207,590
Households 4,740 41,476 85,267
Median Income $52,967 $49,276 $54,553
*esri - Demographic and Income Profile 2018
Urbandale Ave
Euclid Ave
Euclid Ave
Martin Luther King Jr Pkw
y
Martin Luther K
ing Jr Pkwy
TriangleShopping
Center
16,4
38
VP
D
16,700 VPD
5000 WESTOWN PARKWAY SUITE 400 | WEST DES MOINES, IA 50266-5921 P 515.223.4000 | F 515.222.5220 | KNAPPPROPERTIES.COM
LISTING BROKERKnapp Properties EXCLUSIVELY MARKETED BYBen Garrett 515.401.7071 Brian Erickson, CCIM 515.202.5035
109
RECEPTION100
WAITING101
COPY AREA102 HOTELING
104
STAFF105
OFFICE106
OFFICE107
PANTRY108
TELEHEALTH110
OPEN AREA109
EXAM111
EXAM112
MENS113
ROOM101
CONFERENCE116
STAFF PANTRY115
KIDS ROOM117
CONFERENCE118
STORAGE119
MECHANICAL120
TRAINING121B
STORAGE123
STORAGE122
WOMENS114
100 104A
104B
104C
105
103
106 107
110
111
112
116
119
119A
120
118
117
121A
121B
122
123
TRAINING121A
EXISTING DIMUNKNOWN
121C
121D
114
124
113125
20'-6"
8'-10"
8'-10"
19'-3"
3'-7"
FLUSH
FLUSH
12'-0"
9'-10"9'-10"23'-0"
15'-4"
ALIGN
17'-6"
CLOFMULLION
CLOFMULLION
10'-11"
10'-0"
7'-2"15'-0"
5'-4"
2'-11"
6'-4"
9'-10"
9'-6"
9'-6"
12" MIN
6'-0"
10'-1 3/4"
18'-10 1/4"
2'-1"
CRCR
CRCR
S
SH
S
S
H
S
H
FEX
FEX
1A2.01
A2.015 4
2A2.01
3A2.01
3A2.01
SIM
6A2
.01
11A2.01
DOOR SCHEDULEDoor Number Keyside Rm #
Type Matl/Finish Width HeightDOOR
Type Matl/Finish Opg Width Jamb Type Head TypeFRAME
Fire Rating Hardware Set Remarks Door Number
100
103
104A
104B
104C
105
106
107
109
110
111
112
113
114
116
117
118
119
119A
120
121A
121B
121C
121D
122
123
124
125
RECEPTION
CONFERENCE
HOTELING
HOTELING
HOTELING
STAFF
OFFICE
OFFICE
EXIT
TELEHEALTH
EXAM
EXAM
MENS ROOM
WOMENS ROOM
CONFERENCE
KIDS ROOM
OFFICE
OFFICE
EXIT
OFFICE
TRAINING
TRAINING
TRAINING
TRAINING
STORAGE
STORAGE
SERVICE SINK
ADA CLOSET
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
EXISTING TO REMAIN
WD/STN
EXISTING TO REMAIN
WD/STN
WD/STN
WD/STN
WD/STN
WD/STN
EXISTING TO REMAIN
WD/STN
WD/STN
WD/STN
WD/STN
WD/STN
EXISTING TO REMAIN
WD/STN
WD/STN
EXISTING TO REMAIN
EXISTING TO REMAIN
WD/STN
EXISTING TO REMAIN
EXISTING TO REMAIN
WD/STN
WD/STN
WD/STN
WD/STN
EXISTING
WD/STN
2 @ 3'-0"
3'-0"
2 @ 3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
1'-8"
3'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
7'-0"
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
EXISTING TO REMAIN
HM/PTD
EXISTING TO REMAIN
HM/PTD
HM/PTD
HM/PTD
HM/PTD
HM/PTD
EXISTING TO REMAIN
HM/PTD
HM/PTD
HM/PTD
ALUM.
ALUM.
EXISTING TO REMAIN
HM/PTD
HM/PTD
EXISTING TO REMAIN
EXISTING TO REMAIN
HM/PTD
EXISTING TO REMAIN
EXISTING TO REMAIN
ALUM.
ALUM.
HM/PTD
HM/PTD
HM/PTD
ALUM.
6'-0"
3'-0"
6'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
1'-8"
3'-0"
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
H1
4D
1A
4D
4B
4B
2A
2A
2A
2B
2A
2A
2A
1B
1B
1A
1A
1A
3C
2C
3C
1A
1A
1A
1A
3A
3A
3C
1A
EXISTING DOOR RELOCATED
100
103
104A
104B
104C
105
106
107
109
110
111
112
113
114
116
117
118
119
119A
120
121A
121B
121C
121D
122
123
124
125
CONSTRUCTION LEGEND
NEW INTERIOR PARTITION TO MATCH EXISTING CONSTRUCTION. PARTITION TO EXTEND FROMFLOOR TO UNDERSIDE OF CEILING.
FEXFIRE EXTINGUISHER WALL MTD. W/O CABINET. TO MATCH EXISTING
A2.01
DF
EWC
DRINKING FOUNTAIN
ELECTRIC WATER COOLER
DRAWING NUMBER
100
1
DOOR IDENTIFICATION SYMBOL:
ROOM NUMBER
DOOR NUMBER
DETAIL NUMBER
100
NEW INTERIOR GLASS LITE/SIDELITE. REFER TO INDICATED DETAIL X/A2.__ FOR ADDITIONAL INFO.
1. REFER TO COVER SHEET FOR ADDITIONAL GENERAL NOTES AND REQUIREMENTS.2. CONTRACTOR SHALL BE RESPONSIBLE FOR ADHERING TO ALL FEDERAL, STATE, AND LOCAL CODES, AS WELL AS
SECURING ALL NECESSARY BUILDING PERMITS. CONTRACTOR IS TO BE RESPONSIBLE FOR PLACING ANDINSURING ALL LIFE SAFETY DEVICES MEET ALL APPLICABLE CODES AND ARE IN PROPER WORKING ORDER.DEVICES SHALL INCLUDE BUT NOT BE LIMITED TO: FIRE BELL, PULL STATIONS, SMOKE DETECTION ANDEXTINGUISHERS.
3. REFER TO REFLECTED CEILING PLAN A6.01 FOR ALL EMERGENCY LIGHTING AND EXIT SIGN LOCATIONS.4. REFER TO ELECTRICAL PLAN A5.01 FOR ALL ELECTRICAL EQUIPMENT LOCATIONS.5. CONTRACTOR TO REPAIR OR REPLACE CONVECTORS AS REQUIRED WHERE APPLICABLE, DUE TO PRIOR DAMAGE
AND/OR DAMAGE DURING CONSTRUCTION.6. CONTRACTOR IS TO PROVIDE PLYWOOD BLOCKING AND/OR KITCHEN METAL IN WALL BEYOND
MILLWORK/CABINETRY/SHELVING FOR MOST SECURE METHOD OF ANCHORING AS WELL AS WALL MOUNTEDFURNITURE WITHIN OFFICES AND MEDIA WALLS. SEE PLAN AS REQUIRED FOR LOCATIONS.
7. GC TO INSTALL CONTROL JOINTS IN THE FACE OF GWB PARTITIONS AND CEILINGS WHEN THE SIZE OF THESURFACE EXCEEDS THE FOLLOWING:
PARTITIONS: 30' MAX IN EITHER DIRECTIONCEILINGS: 50' MAX WITH PERIMETER RELIEF, ORCEILINGS: 30' MAX IN EITHER DIRECTION WITHOUT PERIMETER RELIEFIF NOT NOTED ON PLAN, GC TO LOCATE CEILING JOINTS NEAR COLUMN PENETRATIONS TO REDUCE STRESSES INTHE CEILING MEMBRANE.
8. WINDOW BLINDS ARE TO BE REVIEWED FOR DAMAGE AND MISSING BLINDS. ALL NEW/ REPLACEMENT ITEMS ARETO BE PURCHASED BY THE GC.
9. CONTRACTOR IS TO REVIEW EXISTING FIRE HOSE LOCATIONS WHERE APPLICABLE, ALONG CORE AREA TO INSUREDEVICES ARE WORKING AND MEET CODE REQUIREMENTS.
10. ALL M/E/P, SPRINKLER AND LIFESAFETY TO BE DESIGN BUILD. REFER TO DESIGN BUILD CONTRACTOR FORMECHANICAL, ELECTRICAL, PLUMBING, SPRINKLER AND LIFE SAFETY INFORMATION.
CARD READER AT ALL EXIT/ENTRY DOORS TIED TO SECURITY SYSTEM.
COLD WATER LINE LOCATION FOR COFFEE, REFRIGERATOR, ICE MAKER, OR OTHER APPLIANCESW
CR
SPECIALTIES AND FURNISHINGS:1. FIRE EXTINGUISHER CABINETS SHALL BE BUILDING STANDARD, TENTATIVELY LOCATED BY THE CONTRACTOR IN
CONFORMANCE WITH CODE REQUIREMENTS. BEFORE FINAL LOCATION, MEYER DESIGN SHALL RECEIVE ANDAPPROVE LOCATION DRAWINGS. FINAL LOCATION MUST BE APPROVED BY MEYER DESIGN AND THE CONTRACTOR'SENGINEERS RESPONSIBLE FOR ALL LIFE SAFETY WORK.
THERMAL AND MOISTURE PROTECTION:1. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING OR REPLACING ALL INSULATION DAMAGED AS A RESULT OF HIS
WORK.2. THE CONTRACTOR SHALL PROVIDE VINYL VAPOR BARRIER AND SEALANTS AT ALL WALLS SCHEDULED TO RECEIVE
SUCH. ALL MATERIALS AND METHODS OF INSTALLATION SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS.ANY WALL ABUTTING A ROOM TO RECEIVE A SUPPLEMENTAL HVAC SYSTEM IS TO RECEIVE A VAPOR BARRIER ONTHE WARMER SIDE OF THE WALL.
CONCRETE:1. ALL CONCRETE FLOORS MUST BE PROPERLY PREPARED BY GRINDING HIGH SPOTS, FILLING LOW SPOTS OR
FLASH PATCHING TO PROVIDE A SUBSTRATE SUITABLE FOR THE INSTALLATION OF THE NEW FINISH MATERIAL.THIS CONTRACTOR SHALL, UNDER HIS CONTRACT, BE RESPONSIBLE FOR PROVIDING MATERIAL AND LABOR TOLEVEL THE EXISTING CONCRETE FLOOR SURFACE TO WITHIN THE LEVEL TOLERANCE OF 1/8" IN 8'-0"(NON-ACCUMULATIVE). THIS REQUIREMENT IS FOR ALL AREAS WHERE NEW FLOORING MATERIALS ARE SHOWNTO OCCUR.
2. GC TO CONDUCT A MOISTURE PERMEATION TEST ON ALL CONCRETE SLABS ON GRADE AND COMPOSITE FLOORSLABS PRIOR TO THE INSTALLATION OF ANY AND ALL WOOD, VCT, RUBBER TILE, CORK, VINYL OR RUBBERSHEET MATERIALS AS WELL AS EPOXY TERRAZZO AND EPOXY FLOOR COATINGS. TEST IS TO DETERMINE THEAMOUNT OF MOISTURE PASSING UP THRU THE SLAB. PROJECT FLOOR MANUFACTURERS AND MEYER ARE TOBE NOTIFIED OF FINDINGS PRIOR TO THE INSTALLATION OF FINISH FLOORING MATERIALS. ALLMANUFACTURER'S RECOMMENDED INSTALLATION REQUIREMENTS ARE TO BE MET.
MASONRY:1. THE CONTRACTOR IS RESPONSIBLE FOR THE PREPARATION OF ALL EXPOSED BACKUP MASONRY FOR THE
INSTALLATION OF FINISH MATERIALS INDICATED IN THESE DRAWINGS.
MECHANICAL AND PLUMBING:1. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND COORDINATING THE CERTIFIED PROFESSIONAL
ENGINEERING SERVICES FOR THE HVAC, PLUMBING, ELECTRICAL, AND LIFE SAFETY SYSTEMS. THECONTRACTOR SHALL PROVIDE OPERATING MANUALS AND "AS BUILT" DRAWINGS.
2. ALL REFERENCES TO MECHANICAL, ELECTRICAL, PLUMBING, AND LIFE SAFETY ENGINEERING WITHIN THESECONSTRUCTION DOCUMENTS ARE FOR DESIGN INTENT ONLY. THE CONTRACTOR SHALL COMPLY WITH ALLDIMENSIONS DETERMINED BY MEYER DESIGN AND INDICATED ON THESE DRAWINGS WITH RESPECT TOENGINEERING AND SHALL CONTACT MEYER DESIGN IF ANY DIMENSIONAL DISCREPANCIES OCCUR PRIOR TOPROCEEDING WITH THE WORK.
3. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL BE COORDINATED BY THE CONTRACTOR WITH ANYMILLWORK ITEMS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETENESS AND SUITABILITY OF ANY PLUMBING,ELECTRICAL OR MECHANICAL, ARCHITECTURAL, MILLWORK OR HARDWARE ITEM, FIXTURE OR APPLIANCESHOWN ON THE DRAWINGS AND FURNISHED UNDER THIS CONTRACT. A CUT OR SHOP DRAWING (AND SAMPLE,IF SPECIFIED) OF EACH SUCH ITEM, ACCOMPANIED BY A LETTER CERTIFYING THAT THE ITEM IS SUITABLE FORAND WORKABLE ON THIS PROJECT, SHALL BE SUBMITTED TO MEYER DESIGN.
5. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER INTERFACE OF PLUMBING FIXTURES WITH ADJACENTBUILDING COMPONENTS AND/OR EXISTING SYSTEMS AND SHALL NOTIFY MEYER DESIGN IMMEDIATELY OF ANYPOTENTIAL INSTALLATION OR INTERFACE PROBLEM SO THAT ALTERNATE SELECTION OR NEW DESIGN CAN BEMADE.
6. PROVIDE PROPER PIPING FOR HOT AND COLD WATER, DRAIN LINES, VENTS, STACKS AND SHUT-OFF VALVES ASREQUIRED.
EXISTING INTERIOR PARTITION TO REMAIN
DEMOLITION
1A1.01
CONSTRUCTION PLAN1/8" = 1'-0"
GENERAL CONSTRUCTION NOTES
KEY PLANN.T.S.
NOTE: THIS DRAWING WAS BASED UPON PLANS RECEIVED BY OUR OFFICE FROM THE BUILDING OWNER AND HAVE NOT BEENFIELD MEASURED BY MEYER DESIGN, INC. ACTUAL FIELD CONDITIONS MAY VARY.
PM:
DRAWING NO.PROJECTNORTH
SCALE:
JOB. NO.:
A1.01
NUMBER
AS NOTED
PB
DEMO
LITI
ON &
CON
STRU
CTIO
N PL
AN
FLOO
RDO
OR H
ARDW
ARE
SCHE
DULE
AMER
IHEA
LTH
- CAR
ITAS
WEL
LNES
S CE
NTER
HARD
ING
HILL
S34
20 M
ARTI
N LU
THER
KIN
G JR
PAR
KWAY
DES
MOIN
ES, IA
5030
TWP
RE
GIS
TER
ED
AR
CH
ITE
CT
GE
OR
GE
T. W
ILS
ON
, AIA
PA
. RE
G#
RA
0092
35X
PREL
IMIN
AR
Y
NO
T FO
RC
ON
STR
UC
TIO
N
REV. NO. OPERATION DATE BY5/24/16ISSUE FOR REVIEW CHN
mey
erde
sign
inc.
com
227
EA
ST
LAN
CA
STE
R A
VE
NU
E
E-M
AIL
VO
ICE
info
610.
649.
8500
@61
0.64
9.85
09FA
X
© 2
016
ME
YE
R D
ES
IGN
, IN
C. M
EY
ER
AR
CH
ITE
CTS
, IN
C. A
LL R
IGH
TS R
ES
ER
VE
D.
MEY
ER A
RC
HIT
ECTS
, IN
C.
MEY
ER D
ESIG
N, I
NC
.A
RD
MO
RE
, PA
190
03-2
304
TYPE J1/H1: HOLLOW METAL DOOR FRAME1 1/2" = 1'-0"
PARTITION TYPE VARIES
2" PTD. H.M. FRAME TYP.
TYP. @ JAMB & HEADDOUBLE MTL. STUDS
TYPE J2/H2: HOLLOW SIDELIGHT/WINDOW FRAME1 1/2" = 1'-0"
PARTITION TYPE VARIES
2" PTD. H.M. FRAME TYP.
TYP. @ JAMB & HEADDOUBLE MTL. STUDS
TEMPERED SAFETY GLASS
REMOVABLE STOP
FRAME TYPES
WIDTHHEIGHT
1
FRAME TYPES
HARDWARE TYPES
MISCELLANEOUS:
a. HINGESSILENCERSDOOR STOP
b. HINGESSILENCERSDOOR STOPCLOSER
c. HINGESKICK PLATEDOOR STOPCLOSERSILENCERS
d. HINGESDOOR STOPSILENCERSCLOSERAUTO FLUSH BOLTS COORDINATOR
HARDWARE GROUPSLOCKSETS/ LATCHSETS
1. MANUFACTURER: SCHLAGE OR SIMFUNCTION: PASSAGE LATCHSET
2. MANUFACTURER: SCHLAGE OR SIMFUNCTION: ENTRANCE/ OFFICE LOCKSET
3. MANUFACTURER: SCHLAGE OR SIMFUNCTION: STOREROOM LOCKSET
4. MANUFACTURER: VON DUPRIN OR SIMSTYLE: PULLS W/ ELECTRIC PANIC HARDWAREFUNCTION: TIE TO CARD READER WITH REX
DOOR TYPES
DOOR TYPES
"A"
WIDTH
HEIGHT
DOOR/HARDWARE NOTES
1. THERE IS TO BE 6" BETWEEN HINGE SIDE OF DOOR & ADJACENT WALL UNLESS NOTED OTHERWISE.
2. ALL DOORS TO BE 3'-0"W x7'-0" H, INCL. PAIR OF DOUBLE DOORS, SOLID CORE STAINED TO MATCH SAMPLE PROVIDED BYMEYER DESIGN, w/ HOLLOW METAL DOOR FRAMES, UNLESS NOTED OTHERWISE. SUBMIT SAMPLE TO MEYER DESIGNFOR APPROVAL PRIOR TO USE.
3. ALL HOLLOW METAL DOOR FRAMES SHALL BE KNOCK-DOWN CONSTRUCTION.
4. SWING DOORS SHALL BE 1-3/4" THICK SOLID CORE WOOD, EXCEPT CLOSET DOORS WHICH SHOULD BE 1-3/4" HOLLOWCORE WOOD. MATCH OR RE-USE BUILDING STANDARD WHERE APPLICABLE..
5. CONTRACTOR SHALL ENSURE, UNLESS SPECIFICALLY NOTED OTHERWISE, THAT ALL DOORS OPENING OVER CARPETSHALL SWING CLEARLY OVER CARPET.
6. PROVIDE COAT HOOKS ON ALL OFFICE DOORS, UNLESS NOTED OTHERWISE. COAT HOOKS TO BE ROCKWOOD, MODEL #806, 1 1/16"W X 1 1/4"H, OR SIM. INSTALL 66" AFF. SEE DOOR HARDWARE SCHEDULE FOR SPECIFIC ROOM NUMBERLOCATIONS.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ORDERING AND INSTALLING APPROPRIATE HARDWARE.
8. ALL NEW HARDWARE FINISH TO MATCH EXISTING CONDITIONS.
9. ALL HINGES TO BE 5 KNUCKLE BUTT-HINGE (TYP.) UNLESS NOTED OTHERWISE.
10. CONTRACTOR TO PROVIDE WALL OR FLOOR STOPS AS REQUIRED IN ROOMS INDICATING DOOR STOPS. CONTRACTORIS TO FIELD INVENTORY CONDITIONS TO DETERMINE ACTUAL COUNT AND TYPE REQUIRED.
11. CONTRACTOR TO REFER TO TENANT SPECIFIED MFR. OPTIONS AND SELECT BEST OPTION AND HARDWARE STYLEBASED UPON PRICING AND AVAILABILITY.
ACCEPTABLE PRODUCTS:
DOOR BUTTS: HAGER, LAWRENCE OR MCKINNEYLEVER-OPERATED LOCKSETS: SCHLAGE OR YALELEVER-OPERATED LATCHSETS: SCHLAGE OR YALEDOOR CLOSERS: CORBIN-RUSSWIN, HAGER, LCN, RIXSON OR YALEPANIC DEVICES: ADAMS RITE, CORBIN-RUSSWIN, HAGER, VON DUPRIN OR YALEDOOR STOPS: IVES, MCKINNEY, RIXSON OR EQUALFLUSH BOLTS: IVES, MCKINNEY OR EQUALKICK PLATES: IVES, MCKINNEY OR EQUALHINGES: HAGER, IVES, MCKINNEY OR EQUALSILENCERS: IVES, MCKINNEY OR EQUALROLLER CATCH: GLYNN JOHNSON OR IVESPIVOTS: IVES, MCKINNEY OR RIXSON
12. ALL INTERIOR DOOR KEYING ASSIGNMENTS ARE TO BE COORDINATED WITH TENANT. ALL LOCKSETS SHALL BE KEYEDTO THE BUILDING'S MASTER KEY SYSTEMS AND THE CONTRACTOR SHALL SCHEDULE A FINAL MEETING WITH THEOWNER TO TURN OVER THE KEYS AFTER ALL CONSTRUCTION LOCKSETS HAVE BEEN REMOVED.
13. COORDINATE WITH TENANT'S SECURITY VENDOR TO PROVIDE APPROPRIATE HARDWARE FOR ALL SECURITY DOORS.CONTRACTOR TO PROVIDE ALL NECESSARY CONDUIT/WIRE CHASE TO ALLOW FOR ELECTRICAL CONNECTION AT THESELOCATIONS. MAGNETIC LOCK @ ALL CARD READERS BY SECURITY. DOOR PREP BY G.C. NO ELECTRICAL HINGES. G.C. ISTO MORTISE OUT AREA IN DOOR FOR PLATE.
14. REPLACE ALL CORE DOOR HARDWARE TO MEET ADA AS REQ'D. AS WELL AS NEW TENANT FINISH.
15. GC TO PROVIDE HOLLOW METAL DOOR FRAMES AS REQ'D. TO ACCOMMODATE INCREASED WALL THICKNESS ASAPPROPRIATE, UNLESS NOTED OTHERWISE.
16. ALL FIRE-RATED DOORS SHALL BE APPROPRIATELY LABELED AND HAVE THE PROPER CODE-COMPLIANT HARDWARE.
17. NON-CODE GLASS SHALL BE CLEAR FLOAT GLASS, THICKNESS AS APPROPRIATE PER INSTALLATION.
2A1.01
DEMOLITION PLAN1/16" = 1'-0"
NEW FIRE HORN AND STROBE
FIRE EXTINGUISHER WALL MTD. W/O CABINET.FEX
H
NEW STROBES
NEW FULL HEIGHT INTERIOR WALL SYSTEM TO EXTEND FROM FLOOR TO STRUCTURAL DECKABOVE: 2-1/2" METAL STUDS W/ 5/8" GWB. PROVIDE SOUND ATTENUATION BLANKET.
I:\D
RA
WIN
GS
\Am
erih
ealth
Mer
cy\A
mer
ihea
lth -
Car
itas\
Des
Moi
nes\
Des
Moi
nes.
A10
1.dw
g, 5
/24/
2016
4:4
7:36
PM
, cni
emey
er
HARDING HILLSSHOPPING CENTER3420-3452 MLK PKWY SUITE 100,DES MOINES, IA