Date post: | 04-May-2018 |
Category: |
Documents |
Upload: | trannguyet |
View: | 225 times |
Download: | 1 times |
Data Sheet
HBX-1 Halmi-Briggs
Venturi Flow MeterLow Reynolds Number, Wide-RangeFlow Metering
HBX-1 Halmi-Briggs Features
AAccccuurraaccyy: +/- 0.25% laboratory flow calibrated accuracy
RReeppeeaattaabbiilliittyy: +/- 0.25%
LLiinneeaarriittyy: coefficient of discharge from Reynolds Numbers as low as 6,000 and beyond
BBeettaa rraattiiooss: from 0.25 to 0.80
SSeerrvviiccee ccaappaabbiilliittyy: process line fluids, clear liquids, solids-bearing liquids, wet or dry gas, steam, abrasive, or harsh liquids and gases
MMaatteerriiaallss:Virtually any machinable or weldable material, including carbon steel, stainless alloys, Hastelloy®, or others upon request
Plasma spray treatment availablefor additional hardness in abrasive flow applications
EEnndd ccoonnffiigguurraattiioonn: plain, flanged (HBX-1 - FVFLF), RTJ, wafer, mechanical, threaded (HBX-1 -FVTLF), butt weld ends (HBX-1 - FVWLF)
LLiinnee ssiizzeess: 3/8” through 24” optimal (other sizes available)
PPiippiinngg rreeqquuiirreemmeennttss: Downstream straight: not required
Upstream straight: minimal dependent upon flow disturbers; no black box or signal conditioning required
PPrreessssuurree lloossss: modest between HVT-Halmi Venturi and OrificePlates
Primary Flow Signal, Inc. is a leader in the design and manufacture of Venturi differential flow meters. Field-proven in
hundreds of thousands of installations worldwide, differential metering ensures the most accurate and reliable metering available anywhere. Through innovation in design and manufacturing, coupled with peerless engineering and technical expertise, PFS delivers customers versatile, ultra-long lasting liquid and gas metering solutions for a variety of applications and industries.
The HBX-1 Halmi-Briggs Venturi primary flow element delivers metering accuracy, performance, and reliability over a wide flow range for a broad array of application requirements.
With repeatable +/- 0.25% lab calibrated accuracy and a stable linear coefficient of discharge, the HBX-1 Halmi-Briggs Venturi exceeds competing products.This design is ideal for full pipe flow of gas, liquid, and steam for applications, such as water, wastewater,oil and gas, industrial, commercial, and others. Coupledwith our state-of-the-art secondary instrumentation,PFS’s differential metering delivers industry-leading reliability and accuracy. It can also cut costs by mitigating requirements for linearization software, computers, or other secondary signal conditioning.
All PFS products are proudly made in the U.S.A.
Secondary Instrumentation
Standard secondary instrumentation systems are available, such as a DP Transmitter with integral indicator/totalizer in Class 1 Div. 1 enclosure. Special instrumentation packages that provide metering system performance to meet any requirement, as well as custom meters and instrumentation options for unique applications.
Support Services
In addition to a wide range of differential producing Venturi flow meters, orifice plates, WedgeType™ flow meters, and open channel flow elements, Primary FlowSignal provides comprehensive, specialized services fornew and existing flow meters, including rehabilitation, hydraulic analysis, and full engineering support.
Certifications
ISO 9001; ASME S, U, R; European PED Module H; and other internationally recognized certifications, such as GOST, IBR, and CRN.
Contact a Field Application Engineer for assistance.
HBX-1 Performance Chart
Data Sheet
HBX-1 Halmi-Briggs
10,000
1.0075
DISC
HARG
E CO
EFFI
CIEN
T FA
CTOR
C
PIPE REYNOLDS NUMBER
1.0050
1.0025
1.0000
0.9975
0.9950
0.992520,000 30,000 40,000 50,000 60,000 70,000
Source: Alden Research Laboratory, Holden, MA; Utah Water Research Laboratory
80,000 90,000 100,000
+/-0.25% Laboratory Flow Calibrated Accuracy Band
HBX-1 has a constant discharge coefficient with a +/- 0.25% accuracy, basedon laboratory flow calibrationof the meter, to a pipeReynolds Number as low as 6,000.
Primary Flow Signal, Inc. products and operations are certified to industry standards for safety and performance. Visit our web site for details.
Copyright © 2013-2016 Primary Flow Signal, Inc. - All rights reserved. Information contained herein is subject to change at any time without prior notice.
PFS HBX1 DS 2013 Rev 2
Headquarters800 Wellington Avenue | Cranston, RI 02910 USATel: +1-401-461-6366 | Toll Free: +1-877-737-3569Fax: +1-401-461-4450