Find us at www.keysight.com Page 1 HDMI2.1 Sink Test Procedure Test ID: HF2-4 Using Keysight E5080B ENA with Enhanced TDR App
Transcript

P

a

g

e

Find us at www.keysight.com Page 1

HDMI2.1 Sink Test Procedure Test ID: HF2-4 Using Keysight E5080B ENA with

Enhanced TDR App

P

a

g

e

Find us at www.keysight.com Page 2

Table of Contents

1.Revision History.................................................................................................................................... 3

2.Introduction........................................................................................................................................... 3

3.Required Equipment ............................................................................................................................. 3

4.Test Flow Chart .................................................................................................................................... 4

5.Instrument Setup .................................................................................................................................. 5

5.1 Recalling a State File ............................................................................................................ 5

5.2 Saving a State File ................................................................................................................ 6

5.3 Calibration ............................................................................................................................. 6

5.3.1 ECal Calibration & Fixture Compensation............................................................... 6

5.3.2 DUT Length Measurement ..................................................................................... 8

5.3.3 Adjustment of Effective Rise Time .......................................................................... 9

6.Measurement and Data Analysis ........................................................................................................ 11

6.1 Differential Impedance......................................................................................................... 11

6.2 Differential Return Loss (Informative)................................................................................... 13

7.[Appendix] Manual Setup .................................................................................................................... 14

7.1 Launch TDR Class .............................................................................................................. 14

7.2 Channel & Trace Setup ....................................................................................................... 14

7.3 Differential Impedance ......................................................................................................... 15

7.4 Differential Return Loss ....................................................................................................... 15

Web Resources ..................................................................................................................................... 16

P

a

g

e

Find us at www.keysight.com Page 3

1. Revision History

Revision Comments Date

1.0 Initial revision 3-Sep-2020

2. Introduction

This document provides testing procedures for HDMI CTS 2.1 Test ID HF 2-4: “Sink TMDS Electrical - 6G

- Differential Impedance.” HDMI Forum created HDMI CTS 2.1 to specify a set of tests that should be

performed to verify features described in HDMI Specification Version 2.1. The Method of Implementation

for the test using the Keysight E5071C ENA is available on HDMI Form web site at

http://www.hdmiforum.org/.

This document complements the test procedure using the E5080B ENA (Successor of E5071C).

3. Required Equipment

Description Test Equipment Qty

Network Analyzer Keysight E5080B ENA Series Network Analyzer:

• Option 2x0/4x0/4x2 (Select one test set option

of 9, 14 or 20 GHz)

1 ea.

Software S96011A/B Enhanced time-domain analysis with TDR 1 ea.

ECal Module Keysight ECal module with 3.5-mm connectors.

• N4691D (2-port, 26.5 GHz), N4431D (4-port,

13.5 GHz) or N4433D (4-port, 26.5 GHz)

1 ea.

Adapter 3.5 mm (f) to Type-N (m) (ex. Keysight 1250-1744)

for E5080B with type-N connectors or 83059B coaxial

adapter for E5080B with 3.5-mm connectors.

2 ea.

RF cable 3.5 mm or SMA cables of 9 GHz bandwidth or more. 2 ea.

50 ohm

terminator

To terminate unused differential pairs (ex. Keysight

909D-301)

6 ea.

Sink TPA-P BitifEye BIT-1010-0201-0 HDMI 2.0 Type A

Sink Test Adapter Kit or

BIT-1010-0225-1, HDMI 2.0 Type A with HEAC Plug

Test Point Adapter, with 12 inch SMA cables or

BIT-1010-0240-1, HDMI 2.0 Type A with HEAC Plug

Test Point Adapter, with 6 inch SMA cables

1 ea.

Power

Supply

(To provide +5 V between +5 V power and

DDC/CEC Ground)

1 ea.

P

a

g

e

Find us at www.keysight.com Page 4

4. Test Flow Chart

Note: Hard Keys (Keys on the E5080B’s front panel), Soft keys (Keys on the E5080B’s screen), Buttons

of the TDR software, and Tabs of the TDR software are displayed in Bold.

1Set measurement conditions by recalling a state file.

2Connect matched 3.5 mm cables to the test ports of the instrument.

3

Perform Calibraiton

- Full Calibration (ECal) and Fixture Compensation

- DUT Length Measurement

- Adjustment of Effective Rise Time

4

Perform Measurements

- Differential Impedance

- Differential Return Loss

P

a

g

e

Find us at www.keysight.com Page 5

5. Instrument Setup

5.1 Recalling a State File

This section describes how to recall a state file of the E5080B that includes all the measurement settings

for HDMI impedance test. The state file can be downloaded at:

www.keysight.com/find/ena-tdr_compliance

Copy the state file into the E5080B’s directory via USB mass storage device and recall the state file with

the TDR measurement class of S96011A/B software (*.tdr). Necessary parameters for testing are

automatically set up in the E5080B. Refer to Appendix for the details about manual setup.

1. Press Setup hardkey (or click Setup soft key) 2. Click Meas Class… to show the dialog for selecting a measurement class. 3. Check TDR. 4. Click OK. 5. Click OK to launch TDR in basic mode.

If TDR setup wizard is shown, click Close button in the TDR setup wizard main windows.

6. Open Setup tab of the TDR software. 7. Click File and select Recall State to open the Recall State dialog box.

8. Specify a folder and a file name (*.tdr) and click Open.

P

a

g

e

Find us at www.keysight.com Page 6

5.2 Saving a State File

All the measurement settings including calibration information can be saved in a state file (*.tdr). After

performing calibration, all necessary calibration coefficients are saved in a state file and can be recalled

for the next measurements.

1. Open Setup tab of the TDR software. 2. Click File and select Save State to open the Save State dialog box. 3. Enter file name and save the state file.

5.3 Calibration

The purpose of this step is to calibrate the delay and loss of the RF cables (and test fixtures) by following

the wizard of E5080B. Full calibration is performed by using the 2- or 4-port ECal Module at the end of RF

cables connected to the ENA test ports. After connecting the test fixture to the cables, the effect of the

fixture is removed by the fixture compensation function of the TDR software.

5.3.1 ECal Calibration & Fixture Compensation

Full calibration is performed by the TDR measurement class with E5080B. 2- or 4-port ECal Module (i.e. N4433D) connected to the E5080B is necessary for the calibration procedure.

1. Open Setup tab of the TDR software. 2. Click ECal to launch the Full Calibration (ECal) and Fixture Compensation Wizard.

3. Perform Full Calibration (ECal) a. Connect E5080B Port 1 & 2 to the ECal Module with the test cables b. Click Calibrate to launch calibration wizard

P

a

g

e

Find us at www.keysight.com Page 7

c. Select 2 Port ECal (or 4 Port ECal) to perform full 2-port calibration. d. Select “Port 1” as 1st port and “Port 2” as 2nd port. e. Click Next>

f. Follow instructions of calibration wizard until the calibration is complete.

4. Perform Fixture Compensation a. Disconnect the cables from the ECal module. b. Connect the cables to the test fixture. Do not connect DUT. c. Click Fixture Comp to perform fixture compensation. d. Once green check mark appears, click Finish.

P

a

g

e

Find us at www.keysight.com Page 8

5.3.2 DUT Length Measurement

Full calibration is performed by the TDR measurement class with E5080B. The 4-port ECal Module (i.e. N4433D) connected to the E5080B is necessary for the calibration procedure.

1. Open Setup tab of the TDR software. 2. Click DUT Length - Auto to launch the DUT Length Wizard.

3. Perform DUT Length Measurement a. Connect the test fixture to the DUT. Do not power on the DUT. b. Click Measure to specify DUT’s electrical length. c. Once green check mark appears, click Finish.

P

a

g

e

Find us at www.keysight.com Page 9

5.3.3 Adjustment of Effective Rise Time

The effective rise time at the open end of the HDMI connector of the test fixture is adjusted for differential impedance measurements. DUT is disconnected during the adjustment procedure. 1. Open TDR/TDT tab. 2. Click Trace 1 (Tdd11) for Differential Impedance. 3. Click Parameter tab. 4. Select “Time Domain” and “Differential” for Measure. 5. Select Format to “Volt”. 6. Click Marker Search and select “Rise Time (10 – 90%)”. 7. Press Run to measure the rise time on the screen. 8. Set Horizontal scale to 500 ps/div and reference position to -750 ps.

9. Enter rise time until the measured rise time on trace 1 (Tdd11) is close to the specified value of 200 ps, but not exceed 200 ps.

P

a

g

e

Find us at www.keysight.com Page 10

10. Click Marker Search and select “Rise Time (10 – 90%)” to turn off the marker. 11. Select Format to “Impedance”.

P

a

g

e

Find us at www.keysight.com Page 11

6. Measurement and Data Analysis

6.1 Differential Impedance

This section describes how to recall a state file of the E5080B that includes all the measurement settings

for HDMI impedance test. The state

1. Drive +5 V between +5 V power and DDC/CEC Ground. 2. Turn on the sink DUT. 3. Connect the test fixture to the Sink DUT HDMI output connector (Figure 1).

Figure 1. Differential Impedance for Sink DUT - Test Setup

Note: Unused TMDS differential lanes of the test fixture should be connected to 50 ohm terminators.

4. Select Trace 1. 5. Press Stop Single.

6. Press Auto scale and select “X” of X-axis. 7. Turn on the marker 1 to measure the impedance at the DUT Sink Termination (ZDIFF_TERM) where the

impedance stabilizes.

P

a

g

e

Find us at www.keysight.com Page 12

Figure 2. Sink Differential Impedance Example

If (ZDIFF_TERM < 90 ohm) OR (ZDIFF_TERM > 110 ohm), then FAIL.

8. Measure the impedance value (ZDIFF_THROUGH) along the signal path from DUT HDMI input connector until just before the termination impedance. a. Open Setup tab. b. Under More Functions tab, click Advanced Mode >> and then click Yes.

c. Press Marker to turn on marker 1. d. Set marker range between DUT HDMI input connector and DUT Sink Termination.

➢ Press Search > Main > Domain and select User 1 for marker search range

P

a

g

e

Find us at www.keysight.com Page 13

➢ Press Search > Main > Domain Start and set start point of X-axis in time (ex. yy nsec) at DUT

HDMI input connector. ➢ Press Search > Main > Domain Stop and set stop point of X-axis in time (ex. zz nsec) at DUT Sink

Termination. e. Search the maximum and minimum impedance values (ZDIFF_HIGH and ZDIFF_LOW) in the measurement

area. Record these values in time (ex. xx nsec.) ➢ Press Search > Main > Max Search to find ZDIFF_HIGH. ➢ Press Search > Main > Min Search to find ZDIFF_LOW.

f. Verify the measured impedance values (ZDIFF_HIGH and ZDIFF_LOW) are within the limit in Table 2. Table 2. Sink Differential Impedance Limit

Min Max Note

Thru impedance 75 ohm 125 ohm

85 ohm 115 ohm (*1)

1. If the duration of violation is 250 ps or larger, or there is more than one exclusion, then FAIL.

6.2 Differential Return Loss (Informative)

Differential return loss in frequency-domain of the DUT sink can be monitored with the same setup of the

differential impedance measurement. The measured result is displayed on trace 2.

1. Connect DUT (Figure 1). 2. Select Trace 2 (Sdd11).

3. Press Stop Single.

P

a

g

e

Find us at www.keysight.com Page 14

7. [Appendix] Manual Setup The procedure of manual setup for impedance (time-domain) and return loss (frequency-domain)

measurements are introduced in the section. All the following parameters are saved in the E5080B’s state

file.

7.1 Launch TDR Class

1. Press Setup hardkey (or click soft key) 2. Click Meas Class… to show the dialog of selecting a measurement class with E5080B. 3. Check TDR. 4. Click OK. 5. Click OK to launch TDR in basic mode.

7.2 Channel & Trace Setup

If TDR setup wizard is shown when launching the TDR software, click Close button in the TDR setup wizard main window. 1. Click Setup tab in the TDR software. 2. Click Preset to preset the instrument. Click OK in a dialog box to continue. 3. Set DUT Topology to “Differential 1-port”. Click OK in a dialog box. 4. Set Source Power to “-20 dBm”.

5. Click Average tab. 6. Set IF Bandwidth to “10 kHz”.

P

a

g

e

Find us at www.keysight.com Page 15

7. Click Stop Single.

8. Open TDR/TDT tab. 9. Click Trace Control tab.

10. Clear Time and Marker check box under Coupling.

7.3 Differential Impedance

1. Click Trace 1 (Tdd11). 2. Open TDR/TDT tab. 3. Open Parameters tab. 4. Select “Time Domain” and “Differential” for Measure. 5. Select Format to “Impedance”. 6. Select “10-90%” and set “200 ps” for Rise Time. 7. Click Tdd11. 8. Click the box below the left knob under Vertical. Set the vertical scale to “10 Ohm/div” in a dialog box. 9. Click the box below the right knob under Vertical. Set the vertical center to “50 Ohm” in a dialog box.

7.4 Differential Return Loss

1. Click Trace 2 (Sdd11). 2. Open TDR/TDT tab. 3. Open Parameters tab. 4. Select “S-Parameter” and “Differential” for Measure. 5. Select Format to “Log Mag” 6. Click Sdd11. 7. Click the box below the left knob under Vertical. Set the vertical scale to “10 dB/div” in a dialog box. 8. Click the box below the right knob under Vertical. Set the vertical center to “0 dB” in a dialog box.

P

a

g

e

Find us at www.keysight.com Page 16

Learn more at: www.keysight.com

For more information on Keysight Technologies’ products, applications or services,

please contact your local Keysight office. The complete list is available at:

www.keysight.com/find/contactus

This information is subject to change without notice. © Keysight Technologies, 2020, Published in USA, September 7, 2020, 3120-1469.EN