+ All Categories
Home > Documents > Heavy-Duty Pneumatic Actuator IS & IC Series

Heavy-Duty Pneumatic Actuator IS & IC Series

Date post: 16-Oct-2021
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
14
Heavy-Duty Pneumatic Actuator IS & IC Series BS EN ISO 9001:2000 ®
Transcript
Page 1: Heavy-Duty Pneumatic Actuator IS & IC Series

Heavy-Duty Pneumatic Actuator IS & IC Series

BS EN ISO 9001:2000

®

Page 2: Heavy-Duty Pneumatic Actuator IS & IC Series

2

INTRODUCTIONINTRODUCTION

Heavy-Duty Pneumatic ActuatorIS & IC Series

Heavy-Duty Pneumatic Actuator

- The IS & IC series of Heavy Duty scotch yoke actuators are designed to suit a wide range of valves and damper applications and offer a wide range of torques to enable operation of ball, butterfly, plug valves and dampers or any device that requires a quarter turn operation for on-off or modulating service.

- IS series has a symmetrical design yoke that produces maximum torque at both ends of the 90° cycle.

- IC series has a canted design yoke that produces maximum torque at either the close or open end.

- Both series of actuators have a complete range of options & accessories for control and monitoring, including Manual Handwheel (Jackscrew), Hydraulic Overrides, Declutch Gearboxes, Limit switches, Solenoid Valves, Positioners and other control accessories.

- The modular design and construction provides maximum convenience during installation, maintenance and storage.

Page 3: Heavy-Duty Pneumatic Actuator IS & IC Series

MODULAR CONSTRUCTIONMODULAR CONSTRUCTION

3

FEATUREFEATURE

IS & IC Series

Standard IS & IC series actuator are provided with below features.• Two years standard warranty.• IP66 for water ingress protection and corrosion resistance.• Interchangeable modular construction - an advantage for inventory, service, maintenance• Standard operating pressure: 40 to 100 PSIG (2.8 to 7 Bar)• Standard operating temperature: -20oC to +80oC with high and low temperature optional trims available.• Mounting dimension is to meet with ISO5211

Optional • Different temperature range : -30oC to 100oC• Different pressure range: Max. 10 Bar• Manual operation : Hydraulic or Handwheel (jackscrew), Declutchable gear box• Different mounting dimension: (MSS-SP101 or others on request)

Center Body

Manual Handwheel

Pneumatic Cylinder

Spring Catridge

Hydraulic Cylinder& Pump

Symmetric Yoke Canted Yoke Hydraulic Cylinder& Pump

Manual Handwheel

Pneumatic Cylinder

Spring Catridge

Provides maximum operational flexibility in selection of Pneumatic cylinder, Body and Spring Pack depending on project requirement.Additional benefit in less cost for maintenance and reduced spare parts inventory.

Page 4: Heavy-Duty Pneumatic Actuator IS & IC Series

CONSTRUCTIONCONSTRUCTION

4

Guide Bar for Safety IncreasedTwo piston guide bars provided (Up & Down) preventing piston sag due to abrasion after long life cycle. Engineered plastic bush with long life durability and low abrasion characteristics enables smooth operation at low pressure.

Piston Guide RingHigh quality Back-up Ring to

prevent any possible leakage and ensure long lifespan.

Replaceable BearingSurface heat-treated Slide Pin, Slide Bearing, and Yoke Slide provides semi-permanent lifespan with strong durability of abrasion.

Travel Stop / Adjustment And IndicatorTravel stop/adjustment can be set in the range of -5° ~ +95° of stroke ( ± 5°) The travel stops are designed in the vertical position in order to bear great shock.Indicator with pointer and angle meter for easy determination of actuator position.

Spring Rod GuideHard anodized Aluminum casting and external epoxy powder coated against severe industrial environment.

Standard NAMUR Mounting Dimension

For easy installation of accessories like limit switch

box, positioners etc.

AdaptionIn order for direct mounting valve and actuator without separate coupler and

bracket, bore diameter for valve shaft is increased, so that it can accept thicker

diameter shaft rather than standard.Mounting flange as per ISO5211

Heavy-Duty Pneumatic Actuator

Page 5: Heavy-Duty Pneumatic Actuator IS & IC Series

5

MATERIALSMATERIALS

IS & IC Series

27

26 25

24 23 22 21 20 197 8

9 10

1112

1314

15

37

38 39 4036

4142

45

4443

6

54321

34

33

16

3231

30 2928

35

1817

DESCRIPTIONBODYLOWER BUSHINGO-RINGUPPER BUSHINGSTOPPER BOLTSTOPPER NUTCENTER BODY COVERCENTER BODY COVER BOLTPOINTERYOKESNAP RINGSLIDE PINSLIDE ROLLERSLIDE BLOCKFRONT COVER BOLTCYLINDERCOVER FIXING PINPOSITION INDICATORCYLINDER FRONT COVERCOVER O-RINGPISTON RODPISTONPISTION GUIDE BAR

MATERIALA395B139NBR B139CARBON STEELCARBON STEELA283CARBON STEELA240CARBON STEELCARBON STEELCARBON STEELCARBON STEELCARBON STEELCARBON STEELA53CARBON STEELCARBON STEELCARBON STEELNBRCARBON STEELCARBON STEELCARBON STEEL

NO123456789

1011121314151617181920212223

DESCRIPTIONTIE BOLTCYLINDER END COVERLIFTING LUGTIE BOLT NUTFRONT COVER BUSHINGO-RINGBACK-UP RINGPISTON O-RINGPISTON GUIDE BUSHINGPISTON GUIDE BUSHING O-RINGPISTON LOCK BOLTPISTON GUIDE BAR NUTSPRING CASESPRING CASE FRONT COVERSPRING ROD GUIDE BUSHINGSPRING RODSPRINGSPRING RETAINERSPRING CASE END COVERSPRING ROD LOCK NUTCOVERCOVER BOLT

MATERIALCARBON STEELCARBON STEELCARBON STEELCARBON STEELENGINEERING PLASTICNBRPTFENBRENGINEERING PLASTICNBRCARBON STEELCARBON STEELA120CARBON STEELENGINEERING PLASTICCARBON STEELCARBON STEELCARBON STEELCARBON STEELCARBON STEELCARBON STEELCARBON STEEL

NO24252627282930313233343536373839404142434445

Page 6: Heavy-Duty Pneumatic Actuator IS & IC Series

SYMMETRIC TECHNICAL DATASYMMETRIC TECHNICAL DATA

6 Heavy-Duty Pneumatic Actuator

MODEL

ISD 02-20

ISD 02-25

ISD 02-30

ISD 02-35

ISD 03-35

ISD 03-38

ISD 03-43

ISD 04-43

ISD 04-48

ISD 04-53

ISD 05-53

ISD 05-58

ISD 05-63

ISD 06-63

ISD 06-68

ISD 06-73

Start

1,418

2,215

3,190

3,978

4,680

6,181

7,891

10,258

12,752

15,517

19,098

22,834

26,905

33,631

39,135

45,057

End

1,413

2,207

3,178

3,963

4,663

6,159

7,862

10,221

12,705

15,460

19,028

22,750

26,805

33,507

38,991

44,891

Run

724

1,132

1,630

2,032

2,391

3,158

4,032

5,241

6,515

7,928

9,757

11,666

13,746

17,182

19,994

23,020

2.8 Bar

Start

2,785

4,352

6,267

7,814

9,193

12,142

15,500

20,151

25,049

30,480

37,514

44,853

52,848

66,060

76,873

88,505

End

2,775

4,336

6,243

7,785

9,159

12,097

15,443

20,076

24,957

30,368

37,376

44,688

52,654

65,817

76,590

88,179

Run

1,423

2,223

3,202

3,992

4,697

6,203

7,919

10,295

12,798

15,572

19,166

22,916

27,000

33,750

39,275

45,218

5.5 Bar

Start

3,545

5,539

7,976

9,945

11,700

15,453

19,728

25,646

31,881

38,793

47,745

57,086

67,262

84,077

97,839

112,643

End

3,532

5,518

7,946

9,908

11,657

15,396

19,655

25,552

31,763

38,650

47,569

56,876

67,014

83,767

97,478

112,228

Run

1,811

2,830

4,075

5,081

5,978

7,895

10,079

13,103

16,288

19,819

24,393

29,166

34,364

42,955

49,986

57,550

7 Bar

Start

2,127

3,323

4,785

5,967

7,020

9,272

11,837

15,388

19,128

23,276

28,647

34,252

40,357

50,446

58,703

67,586

End

2,119

3,311

4,768

5,945

6,994

9,238

11,793

15,331

19,058

23,190

28,541

34,125

40,208

50,260

58,487

67,337

Run

1,087

1,698

2,445

3,049

3,587

4,737

6,047

7,862

9,773

11,892

14,636

17,499

20,618

25,773

29,992

34,530

4.2 Bar

Double Acting Unit : Nm

Symmetric Yoke

Torque Curve Air TorqueSpring Torque

Double Acting Actuator

TOR

QU

E

TOR

QU

E

0o

Closed0o

Closed90o

Open45o

POSITION45o

POSITION90o

Open

Spring Return Actuator

SymmetricalSymmetrical

Page 7: Heavy-Duty Pneumatic Actuator IS & IC Series

7IS & IC Series

SYMMETRIC TECHNICAL DATASYMMETRIC TECHNICAL DATA

Start1,0221,4431,8251,4431,8252,1802,7102,1802,7103,4223,8013,4223,8014,5144,3885,0895,5795,0895,5796,5697,2127,9828,8748,847

10,17111,20010,17111,20012,14113,13014,89215,51115,70117,57019,62717,57019,62722,01825,28727,11029,31730,30235,11137,49535,11137,49542,48345,30046,12850,288

Run479677856677856

1,0221,2711,0221,2711,6051,7821,6051,7822,1172,0062,3272,5512,3272,5513,0043,2983,6504,0583,9944,5915,0564,5915,0565,4805,9276,7227,0027,3128,1839,1418,1839,141

10,25411,77712,62613,65413,62315,78416,85615,78416,85619,09820,36520,73722,607

End700989

1,251989

1,2511,4951,8581,4951,8582,3462,6052,3462,6053,0942,8073,2553,5693,2553,5694,2034,6145,1065,6775,4586,2746,9096,2746,9097,4908,1009,1879,569

10,56611,82413,20811,82413,20814,81717,01718,24419,73018,47321,40522,85821,40522,85825,89927,61628,12130,657

Start696

1,189935

1,6451,293

1,583

1,817

2,8382,534

3,179

4,6573,865

6,2845,668

7,1956,141

8,276

10,6809,338

9,591

14,703

17,199

Run216

401243

535316

376

339

731534

646

1,098572

1,6931,284

1,7611,061

2,151

3,0652,223

1,733

3,132

3,705

End321

627313

818384

444

226

877476

533

1,12641

2,0781,234

1,910466

2,728

4,2482,561

1,245

2,628

3,182

Start

2,4792,225

3,9233,571

5,4615,209

6,645

8,1917,887

10,913

14,18313,629

18,79118,175

23,659

28,71828,348

34,84333,501

42,56241,001

47,54746,106

60,79259,383

72,73169,782

81,98679,527

Run

998841

1,5901,372

2,1742,018

2,609

3,2133,016

4,304

5,6585,299

7,4907,081

9,511

11,52511,279

14,26513,422

17,62216,642

19,13018,225

23,91022,967

29,15427,181

32,39530,749

End

1,7131,399

2,7372,303

3,7103,399

4,423

5,3864,984

7,238

9,5728,840

12,61211,768

16,090

19,48118,974

24,59922,913

30,54428,583

32,72130,911

39,89837,943

49,18645,096

54,20250,791

Start1,3841,103849

2,2642,0101,774

3,1922,8402,3662,1153,5133,2612,7874,0873,6523,3485,8365,5324,9177,0066,5285,9759,6328,8408,224

12,46911,85311,29014,72113,66613,29617,53816,31814,97621,75520,41218,85122,63921,45020,00931,01428,17026,76136,18034,77031,82038,77038,28135,821

Run535361203899741594

1,2521,033739583

1,2711,115820

1,3911,109911

2,1211,9241,5252,4202,1101,7513,4042,8782,4694,5604,1513,7775,2494,5494,3036,4455,6794,8368,1987,3566,3767,7817,0346,12910,6938,7907,84712,50211,5599,58612,46512,13810,492

End900554241

1,5321,218927

2,1221,6871,103793

2,0691,7581,1732,1371,5621,1613,4023,0002,1883,7573,1252,3935,3174,2313,3877,2876,4435,6728,2496,8046,297

10,5298,9967,310

13,57511,8899,928

12,23510,7418,930

16,36612,42210,46819,16817,21313,12318,07017,39113,980

Start2,0221,7421,4883,2623,0082,7722,4194,6294,2773,8033,5525,3045,0534,5786,1945,7595,4558,6208,3167,701

10,56010,0829,529

14,25213,46012,84418,21217,59617,03321,70920,65520,28426,13924,91923,57732,03830,69629,13534,75633,56632,12546,16043,31641,90753,80552,39549,44559,06258,57356,113

Run831657499

1,3611,2031,057838

1,9181,6991,4051,2492,1011,9451,6502,3682,0851,8883,4113,2142,8164,0673,7573,3985,5455,0194,6117,2226,8136,4398,4887,7887,54210,4319,6658,82212,96512,12211,14213,39712,65011,74517,71315,81014,86720,67219,72917,75521,87021,54319,897

End1,4381,092779

2,3722,0591,7671,3333,3322,8972,3132,0033,5783,2672,6823,9133,3382,9365,7475,3454,5336,7506,1185,3869,2088,1227,279

12,12411,28110,50914,13512,69012,18217,77316,24014,55422,23720,55018,58922,44020,94619,13629,12225,17923,22434,01332,05827,96835,16034,48231,071

2SA2SB2SC2SB2SC2SD2SE2SD2SE2SF2SG2SF2SG2SH3SA3SB3SC3SB3SC3SD3SE3SF3SG4SA4SB4SC4SB4SC4SD4SE4SF4SG5SA5SB5SC5SB5SC5SD5SE5SF5SG6SA6SB6SC6SB6SC6SD6SE6SF6SG

MODEL

ISR 02-20

ISR 02-25

ISR 02-30

ISR 02-35

ISR 03-35

ISR 03-38

ISR 03-43

ISR 04-43

ISR 04-48

ISR 04-53

ISR 05-53

ISR 05-58

ISR 05-63

ISR 06-63

ISR 06-68

ISR 06-73

Air Torque : Air Supply PressureSPRING TORQUE(Nm) 2.8 BarSPRING

CODE4.2 Bar 5.5 Bar 7 Bar

Spring Return (Fail closed or Fail open) Unit : Nm

Page 8: Heavy-Duty Pneumatic Actuator IS & IC Series

CANTED TECHNICAL DATACANTED TECHNICAL DATA

8 Heavy-Duty Pneumatic Actuator

MODEL

ICD 02-20

ICD 02-25

ICD 02-30

ICD 02-35

ICD 03-35

ICD 03-38

ICD 03-43

ICD 04-43

ICD 04-48

ICD 04-53

ICD 05-53

ICD 05-58

ICD 05-63

ICD 06-63

ICD 06-68

ICD 06-73

ICD 08-73

Start

2,191

3,424

4,930

6,148

7,232

9,552

12,195

15,853

19,707

23,980

29,513

35,288

41,578

51,972

60,479

69,630

66,375

End

1,104

1,725

2,484

3,098

3,645

4,814

6,145

7,989

9,931

12,084

14,873

17,783

20,953

26,191

30,478

35,090

37,892

Run

654

1,022

1,472

1,835

2,159

2,852

3,641

4,733

5,884

7,160

8,812

10,536

12,414

15,517

18,057

20,790

21,538

2.8 Bar

Start

4,304

6,725

9,684

12,075

14,206

18,764

23,954

31,140

38,710

47,103

57,973

69,315

81,670

102,088

118,798

136,773

130,380

End

2,169

3,389

4,880

6,085

7,159

9,456

12,071

15,693

19,508

23,737

29,215

34,931

41,157

51,447

59,868

68,926

74,432

Run

1,285

2,008

2,891

3,605

4,242

5,602

7,152

9,298

11,558

14,064

17,309

20,696

24,384

30,481

35,470

40,837

42,307

5.5 Bar

Start

5,478

8,559

12,325

15,369

18,081

23,881

30,487

39,633

49,267

59,949

73,783

88,219

103,944

129,930

151,197

174,075

165,938

End

2,761

4,313

6,211

7,745

9,112

12,035

15,364

19,973

24,828

30,211

37,183

44,458

52,382

65,478

79,195

87,725

94,731

Run

1,636

2,556

3,680

4,589

5,398

7,130

9,102

11,833

14,710

17,899

22,030

26,340

31,035

38,793

45,143

51,974

53,845

7 Bar

Start

3,287

5,135

7,395

9,221

10,849

14,329

18,292

23,780

29,560

35,969

44,270

52,932

62,366

77,958

90,718

104,445

99,563

End

1,656

2,588

3,727

4,647

5,467

7,221

9,218

11,984

14,897

18,127

22,310

26,675

31,429

39,287

45,717

52,635

56,839

Run

981

1,533

2,208

2,753

3,239

4,278

5,461

7,100

8,826

10,739

13,218

15,804

18,621

23,276

27,086

31,184

32,307

4.2 Bar

Double Acting Unit : Nm

Canted Yoke

Torque Curve Air TorqueSpring Torque

Double Acting Actuator

TOR

QU

E

TOR

QU

E

0o

Closed0o

Closed90o

Open45o

POSITION45o

POSITION90o

Open

Spring Return Actuator

CantedCanted

Page 9: Heavy-Duty Pneumatic Actuator IS & IC Series

9IS & IC Series

CANTED TECHNICAL DATACANTED TECHNICAL DATA

Start830

1,0771,2651,2651,5251,9212,2471,5252,2473,0223,1612,2473,1613,8203,0294,2663,6243,6245,0504,7084,7085,8106,8145,8497,8108,6198,619

10,40811,01411,01411,99113,79713,37515,74616,95916,95920,80919,57719,57721,86424,75526,70729,02132,57132,57135,67839,20739,20742,57846,41838,508

Run407529621621748942

1,102748

1,1021,4831,5511,1021,5511,8741,4482,0401,7331,7332,4152,2512,2512,7783,2582,8133,7564,1464,1465,0065,2975,2975,7686,6366,4167,5538,1358,1359,9829,3919,391

10,48811,75512,63113,72615,40515,40516,87418,54318,54320,13721,95318,449

End981

1,2731,4951,4951,8022,2692,6551,8022,6553,5713,7362,6553,7364,5143,2834,6233,9283,9285,4735,1025,1026,2977,3846,4688,6379,5329,53211,51012,17912,17913,26115,25714,65717,25518,58418,58422,80421,45321,45323,95926,85327,84330,25633,95833,95837,19740,87540,87544,39048,39341,651

Start1,210

1,9291,622

3,1282,275

3,493

3,949

5,624

7,0935,898

9,3857,216

10,175

11,80110,719

14,856

16,704

20,125

Run247

401274

724370

733

711

1,119

1,390863

1,920977

1,738

1,8631,392

2,396

2,401

3,023

End274

460200

959237

851

616

1,190

1,437335

2,140179

1,312

1,07093

1,498

824

1,376

Start

4,2053,983

6,2905,904

8,7548,589

10,855

13,45814,153

18,40818,779

24,19023,103

30,99630,101

37,75737,088

46,68844,692

56,52855,199

65,41566,766

79,98577,091

99,67495,972

114,000110,322

129,685125,682124,287

Run

1,1071,015

1,6141,454

2,1972,129

2,715

3,3583,665

4,7154,879

6,3245,844

8,0777,687

9,7049,413

12,13111,263

14,47713,895

16,35816,949

20,54719,280

25,06723,388

28,26926,600

31,83730,02135,396

End

1,6841,496

2,3922,066

3,1893,050

3,925

4,8465,488

6,9857,327

9,5548,550

12,16311,354

14,42013,814

18,22016,414

21,43720,224

23,64924,881

30,51827,627

36,45732,907

43,51739,988

45,14741,30756,223

Start2,3062,014

3,6403,3332,866

5,5934,7403,824

6,5665,4854,7077,5666,2266,921

10,4018,8569,227

13,19011,99510,90817,31215,14314,24820,02818,05017,38123,79022,70820,71229,61327,01525,68634,34830,12831,47940,91338,40735,51350,11547,70244,00056,76053,52149,84363,57060,05556,05257,912

Run574452

912785591

1,4601,106725

1,6511,202879

1,7911,1991,5062,5451,8632,0273,2102,6832,2034,2873,3442,9544,6803,8203,5295,4424,9714,1036,8025,6655,0837,6695,8226,4139,2308,1336,86610,6459,5507,87111,68110,2128,54312,64111,0479,23113,858

End826579

1,3231,063667

2,2021,480705

2,4001,486827

2,4381,2011,8433,5972,1712,5134,5103,4082,4046,1354,1743,3656,2784,4893,8837,1136,1364,3308,9356,5645,3519,7165,8667,09811,8529,5656,674

12,58010,2666,716

13,14610,0396,510

13,42810,0576,217

18,331

Start3,3233,0312,8095,2304,9234,4564,0707,8827,0296,1135,9489,4208,3397,561

10,9239,583

10,27814,83613,29113,66218,85217,65716,57024,67222,50321,60829,17827,20026,53134,92433,84231,84643,31640,71839,38950,73146,51147,86260,21757,71154,81774,24571,83268,13084,84081,60177,92395,89892,38388,38088,729

Run878756664

1,3871,2601,066906

2,1431,7891,4081,3402,5032,0541,7312,7942,2022,5093,8693,1873,3514,9014,3743,8946,4855,5425,1527,4126,5526,2618,7678,2967,42810,8939,7569,17412,56110,71411,30514,99313,89612,62917,85016,75515,07620,06518,59616,92722,29420,70018,88423,858

End1,3391,092904

2,1241,8641,4681,1423,3552,6331,8581,7193,8382,9242,2654,1302,8933,5355,8324,4064,7487,3636,2615,2579,8447,8837,074

10,8899,1008,494

12,72311,7469,940

15,84013,46912,25617,97214,12215,35421,58019,29316,40224,74022,42618,87627,29724,19020,66129,71926,34822,50835,924

2CA2CB2CC2CC2CG2CD2CE2CG2CE2CF2CH2CE2CH2CI3CA3CB3CC3CC3CD3CE3CD3CF3CG4CA4CB4CC4CC4CD4CE4CE4CF4CG5CA5CB5CC5CC5CD5CE5CE5CF5CG6CA6CB6CC6CC6CD6CE6CE6CF6CG8CA

MODEL

ICR 02-20

ICR 02-25

ICR 02-30

ICR 02-35

ICR 03-35

ICR 03-38

ICR 03-43

ICR 04-43

ICR 04-48

ICR 04-53

ICR 05-53

ICR 05-58

ICR 05-63

ICR 06-63

ICR 06-68

ICR 06-73

ICR 08-73

Air Torque : Air Supply Pressure2.8 Bar 4.2 Bar 5.5 Bar 7 Bar

Spring Return (Fail closed) Unit : Nm

SPRING TORQUE(Nm)SPRING

CODE

Page 10: Heavy-Duty Pneumatic Actuator IS & IC Series

CANTED TECHNICAL DATACANTED TECHNICAL DATA

10 Heavy-Duty Pneumatic Actuator IS & IC Series

Start1,6472,1382,5112,5113,0253,8114,4583,0254,4585,9976,2734,4586,2737,5805,8878,2917,0437,0439,8149,1499,14911,53013,52111,36715,17816,75116,75120,22721,40421,40423,30426,81325,99430,60132,95832,95840,44138,04638,04642,49147,62251,90256,40063,30063,30069,38876,19576,19582,74790,20966,063

Run407529621621748942

1,102748

1,1021,4831,5511,1021,5511,8741,4482,0401,7331,7332,4152,2512,2512,7783,2583,6954,9345,4465,4466,5766,9586,9587,5768,7176,4167,5538,1358,1359,9829,3919,391

10,48811,75512,63113,72615,40515,40516,87418,54318,54320,13721,95318,449

End494642753753908

1,1441,338908

1,3381,8001,8831,3381,8832,2751,6892,3792,0212,0212,8162,6252,6253,1733,7213,3284,4444,9054,9055,9226,2676,2676,8237,8517,5428,8799,5629,56211,73411,03911,03912,32813,81714,32715,56917,47317,47319,14021,03321,03322,84124,90124,278

Start610462

972817

1,5761,146

1,760

1,956

2,793

3,520

4,661

5,026

5,817

7,331

8,221

9,914

11,864

Run247125

401274

724370

733

711

1,119

1,390

1,038

438

202

2,396

2,401

3,023

2,886

End54453

913399

1,905472

1,690

1,345

2,509

3,046

4,486

2,956

2,576

3,519

2,330

3,532

70

Start

2,1192,008

3,1692,975

4,4114,328

5,8625,470

6,7337,091

9,2199,410

12,19111,643

15,52915,068

18,90618,561

23,38822,360

28,30427,621

32,72433,419

40,05438,565

49,90948,00561,72260,05558,16266,69264,88462,82470,453

Run

1,1071,015

1,6141,454

2,1972,129

3,0382,715

3,3583,665

4,7154,879

6,3245,844

6,8996,387

8,1347,752

10,3239,182

14,47713,895

16,35816,949

20,54719,280

25,06723,38829,73828,26926,60033,43131,83730,02135,396

End

3,3402,967

4,7484,101

6,3286,052

9,0967,789

9,79011,038

14,06714,732

18,95716,966

24,45522,882

29,04027,863

36,64533,136

43,18240,825

47,77850,173

61,45356,322

73,53066,63087,89781,85975,00297,88091,32883,86699,875

Start1,1621,014

1,8351,6801,4441,2502,8192,3891,9271,8443,3092,7642,3723,7783,0883,4465,2004,4054,5966,5936,0455,4978,6567,5407,0799,9928,9758,63011,86011,30410,27614,76813,43112,74817,11314,94115,63620,39019,10117,61224,96023,71821,81428,24426,57724,68431,60229,79427,73432,561

Run574452

912785591431

1,4601,106725657

1,6511,202879

1,7911,1991,5062,5451,8632,0273,2102,6832,2033,4052,1661,6543,3802,2501,8683,7813,1632,0226,8025,6655,0837,6695,8226,4139,2308,1336,86610,6459,5507,87111,68110,2128,54312,64111,0479,23113,858

End1,6401,149

2,6242,1101,324677

4,3702,9371,3981,1224,7632,9481,6414,9622,5583,8067,2864,5155,1809,1436,7624,771

12,4138,6027,029

12,8099,3338,156

14,56512,6659,156

18,27613,66911,31219,97412,49114,88624,32019,87514,74426,05621,55814,65827,41821,38014,52328,25021,69814,23633,500

Start1,6751,5271,4162,6362,4812,2452,0513,9723,5423,0802,9974,7474,2023,8105,4704,7805,1387,4356,6406,8319,4468,8988,350

12,36511,24910,78814,60313,58613,24117,47016,91415,88621,67320,33619,65325,36923,19723,89230,11828,82927,34037,12035,87833,97442,39540,72838,83547,89346,08544,02550,154

Run878756664

1,3871,2601,066906

2,1431,7891,4081,3402,5032,0541,7312,7942,2022,5093,8693,1873,3514,9014,3743,8945,6034,3643,8526,1124,9824,6007,1066,4885,34710,8939,7569,17412,56110,71411,30514,99313,89612,62917,85016,75515,07620,06518,59616,92722,29420,70018,88423,858

End2,6572,1661,7934,2143,7002,9142,2676,6595,2263,6873,4117,6175,8024,4958,3195,9157,16311,7218,9509,615

14,80512,42410,43319,77315,96214,38921,95918,48317,30625,69923,79920,29031,97927,37225,01536,35728,87431,26943,62439,17934,04850,18645,68838,78855,49849,46042,60360,57854,02646,56464,317

2CA2CB2CC2CC2CG2CD2CE2CG2CE2CF2CH2CE2CH2CI3CA3CB3CC3CC3CD3CE3CE3CF3CG4CA4CB4CC4CC4CD4CE4CE4CF4CG5CA5CB5CC5CC5CD5CE5CE5CF5CG6CA6CB6CC6CC6CD6CE6CE6CF6CG8CA

MODEL

ICR 02-20

ICR 02-25

ICR 02-30

ICR 02-35

ICR 03-35

ICR 03-38

ICR 03-43

ICR 04-43

ICR 04-48

ICR 04-53

ICR 05-53

ICR 05-58

ICR 05-63

ICR 06-63

ICR 06-68

ICR 06-73

ICR 08-73

Air Torque : Air Supply Pressure2.8 Bar 4.2 Bar 5.5 Bar 7 Bar

Spring Return (Fail open) Unit : Nm

SPRING TORQUE(Nm)SPRING

CODE

Page 11: Heavy-Duty Pneumatic Actuator IS & IC Series

SYMMETRIC CANTED

< DOUBLE ACTING >

G

EF

AB

C I (PCD & TAP)

K

J

H

D

DIMENSION

Heavy-Duty Pneumatic Actuator11

755755755755935935935110511051105131013101310161016101610

A

516516516516653653653763763763904904904112411241124

B

196196196196236236236287287287343343343415415415

C

48739811792118143128153184157183210192217243

D

272322373410410461512514564625625675730745795847

EMODEL

ISD 02-20 (ISR)ISD 02-25 (ISR)ISD 02-30 (ISR)ISD 02-35 (ISR)ISD 03-35 (ISR)ISD 03-38 (ISR)ISD 03-43 (ISR)ISD 04-43 (ISR)ISD 04-48 (ISR)ISD 04-53 (ISR)ISD 05-53 (ISR)ISD 05-58 (ISR)ISD 05-63 (ISR)ISD 06-63 (ISR)ISD 06-68 (ISR)ISD 06-73 (ISR)

800800800800985985985

121512151215143514351435171017101710

A

516516516516653653653763763763904904904112411241124

B

196196196196236236236295295295345345345415415415

C

48739811792118143128153184157183210192217243

D

272322373410410461512514564625625675730745795847

EMODEL

ICD 02-20 (ICR)ICD 02-25 (ICR)ICD 02-30 (ICR)ICD 02-35 (ICR)ICD 03-35 (ICR)ICD 03-38 (ICR)ICD 03-43 (ICR)ICD 04-43 (ICR)ICD 04-48 (ICR)ICD 04-53 (ICR)ICD 05-53 (ICR)ICD 05-58 (ICR)ICD 05-63 (ICR)ICD 06-63 (ICR)ICD 06-68 (ICR)ICD 06-73 (ICR)

Symmetric IS Series Dimension

Canted IC Series Dimension

145145145145175175175190190190230230230260260260

G

145145145145175175175205205205240240240260260260

G

370395420445490505530640657682710732760830850875

F

370395420445490505530640657682710732760830850875

F

Page 12: Heavy-Duty Pneumatic Actuator IS & IC Series

12IS & IC Series

DIMENSIONDIMENSION

< SPRING RETURN >

M

C

B

LPORT SIZE(2 PORT)

I

165165165165254254254298298298356356356406406406

PCDM20/25M20/25M20/25M20/25M16/27M16/27M16/27M20/34M20/34M20/34M30/43M30/43M30/43M36/53M36/53M36/53

TAP/DP54545454

80/8580/8580/85

95.4/105.495.4/105.495.4/105.4

117.4/127.4/137.4117.4/127.4/137.4117.4/127.4/137.4137.4/147.4/157.4137.4/147.4/157.4137.4/147.4/157.4

H

1/2” NPT1/2” NPT1/2” NPT1/2” NPT1/2” NPT1/2” NPT1/2” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT

L

I

165165165165254254254298298298356356356406406406

PCDM20/25M20/25M20/25M20/25M16/27M16/27M16/27M20/34M20/34M20/34M30/43M30/43M30/43M36/53M36/53M36/53

TAP/DP

J

50505050

75/8075/8075/80

90/10090/10090/100

110/120/130110/120/130110/120/130130/140/150130/140/150130/140/150

DIA156156156156204204204234234234279279279326326326

DP

J

50505050

75/8075/8075/80

90/10090/10090/100

110/120/130110/120/130110/120/130130/140/150130/140/150130/140/150

DIA156156156156204204204234234234279279279326326326

DP54545454

80/8580/8580/85

95.4/105.495.4/105.495.4/105.4

117.4/127.4/137.4117.4/127.4/137.4117.4/127.4/137.4137.4/147.4/157.4137.4/147.4/157.4137.4/147.4/157.4

H

14141414202020222222323232323232

K

14141414202020222222323232323232

K

1/2” NPT1/2” NPT1/2” NPT1/2” NPT1/2” NPT1/2” NPT1/2” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT3/4” NPT

L

M

1280128012801280147514751475186018601860224022402240269526952695

4.2 Bar1280128012801280147514751475186018601860224022402240269526952695

5.5 Bar

M

1325132513251325151015101510193519351935232023202320275027502750

4.2 Bar1325132513251325151015101510193519351935232023202320275027502750

5.5 Bar

Page 13: Heavy-Duty Pneumatic Actuator IS & IC Series

ACCESSORIESACCESSORIES

13 Heavy-Duty Pneumatic Actuator

ITS 0

0 : 2 - SPDT1 : 3 - SPDT2 : 4 - SPDT3 : 2 - SPST4 : 2 - DPDT5 : 2 - SPDT + output(0~1Kohm)6 : 2 - SPDT + output(4-20mA)0 : Autonics (PSN17-5DNU-NPN etc)1 : P & F (NJ2-V3-N)M: Monas I-sensorS: Other type sensors

1

1: Weather proof

3: Explosion proof

5: Special material housing (316L, Duplex)

- Model numbers in Green are applicaboe to ITS100, 300 and 500 series- Model numbers in Red are applicable to ITS300 and 500 series

Model number Legend

0

0: Mechanical switches

1 : Proximity sensors

ITS Series Position Monitoring Switch Box

SPECIFICATION STANDARD OPTIONEnclosureOutside coatingAmbient temperatureCable entriesTerminal block Position indicatorMounting bracket

Switches(Sensors)

Weather proof IP67, O-ring sealedEpoxy-Polyester inside and outside -20oC ~ +80oC2 - PT1/2", other standard threads8 nos of terminal stripsDome type 0o~90o

Stainless steel acc. to VDI/VDE 3845, NAMUR, SS1, SS2 as option2-SPDT mechanical switch(Form C)

ITS 300 Series (Explosion Proof)Suitable for valves and actuators in hazardousarea applications conforms to EN50014 and 50018, also suitable in Zone 1 and 2

ITS 500 SeriesSpecial stainless steel housig (316L or Duplex) for extremly corrosive

environmental conditions & for off-shore applications.

Other specifications are shared with the ITS 300 series exceptfor enclosure & coating.

SPECIFICATION STANDARD OPTION

EnclosureOutside coatingAmbient temperatureCable entriesTerminal block Position indicatorMounting bracket

Switches(Sensors)

Explosion proof Ex d llC T6, IP67, O-ring sealedEpoxy-Polyester outside against corrosion-20oC ~ +60oC2 - PF3/4", other standard threads8 nos of terminal stripsDome type 0o~90o

Stainless steel acc. to VDI/VDE 3845, NAMUR, SS1, SS2 as option2-SPDT mechanical switch(Form C)

ITS 100 Series (Weather Proof)

*Ex d : IECEx, ATEX, NEPSI, KC certified*

*Ex d : IECEx, ATEX, NEPSI, KC certified*

Page 14: Heavy-Duty Pneumatic Actuator IS & IC Series

IS & IC SeriesHeavy-Duty Pneumatic Actuator

The details of this catalog are subject to change without prior notification.

CONTROLS Co., Ltd.®

Website : http://www.i-tork.com

© I-TORK® Controls Co., Ltd. All rights reserved. ICS-CA-1603


Recommended