HH H H O O U U ST ST ON ON F F I I RE RE D D E E PA PA RT RT ME ME N N T T P P U U MP MP O O P P ER ER AT AT OR OR P P R R O O GR GR AM AM VAL JAHNKE FIRE TRAINING FACILITY
Transcript
Page 1: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

HHHHOOUUSTSTONON FFIIRERE DDEEPAPARTRTMEMENNTT

PPUUMPMP OOPPERERATATOROR PPRROOGRGRAMAM

VAL JAHNKE FIRE TRAINING FACILITY

Page 2: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.
Page 3: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Pump Equipment

• Centrifugal Pump• Pressure Relief Valve/Governor• Intake Relief Valve• Transfer Valve• Positive Displacement Primers• Manual Pump Shift• Gauges• Auxiliary Cooler

Page 4: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Centrifugal Pump

• Non-positive displacement pump

• Three factors influence pump discharge pressure

1) Incoming pressure, 2) Speed of the impeller, and 3) The amount of water being discharged

• Single or multi-stage• NOT self-priming• Cavitation

Page 5: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Pressure Relief Valve/Governor

• Most common devices

• Set while discharging at operating pressure

• Set for highest operating pressure

• Pressure relief valve - diverts water

• Pressure governor - controls rpm

Page 6: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Intake Relief Valve

• Also known as dump valve

• Protects pump from water hammer and excessive intake pressure

• Possibly capped during high pressure operations

• Piston intake relief valve

Page 7: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Transfer Valve

• Multi-stage pump only

• Pressure (series) vs. Volume (parallel)

• Most operations in pressure mode

• 50% rule

• Change over @ 50 psi net pump pressure

Page 8: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Positive Displacement Primers

• Required for drafting

• Most common - rotary vane

• Operate for no more than 45 seconds

• Priming oil

• Environmentally safe primers

Page 9: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Manual Pump Shift

• Provides back-up

• Usually located on pump panel

• Often require two persons to operate

• Back-up throttle may have to be used

• Exercise manual shift often

Page 10: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Gauges

• Compound gauge

• Master intake gauge (compound)

• Master discharge gauge

• Individual discharge gauge

• Engine gauges

Page 11: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Auxiliary Cooler

• Allows water from pump to cool engine

• Use when temperature exceeds normal level

• Close when temperature returns to normal

• Keep in closed position

Page 12: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Valves

• Main intake valve (suction)-keystone, piston, MIV• Auxiliary intake valve ( 2 ½ ) • Tank-to-pump valve• Tank fill valve• Discharge valves• Pump drain valve• Discharge drain valve• Intake drain valve

Page 13: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Water Supply

Page 14: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Booster Tank

• Sizes

• Tank-to-pump valve

• Use only one handline

• Obtaining positive source

• Refill as soon as possible

Page 15: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Hydrant Operations

• Two types of hydrants

• Steamer should face street

• Blue reflectors assist in locating

• Color coded to main size

• MUD Districts may not color code

• Private hydrants - Apartments, Businesses

Page 16: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Water System Consumption

• Peak use hours

– Morning - residential areas

– Mid day - downtown areas

– Evening - residential areas• May contact Water Department to divert

water to fire area

Page 17: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Drafting

• Primary source for rural fire protection

• Portable water supplies

• Static water supplies

Page 18: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Hydraulics

Page 19: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Theory of Pressure

• Force: measure of weight

• Pressure: measure of force per unit area

Page 20: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Pressure and Fluids

• Pressure acts on fluids according to six basic principles– Fluid pressure is perpendicular to any surface on which it acts.

– Fluid pressure at a point in a fluid at rest is of the same intensity in all directions.

– Pressure applied to a confined fluid from without is transmitted equally in all directions.

– The pressure of a liquid in an open vessel is proportional to its depth.

– The pressure of a liquid in an open vessel is proportional to the density of the liquid.

– The pressure of a liquid on the bottom of a vessel is independent of the shape of the vessel.

Page 21: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Hydraulic Calculations

Engine Pressure = nozzle pressure + friction loss in the hose + friction loss in appliances + pressure due to elevation

Nozzle Pressure - The amount of pressure required at the nozzle to produce an effective fire stream.

Page 22: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Nozzle Pressures

• Fog nozzle 100 psi

• Low pressure fog nozzle 75 psi

• Vindicator nozzle (minimum) 50 psi

• Solid stream handline 50 psi

• Solid stream master 80 psi

Page 23: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Friction Loss

The part of the total pressure lost while forcing water through pipe, fire hose, fittings, adapters, and appliances. The basis for fire hose friction loss calculations are the size of the hose, the amount of water flowing, the length of the hose lay, the age of the hose, and the condition of the lining.

These factors give rise to the formula for computing friction loss: FL = C · Q · L

Page 24: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

FL = C · Q · L

• FL = friction loss in psi

• C = coefficient ( constant )

• Q = flow rate in GPM/100

• L = hose length in feet/100

Page 25: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Friction Loss Coefficients

• 1¾” - 15.5

• 2½” - 2.0

• 3” - .80

• 4” - .20

Page 26: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Example

If 200 gpm is flowing from a nozzle, what is the friction loss in 200 ft. of 2½” hose?

FL = C · Q · L

C = 2

Q = gpm/100 = 200/100 = 2

L = length/100 = 200/100 = 2

FL = (2) (2) (2) = (2) (4) (2) = 16 psi

Page 27: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

GPM Formula

• It is possible to determine water flow from any solid stream nozzle when the nozzle pressure and tip diameters are known. The following formula is used to determine the GPM flow of solid stream nozzles:

GPM = 29.7 ·d2 ·NP

Page 28: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

GPM = 29.7 ·d2 ·NP

GPM= Discharge in gallons per minute

29.7 = A constant

d = Diameter of the tip (inches)

NP = Nozzle pressure in psi (square root)

Page 29: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Example

Determine the water flow from a 2” tip operating at 80 psi.

GPM = (29.7) (d)2 (NP)

= (29.7) (2)2 (80) (use 81)

= (29.7) (4) (9)

= (118.8) (9)

= 1069.2 GPM (1070)

Page 30: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Solid Stream Handline @ 50 psi

Tip Size GPM

1” 210

1 1/8” 265

1 1/4” 325

Page 31: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Solid Master Stream @ 80 psi

Tip Size GPM1 ½” 6001 ¾” 8002” 1000

2 ¼” 13452 3/8” 15002 ½” 1660

Page 32: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Appliances

• Reducers

• Gates

• Wyes

• Manifolds

• Heavy Stream Piping

Page 33: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Appliance Friction Loss

• Small appliances:– Less than 350 GPM - no friction loss– More than 350 GPM - 10 psi friction loss

• Master streams:– 25 psi friction loss

Page 34: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Standpipes

• No friction loss for piping

• Allow for elevation only

• 5 psi per floor for elevation

• Can be negative number– pumping to basement

Page 35: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Total Engine Pressure

• EP = NP + FL + Appliance + Elevation

Page 36: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Example

• What is the engine pressure for 200 ft. of 1¾” hose flowing 200 gpm, with a low pressure fog nozzle, on the third floor?

EP = NP + FL + Appliance + Elevation

EP = 75 + 125 + 0 + 15

EP = 215 psi

Page 37: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Wyed Hoselines

• Complex pumping situation

• Common with apartment lay

• Same size and type

• Different size

• Communication with crews

Page 38: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Pressure vs. Volume

• Common misconception

• Maximum capacity at draft

• Maximum capacity with positive pressure

• Net pump pressure

Page 39: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Calculating Additional Water Available

• Static pressure

• Residual pressure

• Percentage drop: static -residual

• Formula– Percentage Drop = (Static - Residual) (100)

» Static

Page 40: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Water Available Table

Percent Decrease Water Available

0 - 10% 3 x amount

11 - 15% 2 x amount

16 - 25% same amount

Over 25% less than being delivered

Page 41: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Specialized Pump Operations

Page 42: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Multiple Discharges

• Different Pressures

• Different Friction Loss Calculations

• Gating Back Discharges

• Set Pressure Relief Device/Governor

Page 43: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Master Streams

• Most Common - Deck Gun, Ladder Pipe

• Nozzle Tips Flowing 400-1500 GPM

• Solid Bore - 80 psi Nozzle Pressure

• Fog Nozzle - 100 psi Nozzle Pressure

• 25 psi Friction Loss

Page 44: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Standpipes and Sprinklers

• Usually have a 2 ½” connection

• Hook up with 3” high pressure hose or 4” hose with adapter

• Reverse lay

• DO NOT PUMP UNLESS ORDERED

Page 45: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Non-PRV Systems

• Standpipe:– Fog Nozzle: 150 psi + 5 psi per floor– Solid Stream 65 psi + 5 psi per floor

• Sprinkler:– 150 psi + 5 psi per floor

• Elevation loss is calculated to the fire floor

Page 46: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

PRV Systems

• Pump the designed pressure if known

• If the designed system pressure is unknown:– 100 psi + 6 psi per floor to the top floor of the

zone

• When pumping into a PRV system, the standpipe outlet pressure cannot be raised above its designed pressure

Page 47: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Relay Pumping

• Necessary when the required GPM flow of the attack pumper cannot be met because of friction loss in the supply line

• Pump pressure is based on GPM needed and distance between pumpers

• 20-50 psi residual in addition to friction loss

• Relay initiated by pumper at water source

Page 48: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Relay Pumping

• Intermediate pumpers - close pump to tank valve, open 2½” discharge until water discharges, close discharge, place in pump gear and open supply to next pumper

• Discharge pressures should not exceed 200 psi, if pressure required to supply water is greater than 200 psi, another pumper or additional lines are needed

Page 49: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Relay Pumping

• Relay is designed to deliver volume not pressure

• Relay is terminated by attack pumper by decreasing pressure, followed by next pumper in relay, etc.

Page 50: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Foam OperationsPortable Eductors

• Do not start foam operations unless incident can be terminated with resources available

• Portable eductors require 200 psi @ eductor• Emulsifiers can be educted @ 1/2 or 1%• Nozzle setting must be @ 95 gpm• Apparatus will carry 6 - 5 gallon containers

of foam and 2 - 5 gallon containers of cold clean

Page 51: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Foam Operations

• Portable eductors must be flushed with clean water to prevent gumming of the pick-up tube. Flush the entire hoseline for approximately 5 minutes.

• Rotate the proportioning valve while flushing

• Maximum length from eductor to nozzle is 300 ft of 1 3/4” hose or a combination of 1 3/4” and 2 1/2” hose not exceeding 450 ft

Page 52: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Permanently Mounted Eductor

• Similar to portable eductor

• Require same pressure @ eductor

• Maximum hose length from eductor to nozzle - 300 ft of 1 3/4” hose or a combination of 1 3/4” and 2 1/2” hose not exceeding 450 ft

• Proportioning valve located on pump panel

Page 53: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Direct Injection Foam System

• Uses a pump to inject the emulsifier/foam into a discharge pipe that connects the fire pump and designated foam discharges

• Controlled by electronic keypad

• Two tanks - 40 gallons foam, 10 gallons emulsifier

• System is self adjusting, regulated by flow meter

Page 54: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Direct Injection Foam System

• Intake pressure kept below 50 psi• Minimum pump pressure is intake pressure

plus 100 psi• Maximum pump pressure 250 psi• Set engine pressure according to hoselay and

nozzle• Foam and emulsifier flows only through

designated discharges

Page 55: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Direct Injection Foam System

• Can flow water through non-foam discharges simultaneously

• To flush system, decrease pump pressure to 100 psi and place toggle switch in flush position - flush system for 20 seconds

• Turn foam system off and flush hoseline for 5 minutes

Page 56: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Drafting

• 3 primary considerations for selecting a site;

1) Amount of water available

2) Type of water available

3) Location accessibility

• Source should have 24 inches of water above and below the strainer

• Maximum lift is 20 feet

Page 57: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Drafting

• Use side intakes

• Close pump to tank valve

• Remove keystone or piston intake

• Connect hard suction

• Can prime either in or out of pump gear

• When in pump gear, increase rpm’s to 1200 and pull primer for not more than 45 sec.

Page 58: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Drafting

• Priming typically requires 15-20 seconds• Most common problem is air leak• After pump has been primed, increase pump

pressure to 50-100 psi prior to opening any discharge

• Open discharge valve SLOWLY• If pressure drops, momentarily engage primer

Page 59: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

Drafting

• Do not engage pressure governor until flowing water

• If pressure governor is on prior to obtaining prime and apparatus is in pump gear, will sense increase in rpm without corresponding increase in pressure and return engine to idle.

• Flush pump with clean water ASAP

Page 60: HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE FIRE TRAINING FACILITY.

HHHHOOUUSTSTONON FFIIRERE DDEEPAPARTRTMEMENNTT

PPUUMPMP OOPPERERATATOROR PPRROOGRGRAMAM

VAL JAHNKE FIRE TRAINING FACILITY


Recommended