32
CE 0694 TA01E011.A0405 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH High Efficiency Condensing Wall Hung Boiler Heating Only RK 50 Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA05E011.D0905 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH
Transcript
Page 1: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

CE 0694 TA01E011.A0405 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

High Efficiency Condensing Wall Hung Boiler

Heating Only

RK 50 Suitable for Cascade Systems

SEDBUK BAND A

CE 0694 TA05E011.D0905 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

Page 2: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45
Page 3: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

INDEX

• Introduction pag. 1

• Product information

◦ Overall Dimensions 2

◦ Main components 3

◦ Operating Diagram 4

◦ Specification text 5

◦ Technical Data 6

◦ Electric Wiring 8

• Installation information

◦ Single Boiler installation 9

◦ Single boiler + storage cylinder installation 10

◦ Cascade installation 12

• Flue Information

◦ Flue Kit options for a single boiler installation 14

◦ Flue Kit options for cascade installations 15

• Controls – Temperature control systems 16

• System information

◦ Single boiler installation system 17

◦ Cascade installation system 19

• Approvals 22

• Accessories 23

Page 4: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

Introduction RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

1

High flexibility of installation!

High Efficiency Condensing wall hung boiler mod. RK 50, with a premixed combustion exchanger system

for heating only. It can work as a single boiler or as an independent unit in a cascade system.

The right solution for specification designers due to its flexibility of installation.

The right product for installers due to the wide variety of accessories for simple and trouble free

installation.

Advantage for the final user

energy saving, environmentally friendly suitable for both individual and multiply boiler installations.

model: RK 50 ◦ Self-Diagnostic ◦ Combustion chamber type: ROOM SEALED◦ Output: 50 kW ◦ Premix and condensing ◦ Stainless Steel Condensing Exchanger ◦ High Efficiency (107,9 %) ◦ Single or cascade installation ◦ Compact Dimensions: mm. 490x470x700 ◦ CE Approval: no. 0694BP0446 ◦ Sedbuk BAND A

Page 5: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

Overall Dimensions RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

2

KEY

Ø 1"1/4

Ø 1"1/4HEATING FLOW

HEATING RETURNRA

GSC CONDENSE CONNECTION

GAS Ø 3/4"

Ø 25

G

SC

AR

SCR G A

70210 210

700

210280

108 112270

470

78

198

165

364

10752

54

123490

336

134

470

470

490

Ø 3/4"SAFETY VALVE DISCHARGEVS

VS

Page 6: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

Main Components RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

3

3

14

4

18

9

12

17

16

5

144 3

1

21

15

11

9

21

2121

10

11

8

19

21

22

4

5

23

12

FRONTRIGHT SIDE

LEFT SIDE

25

25

22

20237

13

146

24

POS. DESCRIPTION 1 CONDENSATE PIPES CONNECTION 2 FLUE EXHAUST BUSH 3 PUMP WITH AIR VENT 4 FAN 5 CONDENSING EXCHANGER 6 MANIFOLD FLOW 7 MANIFOLD RETURN 8 (SIPHON) OR WATER TRAP 9 FLUE EXHAUST DUCT 10 BURNER OUTLET RUBBER HOSE 11 CONDENSATE OUTLET RUBBER HOSE 12 AIR COMBUSTION INTAKE PIPE 13 4 BAR SAFETY VALVE 14 ELECTRONIC GAS VALVE VK4115V 15 (VENTURI) MIXING GROUP

16 HEATING SAFETY THERMOSTAT (HIGH LIMIT THERMOSTAT)

17 FLUE SAFETY THERMOSTAT 18 HEATING SENSOR 19 ELECTRONIC IGNITION BOARD 20 BOILER DRAIN POINT 21 IGNITION ELECTRODE 22 FLAME IONISATION PROBE 23 CONDENSATE OUTLET HOSE 24 WATER PRESSURE SWITCH 25 EXHAUST TEST SOCKET

Page 7: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

Operating Diagram

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

4

17

12

5

8

G SC AR

18

19

14

1

2

1113

6

4

15

167

3

9

10

POS. DESCRIPTION 1 PUMP 11 HEATING SAFETY THERMOSTAT 2 AIR VENT 12 FLUE SAFETY THERMOSTAT 3 FAN 13 HEATING SENSOR 4 CONDENSING EXCHANGER 14 BOILER DRAINING TAP 5 BURNER 15 IGNITION ELECTRODES (X2) 6 FLUE EXHAUST DUCT 16 FLAME IONISATION PROBE 7 AIR COMBUSTION INTAKE PIPE 17 CONDENSATIE OUTLET HOSE 8 4 BAR SAFETY VALVE 18 SIPHON) WATER TRAP 9 ELECTRONIC GAS VALVE VK4115V 19 WATER PRESSURE SWITCH 10 (VENTURI) MIXING GROUP

KEY

R - HEATING RETURN SC - CONDENSATE DRAINING POINT G - GAS A - HEATING FLOW

Page 8: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

Specification Text

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

5

Wall hung high efficiency condensing boiler – main components specification: : − Premixed stainless steel combustion exchanger system with stainless steel radial gas burner equipped with 2

ignition electrodes and flame ionisation probe; − Condensing exchanger with primary coil type exchanger gas/water in AISI 316L stainless steel material; − Room sealed combustion chamber with separate air intake and flue exhaust connections. − Variable speed Exhaust fan; − System temperature flow sensor; − High limit thermostat; − Circulating pump with automatic air vent; − Water pressure switch; − Condensate draining circuit including trap (siphon) and flexible pipe; − Control Panel with microprocessor controlled electronic printed circuit board for a continuous modulation;

possibility of outside temperature sensor connection, dhw production priority control. − Short cycling device in heating mode, frost protection, pump inactivity protection, chimney sweeper (test

function); − External casing panels; − Operational parameters setting through touch pads and monitoring of operation mode through the digital

display; − Digital display showing the self-diagnostic function through error codes, the operating temperatures and

settings; Safety Features: − Self-diagnostic; − Water pressure switch: water deficiency control and boiler lock-out in case of low or zero water pressure. − High limit thermostat: high temperature control across the primary exchanger; − Flue safety thermostat: high temperature control across the flue exhaust; − 4 bar safety valve – primary circuit; − Frost protection; Suitable for: − Operation in a cascade installation system (up to 4 boilers); − Operation in a single boiler installation and connection to a remote storage cylinder through an external 3-way

valve and domestic hot water temperature sensor, for the domestic hot water production; − Operation in a cascade installation controlled by a cascade regulator system, heating flow sensor and outside

temperature sensor. Technical specification − Device Gas Category II2H3+

− Gas: Natural Gas or L.P.G. . − Modulation range: 12÷51 kW; − Output (80-60°C): 49.90 kW − Output (50-30°C): 54.50 kW − Heating temperature setting: 25÷85°C − Dimensions: 490x700x470 − Electrical protection: IPX4D − CE Approval – Sedbuk Band A

Page 9: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

technical data

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

6

Technical Data CE certification no. n° 0694BP0446 Flue category (UNI10642) B23, C13, C33, C43, C53, C63, C83 Heat Input max kW 51 Heat Input min kW 12 Heat Output max (80/60°) kW 49,88 Heat Output max (50/30°) kW 54,47 Heat Output min (80/60°) kW 11,65 100% Efficiency 100% (80/60°) % 97,8 Efficiency 100% (50/30°) % 106,8 Efficiency 30% (80/60°) % 101,8 Efficiency 30% (50/30°) % 107,9 Gas Directive 92/42/ECC - Efficiency marking stars 4 Sedbuk band A Heating circuit Central heating water temperature setting (min-max) °C 30-80 / 25-40 Max. heating temperature °C 90 Max. working pressure (heating) bar 5 Primary circuit water content litres 3.5 Dimensions Width mm 490 Height Height 700 Depth mm 470 Weight kg 80 Hydraulic connections Flow connection Ø 1”1/4 Return connection Ø 1”1/4 Gas connection Ø 3/4” Flue systems Horizontal single pipe flue system - KIT AK50 Ø mm 125/80 Max. flue length m 5 Vertical-Coaxial flue system - KIT CK50 Ø mm 125/80 Max. flue length m 5

Gas Supply Natural Gas G 20 Inlet pressure mbar 20 Gas consumption m3/h 5,40 Liquid Butane Gas G 30 Max. Inlet pressure mbar 30 Gas consumption kg/h 4.20 Liquid Propane Gas G 31 Max. Inlet pressure mbar 37 Gas consumption kg/h 3.96

Electrical supply Power Supply V/Hz 230/50 Electrical power consumption W 195 Electrical protection IP X4D

Page 10: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

technical data

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

7

Combustion specification Combustion Efficiency % 97.9

Flue efficiency losses with burner on (100% Output) % 2.1

Flue efficiency losses with burner on (Min. Output) % 2.9

Casing efficiency losses (100% Output) % 0.1

Casing efficiency losses (Min. Output) % 1

Fumes temperature at nominal output °C 65.6

Fumes temperature at minimum output °C 60

Fumes flow rate at Nominal Output kg/h 80

Fumes flow rate at minimum Output kg/h 19.7

CO2 value at nominal output % 9.66

CO2 value at minimum output % 9.2

CO value at nominal output ppm 10

CO value at minimum output ppm 5 NOx ppm 20 NOx mg/kWh 35 NOx class (European Standard UNI EN 297 – pr A5 stars 5

PUMP PERFORMANCE CHART

2200 2400 2600

RSL 15/7

8002000

10

0400 600

20

1000 200014001200 18001600

Hea

d kP

a

40

30

70

50

60

Flow rate litres/h

Page 11: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

electric wiring

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

8

SR

47

M4

brown

light-blue 1918

P

4546red

SS

(WIT

H R

EMO

TE B

OIL

ER)

TA50

Hz

59

orange

light-bluebrown

85

67

M2

91

32

light

-blu

e

M8

5048

49

white

M9

5655

5758

brown

black

brown

orange

M10

M1

452

5153

54

orange

IG

black

black

6061

black

LN

orange

PO

WE

R S

UP

PLY

LIN

K

FAN

PR

INTE

D C

IRC

UIT

BO

ARD

SK

1100

1 C

OD

. 766

58LA

black

white

brown

green

yellow 7071

7273

74

M12

+5V

TP1

CM

2

PW

M

6R

V +20

V9

M2

87

GN

D

R156A

1

5M

OD

+V

42

3 HS

-V

P1

CM

1

P2

M1

13

P.C

.B. P

LUG

1.5

bar

1110

12

230V

SE

S45

65P

D20

20

brownlight-blue

white

brown

red

TS

1112

108

9 6

7lig

ht-b

lue

1416

1517

pwm

-

brow

nbl

ack

grey

grey

light

-blu

e

blac

k

Hsps

+

M3

brown

black

light-blue

ps

230

V A

C

NL

Hz

53

41

2br

own

pwm

ps

Hs+

-

ps

M3

M5

M4

M2

M1

PR

INTE

D C

IRC

UIT

BO

AR

D C

VI-M

SM

200

15 C

OD

. 766

55LA

M6

M7

M11

M13

M9

M10 M12

M8

DIS

PLA

Y D

IGIT

AL

BO

AR

D 2

000

SK

O62

06

(CO

D. 7

6654

LA)

- HEA

TIN

G S

EN

SO

R- M

AIN

SW

ITC

HP

AC- W

ATE

R P

RE

SS

UR

E S

WIT

CH

- PU

MP

SR

PIG

- NEU

TRA

L- L

INE

KEY

L N

- IG

NIT

ION

ELE

CTR

OD

E

- FA

N- I

ON

ISA

TIO

N E

LEC

TRO

DE

EVER

EA- R

OO

M T

HE

RM

OS

TAT

- OU

TDO

OR

SE

NS

OR

TE

MP

ER

ATU

RE

- SA

FETY

TH

ERM

OS

TAT

TS TASE

ELE

CTR

ON

IC IG

NIT

ION

BO

AR

DS

4565

PD

2020

- co

d. 7

6657

LA

FAN

tipo

RG

128/

1300

-361

2

L

LMN

1112

9 10

78

56

43

21

Page 12: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

single boiler installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

9

A wide choice of accessories has been designed to ensure the highest flexibility of installation.

The solution described below allows to manage different flow rates between the primary and the secondary with

the use of a compensator.

SC CONDENSE DRAIN POINT Ø 25

110 360

2612

5LP

455

185

700

1740

KEY

STRAINER5ISOLATING VALVE4TUNDISH3

2EXPANSION VESSEL CONNECTION (Ø3/4")14 BAR PRESSURE SAFETY VALVE

4

1

MIRI

2611

0LP

4

5

Ø 3/4"

Ø 3/4"

Ø 2"

Ø 2"HEATING FLOW

HEATING RETURN

TUNDISH SI

RIG

MI

GAS

26110LP26125LP

HYDRAULIC CONNECTIONS

ACCESSORIES6 WATER PRESSURE GAUGE CONNECTION SOCKET (Ø1/8”)

4

6

7

FILLING LOOP CONNECTION (Ø1/2")7HYDRAULIC COMPENSATOR KIT FOR SINGLE BOILER INSTALLATION Ø2"

CONNECTION KIT

Page 13: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

single boiler + DHW storage cylinder installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

10

A single boiler installation connected to a storage cylinder for the DHW production with the use of a ‘3-way valve Kit’

SC CONDENSE DRAIN POINT Ø 25

110 360

2612

5LP

2609

7LP

455

250

185

700

1740

ACCESSORIES

26110LP

26125LP

26097LP3-WAY VALVE KIT FOR REMOTE CYLINDER CONNECTION

43

2

1

MB

RB

MIRI

2611

0LP

4

5

Ø 1"

Ø 1"EXTERNAL CYLINDER RETURN

EXTERNAL CYLINDER FLOWMBRB

Ø 3/4"

Ø 3/4"

Ø 2"

Ø 2"

HYDRAULIC CONNECTIONS

TUNDISH SI

RI

G

MI

GAS

HEATING FLOW

HEATING RETURN

HYDRAULIC COMPENSATOR KIT FOR SINGLE BOILER INSTALLATION Ø2"

CONNECTION KIT

4 BAR PRESSURE SAFETY VALVE

1 EXPANSION VESSEL CONNECTION (Ø3/4")

23 TUNDISH

4 ISOLATING VALVE

5 STRAINER

KEY

7 FILLING LOOP CONNECTION (Ø1/2")

WATER PRESSURE GAUGE CONNECTION SOCKET (Ø1/8”)6

7

6

(code 31219LA - " DHW SENSOR " INCLUDED)

Page 14: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

accessories - single boiler installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

11

Connection Kit - code 26110LP For a direct connection to the boiler. On the return connection a strainer has been included to protect the boiler from eventual impurities that can cause obstructions. Key 1. strainer 2. isolating valve 3. expansion vessel connection (Ø3/4”) 4. water pressure gauge connection (Ø1/8”) 5. filling loop connection (Ø1/2”)

Hydraulic compensator Kit - code 26125LP The use of a compensator is recommended when there is a primary circuit with its own circulating pump and a secondary circuit with one or more circulating pumps. The compensator will negate situations whereby the different pumps of the circuit will interact one with another creating abnormal flow variations. The compensator will create a low pressure loss zone so that the primary circuit (of the boiler) will become independent from the secondary circuit to guarantee flexibility of installation and on systems with several pumps, high flow rates and high pump heads. Key 1. washers (x2) Ø1”1/2; 2. washers (x2) Ø2”1/2; 3. hydraulic compensator 4. Ø2”1/2 => Ø2” adapter

3-Way valve Kit - code 26097LP It is possible to connect the boiler to a remote storage cylinder for the domestic hot water production by installing the 3-Way valve Kit. The kit includes a 3- Way valve (to be fitted onto the return), a cylinder DHW temperature sensor (8 metres length) that will be connected to the boiler main pcb to enable the correct setting and data display (DHW temperature) Key 1. flow manifold Ø1”1/2; 2. return manifold Ø1”1/2; 3. 3-Way valve; 4. Storage cylinder DHW temperature sensor

2

1

2

Ø1"1/2

Ø1"1/2

Ø1"1/2

Ø1"1/2

3

4

5

2

Ø1"1/2

Ø 1"1/21

4

2

4

2

Ø 2"

Ø 2"

1

3

RETURNHEATIN G H EATING

FLO W

3

2 1

Ø 1"1/2

Ø 1"1/2 Ø 1"1/2

EXTERNAL CYLINDER FLO W Ø 1"

EXTERNAL CYLIN DER

RETURN Ø 1"

Ø 1"1/2

Page 15: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

cascade installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

12

1 3IS

OLA

TIN

G V

ALV

E

4

TUN

DIS

H2 5

STR

AIN

ER

NO

N-R

ETU

RN

VA

LVE

HYD

RA

ULI

C M

AN

IFO

LD K

IT F

OR

AD

DIT

ION

AL

BO

ILE

R IN

CA

SC

AD

E26

100L

PH

YDR

AU

LIC

MA

NIF

OLD

KIT

FO

R 2

BO

ILE

RS

CA

SC

AD

E IN

STA

LLA

TIO

N

2609

9LP

FLU

E M

AN

IFO

LD K

IT D

.125

FO

R C

AS

CA

DE

INS

TALL

ATI

ON

FLU

E M

AN

IFO

LD K

IT D

.125

FO

R A

DD

ITIO

NA

L C

AS

CA

DE

INS

TALL

ATI

ON

8210

4LP

8210

3LP

AC

CE

SS

OR

IES

HEA

TIN

G

RET

UR

N

Ø 1

"1/2

Ø 1

"1/2

EXT

ER

NA

L C

YLIN

DE

R R

ETU

RN

EXT

ER

NA

L C

YLIN

DE

R F

LOW

RM RR

2609

9LP

2610

0LP

8210

3LP

8210

4LP

SI

KE

Y

GA

S

CM G

CR SI

TUN

DIS

H

HEA

TIN

G R

ETU

RN

MA

NIF

OLD

HE

ATI

NG

FLO

W M

AN

IFO

LDD

N 6

5 P

N6

DN

65

PN

6

Ø 3

/4"

Ø 3

/4"

HY

DR

AU

LIC

CO

NN

EC

TIO

NS

4 B

AR

PR

ES

SU

RE

SA

FETY

VA

LVE

HEA

TIN

G

FLO

W

Page 16: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

accessories - cascade installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

13

Hydraulic manifold Kit for cascade installation For the installation of 1 or more boilers in a cascade installation up to a maximum of 4 boilers: − Hydraulic manifold Kit for no.2 boilers in cascade installation (cod. 26099LP); − Hydraulic manifold Kit for 1 additional boiler in cascade installation (cod. 26100LP); Hydraulic manifold are equipped with: − Isolating valves to guarantee ease of maintenance or a the temporary exclusion of 1 boiler without interrupting

the operation of the whole cascade installation. − Non-return valve for every single boiler to prevent any circulation when boiler is OFF; − Line Strainer to protect the boiler from eventual obstruction created by impurities of the hydraulic circuit.

1

DN 65 PN6

DN 65 PN6

8

34

5

26100LP26099LP

2

6

7HEATINGRETURN

FLOWHEATING

Key 1. Strainer 2. 3-Way isolating valve 3. Isolating valve 4. Hydraulic connector to the flow manifold Ø1”1/2 5. Hydraulic connector to the return manifold Ø1”1/2 6. Flow manifold Ø2”1/2 7. Return manifold Ø2”1/2 8. Non-Return valve Ø1”1/2

Page 17: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

flue kit options (polypropylene)

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

14

The RK 50 boiler has been approved for an indoor and also outdoor installation.

For the correct operation of the unit it is highly recommend to use only original Radiant flue kit, flue accessories and parts.

Flue Kits are in polypropylene material to guarantee the highest mechanical resistance to the chemical action of the condensate and an easy installation. Flue Kit Options for SINGLE BOILER INSTALLATION Max Flue Length: kit EK50 - Horizontal single pipe flue kit Ø80 – code 82107LP; depending by flue system data kit FK50 - Vertical single pipe flue kit Ø80 – code 82106LP; 3 metres kit AK50 - Horizontal-Coaxial flue kit Ø125/80 – code 82109LP; 5 metres kit CK50 - Vertical-Coaxial flue kit Ø125/80 – code 82110LP; 5 metres

Kit EK50 code 82107LP;

Kit AK50 code 82109LP;

Kit FK50 code 82106LP;

Kit CK50 code 82112LP;

Page 18: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

flue kit options (polypropylene)

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

15

Flue Kit systems for cascade installation

With cascade installation combustion emissions have to be discharged in only one flue duct through the installation of flue manifolds.

Available flue manifolds:

Kit MK50 - Flue Manifold Kit for no. 2 boilers in cascade installation – cod. 82103LP; Kit SK50 - Flue Manifold for 1 additional boiler in cascade installation – cod. 82104LP;

Flue Parts are in polypropylene material to guarantee the highest mechanical resistance to the chemical action of the condensate and an easy installation. The Flue Manifold Kit allows to connect the boiler to the main flue duct through a supplied connector with a mechanical non-return damper to avoid a flue return in cases where one or more boilers are not in operation.

82104LP82103LP

Page 19: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

system controls / regulators

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

16

The purpose of a high efficiency condensing boiler installation is to have a thermal system supplying exactly the right amount of power in the most efficient way. In order to satisfy the various system requirements for either single or cascade installations, radiant offers a wide choice of controls that optimize the system temperature regulation according to the boiler operation. Single Boiler Installation − Single Zone – if the boiler operates within a single zone it is recommended to use a chronostat (Remote

Control LCD – code 52535LP) and an outside temperature sensor (code 73506LA) or a standard type chronostat:

− Multiple Zones – it is necessary to use the Cascade systems regulator (76669LA) together with a zone control room thermostat (76670LA) for each zone;

Cascade Installation: − Cascade systems regulator (76669LA) together with the zone control room thermostat (76670LA) for each

zone; Cascade system regulator Zone control room thermostat Heating flow sensor Electronic regulator for cascade installation control

Room thermostat for the single zone control

Heating flow sensor for the regulation of system temperature

code: 76669LA code: 76670LA code: 31276LA

External sensor D.H.W. storage cylinder sensor Remote Control LCD External sensor for the heating flow temperature control

Dhw sensor for the storage cylinder temperature control

Total boiler control

code: 31277LA code: 31278LA code: 52535LP

External sensor (for Remote control LCD)

External sensor for the heating flow temperature control – to be use combined with Remote Control LCD

code: 73506LA

Page 20: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

system example individual boiler + DHW storage cylinder

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

17

EX

TER

NAL

SEN

SO

Rco

de 7

3506

LA

CO

ND

ENSA

TIO

N

OU

TLET

NO

TETH

ER

E IS

A S

TRA

INER

ON

TH

E H

EAT

ING

CIR

CU

IT..

THE

INS

TALL

ATI

ON

OF

AN

AD

DIT

ION

AL

STR

AIN

ER O

N T

HE

SE

CO

ND

AR

Y C

IRC

UIT

IS R

ECO

MM

EN

DED

.

HEA

TIN

G

RET

UR

N

HEA

TIN

G

FLO

W

GA

S

REM

OTO

LC

Dco

de 5

2535

LP

STO

RA

GE

CYL

IND

ER

DH

W

TEM

PE

RA

TUR

E S

ENS

OR

code

312

19LA

Page 21: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

system example individual boiler + DHW storage cylinder

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

18

CO

ND

ENSA

TIO

N

OU

TLET

87

5

FILL

ING

LO

OP

NO

TETH

ER

E IS

A S

TRA

INE

R O

N T

HE

HEA

TIN

G

CIR

CU

IT.

THE

INS

TALL

ATI

ON

OF

AN

AD

DIT

ION

AL

STR

AIN

ER

ON

TH

E S

ECO

ND

AR

Y C

IRC

UIT

IS

RE

CO

MM

EN

DE

D.

KEY

1R

K 5

0

2C

ASC

AD

E SY

STEM

REG

ULA

TO

R3

ZO

NE

CO

NT

RO

L R

OO

M T

HER

MO

STA

T4

EXT

ERN

AL

SEN

SOR

5M

AN

IFO

LD F

LOW

SEN

SOR

6H

EAT

ING

FLO

W S

ENSO

R7

D.H

.W. S

TO

RA

GE

CY

LIN

DER

SEN

SOR

83-

WA

Y M

IXIN

G V

ALV

E

WA

LL E

XPO

SED

TO

NO

RTH

1

GA

S

Zone

n° 2

Zone

n° 1

6

33

4

2

6

Page 22: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

system example – cascade installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

19

8

4

KEY

1R

K 5

0

2C

ASC

AD

E SY

STEM

REG

ULA

TO

R3

ZO

NE

CO

NT

RO

L R

OO

M T

HER

MO

STA

T4

EXT

ERN

AL

SEN

SOR

5M

AN

IFO

LD F

LOW

SEN

SOR

6H

EAT

ING

FLO

W S

ENSO

R7

D.H

.W. S

TO

RA

GE

CY

LIN

DER

SEN

SOR

83-

WAY

MIX

ING

VA

LVE

NOTE

THE

RE

IS A

STR

AIN

ER

ON

TH

E

HE

ATI

NG

CIR

CU

IT.

THE

INS

TALL

ATI

ON

OF

AN

A

DD

ITIO

NA

L S

TRA

INE

R O

N T

HE

S

EC

ON

DA

RY

CIR

CU

IT IS

R

EC

OM

ME

ND

ED

.

Zone

n° 2

Zone

n° 1

11

11

7

6

2

33

5

GA

S

WA

LL E

XPO

SED

TO

NO

RTH

FILL

ING

LO

OP

CO

ND

ENSA

TIO

N

OU

TLET

Page 23: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

system example – cascade installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

20

8

8

9

6Zone

n° 4

Zone

n° 3

6

33

CO

ND

ENSA

TIO

N

OU

TLET

FILL

ING

LO

OP

WA

LL E

XPO

SED

TO

NO

RTH

GA

S

5

33

2

6

7

11

11

Zone

n° 1

Zone

n° 2

NOTE

THE

RE

IS A

STR

AIN

ER

ON

TH

E

HE

ATI

NG

CIR

CU

IT.

THE

INS

TALL

ATI

ON

OF

AN

A

DD

ITIO

NA

L S

TRA

INE

R O

N T

HE

S

EC

ON

DA

RY

CIR

CU

IT IS

R

EC

OM

ME

ND

ED

.

KEY

1R

K 5

0

2C

ASC

AD

E SY

STEM

REG

ULA

TO

R3

ZO

NE

CO

NT

RO

L R

OO

M T

HER

MO

STA

T4

EXT

ERN

AL

SEN

SOR

5M

AN

IFO

LD F

LOW

SEN

SOR

6H

EAT

ING

FLO

W S

ENSO

R7

D.H

.W. S

TO

RA

GE

CY

LIN

DER

SEN

SOR

83-

WA

Y M

IXIN

G V

ALV

E

4

8

Page 24: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

system example – cascade installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

21

5

8

11

11

GA

S

33

2

6

7

11

11

Zone

n° 1

Zone

n° 2

4

KEY

1R

K 5

0

2C

ASC

AD

E SY

STEM

REG

ULA

TO

R3

ZO

NE

CO

NT

RO

L R

OO

M T

HER

MO

STA

T4

EXT

ERN

AL

SEN

SOR

5M

AN

IFO

LD F

LOW

SEN

SOR

6H

EAT

ING

FLO

W S

ENSO

R7

D.H

.W. S

TO

RA

GE

CY

LIN

DER

SEN

SOR

83-

WA

Y M

IXIN

G V

ALV

E

NOTE

THE

RE

IS A

STR

AIN

ER

ON

TH

E H

EA

TIN

G

CIR

CU

IT.

THE

INS

TALL

ATI

ON

OF

AN

AD

DIT

ION

AL

STR

AIN

ER

ON

TH

E S

EC

ON

DA

RY

CIR

CU

IT

IS R

EC

OM

ME

ND

ED

.

WA

LL E

XPO

SED

TO

NO

RTH

CO

ND

ENSA

TIO

N

OU

TLET

Page 25: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

CE Approval RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

22

Page 26: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

System Controls / Regulators

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

23

Cascade system regulator Zone control room thermostat Heating flow sensor Electronic regulator for cascade installation control

Room thermostat for the single zone control

Heating flow sensor for the regulation of system temperature

code: 76669LA code: 76670LA code: 31276LA

External sensor D.H.W. storage cylinder sensor Remote Control LCD External sensor for the heating flow temperature control

Dhw sensor for the storage cylinder temperature control

Total boiler control

code: 31277LA code: 31278LP code: 52535LP

External sensor (for Remote control LCD)

External sensor for the heating flow temperature control – to be use combined with Remote Control LCD

code: 73506LA

Page 27: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

hydraulic accessories

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

24

Hydraulic manifold kit for 2 boilers cascade installation

Hydraulic manifold kit for additional boiler in cascade

3-way valve kit for remote cylinder connection (DHW sensor included)

Kit for 2 boilers installation: it includes isolating valves, non-return valve, srainer for each boiler.

For 1 additional boiler: it includes isolating valves, non-return valve, srainer for 1 additional boiler

For a remote storage cylinder installation. It includes 31219LA DHW temperature sensor

code: 26099LP code: 26100LP code: 26097LP

Hydraulic compensator kit for single boiler installation

Connection Kit for single boiler installation

System full control also with non-constant water flow rates.

It includes: isolating valves, srainer .

code: 26125LP code: 26110LP

Page 28: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

flue accessories cascade installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

25

Flue manifold kit MK50 Ø125 for 2 boilers in cascade installation

Flue manifold kit SK50 Ø125 for 1 additional boiler in cascade

Extension Kit for flue manifold Ø125

For 2 boilers in cascade installation: complete with no return dampers and condensate trap.

Equipped with no return damper for cascade installation

L = 1 m

code: 82103LP code: 82104LP code: 82105LP

Extension Kit for flue manifold Ø125 90° flue bend Ø125 MF extension kit in PP

45° flue bend Ø125 MF extension kit in PP

L = 0.5 m

code: 82113LP code: 82119LA code: 82120LA

Page 29: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

flue accessories single boiler installation

RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only

26

Kit AK50 - Horizontal-coaxial flue kit Ø125/80 (PP inside)

Kit CK50 - Vertical-Coaxial flue system Ø125/80 (PP inside)

1 mt. extension Ø125/80 MF (PP inside)

For the exhaust of combustion products and air intake through the coaxial pipes.

L = 1 m

code: 82109LP code: 82112LP code: 82118LA

45° flue bend Ø125/80 MF extension (PP inside)

90° flue bend Ø125/80 MF extension (PP inside)

Kit EK50 - Flue kit Ø80 – single pipe in PP

To exhaust combustion products into a flue duct.

code: 27088LA code: 27089LA code: 82107LP

Kit FK50 - Vertical single pipe flue system Ø80 in PP

90° flue bend Ø80 MF extension kit in PP

45° flue bend Ø80 MF extension kit in PP

code: 82106LP code: 27055LA code: 27056LA

1 mt. extension Ø80 MF in PP

code: 82090LP

Page 30: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45
Page 31: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45
Page 32: High Efficiency Condensing Wall Hung Boiler Heating Only · electric wiring RK 50 High Efficiency Condensing Wall Hung Boiler - Heating Only 8 SR 47 M4 brown light-blue 19 18 P 45

RADIANT BRUCIATORI s.p.a. Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU) Tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: tecnico@radiant • Internet: http://www.radiant.it

DATI TECNICI E MISURE NON SONO IMPEGNATIVE. LA DITTA SI RISERVA IL DIRITTO DI EVENTUALI VARIAZIONI SENZA L'OBBLIGO DI PREAVVISO. DECLINIAMO OGNI RESPONSABILITÀ PER EVENTUALI INESATTEZZE CONTENUTE NEL PRESENTE OPUSCOLO, SE DOVUTE AD ERRORI DI STAMPA O DI TRASCRIZIONE. E+OE TUTTI I DIRITTI SONO RISERVATI. NESSUNA PARTE DI QUESTO DOCUMENTO PUÒ ESSERE RIPRODOTTA, MEMORIZZATA IN SISTEMI D’ARCHIVIO, O TRASMESSA IN QUALSIASI FORMA O MEZZO ELETTRONICO, MECCANICO, FOTOCOPIA, REGISTRAZIONE O ALTRI, SENZA LA PREVENTIVA AUTORIZZAZIONE SCRITTA DELLA DITTA.

TA05E011.D0905


Recommended