Fuse SKU 150 amp GANL150 200 amp GANL200 80 amp GANL80 100 amp GANL100 350 amp GANL350 400 amp GANL400 250 amp GANL250 300 amp GANL300 500 amp GANL500 High Power Distribution and Fuse Box Up to 500A Compact and clear DC distribution system for boats and specialist behciles. 3 x ANL fused outputs from 80-500A ability. 5 x 15A continuous outputs with 30A fuses with one 300A fuse supplying that section (all supplied). 1 x 15A 'maintained' output with 30A fuse. Emergency alternator link in the event of the alternator fuse blowing (this prevents the alternator being damaged). Green LEDs to show the circuit is live (LEDs on all the time when battery not isolated, can be switched ‘off’, if preferred, by removing a link). Red LEDs to show when fuse has blown (only on when fuse has blown). Cable guides for the low power cables, plus cable ties to be tightened when wiring complete to keep wires tidy and secure. Most negatives returned to box to enable easy circuit checks. extra aux DC feed position to bypass main feed in event of ancillary equipment requiring a permanent feed even if the main battery bank is isolated, such as alarms or bilge pumps. Link to be removed if green LEDs not wanted, red LEDs will still work in event of fuse failure. Domestic main fuse Domestic Battery Pos Alternator input Regulator protected fuse Inverter fuse Battery neg amps 80-500 amps 80-500 amps 80-500 amps 80-500 + Neg fuse1-30 a fuse1-30 a fuse1-30 a fuse1-30 a fuse1-30 a fuse1-30 a 1 2 3 4 5 6 6 5 4 3 2 1 - aux pos feed + + + + + + + + + - - - - - - 15A aux feed to bypass the main isolation switch to feed items which require a permanent feed for safety reasons such as alarms and Bilge Pumps from alt direct or from split charge device isolation switch 5 x 15A aux outputs 1 x 15A bypass output 6 x 15A neg returns FINISHED UNIT SHOULD LOOK LIKE THIS (clear plastic cover lid removed for better picture) aux output such as inverter/bow thruster up to 500A fuse max or battery charger aux output such as inverter/bow thruster up to 500A fuse max or battery charger 1) Retail market: can modernise your old system and make it safer and easier to find fuses/cables in case of faulty circuitry. Install near domestic to meet modern safety requirements. 2) OEM market: if shall reduce wiring time and improve cable tidiness. Replaces the need for many individual parts to be fitted and connected. Saving both time and money. 3 GANL fuses are required to complete the Distribution box (indicted by the 3 purple lines). They are not supplied with the package. Please refer to the chart below for the correct GANL codes. DC High Powered Fuse Distribution Box Size Weight SKU 300 x 220 x 120 mm 1.5Kg PPD500 3 45
Transcript
Page 1: High Power Distribution and Fuse Box - Kotisivukone · PDF fileHigh Power Distribution and Fuse Box Up to 500A Compact and clear DC distribution system for boats and specialist behciles.

Fuse SKU

150 amp GANL150

200 amp GANL200

80 amp GANL80

100 amp GANL100

350 amp GANL350

400 amp GANL400

250 amp GANL250

300 amp GANL300

500 amp GANL500

High Power Distribution and Fuse BoxUp to 500A

Compact and clear DC distribution system for boats and specialist behciles. 3 x ANL fused outputs from

80-500A ability.5 x 15A continuous outputs with 30A fuses with one 300A fuse supplying that section (all supplied).

1 x 15A 'maintained' output with 30A fuse.

Emergency alternator link in the event of the alternator fuse blowing (this prevents the alternator being damaged).

Green LEDs to show the circuit is live (LEDs on all the time when battery not isolated, can be switched ‘off’, if preferred, by removing a link).

Red LEDs to show w h e n f u s e h a s blown (only on when fuse has blown).

Cable guides for the low power cables, plus cable ties to be tightened when wiring complete to keep wires tidy and secure.

Most negatives returned to box to enable easy circuit checks.

extra aux DC feed position to bypass main feed in event of ancillary equipment requiring a permanent feed even if the main battery bank is isolated, such as alarms or bilge pumps.

Link to be removed if green LEDs not wanted,red LEDs will still work inevent of fuse failure.

Domestic main fuse

DomesticBattery Pos

Alternatorinput

Regulatorprotected fuse

Inverterfuse

Batteryneg

amps80-500

amps80-500

amps80-500

am

ps

80

-50

0

+

Neg

fuse

1-3

0 a

fuse

1-3

0 a

fuse

1-3

0 a

fuse

1-3

0 a

fuse

1-3

0 a

fuse

1-3

0 a

1

2

3

4

5

6

6

5

4

3

2

1

-

auxpos feed

++

++

++

+++ -

-

----

15A aux feed to bypass the main isolation switch

to feed items which require a permanent feed for safety reasons such as alarms and

Bilge Pumps

from alt director from split charge

device

isolationswitch

5 x 15A aux outputs

1 x 15A bypass output

6 x 15A

neg returns

FINISHED UNITSHOULD LOOK LIKE THIS

(clear plastic cover lidremoved for better picture)

aux output such as inverter/bow thrusterup to 500A fuse max or battery charger

aux output such as inverter/bow thrusterup to 500A fuse maxor battery charger

1) Retail market: can modernise your old system and make it safer and easier to find fuses/cables in case of faulty circuitry. Install near domestic to meet modern safety requirements.

2) OEM market: if shall reduce wiring time and improve cable tidiness. Replaces the need for many individual parts to be fitted and connected. Saving both time and money.

3 GANL fuses are required to completethe Distribution box (indicted by the 3 purple lines). They are not supplied with the package. Please refer to the chart below for the correct GANL codes.

DC High Powered Fuse Distribution Box Size Weight SKU300 x 220 x 120 mm 1.5Kg PPD500