+ All Categories
Home > Documents > High-Power Low-Loss Pulsed Bias Tees - Maury Microwave · 1 MARMW.COM / DATA SHEET / 2-002...

High-Power Low-Loss Pulsed Bias Tees - Maury Microwave · 1 MARMW.COM / DATA SHEET / 2-002...

Date post: 10-Jun-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
6
// DECEMBER 2018 High-Power Low-Loss Pulsed Bias Tees DATA SHEET / 2K-002 MODELS: MBT18-7-1000 MBT18-7-5000 MBT18-NMF-5000 MBT18-NFM-5000
Transcript
Page 1: High-Power Low-Loss Pulsed Bias Tees - Maury Microwave · 1 MARMW.COM / DATA SHEET / 2-002 High-Power Low-Loss Pulsed Bias Tees Features > High RF Power Handling > High Breakdown

/ / DECEMBER 2018

High-Power Low-Loss Pulsed Bias TeesDATA S H E E T / 2 K- 0 0 2

MODELS:MBT18-7-1000MBT18-7-5000MBT18-NMF-5000MBT18-NFM-5000

Page 2: High-Power Low-Loss Pulsed Bias Tees - Maury Microwave · 1 MARMW.COM / DATA SHEET / 2-002 High-Power Low-Loss Pulsed Bias Tees Features > High RF Power Handling > High Breakdown

M AU R Y M W. C O M / DATA S H E E T / 2 K- 0 0 21

High-Power Low-Loss Pulsed Bias Tees

Features

> High RF Power Handling

> High Breakdown Voltage

> High Current Handling

> Low Insertion Loss

> Excellent Return Loss

> Pulsing Capable

Model:MBT18-7-1000U.S. Patent No. 9,614,267

Applications

> High Power System Biasing

> High Power Base Station Integration

> Test and Measurement (Load Pull, Pulsed Measurements, General Lab…)

Description

Bias tees are passive RF circuits which provide DC bias to an active device under test. Normally consisting of a capacitor and inductor, bias tees act as diplexers by combining low-frequency (DC) and high frequency (RF) signals onto a common port (RF+DC). In a classic capacitor/inductor design, the capacitor acts as a DC block and prevents DC bias from entering the RF path, while the inductor acts as an RF choke preventing RF energy from entering the DC instrumentation.

Typical applications include providing bias to amplifiers inside of complex systems including base stations and radios; and biasing discrete transistors or packaged devices in test and measurement applications such as DC/pulsed-bias S-parameters, DC/pulsed-IV, DC/pulsed-bias load pull, stability-, robustness-, burn-in-, pre-production- and production-test.

Important characteristics of a bias tee include the frequency range over which the bias tee will function with minimal to no performance degradation, the insertion loss and VSWR (or return loss) over the usable frequency range of the bias tee. Voltages, currents and RF powers are critical both in average/DC/CW and pulsed/peak operations. It is also essential to have bias tees with minimal overshoot of the signals under pulsed bias/pulsed RF conditions.

1 Power and current rating valid under the following condition: Ton = 100us, Duty Cycle = 10%, Iq ≤ 500mA. Different pulse conditions will affect the peak power and current handling.

Specifications

Model

Connector

Frequency Range(GHz)

Insertion Loss (dB)

ReturnLoss (dB) Typical

Max Voltage

(V)

Max DC Current

(A)

RF RatingIsolation

(dB)Typical

DC Resistance

(ohm)Typical

DC BW (MHz)

TypicalRF Port

RF+DC Port

DC Port Typ Max

CWCurrent

(A)

CWPower

(W)

Peak Current

(A) 1

Peak Power (W) 1

MBT18-7-1000

7mmSMA

Female0.35 - 18 0.28 0.6 22 100 1 1 10 2 40 34 0.4 10

MBT18-7-5000

7mmSMA

Female6 - 18 1.1 1.5 15 100 5 5 50 15 250 30 0.4 10

MBT18-NMF-5000

Type N(male)

Type N(female)

SMAFemale

6 - 18 1.1 1.5 15 100 5 5 50 15 250 30 0.4 10

MBT18-NFM-5000

Type N(female)

Type N(male)

SMAFemale

6 - 18 1.1 1.5 15 100 5 5 50 15 250 30 0.4 10

Page 3: High-Power Low-Loss Pulsed Bias Tees - Maury Microwave · 1 MARMW.COM / DATA SHEET / 2-002 High-Power Low-Loss Pulsed Bias Tees Features > High RF Power Handling > High Breakdown

M AU R Y M W. C O M / DATA S H E E T / 2 K- 0 0 2 2

MBT18-7-1000 Typical Insertion Loss - dB

MBT18-7-5000 Typical Insertion Loss - dB

MBT18-7-1000 Typical Return Loss - dB

MBT18-7-5000 Typical Return Loss - dB

Page 4: High-Power Low-Loss Pulsed Bias Tees - Maury Microwave · 1 MARMW.COM / DATA SHEET / 2-002 High-Power Low-Loss Pulsed Bias Tees Features > High RF Power Handling > High Breakdown

M AU R Y M W. C O M / DATA S H E E T / 2 K- 0 0 23

Load pull

Pulsed IV down to 1us

Typical Applications

Page 5: High-Power Low-Loss Pulsed Bias Tees - Maury Microwave · 1 MARMW.COM / DATA SHEET / 2-002 High-Power Low-Loss Pulsed Bias Tees Features > High RF Power Handling > High Breakdown

V I S I T O U R W E B S T O R E

T O L E A R N M O R E A B O U T

O U R P R O D U C T S

w w w . m a u r y m w . c o m____

Page 6: High-Power Low-Loss Pulsed Bias Tees - Maury Microwave · 1 MARMW.COM / DATA SHEET / 2-002 High-Power Low-Loss Pulsed Bias Tees Features > High RF Power Handling > High Breakdown

C O N TAC T U S :W / maurymw.comE / [email protected] / +1-909-987-4715 F / +1-909-987-11122900 Inland Empire BlvdOntario, CA 91764

DATA S H E E T / 2 K- 0 0 2 © 2018 Maury Microwave Corporation. All Rights Reserved.Specifications are subject to change without notice.Maury Microwave is AS9100D & ISO 9001:2015 Certified.


Recommended