+ All Categories
Home > Documents > High Pressure Catalog Number 71A8453 For 400W S51/M169 ... · High Pressure Sodium Lamp Ballast...

High Pressure Catalog Number 71A8453 For 400W S51/M169 ... · High Pressure Sodium Lamp Ballast...

Date post: 09-Jun-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
1
High Pressure Sodium Lamp Ballast Catalog Number 71A8453 For 400W S51/M169 60 Hz CWA Status: Active DIMENSIONS AND DATA 1.30" 6.50" 5.75" B MAX. A 0.7" 0.30" WIDE 2 SLOTS 4 1/4 X 4 3/4 CORE - 2 COIL UNIT 3.90" 4.75" 4.40" 4.40" 4.25" 4 HOLES CLEARED FOR #10 THRU-BOLTS Capacitor: 7C550P24 Capacitance: 55 Dia/Oval Dim: 1.75 Height: 5.15 Temp Rating: 105°C LI5xxHx USE WITH ADVANCE BALLAST FOR (1) 35W-480W METAL HALIDE LAMP MOUNTED IN FIXTURE 105° MAX. CASE TEMP . Red (X1) White (X2) Blue (X3) Ballast to Lamp Distance (BTL) = 2 feet Temp Rating: 105°C Ignitor: LI501-H4 Data is based upon tests performed by Philips Lighting Electronics N.A. in a controlled environment and is representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. PHILIPS LIGHTING ELECTRONICS N.A. 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Tel: 800-322-2086 · Fax: 888-423-1882 · www.philips.com/advance Customer Support/Technical Service: 800-372-3331 · OEM Support: 866-915-5886 INPUT VOLTS 120 208 240 277 480 CIRCUIT TYPE POWER FACTOR (min) REGULATION Line Volts Lamp Watts LINE CURRENT (Amps) Operating............................................................... 3.86 2.20 1.93 1.73 0.96 Open Circuit........................................................... 1.80 1.00 0.90 0.84 0.44 Starting................................................................... 3.45 2.00 1.74 1.54 0.90 UL TEMPERATURE RATINGS Insulation Class Coil Temperature Code C C D D C MIN. AMBIENT STARTING TEMP. NOM. OPEN CIRCUIT VOLTAGE INPUT VOLTAGE AT LAMP DROPOUT................................. 86 150 171 193 335 INPUT WATTS RECOMMENDED FUSE (Amps)............................................. 10 6 5 5 3 CORE and COIL Dimension (A) Dimension (B) Weight (lbs.) Lead Lengths CAPACITOR REQUIREMENT Microfarads Volts (min.) Fault Current Withstand (amps) 60 Hz TEST PROCEDURES (Refer to Philips Lighting Electronics N.A. TEST Procedure for HID Ballasts - Form 127 High Potential Test (Volts) 1 minute 2 seconds Open Circuit Voltage Test (Volts) Short-Circuit Current Test (Amps) Secondary Current Input Current.......................................................... 2.68- 1.54- 1.35- 1.18- 0.67- 4.03 2.30 2.01 1.77 1.00 CWA 98% ±10% ±10% H(180°C) 1029 -40°F or -40°C 195 465 2.65 4.35 16 12" 55.0 240 2000 2500 176-214 6.10-7.40 Wiring Diagram: Fig . M LAMP CAP LAMP COM COM LINE V LINE V LINE V IGNITOR X1 X3 X2 LINE V CAP CAP Typical Ordering Information (please call Philips Lighting Electronics N.A. for suffix availability) Order Suffix Description Revised: 09/23/08
Transcript
Page 1: High Pressure Catalog Number 71A8453 For 400W S51/M169 ... · High Pressure Sodium Lamp Ballast Catalog Number 71A8453 For 400W S51/M169 60 Hz CWA Status: Active DIMENSIONS AND DATA

High PressureSodium

Lamp Ballast

Catalog Number 71A8453For 400W S51/M16960 Hz CWAStatus: Active

DIMENSIONS AND DATA

1.30"

6.50"

5.75"

BMAX.

A

0.7"

0.30" WIDE2 SLOTS

4 1/4 X 4 3/4 CORE - 2 COIL UNIT

3.90"

4.75"

4.40"

4.40"4.25"

4 HOLESCLEAREDFOR #10

THRU-BOLTS

Capacitor: 7C550P24

Capacitance: 55 Dia/Oval Dim: 1.75 Height: 5.15 Temp Rating: 105°C

LI5xxHxUSE WITH ADVANCE BALLAST FOR(1) 35W-480W METAL HALIDE LAMPMOUNTED IN FIXTURE105° MAX. CASE TEMP.

®

Red (X1)White (X2)Blue (X3)

Ballast to Lamp Distance(BTL) = 2 feetTemp Rating: 105°C

Ignitor: LI501-H4

Data is based upon tests performed by Philips Lighting Electronics N.A. in a controlled environment and is representitive of relative performance.Actual performance can vary depending on operating conditions. Specifications are subject to change without notice.

PHILIPS LIGHTING ELECTRONICS N.A.10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018

Tel: 800-322-2086 · Fax: 888-423-1882 · www.philips.com/advanceCustomer Support/Technical Service: 800-372-3331 · OEM Support: 866-915-5886

INPUT VOLTS 120 208 240 277 480CIRCUIT TYPEPOWER FACTOR (min)REGULATION Line Volts Lamp WattsLINE CURRENT (Amps) Operating............................................................... 3.86 2.20 1.93 1.73 0.96 Open Circuit........................................................... 1.80 1.00 0.90 0.84 0.44 Starting................................................................... 3.45 2.00 1.74 1.54 0.90UL TEMPERATURE RATINGS Insulation Class Coil Temperature Code C C D D CMIN. AMBIENT STARTING TEMP.NOM. OPEN CIRCUIT VOLTAGEINPUT VOLTAGE AT LAMP DROPOUT................................. 86 150 171 193 335INPUT WATTSRECOMMENDED FUSE (Amps)............................................. 10 6 5 5 3CORE and COIL Dimension (A) Dimension (B) Weight (lbs.) Lead LengthsCAPACITOR REQUIREMENT Microfarads Volts (min.) Fault Current Withstand (amps)60 Hz TEST PROCEDURES (Refer to Philips Lighting Electronics N.A. TEST Procedure for HID Ballasts - Form 127High Potential Test (Volts)

1 minute 2 secondsOpen Circuit Voltage Test (Volts)Short-Circuit Current Test (Amps) Secondary Current Input Current.......................................................... 2.68- 1.54- 1.35- 1.18- 0.67-

4.03 2.30 2.01 1.77 1.00

CWA98%

±10%

±10%

H(180°C)

1029-40°F or -40°C

195

465

2.654.35

1612"

55.0240

20002500

176-214

6.10-7.40

Wiring Diagram:

Fig . M

LAMP

CAP

LAMP

COM COM

LINE V

LINE V

LINE V

IGNITOR

X1X3

X2

LINE V

CAP CAP

Typical Ordering Information

(please call Philips Lighting Electronics N.A. for suffix availability)

Order Suffix Description

Revised: 09/23/08