Innovave Soluons In Radiaon Detecon and Analysis High Resolution Detectors (HPGE) North American Technical Services Bridging Technology WWW.NATS-USA.COM Innovave Soluons in Radiaon Detecon & Analysis
Transcript

Innovative Solutions In Radiation Detection and Analysis

High Resolution Detectors (HPGE)

North American Technical Services Bridging Technology

WWW.NATS-USA.COM

Innovative Solutions in Radiation Detection & Analysis

U.S. HEAD OFFICE 511 Centerpoint Drive Middletown, CT 06457 U.S.A. Tel: +1-860-635-6820; Fax: +1-860-635-4962 Email: [email protected] www.nats-usa.com

2 Innovative Solutions in Radiation Detection and Analysis

NATS offers a complete range in High Purity Germanium Detectors (HPGE): The High Purity Germanium Spectroscopy Detector is used in the detection and analysis of Gamma-ray of environmental objects in nuclear energetics, products of industry and agriculture, medicine, etc.

This coaxial detector is available in an energy range of 10 keV to 10 MeV and offers high efficiency of radiation detection.

Our range is complete:

10% – 100% relative efficiency HPGe detectors are available Both Liquid Nitrogen & Electrically Cooled Cryostats Portable cryostats and systems Field Radionuclide Identification Systems (LN2 & Electrically Cooled) Specialized Systems for Gaseous and Liquid Flow Systems Deep water Submersible HPGE System Energy range from 10 keV to 10 MeV High efficiency of radiation detection High energy rate up to 200000 MeV/sec Excellent peak symmetry Low background and Ultra – low background materials are available

Complete Signal Processing Electronics and Analysis Software are available

HP(Ge) coaxial detector (p-type & extended range) Preamplifier with cooling input stage Cryostat Dewar vessel Spectrometric MCA - Digital, Analog & Hybrid Systems Emulation and Advanced Gamma Ray Analysis Software

High Resolution Germanium Detectors

3 Innovative Solutions in Radiation Detection and Analysis

All Cryostat Types– LN & Electrically Cooled

4 Innovative Solutions in Radiation Detection & Analysis

All In One HPGE

All-in-one Gamma Spectrometer is designed as one integrated monoblock identical to standard laboratory detection unit with inbuilt preamplifier, however it has inbuilt MCA, HV supply, etc. Fast connect All-in-one Gamma

Spectrometer to the computer using Plug & Play method.

Power supply for all parts of the spectrometer is provided by only one USB cable (USB-2 port). Maximum current less than 300 mA, voltage +5V

The Automated HPGE Spectrometer

is a fully automated systems with a

robotic sample changer enabling the

user to measure up to 40 samples,

without having to interact with the

Automated Spectrometer.

This reliable robotic sample changer

increases the productivity and

reduces the possibility of health risks

HPGE Systems

HPGE– All In One

Automated Gamma Spectrometer with Robotic Sample Changer

5 Innovative Solutions in Radiation Detection & Analysis

Liquid & Gaseous Flow through System using HPGE

HPGE Based Specialized Systems

Flow through HPGE Detection Unit Measures product is mov-

ing inside germanium de-tector

Performs 4π geometry

measurements

Efficiency is dozen times

higher than those com-

pared with Normal HPGE

detectors

Liquid Flow Through HPGE

The spectrometer with shield is designed for defining the composition and activity of radionuclides in liquids and gases in an automated process •Definition of composition and activity of radionuclides in real time mode • Display of current values for specific activity of controlled radionuclides • High registration efficiency • Wide range of measured activities

6 Innovative Solutions in Radiation Detection & Analysis

HAWK: Ultra Light Hand held Germanium Detector Based Identifier

World Smallest Germanium Detector based hand held gamma spectrometry system

Detector, MCA and Gamma analysis software included

Capability to transfer data to base from system

Only one hour cool down time with 20 hours of non stop operation

Includes dose meter and Global Positioning System (GPS)

Supports Efficiency Modeling Software

HAWK-ELECTRIC Electrically Cooled Portable Identification System

HAWK ELECTRIC Sterling Electric Cooled High

Purity Germanium Detector Based hand Held Radionuclide

Identifier 16,000 channels MCA with all

Electronics Imbedded Dose Rate Meter Light Weight Lithium-Ion Long Life Batter 8 Hours cooling Time

HPGE Portable Identification Systems

7 Innovative Solutions in Radiation Detection & Analysis

In-Situ Spectrometer with 360 Rotational View

Deep Water Spectroscopy System with HPGE Detector

Long Duration Submersible Sys-tem

Storage of Gamma

Spectra Package include

Special Software

HPGE Based Specialized Systems

In-Situ Mobile Spectrometer Cart and holder with 360 degree

detector view Optimal sizes and weight for mobile

application Placed in an Hand trolley with Lead

shield set Optional Collimation Set

North American Technical Services, Inc.

511 Centerpoint Drive | Middletown, CT 06457 USA.

Tel: +1-860-635-6820 | Fax: +1-860-635-4962

Email: [email protected] | www.nats-usa.com

WHY NATS?

The Single Source for all Laboratory & Field Instruments For Radiation counting and analysis

Single Source for accumulated knowledge of over

dozen Nuclear Manufacturers & Designers of Radiation Detection Systems

Ability to offer multiple solutions objectively

without bias towards a specific system

Innovative Solutions In Radiation Detection and Analysis


Recommended