High Speed Digital
Transcript
Page 1: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

High Speed Digital

Page 2: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Agenda

• Market Overview

• Product Requirements

• Mid Loss Product Overview (Theta)

• Low Loss Product Overview (FX-2)

• Ultra Low Loss Overview (R&D)

Page 3: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

MARKET OVERVIEW

Page 4: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Macro Trends – Video on Demand

Netflix – Video On Demand

• 26.5 million subscribers (6’ 2012)

• 1 Billion hours of streaming video

in one month (June ‘12)

• Accounts for >20% Broadband

Usage in US

• Uses ~ 41 MB/min

Skype – Video Conferencing

• 31 million subscribers (3’2012)

• 560 million people that have ever

used Skype

• 77% of the global VoIP bandwidth

• Uses ~ 3.4 MB/min

Page 5: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Next Gen switches consume less power, and enable communications from one server to

another server with minimal delays

Macro Trends – Cloud Computing

10/40 GbE Architecture

Enables music

streaming/video streaming

Legacy Architecture

Slower access time

Page 6: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

IP

Infrastructure Computing

Test &

Measurement High Reliability

Market Segmentation

Mobile Infrastructure

upgrades, data center build-

outs, and mobile apps

driving demand in Network

Infrastructure expansion

Demand for Intel

Architecture based servers

driving market, growth in

Unix and Mainframe servers

down

Page 7: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

PRODUCT REQUIREMENTS

Page 8: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Product Requirements

• Electrical Performance – Mid-Loss (df < 0.012)

– Low-Loss (df < 0.007)

– Ultra-Low (df < 0.003)

• Lead-Free Assembly (LFA) – Moisture Level Sensitivity (MSL-1)

(JEDEC STD) Precondition

– 260°C x 10 passes reflow

• CAF Reliability – Wall-to-Wall Space 0.40 - 0.53mm

– Test Conditions: 100V, 65°C/85%RH, 1000hr, 260°C Precondition

Example: .8mm CAF Test Board

Page 9: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Segment Technology Roadmap

Backplanes Line Cards

2009 2012 2015 2009 2012 2015

FR-4

Mid-to-Low

FR-4 to Mid

Mid-Planes Blade Cards

2009 2012 2015 2009 2012 2015

Two leading market segments require mid-loss to ultra-low

loss electrical performance over the next 5 years

Mid-

Loss

Low-

Loss

Ultra

Low

Mid- to

Low

FR4 to

Mid Low-

Loss

Ultra

Low

Mid-

Loss

Low-

Loss

Mid-

Loss Low-

Loss

FR-4

IP Infrastructure

Computing

Page 10: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Electrical Segmentation

0.004

Comp # 4

Electrical Performance (tan δ) 0.010 0.008 0.006 0.001

Rela

tive P

ricin

g

Comp # 3

Comp #2

MCL-FX-2

Comp #6

0.002

RD2

Comp #3 w/

Low DK Glass

Mid Loss Segment Low Loss Segment Ultra Low Loss

Needs: Product Reliability (CAF,

LFA) – HDI Designs

Needs: Same as Mid-Loss +

Electrical Performance of Megtron

6, Broad Product line-up, cost

competitive

Needs: Electrical

Property similar to

PTFE, Broad Product

line-up, suitable for use

in Backplanes and line

cards

Theta™

(MCL-HE-679G)

Page 11: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Comp #4

Rela

tive P

rice

Comp #3

Legacy

Modified

Epoxy

0.78 mm

Wall-to Wall Space

≤ 0.48 mm

Wall-to-Wall Space

Comp #2

Comp #3 w/

Low Dk Glass

Eutectic 220°C Mixed Mode 245°C 260°C Lead-Free

Mid-Loss Lead-Free Assembly

Theta™

(MCL-HE-679G)

Page 12: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Comp #4

Rela

tive P

rice

Comp #3

Legacy

Modified

Epoxy

0.78 mm

Wall-to Wall Space

≤ 0.48 mm

Wall-to-Wall Space

Comp #2 Theta™

(MCL-HE-679G)

Comp #3 w/

Low Dk Glass

Generation 1 Generation 2 Generation 3

0.94 mm

Wall-to Wall Space

Mid-Loss CAF Resistance

Page 13: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Product Line Properties

Properties Units Theta™

(MCL-HE-679G) (MCL-FX-2) Under Development

Material Type Halogen-Free Mid-Loss Low Loss Ultra Low

Loss Lam

Ultra Low

Loss Bond Ply

Dk @ 1GHz 3.90 – 4.10 3.30 - 3.40 3.02 2.94

Df @ 1GHz 0.008 – 0.010 0.002 - 0.003 0.0016 0.003

Tg (TMA) °C 180 – 190 175 – 185 - 170

Tg (DMA) °C 210 – 220 210 - 220

CTEZ (< Tg) ppm/°C 35 - 45 48 - 55 58 50

CTEZ (> Tg) ppm/°C 190 – 220 80 – 130

UL Flammability UL-94 V-0 V-0 V-0 -

IPC4101C Slash Sheet /127, /128/, /130 /102

Mid Loss Low Loss Ultra-Low Loss

Page 14: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Perform

Metric Description

Theta™

(MCL-HE-679G) MCL-FX-2 Under Development

Halogen-Free Mid-

Loss Low Loss

Ultra Low Loss

Laminate

Bond-ply

Low loss

Lead-Free

Assembly

J-STD-020D

(6x260°C)

10x +

0.48mm1

10x +

Min - 0.48mm1 - -

CAF

(Server)

Precon:6x260°C

15V, 600hr

65°C/85%RH

600hr +

Min - 0.48mm1

600hr +

Min - 0.48mm1 - -

CAF

(Network

Infrastructure)

Precon:6x260°C

100V, 1000hr

65°C/85%RH

In Process

Min - 0.40mm1

In Process

Min - 0.40mm1

In Process

Min - 0.40mm1

In Process

Min - 0.40mm1

Interconnect

Stress Test (IST)2

3.2mm, 18L

Precon:6x260°C

1000 Cycles

(20°C – 150°C)

Interconnect

Stress Test

(IST)3

HDI (1+n+1), 18L,

2.l6mm

Precon: 6x260°C

1000 Cycles +

(20°C – 150°C)

100 Cycles

(20°C -190°C)

Highly

Accelerated

Thermal Shock

(HATS)

HDI (3+n+3)

12L, 1.65mm

Precon: 6x260°C

>500 Cycles

(-40°C to +150°C) TBD

Performance by Product Line Mid Loss Low Loss Ultra-Low Loss

Page 15: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Product Line Properties

Property Units Theta™

(MCL-HE-679G) MCL-FX-2 Under Development

Material Type Halogen-Free Mid-Loss Low Loss Ultra Low Loss

Laminate

Ultra Low

Loss BP

Available Cu

Type STD, VLP

STD, VLP,

Profile Free

Rolled Annealed

Electrodeposited,

Resistive Foils

-

Available Cu

Thickness microns 12, 18, 35, 70,105,140 12,18,35,70,105 18, 35 -

Glass Types 1037,1078,1080,3313,

2116, 1501,7629

1037, 1078,1080,

3313,2116 3313, 2116 unreinforced

Spread Glass

Types

1037, 1078, 3313 1037, 1078, 3313 - -

Mid Loss Low Loss Ultra-Low Loss

Page 16: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Glass Glass Type Fabric Count

(warp x fill)/inch

Yarn Diameter

(um)

Thickness

(mm) Products

1037 Spread 70 x 73 4.57 0.028 Theta™, FX-2

106 Non-Spread 56 x 56 5.33 0.033 RO4450F™

1080 Non-Spread 60 x 47 5.33 0.053 RO4450B™,

RO4350B™

1078 Spread 54 x 54 5.33 0.043 Theta™, FX-2

106 (non-spread)

Reduce Fiber Weave Effect

Spread Glass vs. Non-Spread

1080 (non-spread) 1037 (spread) 1078 (spread)

Page 17: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

17

CAF Failure Mode

Dendritic failures in the bond-ply

layers, particularly in the 106

bondply

“Triple Point” failures occur in the

interstitial space between the

individual filaments, likely caused

by a capillary void during

impregnation process

106 glass tightly bound and

difficult to “wet” with resin and

susceptible to capillary voids

Capillary voids trap moisture and

ionic contaminants leading to CAF

formation

Orthogonal View of Glass

bundles

106 Glass Bundles

Glass Filament

Capillary Void

Page 18: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

18

Spread vs Non-Spread

1037 Glass 106 Glass

106 Glass (40X) 1037 Glass (50X)

Glass weaves such as 1037, 1067, 1078 offer advantages over traditional weaves

such as 106 during prepreg impregnation by minimizing the occurrence of capillary

voids

Page 19: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

CAF Test Results (Two Glass Suppliers)

Hollow Fiber in Glass Capillary Void

Glass Supplier “A” Glass Supplier “B”

No Failures!

Page 20: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Rogers Confidential

A-Type Glass Failure Analysis

Orthogonal Hollow-Fiber

Page 21: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

(MCL-HE-679G)

Theta™

Page 22: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

PRODUCT OVERVIEW

Page 23: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Product Overview

Features Benefits

Halogen Free • Meets Future Environmental

Concerns

Broad Range of Thicknesses • Design Flexibility

Low Insertion Loss • Signal Integrity

CAF Resistant • Long Term MLB Reliability

Low Z-Axis CTE • Superior Thermal / Mechanical

Reliability

High Tg / Lead Free Process Compatible • High Temperature Processing

Capability

• Ease of Fabrication

• Meets Environmental Concerns

Page 24: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Product Line Properties

Properties Units Theta™

(MCL-HE-679G) (MCL-FX-2) Under Development

Material Type Halogen-Free Mid-Loss Low Loss Ultra Low

Loss Lam

Ultra Low

Loss Bond Ply

Dk @ 1GHz 3.90 – 4.10 3.30 - 3.40 3.02 2.94

Df @ 1GHz 0.008 – 0.010 0.002 - 0.003 0.0016 0.003

Tg (TMA) °C 180 – 190 175 – 185 - 170

Tg (DMA) °C 210 – 220 210 - 220

CTEZ (< Tg) ppm/°C 35 - 45 48 - 55 58 50

CTEZ (> Tg) ppm/°C 190 – 220 80 – 130

UL Flammability UL-94 V-0 V-0 V-0 -

IPC4101C Slash Sheet /127, /128/, /130 /102

Mid Loss Low Loss Ultra-Low Loss

Page 25: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Transmission Line Characterization

3-Layer Stripline Structure

0.008” Core/0.008” PP

½ oz STD “Shiny” Cu

50 Ω Strip-line

Theta electrical performance comparable to best-in-class mid loss products

#4 Phenolic #3 #2

Page 26: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

-50

-30

-10

0 2 4 6 8 10周波数(GHz)

伝送損失(dB/m) HE-679G+HVLP foil

HE-679 G+RT foil

HE-679G+LP foil

D-4+Std foil

HE-679 G+Std foil

・Loss of HE-679G using VLP or RT is the same as that of D-4 material using Std.

・The reduction of transmission loss is possible by using HVLP.

Transmission Line Characterization vs. Cu Foils

Page 27: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Laminate Electrical Properties

Page 28: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Prepreg/Bondply Electrical Properties

Page 29: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

APPLICATIONS

Page 30: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Tested Applications

• 26-Layer, Server CAF/Pb-Free Reflow Test Vehicle

– 260C, 10x Reflow, CAF Test Vehicle (0.8, 1.0 mm pitch)

• 18-Layer, 3+N+3 IST Coupon (Advanced Technology Product

Designs)

– 260C x 9, 100% pass 1000 cycles @ 150C

• 28-Layer Carrier Class Router OEM Test Vehicle

– Internal 2 oz plane layers, 1mm pitch BGA, 10x 260C Reflow, 2 week

35C/85%RH precondition

• 12-Layer 3+N+3 stacked microvia Design

– Stacked microvias, 4x lamination, blind/buried vias

• 18-Layer 1+N+1 Blind-Buried Microvia Test Vehicle

– 10x 260C reflow, 10x no bake solder floats, 6x260C precon + IST 1000

Cycle @150C + IST 100 Cycle @190C

Page 31: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

26-Layer PCB TV

26-Layer Test Vehicle • 26 Layer PCB

• 0.130” Thick

• 0.010” (0.30mm) Smallest Hole

• 0.8, 1.0 mm Pitch

• 0.019” Web Thickness

• 13:1 Aspect Ratio

Horizontal Section 10x Reflow JEDEC 260C Reflow Profile

26-Layer Server Class Line Card TV

Page 32: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

CAF Coupon

Theta passed all 4 conditions shown above thru 600 hours (for Servers and Storage)

testing at Endicott Interconnect Labs following IBM test requirements

0.48mm

0.53mm

0.68mm

0.74mm

Wall to Wall Spacing

Page 33: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

18-Layer, 3+N+3 IST OEM Coupon (Advanced

Technology Product Designs)

Thermal Analysis Unit Results

TG (TMA) °C 175.4

9x260C IST @ 150C CTF 1000

Page 34: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Carrier Class Router

• 28L, 0.145” Thick

• 2 oz plane layers

• Passed Test parameters – 260̊C, 10x Reflow CSAM

– 35̊C /85%RH 2 week precon

– CAF (1000hr,1.0mm BGA)

– HATS Thermal Analysis Unit Results

TG (TMA) °C 185. 4

CTEZ (TMA), pre-Tg ppm/°C 55.02

CTEZ (TMA), post-Tg ppm/°C 260.4

CTEZ (TMA), 50 – 260C % 2.63%

T260 min >30 min

Page 35: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Eye Brow Crack Test Vehicle

Theta passes 6x solder floats 288C (no preconditioning) without any

evidence of eyebrow cracks, competitive materials fail even with prebakes

Thermal Analysis Unit Results

TG (TMA) °C 175.31

CTEZ (TMA), pre-Tg ppm/°C 57.47

CTEZ (TMA), post-Tg ppm/°C 294.8

CTEZ (TMA), 50 – 260C % 3.18%

T260 min 45.9 min

Page 36: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

3+N+3 Liquid-Liquid Thermal Shock (B)

Thermal Analysis Unit Results

TG (TMA) °C 171.70

CTEZ (TMA), pre-Tg ppm/°C 55.8

CTEZ (TMA), post-Tg ppm/°C 278.6

CTEZ (TMA), 50 – 260C % 3.096%

T260 min 16.33

Page 37: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

1+N+1 Blind-Buried Stacked Microvia TV

Thermal Analysis Unit Results

TG (TMA) °C 174.42

IST @ 150C +

IST @190C CTF 1000+/100+

Lead-Free Assembly

JEDEC STD # of Pass 10X+

Solder Floats (no bake) # of Pass 10X

18-Layer, 0.085” (2.16mm) thickness

• 18 Layers

• Thickness: 0.085” (2.16mm)

• 2 lamination cycles

• Stacked via over Buried Via

• Passed Test Parameters:

– IST coupons (150C + 190C)

– 10x 260C̊ JEDEC LFA Reflow

Page 38: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

FABRICATION

Page 39: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Processing

• Prepreg Shelf-Life/Storage

• Lamination

• Drilling

• Desmear

Page 40: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Precautions in handling

• The shelf life of prepreg is 3 months after the date of

shipping with controlled condition in the moisture barrier

packing (aluminum laminated bag).

• Storage Recommendations: 20+/-5oC(68+/-9oF), <60%RH

Prepreg Shelf-Life/Storage

Page 41: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Lamination Process of HE-679G

• The press cycle should be adjusted in order to attain a Tg of

175oC(347oF) or more (by TMA)

• The product temperature should reach 190oC(374oF). The

minimum requirement should be that the product

temperature exceeds 180oC(356oF) for more than 80

minutes. (Must ; ref. Fig.)

• Product Heating Rate; 2.5-5.0oC /min at 60-130oC

• Apply Full Pressure (2.5-4.0 MPa) before product reaches

110oC

Lamination Cycle

Page 42: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

0

50

100

150

200

0 30 60 90 120 150 180 210 240

Time (min.)

Pro

du

cts

Te

mp

era

ture

(oC

)

0

1

2

3

4

5

6

7

8

9

10

11

12

Pre

ss

ure

(M

Pa

)

Keep more than 180oC(356

oF),

more than 80min. in products

Product pressure: 3MPa(427psi)

Vaccuum Condition: under 4.0mmHg

heating rate: 3-4oC/min.(6-7

oF)

(80oC~130

oC(176-266

oF))

Fig. Recommended press condition

0.4-0.7MP(50-85psi) for 27min.

Press timing: 110-130oC(230-266oF)

190℃

Lamination Process of HE-679G

Apply Full Pressure below 110C̊

Lamination Cycle

Page 43: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Desmearing process

Theta desmear rate is faster than FR-4 in permanganate process

Process Chemicals Temp.

(oC) Duration (Min.)

Swelling Swelling dip Securiganth P 70 2.5 – 5

Etching Concentrate Compact CP 70 5 – 7

Neutralization Securiganth P-500 40 5

Material Sample:

50mm X 50mm (without

copper), N=5

Chemistry:

Rohm and Haas

Desmear

Page 44: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Desmear: Plasma vs. Permanganate

Plasma penetration into

glass bundles

Permanganate results in

virtually no wicking

Page 45: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

FX-2

Page 46: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

PRODUCT OVERVIEW

Page 47: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Product Overview

Features Benefits

High Tg (175 – 185C)/ Lead Free Process

Compatible

High Temperature Processing

Capability

Ease of Fabrication

Meets Environmental Concerns

Low Insertion Loss (50% lower than FR-4)

Dk – 3.4; Df – 0.0026 (1 GHz)

Suitable for applications > 10 Gbps

CAF Resistant Long Term MLB Reliability

Low Z-Axis CTE – 45 ppm/C (<Tg) Superior Thermal / Mechanical

Reliability

Page 48: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Product Line-Up of MCL-FX-2

*This line-up plan is as of Apr.’11. The line-up may be changed for some reasons.

Code nameActual

thicknessEstimated Dk Estimated Df

- (inch) (mm) (inch) 1 GHz 3 GHz 5 GHz 10 GHz 1 GHz 3 GHz 5 GHz 10 GHz

0.05 0.002 1037 x 1 71(69- 73) 0.050 0.0020 3.24 3.24 3.23 3.22 0.0023 0.0028 0.0036 0.0044

Y0.05 0.002 1067 x 1 63(61- 65) 0.050 0.0020 3.43 3.42 3.41 3.39 0.0024 0.0034 0.0042 0.0053

M0.06 0.002 1078 x 1 54(52- 56) 0.057 0.0022 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.06 0.002 1080 x 1 54(52- 56) 0.058 0.0023 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

M0.08 0.003 1078 x 1 64(62- 66) 0.076 0.0030 3.43 3.42 3.41 3.39 0.0024 0.0034 0.0042 0.0053

0.08 0.003 1080 x 1 64(62- 66) 0.078 0.0031 3.43 3.42 3.41 3.39 0.0024 0.0034 0.0042 0.0053

0.1 0.004 3313 x 1 54(52- 56) 0.100 0.0039 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.11 0.004 1037 x 2 71(69- 73) 0.100 0.0039 3.24 3.24 3.23 3.22 0.0023 0.0028 0.0036 0.0044

Y0.11 0.004 1067 x 2 63(61- 65) 0.100 0.0039 3.43 3.42 3.41 3.39 0.0024 0.0034 0.0042 0.0053

0.13 0.005 2116 x 1 54(52- 56) 0.125 0.0049 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.2 0.008 3313 x 2 54(52- 56) 0.200 0.0079 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.26 0.010 2116 x 2 54(52- 56) 0.250 0.0098 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.4 0.016 1501 x 2 54(52- 56) 0.397 0.0156 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.5 0.020 1501 x 2 + x 1 54(52- 56) 0.497 0.0196 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.6 0.024 1501 x 3 54(52- 56) 0.596 0.0235 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.8 0.032 1501 x 4 54(52- 56) 0.794 0.0313 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

1.0 0.040 1501 x 5 54(52- 56) 0.993 0.0391 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

1.2 0.047 1501 x 6 54(52- 56) 1.191 0.0469 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

1.4 0.055 1501 x 7 54(52- 56) 1.390 0.0547 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

1.6 0.063 1501 x 8 54(52- 56) 1.588 0.0625 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

VLP

12 (3/8oz.)

18 (0.5oz.)

35 (1oz.)

profile free

12 (3/8oz.)

18 (0.5oz.)

35 (1oz.)

Copper foil

(um)Construction

RC

(wt%)

Standard

12 (3/8oz.)

18 (0.5oz.)

35 (1oz.)

70 (2oz.)

Laminate Electrical Properties

Page 49: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Product Line-Up of GFA-2 (Prepreg)

**The dielectric thickness after lamination is defined as the thickness of one sheet of prepreg when the

resin flow is within 0%. This value changes according to the press condition and inner-layer pattern.

***This line-up plan is as of Apr.’11. The line-up may be changed for some reasons.

After lam. Thickness Estimated Dk Estimated Df

(mm) (inch) 1 GHz 3 GHz 5 GHz 10 GHz 1 GHz 3 GHz 5 GHz 10 GHz

0.04 #1037 KZNC 69 - 73 0.050 0.0020 3.24 3.24 3.23 3.22 0.0023 0.0027 0.0036 0.0044

#1067 KYMC 61 - 65 0.050 0.0020 3.43 3.42 3.41 3.39 0.0024 0.0034 0.0042 0.0053

#1067 KYUC 71 - 75 0.072 0.0028 3.24 3.24 3.23 3.22 0.0023 0.0027 0.0036 0.0044

0.06 #1080 KUQC 62 - 66 0.078 0.0031 3.43 3.42 3.41 3.39 0.0024 0.0034 0.0042 0.0053

#1080 KUMC 66 - 70 0.089 0.0035 3.35 3.34 3.33 3.31 0.0024 0.0028 0.0041 0.0052

#1080 KUPC 70 - 74 0.104 0.0041 3.24 3.24 3.23 3.22 0.0023 0.0027 0.0036 0.0044

#1078 KRQC 62 - 66 0.076 0.0030 3.43 3.42 3.41 3.39 0.0024 0.0034 0.0042 0.0053

#1078 KRMC 66 - 70 0.087 0.0034 3.35 3.34 3.33 3.31 0.0024 0.0028 0.0041 0.0052

0.08 #3313 KGHB 54 - 58 0.106 0.0042 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

#3313 KGKB 56 - 60 0.112 0.0044 3.43 3.43 3.42 3.41 0.0025 0.0032 0.0043 0.0054

0.1 #2116 KAGB 52 - 56 0.125 0.0049 3.44 3.43 3.42 3.41 0.0026 0.0036 0.0045 0.0055

0.15 #1501 KQGB 50 - 54 0.188 0.0074 3.48 3.47 3.46 3.45 0.0029 0.0040 0.0050 0.0061

RC

(wt%)Glass Style

Nominal

thickness

(mm)

Prepreg

Type name

Prepreg Electrical Properties

Page 50: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

-60

-40

-20

0

0 5 10 15 20

Frequency (GHz)

Tra

nsm

isson L

oss (

dB

/m

)

FX-2+HVLP foil

FX-2+Std foil

FX-2+RT foil

FX-2+LP foil

D-6+HVLP foil

FX-2 Transmission Loss (Various copper)

・Loss of FX-2 using VLP or RT is the same as that of D-6 material using HVLP.

・The reduction of transmission loss is possible by using HVLP.

Transmission Line Characterization vs. Cu Foils

Page 51: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

SPP method

Evaluation Board

Construction

High RC (S3)

1

2

3

4

5

6

7

8

Core 1x1078, 72% resin

1/2oz Cu (PF)

Fill 1x1078, 72% resin

Core 1x2116 54% resin

Fill 1x2116 54% resin

1/2oz Cu (PF)

1/2oz Cu (VLP)

1/2oz Cu (VLP)

1/2oz Cu (VLP)

1/2oz Cu (VLP)

Fill 1x2116 54% resin

1/2oz Cu (STD)

Fill

1/2oz Cu (STD)

1x2116 54% resin

Core 1x2116 54% resin

1

2

3

4

5

6

7

8

Core 1x1078, 72% resin

1/2oz Cu (PF)

Fill 1x1078, 72% resin

Core 1x2116 54% resin

Fill 1x2116 54% resin

1/2oz Cu (PF)

1/2oz Cu (VLP)

1/2oz Cu (VLP)

1/2oz Cu (VLP)

1/2oz Cu (VLP)

Fill 1x2116 54% resin

1/2oz Cu (STD)

Fill

1/2oz Cu (STD)

1x2116 54% resin

Core 1x2116 54% resin

Low RC (S6)

SMASPP2z Test Vehicle

3cm

9.8cm

Evaluation Line: Single end strip line

Pulse wave analysis Equipment

Short Pulse Propagation (SPP) Method, Dk/Df

Page 52: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

SPP Extracted Dk/Df

Short Pulse Propagation (SPP) Method, Dk/Df FX-2

Block Frequency Dk Df

1GHz 3.118 0.0050

3GHz 3.106 0.0053

10GHz 3.095 0.0053

20GHz 3.087 0.0064

1GHz 3.482 0.0054

3GHz 3.469 0.0058

10GHz 3.454 0.0062

20GHz 3.444 0.0074

HE-679GBlock Frequency Dk Df

1GHz 3.675 0.0148

3GHz 3.634 0.0161

10GHz 3.588 0.0165

20GHz 3.562 0.0169

1GHz 3.950 0.0115

3GHz 3.917 0.0124

10GHz 3.880 0.0125

20GHz 3.858 0.0134

S3

(Resin rich)

S6

(Resin poor)

S3

(Resin rich)

S6

(Resin poor)

Page 53: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Layer counts : 26 layer board

Total thickness : 4.1mm

Precondition:

E-0.5/110 C-24/85/85%RH

Reflow

260degC X 10 times

No blister & No delamination

observed

Dia.0.25mm Dia.0.30mm

Heat resistance of high layer count board

After reflow 260degC 10sec x 6 times

26-Layer Lead-Free TV

Page 54: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

CAF Coupon

FX-2 passed all 4 conditions shown above thru 600 hours (for Servers and Storage)

testing following IBM test requirements

0.48mm

0.53mm

0.68mm

0.74mm

Wall to Wall Spacing

Page 55: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Thermal Analysis

Test Description Unit Method Results

FX-2 Cycle 1 Cycle 2

TG (TMA) °C IPC TM 650 2.4.41 191.15 193.7

CTEZ (TMA), pre-Tg ppm/°C IPC TM 650 2.4.41 73.26 72.21

CTEZ (TMA), post-Tg ppm/°C IPC TM 650 2.4.41 130.6 127.8

CTEZ (TMA), 50 – 260C % IPC TM 650 2.4.41 2.177 2.126

T260 (with external copper) min IPC TM 650 2.4.24.1 Pass Pass

T288 (with external copper) min IPC TM 650 2.4.24.1 12.39 10.64

Page 56: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

Ultra-Low Loss High Speed Digital

Material System

Page 57: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

12/5/2012 Rogers Proprietary 57

Emerging Market Needs • We are seeing an emerging market opportunity for

interconnects at speeds of 25 Gb/s and higher with

interconnect lengths up to 30” – High Speed Computing

– SANS

– IP Routers / Switches

– ATE

– Optical Networks

– Backplanes and large system cards

Page 58: High Speed Digital · 2012-12-09 · Reduce Fiber Weave Effect Spread Glass vs. Non-Spread 1037 (spread) 1078 (spread)1080 (non-spread) 17 CAF Failure Mode Dendritic failures in the

12/5/2012 Rogers Proprietary 58

Emerging Market Needs

• No existing material system available today meets all needs - Electrical modeling indicates a need for

- Dk<3.5

- Df<.002

- Low surface roughness copper (=/< .5 um Rq)

- Very few Choices meet above criteria

- In Addition; Designs typified by need for

- High layer counts

- Dimensional stability

- Low Z-axis CTE for reliability on high aspect ratio holes

- Ability to withstand lead-free solder reflow (high Td)


Recommended