Page 1: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Hillmed

HM-Cardio MD

Page 2: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Multi-Parameter Resting 12-Lead

PC Based Resting 12-Lead ECG

Notebook Based Resting 12-Lead

PDA / Smart Phone Resting 12-Lead

Ambulance to ER Resting 12-Lead

Multi-Hour 12-Lead Monitoring

Blue Tooth Transmitter @ 100 Meters

Includes Simple Stress Test Program

4.0 Standard or Premier Programs

Optional 5.0 Stress Test Program

Page 3: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Multi-Parameter Resting 12-Lead

Interpretation / Suggestion

Serial Comparison

SAECG Late Potentials

Vectorcardiography

Hi-Frequency 12-Lead Analysis

QT, QTc, and QTd Analysis

Axis Deviation

FrequencyCardioGram

Page-Scan Full-Disclosure Review

Page 4: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Operational Options

Standard ECG

Quick ECG

Multi-Hour ECG Monitoring

Simple Stress Test

Page 5: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Quick ECG

ECG Acquisition for a few seconds. ECG, Time, and Heart Rate are

displayed. Upon display of clean ECG,

perform a mouse click.

ECG is immediately analyzed for interval measurements.

Upon verification of correct intervals, perform a mouse click

12-Lead test is completed.

Page 6: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Quick ECG

Page 7: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

HM-CARDIO MD 12-Lead ECG The 4.0 Standard program

includes the 12-Lead ECG program, plus the Interpretation program.

The Interpretation program includes the Axis Deviation analysis.

The quick visual edit of the vertical marker locations for:

* Beginning of P-wave * End of P-wave * Beginning of Q * End of S * Beginning of T * End of T provides the correct

foundation for the Interpretation program.

HL7 and Dicom outputs available.

Page 8: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

The 4.0 Premier program includes:

* 12-Lead ECG * Interpretation * Simple Stress Test * SAECG Late Potentials * QTc & QTd * FrequencyCardioGram (FCG) * Multi-Hour ECG with HRV * Hi-Frequency ECG * VectorCardioGraphy (VCG)

ECG Acquisition is with: * Blue Tooth Transmitter (100

meters)

* USB Hi-Res Acquisition Box * HM-Holter MINI-Recorder

A low-cost and simple Holter CS-6A program is an optional add-on to the Winnervision program.

HM-CARDIO MD 12-Lead ECG

Page 9: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

PDA / Mobile Phone 12-Lead ECG

Blue Tooth sends 12-Lead ECG to PDA or Smart Phone (PSP), with the Resting 12- Lead software.

PSP displays, analyzes, stores, and has printer outputs for the 12-Lead.

ECGs can be collected for a large number of patients, and then transferred to the 12-Lead PC station in the hospital’s EKG Lab.

12-Lead ECG strips can be e-mailed to PCs or other physicians. This makes for a pocket ECG system that the physician can take into any out-of-the-office environment.

Ideal for sports medicine and Ambulance monitoring environments.

Page 10: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Ambulance Resting 12-Lead ECG

Ambulance to hospital ECG for immediate treatment of cardiac patient emergencies.

Blue Tooth ECG to Smart Phone.

Smart Phone transmits 12-Lead ECG on demand or at pre-set intervals.

Ambulance personnel receive verification for life-saving interventions.

Upon arrival at hospital, 100% of Ambulance 12-Lead ECG is transferred to CS-12 for review in real-time mode and Holter mode.

ECG continues in Emergency Room.

Page 11: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Multi-Hour ECG Monitoring 12-Lead Hospital Patient

Monitoring with Blue Tooth.

Single patient ECG station.

Analysis of: Arrhythmias ST QTc and QTd Heart Rate Variability

Patient can be mobile with Blue Tooth Transmitter.

Sample rate of 4,096 with 12-Bit resolution.

Page 12: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Simple Stress Test

Included in 4.0 Premier.

Displays: Heart Rate Target Heart Rate % of Target Heart Rate Delta Heart Rate

Change Elapsed Time

The reference beginning ECG is shown at the far left side for each ECG Lead.

ECG prints available at all times during Stress Test.

Stress Test reviewed in Page Scan mode.

Page 13: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Resting 12-Lead with Simple Holter

Resting 12-Lead security key is also programmed with the simple CS-6a Holter program.

For the non-cardiologist market.

CS-6a consists of a 24-hour mini-Holter recorder (300-4) and a Holter software program.

The 300-4 can be a 3-Lead or 12-Lead recording for 24-hours.

CS-6a is a Page-Scan and Full Disclosure program. There is no Template editing, but the program includes the Category Event displays of ECG abnormalities that can be edited,

Page 14: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

HM-CARDIO MD

HM-CARDIO MD program includes: SAECG Late Potentials Vectorcardiography Hi-Frequency ECG QTc

SAECG program allows for manual edit.

Vectorcardiography also includes the Timed VCG which allows the VCG Loops to be directly compared with the XYZ ECG.

SAECG

VCG

VectorCardioGraphy

SAECG Late Potentials

Page 15: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.
Page 16: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

FCG CADgram

FrequencyCArdioGram

The FCG CADgram detects and locates blockages in the coronary arteries.

It does not require any exercise protocol. The Resting 12-Lead is the preferred environment for the FCG test.

A positive FCG CADgram is a strong indication for an exercise stress test.

Page 17: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Hi-Frequency ECG

The Hi-Frequency ECG is to closely examine the notches and slurs of the expanded QRS.

Mini ECG Pocket Card

The program produces a ECG patient information card that can be carried in the patient’s wallet or purse.

Mini ECG Card for Patient Wallet or Purse

High Resolution QRS ECG

Page 18: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Holter Add-On to HM-CARDIO MD

Holter Full Disclosure

Page 19: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Holter Add-On toHM-CARDIO MD

Uses 300-4 device.

For the non-cardiologist market.

This is a Page-Scan and Full Disclosure Holter ECG system with ECG print-outs.

The Category ECG Events of Pause, ST, VE, V-Runs, SVE, Min. HR, Max. HR, etc. are displayed for ECG acceptance or rejection.

PDF e-mailing of ECG data is included.

Database storage and retrieval is included.

Sixteen (16) Ventricular Ectopic ECG’s

Instant E-Mail of Holter Report Pages

Page 20: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Blue-tooth ECG transmitter and receiverHM-CARDIO MD BLUE TOOTH Method of transmitting and receiving:

Digital; Transmitting and receiving frequency:

2.4G Hz; Working distance: Model: 15m visible; Transmitter voltage: DC 6.0V; Receiver voltage: DC 5.0V.

Blue-tooth ECG transmitter and receiver

Sample rate: <=4096Hz; Sample resolution: 12bit; Lead: 12-lead standard ECG; Input circuit current: ≤ 0.1μA; Input impedance: ≥ 5 MΩ; Noise electric level: ≤ 15μVp-p; Standard sensitivity: 10mm/mV ±5%; Anti-polarization voltage: if add ±300mV DC polarization

voltage, the change of sensitivity is not more than ±5%; CMRR: ≥ 60 dB; Frequency response: 0.5 -150 Hz ( +0.4 dB, -3.0 dB ) ; Lower frequency feature: time constant is not less than

3.2s; Stability: when the power supply transient change is

10%, the baseline wondering is not more than ±5%. The sensitivity error is not more than ±5%.50Hz filter: ≥ 20dB;

Equipment safety type: the wired ECG acquisition box is class II, type-BF; the blue-tooth ECG transmitter is type-BF with internal power; the blue-tooth ECG receiver is class II, type-B;

Working environment: Temperature: 10 - 30℃, Relative humidity: ≤ 70%, Atmospheric pressure: 860 - 1060hPa;

Storage environment: Temperature: -20 - 55℃, Relative humidity: ≤ 93%, Atmospheric pressure: 500 - 1060hPa.

Page 21: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

Bluetooth Transmitter (front)

Bluetooth Receiver

Bluetooth Transmitter (back)

Patient Cables

Page 22: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

1. Connect the Bluetooth receiver to the USB port of the computer.

Page 23: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

2. Connect the patient cable to the Bluetooth transmitter.

3. Insert the batteries into the Bluetooth transmitter.

Page 24: Hillmed HM-Cardio MD.  PC Based Resting 12-Lead ECG  Notebook Based Resting 12-Lead  PDA / Smart Phone Resting 12-Lead  Ambulance to ER Resting 12-Lead.

4. Hold the power switch at the top of the Bluetooth transmitter for 3 seconds. The LED lights on the front will light up to indicate it is on and active.