HISENSE CENTRAL AIR CONDITIONING HCAC-BR-HISR01 All rights reserved by Qingdao Hisense HVAC Equipment Co.,Ltd. Design and specifications are subject to change without notice. Pictures and diagrams are for reference only and are subject to change without notice. http://www.hisense-vrf.com [email protected] @HisenseVRFGlobal Hisense VRF Hisense VRF Qingdao Hisense HVAC Equipment Co.,Ltd. Hisense Tower, Qingdao, China
Transcript
Page 1: HISENSE CENTRAL AIR CONDITIONING

HISENSE CENTRAL AIR CONDITIONING

HCAC-BR-HISR01

All rights reserved by Qingdao Hisense HVAC Equipment Co.,Ltd.

Design and specifications are subject to change without notice. Pictures and diagrams are for reference only and are subject to change without notice.

http://www.hisense-vrf.com [email protected] @HisenseVRFGlobal Hisense VRF Hisense VRF

Qingdao Hisense HVAC Equipment Co.,Ltd.

Hisense Tower, Qingdao, China

Page 2: HISENSE CENTRAL AIR CONDITIONING

15

INDOORUNIT

19

OPTIONALPART

20

CONTROLLER

01

PRODUCTFEATURES

11

OUTDOORUNIT

CONTENTS

Page 3: HISENSE CENTRAL AIR CONDITIONING

Strong Heart for Residential Use Brazing Free Refrigerant Piping

01 02

High-efficiency full DC inverter compressor is used for products of Hisense

Hi-Smart H Series, whose motor is more efficient and energy-saving. The com-

pressor has a special anti-vibration structure design, ensuring stable operation,

small vibration and a long service life. The design promotes the high reliability and

low noise of outdoor unit, greatly improving user experience.

High-efficiency DC Inverter Compressor

Fully Lubrication

More Efficient

Fast Start

More Stable

Hisense new refrigerant piping connection with flare-nut branch pipe breaks through the common way of connecting refrigerant

copper pipes by replacing brazing processes with simple and safe flare nuts connections.

Convenient and simple installation

Saving installation time and cost

Preventing leakages due to poor brazing

No hot work permit application is required

Enhanced safety with no fire-involving process

Page 4: HISENSE CENTRAL AIR CONDITIONING

Anti-corrosion Solutions

03 04

High Level Quality Guarantee

All the components mandatorily require to pass the following stringent certification tests and batch inspections our factory:

The lifespan of electrical parts under normal temperature and high temperature

Hisense Hi-Black fin is applied for protection from various corrosive environments such as

seasides with high salt contamination and industrial cities filled with fumes from factories.

Hi-Black fin is coated with epoxy resin specially for corrosive resistance, while the conven-

tional fin is only coated with acrylic resins. The thickness of epoxy resin is 1.5 times more

than acrylic resin, and its anti-corrosion properties are 3 times better than acrylic resin.

What's more, there is a hydrophilic film covered the epoxy resin, keeping water from accu-

mulating on the fins, minimizing moisture buildup. These improvements can greatly prolong

the unit's lifespan and lower the maintenance costs.

Hi-Black Fin

Conventional Fin Hi-Black Fin

Note

Customized by needs, please contact the local engineer.

20,000 times

The lifespan of four-way valve The lifespan of pressure switch The lifespan of magnetic valve

10,00,000 times

The lifespan of AC contactor

200 times

The lifespan of motor stalling

10 years

The lifespan of motor bearing

100,000 times 100,000 times

Morethan

High-temperature test 85℃×500 hours

Low-temperature test -30℃×500 hours

Salt-spray test 35℃, 5% NaCl, 240 hours

High and low temperature interaction test

each lasts 2 hours, and continuous switched for 500 times

Vibration test

XYZ direction 2~55 Hz, 2h for each direction

The internal stress test

80%Acetic acid glacial, 30min; 15%Ammonia water, 30min

Page 5: HISENSE CENTRAL AIR CONDITIONING

05 06

Hisense VRF indoor unit equipped with AirPure kit can release lots of negative ions, about 20 million pcs/cc. These

negative ions are carried throughout the room with air-conditioned air flow whereby obtaining air conditioning and

air purification simultaneously.

Anti-Bacteria and Anti-Virus

Anti-moldFormaldehyde Removal

Odor Removal PM2.5 Purification Anti-allergen

-

Note

Ceiling Ducted and the new Wall Mounted which will be launched at the end of 2020 can be

equipped with the AirPure kit (optional).

Integrated design of fresh air and exhaust air, built-in high-efficiency heat

recovery core, during the introduction of fresh air, it can effectively exhaust

PM2.5 particles, formaldehyde, pollen particles, cigarette particles, carbon

dioxide and others simultaneously.

Keep the indoor air fresh and clean.

Heat Recovery Ventilator, take care of your every breath

AirPure Fresh Air

All fresh air IDU, focus on IAQ

When the temperature difference between indoor and outdoor is large, the

outdoor fresh air is accurately treated according to the indoor temperature, After

heating or cooling to near room temperature, it is introduced into the room;

When the temperature difference between indoor and outdoor is small, the fresh

air is directly introduced into the room after filtration without temperature treat-

ment, to save energy and create a green and healthy environment.

Page 6: HISENSE CENTRAL AIR CONDITIONING

3D Air-Flow Auto-Dehumidification

07 08

Intelligent Auto-dehumidification, maintain the comfortable and refreshing environment

3D Air Flow, to feel the customized air

Hisense 3D air flow, with innovative three motor design, realizes independent and

combined control of vertical and horizontal louver. Users can customize the air supply

angle according to their needs. The wide and flexible air supply angle can meet the full

coverage of the comfortable air flow of the room.

The indoor unit is equipped with humidity sensor, which can automatically detect the room humidity.

It can be used with multi-function controller, when the room humidity exceed the set value, the

dehumidification instructions can be conveyed to automatic adjust room humidity. There is no

worry about mildew anymore and it can always ensure the home clean.

Page 7: HISENSE CENTRAL AIR CONDITIONING

Note

The above noise values are measured in an anechoic chamber so that reflected sound

should be taken into consideration during actual operation.

Hisense indoor units sound pressure level can be as low as 21dB(A).

Also, the Night Mode reduces sound pressure levels by 30% routinely

with flexible time intervals to meet different needs.

Professional Noise Control

09 10

Smart & Precise Temperature Control

To maintain the ideal temperature of the human active area inside of room, Two Temperature Sensor Control Technolo-

gy is integrated into the unit whereby the controller, and return section consist of built-in temperature sensors to send

real-time signals to the unit for a more precise supplying temperature.

Built-in temperature sensor

Quiet Space Precise Temperature Control

Quiet Operation Night Mode

Page 8: HISENSE CENTRAL AIR CONDITIONING

OUTDOORUNIT

11 12

Model(HP) 43 55

Model AVW-28HJFH

AC 1Φ, 220-240V/50Hz AC3 Φ, 380-415V/50Hz

AVW-34HJFH AVW-43HKFHAVW-43HJFH

Power Supply

Nominal Capacity

NominalCapacity

kW

kW

-

kW/kW

kW/kW

-

-

kW

kW

m3 /min

mm

mm

kg

kg

mm(in.)

mm(in.)

Air Flow Rate

Out Dimension(H×W×D)

Packing Dimension(H×W×D)

Net Weight

Gross Weight

Max. number of connectable IDU

Compressor Type

dB(A )

℃ DB

℃ WB

Cooling

Heating

Liquid Line

Gas Line

PowerConsumption

PowerConsumption

EER

COP

Cooling Operation

HeatingOperation

Sound Pressure Level(Cooling/Heating)

RefrigerantPiping

OperationRange

8.0

1.93

4.15

9.5

2.37

4.01

46.5

800×950×370

930×1025×460

65

72

Φ9.53(3/8)

Φ15.88(5/8)

5

50/52

10.0

2.34

4.27

11.2

3.01

3.72

69.0

800×950×370

930×1025×460

73

81

Φ9.53(3/8)

Φ15.88(5/8)

6

53/55

12.5

2.98

4.19

14.0

4.15

3.37

78.0

800×950×370

930×1025×460

78

86

Φ9.53(3/8)

Φ15.88(5/8)

8

54/57

12.5

3.81

3.28

14.0

3.68

3.80

75.0

800×950×370

930×1025×460

84

96

Φ9.53(3/8)

Φ15.88(5/8)

8

55/57

-5~46

-15~15.5

DC Inverter

-5~46

-15~15.5

DC Inverter

Notes:Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length : 7.5m, pipe height difference: 0m

Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m

Page 9: HISENSE CENTRAL AIR CONDITIONING

13 14

Model(HP) 10 12

Model

AC 3Φ, 380-415V/50/60Hz

AVW-114HKFH1AVW-96HKFH1

Power Supply

Nominal Capacity

NominalCapacity

kW

kW

-

kW/kW

kW/kW

-

-

kW

kW

m3 /min

mm

mm

kg

kg

mm(in.)

mm(in.)

Air Flow Rate

Out Dimension(H×W×D)

Packing Dimension(H×W×D)

Net Weight

Gross Weight

Max. number of connectable IDU

Compressor Type

dB(A )

℃ DB

℃ WB

Cooling

Heating

Liquid Line

Gas Line

PowerConsumption

PowerConsumption

EER

COP

Cooling Operation

HeatingOperation

Sound Pressure Level(Cooling/Heating)

RefrigerantPiping

OperationRange

28

7.75

3.61

31.5

7.00

4.50

150

1650×1100×390

1806×1185×530

145

162

Φ12.7(1/2)

Φ22.2(7/8)

17

58/59

33.5

10.30

3.25

37.5

10.00

3.75

163

1650×1100×390

1806×1185×530

172

189

Φ12.7(1/2)

Φ25.4(1/1)

19

59/60

-5~50*1

-20~15.5

DC Inverter

Notes:Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length : 7.5m, pipe height difference: 0m

Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m

Model(HP) 87 9

Model AVW-68HKFH1

AC 3Φ, 380-415V/50/60Hz

AVW-76HKFH1 AVW-84HKFH1

Power Supply

Nominal Capacity

NominalCapacity

kW

kW

-

kW/kW

kW/kW

-

-

kW

kW

m3 /min

mm

mm

kg

kg

mm(in.)

mm(in.)

Air Flow Rate

Out Dimension(H×W×D)

Packing Dimension(H×W×D)

Net Weight

Gross Weight

Max. number of connectable IDU

Compressor Type

dB(A )

℃ DB

℃ WB

Cooling

Heating

Liquid Line

Gas Line

PowerConsumption

PowerConsumption

EER

COP

Cooling Operation

HeatingOperation

Sound Pressure Level(Cooling/Heating)

RefrigerantPiping

OperationRange

20

5.63

3.55

22

5.09

4.32

127

1380×950×370

1531×1070×515

123

137

Φ9.53(3/8)

Φ19.05(3/4)

15

57/58

22.4

6.37

3.52

25

5.84

4.28

127

1380×950×370

1531×1070×515

124

138

Φ9.53(3/8)

Φ19.05(3/4)

15

57/58

24.5

7.78

3.15

26

6.84

3.80

127

1380×950×370

1531×1070×515

125

139

Φ9.53(3/8)

Φ19.05(3/4)

15

57/58

-5~50*1

-20~15.5

DC Inverter

Notes:Rated cooling capacity and rated heating capacity are tested in the following conditions:

Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length : 7.5m, pipe height difference: 0m

Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m

Page 10: HISENSE CENTRAL AIR CONDITIONING

INDOORUNIT

15 16

Ceiling Ducted Type(AC Low Height)

Model

Capacity

Power Input

Sound Pressure dB(A)

Airflow Rate

External Static Pressure

m3/min

Pa

Heating

Piping

Weight

Dimensions

kW

Btu/h

kW

Btu/h

W

W

-

mm

inch

mm

inch

mm

kg

kg

mm

mm

mm

mm

mm

mm

Cooling

Heating

Cooling

Connection Type

Liquid

Gas

Net Weight

Gross Weight

External

Packaging

Condensate Drain

Power Supply

I.D.32

H

W

D

H

W

D

Flare-nut Connection(with Flare Nuts)

AC 1Φ, 220V~240V/50Hz

Notes: The nominal cooling capacity and heating capacity are based on the following conditions:

Cooling Operation Conditions

Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB)

Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)

Piping Length: 7.5 Meters Piping Lift: 0 Meter

Heating Operation Conditions

Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).

Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)

The sound pressure level is based on the following conditions: 1.5m beneath the unit.

The above data was measured in an anechoic chamber so that the reflected sound should be

taken into consideration in the field.

2.1.

1.7

5,800

1.9

6,500

50

50

29/24/22

7/5.5/4.7

10(30)

Φ 6.35

1/4

Φ 12.7

1/2

16

19

192

700

447

270

925

574

2.2

7,500

2.5

8,500

50

50

29/24/22

7/5.5/4.7

10(30)

Φ 6.35

1/4

Φ 12.7

1/2

16

19

192

700

447

270

925

574

2.8

9,600

3.2

11,300

70

70

35/25/23

9/5.7/4.8

10(30)

Φ 6.35

1/4

Φ 12.7

1/2

17

20

192

700

447

270

925

574

3.6

12,300

4.0

13,600

70

70

35/25/23

9/5.7/4.8

10(30)

Φ 6.35

1/4

Φ 12.7

1/2

17

20

192

700

447

270

925

574

4.5

15,300

5.0

17,100

80

80

36/25/23

12/6.3/5.5

10(30)

Φ 6.35

1/4

Φ 12.7

1/2

21

24

192

910

447

270

1136

574

5.0

17,100

5.6

19,100

80

80

36/25/23

12/6.3/5.5

10(30)

Φ 6.35

1/4

Φ 12.7

1/2

21

24

192

910

447

270

1136

574

5.6

19,100

6.3

21,500

100

100

35/25/23

13.5/8/7.7

10(30)

Φ 6.35

1/4

Φ 15.88

5/8

25

29

192

1180

447

270

1406

574

6.3

21,500

7.1

24,200

120

120

39/26/25

18/9.3/8.7

10(30)

Φ 9.53

3/8

Φ 15.88

5/8

26

29

192

1180

447

270

1406

574

7.1

24,200

8.0

27,300

120

120

39/26/25

18/9.3/8.7

10(30)

Φ 9.53

3/8

Φ 15.88

5/8

26

29

192

1180

447

270

1406

574

AVE-05

HCFRL

AVE-07

HCFRL

AVE-09

HCFRL

AVE-12

HCFRL

AVE-15

HCFRL

AVE-17

HCFRL

AVE-19

HCFRL

AVE-22

HCFRL

AVE-24

HCFRL

Page 11: HISENSE CENTRAL AIR CONDITIONING

17 18

Ceiling Ducted Type (High Static Pressure)

3. When bottom air inlet is adopted, the sound pressure will increase according to factors

such as installation mode and the room structure.

2. The sound pressure level is based on the following conditions: 1.5m beneath the unit.

With discharge duct (2.0m) and return duct(1.0m)

The above data was measured in an anechoic chamber so that the reflected sound

should be taken into consideration in the field.

1.The nominal cooling capacity and heating capacity are based on the following conditions:

Cooling Operation Conditions

Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB)

Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)

Piping Length: 7.5 Meters Piping Lift: 0 Meter

Heating Operation Conditions

Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).

Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)

Notes:

Capacity

Power Input

Sound

Pressure

Heating

Piping

Weight

Dimensions

Cooling

Heating

Cooling

Connection Type

Liquid

Gas

Net Weight

Gross Weight

External

Packaging

Condensate Drain

H

W

D

H

W

D

Flare-nut Connection(with Flare Nuts)

External

Static Pressure

kW

Btu/h

kW

Btu/h

kW

kW

dB(A)

dB(A)

dB(A)

m3/min

Pa

Pa

-

mm

inch

mm

inch

mm

kg

kg

mm

mm

mm

mm

mm

mm

2.2

7500

2.5

8500

0.10

0.10

32/27/25

33/28/24

37/33/28

9/7/6

50(80)

80(105)

Φ6.35

1/4

Φ12.7

1/2

25(24*1)

31(30*1)

270

650+75

720

385

895

870

2.8

9600

3.2

10900

0.10

0.10

32/27/25

33/28/24

37/33/28

9/7/6

50(80)

80(105)

Φ6.35

1/4

Φ12.7

1/2

25(24*1)

31(30*1)

270

650+75

720

385

895

870

3.6

12300

4.0

13700

0.13

0.13

35/32/26

37/34/29

40/38/33

12/10/8.5

50(80)

90(115)

Φ6.35

1/4

Φ12.7

1/2

25(24*1)

31(30*1)

270

650+75

720

385

895

870

4.5

15400

5.0

17100

0.13

0.13

35/32/26

37/34/29

40/38/33

12/10/8.5

50(80)

90(115)

Φ6.35

1/4

Φ12.7

1/2

25(24*1)

31(30*1)

270

650+75

720

385

895

870

5.6

19100

6.3

21600

0.14

0.14

36/35/30

37/35/29

42/40/34

15/13/10

50(80)

90(115)

Φ 6.35

1/4

Φ 15.88

5/8

30(31*1)

36(38*1)

270

900+75

720

385

1140

870

6.3

21600

7.1

24200

0.19

0.19

39/32/25

39/32/25

43/37/30

19/14/10

50(80)

90(115)

Φ9.53

3/8

Φ15.88

5/8

30(31*1)

37(38*1)

270

900+75

720

385

1140

870

7.1

24200

8.0

27400

0.19

0.19

39/32/25

39/32/25

43/37/30

19/14/10

50(80)

90(115)

Φ 9.53

3/8

Φ 15.88

5/8

30(31*1)

37(38*1)

270

900+75

720

385

1140

870

8.0

27400

9.0

30800

0.25

0.25

42/39/34

42/38/33

44/42/37

28/24/19.5

120(90)

170(150)

Φ9.53

3/8

Φ15.88

5/8

45(44*1)

52(52*1)

300

1100+75

800

415

1345

950

9.0

30800

10.0

34200

0.25

0.25

42/39/34

42/38/33

44/42/37

28/24/19.5

120(90)

170(150)

Φ9.53

3/8

Φ15.88

5/8

45(44*1)

52(52*1)

300

1100+75

800

415

1345

950

11.2

38000

12.5

42500

0.25

0.25

42/39/34

42/38/33

44/42/37

28/24/19.5

120(90)

170(150)

Φ9.53

3/8

Φ15.88

5/8

45(44*1)

52(52*1)

300

1100+75

800

415

1345

950

14.0

48000

16.0

54500

0.34

0.34

43/40/35

44/39/34

47/43/38

35.5/29/24

120(90)

170(150)

Φ9.53

3/8

Φ15.88

5/8

53(50*1)

61(59*1)

300

1400+75

800

415

1640

950

16.0

54500

18.0

61500

0.43

0.43

46/40/35

45/40/34

46/42/38

39/31/24

120(90)

170(150)

Φ9.53

3/8

Φ15.88

5/8

53(50*1)

61(59*1)

300

1400+75

800

415

1640

950

Air Flow(Hi/Me/Lo)

220-240V/50Hz208V/60Hz

230V/60Hz

220-240V/50Hz

208V/60Hz

230V/60Hz

I.D.32

Model

Power Supply AC 1Φ, 220V~240V/50Hz

AVD-07

HCFCH

AVD-09

HCFCH

AVD-12

HCFCH

AVD-15

HCFCH

AVD-19

HCFCH

AVD-22

HCFCH

AVD-24

HCFCH

AVD-27

HCFCH

AVD-30

HCFCH

AVD-38

HCFCH

AVD-48

HCFCH

AVD-54

HCFCH

1.7

5,800

2.0

6,500

20

20

Model

Power Supply AC 1Φ, 220~240V/50Hz; AC 1Φ, 220V/60Hz

Sound Pressure33/32/32/

30/30/28

1/4

3/8

520/500/490/

450/430/420

kW

Btu/h

kW

Btu/h

W

W

dB(A)

mm

inch

mm

inch

mm

kg

kg

m³/h

-

mm

mm

mm

mm

mm

mm

Airflow Rate

Panel Colour

Connection Type Flare Nuts

Liquid

Gas

Drain Pipe O.D. 18

Net Weight

Gross Weight

External

Packaging

Cooling

Cooling

Heating

Heating

Capacity

Piping

Weight

Demensions

Power Input

AVS-05HJFTDD

2.2

7,500

2.5

8,500

20

20

36/35/33/

32/30/28

1/4

3/8

590/550/520/

490/450/420

AVS-07HJFTDD

2.8

9,600

3.3

11,300

20

20

36/35/33/

32/30/28

1/4

Φ6.35Φ6.35Φ6.35

Φ9.53 Φ9.53 Φ9.53

Φ6.35

Φ9.53

9

12.5

270

845

203

375

943

310

9

12.5

270

845

203

375

943

310

9

12.5

270

845

203

375

943

310

9

12.5

270

845

203

375

943

310

13

17

315

960

230

430

1058

328

14.5

19

315

1120

230

430

1223

328

14.5

19

315

1120

230

430

1223

328

14.5

19

315

1120

230

430

1223

328

Φ15.88

Φ6.35 Φ9.53

Φ15.88

Φ9.53

Φ15.88

Φ9.53

3/8

590/550/520/

490/450/420

AVS-09HJFTDD

3.6

12,300

4.0

13,700

30

30

38/35/33/

32/30/28

1/4

3/8

620/550/520/

490/450/420

AVS-12HJFTDD

4.5

15,400

5.0

17,100

20

30

38/37/36/

32/31/29

1/4

1/2

Φ12.7

690/660/620/

540/520/480

AVS-15HJFTDD

5.6

19,100

6.3

21,500

30

30

40/38/36/

35/33/31

3/8

5/8

970/900/850/

800/730/690

AVS-18HJFTDD

7.1

24,200

8.0

27,300

50

70

45/42/41/

38/35/31

3/8

5/8

1200/1080/1020/

900/800/700

AVS-24HJFTDD

8.4

28,700

8.4

28,700

80

80

50/48/45/

41/36/33

3/8

5/8

1400/1320/1200/

1020/850/730

AVS-28HJFTDD

White

H

W

D

H

W

D

The above noise values are measured in an anechoic chamber so that reflected sound

should be taken into consideration during actual operation.

The above noise values are measured under the fan mode operation, and measured at a

point 1m in front of the unit and 0.8m below the unit.

Notes: The rated capacity is based on the following conditions:

Cooling conditions: indoor air inlet temperature: 27℃ DB, 19℃ WB, outdoor air inlet temperature: 35

℃ DB, pipe length: 7.5m, pipe height diference: 0m

Heating conditions: indoor air inlet temperature: 20℃ DB, outdoor air inlet temperature: 7℃ DB, 6℃

WB, pipe length: 7.5m, pipe height diference: 0m

2.1.

Wall Mounted Type

Page 12: HISENSE CENTRAL AIR CONDITIONING

19 20

Controller Controller

Optional Part

Features Features

● Room temperature display. Individual louver control.

● Self cleaning.

● LCD display with back light

● Centigrade Fahrenheit switch

● Test run.

● 2.5D Toughened glass cover plate, delicate display and good texture.

● Built-in operation light and 6-step of backlit brightness.

● Switching between Setting TEMP and Room TEMP display.

● Flat back-cover for easy mounting.

● 11 Languages Manual.

● TEMP control and display in 0.5℃ increment.

● Neighborhood distinguish of wireless controller.

HYXE-VC01 HYE-VD01

Hi-MIT II

Humidity SensorApplicable ModelsModel Picture

3D Air-flow Panel

AirPure Kit

Panel Model

HP-CB-NA

HP-DB-NA

HP-EB-NA

Applicable Models

Ceiling ducted type ( DC / AC low-height ) 0.5-1.3HP

Ceiling ducted type ( DC / AC low-height ) 1.5-1.8HP

Ceiling ducted type ( DC / AC low-height ) 2-2.5HP

Outer Dimensions (H×W×D)

180×740×70mm

180×950×70mm

180×1220×70mm

Picture

Model

HJK-ELZB

Power Supply

AC 1Ф, 220V~240V 50/60Hz

Applicable Indoor Units

Ceiling Ducted

Picture

Hi-MotionPictureModel Applicable Models

All types of indoor units

HCHR-S01E Ceiling Ducted, Wall Mounted

HCM-S01E

Note: only apply to special wire controllers

Control is in your handsControl is in your hands

EnergyManagement

ScheduleSetting

CustomizedScenes

RemoteControl

Convenient Management

Customized Scenes Solution

Smart Design

● 2 Permission Levels

● Online Repair Report

● Strong Capability

● Control Freely

● Home-mode

● Off-duty Mode

● Schedule Setting

● Energy Management

● Stylish Appearance and

Compact Body

● High Compatibility

● Multiple Languages Options


Recommended