Page 1: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

 

 

 

 

   

2011 Cortex Medical Management Systems 

 

 

 

[HL7 INTERFACE SPECIFICATION]This document describes the Cortex implementation of the HL7 Interface standard applied to sending and receiving ADT, Orders and Result data between our pathology reporting system and the consumers of those reports. 

Page 2: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 TableofContentsTable of Contents ........................................................................................................................................................................................................... 2 

Requirements ................................................................................................................................................................................................................. 4 

Overview ........................................................................................................................................................................................................................ 4 

Connectivity ................................................................................................................................................................................................................... 5 

TCP / IP ....................................................................................................................................................................................................................... 5 

Bi‐Directionality ......................................................................................................................................................................................................... 5 

HL7 Minimal Lower Layer Protocol ............................................................................................................................................................................ 5 

ACK – Acknowledgment Message .................................................................................................................................................................................. 6 

ADT – Admit/Discharge Transfer Message .................................................................................................................................................................... 6 

Patient Admission – A01, A04, A05, A06 ................................................................................................................................................................... 6 

A01 Event – Patient Admit ..................................................................................................................................................................................... 7 

A04 Event – Patient Register.................................................................................................................................................................................. 7 

A05 Event – Patient Pre‐Admit .............................................................................................................................................................................. 7 

A06 Event – Patient Change Outpatient to Inpatient ............................................................................................................................................ 7 

Patient Transfer – A02 ............................................................................................................................................................................................... 7 

A02 Event ................................................................................................................................................................................................................... 7 

Patient Discharge – A03, A07 ..................................................................................................................................................................................... 8 

A03Event ................................................................................................................................................................................................................ 8 

A07 Event – Patient Change Inpatient to Outpatient ............................................................................................................................................ 8 

Patient Information Update – A08 ............................................................................................................................................................................. 8 

ORM / OML Order Entry Message ............................................................................................................................................................................... 10 

ORM‐O01 Generic Order Message .......................................................................................................................................................................... 10 

Page 3: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 OML‐O21 Laboratory Order Message ...................................................................................................................................................................... 11 

ORU – Observation Result Message ............................................................................................................................................................................ 13 

R01 Transmission of a result .................................................................................................................................................................................... 13 

R01 Event ............................................................................................................................................................................................................. 13 

DFT – Financial Transaction Message .......................................................................................................................................................................... 14 

P03 Event ............................................................................................................................................................................................................. 14 

Appendix A ................................................................................................................................................................................................................... 15 

EVN – Event Type ..................................................................................................................................................................................................... 15 

FT1 – Financial Transaction Segment ....................................................................................................................................................................... 15 

GT1 – Guarantor Segment ....................................................................................................................................................................................... 17 

IN1 – Insurance Segment ......................................................................................................................................................................................... 20 

IN2 ‐ Insurance Additional Information Segment .................................................................................................................................................... 22 

MSH – Message Header Segment ............................................................................................................................................................................ 26 

NTE – Notes and Comments Segment ..................................................................................................................................................................... 26 

ORC – Common Order Segment .............................................................................................................................................................................. 27 

OBR – Observation Request Segment ...................................................................................................................................................................... 28 

OBX – Observation / Result Value............................................................................................................................................................................ 31 

PID – Patient Identification Segment ....................................................................................................................................................................... 32 

PV1 – Patient Visit Information Segment ................................................................................................................................................................ 33 

SAC – Specimen Container Detail Segment ............................................................................................................................................................. 35 

SPM – Specimen Segment ....................................................................................................................................................................................... 36 

 

Page 4: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 

RequirementsDemographics, Billing, and Orders inbound require Gold version 2009 sp1 or Greater 

Results and Billing outbound require gold version 2009 or Greater 

OverviewThis document facilitates establishing bi‐directional communication between a lab using a Cortex reporting system and the consumer of those reports.  The current version of HL7 supported is 2.5.1; however the system is designed to be backward compatible with any 2.xx version of the HL7 interface. 

The purposes of the interfaces supported are as follows: 

ADT – Process patient demographic information communicated from a hospital or physician’s office in preparation for processing an order. 

ORM / OML – ORM and OML messages combine ADT information and lab order request information informing the lab of the tests to perform on the specimens provided.  An order interface is typically paired with a results interface. 

ORU – The results interface that returns the laboratory observations, typically in response to an ORM previously received. 

DFT – DFT messages convey financial information, such as the type and quantity of procedures performed.  Typically this data flows from a reporting system to a billing system.  Since Cortex has both systems, we have acted as both the sender and receiver for this message type. 

Each of these message types will be explained in detail in its own section of this document.  Each section will describe the events and segments required by each interface.  Because many of message types use the same segments, the segment description tables can be found in Appendix A. 

Page 5: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 ConnectivityCortex supports either TCP/IP or ASCII files, sometimes referred to as socket and batch mode.  The difference between the two is that TCP/IP messages are typically processed, or at least persisted immediately.  Batch mode writes a file to a shared directory and is picked up and processed on a scheduled or periodic basis. 

TCP/IPTCP/IP communications are based on the concept of ‘servers’ and ‘clients’. A client requests connection to the server.  If the server is not busy, it allows the connection.  The client will then transmit its data in the form of an HL7 message and await an acknowledgement message.  This continues until the client has no more data to transmit.  At that time, the client communicates its intention to disconnect and then does so.  By signaling that it is done, the client allows the Server to await further requests from clients.  It is important that the client disconnect in a graceful manner, because if it does not and is disconnected, the server will block any attempts to reconnect.  Typically the only way to correct this situation is to restart the server software, or at least that connection on the server. 

Bi‐DirectionalityIn terms of connectivity, all the interfaces are bi‐directional.  Messages are sent by the client and acknowledgements are received from the server.  In terms of message exchange between a lab and its client, bi‐directional typically means order and result.  While typically they are paired, they need not be and Cortex treats each order and result connection as a separate interface.  It is important to note that each interface will listen for messages on a specified server and a particular port on that server.  Each client will need to know the IP Address and port number in order to transmit to that server.  

HL7MinimalLowerLayerProtocolCortex follows the HL7 protocol recommendation for transferring data over TCP/IP as follows: 

Each transmission begins with ASCII 11  Each message is separated with ASCII 13  Each transmission ends with ASCII 28 and ASCII 13 

   

Page 6: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 ACK–AcknowledgmentMessageThe receiving system responds with an ACK message upon successful receipt of a data message. 

Segment SegmentName Required/Optional

Comments

MSH  Message Header   R   MSA  Message Identification   R   

ADT–Admit/DischargeTransferMessageADT messages exchange patient demographics between the lab system and our interface partner.  Different events indicate how the message should be handled.  Cortex supports events A01, A02, A03, A04, A05, A06, A07, A08, A18, A34, A40, A41 and A42.  All other events will be ignored.   

PatientAdmission–A01,A04,A05,A06Where a facility treating patients may be concerned with the type of visit (in‐patient, out‐patient, emergency) and where the patient falls within the admission process (registered, pre‐admitted, admitted), the lab typically is not concerned.  It is important that the patient’s status is now such that care is being provided and tests may be ordered on the facilities behalf.  Note, Cortex can record patient visit type, admit and discharge dates, typically for billing purposes.   

Segment SegmentName Required/Optional

Comment

MSH  Message Header  R   EVN  Event Type  R   PID  Patient Identification  R  Patient demographics PV1  Patient Visit Information  O  Used for tracking admission information GT1  Guarantor  O  Typically a parent, spouse, or legal 

guardian ‐‐‐  Insurance Info Group  O  Group may repeat 3 times.  If no COB 

Priority information is provided in the IN1 

Page 7: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 segment, it is assumed they are in order of priority 

IN1  Insurance Information  O  Required if any insurance info is sent IN2  Additional Insurance Info  O  Not required even if IN1 is given 

A01Event–PatientAdmitAn A01 event is used to indicate a patient has been admitted to a facility, or a new account created in the sending system.  Use PV1‐44 for the Admit Date/Time and PV1‐3 will contain the location assigned to the patient. 

A04Event–PatientRegisterThe A04 event is used to indicate a patient has arrived, but not assigned a bed typically this indicates an outpatient status.  Use PV1‐44 to indicate the time the patient has arrived for the visit. 

A05Event–PatientPre‐AdmitThe A05 event is used to indicate a patient has not been admitted yet, but is considered within the system in preparation for admission.  Cortex treats this exactly as an A04 event except it will not expect PV1‐44 to be filled in. 

A06Event–PatientChangeOutpatienttoInpatientCortex treats A06 exactly the same as A01. 

PatientTransfer–A02

A02EventThe A02 event is used to indicate a patient has moved to a new location, typically the room and bed information changes. 

Segment SegmentName Required/Optional

Comment

MSH  Message Header  R   EVN  Event Type  R   PID  Patient Identification  R   PV1  Patient Visit Information  R  PV1‐3 will contain current location info 

and PV1‐6 will contain previous location. 

Page 8: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 PatientDischarge–A03,A07When a patient is discharged, it is an indication that treatment has been completed and further tests for the patient will not be at the request of the facility, at least for this visit. 

A03EventThe A03 event is used to indicate a patient has been discharged from a facility.  If the patient has been discharged, update PV1‐45 with the discharged date. PV1‐3 will contain location info prior to discharge.  If the patient has expired, fill in PID‐29 and PID‐30.  

A07Event–PatientChangeInpatienttoOutpatientCortex treats A07 exactly the same as A03. 

Segment SegmentName Required/Optional

Comment

MSH  Message Header  R   EVN  Event Type  R   PID  Patient Identification  R  Patient demographics PV1  Patient Visit Information  O  Used for tracking admission information GT1  Guarantor  O  Typically a parent, spouse, or legal 

guardian ‐‐‐  Insurance Info Group  O  Group may repeat 3 times.  If no COB 

Priority information is provided in the IN1 segment, it is assumed they are in order of priority 

IN1  Insurance Information  O  Required if any insurance info is sent IN2  Additional Insurance Info  O  Not required even if IN1 is given 

 

PatientInformationUpdate–A08The A08 event is used to update any patient information.  By default, Cortex only updates patients already within our system, but it is a common request to insert new accounts based on this event.  If that is the case, it is treated as an A01 event. 

Page 9: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 

Segment SegmentName Required/Optional

Comment

MSH  Message Header  R   EVN  Event Type  R   PID  Patient Identification  R  Patient demographics PV1  Patient Visit Information  O  Used for tracking admission information GT1  Guarantor  O  Typically a parent, spouse, or legal 

guardian ‐‐‐  Insurance Info Group  O  Group may repeat 3 times.  If no COB 

Priority information is provided in the IN1 segment, it is assumed they are in order of priority 

IN1  Insurance Information  O  Required if any insurance info is sent IN2  Additional Insurance Info  O  Not required even if IN1 is given 

 

Page 10: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 ORM/OMLOrderEntryMessageEach orders interface can use one of two message types; ORM‐O01 and OML‐O21.  The main difference between the two is that OML‐O21 has specific segments dedicated to contain the characteristics of specimens and specimen containers.   

The orders system in Cortex has a major deviation from the standard in that we only allow one OBR segment per order message.  Since each order creates a case in Cortex, it presents difficulty in ordering multiple procedures. 

ORM‐O01GenericOrderMessageThis is the traditional method used for submitting orders to the lab.  In the future, it is likely that ORM messages will be replaced by OML messages. 

Segment SegmentName Required/Optional

Comment

MSH  Message Header  R   PID  Patient Identification  R  Patient demographics PV1  Patient Visit Information  O  Used for tracking admission information ‐‐‐  Insurance Info Group  O  Group may repeat 3 times.  If no COB 

Priority information is provided in the IN1 segment, it is assumed they are in order of priority 

IN1  Insurance Information  O  Required if any insurance info is sent IN2  Additional Insurance Info  O  Not required even if IN1 is given GT1  Guarantor  O  Typically a parent, spouse, or legal 

guardian ORC  Common Order  O  Used to provide order encounter details. 

Only one ORC is expected. ‐‐‐  Order Details  R  Only one allowed OBR  Observation Request  R  Used to provide order specific details, 

such as request a lab procedure. NTE  Notes and Comments  O  Default to Clinical History. Use of the 

SourceOfComment field can be 

Page 11: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 negotiated to add text to data fields such as Gross and Micro 

‐‐‐  Observations  O  Repeatable OBX  Observation/Result  O  Not typically used in orders  NTE  Notes and Comments  O  Specific to OBX.  

OML‐O21LaboratoryOrderMessageAnother message structure used for submitting orders to the lab, OML messages are often used to send data to automated laboratory equipment. 

Segment SegmentName Required/Optional

Comment

MSH  Message Header  R   PID  Patient Identification  R  Patient demographics PV1  Patient Visit Information  O  Used for tracking admission information ‐‐‐  Insurance Info Group  O  Group may repeat 3 times.  If no COB 

Priority information is provided in the IN1 segment, it is assumed they are in order of priority 

IN1  Insurance Information  O  Required if any insurance info is sent IN2  Additional Insurance Info  O  Not required even if IN1 is given GT1  Guarantor  O  Typically a parent, spouse, or legal 

guardian ORC  Common Order  O  Used to provide order encounter details. 

Only one ORC is expected. ‐‐‐  Order Details  R  Only one allowed OBR  Observation Request  R  Used to provide order specific details, 

such as request a lab procedure. NTE  Notes and Comments  O  Default to Clinical History. Use of the 

SourceOfComment field can be negotiated to add text to data fields such 

Page 12: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 as Gross and Micro 

‐‐‐  Observations  O  Repeatable OBX  Observation/Result  O  Not typically used in orders  NTE  Notes and Comments  O  Specific to OBX.  ‐‐‐  Specimens  O  Repeatable SPM  Specimen  O  Characteristics of specimen OBX  Observations related to 

Specimen O  Repeatable 

SAC  Specimen Container  O  Characteristics of specimen container. Only one container expected per specimen 

OBX  Observations related to Specimen Container 

O  Repeatable 

 

Page 13: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 ORU–ObservationResultMessageORU messages provide cases based results to our interface partner.   Cortex will only generate R01 Events. 

R01TransmissionofaresultThese events exist to transfer results to a host system. 

R01Event

Segment SegmentName Required/Optional

Comment

MSH  Message Header  R   EVN  Event Type  R   PID  Patient Identification  R  Patient demographics ORC  Common Order  O  Used to provide order encounter details OBR  Observation Request  R  Used to provide order specific details OBX  Observation/Results   R  Used to provide results on an order NTE  Notes and Comments  O  Used to provide additional notes 

The result message may be sent 2 ways the first is the result message is contained in a series of OBX level results, many systems post each OBX as separate results and do not retain specific formatting. The second method is be including the report as a series of NTE segments follow an initial OBX that results as “See Note”.  Not all systems accept this second method. 

Also once a client is upgraded to version 9 and their print server is installed with Office 2007 the client has the option of including an encoded PDF message with their results. 

 

Page 14: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 DFT–FinancialTransactionMessageThe Detail Financial Transaction message is used to describe financial transactions between systems.  At Cortex, we only allow the P03 event over an interface to an external system.  Regardless of whether the information is inbound or outbound, the layout is the same. 

P03Event

Segment SegmentName Required/Optional

Comment

MSH  Message Header  R   EVN  Event Type  R   PID  Patient Identification  R  Patient demographics PV1  Patient Visit Information  O  Used for tracking admission information FT1  Financial Transaction  O  This is where the FT1 segment falls in the 

sequence described by the HL7 specification, however, we have legacy interfaces that send the FT1 segment following the other segments.  Either way is acceptable as long as it is consistent within the interface.  Repeats 

GT1  Guarantor  O  Typically a parent, spouse, or legal guardian 

‐‐‐  Insurance Info Group  O  Group may repeat 3 times.  If no COB Priority information is provided in the IN1 segment, it is assumed they are in order of priority 

IN1  Insurance Information  O  Required if any insurance info is sent IN2  Additional Insurance Info  O  Not required even if IN1 is given FT1  Financial Transaction  O  Alternate sequence order.  If this segment 

is sent, do not send the one above Patient demographic information sent will be treated the same as an ADT‐A01 event.  If the data is inbound and the patient can be matched, the data from the interface will not update the existing information unless specifically defined in the specification.   

Page 15: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 AppendixA

EVN–EventType

SEQ Len DT OPT ElementName CortexLocation Comment1  3  ID  B  Event Type Code    Not used 2  26  TS  R  Recorded Date/Time    Time transaction entered. Used if Event 

Occurred not provided. 3  26  TS  O  Date/Time Planned Event    Not used 4  3  IS  O  Event Reason Code    Not used 5  250  XCN  O  Operator ID    Not used 6  26  TS  O  Event Occurred    Actual Time of event  occurred 7  241  HD  O  Event Facility    Not used 

FT1–FinancialTransactionSegment

SEQ Len DT OPT ElementName CortexLocation Comment1   4   SI   O   Set ID ‐ FT1      2   12   ST   O   Transaction ID      3   10   ST   O   Transaction Batch ID   Service.BatchNumber   4   53   DR   R   Transaction Date   Service.FromDate  Date sample collected.  Default to 

current date if not provided. 5   26   TS   O   Transaction Posting Date   Service.EnteredDate  Current date 6   8   IS   R   Transaction Type   If charge, then a service record is created.  Credit / Charge field, typically only accept 

charges 7   250   CE   R   Transaction Code   Service.ServiceItem  Billed Item, often CPT code.  May need to 

create translation table. 8   40   ST   B   Transaction Description     Used only if Service Item does not 

contain a billing description 9   40   ST   B   Transaction Description ‐ 

Alt     

10   6   NM   O   Transaction Quantity   Service.Units   11   12   CP   O   Transaction Amount ‐ 

Extended     

Page 16: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 12   12   CP   O   Transaction Amount ‐ Unit      13   250   CE   O   Department Code      14   250   CE   O   Insurance Plan ID   Service.PayorNumber  Primary insurance plan ID.  Translation 

may be required.  IN1 data will probably contain reference to the same plan. 

15   12   CP   O   Insurance Amount      16   80   PL   O   Assigned Patient Location   Service.LocationNumber  Location where the service was ordered.   17   1   IS   O   Fee Schedule      18   2   IS   O   Patient Type      19   250   CE   O   Diagnosis Code ‐ FT1   Service.ICDCodes (1‐4)  Repeating multi‐value field separated by 

repetition delimiter (usually ~) 20   250   XCN   O   Performed By Code   Service.PerformedByID  Pathologist or Tech that performed the 

lab procedure.  May need translation table. 

21   250   XCN   O   Ordered By Code   Service.ReferredByID  Doctor that ordered the lab test. May need translation table. 

22   12   CP   O   Unit Cost   Typically not used  Looked up on Service Item table. 23   427   EI   O   Filler Order Number   Service.CaseNumber  Typically Accession Number from lab 

system. 24   250   XCN   O   Entered By Code      25   250   CE   O   Procedure Code    CPTCode typically comes from Service 

Item record. 26   250   CE   O   Procedure Code Modifier   Service.Modifier1   27   250   CE   O   Advanced Beneficiary 

Notice Code     

28   250   CWE   O   Medically Necessary Duplicate Procedure Reason.  

  

29   250   CNE   O   NDC Code      30   250   CX   O   Payment Reference ID      31   4   SI   O   Transaction Reference Key       

Page 17: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 GT1–GuarantorSegment

SEQ Len DT OPT ElementName CortexLocation Comment1  4  SI  R  Set ID ‐ GT1      2  250  CX  O  Guarantor Number      3  250  XPN  R  Guarantor Name   PatientPayor ‐ SubscriberName   4  250  XPN  O  Guarantor Spouse Name      5  250  XAD  O  Guarantor Address   PatientPayor ‐SubscriberAddressLine1, 

SubscriberAddressLine2, City, State, ZipCode 

 

6  250  XTN  O  Guarantor Ph Num ‐ Home   PatientPayor – PhoneNo   7  250  XTN  O  Guarantor Ph Num ‐ 

Business     

8  26  TS  O  Guarantor Date/Time Of Birth  

PatientPayor –SubscriberBirthdate   

9  1  IS  O  Guarantor Administrative Sex  

PatientPayor –SubscriberSex   

10  2  IS  O  Guarantor Type      11  250  CE  O  Guarantor Relationship   PatientPayor ‐SubscriberRelation   12  11  ST  O  Guarantor SSN   PatientPayor –SubscriberSocSecNo   13  8  DT  O  Guarantor Date ‐ Begin      14  8  DT  O  Guarantor Date ‐ End      15  2  NM  O  Guarantor Priority      16  250  XPN  O  Guarantor Employer Name   PatientPayor –EmployerName   17  250  XAD  O  Guarantor Employer 

Address     

18  250  XTN  O  Guarantor Employer Phone Number  

   

19  250  CX  O  Guarantor Employee ID Number  

   

20  2  IS  O  Guarantor Employment Status  

   

21  250  XON  O  Guarantor Organization     

Page 18: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 Name  

22  1  ID  O  Guarantor Billing Hold Flag      23  250  CE  O  Guarantor Credit Rating 

Code     

24  26  TS  O  Guarantor Death Date And Time  

   

25  1  ID  O  Guarantor Death Flag      26  250  CE  O  Guarantor Charge 

Adjustment Code     

27  10  CP  O  Guarantor Household Annual Income  

   

28  3  NM  O  Guarantor Household Size      29  250  CX  O  Guarantor Employer ID 

Number     

30  250  CE  O  Guarantor Marital Status Code  

   

31  8  DT  O  Guarantor Hire Effective Date  

   

32  8  DT  O  Employment Stop Date      33  2  IS  O  Living Dependency      34  2  IS  O  Ambulatory Status      35  250  CE  O  Citizenship      36  250  CE  O  Primary Language      37  2  IS  O  Living Arrangement      38  250  CE  O  Publicity Code      39  1  ID  O  Protection Indicator      40  2  IS  O  Student Indicator      41  250  CE  O  Religion      42  250  XPN  O  Mother’s Maiden Name      43  250  CE  O  Nationality      44  250  CE  O  Ethnic Group      45  250  XPN  O  Contact Person’s Name      46  250  XTN  O  Contact Person’s Telephone     

Page 19: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 Number  

47  250  CE  O  Contact Reason      48  3  IS  O  Contact Relationship      49  20  ST  O  Job Title      50  20  JCC  O  Job Code/Class      51  250  XON  O  Guarantor Employer’s 

Organization Name     

52  2  IS  O  Handicap      53  2  IS  O  Job Status      54  50  FC  O  Guarantor Financial Class      55  250  CE  O  Guarantor Race      

 

Page 20: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 IN1–InsuranceSegmentTypically, insurance information is used in filling out a specific patients insurance information.  However, it can also be used to create payors in the Cortex system if they do not already exist. 

SEQ Len DT OPT ElementName CortexLocation Comment1   4   SI   R   Set ID ‐ IN1      2   250   CE   R   Insurance Plan ID      3   250   CX   R   Insurance Company ID   PatientPayor –PayorNumber, Payor‐ 

Number  

4   250   XON   O   Insurance Company Name   Payor – Name   5   250   XAD   O   Insurance Company 

Address  Payor – AddressLine1, AddressLine2, City, State, ZipCode 

 

6   250   XPN   O   Insurance Co Contact Person  

Payor – ContactPerson Name   

7   250   XTN   O   Insurance Co Phone Number  

Payor – TelephoneNumber   

8   12   ST   O   Group Number   PatientPayor – GroupNumber   9   250   XON   O   Group Name      10   250   CX   O   Insured’s Group Emp ID      11   250   XON   O   Insured’s Group Emp 

Name    Can house EmployerName if IN2 not sent 

12   8   DT   O   Plan Effective Date   PatientPayor – DateCoverageBegins   13   8   DT   O   Plan Expiration Date   PatientPayor – DateCoverageEnds   14   239   AUI   O   Authorization Information   PatientPayor – AuthorizationNumber   15   3   IS   O   Plan Type   PatientPayor – InsuranceType; Payor – 

TypeCode  

16   250   XPN   O   Name Of Insured   PatientPayor – SubscriberName   17   250   CE   O   Insured’s Relationship To 

Patient  PatientPayor –SubscriberRelation   

18   26   TS   O   Insured’s Date Of Birth   PatientPayor –SubscriberBirthdate   19   250   XAD   O   Insured’s Address   PatientPayor ‐SubscriberAddressLine1, 

SubscriberAddressLine2, City, State,  

Page 21: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 ZipCode 

20   2   IS   O   Assignment Of Benefits   PatientPayor – AcceptAssignment   21   2   IS   O   Coordination Of Benefits      22   2   ST   O   Coordination Of Ben. 

Priority  PatientPayor – Type  P,S, T ‐ Primary, Secondary, Tertiary 

23   1   ID   O   Notice Of Admission Flag      24   8   DT   O   Notice Of Admission Date      25   1   ID   O   Report Of Eligibility Flag      26   8   DT   O   Report Of Eligibility Date      27   2   IS   O   Release Information Code      28   15   ST   O   Pre‐Admit Cert (PAC)      29   26   TS   O   Verification Date/Time      30   250   XCN   O   Verification By      31   2   IS   O   Type Of Agreement Code      32   2   IS   O   Billing Status      33   4   NM   O   Lifetime Reserve Days      34   4   NM   O   Delay Before L.R. Day      35   8   IS   O   Company Plan Code      36   15   ST   O   Policy Number   PatientPayor – PolicyNumber   37   12   CP   O   Policy Deductible      38   12   CP   B   Policy Limit ‐ Amount      39   4   NM   O   Policy Limit ‐ Days      40   12   CP   B   Room Rate ‐ Semi‐Private      41   12   CP   B   Room Rate ‐ Private      42   250   CE   O   Insured’s Employment 

Status     

43   1   IS   O   Insured’s Administrative Sex  

PatientPayor –SubscriberSex   

44   250   XAD   O   Insured’s Employer’s Address  

   

45   2   ST   O   Verification Status      46   8   IS   O   Prior Insurance Plan ID      47   3   IS   O   Coverage Type      

Page 22: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 48   2   IS   O   Handicap      49   250   CX   O   Insured’s ID Number      50   1   IS   O   Signature Code   PatientPayor ‐ SignatureSourceCode  C, S, M, P 51   8   DT   O   Signature Code Date      52   250   ST   O   Insured’s Birth Place      53   2   IS   O   VIP Indicator      

IN2‐InsuranceAdditionalInformationSegment

SEQ Len DT OPT ElementName CortexLocation Comment1   250   CX   O   Insured’s Employee ID      2   11   ST   O   Insured’s Social Security 

Number  PatientPayor –SubscriberSocSecNo   

3   250   XCN   O   Insured’s Employer’s Name and ID  

PatientPayor –EmployerName   

4   1   IS   O   Employer Information Data      5   1   IS   O   Mail Claim Party      6   15   ST   O   Medicare Health Ins Card 

Number     

7   250   XPN   O   Medicaid Case Name      8   15   ST   O   Medicaid Case Number      9   250   XPN   O   Military Sponsor Name      10   20   ST   O   Military ID Number      11   250   CE   O   Dependent Of Military 

Recipient     

12   25   ST   O   Military Organization      13   25   ST   O   Military Station      14   14   IS   O   Military Service      15   2   IS   O   Military Rank/Grade      16   3   IS   O   Military Status      17   8   DT   O   Military Retire Date      18   1   ID   O   Military Non‐Avail Cert On 

File     

Page 23: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 19   1   ID   O   Baby Coverage      20   1   ID   O   Combine Baby Bill      21   1   ST   O  Blood Deductible     22   250   XPN   O   Special Coverage Approval 

Name     

23   30   ST   O  Special Coverage Approval Title  

   

24   8   IS   O   Non‐Covered Insurance Code  

   

25   250   CX   O   Payor ID      26   250   CX   O  Payor Subscriber ID      22   250   XPN   O  Special Coverage Approval 

Name     

23   30   ST   O  Special Coverage Approval Title  

   

24   8   IS   O  Non‐Covered Insurance Code  

   

25   250   CX   O   Payor ID      26   250   CX   O   Payor Subscriber ID      27   1   IS   O  Eligibility Source      28   82   RMC   O   Room Coverage 

Type/Amount     

29   56   PTA   O    Policy Type/Amount      30   25   DDI   O   Daily Deductible     31   2   IS   O   Living Dependency      32   2   IS   O   Ambulatory Status      33   250   CE   O   Citizenship      34   250   CE   O   Primary Language      35   2   IS   O   Living Arrangement      36   250   CE   O   Publicity Code      37   1   ID   O   Protection Indicator      38   2   IS   O   Student Indicator      39   250   CE   O   Religion      

Page 24: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 40   250   XPN   O   Mother’s Maiden Name      41   250   CE   O   Nationality      42   250   CE   O   Ethnic Group      43   250   CE   O   Marital Status      44   8   DT   O   Insured’s Employment Start 

Date     

45   8   DT   O   Employment Stop Date      46   20   ST   O   Job Title      47   20   JCC   O   Job Code/Class      48   2   IS   O   Job Status      49   250   XPN   O   Employer Contact Person 

Name     

50   250   XTN   O   Employer Contact Person Phone Number  

   

51   2   IS   O   Employer Contact Reason      52   250   XPN   O   Insured’s Contact Person’s 

Name     

53   250   XTN   O   Insured’s Contact Person Phone Number  

   

54   2   IS   O   Insured’s Contact Person Reason  

   

55   8   DT   O   Relationship to the Patient Start Date  

   

56   8   DT   O   Relationship to the Patient Stop Date  

   

57   2   IS   O   Insurance Co. Contact Reason  

   

58   250   XTN   O   Insurance Co Contact Phone Number  

   

59   2   IS   O   Policy Scope      60   2   IS   O   Policy Source      61   250   CX   O   Patient Member Number      62   250   CE   O   Guarantor’s Relationship to     

Page 25: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 Insured  

63   250   XTN   O   Insured’s Phone Number ‐ Home  

   

64   250   XTN   O   Insured’s Employer Phone Number  

   

65   250   CE   O   Military Handicapped Program  

   

66   1   ID   O   Suspend Flag      67   1   ID   O   Copay Limit Flag      68   1   ID   O   Stoploss Limit Flag      69   250   XON   O   Insured Organization Name 

and ID     

 

Page 26: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 MSH–MessageHeaderSegment

SEQ Len DT OPT ElementName CortexLocation Comment1  1  ST  R  Field Separator     2  4  ST  R  Encoding Characters     3  227  HD  O  Sending Application     4  227  HD  R  Sending Facility     5  227  HD  O  Receiving Application     6  227  HD  R  Receiving Facility     7  26  TS  R  Date/Time of Message     8  40  ST  O  Security    Not used 9  15  MSG  R  Message Type     10  20  ST  R  Message Control ID    Unique message ID 11  3  PT  R  Processing ID    P = Production, T = Test 12  60  VID  R  Version ID    Default = 2.5.1 13  15  NM  O  Sequence Number     14  180  ST  O  Continuation Pointer     15  2  ID  O  Accept Acknowledgement 

Type    

16  2  ID  O  Application Acknowledgment Type 

   

17  3  ID  O  Country Code     18  16  ID  O  Character Set     19  250  CE  O  Principal Language of 

Message    

20  20  ID  O  Alternate Character Set     21  427  EI  O  Message Profile Identifier     

NTE–NotesandCommentsSegmentNotes are often used to transmit data that doesn’t fit elsewhere.  This segment could be used to populate specific fields on the case, such as gross description by using the source of comment field to instruct the system on how to handle the text. The Comment Type field could then be used to pass information such as transcriber ID and name. 

Page 27: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 

SEQ Len DT OPT ElementName CortexLocation Comment1   4   SI   O   Set ID ‐ NTE     

2   8   ID   O  Source of Comment   Negotiated handling code, such as 

GROSS 3   65000   FT   O   Comment    Text to process 4   250   CE   O   Comment Type    Transcribed by  

ORC–CommonOrderSegmentThe common order segment contains data that on a level roughly equivalent to a cortex case.  The data is common to all the procedures on the case. 

SEQ Len DT OPT ElementName CortexLocation Comment1   2   ID   R   Order Control     2   22   EI   C   Placer Order Number  Orders.Usertext2  Stored and returned in result 3   22   EI   C   Filler Order Number  Orders.Usertext3  Result usually returns accession number 4   22   EI   O   Placer Group Number     5   2   ID   O   Order Status    (P)reliminary, (C)hanged, (F)inal 6   1   ID   O   Response Flag     7   200   TQ   B   Quantity/Timing     8   200   EIP   O   Parent     

9   26   TS   O   Date/Time of Transaction 

Patient_List.EnteredDate; Patient_RiskFactor.EnteredDate; Orders.CollectedDate 

Result returns ResultsInterfaceDate 

10   250   XCN   O   Entered By     11   250   XCN   O   Verified By     12   250   XCN   O   Ordering Provider  Orders.CortexClinicianNumber  Will become the clinician on the case 13   80   PL   O   Enterer's Location     14   250   XTN   O   Call Back Phone Number     15   26   TS   O   Order Effective Date/Time     

Page 28: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 16   250   CE   O   Order Control Code Reason     17   250   CE   O   Entering Organization     18   250   CE   O   Entering Device     19   250   XCN   O   Action By     

20   250   CE   O  Advanced Beneficiary Notice Code 

   

21   250   XON   O   Ordering Facility Name  Orders.CortexHospitalID  Will become the hospital Id on the case 22   250   XAD   O   Ordering Facility Address     

23   250   XTN   O  Ordering Facility Phone Number 

   

24   250   XAD   O   Ordering Provider Address     25   250   CWE   O   Order Status Modifier     

26   60   CWE   C  Advanced Beneficiary Notice Override Reason 

   

27   26   TS   O  Filler's Expected Availability Date/Time 

   

28   250   CWE   O   Confidentiality Code     29   250   CWE   O   Order Type     30   250   CNE   O   Enterer Authorization Mode     

31   250   CWE   O  Parent Universal Service Identifier 

   

OBR–ObservationRequestSegmentThe observation request is roughly equivalent to a case procedure.  While the case is capable of containing multiple procedures, the order process can only import one. 

SEQ Len DT OPT ElementName CortexLocation Comment1   4   SI   O   Set ID ‐ OBR     2   22   EI   C   Placer Order Number  Orders.Usertext2  Alternative to using ORC field 3   22   EI   C   Filler Order Number  Orders.Usertext2  Alternative to using ORC field 4   250   CE   R   Universal Service Identifier  Orders.Usertext4;  Often returned in result; Identifier is 

Page 29: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 Orders.ProcedureShortName  copied to procedureShortName 

5   2   ID   B   Priority – OBR     6   26   TS   B   Requested Date/Time     

7   26   TS   C   Observation Date/Time # Orders.CollectedDate  Will become the case collected date 

Alternate to using ORC field 8   26   TS   O   Observation End Date/Time #     9   20   CQ   O   Collection Volume *     10   250   XCN   O   Collector Identifier *     11   1   ID   O   Specimen Action Code *     12   250   CE   O   Danger Code  Used to fill out Patient_RiskFactor  Depends on data received 13   300   ST   O   Relevant Clinical Information  Orders.RequisitionComments   

14   26   TS   B  Specimen Received Date/Time * 

   

15   300   SPS   B   Specimen Source 

Orders_Specimen.CortexSpecimenCode; Orders_Specimen.Location; Orders.CortexPapCollectionMethod 

NameOrCode; Free text used to describe specimen location; optional code that can be translated into a cortex code 

16   250   XCN   O   Ordering Provider Orders.CortexClinicianNumber  Will become the clinician on the case. 

Alternate to using ORC‐12 

17   250   XTN   O  Order Callback Phone Number 

   

18   60   ST   O   Placer Field 1     19   60   ST   O   Placer Field 2     20   60   ST   O   Filler Field 1 +     21   60   ST   O   Filler Field 2 +     

22   26   TS   C  Results Rpt/Status Chng ‐ Date/Time + 

   

23   40   MOC   O   Charge to Practice +     24   10   ID   O   Diagnostic Serv Sect ID     25   1   ID   C   Result Status +     26   400   PRL   O   Parent Result +     

Page 30: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 27   200   TQ   B   Quantity/Timing     28   250   XCN   O   Result Copies To     29   200   EIP   O   Parent     30   20   ID   O   Transportation Mode     31   250   CE   O   Reason for Study  Used to fill out Patient_List  Depends on data received 32   200   NDL   O   Principal Result Interpreter +     33   200   NDL   O   Assistant Result Interpreter +     34   200   NDL   O   Technician +     35   200   NDL   O   Transcriptionist +     36   26   TS   O   Scheduled Date/Time +     

37   4   NM   O  Number of Sample Containers * 

   

38   250   CE   O  Transport Logistics of Collected Sample * 

   

39   250   CE   O   Collector's Comment *  Orders.RequistionComments   

40   250   CE   O  Transport Arrangement Responsibility 

   

41   30   ID   O   Transport Arranged     42   1   ID   O   Escort Required     

43   250   CE   O  Planned Patient Transport Comment 

   

44   250   CE   O   Procedure Code     45   250   CE   O   Procedure Code Modifier     

46   250   CE   O  Placer Supplemental Service Information 

   

47   250   CE   O  Filler Supplemental Service Information 

   

48   250   CWE   C  Medically Necessary Duplicate Procedure Reason. 

   

49   2   IS   O   Result Handling     

50   250   CWE   O  Parent Universal Service Identifier 

   

Page 31: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 OBX–Observation/ResultValueDepending on the interface, the OBX may be sent one or more times.  If multiple OBX segments are employed, they may contain data in a?here? 

SEQ Len DT OPT ElementName CortexLocation Comment1   4   SI   O   Set ID – OBX      2   2   ID   C   Value Type     Typically FT, ST 3   250   CE   R   Observation Identifier     Procedure code or USI from order 4   20   ST   C   Observation Sub‐ID     Sometimes used a s a ‘Field’ name 5   65000  varies   C   Observation Value     Text containing findings 6   250   CE   O   Units      7   60   ST   O   References Range      8   5   IS   O   Abnormal Flags      9   5   NM   O   Probability      10   2   ID   O   Nature of Abnormal Test      11   1   ID   R   Observation Result Status     Typically P, C, F 12   26   TS   O   Effective Date of Reference 

Range Values     

13   20   ST   O   User Defined Access Checks  

   

14   26   TS   O   Date/Time of the Observation  

   

15   250   CE   O   Producer's Reference      16   250   XCN   O   Responsible Observer      17   250   CE   O   Observation Method      18   22   EI   O   Equipment Instance 

Identifier     

19   26   TS   O   Date/Time of the Analysis      23   567   XON   O   Performing Organization 

Name     

24   631   XAD   O   Performing Organization Address  

   

25   3002   XCN   O   Performing Organization     

Page 32: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 Medical Director  

PID–PatientIdentificationSegment

SEQ Len DT OPT ElementName CortexLocation Comment

1  4  SI  O  Set ID     Cortex will always assume only one PID segment per message 

2  20  CX  B  Patient ID  Patient.UserText1‐2    

3  250  CX  R  Patient ID List  PartnerID will be used in InterfaceKeyTranslation 

Typical entry will be like: <PartnerID>&&&<PartnerName> ^1234567890&&&MRN ^555‐55‐5555&&&SSN 

4  20  CX  B  Alternate Patient ID  Patient.UserText1‐2    5  250  XPN  R  Patient Name  Patient.Name  Only 1 name expected 

6  250  XPN  O  Mother’s Maiden Name       

7  26  TS  O  Date of Birth  Patient.Birthdate    

8  1  IS  O  Gender  Patient.Sex  M,F, and U are typical accepted values, conversion is possible 

9  250  XPN  B  Patient Alias  Patient.AliasName  Only 1 name expected 

10  250  CE  O  Race  Patient.Race  Code must be translated to Cortex System Code 

11  250  XAD  O  Patient Address  Patient.AddressLine1, Patient.AddressLine2, Patient.City, Patient.State, Patient.ZipCode  Only 1 address expected 

12  4  IS  B  County Code       13  250  XTN  O  Home Phone Number  Patient.PhoneNo1  Only 1 number expected 14  250  XTN  O  Work Phone Number  Patient.PhoneNo2  Only 1 number expected 15  250  CE  O  Primary Language       16  250  CE  O  Marital Status  Patient.MaritalStatus   17  250  CE  O  Religion       

18  250  CX  O  Patient Account Number  Patient.UserText1‐2  Account and Patient are the same entity in Cortex 

Page 33: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 19  16  ST  B  Social Security Number  Patient.SocialSecurityNo   20  25  DLN  B  Driver’s License Number       21  250  CX  O  Mother’s Identifier       22  250  CE  O  Ethnic Group       23  250  ST  O  Birth place       24  1  ID  O  Multiple birth indicator       25  2  NM  O  Birth order       26  250  CE  O  Citizenship       27  250  CE  O  Veteran military status       28  250  CE  B  Nationality       

29  26  TS  O  Patient Death Date and Time  Patient.ExpiredDate, Patient.ExpiredTime   

30  1  ID  O  Patient Death Indicator      31  1  ID  O  Identity Unknown       32  20  IS  O  Identity Reliability Code       33  26  TS  O  Last Updated Date/Time       34  241  HD  O  Last Update Facility       35  250  CE  C  Species Code       36  250  CE  C  Breed Code       37  80  ST  O  Strain       38  250  CE  O  Production Class Code       39  250  CWE  O  Tribal Citizenship       

PV1–PatientVisitInformationSegmentSEQ  Len  DT  OPT  Element Name  Cortex Location  Comment 

1  4  SI  O  Set ID     Cortex will always assume only one PV1 segment per message 

2  1  IS  R  Patient Class  As part of Admission.RoomAndBed, or Admission.UserText(1‐4) 

E, I, O for emergency, in‐patient, and out‐patient 

3  80  PL  O  Assigned Patient Location  Admission.RoomAndBed   4  2  IS  O  Admission Type    Can be used to set auto accident / work 

Page 34: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 injury flags 

5  250  CX  O  Pre‐Admit Number     6  80  PL  O  Prior Patient Location     7  250  XCN  O  Attending Doctor  Admisson.AttendingClinicianID   8  250  XCN  O  Referring Doctor     9  250  XCN  O  Consulting Doctor     10  3  IS  O  Hospital Service     11  80  PL  O  Temporary Location     12  2  IS  O  Pre‐Admit Test Indicator     13  2  IS  O  Re‐Admit Indicator     14  6  IS  O  Admit Source     15  2  IS  O  Ambultory Status     16  2  IS  O  VIP Indicator     17  250  XCN  O  Admitting Doctor     18  2  IS  O  Patient Type     19  250  CX  R  Visit Number  Admission.Number  Deviation from standard 

20  50  FC  O  Financial Class    Has been used to indicate patient vs. client responsibility 

21  2  IS  O  Charge Price Indicator    Fee schedule to use 22  2  IS  O  Courtesy Code     23  2  IS  O  Credit Rating     24  2  IS  O  Contract Code     25  8  DT  O  Contract Effective Date     26  12  NM  O  Contract Amount     27  3  NM  O  Contract Period     28  2  IS  O  Interest Code     29  4  IS  O  Transfer to Bad Debt Code     30  8  DT  O  Transfer to Bad Debt Date     31  10  IS  O  Bad Debt Agency Code     

Page 35: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 SAC–SpecimenContainerDetailSegment

SEQ Len DT OPT ElementName CortexLocation Comment1   80   EI   O   External Accession Identifier      2   80   EI   O   Accession Identifier      3   80   EI   C   Container Identifier      4   80   EI   C   Primary (parent) Container 

Identifier     

5   80   EI   O   Equipment Container Identifier  

   

6   300   SPS   C   Specimen Source      7   26   TS   O   Registration Date/Time      8   250   CE   O   Container Status      9   250   CE   O   Carrier Type      10   80   EI   O   Carrier Identifier      11   80   NA   O   Position in Carrier      12   250   CE   O   Tray Type ‐ SAC      13   80   EI   O   Tray Identifier      14   80   NA   O   Position in Tray      15   250   CE   O   Location      16   20   NM   O   Container Height      17   20   NM   O   Container Diameter      18   20   NM   O   Barrier Delta      19   20   NM   O   Bottom Delta      20   250   CE   O   Container 

Height/Diameter/Delta Units    

21   20   NM   O   Container Volume      22   20   NM   O   Available Specimen Volume      23   20   NM   O   Initial Specimen Volume      24   250   CE   O   Volume Units      25   250   CE   O   Separator Type      26   250   CE   O   Cap Type      27   250   CWE   O   Additive      

Page 36: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 28   250   CE   O   Specimen Component      29   20   SN   O   Dilution Factor      30   250   CE   O   Treatment      31   20   SN   O   Temperature      32   20   NM   O   Hemolysis Index      33   250   CE   O   Hemolysis Index Units      34   20   NM   O   Lipemia Index      35   250   CE   O   Lipemia Index Units      36   20   NM   O   Icterus Index      37   250   CE   O   Icterus Index Units      38   20   NM   O   Fibrin Index      39   250   CE   O   Fibrin Index Units      40   250   CE   O   System Induced 

Contaminants     

41   250   CE   O   Drug Interference      42   250   CE   O   Artificial Blood      43   250   CWE   O   Special Handling Code      44   250   CE   O   Other Environmental Factors      

SPM–SpecimenSegment

SEQ Len DT OPT ElementName CortexLocation Comment1   4   SI   O   Set ID – SPM      2   80   EIP   O   Specimen ID      3   80   EIP   O   Specimen Parent IDs      4   250   CWE   R   Specimen Type      5   250   CWE   O   Specimen Type Modifier      6   250   CWE   O   Specimen Additives      7   250   CWE   O   Specimen Collection 

Method     

8   250   CWE   O   Specimen Source Site      9   250   CWE   O   Specimen Source Site     

Page 37: [HL7 INTERFACE SPECIFICATION] - cortexmed.com · HL7 Minimal Lower ... ADT – Process patient demographic information communicated from a hospital or physician ’s ... [HL7 INTERFACE

[HL7 INTERFACE SPECIFICATION] July 8, 2011 

 Modifier  

10   250   CWE   O   Specimen Collection Site      11   250   CWE   O   Specimen Role      12   20   CQ   O   Specimen Collection 

Amount     

13   6   NM   C   Grouped Specimen Count      14   250   ST   O   Specimen Description      15   250   CWE   O   Specimen Handling Code      16   250   CWE   O   Specimen Risk Code      17   26   DR   O   Specimen Collection 

Date/Time     

18   26   TS   O   Specimen Received Date/Time  

   

19   26   TS   O   Specimen Expiration Date/Time  

   

20   1   ID   O   Specimen Availability      21   250   CWE   O   Specimen Reject Reason      22   250   CWE   O   Specimen Quality      23   250   CWE   O   Specimen Appropriateness      24   250   CWE   O   Specimen Condition      25   20   CQ   O   Specimen Current Quantity      26   4   NM   O   Number of Specimen 

Containers     

27   250   CWE   O   Container Type      28   250   CWE   O   Container Condition      29   250   CWE   O   Specimen Child Role      


Recommended