  • 8/16/2019 Hospital Vent

    1/48

    COMPONENTS FOR MEDICAL PREMISES

    AND SURGERIES IMPLEMENTATION

    medical

    HEALTH CARE

  • 8/16/2019 Hospital Vent

    2/48

  • 8/16/2019 Hospital Vent

    3/48

       P    r   t      t     o  n  p    n  e   l   b   a   s   i   c

    Cat.No. 102.01 B

    PaRTiTiON PaNEL

    The product has been cert if ied in EU countr ies.

    basic

    In the premises established by the partition panels overpressure

    or urderpressure maintaining is guaranteed due to their tight

    connection between the panels, floor, and ceiling, which fact

    meets the basic criteria for cleanrooms for which these panels

    have been specially designed and verified in practical operation.

    COMPONENTS FOR MEDICAL PREMISES

    AND SURGERIE S IMPLEMENTATIONmedical

    The basic partition panels

    represent one of the basic

    elements for the construc-

    tion of cleanrooms and

    workplaces with maximum

    safety, sterility, hygiene,

    simple maintenance, and

    sanitation.

    Due to their design

    they are mainly suitable

    for hospitals, pharmaceu-

    tical, electrical, enginee-

    ring, foodstuff, and chemi-

    cal industry premises.

  • 8/16/2019 Hospital Vent

    4/48

    Colour shadeand materialof the coat

    two-side zinc-coated steel sheet, surface treated, protected by PE foil,

    standard colour: RAL 9010, 9002, 6027 or 1015

    two-side zinc-coated steel sheet, surface treated, colour to order

    AISI 304 FIN 8 stainless steel sheet, protected by PE foil

    zinc-coated sheet (HVAC panels)

    mutual combination of the above designs

    Prole types

    for xing the panels tothe oor

     „Basic“- type prole

     „U“- type prole, with Al cavetto„U“- type prole

    Side-type ending Ending to be specied together with a seller

    Lower-type ending Ending to be specied together with a seller

    Bottom-type ending Ending to be specied together with a seller

    Side reinforcement

    left

    right

    no reinforcement

    Bushings

    from the left side number and distance from the partition edge to be determined

    from the right side number and distance from the partition edge to be determined

    no bushing

    Openingrequired dimension, number, and placing to be specied

    no opening

    BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    102.01 B PARTITION PANEL BASIC

    ANCHORING AND INSTALLATION

    DESCRIPTION 

    THE PANELS

    • Sandwich type, consisting of external coat

    and optional material fill

    • Connected by mutual slipping over, self-supporting

    • Full or glazed by indoor pharma-glazing

    ( t h e g l a z i n g , s e e C a t . N o . 1 0 3 )

    • Above-the-door panel 

    • At-the-door panel 

    • Installation panel for the media distribution lead,

    as a standard, from the floor or from above soffit.

    Installation column, width 200÷400 mm

    • May be completed with bushings for electric feeders

    • May be provided with HVAC grids

    ALL SHAPES AND DESIGNS OF THE BASIC PARTITION PANELSMEET PARAMETERS REQUIRED FOR EXPLOSIVE ENVIRONMENT

    TECHNICAL DATA

    OPTIONAL ELEMENTS

    ACCESORY AND RELATED PRODUCTS

    Cat.no. 103 Partition wall glazing

    Cat.no. 102.02 Fire-resistant panels

    FILLS OF THE PARTITION PANELS

    ADVANTAGES OF THE PARTITION PANELS•  quick installation and dismantling to enable  flexible space layout change•  simple maintenance•  long-lasting appearance•  anti-corrosion protection•  thermal and sound insulation

    Thickness[mm]

    Preferredheight [mm]

    Max. **panelheight [mm]

    Standard width ***[mm]

    Weight/surface ratio in relation to the ll [kg/m2]

    PSE-SF Styrofoam IB Mineral wool

    60 / 62*/

    2550, 2750,3050

     4200 1190, 640, 830

    13.7 14.3 18.5

    80 / 82*/ 14.0 14.8 20.5

    100 / 102*/ 14.4 15.4 22.5

    120 / 122*/ 14.8 16.0 24.5

    *** Panels with a different width are to be made as atypic al, max. panel width 1190mm

    FillThickness

    [mm]Density[kg/m3]

    Max. loadtemperature [°C]

    Thermal conductivityfactor K [W/m.K]

    Flammability

    PSE-SF 58, 78, 98, 118 18 +70 0.0365 B

    Styrofoam IB 60, 80, 100, 120 28 +75 0.035 C1

    Mineral wool 58, 78, 98, 118 100, 150 +900 0.040 B

    Coat

    Fill

    „BASIC“- type profile

         B     P

        •     0     6

       •     0     2

    ** For higher walls, the panels are assembled as for height to reach required dimension

    * Panel thickness with the Styrofoam IB fill will be increased by 2 mm

    FIXING THE PANEL TO THE FLOOR

    •  Fixing of the panel to the floor  • slipping over profiles  - either the “Basic” or the „U“-type profiles

    •  Panel fixed, above soffit, to the constructionceiling or auxiliary structure

      • according to space layout requirementsand interacting with other componentsof an implemented building, by means

    of the „U“- type profile

    „BASIC“- type profile

    „U“- type profile

    „U“- type profile, with Al cavetto

    Cement

    PVC floor

    Underlay profil

    Cement

    Al cavetto

    Poured floor

    MAINTENANCE AND CLEANING

    To be cleaned by non-abrasive disinfecting cleaning

    agents, or by slightly abrasive disifecting cleaning

    agents (applicable only for the ground/matt surfaces,

    only in the grinding direction) based on butyl alcohol(stains, fingerprints); based on acids where heavier

    pollution occurs (mineral sediments, corrosion due

    to HCl).

    Concentration to be chosen in relation to the

    pollution extent.

    „U“- type profile

    Cat.no. 102.05 Soundproofng panels

    Coat„U“- type profile

    medical

  • 8/16/2019 Hospital Vent

    5/48

       F

       i  r  e  -  r  e  s   i  s   t  a  n   t  p  a  r   t   i   t   i  o  n  w  a   l   l  p  a  n  e   l  Cat. No. 102.02 B

    FIRE-RESISTANT PARTITION WALL PANEL

    The fire-resistant pa-

    nels are sandwich

    type; they consist

    of a coat and insi-

    de fil l. Mineral wool

    has been used as the

    panel fil l.

    For electrical feeders,

    electrical bushings

    may be installed

    in the panel fil l.

    The fire-resistant par-

    tition walls are desig-

    ned in the EI15/EW30

    fire resistance.

    The guaranteed pa-

    nels fire resistance,

    complying with rele-

    vant regulations, has

    been tested in a natio-

    nal test facility.

    The product has been certified in EU countries.

    EI15 / EW30 FIRE RESISTANCE

    COMPONENTS FOR MEDICAL PREMISES

    AND SURGERIES I MPLEMENTATIONmedical

  • 8/16/2019 Hospital Vent

    6/48

    102.02B FIRE-RESISTANT PARTITION WALL PANEL

    EI15/EW30 FIRE-RESISTANT PANEL

    Basic partition wall panels with a specific connection system

    Minimum panel thickness - 60 mm• Coat - face, rear• Fill - mineral wool of min. density

    100 kg/m3

    • Fire-resistant protection sheet• Metal bushings for el. feeders

    BEING CONDUCTIVELY INTERCONNECTED, THE FIRE-RESIS-TANT PARTITION WALL PANELS MAY BE USED IN EXPLOSIVEENVIRONMENT, ZONE II

         B     P

        •     0     6

       •     0     8

    DESCRIPTION

    FIXING OF THE PANEL TO THE FLOOR

    FIRE RESISTANCE

    INSTALLATIONInstallation and possible dismantling shallbe carried out exclusively by a company autho-rised to do so.

    EI15/EW30 PANEL

    ** Panels of different width must be produced as atypical (max. panel width is 1,190 mm)

    EI15/EW30 FIRE-RESISTANT PANELS - TECHNICAL DATA

    Thickness[mm]

    Height*[mm]

    Standard width[mm]**

    EI-type fireresistance [min]

    Area weight[kg/m2]

    60 max. 4200 640, 1190 15 18.5

    EI15/EW30 FIRE-RESISTANT PANELS - MINERAL WOOL FILL

    FillThickness

    [mm]Density[kg/m3]

    Maximumloading tem-perature (ºC)

    Thermal con-ductivity factor

    K (W/m.K)Flammability

    Nobasil 58 100, 150 +900 0.040 B

    Conrock 58 100 +1000 0.040 A

    OPTIONAL ELEMENTS

    Colour shade

    and material

     of the

    - face side

      - rear side

    two-side zinc-coated steel sheet, surface treated, protected

    by PE foil, standard colour RAL 9010, 9002, 6027, and 1015

    two-side zinc-coated steel sheet, surface treated, protected

    by PE foil, colour to order

    stainless steel sheet, AISI 304 FIN 8, protected by PE foil

    zinc-coated sheet (HVAC panels)

    mutual combination of the above specified items

    Side ending ending to be specified together with a seller

    Bottom ending ending to be specified together with a seller

    Top ending ending to be specified together with a seller

    Side strut

    simple strut - right-side, left-side

    strut with a fire resistant facing - right-side, left-side

    no strut

    Bushing from right side

    number and distance from

    the edge to be determined

    no bushing

    EI15/EW30 

    • 15 minutes for the panel thickness 60 mm

    * Preferred height - 2,500; 2,750; 3,050 mm

    MAINTENANCE AND CLEANING

    To be washed by non-abrasive disinfecting cleaning

    agents, or by slightly abrasive disinfecting cleaning

    agents (for ground/matt surface only; always clean

    in the grind direction) based on butyl alcohol

    (stains, fingerprints); based on acids where heavier

    pollution occurs (mineral sediments, corrosion due

    to HCl).

    Concentration to be selected in relation to the pollu-

    tion extent.

    ADVANTAGES OF THE PARTITION WALL PANELS

    • Quick installation and dismantling to enable  flexible space layout change.• Simple maintenance• Long-lasting appearance

    • Anti-corrosion protection• Thermal and sound insulation

    Electrical bushing

    Fill

    Fire-resistantprotectionsheet Coat

    Slip-over direction

    ACCESSORIES AND RELATED PRODUCTS

    Cat. No. 104.05 Fire-resistant door 

    Panel

    PVC oor

    Cement

    Underlay rubber proleProle

    medical

    BLOCK a.s., Stulíková 1392, 198 00 Praha 9, Czech Republic, tel.: +420 571 670 111, e-mail: [email protected], www.block.cz

  • 8/16/2019 Hospital Vent

    7/48

       P   l  a  s   t  e  r   b  o  a  r   d   f  a  c   i  n  g  p  a  n  e   l

    Cat. No. 102.03 B Cat. No. 102.01 B

    PLASTERBOARD FACING PANEL

    Together with the partition

    panel system, the plaster-

    board panel represents

    one of the basic elements

    for building cleanrooms and

    facilities with maximum pos-

    sible safety, sterility, hygie-

    ne, simple maintenanceand sanitation.

    It is used for facing of exi-

    sting walls of a building. Its

    advantage is the simplicity,

    quick installation and dis-

    mantling, price and small

    thickness.

    PARTITION WALL

    FACING PANEL

    The panel is of sandwich

    type, consisting of a coat

    and inside fill of various

    variants, with the thi ckness

    32 mm.

       P  a  r   t   i   t   i  o  n  w  a   l   l   f  a  c   i  n  g  p  a  n  e   l

    The product has been cert if ied in EU countr ies.

    Top anchoring Bottom anchoring

    medical COMPONENTS FOR MEDICAL PREMISESAND SURGERIE S IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    8/48

    Panel thickness[mm]

    Height[mm]

    Standard width*[mm]

    Weight[kg/m2]

    C B A

    19 2350, 2550, 3000 640 14

    19 2350, 2550, 3000 1190 20

    BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    102.03 B PLASTERBOARD FACING PANEL

         B     P

        •     0     6

       •     0     6

    BASIC DIMENSION LINE - PLASTERBOARD FACING PANEL CONNECTION OF THE PANELS - SLIPPING OVER

    FIXING OF THE FACING PANEL

    102.01 B PARTITION WALL FACING PANEL

    FILL OF THE PARTITION WALL FACING PANEL

    DESCRIPTION

    OPTIONAL ELEMENTS OF THE PARTITION WALL FACING PANEL

    * Panels of different widths must be produced as atypical (max. panel width is 1,190 mm).BASIC DIMENSION LINE - PLASTERBOARD FACING WALL PANEL

    PLASTERBOARD FACING PANEL

    PARTITION WALL FACING PANEL

    PARTITION WALL FACING PANELPLASTERBOARD FACING PANEL

    Panel thickness[mm]

    Height[mm]

    Standard width*[mm]

    Weight[kg/m2]

    C B A

    32 max. 4200 1190, 640 according to the used ll

    • One coat (fair-face)- optional colour and material

    • Pasted-in plasterboard

    (15 mm thick)

    •  Anchored into floor

    - by means of a guide

    profile

    • Coat (fair-face) - optional colour and material

    • Fill 

    - optional material

    • Struts

    • Coat (rear)

    - zinc-coated sheet

    • Anchoring into floor

      - by means

    of a guide profileFair-face coat

    Fair-facecoat

    Plasterboard

    Fill Thickness[mm]

    Density[kg/m3]

    Max. loadingtemperature

    [C°]

    Thermal conductivityfactor K [W/m.K]

    Flamma-bility

    PSE-SF 30 18 +70 0.0365 B

    Styrofoam IB 30 28 +75 0.035 C1

    Nobasil 30 100, 150 +900 0.040 A

    Conrock 30 100 +1000 0.040 B

    Colourand material ofthe fair-face coat

    two-side zinc-coated steel sheet, surface treated, protected by PE foil,

    standard colours RAL 9010, 9002, 6027 a 1015two-side zinc-coated steel sheet, surface treated, colour to order

    stainless steel sheet, AISI 304 FIN 8, protected by PE foil

    mutual combination of the above specied items

    Fill

    PSE-SF - foam polystyrene, self-extinguishing, in compliance with DIN 18164

    Styrofoam IB - extruded polystyrene foam with good mechanical strength

    Conrock - felt with thermal, sound, and re insulation (mineral wool)

    Nobasil - felt with thermal, sound, and re insulation (mineral wool)

    MAINTENANCE AND CLEANING

    To be washed by non-abrasive disinfecting cl eaning

    agents, or by slightly abrasive disinfecting cleaning

    agents based on butyl alcohol (stains, fingerprints);

    based on acids where heavier pollution occurs

    (mineral sediments, corrosion due to HCl).

    Concentration to be selected in relation to the pollu-

    tion extent.

    PVC

    FACINGPANELExisting

    wall

    Bottomguideprofile

    Topguideprofile

    Floor

    OPTIONAL ELEMENTS OF THE PLASTERBOARD FACING PANEL

    Colourand material ofthe fair-face coat

    zinc-coated sheet, MYRIAD, colour RAL 9010

    zinc-coated sheet, MYRIAD, colour RAL 9002, 6027, 1015

    stainless steel, AISI 304, FIN8 grind

    zinc-coated sheet

    Komaxit of RAL colour

    C

    B

    A

    B

    A

    C

    * Panels of different widths must be produced as atypical (max. panel width is 1,190 mm).

    Coat, rear

    Struts

    Fill

    medical

  • 8/16/2019 Hospital Vent

    9/48

       W   i  n   d  o  w      n  e   l  -   p   h   a   r   m   a  -   t  y    e  g   l    z   i  n  g

       G   l    z   i  n  g   i  n   t  o     l    s   t  e     b  o       d         t   i   t   i  o  n  w     l   l  sCat.No. 103.01 B 103.06 B

    WINDOW paNEL - pharma-TYpE GLaZING

    Together with the partition

    wall system, the fully gla-

    zed window panel represent

    one of the basic elementsfor the construction of clean-

    rooms and facilities with

    maximum safety, sterility,

    hygiene, simple maintenance

    and sanitation.

    In question is the PHARMA

    -type glazing, i.e. the two-sided

    glazing, where the glassplates are flush with the pa-

    nel surface. Due to its

    layout it is suitable, first of

    all, for hospitals, for phar-

    maceutical, electrical, engi-

    neering, and foodstuff in-

    dustry facilities etc.

    aLONG ThE WhOLE paNEL LENGTh

    GLaZING INTO pLaSTErBOarD

    parTITION WaLLS

    The product has been certified in EU countries.

    medical COMPONENTS FOR MEDICAL PREMISESAND SURGERIE S IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    10/48BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    103.01 B WINDOW PANEL - PHARMA-TYPE GLAZING

         B     P

        •     0     6

       •     0     6

    TECHNICAL PARAMETERS OF THE PHARMA - TYPE GLAZING ADVANTAGES OF THE WINDOW PANELS

    CONNECTION OF THE PLASTERBOARD WITH THE GLAZING

    103.06 B GLAZING INTO PLASTERBOARD PARTITION WALLS

    Partition panel(Cat. No. 102.01)

    Glazing

    Plasterboard

    Glass

    * operated from one side only

    ACCESSORY AND RELATED PRODUCTS

    Ct.No. 102.01 Prtton pnel - basiC 

    Ct.No. 102.03 Fcng pnel

    Ct.No. 105 soft

    Ct.No. 107 Lght ttng

    TECHNICAL PARAMETERS OF THE GLAZING INTO PLASTERBOARD PANELS

    WINDOW PANEL - PHARMA - TYPE GLAZING FOR THE WHOLE PANEL WIDTH

    • Quick installation and dismantling, ena-

    bling flexible change of the spatial layout.

    • The system of the window panels con-

    nection is identical with the installation

    system of standa rd partitions, i.e. by means

    of mutual slip-over.

    • The window panel flush with the both

    surface sides of other partition panels.

    A

    B

    C

    Glazing

    Plasterboard

    A

    B

    C

    OPTIONAL ELEMENTS POSSIBLE OPTION STANDARD OPTION

    Width [mm] min. 640 - max. 1190 1190

    Height [mm] min. 800 - max. 1500 1200, 1500

    Thickness [mm] min. 60 - max. 120 60

    Glazing typeoat glass, thick. 4 mm

    foat glass, thick. 4 mmsafety laminated glass, thick. 6 mm

    Sun-blind

    mechanical

    without sun-blindsmagnetic*

    without sun-blinds

    Window frame material steel, class 11 steel, class 11

    Surface treatmentof the window frame

    RAL 9010, 9002, 6027, 1015 metal sheet,colour RAL 9010AISI 304, FIN8 grind

    A

    B

    C

    CONNECTION OF TWO GLAZINGS

    CONNECTION OF THE GLAZINGWITH THE PANEL

    Glass

    Glass

    Glass

    Cementing

    Electrical bushing

    Partition panel

    OPTIONAL ELEMENTS POSSIBLE OPTION STANDARD OPTION

    Width [mm] A   min 640 - max. 1500 1000, 1200

    Height [mm] B   min 800 - max. 1500 1200, 1500

    Thickness [mm] C   min. 75 - max. 150 100, 120

    Glazing typeoat glass, thick. 4 mm

    oat glass, thick. 4 mmsafety laminated glass, thick. 6 mm

    Window frame material steel, class 11 steel, class 11

    Surface treatmentof the window frame RAL 9010, 9002, 6027, 1015 metal sheet,colour RAL 9010AISI 304, FIN8 grind

    GLAZING INTO PLASTERBOARD PANELS

    MAINTENANCE AND CLEANING OF THE BOTH GLAZING TYPES

    • Glass may not be cleaned by acids, thinners, and by other chemical agents thatmay affect the protection silicon layer between a glass plate and a glazing molding.

    • Upon a larger-scale integrity damage of the protection silicon layer it is necessaryto consult the defect removal with the manufacturer.

    • Upon a glass crack, glass is exchanged exclusively by a company authorised bythe manufacturer.

    • Any check on the installed glazing is inadmissible.

    • To secure the quality of the surface treatment, the installed glazing may not be

    subject to air humidity, in an object, higher than 60 %.

    Glass

    Electrical bushing

    Cementing

    Plasterboard

    Glass

    medical

  • 8/16/2019 Hospital Vent

    11/48

       M  e   t  a   l  p  a  r   t   i   t   i  o  n  w  a   l   l

      a   d   d   i   t   i  o  n  a   l  g   l  a  z   i  n  g

    Cat. No. 103.02B Cat. No. 103.03 B

    METAL PARTITION WALL ADDITIONAL GLAZING

    This glazing type is inserted into the existing parti-

    tion wall panels, thickness 60, 80, 100, and 120 mm.

    The window consists of a stiffening profile, cover

    frames, and a sheet glass, 4 or 6 mm thi ck.

    ONE-SIDED, TWO-SIDED

    The product has been certified in EU countries.

    medical COMPONENTS FOR MEDICAL PREMISESAND SURGERIES IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    12/48

    Note:Maximum dimensions of the construction opening are 1,500 x 1,800 mm! – the glazingmust be installed through two panels. This is an atypical product; it is always advanta-geous to consult the producer directly.

    BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    103.02B 103.03B METAL PARTITION WALL ADDITIONAL GLAZING

    METAL PARTITION WALL ADDITIONAL GLAZING

    Type - one-sided (Cat. No. 103.03) - two-sided (Cat. No. 103.02)

    • Glazing  clear glass as a standard, milk glass an atypical

    • Panel thickness [mm]60, 80, 100, 120

      - the panel with Styrofoam IB fill is by 2 mm more thick

    • Panel weight, thickness 60 mm, (80 mm)

      One-sided glazing - 21.4 kg/m2, (22.4 kg/m2)

      Two-sided glazing - 37.4 kg/m

    2

    , (38.4 kg/m

    2

    )

         B     P

        •     0     6

       •     0     8

    ONE-SIDED ADDITIONAL GLAZING

    DESCRIPTION

    ACCESSORY AND RELATED PRODUCTS

    Cat. No. 102.01 Basic partition wall panels

    DESCRIPTION

    Optional elements Possible design Standard design

    Width* [mm] 600, 800, 1000 800, 1000

    Height* [mm] min. 800 - max. 1500 1200, 1500

    Panel thicknessH [mm] min. 60 - max. 120 60

    Glazing typefloat glass, thick. 4 mm

    float glass, thick. 4 mmsafety laminated glass, thick. 6 mm

    Colour shadeand material

    of the cover frame

    RAL 9010, 9002, 6027, 1015RAL 9010

    Stainless steel, AISI 304, FIN8 grind

    TWO-SIDED ADDITIONAL GLAZING

    Optional elements Possible design Standard design

    Width* [mm] 600, 800, 1000 800, 1000

    Height* [mm] min. 800 - max. 1500 1200, 1500

    Panel thickness [mm] min. 60 - max. 120 60

    Glazing typefloat glass, thick. 4 mm

    safety laminated glass, thick. 6 mmfloat glass, thick. 4 mm

    Sun-blinds

    mechanical sun-blinds

    without sun-blindsmagnetic sun-blinds **

    without sun-blinds

    Colour shadeand material

    of the cover frame

    RAL 9010, 9002, 6027, 1015

    Stainless steel, AISI 304, FIN8 grindRAL 9010

    ** operated from one side only

    DIMENSION LINE

    Recommended dimen-sions of the construc-tion opening [mm]

    Glazing size [mm]

       O   n   e

      -   s    i    d   e    d   g    l   a   z    i   n   g

    600 x 1200 548 x 1148

    600 x 1500 548 x 1448

    800 x 1200 748 x 1148

    800 x 1500 748 x 1448

    1000 x 1200 948 x 1148

    1000 x 1500 948 x 1448

       T   w   o  -   s

        i    d   e    d   g    l   a   z    i   n   g

    600 x 1200 548 x 1148

    600 x 1500 548 x 1448

    800 x 1200 748 x 1148

    800 x 1500 748 x 1448

    1000 x 1200 948 x 1148

    1000 x 1500 948 x 1448

    INSTALLATION

    Installation and possible dismantling shall becarried out exclusively by a company authori-sed to do so.

    TWO-SIDED ADDITIONAL GLAZING

    ONE-SIDED ADDITIONAL GLAZING

    A

    A

    B

    H

    B

    H

    Metalpartitionwall panel

    Prole

    CoverframeGlass

    Cementing

    A

    BH

    A

    B

    H

    Note:

    Standard dimensions in bold letters.

    * construction opening A x B

    * construction opening A x B

    Metalpartitionwall panel

    Prole

    Coverframe

    Glass

    Cementing

    medical

  • 8/16/2019 Hospital Vent

    13/48

       T  u  r  n     n  g

       d  o  o  r   b   a   s   i   c

    Cat.No. 104.01 C

    TURNiNG DOOR

    Together with the door-

    frame, the metal turning

    door is one of the basic

    elements for the building

    of cleanrooms and work-

    places with maximum

    safety, sterility, hygiene,

    simple maintenance, and

    sanitation.

    The door wing coat con-

    sists of a formed panel

    made by the precise

    forming method. Along

    the coat perimeter, braces

    are cemented to increase

    the door wing solidity,

    hinge and lock fixing. The

    coat, brace and fill are

    mutually cemented under

    pressure.

    The product has been cert if ied in EU countr ies.

    basic

    The door wing is either full or glazed by the PHARMA

    system, which is a both sided glazing where glass plate

    is flush with the door wing surface. The space between

    the glass plates may be provided with sun-blinds.

    COMPONENTS FOR MEDICAL PREMISES

    AND SURGERIE S IMPLEMENTATIONmedical

  • 8/16/2019 Hospital Vent

    14/48BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    104.01 C

    ACCESSORIES

    BASIC TECHNICAL DATA

    Clear width[mm]

    single-wing min. 600 - max. 1200

    double-wing min. 1200 - max. 2200, active wing min. 600 - max. 1100

    Clear height[mm]

    single-wing min. 1550 - max. 2400

    double-wing min. 1550 - max. 2400

    Door thickness [mm] (standard) 52 (standard), 60

    Coat materialand colour shade

    zinc-coated steel sheet, colour 9010 (standard), protected by PE foil

    zinc-coated steel sheet, colour 9010, 6027, 1015, protected by PE foil

    AISI 304 stainless steel, FIN8 grind, protected by PE foilzinc-coated sheet, protected by PE foil

    Komaxit, RAL colour, protected by PE foil

    Orientationand design

    single-wing Left, right

    double-wingLeft, right

    Left, right, with above-standard control of the xed wing

    Hinge typeHäfele AISI

    Dr. Hahn, RAL 9006, matt, as a standard colour

    TURNING DOOR BASIC

    Glazing

    full, with no glazing

    standard glazing 320x1050 mm

    glazing 1/3 ( S*- 276 mm) x 551 mm

    glazing 1/2 ( S*- 276 mm) x 901 mm

    glazing 2/3 ( S*- 276 mm) x 1251 mm

    fully glazed ( S*- 276 mm ) x 1601 mm

    Glazingmaterial

    oat glass, thickness 4 mm

    oat glass, thickness 4 mm - milk glass

    safety glass, laminated, thickness 6mm

    mirror glazing, 2/3 on the hinge sidemirror glazing, 2/3 opposite the hinge side

    Sun-blinds andtheir control

    mechanical sun-blinds

    magnetic sun-blinds

    controls on the hinge side

    controls opposite the hinge side

    controls on the both sides

    no sun-blinds

    Sun-blindcolour shade

    standard sun-blind colour, RAL 9006

    to order, in accordance with the basic RAL scale

    ACCESSORY AND RELATED PRODUCTS

    Cat.No. 109 HVAC grids

    Cat.No. 102 Partition panels     B     P

        •     0     6

       •     0     1Cat.No. 111.02 Signalization into doorframes

    Cat.No. 111.05 Door wing blocking

    door wing

    hinge

    Yale lock

    standardglazing

    door control- door check

    seal rail

    SINGLE-WING DOOR WITH THE Dr. HAHN HINGE DOUBLE-WING DOOR WITH THE HÄFELE HINGE

    Fittings

    OGRO - stainless Zelinger - thermoplastic

    - handle- xed ball- turning ball

    - handle- xed ball

    panic

    other, optional

    supplied without ttings

    Yale lock

    Yale lock standard

    Yale lock - combined lock / one key for more Yale locks

    Yale lock - general key / entry level may be pre-set

    without the Yale lock, opening covered by a stainless blind

    without the Yale lock

    Telescopic seal rail telescopic seal rail, wiping rail, or no rail

    Door control type manual, door check (to be specied), or automatic drive

    Other accessories ofthe door wing

    door wing blocking

    signalization

    HVAC grid

    300x500 [mm]

    300x400 [mm]

    300x300 [mm]

    without an HVAC grid

    Grounding for the I and II zoneswith grounding

    no grounding

    Doorframematerialand colour shade

    two-side zinc-coated steel sheet, surface treated,standard colour: RAL 9006

    two-side zinc-coated steel sheet, surface treated,colour to order

    AISI 304 stainless steel sheet

    Fixing design

    for partition panels

    for wall partitions

    for plasterboard partitions

    Doorframe thickness 60, 80, 100, 120 mm

    DOORFRAME

    MAINTENANCE AND OPERATION

    • Door wing coat and doorframe  - to be cleaned and disinfected by common cleaning  agents, in relat ion to surface treatment

    • Glass door f i l l  - to be cleaned by common cleaning agents for glass fills  - acids, thinners, and other chemicals not to be used

    • Steel door hinges  - for the Häfele hinge, grease to be appl ied and

    possible sett ing of the hinge to be perform ed  (every two months)  - the Dr. Hahn hinges are maintenance-free

    • Door check  - every two months, or upon need, closing speed,  c los ing force to be set by the set t ing sc rews

    • Door with seal ing rai l  - the space in front of the door to be maintained

    clean,  without solid particles that could cause jamming  or damage of the seal ing rai l

    • To secure permanent quality of the surface treatment,

    the steel door, with the RAL design, may not be subject

    to the relative humidity higher than 60 %.

    Mineral woolThickness [mm] Density [kg/m3]

    Thermal conductivityfactor K [W/m.K]

    Flammability

    50 100 0.040 A

    GLAZING AND SUN-BLINDS

    * S = door wing width

    FILL

    STANDARD DIMENSIONS AND MASS PATTERN

    doorframe

    fittings

    lock

    H

    S

    H

    S

    ac tive wing passive wi ng

    Orderdimensions

    Doorframeclear open-ing, width xheight [mm]

    Dimensionsof the build-

    ing opening,width xheight[mm]

    Pass-throughdimensions when

    the door wingopen by 90°

    [mm]

    Door wing weightwith the standard

    glazing[kg]

    activewing*

    active +passive

    activwing

    passivewing

        s      i    n    g      l    e   -    w      i    n    g 700 x 2100 822 x 2162 644 - 41 -

    900 x 2100 1022 x 2162 844 - 48 -

    1100 x 2100 1222 x 2162 1044 - 54 -

          d    o    u      b      l    e   -    w      i    n    g 1300 x 2100 1422 x 2162 644 1189 41 38

    1500 x 2100 1622 x 2162 844 1389 48 38

    1700 x 2100 1822 x 2162 1044 1589 54 38

    * When using the Häfele hinges the straight-through is 10 mm bigger

    medical

  • 8/16/2019 Hospital Vent

    15/48

       F   i  r  e  -  r  e  s   i  s   t  a  n   t   t  u  r  n   i  n  g    d

      o  o  r

    Cat.No. 104.05 B

    FIRE-RESISTANT TURNING DOOR

    The fire-resistant metal

    turning door is, together

    with the metal doorframe,

    one of the basic elements

    for the building of clean-

    rooms and facilities with

    required increased limita-

    tion of fire spread, upon

    maintained maximum steri-

    lity, hygiene and simple

    maintenance.

    The single-wing door is

    provided with a fire-resis-

    tant lock and fire-resistant

    handle. For double-wing

    door, the fixed wing is pro-

    vided with a top and bottom

    door-latch.

    The product has been cert if ied in EU countr ies.

     A door wing may be ful l or glazed, using the PHARMA system,

    which is a both-sided glazing, where the outer glass panel

    is flushed with the door wing surface; the intermediate space

    is fitted with safety fire-resistant glass.

    medical COMPONENTS FOR MEDICAL PREMISESAND SURGERIE S IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    16/48BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    104.05 B

    ACCESSORIES

    BASIC TECHNICAL DATA

    Clear width[mm]

    single-wing min. 700 - max. 1100

    double-wing min. 1400 - max. 2200

    Clear height[mm]

    single-wing min. 1550 - max. 2400

    double-wing min. 1550 - max. 2400

    Door thickness [mm] 52

    Coat materialand colour shade

    zinc-coated sheet, RAL colour, protected by PE foil

    AISI 304 stainless steel, FIN8 grind, protected by PE foil

    Komaxit, RAL colour, protected by PE foil

    Door orientation and design left, rightHinge type Forclean - all-metal hinges for cleanrooms

    Glazing

    full, without glazing

    standard glazing, 320x1050 mm

    glazing to order - the glazing may not exceed 25 % of the door wing surface

    Glazing material• inside - re-resistant glass

    armoured glass, re-resistant

    clear re-resistant

    Material of theoutside glazing

    Float glass - thick. 4 mm

    safety laminated glass - thick. 6 mm

    FIRE-RESISTANT TURNING DOOR

         B     P

        •     0     6

       •     0     2

    door wing

    hinges

    Yale lock

    glazing

    door control

    - door check

    seal rail

    Fittings

    handle, xed ball, turning ball (OGRO - stainless)

    panic

    other, optional

    supplied without ttings

    Yale lock

    Yale lock, standard

    Yale lock - combined lock / one key for more Yale locks

    Yale lock - general key / entry level may be pre-set

    without the Yale lock, opening covered by a stainless blind

    without the Yale lock

    Mutual sealing of the door and doorframe re-resistant sealing tape

    Sealing of the bottom door section telescopic seal rail

    Door control type door check (to be specied)

    Grounding for the I and II zoneswith grounding

    no grounding

    Material andcolour shade ofthe doorframe

    two-side zinc-coated steel sheet, surfacetreated, standard colour: RAL 9006

    two-side zinc-coated steel sheet,surface treated, colour to order

    AISI 304 stainless steel sheet

    Installationinto wall, min. thickness 100 mm

    into porous concrete, min. thickness 150 mm

    Doorframe thickness 100, 120, 150 mm

    DOORFRAME

    MAINTENANCE AND OPERATION

    • Door-wing coat and doorframe  - to be c l eaned and d i s infec ted by common  cleaning agents, in relation to surface treatment

    • Glass door fi l l  - to be cleaned by common cleaning agents

    for glass f i l l s  - acids, thinners, and other chemicals not to b e used

    • Steel door hinges  - grease to be applied and possible setting

    of the hinge to be performed (every two months)

    • Door check  - every two months, or upon need, closing speed,

    closing force to be set by the setting screws

    • Door with sealing rail  - the space in front of the door to be maintained  clean, without sol id part ic les that could cause  jamming or damage of the sealing rail

    • To secure permanent quality of the surface treatment,  the steel door, with the RAL design, may not be subject  to the relative humidity higher than 60%

    Fill typeThickness

    [mm]Density[kg/m3]

    Max. ther-mal load

    temperature[°C]

    Thermalconductivi-ty factor K[W/m.K]

    Flamma-bility*

    Mineralwool

    30 100 +900 0.040 A

    Fire-resist-ant plates I.

    10 800 +1100 0.18 A

    Fire-resistant

    plates II. 10 1150 +1000 0.32 A

    Orderdimensions Doorframeopening,

    width x height[mm]

    Construction

    openingdimensions,

    width x height[mm]

    Pass-through dimensions

    when the door wingopen by 90°

    [mm]

    Door wingweight with

    the standard glazingand ll of

    the re-resistant plate II.[kg]

    active wingactive +passive

    active wing passive wing

        s      i    n    g      l    e   -    w      i    n    g 700 x 2100 822 x 2162 644 - 82 -

    900 x 2100 1022 x 2162 844 - 95 -

    1100 x 2100 1222 x 2162 1044 - 110 -

          d    o    u      b      l    e   -    w      i    n    g 1400 x 2100 1522 x 2162 644 1289 82 80

    1600 x 2100 1722 x 2162 844 1489 95 80

    1800 x 2100 1922 x 2162 1044 1689 110 80

    INSIDE DOOR FILL

    FIRE-RESISTANCE CLASSIFICATION

    STANDARD DIMENSIONS AND WEIGHT EXAMPLES

    doorframe

    fittings

    lock

    Single-wing door, full type EI1 20-C2 / EI

    2 30-C2 / EW 30-C2(1)

    Double-wing door, full type EI1 15-C2 / EI

    2 30-C2 / EW 30-C2

    Single-wing door, partially glazed: Float, thick. 4mm -re-resistant armoured glass - Float, thick. 4 mm EW 30 C2

    Double-wing door, partially glazed: Float, thick. 4mm - armoured glass, re-resistant - Float, thick. 4 mm EW 30 C2

    Single-wing door, partially glazed: Float, thick. 4mm- clear re-resistant - Float, thick. 4 mm EI1 15-C2 / EI2 15-C2 / EW 30-C2

    Double-wing door, partially glazed: Float, thick. 4mm - clear re-resistant - - Float, thick. 4 mm EI1 15-C2 / EI2 15-C2 / EW 30-C2

    Single-wing door, full, hinges on the side ofa thermal load EI1 30-C2

    (2)

    /EI2 30-C2/EW 60-C2Double-wing door, full, hinges on the side ofa thermal load

    EI1 30-C2(2)/EI

    2 45-C2(2)/EW 30-C2(1)

    (1)  The EN 13501-2 standard enables to classify doo rs only as EW 20, EW 30, EW 60.The doors classified in this table meet the integrity criterion (E) as well as the radiation criterionat the same time (W), for the classification time 45 minutes.

    (2)  Does not apply for the fill – FIRER ESISTANT PLATE II. – MINERAL WOOL – FIRERES ISTANT PLATE II.

    *Flammability determined in accordance with Czech standard norm 73 0862: 1983

    H

    S

    ac tive wing passi ve wing

    H

    S

    NOTEEvery installation must be carried out only in compliancewith a project documentation.The installation and possible dismantling of the doorand doorframe shall be carried out exclusively by a com-pany authorised by the manufacturer.

    medical

  • 8/16/2019 Hospital Vent

    17/48

       X  -  r  a  y  s   d  o  o  r

      s   i  n  g   l  e  -  w   i  n  g ,

       d  o  u   b   l  e  -  w   i  n  g

      Cat.No. 104.08 B

    X-RAYS DOOR

    COMPONENTS FOR MEDICAL PREMISES

    AND SURGERIES IMPLEMENTATION

    The product has been cert if ied in EU countr ies.

    SINGLE-WING, DOUBLE-WING

    Together with the doorframe,

    the metal X-rays door is one of

    the basic elements for the buil-

    ding of cleanrooms and work-

    places with protection against

    X-rays radiation.

    The door is sandwich type. The

    door wing coat consists of

    a formed panel made by the pre-

    cise forming method. Along the

    coat perimeter, braces of zinc-

    coated sheet are cemented to

    increase the door wing solidity,

    hinge and lock fixing.

    Mineral wool is used as standard

    fill together with auxiliary plate

    HPS and shielding lead insert,

    which is delivered in thickness

    within 0,4 mm ÷ 3 mm. A part of

    door is also shielded doorframe

    with protection against X-rays

    radiation.

    medical

  • 8/16/2019 Hospital Vent

    18/48

    104.08 B X-RAYS DOOR

    medical

    BLOCK a.s., Stulíková 1392, 198 00 Praha 9, Czech Republic, tel.: +420 571 670 111, e-mail: [email protected], www.block.cz

    ACCESSORIES

    BASIC TECHNICAL DATA

    ACCESSORY AND RELATED PRODUCTS

    Cat.No. 102.08 X-rays partition panels     B     P

        •     0     7

       •     0     5

    Fittingstype OGRO stainless

    handle

    fixed ball

    turning ball

    panic

    stainless blind

    supplied without fittings

    Yale lock

    Yale lock, standard

    Yale lock - combined lock / one key for more Yale locks

    Yale lock - general key / entry level may be pre-set

    without the Yale lock, opening covered by a stainless blind

    without the Yale lock

    Telescopic seal railtelescopic seal rail

    without rail

    Door control type

    manual

    door check (to be specified)

    automatic drive

    Doorframematerialand shade

    two-side zinc-coated steel sheet, surface treated,standard colour RAL 9006

    two-side zinc-coated steel sheet, surface treated,colour RAL 9002, 6027, 1015

    AISI 304 stainless steel sheet, FIN8 grind

    Fixing design

    for partition panels

    for wall partitions

    Doorframethickness

    60, 80, 100, 120 mm

    SHIELDING INSERT

    MAINTENANCE AND OPERATION

    Fill Thickness [mm] Density [kg/m3]Thermal conductivity

    factor K [W/m.K]Flammability

    Mineral wool 50 100 0.040 A

    Shielding Pb insert 0,4 - 3 11340 - -

    FILL

    STANDARDISED DIMENSIONS AND MASS PATTERN

    Order dimension

    Doorframe clearopeningwidth x height

    [mm]

    Dimensions

    of the building openingwidth x height[mm]

    Pass through

    dimensionswhen the doorwing open by 90°

    [mm]

    Weight of door

    wing with leadinsert 2 mm[kg]

        s      i    n    g      l    e   -    w      i    n    g 700 x 2100 820

     x 2160 644 74

    900 x 2100 1020 x 2160 844 91

          d    o    u      b      l    e   -    w      i    n    g 1300 / 700 x 2100 1420 x 2160 1189 74 / 58

    1500 / 900 x 2100 1620 x 2160 1389 91 / 58

    At door wing open by 180º, the pass-through dimensions are the same as doorframe clear opening.

    door wing

    hinge

    Yale lock

    door control

    – door check

    seal rail

    doorframe

    ttings

    lockpassive wing

    H

    S

    active wing

    DOORFRAME

    • Door-wing coat and doorframe

      - to be cleaned and disinfected by common cleaning

    agents, in relation to surface treatment

    • Door check

      - every two months, or upon need, closing speed, closing

    force to be set by the setting screws

    • Door with sealing rail

      - the space in front of the door to be maintained clean,

    without solid particles that could cause jamming

    or damage of the sealing rail

    • To secure permanent quality of the surfacetreatment, the steel door, with the RAL design, maynot be subject to the relative humidity higher than

    60%.

      WARNING:

      Installation and possible dismantling shall be

    carried out exclusively by a company authorised

    to do so.

    *active wing min. 600 - max. 1000

    Optional design Standard design

    Clear widthsingle-wing min. 600 - max. 1000 [mm] 700, 900 [mm]

    double-wing* min. 1200 - max. 2000 [mm] 1500 [mm]

    Clear height Single as wellas double wing min. 1550 - max. 2100 [mm] 2100 [mm]

    Door thickness 52 [mm] 52 [mm]

    Coat material and colour shade

    zinc-coated steel sheet, colourRAL 9010, 9002, 6027, 1015

    protected by PE foilzinc-coated steel sheet,colour RAL 9010 protectedby PE foil

    zinc-coated steel sheet accordingto RAL patternsAISI 304 stainless steel, FIN8grind protected by PE foilmutual combinations of abovementioned

    Orientationand design

    single-wingleft, right left, right

    double-wing

    S

    H

    Shielding lead insert thickness has to be stated by designer

    every time on base of optimalization and radiation limit

    according delegated legislature.

    Cat.No. 103.08 X-rays partition panel glazing

    -0 -0

    -0 -0

    -0 -0

    -0 -0

    +10

    +10

    +10

    +10

    +5

    +5

    +5

    +5

  • 8/16/2019 Hospital Vent

    19/48

       M  e  c   h  a  n   i  c  s   l   i   d   i  n  g   d  o  o  r

       A  u   t  o  m  a   t   i  c  s   l   i   d   i  n  g   d  o  o  r

    Cat.No. 104.21 B Cat.No. 104.22 C

    MECHANIC SLIDING DOOR

    COMPONENTS FOR MEDICAL PREMISES

    AND SURGERIES IMPLEMENTATION

    The product has been cert if ied in EU countr ies.

    SINGLE-WING, DOUBLE-WING

    The sliding door provides

    a wild spectrum of door

    types described by basic

    and additional parameters

    that enable to produce the

    door on the customer’s

    requirements.

    This is produced as one-

    wing or double-wing door.

     Automatic sliding doors

    are a. c. motor powered.

    Motor is operated by

    frequency converter which

    is controlled by micropro-

    cessor and that control

    automatic door faultless-

    ly in each situation with

    emphasis on safety. It is

    possible to control the

    sliding door by means of

    control accessories, inclu-

    ding remote control and

    possibility of connectionto safety system.

    The door wing is either full or glazed by the PHARMA system,

    which is a both sided glazing where glass plate is flush with the door

    wing surface. The space between the glass plates may beprovided with sun-blinds.

    medical

    AUTOMATIC SLIDING DOOR

  • 8/16/2019 Hospital Vent

    20/48

    104.22 C AUTOMATIC SLIDING DOOR

    DESCRIPTION

    SECTIONS

         B     P

        •     0     7

       •     0     5

    medical

    BLOCK a.s., Stulíková 1392, 198 00 Praha 9, Czech Republic, tel.: +420 571 670 111, e-mail: [email protected], www.block.cz

    FILL

    BASIC TECHNICAL DATA

    Glazing

    full, with no glazing

    glazing 1/3

    glazing 1/2

    glazing 2/3

    Glazing material

    cast glass, thickness 4 mm

    cast glass, thickness 4 mm - satin painted glass

    safety glass, laminated, thickness 6mm - clear

    Sun-blindsand their control

    mechanical sun-blinds

    magnetic sun-blinds

    controls on the hinge side

    controls opposite the hinge side

    controls on the both sides

    no sun-blinds

    Sun-blindcolour shade

    standard sun-blind colour, RAL 9006

    to order, in accordance with the basic RAL scale

    GLAZING AND SUN-BLINDS

    DOORFRAME AND FITTINGS

    CONTROL ACCESSORY - 104.22 Automatic sliding door

    WARNING:

    Installation and possible dismantling of sliding door shall be carried out exclusively by a company

    authorised to do so or by company whose specialist was trained in BLOCK a.s

    Fill Thickness [mm] Density [kg/m3]Max. load

    temperature (°C)Thermal conductivity

     factor K [W/m.K]Flammability

    Mineral wool 50 100 +1000 0.040 A

    Optional design Standard design

    Clear width[mm]

    single-wing min. 800 - max. 1000 800, 900, 1000

    single-wing - atype* 1200 1200

    double-wing min. 1200 - max. 2000 1600, 2000

    Clear height [mm] Single as well as doublewing min. 1550 - max. 2400 2100

    Door thickness [mm] 52 52

    Coat material and colour shade

    zinc-coated steel sheet,colour RAL 9010, 9002, 6027, 1015protected by PE foil

    zinc-coated steel sheet, colourRAL 9010 protected by PE foil

    zinc-coated steel sheet accordingto RAL patternsAISI 304 stainless steel, FIN8grind protected by PE foilmutual combinationsof above mentioned

    Orientationand design

    single-wingleft, right left, right

    double-wing

    Doorframeand backstopcolumn materialand colour shade

    zinc-coated steel sheet, colour RAL 9010

    zinc-coated steel sheet, colour 9002, 6027, 1015

    AISI 304 stainless steel sheet, FIN8 grind

    zinc-coated steel sheet, according to RAL scale

    Fixing design

    for partition panels and wall partitions

    without doorframe only with sheeting

    without doorframe

    Doorframe thickness 60, 80, 100, 120 [mm]

    Fittings

    stainless steel handles

    clips FOR CLEAN AISI (only from traversing side)

    clips FOR CLEAN AISI

    without fittings

    Elbow switch

    Large-area wall switch. This is activated by elbow lean againstthe folding surface, hands stay free. This is delivered in some versions– grey plastic design, crash resistant or clear anodised aluminium

    as a standard.

    Proximity switchThis switch is used especially in hospitals where activates automaticdoor by only hand proximity at distance of 10-50 cm (hygienic reasons).This is placed in the height of usual light switch.

    Contact switchSwitch is possible to place approx. 15-20 cm over the floor, and enablesthe automatic door activation after mild tread to rubber top.

    Microwave radar

    By means of detection field this is enable to scan defined area in frontof the door. Microwave sensors differ movement direction „to the sen-sor“ and „from the sensor“. So it is possible to notably reduce openingperiod.

    Switch knob Wall switch is activated by touch.

    Card scannerCard scanner and entry control system can be used also as activatedunit of automatic door system.

    Door wing

      • coat of optional material and surface treatment

    • fill - mineral wool  • optional glazing and glazing dimensions

    • fittings, lock

    Door control

    104.22 Automatic sliding door

      • elbow switch

      • proximity switch

      • contact switch

      • microwave radar

      • switch knob

      • card scanner

    Partition thickness for sliding door installation

      • 60, 80, 100, 120 mm

      • another thick.- it is possible to produce the door as atypical

    * Single-wing door with clear width 1200 mm is designated for hospitals and medical premises, where the sufficient width has to be for trolleysand mobile beds – that is atypical design of door wing. The door can be full or glazed by pharma glazing. This is equipped by Acrovyn protectioncrash rail in the height of 720 mm above the floor as a standard.

    104.21 Mechanic sliding door 104.22 Automatic sliding door

    104.21 B MECHANIC SLIDING DOOR

    2   S   + 3  5   5    m  m  *  

    2   S   + 5   0  0   m  m  *  

    * S = door clear width

    Cover

    Coat I.

    Coat II.

  • 8/16/2019 Hospital Vent

    21/48

       L   i  g   h   t  m  e   t  a   l  s  o   f   f   i   t   F   O   R   C   L   E   A   N

    Cat.No. 105.01 B

    LIGHT METAL SOFFIT FORCLEAN

    The light metal soffit is

    a lowered ceiling struc-

    ture with a hidden sus-

    pension system, desig-

    nated in particular to

    close cleanrooms, facili-

    tating certain pressu-

    res.

     

    The soffit is used in

    pharmaceutical, ele-

    ctrical, foodstuff, che-

    mical, and engineering

    industry premises, as

    well as in civil engi-

    neering. It is suita-

    ble for hospitals and

    laboratories.

    The soffit structure may be fitted with light fittings, glazed

    and service panels, filtration extenders, and various HVAC elements.

    The product has been cert if ied in EU countr ies.

    medical COMPONENTS FOR MEDICAL PREMISESAND SURGERIE S IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    22/48

    Installationheight[mm]

    Suspension systemThreaded

    rod[mm]

    Components that may be used

    Standardpanel

    Servicepanel

    Glazedpanel

    Lighttting

    PUROFIL

    155 - 205 short truss - 125 mm** max. 1000 YES YES YES NO NO

    205 - 550 long truss - 175 mm** max. 1000 YES YES YES YES NO

    550 - 1135 long truss - 175 mm** max. 1000 YES YES YES YES YES

    1135 - 2135* long truss - 175 mm** max. 2000 YES YES YES YES YES

    Types of ceilingpanels

    standard

    offset (height to be specied, when ordered)

    offset, edge-type (height to be specied, when ordered)

    glazed

    service

    Colour shadeand materialof the standard panel

    zinc-coated, painted steel sheet, colour: RAL 9010, 9002, 1015, 6027

    zinc-coated, painted steel sheet, colour to order

    steel stainless sheet, AISI 304, FIN 8 grind

    Ending type of thesoft

    with a cavetto and perimeter trim (length 3m)

    2x with perimeter trim (length 3m)

    Minimum installation height• see the table TECHNICAL DATA

    Anchoring• into concrete ceiling

    steel anchor, M6 with min. bearingcapacity 0.2 kN/pc 

    • into a steal steel structuremetal truss clamps, M6 The installation and commissioningshall be carried out exclusivelyby a company authorised to do so.

    BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    105.01 B LIGHT METAL SOFFIT FORCLEAN

    ANCHORING AND INSTALLATION

    MAINTENANCE

    • Painted surfaces to be cleaned by non -abrasivedisinfecting cleaning agents based on alcohol

    • Stainless surfaces to be cleaned by non-abrasive disinfecting cleaning agents basedon alcohol, or by slightly abrasive disinfectingcleaning agents (only for the ground/mattsurface, always in the gring direction) basedon butyl alcoh ol (stains, fingeprints), or based

    on acids where heavier pollution occurs. Con-centration to be selected in relation to thepollution extent

    • Glass surfaces to be wiped by a fine fabriccombined with cleaning agents based on alco-hol.

    DESCRIPTION

    • BEARING PROFILES (length 3m - extension by means of links)

      are suspended on threaded rods, M6 (1000mm;  2000mm

    - extension by means of links) anchored to a construction ceiling

    or on an auxiliary structure  • Threaded rods span - 1200 mm (max. 1500mm)

    • Bearing profiles span - 1000 mm (max. 2000mm)

    • SNAP-TYPE PROFILES  (length 3m - extension by means of links)

    they are suspended under the bearing profiles by means of

    SNAP-TYPE PROFILE TRUSSES -

      - short truss: 125mm from the soffit level

    - long truss: 175mm from the soffit level

    The snap-type profile trusses are secured against fall off due

    to an excessive overpressure under the soffit.

    • THE SNAP-TYPE PROFILES are fitted with individual

    standard, glazed, service, or offset panels by their “snapping-in”.

    The FORCLEAN - type light metal soffit is fully compatible

    with HVAC EXTENDERS, PUROFIL FILTRATION EXTENDERS,FORCLEAN LIGHT SNAP-TYPE LIGHT FITTINGS.

    TECHNICAL DATA

    OPTIONAL ELEMENTS

    PRESSURE CONDITIONS

    Max. short-term admissible underpressure in the room vs. the tight space above the soft ca 300Pa

    Max. short-term admissible overpressure in the room vs. the tight space above the soft ca 200Pa

    Operation overpressure and underpressure in the room vs. the tight space above the soft 100 Pa

    GLAZED PANEL SERVICE PANELThe GLAZED PANEL facilitates the room lighting by daylight or by a light fitting placed above the soffit. It

    consists of a snap-type panel with an opening and of a bot tom panel with prismatic glass, type BARLO SAN.

    Above the panel a light fitting may be used with the min. shielding IP20 and max. dimensions 600x600mm.

    Apart from screws, the bottom panel is secured by two springs against fall-out. Standard dimensions

    of the glazed panel are 625x625mm.

    The SERVICE PANEL • enables quick access to the space above

      the soffit, when servicing is needed.

    It consists of a snap-type panel with an opening, and of a bot-

    tom panel. Apart from screws, the bottom panel is secured by two

    springs against fall-out. Standard dimensions of the service panel are

    625x625mm.

    * Bigger installation height may be solved by extension of the threaded rods**  The suspension distance between the soffit level and the top edge of the bearing profile

    STANDARD PANELThe STANDARD PANEL • standard basic module

    • Standard dimensions 625x625mm

    • Non-standard dimensions 600x600,1250x625, 1200x620mm

    • Face side surface

    - standard treatment by the RAL 9010 colour

      - non-standard treatment according to the RAL

    colour list, or with the AISI 304 design, FIN8 grind

    • Panel structure

    - metal panels are fixed by snapping into the snap  type panel

    ACCESSORY AND RELATED PRODUCTS

    Cat.No. 107 Light fttings

    Cat.No. 108 Filtration extenders, fltration outlet 

    Cat.No. 109 HVAC extenders and grilles

    Cat.No. 102 Basic partition panels

    Anchoring spot for

    the M6 threaded rods

    Bearingprofile

    Snap-type profiletruss Panel

    Soffit weight approx. 12 kg.m-2

         B     P

        •     0     6

       •     0     1

    Snap-type profile

    medical

  • 8/16/2019 Hospital Vent

    23/48

       T  r  a  n  s   f  e  r   h  a   t  c   h

      Cat. No.106.01 B Cat. No. 106.02 B

    TRANSFER HATCH

    The product has been cert if ied in EU countr ies.

    For a transfer of smaller

    objects and material

    between rooms with di ffe-

    rent cleanliness class

    the transfer hatch

    installed directly into

    a partition wall may be

    used.

    Walls, ceiling and bottom

    of the transfer hatch are

    made of sandwich-type

    panels.

    If laminar flow inside the hatch is needed, HEPA filter

    is fixed to the hatch ceiling provided with an opening.

    To exhaust air from the hatch, the right door is provided

    with a grille in the bottom section. Where a ventilation

    control grille may be installed in the panel, the hatch bot-

    tom consists of a perforated sheet, under which a catch

    basin is placed.

    - with mechanical blocking- with electromagnetic blocking

    - with blocking controlled by electric lock

    medical COMPONENTS FOR MEDICAL PREMISESAND SURGERI ES IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    24/48

    Walls, ceiling, and bottom of the hatch

    • external coat

    - optional material and colour shade  • inside coat

    - optional material and colour shade

      - sandwich-type panels, thickness 52 mm,

    mineral wool ll

    Door frame • steel, class 11, polyamide

    Bearing frame • steel, class 11

    Glazed door • left, right

      • optional glazing type

      • ttings - handle,

    type OGRO, stainless steel

    Blocking • pls. see „Optional elements“

    Signalization • pls. see „Optional elements“ 

    BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    106.01 B 106.02 B TRANSFER HATCH

         B     P

        •     0     6

       •     0     8

    BASIC DIMENSION LINE

    DESCRIPTION

    TRANSFER HATCH WITH HEPA FILTER

    AIR STREAMOPTIONAL ELEMENTS

    Wallpanel

    Clear transfer dimension Recommended design Standard design

    Clear width S  [mm] 600, 800, 1000

    600 x 600 x 600800 x 800 x 800Clear height

    H  [mm] 600, 800, 1000

    Clear depth U  [mm] 600, 800

    External coat colourshade and material

    two-side zinc-coated steel sheet, surface-treated, protected by PE foil,standard colour: RAL 9010, 9002, 6027 and 1015

    stainless steel design, of AISI 304, on customer´s request

    Inside coat colourshade and material

    stainless steel sheet, AISI 304 FIN 8, protected by PE foil

    stainless steel design, of AISI 304, on customer´s request

    Door frames and frames

    powder nish, identical with the partition wall colour shade

    RAL 9010-K3, 9002, 6027, 1015 as a standard

    stainless steel sheet, AISI 304 FIN 8, protected by PE foil

    any other colour shades according to order

    Air stream

    active

    semi-active

    passive

    Blocking

    mechanicalCat. No. 106.01

    no blocking

    electromagneticCat. No 106.02

    controlled by electric lock

    Signalizationalways combined with the electromagnetic blocking

    always with the blocking controlled by the electric lock

    Door wingmax. glazing, door wing the thickness 35 mm

    all-glazed door wing

    Glazingoat glass, thickness 4 mm

    safety laminated glass, thickness 6 mm

    Door openingrst the door from the cleanroomside is referred

    right - left*, right – right

    left - right*, left – left WARNINGInstallation and possible dismantling shall be carriedout exclusively by a company authorised to do so.*for the hatches with mechanical blocking only these variants may be used

    Maximum clear dimension of the hatch[mm]

    Minimum clear dimension of the hatch[mm]

    width x height x depth width x height x depth

    S  x H  x U S  x H  x U

    1000 x 1000 x 1000 400 x 400 x 400

    • ActiveOwn ltered air supply through HEPA lter; air exhaustto the room with a lower cleanliness class.

    • Semi-activeThe hatch is washed by air from the room with highercleanliness class; air is exhausted to the room with a lowercleanliness class.

    • PassiveThe hatch is not provided with HVAC.

    MAINTENANCE AND CLEANING

    • Painted surfaces to be washed by non-abrasive disinfecting cleaning agents basedon alcohol.

    • Stainless surfaces to be washed by non-abra-sive disinfecting cleaning agents, orby slightly abrasive disinfecting cleaningagents (for ground surface only; alwaysclean in the grind direction) based on butylalcohol (stains, fingerprints); based onacids where heavier pollution occurs.

      Concentration to be selected in relation tothe pollution extent.

    • Glass surfaces to be wiped by fine fabriccombined with cleaning agents basedon alcohol.

    Partition wall

    H  + 104 mm

    S  + 104 mm U  + 86 mm

    Doorframe

    Signalization

    Bearing frame

    Glass

    Partitionwall

    H  + 104 mm

    S  + 104 mm U  + 86 mm

    Doorframe

    Mechanicalblocking

    Bearing frameGrille

    Glass

    HEPAfilter

    Electro-

    magneticblocking

    Partitionwall

    medical

  • 8/16/2019 Hospital Vent

    25/48

       F   l  u  o  r   t  u   b  e   l   i  g   h   t      t   t   i  n  g ,   F   O   R   C   L   E   A   N   l   i  g   h   t

       t  o   l   i  g   h   t  m  e   t  a   l  s  o   f      t  –  s  n  a  p  -  o  n   t  y  p  e

    Cat. No. 107.04 A

    FLUOR TUBE LIGHT FITTING, FORCLEAN LIGHT

    The product has been cert if ied in EU countr ies.

    TO LIGHT METAL SOFFIT - SNAp-ON TypE

    The uor tube light t-

    tings, FORCLEAN Light,

    are designated for lighting

    of interior rooms with cont-

    rolled cleanliness classes.

    They are installed into light

    metal softs. They are airtight,

    thus securing the pressure

    tightness of the whole soft.

    The surface treatment and

    light ttings colour shadeare identical with those

    of the soft.

    medical COMPONENTS FOR MEDICAL PREMISESAND SURGERI ES IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    26/48BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    107.04 A

    BASIC DESCRIPTION

    TECHNICAL SPECIFICATION

    OPTIONAL ELEMENTS

    Bottom frame materialand colour shade

    steel sheet, class 11, colour: RAL 9010-K3

    steel sheet, class 11, colour: RAL 9002

    steel sheet, class 11, colour: RAL 1015

    steel sheet, class 11, colour: RAL 6027

    stainless steel, AISI 304, FIN 8 grind

    Optical part solutionprismatic (lenticular)

    clear, with optical raster (grille)

    Compact uortubes colour

    PHILIPS PL-L 830/4P, light colour: warm tone (55 W)

    PHILIPS PL-L 840/4P, light colour: white (55 W)

    no compact uor tubes delivered

    Emergenc power sourceemergenc lighting set, HELP2

    no emergenc power source delivered

    FLUOR TUBE LIGHT FITTING, FORCLEAN LIGHT TO LIGHT METAL SOFFIT - SNAP-ON TyPE

         B     P

        •     0     6

       •     0     8ACCESSORy AND RELATED PRODUCTS

    Cat. No. 105 Light metal soft FORCLEAN Cat. No. 102 Partition wall panel  

    INSTALLATION

    Tpe Bn/O/N Bn/P/N Bn/O Bn/P

    Design Clear, with optical raster(grille) PrismaticClear, with optical raster

    (grille) Prismatic

    Shielding IP 54 IP 54 IP 54 IP 54

    Light source [W] 2x55 2x55 2x55 2x55

    Voltage [V] 230 230 230 230

    Current [A] 1,0 1,0 1,0 1,0

    Dimensions A x B[mm] 625 x 625 625 x 625 625 x 625 625 x 625

    Weight [kg] 8,0 7,8 7,5 7,2

    Illuminating power[lm] 10007,4 10007,4 10007,4 10007,4

    Emergenc source* HELP 2 (18-58W) HELP 2 (18-58W) - -

    MAINTENANCE AND OPERATION

    Prior to any repair and cleaning, power supply

    of the appliance must be disconnected and secu-

    red against accidental switch-on!

    • Under an suspicion in respect of a shielding failure,

    a check of the device, or a shut-down and repair,

    is necessar.

    • Fluor tubes exchange and cleaning of the applian-

    ce must be done onl b a person or service

    organisation authorised to do so.

    Surface cleaning of the light tting

    • Common cleaning agents to be used that do not

    contain abrasive agents.

    Disinfection

    • to be done b common disinfecting agents

    • Connection of the appliance to electric system

    Connection of the appliance to electric sstem,from the building’s side is resolvedb the designer.Terminal board , X1 

    • designed to connect one phase,voltage 23 0 V / 50 Hz

    • scope of possibl applicable cross-sec-tions of connection conductors:

    0.5 mm2 - 1.5 mm2 Distribution system: 1 + N + PE AC / 50 Hz

      Network: TN-S 230 V / 50 Hz

    Master protection system: max 10 A

    Under no circumstances the light tting may be co-

    vered by an insulation pad or by a similar material. 

    WARNING

    The connection of the appliance to electri-

    cal system, of a conductor to the termi-

    nal board and to a terminal, and handling

    with electric installations may be done

    only by a person with a necessary quali-

    fication in respect of works on electrical

    equipment.

    Used abbreviations:

    Bn - dimension line, A x B /625 x 625 mm/ - snap-on tpe O - with clear glass and optical raster

    P - with prismatic raster N - emergenc power source set, HELP

    The radiating angle of a guaranteed luminance for the calculation of an illuminated area:• 45 deg. for the optical raster solution• 50 deg. for the prismatic raster solution

    LUMINANCE RADIATING ANGLE

    *Upon electric system outage, the emergency source will supply the light fitting for at least 1 hour.

      • Light fitting frame- secures its shape stabilit

    • Optical part -  prismatic cover in a metal frame

      - clear plexi-glass in a metal frame with a metal-coatedparabolic grille

    A correct type of its optical part to be determined by a designer for a concrete space.Detail optical/technical specication upon request.

      • Inside equipment

      - compact fluor tubes, caps  - electronic stabiliser  - cabling and connection terminal board  - optional emergenc power source  - batter

    - test button

    The light tting‘s inside space is hermeticall separated from the space above

    the soft b the coat. The suppl cable is lead through a tight bushing, PG11 / IP54.The light tting, type FORCLEAN Light, is fully compatible with the light metal soft (105.01).

    Light ftting with an optical part- clear plexi-glass

    with a parabolic grille

    Light fttingwith an optical part- prismatic cover

    medical

  • 8/16/2019 Hospital Vent

    27/48

       F   i   l   t  r  a   t   i  o  n  e  x   t  e  n   d  e  r  s ,

       t  y  p  e   P   U   R   O   F   I   L

      -   T   Y   P   E   F   N   A

    Cat. No. 108.01 B

    FILTRATION EXTENDERS, TYPE PUROFIL

    with the filter, dimensions: 305 x 305 mm - TYPE FNA

    The extenders are made with several coat dimensions, according

    to filter size. For the supply air distribution, the bottom section

    of the extenders is fitted with whirl outlets or perforated elements.

    The PUROFIL filtration ex-

    tenders are intended to be

    the terminal element of 

    air supply for premises

    with high demands on thecleanness of supplied air,

    like surgeries, sterilisation

    premises, intensive care

    units, premises in the phar-

    maceutical, electrical, engi-

    neering, foodstuff industries,

    etc.

    The product has been certified in EU countries.

    medical COMPONENTS FOR MEDICAL PREMISESAND SURGERIE S IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    28/48

    Raster[mm]

    C  x C

    Filter

    AIR SUPPLY TYPE

    Side circularSide rectangular

    + one-side conversionTop circular

    HEPA H12, Alframe[mm]

    HEPA H13,MDF frame

    [mm]

    HEPA H14,Al frame

    [mm]

    Throatdimen-

    sion[mm]

    Totalheight

    [mm] 

    Heightof

    bottomstructure

    [mm]

    Heightof top

    structure[mm]

    Throatdimen-

    sion[mm]

    Totalheight

    [mm] 

    Heightof

    bottomstructure

    [mm]

    Heightof top

    structure[mm]

    Throatdimen-

    sion[mm]

    Totalheight

    [mm] 

    Heightof

    bottomstructure

    [mm]

    Heightof top

    structure[mm]

    A   x A   x B D H G I E  x F   H G I D H G I

    600x600305x305x78

    Ø160 390 180 210 265x80 290 180 110 Ø160 260 180 80

    625x625* Ø200 430 180 250 265x120 330 180 150 Ø200 260 180 80

    600x600305x305x149

    Ø160 462 252 210 265x80 362 252 110 Ø160 332 252 80

    625x625* Ø200 502 252 250 265x120 402 252 150 Ø200 332 252 80

    600x600305x305x117

    Ø160 427 217 210 265x80 327 217 110 Ø160 297 217 80

    625x625* Ø200 467 217 250 265x120 367 217 150 Ø200 297 217 80

    BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    108.01 B FILTRATION EXTENDERS, TYPE PUROFIL - TYPE FNA

    DESCRIPTION

    STANDARD DIMENSION LINE

    OPTIONAL ELEMENTS FURTHER AIR SUPPLY OPTIONS

         B     P

        •     0     6

       •     0     6

    H

    A

    C

    G

    E

    F

    B

    Installation into softLight metal soft, FORCLEANThermatexMetal panel-type soft

    Type dimensionsof the raster [mm]

    625 x 625 (preferred)600 x 600

    Surface

    of the PUROFIL elementsPowder-type stove enamel, Komaxit, with standard colours,RAL 9010, 9002, 6027, 1015, or stainless steel, AISI 304, FIN 8 grind

    Surface

    of the output elementPowder-type stove enamel, Komaxit, with standard colours,RAL 9010, 9002, 6027, 1015, or stainless steel, AISI 304, FIN 8 grind

    Filter frame material

    Aluminium (for the ltration class H12, H13, H14)

    MDF (for the ltration class H12, H13)

    Output elementWhirling elementWhirling element, densePerforated sheet

    Accessories - one-sideconversions [mm]

    265 x 80 / Ø160265 x 120 / Ø200

    Accessories – probes1 probe as a standard2 probes

    A

    Bottom structure

    Filter

    Top structure

    HVAC flange

    Raster

    Snap-type profile

    * Preferred raster dimensions

    PUROFIL, WITH SIDE RECTANGULAR AIR SUPPLY

    TECHNICAL PARAMETERS

    FILTER DISTRIBUTION ELEMENTMedia height [“] Weight [kg] Flow-rate [m3/hod] Initial pressure drop [Pa] Flow speed [m/s] Whirling, standard Whirling, dense Perforated

    HEPA H12

    Al frame

    305x305x78 [mm]

    1” 3 50 83 0,15 yes no yes

    2” 3 100 91 0,3 yes no yes

    3” 3 150 100 0,45 no yes yes

    HEPA H13

    MDF frame

    305x305x149 [mm]

    1” 4 90 86 0,15 yes no yes

    2” 4 160 94 0,3 no yes yes

    3” 4 220 103 0,45 no yes yes

    4” 4 250 116 0,6 no yes yes

    HEPA H14 Al frame

    305x305x117 [mm]

    1” 3 90 86 0,15 yes no yes

    2” 3 160 94 0,3 no yes yes

    3” 3 220 103 0,45 no yes yes

    4” 3 250 116 0,6 no yes yes

    TOP CIRCULAR

    SIDE CIRCULAR

    D

    D

    C

    I

    PUROFIL

      • Bottom structure

    - secures the shape stability- fitted with the HEPA filter  - contains a distribution element

    (whirl outlets or perforated sheet)• Top structure

    - zinc-coated sheet  - with air supply of the  • side rectangular shape

    • side circular shape• top circular shape

    As a standard, the extenders are provided with one probefor the leakage aerosol tests.

    THE EXTENDER IS FULLY COMPATIBLE WITH THE LIGHT METALSOFFIT (Cat. No. 105).

    medical

  • 8/16/2019 Hospital Vent

    29/48

       F   i   l   t  r  a   t   i  o  n  e  x   t  e  n   d  e  r  s ,

       t  y  p  e   P   U   R   O   F   I   L

      -   T   Y   P   E   F   N   B

    Cat. No. 108.01 B

    FILTRATION EXTENDERS, TYPE PUROFIL

    with the filter, dimensions: 457 x 457 mm - TYPE FNB

    The product has been certified in EU countries.

    The extenders are made with several coat dimensions, according

    to filter size. For the supply air distribution, the bottom section

    of the extenders is fitted with whirl outlets or perforated elements.

    COMPONENTS FOR MEDICAL PREMISES

    AND SURGERIE S IMPLEMENTATIONmedical

    The PUROFIL filtration ex-

    tenders are intended to be

    the terminal element of 

    air supply for premises

    with high demands on thecleanness of supplied air,

    like surgeries, sterilisation

    premises, intensive care

    units, premises in the phar-

    maceutical, electrical, engi-

    neering, foodstuff industries,

    etc.

  • 8/16/2019 Hospital Vent

    30/48

    Raster[mm]

    C  x C

    Filter

    AIR SUPPLY TYPE

    Side circularSide rectangular

    + one-side conversionTop circular

    HEPA H12Al frame

    [mm]

    HEPA H13MDF frame

    [mm]

    HEPA H14Al frame

    [mm]

    Throatdimen-

    sion[mm]

    Totalheight

    [mm] 

    Heightof

    bottomstructure

    [mm]

    Heightof top

    structure[mm]

    Throatdimen-

    sion[mm]

    Totalheight

    [mm] 

    Heightof

    bottomstructure

    [mm]

    Heightof top

    structure[mm]

    Throatdimen-

    sion[mm]

    Totalheight

    [mm] 

    Heightof

    bottomstructure

    [mm]

    Heightof top

    structure[mm]

    A   x A   x B D H G I E  x F   H G I D H G I

    600x600475x457x78

    Ø200 430 180 250 417x80 290 180 110 Ø200 260 180 80

    625x625* Ø250 480 180 300 417x120 330 180 150 Ø250 260 180 80

    600x600475x457x149

    Ø200 502 252 250 417x80 362 252 110 Ø200 332 252 80

    625x625* Ø250 552 252 300 417x120 402 252 150 Ø250 332 252 80

    600x600475x457x117

    Ø200 467 217 250 417x80 327 217 110 Ø200 297 217 80

    625x625* Ø250 517 217 300 417x120 367 217 150 Ø250 297 217 80

    BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    108.01 B FILTRATION EXTENDERS, TYPE PUROFIL - TYPE FNB

    DESCRIPTION

    STANDARD DIMENSION LINE

    OPTIONAL ELEMENTS FURTHER AIR SUPPLY OPTIONS

         B     P

        •     0     6

       •     0     6

    H

    A

    C

    G

    E

    F

    B

    Installation into softLight metal soft, FORCLEANThermatexMetal panel-type soft

    Type dimensionsof the raster [mm]

    625 x 625 (preferred)600 x 600

    Surfaceof the PUROFIL elements

    Powder-type stove enamel, Komaxit, with standard colours,RAL 9010, 9002, 6027, 1015, or stainless steel, AISI 304, FIN 8 grind

    Surfaceof the output element

    Powder-type stove enamel, Komaxit, with standard colours,RAL 9010, 9002, 6027, 1015, or stainless steel, AISI 304, FIN 8 grind

    Filter frame materialAluminium (for the ltration class H12, H13, H14)

    MDF (for the ltration class H12, H13)

    Output element

    Whirling, innovatedWhirling elementWhirling element, densePerforated sheet

    Accessories - one-sideconversions [mm]

    417 x 80 / Ø200417 x 120 / Ø250

    Accessories – probes1 probe as a standard2 probes

    A

    Bottom structure

    Filter

    Top structure

    HVAC flange

    Raster

    Snap-type profile

    * Preferred raster dimensions

    PUROFIL, WITH SIDE RECTANGULAR AIR SUPPLY

    TECHNICAL PARAMETERS

    FILTER DISTRIBUTION ELEMENTMedia height [“] Weight [kg] Flow-rate [m3/hod] Initial pressure drop [Pa] Flow speed [m/s] Whirling, innovated Whirling, standard Whirling, dense Perforated

    HEPA H12

    Al frame

    457x457x78 [mm]

    1” 3,5 100 83 0,15 yes yes no yes

    2” 3,5 220 91 0,3 yes yes no yes

    3” 3,5 330 100 0,45 yes yes yes yes

    HEPA H13

    MDF frame

    457x457x149 [mm]

    1” 4,5 200 86 0,15 yes yes no yes

    2” 4,5 360 94 0,3 yes yes yes yes

    3” 4,5 490 103 0,45 yes no yes yes

    4” 4,5 570 116 0,6 yes no yes yes

    HEPA H14 Al frame

    457x457x117 [mm]

    1” 3,5 200 86 0,15 yes yes no yes

    2” 3,5 360 94 0,3 yes yes yes yes

    3” 3,5 490 103 0,45 yes no yes yes

    4” 3,5 570 116 0,6 yes no yes yes

    TOP CIRCULAR

    SIDE CIRCULAR

    D

    D

    C

    I

    PUROFIL

      • Bottom structure

    - secures the shape stability- fitted with the HEPA filter  - contains a distribution element

    (whirl outlets or perforated sheet)• Top structure

    - zinc-coated sheet  - with air supply of the  • side rectangular shape

    • side circular shape• top circular shape

    As a standard, the extenders are provided with one probefor the leakage aerosol tests.

    THE EXTENDER IS FULLY COMPATIBLE WITH THE LIGHT METALSOFFIT (Cat. No. 105).

    medical

  • 8/16/2019 Hospital Vent

    31/48

       F   i   l   t  r  a   t   i  o  n  e  x   t  e  n   d  e  r  s ,

       t  y  p  e   P   U   R   O   F   I   L

      -   T   Y   P   E   F   N   C

    Cat. no. 108.01 B

    FILTRATION EXTENDERS, TYPE PUROFIL

    with the filter, dimensions: 570 x 570 mm - TYPE FNC

    The product has been certified in EU countries.

    The extenders are made with several coat dimensions, according

    to filter size. For the supply air distribution, the bottom section

    of the extenders is fitted with whirl outlets, perforated elements,

    or with anemostat.

     

    COMPONENTS FOR MEDICAL PREMISES

    AND SURGERIE S IMPLEMENTATIONmedical

    The PUROFIL filtration ex-

    tenders are intended to be

    the terminal element of 

    air supply for premises

    with high demands on thecleanness of supplied air,

    like surgeries, sterilisation

    premises, intensive care

    units, premises in the phar-

    maceutical, electrical, engi-

    neering, foodstuff industries,

    etc.

  • 8/16/2019 Hospital Vent

    32/48

    Raster[mm]

    C  x C

    Filter

    AIR SUPPLY TYPE

    Side circularSide rectangular

    + one-side conversionTop circular

    HEPA H13MDF frame

    [mm]

    HEPA H14Al frame

    [mm]

    Throatdimen-

    sion[mm]

    Totalheight

    [mm] 

    Heightof bottomstructure

    [mm]

    Heightof top

    structure[mm]

    Throatdimension

    [mm]

    Totalheight

    [mm] 

    Heightof bottomstructure

    [mm]

    Heightof top

    structure[mm]

    Throatdimension

    [mm]

    Totalheight

    [mm] 

    Heightof bottomstructure

    [mm]

    Heightof top

    structure[mm]

    A   x A   x B D H G I E  x F   H G I D H G I

    625x625

    570x570x149Ø250 555 255 300 530x95 380 255 125 Ø250 345 255 90

    Ø315 625 255 370 530x145 430 255 175 Ø315 345 255 90

    570x570x117Ø250 520 220 300 530x95 345 220 125 Ø250 310 220 90

    Ø315 590 220 370 530x145 395 220 175 Ø315 310 220 90

    BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    108.01 B FILTRATION EXTENDERS, TYPE PUROFIL - TYPE FNC

    DESCRIPTION

    STANDARD DIMENSION LINE

    OPTIONAL ELEMENTS FURTHER AIR SUPPLY OPTIONS

         B     P

        •     0     6

       •     0     6

    PUROFIL

      • Bottom structure

    - secures the shape stability- fitted with the HEPA filter  - contains a distribution element

    (whirl outlets, perforated sheet or anemostat)• Top structure

    - zinc-coated sheet  - with air supply of the  • side rectangular shape

    • side circular shape• top circular shape

    As a standard, the extenders are provided with one probefor the leakage aerosol tests.

    THE EXTENDER IS FULLY COMPATIBLE WITH THE LIGHT METALSOFFIT (Cat. No. 105).

    H

    A

    C

    G

    E

    F

    B

    Installation into soft

    Light metal soft, FORCLEAN

    Thermatex

    Metal panel-type soft

    Type dimensions of the raster [mm] 625 x 625

    Surfaceof the PUROFIL elements

    Powder-type stove enamel, Komaxit, with standard colours,RAL 9010, 9002, 6027, 1015, or stainless steel, AISI 304, FIN 8 grind

    Surfaceof the output element

    Powder-type stove enamel, Komaxit, with standard colours,RAL 9010, 9002, 6027, 1015, or stainless steel, AISI 304, FIN 8 grind

    Filter frame materialAluminium (for the ltration class H13, H14)

    MDF (for the ltration class H13)

    Output elementWhirling innovated, whirling element, whirling element dense, perforated sheet

    or anemostat

    Accessories - one-sideconversions [mm]

    530x145 / Ø315

    530x95 / Ø251

    Accessories – probes1 probe as a standard

    2 probes

    A

    Bottom structure

    Filter

    Top structure

    HVAC flange

    Raster

    Snap-type profile

    PUROFIL, WITH SIDE RECTANGULAR AIR SUPPLY

    TECHNICAL PARAMETERS

    FILTER DISTRIBUTION ELEMENT

    Media height [“] Weight [kg] Flow-rate [m3/hod] Initial pressure drop [Pa] Flow speed [m/s] Whirl ing, innovated Whirl ing, standard Whirl ing, dense Perforated Anemostat

    HEPA H13

    MDF frame

    570x570x149

    [mm]

    1” 5,5 300 86 0,15 yes yes no yes no

    2” 5,5 560 94 0,3 yes no yes yes yes

    3” 5,5 760 103 0,45 yes no yes yes yes

    4” 5,5 880 116 0,6 yes no no yes yes

    HEPA H14

     Al frame570x570x117

    [mm]

    1” 4,5 300 86 0,15 yes yes no yes no

    2” 4,5 560 94 0,3 yes no yes yes yes3” 4,5 760 103 0,45 yes no yes yes yes

    4” 3,5 880 116 0,6 yes no no yes yes

    TOP CIRCULAR

    SIDE CIRCULAR

    D

    D

    C

    I

    medical

  • 8/16/2019 Hospital Vent

    33/48

       F    i    l   t   r   a   t    i   o   n 

       o   u   t    l   e   t

        f   o   r

       s   u   r   g   e   r    i   e   s

    The filtration outlet is connected to HVAC ducts

    supplying pre-filtered air (at least F7 class in complian-

    ce with Czech standard norm EN 779) of a prescribed

    temperature and relati ve humidity.

    In the fil tration outlet air is treated to reach the required clean-liness (H13 ÷ H14 HEPA filters).

    The filtration outlet

    serves for establishing

    of a uniform air stre-

    am, of a defined clean-

    liness class, in the o-

    peration sector of sep-

    tic, aseptic, and super-

    aseptic surgeries.

    The implementation

    of the filtration outlet

    prevents the operation

    sector from the conta-

    mination by bacteria,

    viruses, and dust par-

    ticles.

    The highest hygienic

    and technical require-

    ments for the air filtra-

    tion are hereby met.

    The product has been cert if ied in EU countr ies.

    FILTRATION OUTLET FOR SURGERIES

    Cat. No. 108.03 A

    medical COMPONENTS FOR MEDICAL PREMISESAND SUR GERIES IMPLEMENTATION

  • 8/16/2019 Hospital Vent

    34/48BLOCK a.s., U Kasáren 727, 757 01 Valašské Meziříčí, tel.: +420 571 670 111, fax: +420 571 670 244, e-mail: [email protected], www.block.cz

    108.03 A FILTRATION OUTLET FOR SURGERIES

    medical

    Illuminationcontrol

    dimming illuminationnon-dimming illumination

    no light ttings

    Lighting(tube types)

    90219 49 W F49W/T5/HO/830, luminous ux 4,900 lm length 1,449 mm

    90223 49 W F49W/T5/HO/840, luminous ux 4,900 lm length 1,449 mm

    no uor tubes

    HEPA ltersH13; H14 - lter frame of Al; lter height 117mm; 4“ medium

    H13 - lter frame of MDF; lter height 130mm; 4“ medium

    Screens

    no screens

    exible screens (length to be laid down - min. 100 mm)

    xed screens (length to be laid down - min. 100 mm)

    antistatic exible screens (length to be laid down - min. 100 mm)

    antistatic xed screens (length to be laid down - min. 100 mm)

    Fixing of the lami-nar ow device

    quick-acting clamps

    threaded connection and riveting nutsTube diameterof the operation lighttting

    125 mm as a standard

    atypical diameter

    TECHNICAL DESCRIPTION

    TECHNICAL PARAMETERS

    Filtrationoutlet

    dimensions[mm]

    Maximum air ow parameters Recommended air ow parameters

    Air owQ

    max 

    [m3/hod]

    InitialΔp

    max[Pa] for 

    the H13/H14

    HEPA lters

    Outputvelocityv

    max[m/s]

    Acousticpressure

    level[dB(A)]*

    Air ow Q[m3/hod]

    InitialΔp

     [Pa] for 

    the H13/H14

    HEPA lters

    Outputvelocityv [m/s]

    Acousticpressure

    level[dB(A)]*

    1875x1875 3797 170/207 0,3 40 2785 150/183 0,22 36

    1875x2500 5062 190/232 0,3 40 3712 170/207 0,22 36

    2500x2500 6750 190/232 0,3 40 4950 170/207 0,22 36

    FILTRATION OUTLET – 1,875 x 1


Recommended