HP Server rp2400 to rp2470 System Upgrade Procedure (A9804A) HP Server rp24xx Edition 1 February 2003 Manufacturing Part Number: N/A
Transcript
Page 1: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

HP Server rp2400 to rp2470 System Upgrade Procedure

(A9804A)

HP Server rp24xx

Edition 1February 2003

Manufacturing Part Number: N/A

Page 2: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

Legal NoticesThe information contained in this document is subject to change without notice.

Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material.

Restricted Rights Legend. Use, duplication or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and (c) (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for other agencies.

HEWLETT-PACKARD COMPANY 3000 Hanover Street Palo Alto, California 94304 U.S.A.

Copyright Notices. Copyright „ 1983-2002 Hewlett-Packard Company, All Rights Reserved.

Reproduction, adaptation, or translation of this document without prior written permission is prohibited, except as allowed under the copyright laws.

Trademark Notices. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company Limited.

NOTE Reader Comments. We welcome your comments about our documentation. If you have editorial suggestions or recommend improvements for this document, please write to us. You can reach us through e-mail at: [email protected] or by sending your letter to: Documentation Manager, M/S 5657, Hewlett-Packard Company, 8000 Foothills Blvd., Roseville, CA 95747-5657 USA. Please include the following information in your message:

• Title of the manual you are referencing.

• Manual part number (from the title page).

• Edition number or publication date (from the title page).

• Your name.

• Your company’s name.

SERIOUS ERRORS, such as technical inaccuracies that may render a program or a hardware device inoperative, should be reported to your HP Response Center or directly to a Support Engineer.

ii

Page 3: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

Contents

1. rp2400 to rp2470 System Upgrade Procedure (A9804A)A6889-67101 System Board Upgrade Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

System Board Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Installing the new System Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Resetting the Software ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8A6891-62001/A6892-62001 Processor Module Upgrade Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

CPU Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10CPU Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Installing the CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12A6889-67102 Guardian Service Processor (GSP) Upgrade Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . 13

GSP Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13GSP Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Guardian Service Processor Firmware Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Configuring the LAN Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

iii

Page 4: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

Contents

iv

Page 5: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)

1 rp2400 to rp2470 System Upgrade Procedure (A9804A)

The steps and procedures included in this document are generic in nature, intended to cover a wide variety of installation/upgrade situations. Installation personnel should use their own judgement in following the steps for each process. Some steps may not be required.

This section provides the procedures for installing the rp2400 to rp2470 (650 or 750 MHz) Upgrade Kit for the rp24xx system. The HP Server rp24xx product set is identified as follows:

Tools required:

• #1 philips screwdriver

• T10 screwdriver

• T15 screwdriver

The rp2400 to rp2470 Upgrade Kit contains:

• One A6889-67101 Upgrade Kit System Board (550, 650, or 750 Mhz capable). GSP is pre-installed.

• One A6889-62002 Terminator Assembly

• One A6144-63001 Cable - M

• One 0950-3821 DC/DC Converter - Master

• One 0950-3822 DC/DC Converter - Slave

• Two A6889-67004 Disc Media Backplane modules

• One or two processor modules:

❏ A6891-62001 650 Mhz processor

Name Product # System Description Model String

HP Server rp2400

A6109A 1-way 440 MHz 9000/800/A400-44

HP Server rp2450

A5570A 1-2 way 440 MHz 9000/800/A500-44

HP Server rp2450

A5570A 1-2 way 550 MHz 9000/800/A500-5X

HP Server rp2430

A6889A 1-way 650 MHz (includes PA-8700 upgrade) 9000/800/A400-6x

HP Server rp2470

A6890A 1-2 way 650 MHz (includes PA-8700 upgrade)

9000/800/A500-6x

HP Server rp2470

A6890A 1-2 way 750 MHz (includes PA-8700 upgrade)

9000/800/A500-7x

Chapter 1 1

Page 6: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)

❏ A6892-62001 750 Mhz processor.

• Set of updated labels (P/N, S/N and GSP MAC address) A5570-84013

• One A6889-40001 pullout Information card

• A6889-84009 Nameplate, rp2470.

Chapter 12

Page 7: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6889-67101 System Board Upgrade Procedure

A6889-67101 System Board Upgrade ProcedureThe following subsections provide the steps required to remove and replace the System Board.

System Board Removal

The System Board is the most time consuming component to remove and replace because all internal components in the server connect to it. Allow enough space, ESD pads, and time to perform the removal task.

CAUTION Make sure that the system, including the operating system, applications, and data base has been backed up prior to removing the System Board.

Removing Attached Components

Be sure to have an ESD compliant work surface and several ESD bags for the System Board and CPUs. If an ESD bag is not available, use an ESD pad.

Before beginning System Board removal, login to the GSP and document the GSP settings. Then perform the following tasks:

NOTE Removal of a component also includes disconnecting any cables attached to the component.

1. Power down the server and disconnect all power cords.

2. Remove the cover.

3. If needed, remove the card in slot 1 of the PCI I/O cardcage, then remove the PCI I/O Cardcage. Removal is illustrated on the PCI I/O cardcage cover.

4. Remove Power Supply cover.

5. Remove the Power Supply.

6. Remove all Memory DIMMs.

NOTE Note the order of DIMM installation prior to removal to ensure that DIMMs are replaced in the correct order.

7. Remove all CPUs (up to two). If necessary, refer to the Processor Module Upgrade procedure later in this document. Label the CPUs with proper information and package for return.

8. Disconnect the internal disk(s) from the Disc Media Backplane module(s).

9. Remove Disc Media Backplane modules (up to two).

Removing the System Board

To remove the System Board, perform the following steps:

1. Unplug and remove any remaining cables and connectors from the System Board.

2. Remove the two T-10 screws that secure the System Board to the Chassis.

Chapter 1 3

Page 8: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6889-67101 System Board Upgrade Procedure

3. From the front of the server, slide the System Board forward so that the retainer posts are positioned into the keyholes.

4. The board is now free and may be lifted out of the chassis.

5. Label the System Board with proper information and package for return.

NOTE The System Board is large, use caution when lifting it out of the server chassis.

The following picture shows a System Board with all components installed.

Installing the new System Board

Ensure that all components and cables are properly reconnected to the system board once it is installed. Once the system board is installed and operation has been verified, follow the procedures to ensure that the system software ID is reset.

NOTE The System Board is large, use caution when lifting and placing it into the server chassis.

NOTE Do not touch the Astro or use it to lift the System Board.

To replace the System Board, proceed as follows:

Step 1. From the front of the server, carefully insert the System Board into the chassis. When all posts are in place, push the board back to slide the slots under the standoff post rims that seat the board.

Chapter 14

Page 9: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6889-67101 System Board Upgrade Procedure

Step 2. Set DIP switches based on the CPU speed, as follows:

NOTE The DIP switch is located near the rear of the System Board, next to the GSP. The figure below displays the dipswitch and it’s exact location.

Step 3. Replace the two T-10 screws that secure the System Board to the Chassis.

Legend: 1 = Closed, 0 = Open

“A” Board “B” Board

(A5570-6X001) (A5570-6X016)

440 MHz 440 MHz 550 MHz

1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6

1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 1 1 1

rp2400 to rp2470 Upgrade Board

(A6889-67101)

650 MHz 750 MHz

1 2 3 4 5 6 1 2 3 4 5 6

1 0 1 1 1 1 1 0 0 1 1 1

Chapter 1 5

Page 10: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6889-67101 System Board Upgrade Procedure

Step 4. Reconnect all cables and connectors and remove the cardboard strip from the battery on the System Board.

Replacing Attached Components

The procedure to replace the System Board also includes reinstallation of the following:

Step 1. Install the new Disc Media Backplane modules (up to two).

Step 2. Install the DC-DC Converter Master and Slave boards (one set for each CPU installed). The converter boards are keyed and clearly labeled to avoid confusion.

Step 3. Replace all Memory DIMMs.

NOTE Replace Memory DIMMs in the order removed.

Step 4. Install all CPUs (up to two). If necessary, refer to the CPU Replacement procedure later in this document.

Step 5. Install Terminator Assembly (for single CPU systems only).

Step 6. Replace Power Supply

Step 7. Replace Power Supply cover

Step 8. Replace the PCI I/O Cardcage with PCI cards installed.

Step 9. Replace I/O card in slot #1 (if used).

Step 10. Install the A6144-63001 M-cable.

NOTE Replacement of a component also includes reconnecting all cables and connectors attached to the component.

Step 11. Reconnect all power cords to the System Backplane.

Step 12. Replace the cover.

Step 13. Power up the server.

Step 14. Reconfigure GSP LAN interface using the information that was documented in the System Board Removal procedures.

Step 15. Remove and discard pullout information card.

Step 16. Install new pullout information card by inserting non-keyed end into the access slot in the pullout channel.

Step 17. Apply new labels to the chassis.

Chapter 16

Page 11: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6889-67101 System Board Upgrade Procedure

The following picture shows the location of the Part Number/Serial Number label and the pullout information card.

Chapter 1 7

Page 12: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)Resetting the Software ID

Resetting the Software ID Ensure that a console is connected and operating in order to reset the software ID.

Software ID must be reset each time the system board is replaced. The Software ID (SWID) is computed from the original product number and the system serial number. The SWID must be reset when a new system board is installed in the server. If the SWID is not reset or correct, the following chassis code will be displayed:

SYSTEM NAME: XXXXXXXXXX

DATE: 05/25/1999 TIME: 16:32:04

ALERT LEVEL: 6 = Boot possible, pending failure - action required

REASON FOR ALERT

SOURCE: 3 = PDH

SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: 0

PROBLEM DETAIL: 0 = no problem detail

0x48001860300027BO 20424144 53534E23 - type 9 = ASCII Message SSN# BAD

0x58001860300027BO 00006303 17102004 - type 11= Timestamp 05/25/1999 16:32:04

A/a: ack read of this entry - Q/q quit Virtual Front Panel Display

Anything else redisplay the log entry

NOTE If the chassis display shown is present, enter the BCH menu and execute the System Software Update command (SS_UPDATE). The SS_UPDATE command is launched from the Service Menu as shown:

NOTE Using SSCONFIG on a Laptop or Palmtop, enter the current Lockword to generate the Hex password.

Service Menu: Enter command> SS_UPDATE

Lockword:/zd1435ba4

Enter Password (Hex):.........

LEDs: RUN ATTENTION FAULT REMOTE POWER

FLASH FLASH OFF ON ON

Command Description

SERialNumb Change or update serial number

SYSMOdel Upgrade/downgrade system model

MPEMOdelString MPE XL model string in UNARCH SS

OS_ID OS_ID number in ARCH SS

SWCap SW Capabilities in UNARCH SS

DIsplay Display the ss_update menu

MAin Display the main menu

Chapter 18

Page 13: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)Resetting the Software ID

SS_update Menu: Enter Command>serialnumb

Original System Serial number is ??????????.

Enter the System Serial Number, <RETURN> FOR DEFAULT: USC41409SC

This action cannot be undone.

Confirm System Serial Number USM3924321 [Y/N/Q(uit)]?_y_

The system has been initialized with Serial Number USC41409SC

Original Product Number is: A6889A

NOTE The following Product Numbers apply:

A6889A = rp2400

A6890A = rp2470 (650 MHz)

A6890AD = rp2470 (750 MHz)

To change enter the Original Product Number otherwise press Return:A6889A

SS_update Menu: Enter command>__

NOTE Use the 'sysmodel' command to change model string to 9000/800/A500-6x for 650MHz or 9000/800/A500-7x for 750MHz

Perform a CTRL B reset and allow the boot process to continue. Ensure that the system passes self-tests and boots normally with no errors and is ready for use by the customer.

HElp [<command>] Display help for specified command

Command Description

Chapter 1 9

Page 14: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6891-62001/A6892-62001 Processor Module Upgrade Procedure

A6891-62001/A6892-62001 Processor Module Upgrade Procedure

CPU Removal

There are two CPU sockets in each rp2470 server. Removal procedures are described in the following paragraphs.

CAUTION Ensure that the system is shut down and power removed from the server before attempting removal or replacement of a component.

To remove a CPU from the server, perform the following steps:

Step 1. Carefully vacuum the area surrounding the CPU to be removed.

Step 2. Loosen the four captive T-15 mounting screws that hold the CPU in place.

NOTE Loosen the four CPU mounting screws a little at a time, in a cross pattern (1, 3, 2, 4) until they are all loose. The mounting screws will not back out of the CPU assembly.

Step 3. Grasp the top of the CPU assembly and carefully lift it out of the server.

Place the CPU on a clean surface. If the CPU is going to be out of the server for any length of time, place a dust cover in the CPU socket on the system board to protect against particle contamination.

Chapter 110

Page 15: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6891-62001/A6892-62001 Processor Module Upgrade Procedure

The following graphic shows the location of both CPUs in the server.

NOTE The rp2400 system supports one CPU; the rp2470 supports two CPUs.

Chapter 1 11

Page 16: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)CPU Replacement

CPU Replacement

Installing the CPU

Install CPUs according to the procedure listed below:

Step 1. Carefully align the CPU notches with the socket notches and set the CPU in place.

Step 2. Tighten the four captive T-15 mounting screws that hold the CPU in place.

NOTE Tighten the four CPU mounting screws a little at a time, in a cross pattern (1, 3, 2, 4), until they are all tight.

The following picture shows both CPUs installed in a server.

Chapter 112

Page 17: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6889-67102 Guardian Service Processor (GSP) Upgrade Procedure

A6889-67102 Guardian Service Processor (GSP) Upgrade Procedure

GSP Removal

The GSP card resides on the System Board at the rear left center, under the short PCI I/O card (slot 1), which must be removed for access.

Before removing the GSP from the server, perform the following steps:

CAUTION Ensure that the system is shut down and power removed from the server before attempting removal or replacement of a component.

To remove the GSP from the server, perform the following steps:

Step 1. Loosen the four mounting screws that hold the GSP card in place.

Step 2. Grasp the card by the left and right edges, rock it gently to free it from its socket on the System Board, and lift it out of the server.

The following picture shows the a GSP installed in a server.

Chapter 1 13

Page 18: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)A6889-67102 Guardian Service Processor (GSP) Upgrade Procedure

GSP Replacement

The GSP card resides on the System Board at the rear left center, under the short PCI I/O card (slot 1), which must be removed for access.

To replace the GSP, perform the following steps:

Step 1. Grasp the card by the left and right edges and press it gently into its socket on the System Board.

Step 2. Insert and tighten the four mounting screws that hold the GSP card in place.

Chapter 114

Page 19: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)Guardian Service Processor Firmware Update

Guardian Service Processor Firmware UpdateThis section details the procedures to update the Guardian Service Processor (GSP) firmware. Before starting the update procedures, there are some pre-update activities to check or perform.

• The update files exist on an FTP server accessible to the GSP LAN.

• The GSP LAN has been configured (using the LC command).

• The GSP internal port is configured (refer to Accessing GSP Internal Port for procedures).

An update file set consists of three files (APPLICATION.ROM, BOOTSTRAP.ROM, and upgrade.cnf).

To update the firmware on the GSP, perform the following steps:

1. Access the GSP by using the ctrl+b command from the local console keyboard, through the local port, or from an HP-UX server (through GSP internal port), use the cu command.

2. At the GSP prompt (GSP>) type he, to display the help menu, as shown:

GSP> heHE

Hardware Revision X Firmware Revision A.XX.XX July 16 1999, 17:19:31

3. Select the GSP command XU. This command activates the upgrade mode.

======== GSP Help ===================================(Administrator=======

AC: Alert display configuration MS: Modem Status

AR: Config. automatic system restart PC: Remote power control

CA: Configure serial port parameters PG: PaGing parameter setup

CL: Console Log-view console history PS: Power management module status

CO:COnsole-Return to console mode RS: reset System through RST signal

CSP: Conect to remote Service Proc. SDM: Set Display Mode (hex or text)

DC: Default Configuration SE: SEssion-log into the system

DI: DIsconect remote or LAN console SL: Show Logs (chassis code buffer)

EL: Enable/disable LAN/WEB access SO: Security options & access control

ER: Enable/Disable remote modem SS: System Status of proc. modules

EX: Exit GSP and disconnect TC: reset via Transfer of Control

HE: Display HElp for menu or command TE: TEll-send a msg to other users

IT: Inactivity Timeout settings VFP: Virtual Front Panel display

LC: LAN configuration WHO: Display connected GSP users

LS: LAN Status XD: Diagnostics and/or Reset of GSP

MR: Modem Reset XU: Upgrade the GSP Firmware

Chapter 1 15

Page 20: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)Guardian Service Processor Firmware Update

CAUTION All connections will be closed, the network will be stopped, the sessions will be aborted and the modem connection will be dropped when the XU command is executed.

GSP> xu

xu

This command activates the upgrade mode. All connections will be closed, the network will be stopped, the sessions will be aborted and the modem connection will be dropped.

Please confirm your intention to activate the upgrade mode (Y/[N]: y

Enter source system IP address: 192.001.11.92 (example only)

Enter file path: /directory/filename (example only)

Do you wish to use the default login: anonymous/[email protected] (Y/[N]): y

-> GSP firmware upgrade in progress-> GSP firmware upgrade complete - GSP will now reset

NOTE If returned to the GSP prompt (GSP>) instead of the reset message, the update was not successful. This may be caused by incorrect information, or the LAN was not configured properly. Check the LAN parameters (using the LS command) and try again.

4. Use ctrl+b to re-login to GSP (or the cu command from the internal port).

5. Re-enter the GSP he command to verify that the firmware revision number has changed to the updated version.

NOTE If updating from the GSP internal port, following the last message above, exit the cu command and re-issue the cu command in order to continue using the GSP from the internal port.

Once the GSP has reset, reconnect all sessions that were aborted.

Chapter 116

Page 21: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)Configuring the LAN Console Port

Configuring the LAN Console PortThe following example shows the steps required to configure the LAN Console Port. At the GSP> prompt, enter ls. The terminal will display:

LS

LAN configuration:

.MAC Address :0x00306e1ee08e

.IP Address :

.GSP Host Name :

.Subnet Mask :

.Gateway address :

.web console Port Number :2023

LAN status:

GSP Host Name:GSP>lcLCThis command allows you to modify the LAN configuration.Current configuration:.MAC Address :0x00306e1ee08e.IP Address :.GSP Host Name :.Subnet Mask :.Gateway address :.web console Port Number :2023

Do you want to modify the LAN configuration? (Y/[N]) yyCurrent IP address:Do you want to modify it? yyEnter new IP Address: 15.99.49.115.99.49.1New IP Address: 15/99.49.1Confirm (Y/[N]) yy

->IP Address will be updated

Current GSP Host Name:Do you want to modify it? yyEnter new GSP Host Name: harmony-charmony-cNew GSP Host Name: harmony-cConfirm (Y/[N]) yy

->GSP Host Name will be updated

Current Subnet Mask::Do you want to modify it? yyEnter new Subnet Mask: 255.255.248.0255.255.248.0New Subnet Mask: 255.255.248.0Confirm (Y/[N]) yy

->Subnet Mask will be updated

Current Gateway:Do you want to modify it? yyEnter new Gateway: 15.99.49.25415.99.49.254New Gateway: 15.99.49.254Confirm (Y/[N]) y

Chapter 1 17

Page 22: HP Server Rp2400 to Rp2470 System Upgrade Procedure Edition 1 February 2003

rp2400 to rp2470 System Upgrade Procedure (A9804A)Configuring the LAN Console Port

y->Gateway will be updated

Current Web Console Port Number: 2023Modifying Web Port number will cause all present webconnections to be dropped.Do you want to modify it? (Y/[N]) nn-> Settings have been updated.-> Reset the GSP for LAN configuratio to take effect.-> Use the R option of the XD commandto reset the GSPGSP Host Name: harmony-c

Chapter 118