Boot Sequence: PA-RISC 1] Poweron. 2] PDC Activates and checks for CPU and memory and other peripheral connected to it. 3] Checks if AUTOBOOT Flag is on. If yes , its try to locate the Primary boot path. 4] And loads Initial system loader , from Primary boot path. 5] ISL Loads the secondery loader called hp-ux. 6] hpux loads the kernel /stand/vmunix 7] kernel starts first process swapper , and then init 8] Shell /sbin/pre_init_rc executes . 9] init locates /etc/inittab 10] /etc/inittab starts the system the default run level , mentioned with "initdefault" parameter. 11] Then executes /sbin/bcheckrc and activates LVM , it does following : 1) activates LVM (if appplicable). # 2) runs eisa_config in automatic mode # (if applicable). # 3) checks the file systems before mounting. # (the scripts required for file system specific # checking reside in /sbin/fs/<fstype>/bcheckrc) # 4) and anything else that should be done before # mounting any file systems. ------------------ It checks for the file /sbin/lvmrc and , /etc/lvmrc activates the LVM , if AUTO_VG_ACTIVATE=1 mentioned. 12 ]Then it spawns getty process , cons:123456:respawn:/usr/sbin/getty console console And it gives login : prompt. HP-UX Tips and tricks Resetting GSP from Command line # stty +resetGSP </dev/GSPdiag1
Transcript
Page 1: HPUnix Tips and tricks

Boot Sequence: PA-RISC1] Poweron. 2] PDC Activates and checks for CPU and memory and other peripheral connected to it. 3] Checks if AUTOBOOT Flag is on. If yes , its try to locate the Primary boot path. 4] And loads Initial system loader , from Primary boot path. 5] ISL Loads the secondery loader called hp-ux. 6] hpux loads the kernel /stand/vmunix 7] kernel starts first process swapper , and then init 8] Shell /sbin/pre_init_rc executes . 9] init locates /etc/inittab 10] /etc/inittab starts the system the default run level , mentioned with "initdefault" parameter. 11] Then executes /sbin/bcheckrc and activates LVM ,

it does following :

1) activates LVM (if appplicable). # 2) runs eisa_config in automatic mode # (if applicable). # 3) checks the file systems before mounting. # (the scripts required for file system specific # checking reside in /sbin/fs/<fstype>/bcheckrc) # 4) and anything else that should be done before # mounting any file systems. ------------------

It checks for the file /sbin/lvmrc and , /etc/lvmrc activates the LVM , if AUTO_VG_ACTIVATE=1 mentioned.

12 ]Then it spawns getty process , cons:123456:respawn:/usr/sbin/getty console console And it gives login : prompt.

HP-UX Tips and tricks

Resetting GSP from Command line# stty +resetGSP </dev/GSPdiag1

Find out the boot path from command line# echo "boot_string/S" | adb /stand/vmunix /dev/mem

How to extend a file system in hp-ux# lvextend -L 1500 /dev/vgxx/lvolx (assuming the final size will be 1.5GB)# fsadm -F vxfs -b 1500m /xxx (xxx=mount point) If you have online JFS. or # umount /xxx # extendfs -F vxfs /dev/vgxx/rlvolx

Page 2: HPUnix Tips and tricks

How to create a patch depot# swcopy -s /soft/patch/PHSS_35546.depot PHSS35546 @ /soft/patch/depot

To Display mode parameter of a SCSI Device# /usr/sbin/scsictl -a -m ir=1 -m ir /dev/rdsk/c1t15d0

How to create a file systemFirst check the available disks and minor no for the VG you want to create# ll /dev/*/group ( Will look like this)crw-rw-r-- 1 root sys 64 0x010000 Sep 16 2006 /dev/vg-ignite/groupcrw-r----- 1 root sys 64 0x000000 Sep 16 2006 /dev/vg00/groupNote down the next available minor no. In this example we can use0x020000 (0x for hex then 02 is for VG and next 0000 is reserved for logical volumes)# mkdir /dev/vg-test# mknod /dev/vg-test/group c 64 0x02000# vgcreate /dev/vg-test /dev/dsk/c1t15d0 (assuming on this disk you want to create VG)then# lvcreate -L 20480 -n lv-TEST /dev/vg-TEST (assuming 20GB LV Size you want)# newfs -F vxfs -o largefiles /dev/vg-test/rlv-test# mount /dev/vg-test/lv-test /test

To check the contents of a Itanium based make_tape_recovery do the following.(You can use -xvf to restore any file too.)# mt -t /dev/rmt/0mn rew# mt -t /dev/rmt/0mn fsf 22# tar -tvf /dev/rmt/0mn

Find the list of files in a bundle.First find the Bundle name from the Depot# swlist -l bundle -s /patch/11.00/depotThen# swlist -l file -l bundle -s/patch/11.00/depot PB_11_00_march_2003

How to make a Software packageFirst swcopy to a depot then Ex. Assuming the the depot is /patch/11.00/depotCreate the bundle first# make_bundles -B i -n "PB_11_00_march_2003" -t "Patch Database March 2003" \-o /patch/11.00/depot/PB_March_2003_11.00.psf -r 1.0 /patch/11.00/depotthen run # swpackage -s /patch/11.00/PB_March-2003_11.00.psf -xlayout_version=1.0 -xreinstall_files=true \-d /patch/11.00/depot

To unregister a CD-ROM depot mounted at /mnt/cd, you would type:# swreg -l depot -u /mnt/cd

To register the same depot (mounted at /mnt/cd on the local host) as a depot to be available on the network, type:swreg -l depot /mnt/cd

The following example enables direct access from one or two other systems to the HWEnable11i depot on the Support Plus CD, assuming the Support Plus CD is mounted at /cdrom:

# swreg -l depot /cdrom/HWEnable11i0.

SCSI Tuning in HP-UX# scsictl -a /dev/rdsk/c4t6d0 -- too see the parameters# scsictl -m queue_depth=32 /dev/rdsk/c4t6d0 - to change from default 8k to 32k# scsictl -c get_lun_parms /dev/rdsk/cxtxdx does the same as scsictl -a

To set the immediate report on and display all mode parameters for SCSI Device# scsictl -a -m ir=1 -m ir /dev/rdsk/c4t6d0

To see the scsi_max-q_depth settings run # kctune scsi_max_qdepth

Page 3: HPUnix Tips and tricks

To change it from default 8 to desired 32k permanently # kctune scsi_max_qdepth=32 and type y when it asks for confirmation

How to determine the SCSI queue depth for a device in HP-UX # scsictl -m queue_depth /dev/rdsk/cxtxdx

How to change the SCSI queue depth for a device in HP-UX# scsictl -m queue_depth=X /dev/rdsk/cxtxdx

How to Mirror VG00 using LVM with HPUX-11.23IAHP Document ID : KBRC00014526NOTE: There are differences in procedure between 11.22 and 11.23.Please refer to KBRC00011156 for B.11.22.1. From HPUX, use vgdisplay to identify the disk that is in vg00. Use ioscan to find the spare disk.# vgdisplay -v --> vg00 is on /dev/dsk/c2t1d0s2 in this example# ioscan -efunC disk --> Let's assume c3t2d0 for this example2. Create the system, OS, and service partitions.# vi /tmp/partitionfile3EFI 500MBHPUX 100%HPSP 400MB# idisk -wf /tmp/partitionfile /dev/rdsk/c3t2d0idisk version: 1.31********************** WARNING ***********************If you continue you may destroy all data on this disk.Do you wish to continue(yes/no)? yes <-- Answer "yes" and not "y"3. Create device files needed for the new partitions.# insf -eC disk4. Verify the partition table.# idisk /dev/rdsk/c3t2d05. Verify that the device files were created properly.# ioscan -efnC disk --> c3t2d0 is 0/1/1/1.2.06. Populate the /efi/hpux/ directory in the new EFI system partition.# mkboot -e -l /dev/rdsk/c3t2d07. Change the auto file for the mirror to boot without quorum.NOTE: Using "s1"# echo "boot vmunix -lq" > /tmp/AUTO.lq# efi_cp -d /dev/rdsk/c3t2d0s1 /tmp/AUTO.lq /EFI/HPUX/AUTONOTE: We assume that if we boot from the primary, the mirror is fullyfunctional and therefore we don't need to override quorum. Your sitemight require that both disks override quorum.9. Verify the contents of the auto file on the primary and the mirror.NOTE: Using "s1"# efi_cp -d /dev/rdsk/c2t1d0s1 -u /EFI/HPUX/AUTO /tmp/AUTO.pri# efi_cp -d /dev/rdsk/c3t2d0s1 -u /EFI/HPUX/AUTO /tmp/AUTO.alt# cat /tmp/AUTO.pri# cat /tmp/AUTO.alt10. Add the new partition to vg00.NOTE: Using "s2"# pvcreate -fB /dev/rdsk/c3t2d0s2# vgextend vg00 /dev/dsk/c3t2d0s211. Mirror all logical volumes in vg00.NOTE: Using "s2"# lvextend -m 1 /dev/vg00/lvol1 /dev/dsk/c3t2d0s2# lvextend -m 1 /dev/vg00/lvol2 /dev/dsk/c3t2d0s2# lvextend -m 1 /dev/vg00/lvol3 /dev/dsk/c3t2d0s2...# lvextend -m 1 /dev/vg00/lvol8 /dev/dsk/c3t2d0s212. Add the new disk to /stand/bootconf.NOTE: Using "s2"# vi /stand/bootconfl /dev/dsk/c2t1d0s2

Page 4: HPUnix Tips and tricks

l /dev/dsk/c3t2d0s213. Verify that the new disk was added to vg00, and the lv's are insync.# vgdisplay -v vg0014. Verify that the BDRA was updated properly. Take note of the HWpaths forstep 15.# lvlnboot -v15. Add EFI primary and high availability boot path menu entries.# setboot -p 0/1/1/0.1.0 <-- Set primary disk# setboot -h 0/1/1/1.2.0 <-- Set mirror disk# setboot -b on <-- Set autoboot on16. Verify that the primary and mirror boot paths are configuredproperly.# setboot17. Test the new mirror by booting off of it.# shutdown -r -y 018. Select "HP-UX HA Alternate Boot" to test the mirror.EFI Boot Manager ver 1.10 [14.61] Firmware ver 2.21 [4334]Please select a boot optionHP-UX Primary Boot: 0/1/1/0.1.0HP-UX HA Alternate Boot: 0/1/1/1.2.0EFI Shell [Built-in]20. Verify which disk/kernel you booted from.# grep "Boot device" /var/adm/syslog/syslog.logvmunix: Boot device's HP-UX HW path is: 0.1.1.1.2.021. Remove temporary files.# rm /tmp/partitionfile /tmp/AUTO*Done.Date 0/31/04

INQ displaying devices as ACCESS DENIED (from EMC)Use rmsf command to remove the entries (Cause: Migrated from old Symmetrix to a new Symmetrix)

Host cannot see more than 8 luns per port ( From EMC)For HP-UX hosts with HDS 9960 or HP XP512 arrays: Set the host mode to 03, not 08, as the HDS documentation specifies. Setting the host mode to 03 enables the host to see more than 8 LUNs per port.

How to test if PowerPath is load balancing and configured properly to failover (emc87060)The following procedure can be used to make sure that PowerPath is configured properly for load balancing and failover. This example was done on an HP-UX machine, but it will work (with modifications for the device names) on any Unix host:

Pick a Symmetrix device and note all of the native paths configured for that device:

# powermt display dev=c24t0d1Symmetrix ID=000187400662Logical device ID=0011state=alive; policy=SymmOpt; priority=0; queued-IOs=0================================================---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---### HW Path I/O Paths Interf. Mode State Q-IOs Errors================================================24 0/10/0/0.97.32.19.0.0.1 c24t0d1 FA 13aA active alive 0 035 0/12/0/0.97.32.19.0.0.1 c35t0d1 FA 13aA active alive 0 037 0/10/0/0.97.29.19.0.0.1 c37t0d1 FA 4bA active alive 0 038 0/12/0/0.97.29.19.0.0.1 c38t0d1 FA 4bA active alive 0 0

Set the policy to Round Robin for that device:

# powermt set policy=rr dev=c24t0d1# powermt display dev=c24t0d1 | grep policystate=alive; policy=RoundRobin; priority=0; queued-IOs=0

Page 5: HPUnix Tips and tricks

Start I/O to a single device in the group (in this case, use the block device as the input file and /dev/null as the output file to read from the device):

# dd if=/dev/dsk/c24t0d1 of=/dev/null

Show I/O on all of the paths to that device:

# sar -d 10 HP-UX curly B.11.11 U 9000/800 05/18/0415:54:21 device %busy avque r+w/s blks/s avwait avserv15:54:31 c1t2d0 0.50 0.50 3 44 4.30 1.54c24t0d1 6.79 0.50 336 2688 5.04 0.24c35t0d1 8.08 0.50 336 2688 5.04 0.21c37t0d1 6.79 0.50 336 2688 5.03 0.25c38t0d1 7.68 0.50 336 2689 5.05 0.21

There is I/O down all four paths to Symmetrix device 0011.

Note: In the above example, there is only I/O down the four paths to device 0011 and to the internal disk (c1t2d0). If there is I/O to many devices on the system (almost certain in a production environment), egrep can be used to display only the paths to the Symm device in question:

# sar -d 10 | egrep "c24t0d1|c35t0d1|c37t0d1|c38t0d1"16:00:56 c24t0d1 8.90 0.50 366 2929 5.06 0.20c35t0d1 6.70 0.50 366 2929 5.02 0.20c37t0d1 6.70 0.50 366 2929 4.99 0.21

How to interpret HP-UX device numbers from SCSI read and write errors in the syslog - emc88252When SCSI read and write errors are logged in the syslog, the device number is written in hex. For example:Jun 2 21:13:38 pdb01 vmunix: SCSI: Read error -- dev: b 31 0x2b8400, errno: 126, resid: 8192,Jun 2 21:13:39 pdb01 above message repeats 13 timesJun 2 21:13:39 pdb01 vmunix: - dev: b 31 0x2b8400, errno: 126, resid: 8192,Jun 2 21:13:39 pdb01 vmunix: blkno: 2895352, sectno: 5790704, offset: -1330126848, bcount: 8192.Jun 2 21:13:52 pdb01 vmunix: SCSI: Write error -- dev: b 31 0x038400, errno: 126, resid: 8192,Jun 2 21:13:52 pdb01 vmunix: blkno: 5454416, sectno: 10908832, offset: 1290354688, bcount: 8192.The numbers can be broken down as follows:vmunix: SCSI: Write error -- dev: b 31 0x2b84002b = Controller 438 = Target 84 = LUN 4This translates to c43t8d4vmunix: SCSI: Read error -- dev: b 31 0x03840003= Controller 38 = Target 84 = LUN 4This translates to c3t8d4

There is another very easy way to find it : (my note). SCSI write error is most probably either disk or tape. In this case major no is 31 which is always for disk in hp-ux. So run ll /dev/dsk and grep for the entry 0x038400 and you will know right away which is the device.

There are 2 paths to the same Symmetrix device (091) that is logging the read and write errors:/dev/rdsk/c3t8d4 :EMC :SYMMETRIX :5568 :32091000 :8838720/dev/rdsk/c43t8d4 :EMC :SYMMETRIX :5568 :32091000 :8838720In most cases when this type of error is seen against Symm devices, the issue is logical corruption and running fsck on the affected logical volumes or devices will solve the problem.

VXFS Related FAQS

To increase or decrease space in file system. First extend the LVM

Page 6: HPUnix Tips and tricks

# lvextend -L 72 /dev/vg01/lvol1# fsadm -b new_size mount_point (here 72*1024,assuming 1K block size )

How to report on directory fragmentation vxvm# fsadm –D mount_point

How to reorganize directories vxvm to reduce fragmentation and reclaim wasted space# fsadm –d mount_point

How to report on extent fragmentation within a file system vxvm# fsadm –E mount_point

Reorganize (defragment) a file system's extents to reduce fragmentation and reclaim wasted space.# fsadm –e mount_point

Create a snapshot file system. First create separate LVM for that purpose# lvcreate –L 20 /dev/vg02/snap_back# mkdir /backhome# mount –o snapof=primary_special special mount_point# mount –o snapof=/dev/vg02/lvdata /dev/vg02/snap_back /backhome

Change extent attributes. To maximize performance.# setext –e extent_size –r reservation -f flags file

How to export and import a Volume GroupFrom the source Server do the these stepsunmount the filesystem(s) of the VG you want to exportumount /test (Ex. /test is the mount point)vgchange -a n vg-testvgexport -p -m vg-test.map vgtest (To preview and create the mapfile. To export omit -p)on the New Serverioscan –fnC disk (To find new disk entries)insf –d sdisk (To install the disk device files)ll /dev/*/group (To see what minor numbers have already been used)mkdir /dev/vg-test (To create the directory)mknod /dev/vgx/group c 64 0x00000 (To create the device file)vgimport -m /dev/dsk/cxtxdx /dev/dsk/cxtxdx (To import the volume group)vgchange -a y (to activate the volume group)mkdir /testand mount /dev/vg-test/lvxx /test

How to test network bandthwitdh / Test ftp data transfer rate without actual transfererring ftp targethostusername/passwd...binhashput "|dd if=/dev/zero bs=32k count=1000" /dev/null

How to convert numbers to and from binary format.To make the conversion of value 195 to binary format, enter:bcobase=21000 1111101000To convert the binary number 1111101000 to a decimal format, enter:bcibase=211111010001000

How to mount a ISO image# nohup pfs_mountd &

Page 7: HPUnix Tips and tricks

# nohup pfsd & # pfs_mount -o xlat=UNIX pathToIso mountPointor# usr/sbin/pfs_mount -t iso9660 -x unix /images/cd.iso /mnt

Problem : Unable to recover rx2620 server to rx7620 possible (tested) solution : - Boot from the recovery tape. Note down each file systems size and delete them and re-create them from the Ignite Menu. I successfully recovered on of my clients's server using this method. I don't know anyone else ever tested it or not.

How to use linkloop commandSuppose you want to troubleshoot network problem and you have the mac address of the remote server running hp-ux. From your current server u want to check the connectivity using lan0. From ioscan -funClan you got the instance no. which is 0 and MAC of the remote ethernet card is 0x00306EF3FDBD. the syntax will be: # linkloop -vi 0 0x00306EF3FDBD

If swinstall, swlist or SAM takes very long time to come back Check /etc/hosts file and match the hostname with proper IP address. Then check /etc/resolv.conf file and check the correct entries and see if you can ping the dns server or not. For instant solution you may rename it and then run swagentd -r command. Once you are done u can move that file back and rerun swagentd -r again.

How to to check any Tape Library and Optical Jukebox# ioscan –funCautoch ( And note down the device name with path)Ex. /dev/rac/cxtxdx# mc –p /dev/rac/cxtxdx –r IDSM ( Will show all the slot and Drive information)# mc –p /dev/rac/cxtxdx –e IDSM ( Will show less detailed information)

How to find the tapes in the slots#mc –p /dev/rac/cxtxdx –r IDSM |grep –i full

How to move Tape from a Storage slot 5 to drive 1# mc –p /dev/rac/cxtxdx –s S5 –d D1 ( -s = Source, -d = destination) ( S= Storage Slot, D=Drives, E=Export/Import Slot, M=Media changer i.e robot)

How to display all informations of all the nPars# parstatus

How to display properties of nPar0 only# parstatus -V -p0

Example of a parcreate command to create a partition name shreya with Cell2 and cell3(Remember at least one Cell must have core io attached to it i.e should have IO Drawers)# parcreate -P shreya -c 2:base:y:ri -c 3:base:y:ri

Here is the output of parstatus command without any switch(I am not explaining as man page has all the informations, but this screenshot will help people who are new to nPar world)root@SDPROD0> parstatusWarning: No action specified. Default behaviour is display all.[Complex]Complex Name : GODComplex CapacityCompute Cabinet (8 cell capable) : 1Active GSP Location : cabinet 0Model : 9000/800/SD32000Serial Number : USE12345678Current Product Number : A5201AOriginal Product Number : A5201AComplex Profile Revision : 1.0The total number of Partitions Present : 2

[Cabinet]Cabinet I/O Bulk Power Backplane

Page 8: HPUnix Tips and tricks

Blowers Fans Supplies Power BoardsOK/ OK/ OK/ OK/Cab Failed/ Failed/ Failed/ Failed/Num Cabinet Type N Status N Status N Status N Status GSP=== ============ ========= ========= ========== ============ ======0 SD32000 4/ 0/ N+ 5/ 0/ ? 6/ 0/ N+ 3/ 0/ N+ active

Notes: N+ = There are one or more spare items (fans/power supplies).N = The number of items meets but does not exceed the need.N- = There are insufficient items to meet the need.? = The adequacy of the cooling system/power supplies is unknown.

[Cell]CPU Memory UseOK/ (GB) Core OnHardware Actual Deconf/ OK/ Cell Next ParLocation Usage Max Deconf Connected To Capable Boot Num========== ============ ======= ========= =================== ======= ==== ===cab0,cell0 active core 4/0/4 16.0/ 0.0 cab0,bay1,chassis3 yes yes 1cab0,cell1 active base 4/0/4 12.0/ 0.0 cab0,bay0,chassis3 yes yes 1cab0,cell2 inactive 4/0/4 8.0/ 0.0 - no - -cab0,cell3 inactive 4/0/4 12.0/ 0.0 - no - -cab0,cell4 active core 4/0/4 12.0/ 0.0 cab0,bay0,chassis1 yes yes 0cab0,cell5 active base 4/0/4 12.0/ 0.0 - no yes 0cab0,cell6 active base 4/0/4 12.0/ 0.0 cab0,bay1,chassis1 yes yes 0cab0,cell7 inactive 4/0/4 12.0/ 0.0 - no - -

[Chassis]Core Connected ParHardware Location Usage IO To Num=================== ============ ==== ========== ===cab0,bay0,chassis0 absent - - -cab0,bay0,chassis1 active yes cab0,cell4 0cab0,bay0,chassis2 absent - - -cab0,bay0,chassis3 active yes cab0,cell1 1cab0,bay1,chassis0 absent - - -cab0,bay1,chassis1 active yes cab0,cell6 0cab0,bay1,chassis2 absent - - -cab0,bay1,chassis3 inactive yes cab0,cell0 1

[Partition]Par # of # of I/ONum Status Cells Chassis Core cell Partition Name (first 30 chars)=== ============ ===== ======== ========== ===============================0 active 3 2 cab0,cell4 sdprod01 active 2 1 cab0,cell0 sdoraprod1

Problem : Unable to recover RP4440 server to another RP4440 Server. OS loaded from make_tape_recovery but after OS Installation completed it fails

Possible Solution : Check the SCSI Card you are using on both the Servers. Probably old RP4440 using Ultra 160 LVD card and the new RP4440 is using Ultra320 Card. One possible and tested solution is add one Ultra 160 LVD SCSI card in the new Server and connect the SCSI Internal Disks to it. Second tested Solution is same but you can use External DASD like DS2300 or DS2320. Third solution is install the Driver to the OS of old Server for the Ultra320 LVD SCSI Card or the Card used in the New Server and then run make_tape_recovery on old server.

Problem : linkloop works fine still unable to ping the router or any other server in the same network.

possible solution : This worked for three servers with same issue but don't have any explanation. run ifconfig lan0 down and ifconfig lan0 unplumb and then run ifconfig lan0 plumb and ifconfig lan0

Page 9: HPUnix Tips and tricks

xxx.xxx.xxx.xx netmask xxx.xxx.xxx.xx. link workes means that the Servers can see each other i.e. connected to link level. (xxx=replace with ip address and subnet mask)

HP Service Guard Cluster This article describes the installation steps for a MC/Serviceguard Cluster Installation on two

HP-UX Servers.

Environment:

Server 1:

Hardware: HP Integrity rx4640

OS: HP-UX B.11.31

Servername: boston.vogtnet.com

Stationary IP: 172.16.18.30 (lan0)

Heartbeat IP: 10.10.1.30 (lan1)

Standby: (lan2)

Lock Disk: VG: /dev/vglock

PV: /dev/disk/disk12

Server 2:

Hardware: HP Integrity rx4640

OS: HP-UX B.11.31

Servername: denver.vogtnet.com

Stationary IP: 172.16.18.31 (lan0)

Heartbeat IP: 10.10.1.31 (lan1)

Standby: (lan2)

Page 10: HPUnix Tips and tricks

Lock Disk: VG: /dev/vglock

PV: /dev/disk/disk12

Storage:

HP Enterprise Virtual Array EVA8000 SAN

Cluster Installation Steps

1. Configure   /etc/hosts

-> on boston.vogtnet.com:

# vi /etc/hosts

—————————————-

# boston

172.16.18.30 boston.vogtnet.com boston

10.10.1.30 boston.vogtnet.com boston

127.0.0.1 localhost loopback

# denver

172.16.18.31 denver.vogtnet.com denver

10.10.1.31 denver.vogtnet.com denver

—————————————-

-> on denver.vogtnet.com

# vi /etc/hosts

—————————————-

Page 11: HPUnix Tips and tricks

# denver

172.16.18.31 denver.vogtnet.com denver

10.10.1.31 denver.vogtnet.com denver

127.0.0.1 localhost loopback

# boston

172.16.18.30 boston.vogtnet.com boston

10.10.1.30 boston.vogtnet.com boston

—————————————-

2. Set   $SGCONF   (on both nodes)

# vi ~/.profile

—————————————-

SGCONF=/etc/cmcluster

export SGCONF

—————————————-

# echo $SGCONF

/etc/cmcluster

3. Configure ~/.rhosts (for rcp, don’t use in secure envs)

-> on boston.vogtnet.com

# cat ~/.rhosts

denver root

-> on denver.vogtnet.com

# cat ~/.rhosts

boston root

Page 12: HPUnix Tips and tricks

4. Create the $SGCONF/cmclnodelist

(every node in the cluster must be listed in this file)

# vi $SGCONF/cmclnodelist

—————————————-

boston root

denver root

—————————————-

#rcp cmclnodelist denver:/etc/cmcluster/

5. Configure Heartbeat IP (lan1)

-> on boston.vogtnet.com

# vi /etc/rc.config.d/netconf

—————————————-

INTERFACE_NAME[1]=”lan1″

IP_ADDRESS[1]=”10.10.1.30″

SUBNET_MASK[1]=”255.255.255.0″

BROADCAST_ADDRESS[1]=”"

INTERFACE_STATE[1]=”"

DHCP_ENABLE[1]=0

INTERFACE_MODULES[1]=”"

—————————————-

-> on denver.vogtnet.com

# vi /etc/rc.config.d/netconf

—————————————-

Page 13: HPUnix Tips and tricks

INTERFACE_NAME[1]=”lan1″

IP_ADDRESS[1]=”10.10.1.31″

SUBNET_MASK[1]=”255.255.255.0″

BROADCAST_ADDRESS[1]=”"

INTERFACE_STATE[1]=”"

DHCP_ENABLE[1]=0

INTERFACE_MODULES[1]=”"

—————————————-

Restart Network:

# /sbin/init.d/net stop

# /sbin/init.d/net stop

# ifconfig lan1

lan1: flags=1843<UP,BROADCAST,RUNNING,MULTICAST,CKO>

inet 10.10.1.30 netmask ffffff00 broadcast 10.10.1.255

6. Disable the Auto Activation of LVM Volume Groups (on bot

nodes)

# vi /etc/lvmrc

—————————————-

AUTO_VG_ACTIVATE=0

—————————————-

7. Lock Disk

( The lock disk is not dedicated for use as the cluster lock; the disk can be

employed as part of a normal volume group with user data on it. The

Page 14: HPUnix Tips and tricks

cluster lock volume group and physical volume names are identified in

the cluster configuration file. )

However, in this cluster we use a dedicated Lock Volume Group so we are sure this VG will

never be deleted.

As soon as this VG is registered as lock disk in the cluster configuration, it will be

automatically marked as cluster aware.

Create a LUN on the EVA and present it to boston and denver.

boston.vogtnet.com:

# ioscan -N -fnC disk

disk 12 64000/0xfa00/0×7 esdisk CLAIMED DEVICE HP HSV210

/dev/disk/disk12 /dev/rdisk/disk12

# mkdir /dev/vglock

# mknod /dev/vglock/group c 64 0x010000

# ll /dev/vglock

crw-r–r– 1 root sys 64 0×010000 Jul 31 14:42 group

# pvcreate -f /dev/rdisk/disk12

Physical volume “/dev/rdisk/disk12″ has been successfully created.

// Create the VG with the HP-UX 11.31 agile Multipathing instead of LVM Alternate Paths.

# vgcreate /dev/vglock /dev/disk/disk12

Volume group “/dev/vglock” has been successfully created.

Volume Group configuration for /dev/vglock has been saved in /etc/lvmconf/vglock.conf

# strings /etc/lvmtab

/dev/vglock

/dev/disk/disk12

# vgexport -v -p -s -m vglock.map /dev/vglock

# rcp vglock.map denver:/

Page 15: HPUnix Tips and tricks

denver.vogtnet.com:

# mkdir /dev/vglock

# mknod /dev/vglock/group c 64 0x010000

# vgimport -v -s -m vglock.map vglock

–> Agile Multipathing of HP-UX 11.31 is not used by default after import (HP-UX 11.31 Bug ?!).

The volume group uses alternate LVM Paths.

Solution:

# vgchange -a y vglock

// Remove Alternate Paths

# vgreduce vglock /dev/dsk/c16t0d1 /dev/dsk/c14t0d1 /dev/dsk/c18t0d1

/dev/dsk/c12t0d1 /dev/dsk/c8t0d1 /dev/dsk/c10t0d1 /dev/dsk/c6t0d1

// Add agile Path

# vgextend /dev/vglock /dev/disk/disk12

// Remove Primary Path

# vgreduce vglock /dev/dsk/c4t0d1

Device file path “/dev/dsk/c4t0d1″ is an primary link.

Removing primary link and switching to an alternate link.

Volume group “vglock” has been successfully reduced.

Volume Group configuration for /dev/vglock has been saved in /etc/lvmconf/vglock.conf

# strings /etc/lvmtab

/dev/vglock

/dev/disk/disk12

# vgchange -a n vglock

// Backup VG

# vgchange -a r vglock

# vgcfgbackup /dev/vglock

Page 16: HPUnix Tips and tricks

Volume Group configuration for /dev/vglock has been saved in /etc/lvmconf/vglock.conf

# vgchange -a n vglock

8. Create Cluster Config (on boston.vogtnet.com)

# cmquerycl -v -C /etc/cmcluster/cmclconfig.ascii -n boston -n denver

# cd $SGCONF

# cat cmclconfig.ascii | grep -v "^#"

——————————————————————-

CLUSTER_NAME cluster1

FIRST_CLUSTER_LOCK_VG /dev/vglock

NODE_NAME denver

NETWORK_INTERFACE lan0

HEARTBEAT_IP 172.16.18.31

NETWORK_INTERFACE lan2

NETWORK_INTERFACE lan1

STATIONARY_IP 10.10.1.31

FIRST_CLUSTER_LOCK_PV /dev/dsk/c16t0d1

NODE_NAME boston

NETWORK_INTERFACE lan0

HEARTBEAT_IP 172.16.18.30

NETWORK_INTERFACE lan2

NETWORK_INTERFACE lan1

STATIONARY_IP 10.10.1.30

FIRST_CLUSTER_LOCK_PV /dev/disk/disk12

HEARTBEAT_INTERVAL 1000000

Page 17: HPUnix Tips and tricks

NODE_TIMEOUT 2000000

AUTO_START_TIMEOUT 600000000

NETWORK_POLLING_INTERVAL 2000000

NETWORK_FAILURE_DETECTION INOUT

MAX_CONFIGURED_PACKAGES 150

VOLUME_GROUP /dev/vglock

———————————————————————————–

-> Change this file to:

———————————————————————————–

CLUSTER_NAME MCSG_SAP_Cluster

FIRST_CLUSTER_LOCK_VG /dev/vglock

NODE_NAME denver

NETWORK_INTERFACE lan0

STATIONARY_IP 172.16.18.31

NETWORK_INTERFACE lan2

NETWORK_INTERFACE lan1

HEARTBEAT_IP 10.10.1.31

FIRST_CLUSTER_LOCK_PV /dev/disk/disk12

NODE_NAME boston

NETWORK_INTERFACE lan0

STATIONARY_IP 172.16.18.30

NETWORK_INTERFACE lan2

NETWORK_INTERFACE lan1

HEARTBEAT_IP 10.10.1.30

FIRST_CLUSTER_LOCK_PV /dev/disk/disk12

Page 18: HPUnix Tips and tricks

HEARTBEAT_INTERVAL 1000000

NODE_TIMEOUT 5000000

AUTO_START_TIMEOUT 600000000

NETWORK_POLLING_INTERVAL 2000000

NETWORK_FAILURE_DETECTION INOUT

MAX_CONFIGURED_PACKAGES 15

VOLUME_GROUP /dev/vglock

———————————————————————————–

# cmcheckconf -v -C cmclconfig.ascii

Checking cluster file: cmclconfig.ascii

Checking nodes … Done

Checking existing configuration … Done

Gathering storage information

Found 2 devices on node denver

Found 2 devices on node boston

Analysis of 4 devices should take approximately 1 seconds

0%—-10%—-20%—-30%—-40%—-50%—-60%—-70%—-80%—-90%—-100%

Found 2 volume groups on node denver

Found 2 volume groups on node boston

Analysis of 4 volume groups should take approximately 1 seconds

0%—-10%—-20%—-30%—-40%—-50%—-60%—-70%—-80%—-90%—-100%

Gathering network information

Beginning network probing (this may take a while)

Completed network probing

Checking for inconsistencies

Page 19: HPUnix Tips and tricks

Adding node denver to cluster MCSG_SAP_Cluster

Adding node boston to cluster MCSG_SAP_Cluster

cmcheckconf: Verification completed with no errors found.

Use the cmapplyconf command to apply the configuration.

# cmapplyconf -v -C cmclconfig.ascii

Checking cluster file: cmclconfig.ascii

Checking nodes … Done

Checking existing configuration … Done

Gathering storage information

Found 2 devices on node denver

Found 2 devices on node boston

Analysis of 4 devices should take approximately 1 seconds

0%—-10%—-20%—-30%—-40%—-50%—-60%—-70%—-80%—-90%—-100%

Found 2 volume groups on node denver

Found 2 volume groups on node boston

Analysis of 4 volume groups should take approximately 1 seconds

0%—-10%—-20%—-30%—-40%—-50%—-60%—-70%—-80%—-90%—-100%

Gathering network information

Beginning network probing (this may take a while)

Completed network probing

Checking for inconsistencies

Adding node denver to cluster MCSG_SAP_Cluster

Adding node boston to cluster MCSG_SAP_Cluster

Marking/unmarking volume groups for use in the cluster

Completed the cluster creation

Page 20: HPUnix Tips and tricks

// Deactivate the VG (vglock will be activated from cluster daemon)

# vgchange -a n /dev/vglock

9. Start the Cluster (on boston.vogtnet.com)

# cmruncl -v

cmruncl: Validating network configuration…

cmruncl: Network validation complete

Waiting for cluster to form ….. done

Cluster successfully formed.

Check the syslog files on all nodes in the cluster to verify that no warnings occurred during

startup.

# cmviecl -v

MCSG_SAP_Cluster up

NODE STATUS STATE

denver up running

Cluster_Lock_LVM:

VOLUME_GROUP PHYSICAL_VOLUME STATUS

/dev/vglock /dev/disk/disk12 up

Network_Parameters:

INTERFACE STATUS PATH NAME

PRIMARY up 0/2/1/0 lan0

PRIMARY up 0/2/1/1 lan1

STANDBY up 0/3/2/0 lan2

NODE STATUS STATE

boston up running

Page 21: HPUnix Tips and tricks

Cluster_Lock_LVM:

VOLUME_GROUP PHYSICAL_VOLUME STATUS

/dev/vglock /dev/disk/disk12 up

Network_Parameters:

INTERFACE STATUS PATH NAME

PRIMARY up 0/2/1/0 lan0

PRIMARY up 0/2/1/1 lan1

STANDBY up 0/3/2/0 lan2

10. Cluster Startup Shutdown

// Automatic Startup:

/etc/rc.config.d/cmcluster

AUTOSTART_CMCLD=1

// Manuel Startup

# cmruncl -v

// Overview

# cmviewcl -v

// Stop Cluster

# cmhaltcl -v