4
S TEAM C ONDENSER D ESIGNS
Transcript
Page 1: Document

Steam CondenSer deSignS

Page 2: Document

Yuba produces a series of highly efficient condensers, which are proven in service for industrial, cogeneration, and waste-to-energy applications.

Effective steam condenser design, of necessity, must take many performance variables into consideration. Not the least of these variables is:

•Theconfigurationoftheexhaustflowpatternenteringthecondenser

•Themoisturecontentoftheincomingsteam

•Thedesignofthetransitionpiecetoachievethemostuniform distribution of incoming steam over the tube bundle

•Shelldesignparametersthatprovidemaximumsupportto the tube bundle without impacting pressure drop

•De-aerationandre-heatrequirementsforthesteamcondensate

•Tubesheetdesignconsiderationsthatwillenhancethesteam flowoverandthroughthetubebundletoachievemaximum performance efficiencies

•Plusmanymoredesignvariablesthatimpactcondenserperformance.

Steam CondenSer that Work right For You.

Page 3: Document

Yuba consistently addresses a greater number of design considerations than most of its competitors. Based on current operations for Yuba condenserdesigns,andthedecadesofexperienceinYuba’sengineer-ingstaff,fewerunanticipateddesignanomaliesexist. Yuba engineers know what to anticipate.

Yuba steam surface condensers provide significant performance advantages. Including typically longer service lives. Yuba’sdesign methods, proven by fluid tests, facilitate the production of leak-tight weldedorrollerexpandedjointswiththinwalledtubing,whether 25 BWG titanium or 22 BWG stainless steel.

Call Yuba Heat Transferforyoursteamsurfacecondenserneeds,whether they are for new units, or for repair or retrofit. Yuba has the answersforyoursteamsurfacecondenserquestions.

Shell

Steam Dump

Turbine Exhaust Connection

Stainless Steel Expansion Joint

Quick Opening Manway

Exhaust Neck

Tubes

Bolted Waterbox

Circulating Water Inlet Nozzle

Quick Opening Manway

Tube Support Plates

Hotwell

Tubesheet

Non-Condensable Offtake Connection

Condensate Outlet Nozzle

Circulating Water Outlet Nozzle

SupportBolted Type Waterbox (Welded Configuration Available)

Central Non-Condensable Duct

Page 4: Document

2121 NORTH 161 EAST AVENUETULSA, OKLAHOMA 74116UNITED STATES918 234 [email protected]