Date post: | 27-Jan-2016 |
Category: |
Documents |
Upload: | miguel-andres-vanegas |
View: | 93 times |
Download: | 11 times |
HetNet Topology to Catch Traffic Efficiently
Macro Macro
Pico MicroMacro
Macro
Micro
IBS IBS
IBSMicro Micro
IBSIBS
Pico
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 2
1 - 5x 10 - 50x 100 - 500x
MicroMicro
Pico
IBS
Macro Macro Macro
WiFi
Micro is a key component of HetNet
UMTS Micro Specification
Item Specification
Frequency band Support 2.1G, 1900M (FDD)
Carrier 2 carriers, support 2T2R MIMO,
Configuration of 1,11.
Transmitter Power 2*500mW~2×5W (ToC)
RX Sensitivity -123dBm(one-way RX),-126dBm(2-way RX)
Voice capacity UL:192CE; DL:192CE
Data capacity DL 84Mbps; UL 23Mbps
Transmission 1 electrical GE/FE +1 optical GE/FE, or 2 optical GE/FE;Body
Antenna
Sun shield
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 3
Transmission 1 electrical GE/FE +1 optical GE/FE, or 2 optical GE/FE;
Antenna Internal antenna (6dBi ) or external antenna
Volume, Weight Bare module: 12kg
+antenna and shield: 14kg
Power Supply 110-290V AC
Power consumption 160W(typical), 170W(Maximum)
Dimensioning and
weight
300mm*280mm*145mm , 13 kg
Temperature -40℃~ 50℃@without solar radiation;
-40℃~ 45℃@with solar radiation
Power connector
Optical port Electrical port
RGPS
Connector of exterior alarm
N female---Antenna
Maintenance cavity
Indicator light
UMTS Micro Physical Ports
Item Silkscreen Print Description
Bottom panels
ANTA_TX/RX TX/RX port A
ANTB_TX/RX TX/RX port B
ANTC_SON SON antenna port
ETH FE/GE electrical port
OPT0 FE/GE optical port
OPT1 FE/GE optical port
MONEnvironment monitoring port (for 485 input and four dry contact inputs)
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 4Page 4
inputs)PWR Power supply port
Maintenance panel DBG Port for commissioning, clock test,
or software upgrade
Indicator area
RUN Indicator for power input and board operating status
ALM Alarm indicator
ACT Indicator for the module operating status
VSWR Alarm indicator for the VSWR
O/E Indicators for OPT1 status or ETH status
O Indicator for OPT0 status
Scenario 1 Pole Mounted with Surge Protection in Outdoor Scenario for Wired Transmission
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 7
• This scenario is applicable to the city street coverage, coverage of the top of building, and the suburb/rural outdoor coverage.
Page 7
Scenario 2 Pole Mounted with Surge Protection in Outdoor Scenario for Wired Transmission
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 8Page 8
This scenario is applicable to the city street coverage, coverage of the top of building, and the
suburb/rural outdoor coverage.
Scenario 3 Wall Mounted with Surge Protection in Outdoor Scenario for Wired Transmission
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 9Page 9
This scenario is applicable to the city street coverage.
Outdoor MA5628Outdoor MA5628Outdoor MA5628Outdoor MA5628
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 10Page 10
Type Integrated Equipment
Dimension HxWxD:450mm×305mm×110 mmTemperature -40°C~55°C, -25°C startup
NNI 2 SFP, EPON/GPON
UNI 4GE/FE + 4E1
Environment IP65, wall-mounted
E1 Native TDM
Synchronization E1, Ethernet Synchronization
Power supply AC, no backup inside
Heat dissipation Natural cooling, no Fan
Protection 6kV anti-lightning