7/27/2019 HUAWEI OVERSHOOTING ANALYZE.pdf
http://slidepdf.com/reader/full/huawei-overshooting-analyzepdf 1/8
HUAWEI OVERSHOOTING CELLSANALYZE
By means of neighboring relations
and propogation delay data
overshooting analyze
7/27/2019 HUAWEI OVERSHOOTING ANALYZE.pdf
http://slidepdf.com/reader/full/huawei-overshooting-analyzepdf 2/8
• Under the performance menu click «Neighboring Cell Data Import»
• In the opened table click «import»
• From the NE part select RNC that you want to make analyze
• Select period as 60 Minutes or 24 Hours and set data range for the analyze time
7/27/2019 HUAWEI OVERSHOOTING ANALYZE.pdf
http://slidepdf.com/reader/full/huawei-overshooting-analyzepdf 3/8
• After importing done make a query for the related RNC and time range
• You will see following successfully imported datas
7/27/2019 HUAWEI OVERSHOOTING ANALYZE.pdf
http://slidepdf.com/reader/full/huawei-overshooting-analyzepdf 4/8
• Then go to Performance Query section
• Sellect measurement between a cell and UMTS cells counters
• Run the Query for the data imported date range and RNC with proper time period
7/27/2019 HUAWEI OVERSHOOTING ANALYZE.pdf
http://slidepdf.com/reader/full/huawei-overshooting-analyzepdf 5/8
• Get the export for the above mentioned query
• Make filter table and count number destination cell ID
• Sort it with the lagest number
• As showed in following table WGA31607 cell interacting with «110» cell
7/27/2019 HUAWEI OVERSHOOTING ANALYZE.pdf
http://slidepdf.com/reader/full/huawei-overshooting-analyzepdf 6/8
• Then go to Performance Query section again
• Sellect RRC connection setup measurement per cell
• Run the Query for the data imported date range and RNC with proper time period
7/27/2019 HUAWEI OVERSHOOTING ANALYZE.pdf
http://slidepdf.com/reader/full/huawei-overshooting-analyzepdf 7/8
• See the below mentioned propogation steps distance
• When we check serving distance for WGA31607 from exported query we can get
the following table that shows us it serves till step 10