3
Reliable UPS Against Poor Grid
Unavoidable grid problems
Blackout of Manhattan Blackout of USA and Canada
Harsh environment condition
Lightning Poor quality of grid
A variety of loadsPoor grid Damage of electrical device Adverse environment condition
4
Efficient UPS for Energy Saving
High efficiency, low power consumption
It is estimated that the annual power consumption of the data centers all over the world is up to 40,000,000,000 kW·h.
Energy consumption of typical data center
If the efficiency of UPS is improved from 90% to 92%, the power consumption decreasing for UPS itself is about 21.7% and cost saving for data center is about 0.5 billion kW·h, reducing about 20 million tons of carbon emissions.
Business grow with low OPEX
5
Huawei UPS Solutions
25-800kVA
30-800kVA
Small
Medium
1-20kVAUPS2000-G
UPS5000-E
UPS5000-A
UPS capacity Tower RT Modular Tower
Large
1-10kVAUPS2000-A
6
Capacity 1/2/3kVA 6/10kVA Standard Version6/10kVA Professional
Version
Appearance
Input : Output 1-in : 1-out
Model Standard ; long run Standard ; long run Standard ; long run
Parallel ---- ---- Support 4 UPSs in parallel
Maintenance Bypass
---- ---- Build-in
L-L 208V ---- ---- support
UPS2000-A (1-10kVA)
8
• LCD display
• Build-in battery
• Battery intelligent management, flexible configuration
• Integrated monitoring Platform for the whole network
UPS2000-A Core Value
• When working in online mode the efficiency is up to 96%
• High efficiency at low load rate
• Widest input voltage range
• 5kA lightning design
• Coating design and key device pin special protection Reliable
Efficient
Simple
9
• 1/2/3kVA Input voltage range: 110V to 300V
• 6/10kVA Input voltage range: 80V to 280V
Online double conversion, the wide input voltage range
Common Power Problems
Wide input voltage
EfficientReliable Simple
80V AC input 280V AC input Spike wave input Serious distortion wave input
High Adaptability to Extend Battery Life
Minimizes battery use to extend battery
lifespan.
10
125% overload for 5 minutes 150% overload for 30 seconds
supports 150% Overload
High Overload Capacity
Various Loads
• Output power factor: 0.9• Capacitive/inductive loads from
lead 0.5 to lag 0.5• High output load capacity ensuring
expansion demands in future
Supports various load
Electrical load with constant changes
High Overload Capacity Ensure Supply Quality
EfficientReliable
Reduces transfer times to bypass mode, ensuring customer equipment power supply quality.
server TV
ATM compressor
Simple
11
More than 70% of lightning accidents involve
the power supply system.
More than 90% of lightning accidents involve
computer network and communication
systems armed with UPS.
Unrecoverable hardware damage to IT equipment caused by lightning
5 kA lightning protection design by simulating actual lightning
Lightning design(Input common-mode)
HUAWEI 6 kV/5 kA
Traditional 4 kV/2 kA or none
Huawei UPS can prevent 90% of failures
caused by lightning by protecting equipment
input ports.
5 kA Lightning Protection Reducing Failure
EfficientReliable
Rocket-triggered lightening
Simple
12
To enhance reliability design, the system is safe and reliable
Coating
Coating design improves the ability to adapt to the harsh physical environment
dustproof
Preventing lateral diffusion of dust and enhancing thermal dissipation capacity
Pin protection
Special protection of vulnerable components helps reduce the failure rate and improve system reliability
√ × √ ×
EfficientReliable Simple
13
1,000 hours at 40℃
Temperature, Humidity, Bias (THB)Temperature: 40℃
Humidity: 95% for 1,000h
Temperature shocksampling test
High temperature test
-40°C to 70 ℃HALT
Highly accelerated life test
-60 to 110 ℃ ℃
5 cycles
Global Certification Test Center
Long Life Test (LLT)Temperature: 40℃
6 months
Open field
Hainan open field
Airborne hygroscopic dust , salt
spray environment
Shenzhen open field
Lightning test
Rocket-triggered lightening
5 kA Lightning
Strictest Testing — Higher Than Industry Standard
EfficientReliable Simple
14
Great Creative Topology, System Efficiency Is Up To 96%
90%
91%
92%
93%
94%
95%
96%
97%
10kVA UPS typical efficiency
Load rate
efficiency
•95%@25% load , high efficiency at low load rate•96%@50% load , energy saving
Typical load of 9kW , electric charge=0.16USD/kWh
Legacy UPS Present UPS in the industry
Huawei UPS
UPS Efficiency 85% 90% 95.8%UPS power dissipation per year(kWh) 13912 8760 3456
Total power cost per year(USD) 2226 1401 552
Power cost over HUAWEI UPS (USD) 1674 849 0
Patent topology , the No.1 system efficiency
0500
1000150020002500
Yearly Power Cost/USD
Cost reducing by 75%
EfficientReliable Simple
15
Built-in battery
• Super small volume, more suitable for
office,bank branches and so on
• Output interface is IEC socket , easy to
use
Flexible Backup Time Solutions
EfficientReliable Simple
External charger
0 1 2 3 4 5 6 7 8 936V charger 1A 3A 6A 9A 12A 15A
72V charger 1A 2A 4A 6A 8A 10A 12A
96V charger 1A 2A 4A 6A 8A 10A
The corresponding gear of the charging current
16
• Friendly Interactive Interface
• Parameters can be set through the panel, convenient and easy
LCD display, Easy Configuration And Management
Working Mode
Battery Capacity
Load rate
Working status
Setting menuOutput voltage level , Output frequency system ,Number of batteries , Total battery capacity , Charge current limit, Discharge time protection setting etc.
Active alarm display menuActive alarm information, including the alarm No, alarm ID, and alarm cause ID
Control menu Starts or shuts down the inverter, clears ADMC alarms, replaces batteries, synchronizes parallel parameters, and restores default settings
Historical alarm display menuDisplaying the latest 10 alarms
EfficientReliable Simple
17
Built-in maintain bypass to improve the maintainability Professional Version: Up to four units, easy to expand
• Auto-sensing parallel, easy to form N + X configuration
• The ring parallel line eliminates the failure of a single parallel
cable
• Only professtional 6/10kVA can support parallel
Up to Four parallel
Ring parallel line
• Protection lock , avoid maintenance bypass switch
was wrong operation
• Maintenance is convenient, simple and easy
Maintain bypass break
Protective lock
EfficientReliable Simple
18
Flexible Configuration and Maintenance Senior Management
• 20 to 16 cells per string for 6K/10K; 32 to 40 cells per string for 15/20K. When removing damaged batteries, the remaining batteries will work normally.
Damaged battery due to thermal runaway
• Automatic identification of electrical environment, enabling intelligent hibernation mode in a healthy grid.
• Detects battery states in real time and supports battery pre-alarm.
Old batteries can be reused.
Intelligent Management to Extend Battery Life
Intelligent Charge and Discharge
• Automatic equalized and float-charging conversion and temperature compensation function prevent battery over- or under-charging to extend battery life.
• Automatically adjusts discharge termination voltage in accordance with load condition and the discharge time.
Battery discharging curve
Battery voltageConstant voltage
Temperature compensation
Battery hibernation
×
EfficientReliable Simple
19
•Monitoring unit supports remote online
upgrade.
•Supports RS485, SNMP, USB, and dry
contact.
•Displays real-time system running state.
•Power supply and battery testing systems can
be controlled.
Remote online upgrade
Easy to manage
Integrated Monitoring System, easy remote management
NetEco 1000U
interface
USB SNMPModbus Dry contact
• Compact and easy to use, can be plugged into the USB
port
• Supports UPS real-time status inquiry via SMS
• Can be set to send UPS status and alarm information
timely
GSM
Modem
EfficientReliable Simple
21
UPS Ports Introduction—1kVA
Standard ( Oversea ) Long Run ( Oversea )
国内版的输出插座
1. AC input socket 2.Input Socket Breaker 3. USB 4. RS-232
5 .Monitor card slot(optional) 6.External battery access 7. AC output socket 8. LCD Display Panel
9. Control Button
22
国内版的输出插座
UPS Ports Introduction—2kVA
Standard ( Oversea ) Long Run ( Oversea )
1. AC input socket 2. Input Socket Breaker 3. USB 4. RS-232
5. Monitor card slot(optional) 6. External battery access 7. AC output socket 8. LCD Display Panel
9. Control Button
23
国内版的输出插座
1. AC input socket 2. Input Socket Breaker 3. USB 4. RS-232
5. Monitor card slot(optional) 6. External battery access 7. AC output socket 8. C19 output socket
9. LCD Display Panel 10. Control Button
UPS Ports Introduction—3kVA
Standard ( Oversea ) Long Run ( Oversea )
24
(1) AC input circuit breaker (2) Optional card slot (3) USB port (4) MBS port
(5) EPO port (6) AC input terminal block (7) AC output terminal block (8) Battery wiring terminal block
UPS Ports Introduction—6/10kVA Standard Version
Standard Long-run
25
(1) AC input circuit breaker (2) Optional card slot (3) EPO port (4) USB port
(5) MBS port (6) Parallel port(7) Maintenance bypass circuit breaker
(8) AC output circuit breaker
(9) AC input terminal block(10) Jumper terminal block for a single UPS or a parallel system
(11) AC output terminal block
(12) Battery wiring terminal block
UPS Ports Introduction—6/10kVA
professional versionStandard Long-run
27
No. Parameter Huawei UPS2000-A-6/10kVA Emerson GXE-6/10kVA Influence
1 Input voltage range 80-280Vac 120-288Vac Narrow input range increases battery use, shortening battery lifespan.
2 Output power factor 0.9 0.8 can't match the new IT load, increase the investment by the user
3Output Voltage accuracy 1% 3% Low output precision, can not better
protect user load
4 Efficiency 96% 91% More energy consumption, increased operating expenses
5Charging current(Long run )
8A4A
Charging current is small, cannot satisfy the bad power grid or longtime backup
6 Battery Voltage192-240V(can be set )
192V If one battery is damaged, the entire group of battery scrap
7 Reliability5 kA lightning protection, veneer coating, special protection for key device pin, pre-alarm for key component
2 kA lightning protectionLack of reliability may cause huge losses to the user
Emerson GXE
28
No. Parameter Huawei UPS2000-A-6/10kVA EATON CASTLE-6/10KVA Influence
1 Panel LCD LED light Unfriendly interface
2 Input voltage range 80-280V 120-275VNarrow input range increases battery use, shortening battery lifespan.
3 Charging current(Long run )
8A 4ACharging current is small, cannot satisfy the bad power grid or longtime backup
4Output Voltage accuracy 1% 2% Low output precision, can not
better protect user load
5 Efficiency 96% 94% More energy consumption, increased operating expenses
6 Over load 105%-125% 5min 105%-125% 1min
7 Reliability5 kA lightning protection, veneer coating, special protection for key device pin, pre-alarm for key component
2 kA lightning protectionLack of reliability may cause huge losses to the user
EATON CASTLE
29
Contents
11
44
33
22
HighlightsHighlights
Product introductionProduct introduction
Competitive strengths
Competitive strengths
Optional accessories Optional accessories
31
UPS2000-A Optional Accessories
Battery switch box
Dry Contact Card
SNMP card
Modbus card
Dry contact card
Temperature and humidity sensor
Transformer
Battery pack
UPS2000-A
GSM Modem
Battery box
Battery Rack
External Charger
1/2/3kVA 6/10kVAUPS fixing stand
32
Optional Accessories-Battery Pack for 1/2/3kVA
Backup
timeSpecifications Number
17min ESS-72V12-9AHBPVBB 1PCS
39min ESS-72V12-9AHBPVBB 2PCS
Backup
timeSpecifications Number
17min ESS-96V12-9AHBPVBB 1PCS
39min ESS-96V12-9AHBPVBB 2PCS
Backup
timeSpecifications Number
15min ESS-36V12-9AHBPVBB 1PCS
36min ESS-36V12-9AHBPVBB 2PCSUPS2000-A Battery Pack
1K: Backup time of battery pack(100%load)
2K: Backup time of battery pack(100%load) 3K: Backup time of battery pack(100%load)
33
ESS-240V12-2*9AhBPVBA01*2
load (% ) load (W )1battery box backup time
2battery box backup time
100% 9000 12 28
80% 7200 15 40
60% 5400 23 52
40% 3600 40 79
ESS-240V12-2*7AhBPVBA01
load (% ) load (W )1battery box backup time
2battery box backup time
100% 5400 17 41
80% 4320 23 50
60% 3240 32 70
40% 2160 50 106
Optional Accessories-Battery box for 6/10kVA
10K: Backup time schedule of battery box
6K: Backup time schedule of battery box
UPS2000-A 6/10kVA battery box
34
MODBUS Card Dry Contact Card
UPS2000-A Card slot can hold three types of monitoring cards: Modbus card and Dry contact card
•Support the MODBUS RTU
communication protocol
•Provide the RS - 485 interface
•Support hot plug, convenient installation
•Provide contact signal, can remotely
monitor the UPS
Optional Accessories –Monitoring Card for 1/2/3kVA
Monitoring card slot
35
Optional Accessories –Monitoring Card for 6/10kVA
SNMP card
•Monitors, via NMS, NetEco, and the Web, the UPS.
operating status based on the computer network type.
• Environment temperature and humidity sensor can be
inserted in
SNMP to monitor surrounding information.Modbus card
• RS485 networking.
• Monitoring via the NetEco 1000U.
• Only one card required in parallel system.
Dry contact card
• 6 alarm outputs :( Normal mode , battery mode ,
bypass mode , Low battery voltage, Bypass
backfeed ,
UPS faults )
• 2 control inputs : Shutdown , reserved.
Card slot can hold three types
of monitoring cards.
Monitoring card slot
36
Optional Accessories –Battery Rack and Switch Box
Battery rack
Battery switch box
More connection type of battery racks
•Type of battery rack depends on
battery number and capacity.
Model Specifications UPS
PDC-63DC-440V 440VDC 63A 3/6/10kVA
+
-+
-
+ - + - + -
UPS
Rack 1 Rack 2 Rack 3 Rack 4
more battery racks connections
37
Optional Accessories –External charger
External charger side and LED indicator
1 DC connector 2 Status indicators3 Current selection switch 4 Power switch5 Mains input
Match with UPS
Status Indicator
In boost state
In float state
The On and Boost indicators are on.The On and Float indicators are on.
Full level50%Low level
The Full indicator is on.The MID indicator is on.The LOW indicator is on.
Independent use
Current selection switch36V charger 15A(max)72V charger 12A(max)96V charger 10A(max)
38
Optional Accessories - Transformer
Functions • Realize electric isolation
• Transformer ratio 2:1:1
• Output dual 110V or another 220V
Types• 6kVA transformers for 6K UPS
•10kVA transformers for 10K UPS
39
Optional Accessories -NetEco 1000U
• Real-time monitoring. NetEco 1000U monitors UPSs in real
time and allows users to configure and control UPSs
• Delay shutdown, shut down the computer application system
and operating system
• USB, SNMP, Modbus networking communication
• Historical data query. Query historical data and UPS alarm logs
through the NetEco 1000U.
• Remote alarm notification. NetEco 1000U notifies users via by
emails or SMS short messages immediately after a UPS
reports an alarm
The free NetEco 1000U can only support monitoring within ten UPSs.
An installation CD of NetEco 1000U is delivered with the UPS.
40
SpecificationCapacity ( kVA/kW ) 1/0.8 2/1.6 3/2.4 6/5.4 10/9
Input : Output 1-in : 1-out 1-in : 1-outInput
Mains
Rated Voltage 200/208/220/230/240 VAC 220/230/240 VACInput Voltage Range 110-300 VAC 80-280VACInput Frequency Range 40-70 Hz 50/60±5HzInput Power Factor > 0.99 >0.99
BatteryBattery voltage
Standard 24 V 48V 72 V 192 VLong run 36 V 72 V 96V 192-240V
OutputOutput Wiring Ph+N+PE Ph+N+PE
Output Sockets4 *IEC
C13(10A) 6*IEC C13(10A)6*IEC
C13(10A)— —
Rated Voltage 200/208/220/230/240 VAC ±1%220/230/240 VAC ±1% ( Standard version )208/220/230/240 VAC ±1% ( Professional version )
Rated Frequency 50/60±3Hz 50/60±5HzOutput Power Factor 0.8 0.9
Waveform < 3% ≤2%Efficiency 88% 89% 90% 96% 96%
EnvironmentalOperating temperature 0°C–40°C
Audible noise <50dB @ 1 Meter <50dB @ 1 MeterOthers
CertificationsYD/1095-2008 , EN/IEC 62040-1 , EN/IEC 62040-2 ,
EN/IEC 61000,CE, CB ,TLC
YD/1095-2008 , EN/IEC 62040-1 , EN/IEC 62040-2 ,EN/IEC 61000 , CE , CB , Rohs , TLC
Reach ,WEEECommunications RS485/Dry contact RS485/USB/Dry Contact/SNMP
41
Optional accessoriesMode
List UPS2000-A-1kTTSUPS2000-A-2kTTSUPS2000-A-1kTTS
UPS2000-A-1kTTLUPS2000-A-2kTTLUPS2000-A-1kTTL
UPS2000-A-6kTTS-SUPS2000-A-10kTTS-S
UPS2000-A-6kTTL-SUPS2000-A-10kTTL-S
UPS2000-A-6kTTS-PUPS2000-A-10kTTS-P
UPS2000-A-6kTTL-PUPS2000-A-10kTTL-P
Battery pack √
Battery box √ √ √
Battery Rack √ √ √
BCB box √ √ √
External charger √ √
SNMP/Mobus/dry contact
√ √ √ √ √ √
High voltage protection √ √
Anti-tilt mechanical part √ √ √ √
Outputtransformer
√ √
GSM modem √ √ √ √
Environment temperature and humidity sensor
√ √ √ √ √ √
Parallel cable √ √
THANK YOU
Copyright©2016 Huawei Technologies Co., Ltd. All Rights Reserved.The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.