Humidity Humidity sensors - Vapour pressure and dew point temperature - Soil moisture sensors - Leaf wetness sensors. Electrical RH Sensors. Capacitance changes with RH – thin layer of hygroscopic polymer between two capacitance plates - almost linear - ~2% accuracy to 90% RH, then ~3%. - PowerPoint PPT Presentation
26
Humidity - Humidity sensors - Vapour pressure and dew point temperature - Soil moisture sensors - Leaf wetness sensors
Transcript
Page 1: Humidity

Humidity

- Humidity sensors- Vapour pressure and dew point temperature- Soil moisture sensors- Leaf wetness sensors

Page 2: Humidity

Electrical RH Sensors

• Capacitance changes with RH – thin layer of hygroscopic polymer between two capacitance plates - almost linear- ~2% accuracy to 90% RH, then ~3%

Page 3: Humidity

Figure from Brock and Richardson

Page 4: Humidity

Electrical RH Sensors

• Resistance changes with RH… a “hygristor”

- less accurate - responds differently to increasing versus decreasing RH (hysteresis error)

Also a thermistor in this RH/Temperature sensor

Page 5: Humidity

What is relative humidity (RH)?

Curve shows max possible vapour pressure

Current conditions plotted as “A”T = 35 C, VP = 28 hPa

“B” is max possible vapour pressure at 35 C = 56 hPa

RH in % = current VP Max possible VP

X 100

RH = (28 / 56) x 100 = 50%

Page 6: Humidity

RH depends on vapour content and temperature, so temperature variations will change RH even when the vapour pressure of the atmosphere is constant.

Page 7: Humidity

Let’s check to see how much the actual water content of the atmosphere changed from 6am to 3pm on this day, by computing the vapour pressure (e) at the two times.

At 6am: T=10C, RH = 90%

Max e @ 10C = 12.3 hPaSo e = 0.90 x 12.3 =11.1hPa

At 3pm: T=25C, RH = 35%

Max e @ 35C = 31.7 hPaSo e = 0.35 x 31.7 =11.1hPa

Page 8: Humidity

Exposure of Humidity Sensors

• Shield RH sensors – must be at correct air temperature to give correct RH

• Filters on RH sensors- keep dry - keep clean so they do not lower the ventilation rate and increase the risk of radiation error

Page 9: Humidity

The concept of “dew point temperature”

The temperature to which air must be cooled to initiate condensation.

Current conditions are plotted at “A”…T = 35 C, VP = 28 hPa

Imagine we cool the air along the path A –D. At “D” we reach the max possible VP line, which is where condensation will begin.

The temperature at “D” is the dew point temperature, about 21 C.

Page 10: Humidity

Since e = es@Td, & RH = e / es@T, then RH =es@Td / es@T

1. The weather channel shows the following conditions at Halifax airport: T = 23.2 C, Dew point = 14.7 C

What is the relative humidity?

2. Your T/RH probe reads T = 17.4 C, RH = 72.4%

- what is the dew point temperature?

RH = es@Td / es@T = 16.7 hPa / 28.4 hPa = 0.588 or 58.8%

es@Td = RH x es@T = 0.724 x 19.9 hPa = 14.4 hPaUsing SVP table, 14.4 hPa matches 12.4 C, which is Td.

Page 11: Humidity

Radiation absorption hygrometers

Allow air to flow between a radiation source and a detector. Choose source emission at a wavelength that is absorbed by water vapour (usually in the ultra-violet or infra-red regions)

This is a “Krypton Hygrometer”

• Krypton lamp in one head emits U.V. radiation that is absorbed by water vapour.

• U.V. detector in other head senses the fluctuating concentration of water vapour in air that blows through the gap between U.V. emitter and detector.

U.V. emitter

U.V. detector

Source

Detector

Air flow

Page 12: Humidity

Radiation absorption hygrometers used for Eddy Covariance flux measurements

• Can detect rapid fluctuations in water vapour

• Used to make measurements of evaporation of water from land or water surfaces into the air, in combination with fast response wind sensor.

• E = Vapour concentration x Vertical wind component = kg/m3 x m/s = kg evap /m2 each second.

• Technique can also be used with fast response infra-red absorption CO2 sensor to get CO2 flux.

Fast response H20 or CO2 sensor

Fast response wind sensor

Page 13: Humidity

Soil Moisture

(Strangeways – Fig. 9.9)

Time domain reflectometry (TDR)

Signal sent down probes bounces back (reflects) when it reaches the ends of the probes.

Time required to travel down and back depends on the moisture content of the material between the probes.

Can insert the probes…- vertically, to average over a depth of soil- horizontally, to average over a horizontal layer- diagonally, for combined vertical and horizontal average.

Page 14: Humidity

Leaf Wetness Sensors

• Grid of interlaced, but non-contacting, conducting fingers

• Presence of rain or dew water changes the resistance or capacitance between the fingers wetness signal

Page 15: Humidity

Decagon leaf wetness sensor

Growers use data on duration of leaf wetness, and temperature during the wet period, to decide if a fungicide spray is needed.

Results in fewer sprays, and lower chemical costs… a win for both the grower and the environment.

Page 16: Humidity
Page 17: Humidity

The wet and dry bulb psychrometer.

Cooling of the wet bulb by evaporation is related to the dryness of the air (drier air, more cooling).

So e = eSW - 0.65(T-Tw)

Calibration of RH probes

Suppose you measure a dry bulb temperature of 20.2 C and a wet bulb of 17.3 C.

What is the RH?

Page 18: Humidity

A high-quality “Assman” shielded and ventilated psychrometer.

Thermometer bulbs are shielded from radiation

Air is drawn past the thermometer bulbs by a spring-

driven fan

Page 19: Humidity

Dew point hygrometer

Page 20: Humidity

Calibration requires generation of known water vapour content in air (Fig 5-17)

Page 21: Humidity

Suppose you take a psychrometer or other well-calibrated RH sensor that is shielded & ventilated to the field to check a T/RH probe at your weather station.

•But it’s a calm day, and the weather station probe is in an unventilated shield, so it is suffering a radiation error, and is reading a higher temperature than your calibration unit.

• If the RH sensor in the weather station probe is working correctly, why won’t it give the same value as the RH from your calibration unit?

• How could we still check the accuracy of the weather station RH sensor in this situation? (Hint: the actual VP is unaffected by a radiation error.) Can we check the accuracy of the station T-sensor?

Page 22: Humidity
Page 23: Humidity

Ventilated psychrometer in a “Stevenson Screen” thermometer shield

Fan on roof sucks air through the tube that surrounds the thermometers.

Page 24: Humidity
Page 25: Humidity

Bare grids lack sensitivity…

• Coat with latex paint (transmits water to grid for good response)

• Allows colour adjustment to match drying of leaves. Lighter visible colour than real leaves needed because paints do not match the high reflectivity of leaves in solar infra-red wavelengths.

Page 26: Humidity

Delayed response of unpainted leaf wetness sensors


Recommended