Core VFD Series | p. 695 FCXLS/NFCXLS | p. 692PSR Series | p. 681
Kele Has Soft Starters and VFDs to Extend the Life of Your Motor and Help Save Energy and Maintenance Costs.
MODEL/SERIES PAGEProducts manufactured in the United States
Products that are new to the catalog
ke le .com
MOTOR CONTROLS
A Series | p. 683
TEC Compact | p. 687 Starters
Smart VFD | p. 704 HVAC
MO
TO
R
CO
NT
RO
LS
Motor DisconnectsABB EOT Series — Enclosed Non-Fused Disconnect Switch . . . . . . . . . . . . .689BCXLS Series — Breaker Combination Motor Starters . . . . . . . . . . . . . . . . . .690FCXLS, NFCXLS Series — Fusible and Non-Fusible Motor Starters . . . . . . .692 Motor StartersPSR Series — Softstarters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .681A Series — ABB 3 Phase Motor Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .683TEC Compact Starters — 3 Phase Motor Starters . . . . . . . . . . . . . . . . . . . . .687 Variable Frequency Drives (VFD) and BypassesCORE VFD — Honeywell Variable Frequency Drives . . . . . . . . . . . . . . . . . . . .695CORE VFD With Bypass — Honeywell Variable Frequency Drives . . . . . . . . .698SmartDrive Compact VFD — Honeywell Compact Variable Frequency
Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .702SMARTVFD HVAC — Honeywell All Purpose Variable Frequency Drives . . . .704SMARTVFD HVAC With Bypass Assembly — Variable Frequency Drives
with Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .707
NEW!
681
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
Model PSR3 - 16 with MCCB Model PSR25 - 45 with MCCBL/+ N/C
PSR
Fuse(customersupplied)
Circuitprotection
by customer
Note: verify motor nameplatevoltage and horsepowerrating for soft starter selection
Sup
ply
Vol
tage
CO
M L/+ N/C
PSR
Fuse(customersupplied)
Circuitprotection
by customer
Note: verify motor nameplatevoltage and horsepowerrating for soft starter selection
Sup
ply
Vol
tage
CO
M
SOFTSTARTERSPSR SERIES
DESCRIPTION
Constant-speed AC motors are used to drive HVAC fans and pumps . During start and stop, both mechanical and electrical stresses are high, causing undesirable load peaks each time the motors are started . An ABB Softstarter eliminates many of these problems . The voltage is smoothly applied to, and removed from, the motor . Both the torque and the current consequently behave in the same way . The result is that mechanical and electrical stresses are significantly lower than with conventional starting methods .
The PSR series Compact Softstarters range covers motor currents from 3 to 46A . All sizes include a Run signal relay . The 25A and above are also provided with an output signal for TOR (Top Of Ramp, i .e . full voltage) . With standard performance the PSR Softstarters handle ten starts per hour . When an auxiliary cooling fan is added, the starting capacity is increased to 20 starts per hour .
FEATURES
• Compact size• Easy to install and adjust• DIN rail or screw mounting
Supply Voltage 100/ 240 V, 24 VDCMotor Voltage Rating 208 to 600 VACCurrent Rating PSR3 3 .9A Starting capacity 15 .6A for 6s PSR6 6 .8A Starting capacity 27 .2A for 6s PSR9 9A Starting capacity 36A for 6s PSR12 12A Starting capacity 48A for 6s PSR16 16A Starting capacity 64A for 6s PSR25 25A Starting capacity 100A for 6s PSR30 30A Starting capacity 120A for 6s PSR37 37A Starting capacity 148A for 6s PSR45 46A Starting capacity 180A for 6sHorsepower Based on rated Voltage and FLA
Acceleration Time 1-10 secondsDeceleration Time 0-20 secondsAltitude Limits 13,123 ft . (4000 m)Protection Rating Main circuit IP20 Control Circuit IP20LED Indication On/ Ready Green On/ Ready Green
Run/ Top of Ramp Green Run/ Top of Ramp Green
Operating Temperature -13° to 140°F (-25° to 60°C)Storage Temperature -40° to 158°F (-40° to 70°C)Number of Starts/ hr 10 standard; 20 with Aux . FanApprovals UL ListedFile E161428Warranty 12 months from installation,
maximum 18 months from factory
SPECIFICATIONS
WIRING
PSR30-600-70PSR45-600-70PSR16-600-70
• Run signal relay• 25A and above includes "Top Of Ramp" output signal• Motor ratings up to 600 VAC and 40Hp• Seperate Acceleration/ Deceleration times
NEW!MOTOR CONTROLS
682
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
SOFTSTARTERSPSR SERIES
ORDERING INFORMATION
ACCESSORIESPSR-FAN Cooling Fan for increased starting capacity (field-installable)
ModelControl Supply Voltage
Full Load Amps
Horsepower Circuit Breaker
Max.Fuse Size Dimensions Weight
208V 240V 480V 600V
PSR3-600-70 100/ 240 V 3.4 .5 0.75 2 2 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR6-600-70 100/ 240 V 6.1 1 1.5 3 5 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR9-600-70 100/ 240 V 9 2 2 5 7.5 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR12-600-70 100/ 240 V 11 3 3 7.5 10 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR16-600-70 100/ 240 V 15.2 3 3 10 10 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR25-600-70 100/ 240 V 24.2 7.5 7.5 15 20 50 A 40 A J-Type6.30" x 1.77" x 5.04"
(160mm x 45mm x 128mm)1.43 lbs.(0.65 kg)
PSR30-600-70 100/ 240 V 28 7.5 7.5 20 25 50 A 40 A J-Type6.30" x 1.77" x 5.04"
(160mm x 45mm x 128mm)1.43 lbs.(0.65 kg)
PSR37-600-70 100/ 240 V 34 10 10 25 30 50 A 40 A J-Type7.36" x 1.77" x 6.02"
(187mm x 45mm x 153mm)2.20 lbs.(1.00 kg)
PSR45-600-70 100/ 240 V 46.2 15 15 30 40 50 A 40 A J-Type7.36" x 1.77" x 6.02"
(187mm x 45mm x 153mm)2.20 lbs.(1.00 kg)
PSR3-600-81 24 VDC 3.4 .5 .5 2 2 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)2.20 lbs.(1.00 kg)
PSR6-600-81 24 VDC 6.1 1 1 3 5 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR9-600-81 24 VDC 9 2 2 5 7.5 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR12-600-81 24 VDC 11 3 3 7.5 10 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR16-600-81 24 VDC 15.2 3 3 10 10 50 A 40 A J-Type5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)
PSR25-600-81 24 VDC 24.2 7.5 7.5 15 20 100 A 60 A J- Type6.30" x 1.77" x 5.04"
(160mm x 45mm x 128mm)1.43 lbs.(0.65 kg)
PSR30-600-81 24 VDC 28 7.5 10 20 25 100 A 70 A J- Type6.30" x 1.77" x 5.04"
(160mm x 45mm x 128mm)1.43 lbs.(0.65 kg)
PSR37-600-81 24 VDC 34 10 10 25 30 150 A 100 A J- Type7.36" x 1.77" x 6.02"
(187mm x 45mm x 153mm)2.20 lbs.(1.00 kg)
PSR45-600-81 24 VDC 46.2 15 15 30 40 150 A 100 A J- Type7.36" x 1.77" x 6.02"
(187mm x 45mm x 153mm)2.20 lbs.(1.00 kg)
NEW!
683
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
MODEL SIZEA9, A16
A26
A50, A75
A145
A260
5.3"H x 1.7"W x 3.7"D(13.3 x 4.4 x 9.5 cm)
5.8"H x 2.1"W x 4.3"D(9.0 x 2.1 x 11.0 cm)
6.9"H x 2.8"W x 4.4"D(17.7 x 7.0 x 11.3 cm)
12.9"H x 4.1"W x 6.3"D(32.9 x 10.5 x 16.0 cm)17.5"H x 5.5"W x 7.1"D(44.4 x 14 x 18.1 cm)
Open Frame Starters in (cm)
Enclosed Starters in (cm)
NEMA 111"H x 6"W x 5"D
(27.9 x 15.2 x 12.7 cm)13"H x 9"W x 7"D
(33.0 x 22.9 x 17.8 cm)30"H x 24"W x 12"D
(76.2 x 61.0 x 30.5 cm)30"H x 24"W x 12"D
(76.2 x 61.0 x 30.5 cm)
NEMA 1 fused14"H x 12"W x 8"D
(35.6 x 30.5 x 20.3 cm)20"H x 16"W x 8"D
(50.8 x 40.6 x 20.3 cm)30"H x 24"W x 12"D
(76.2 x 61.0 x 30.5 cm)36"H x 30"W x 12"D
(91.4 x 76.2 x 30.5 cm)
NEMA 1 circuit breaker14"H x 12"W x 8"D
(35.6 x 30.5 x 20.3 cm)14"H x 12"W x 8"D
(35.6 x 30.5 x 20.3cm)24"H x 20"W x 8"D
(61.0 x 50.8 x 20.3 cm)30"H x 24"W x 12"D
(76.2 x 61.0 x 30.5 cm)
MODEL SIZEA9, A16, A26
A50, A75
A145
A260
DESCRIPTION
The A Series ABB starter line offers motor start/stop and protection . The double-break contacts allow stopping a motor with minimal conact wear . The thermal overloads are sized for the motor FLA and keep motor windings from over-heating during overload conditions . We offer these starters in open, enclosed, enclosed with fusible disconnect, and enclosed with circuit breaker . Auxiliary contacts are available for field installation .
FEATURES
• NEMA sizes 00 thru 5• UL508A panel program, file #E105450• Compact space-saving design• Auxiliary contacts available• Coil operates 85 to 110% of rated voltage• Solid-state adjustable overload relays standard• Conventional bimetallic overloads available
DIMENSIONS
ABB 3 PHASE MOTOR STARTERA SERIES
A50NSF1-84A6B A9NS1-81E
NEW!MOTOR CONTROLS
684
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
ABB 3 PHASE MOTOR STARTERA SERIES
All units ship with a NO and NC contacts.Additional contacts can be added in the field.
Incoming LinesL1
L1 L2 L3
Incoming LinesL1 L2 L3
DisconnectFuse
Disconnect Breaker
1
X1
L1 L2 L3
T1M
F R
OL
OL
OL
T2 T3
T1 T2
MOTOR
MOTOR
T3
X2
3 5 1
External ControlSupply Standard 120 VAC
External ControlSupply Standard 120 VAC
CX1
2-1 1-1
3-4 3-4
3-2 3-2
3-13-7
3-7
3-6
3-5
3-3
3-6
3-3
1-2 2-2
2-1 1-1 1-2 2-2
CX23 5
98
JUM
PE
R
97
OL9695
OLM
Remote ContactCustomer
*
15
A1 A2
14
1 2
2 4 6
2 4 6
L1 L2 L3 L1 L2
X1
X2
L3
T1 T2 T3
T1 T2 T3
T1 T2 T3
DisconnectFuse
Disconnect Breaker
1 3 5 1 3 5
2 4 6
2 4 6
CX1 CX2
3-4 3-4
3-2 3-2
JUM
PE
R
FA1 A2F
F14 13
0121
0122
0121
0122
R
F
R
R
14 13
RA1 A2
Remote ContactCustomer
*
*
13 42
Non-reversing, reversingAF09 - AF750, AFN00 - AFN4
WIRING
NEW!
685
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
ABB 3 PHASE MOTOR STARTERA SERIES
All units ship with a NO and NC contacts.Additional contacts can be added in the field.
2-1 1-1
3-4
Jumper
3-4
3-2 3-2
3-7
3-3
3-5
3-9
3-6
1-2 2-2
2-1 1-1 1-2 2-2
DisconnectIncoming Lines
L1
SOL
SOL FOL SS
F
F
SF
S*
*F
S F
FOL
L2 L3
FuseDisconnect
External ControlSupply Standard 120VAC
Remote ContactCustomer
Breaker
1
X1L1 L2 L3 L1 L2 L3
T1 T2 T3 T1 T2 T3
T1
9514 13
14
3 1 2 4
13
96 95 96
T1 T11MOTOR*T2 T12T13
T2 T3 T1 T2 T3
X2
3 5 1
CX1 CX2
3 5
2 4 6
2 4 6
DisconnectFuse
Disconnect Breaker
1 3 5 1 3 5
2 4 6
2 4 6
0121
0122
0121
0122
A1 A2
A1 A2
3-2 3-2
3-7
3-3
3-53-9
3-6
SOL FOL95 96 95 96
S
2F14 13
14 13
1F
S0121
0122
0121
0122
2F
1F
14 13
21 22
S*
*F
Remote ContactCustomer
3 1 2 4
A1 A2
2F
1F
A1 A2
SA1 A2
Jumper
3-4 3-4
External ControlSupply Standard 120VAC
CX1 CX2
2 speed, 1 winding; 2 speed, 2 windingAF09 - AF75
WIRING
NEW!MOTOR CONTROLS
686
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
ORDERING INFORMATION
NEMASIZE00
0
1
2
3
4
5
200V–––
1/3, 1/41/23/4–1
1.5–23–5
7.5––10–152025––30405060–
230V–
1/41/31/2–
3/41
1.5––23–5
7.5–1015––20
25, 30––4050–60100
460V1/4
1/3, 1/23/41–
1.5, 2–––35–
7.510–152025–304050–6075100–
125200
575V1/2–
3/41
1.5, 2––––5––10––2025–304050–6075100–
125150–
OVERLOADRELAY
SETTINGRANGE
0.63 - 1.01.0 - 1.41.3 - 1.61.7 - 2.42.2 - 3.12.8 - 4.03.5 - 5.04.5 - 6.56.0 - 8.54.5 - 6.56.0 - 8.57.5 - 1110 - 1413 - 1918 - 2518 - 2522 - 3229 - 4229 - 4236 - 5245 - 6360 - 8065 - 9065 - 9065 - 9065 - 90
110 - 150130 - 185220 - 310
MODELOPEN STYLE
A9N00S-*EA9N00S-*FA9N00S-*GA9N00S-*HA9N00S-*JA9N00S-*KA9N00S-*LA9N00S-*MA9N00S-*NA16N0S-*MA16N0S-*NA16N0S-*PA26N1S-*QA26N1S-*RA26N1S-*SA50N2S-*AA50N2S-*BA50N2S-*CA75N3S-*CA75N3S-*DA75N3S-*EA75N3S-*F
A145N4S-*RA145N4S-*AA145N4S-*BA145N4S-*CA260N5S-*TA260N5S-*AA260N5S-*C
MODELNEMA 1
ENCLOSEDA9NS1-*EA9NS1-*FA9NS1-*GA9NS1-*HA9NS1-*JA9NS1-*KA9NS1-*LA9NS1-*MA9NS1-*N
A16NS1-*MA16NS1-*NA16NS1-*PA26NS1-*QA26NS1-*RA26NS1-*SA50NS1-*AA50NS1-*BA50NS1-*CA75NS1-*CA75NS1-*DA75NS1-*EA75NS1-*F
A145NS1-*RA145NS1-*AA145NS1-*BA145NS1-*CA260NS1-*TA260NS1-*AA260NS1-*C
FUSECLIPSIZE
CLASSJ
30A30A30A30A30A30A30A30A30A30A30A30A30A30A30A60A60A60A100A100A100A100A400A400A400A400A400A400A400A
MODELNEMA 1ENCL.
FUSIBLEDISCONNECTA9NSF1-*E6AA9NSF1-*F6AA9NSF1-*G6AA9NSF1-*H6AA9NSF1-*J6AA9NSF1-*K6AA9NSF1-*L6AA9NSF1-*M6AA9NSF1-*N6A
A16NSF1-*M6AA16NSF1-*N6AA16NSF1-*P6AA26NSF1-*Q6AA26NSF1-*R6AA26NSF1-*S6AA50NSF1-*A6BA50NSF1-*B6BA50NSF1-*C6BA75NSF1-*C6CA75NSF1-*D6CA75NSF1-*E6CA75NSF1-*F6C
A145NSF1-*R6EA145NSF1-*A6EA145NSF1-*B6EA145NSF1-*C6EA260NSF1-*T6EA260NSF1-*A6EA260NSF1-*C6E
MODELNEMA 1ENCL.
W/CIRCUITBREAKER
A9NSM1-*E4AA9NSM1-*F4AA9NSM1-*G4AA9NSM1-*H4AA9NSM1-*J4BA9NSM1-*K4BA9NSM1-*L4CA9NSM1-*M4CA9NSM1-*N4C
A16NSM1-*M4CA16NSM1-*N4CA16NSM1-*P4DA26NSM1-*Q4DA26NSM1-*R4DA26NSM1-*S4EA50NSM1-*A4EA50NSM1-*B4EA50NSM1-*C4EA75NSM1-*C4EA75NSM1-*D4FA75NSM1-*E4FA75NSM1-*F4F
A145NSM1-*R4FA145NSM1-*A4FA145NSM1-*B4FA145NSM1-*C4FA260NSM1-*T4HA260NSM1-*A4HA260NSM1-*C4J
CIRCUITBREAKER
RATING(480 V MAX)
33335510101010102525255050505050100100100100100100100250250400
MOTOR HORSEPOWER3-PHASE, 1800 RPM**
*Insert code 84 for 120 VAC 60Hz, code 80 for 240 VAC, code 81 for 24 VAC 50/60 Hz**Check full load amp rating on motor nameplate to ensure proper overload protectionNote - for additional auxiliary contacts add suffix 10 for 1 N.O., 20 for 2 N.O., 01 for 1 N.C., 02 for 2 N.C., 11 for 1 N.O. & 1 N.C.Example: A50N2S-84A-20 Open frame style, 10 HP, 120 VAC coil, 2 N.O. auxiliary contacts
ABB 3 PHASE MOTOR STARTERA SERIES
All units ship with a NO and NC contacts.Additional contacts can be added in the field.
Incoming LinesL1
L1 L2Disconnect
FuseDisconnect Breaker
1
X1
L1 L2 L3
T1M
OL
OL
T2 T3
T1 T2
MOTOR
T3
X2
3 5 1
External ControlSupply Standard 120 VAC
CX1
2-1 1-1
3-4 3-4
3-2 3-2
3-13-7
3-6
3-3
1-2 2-2
CX23 5
98
JUM
PE
R
97
OL9695
OLM
Remote ContactCustomer
*
15
A1 A2
14
1 2
2 4 6
2 4 6
Non-reversing, single phaseAF09 - AF110, AFN00 - AFN2
WIRING
NEW!
687
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
C D
TEC12, TEC18 Starters TEC25 StarterA 4.72" (11.98 cm) 5.31" (13.48 cm)
B 5.51" (18.99 cm) 6.1" (15.49 cm)
C 6.54" (16.61 cm) 7.28" (18.49 cm)
D 5.9" (14.98 cm) 6.5" (16.51 cm)
E 3.46" (8.78 cm) 3.98" (10.10 cm)
A
BE
DESCRIPTION
TEC Compact Starters are compact 3 phase motor starters .They have an enameled copper wire coil and have finger-safe contacts .These starters are UL 508SB rated . There is an external window indicator that shows contact wear .
FEATURES
• Compact design• cULus, CE, and UL508 approved• Available with reset or start stop• NEMA 4X enclosed• Single or three phase• Class 10 overloads
DIMENSIONS
3 PHASE MOTOR STARTERSTEC COMPACT STARTERS
TEC18-AKSS3-18A
SPECIFICATIONS
HORSE POWER - 3PHASE
Part Number 200V 230V 480V 600VCoil
VoltageEnclosure
NEMA RatingControl Type/
VersionOverload Amp
RangeWeight lbs (kg)
TEC12-A4XR-8A 2 2.5 5 7.5 120V 4X Reset only 5.5 - 8A 2.3 (1.04)
TEC12-G4XR-8A 2 2.5 5 7.5 24V 4X Reset only 5.5 - 8A 2.3 (1.04)
TEC12-AKSS3-8A 2 2.5 5 7.5 120V 4X Start/stop 5.5 - 8A 2.3 (1.04)
TEC12-GKSS3-8A 2 2.5 5 7.5 24V 4X Start/stop 5.5 - 8A 2.3 (1.04)
TEC12-A4XR-13A 3 3 7.5 10 120V 4X Reset only 9 - 13A 2.3 (1.04)
TEC12-G4XR-13A 3 3 7.5 10 24V 4X Reset only 9 - 13A 2.3 (1.04)
TEC12-AKSS3-13A 3 3 7.5 10 120V 4X Start/stop 9 - 13A 2.3 (1.04)
TEC12-GKSS3-13A 3 3 7.5 10 24V 4X Start/stop 9 - 13A 2.3 (1.04)
TEC18-A4XR-18A 5 5 10 15 120V 4X Reset only 7 - 10A 2.3 (1.04)
TEC18-G4XR-18A 5 5 10 15 24V 4X Reset only 7 - 10A 2.3 (1.04)
TEC18-AKSS3-18A 5 5 10 15 120V 4X Start/stop 7 - 10A 2.3 (1.04)
TEC18-GKSS3-18A 5 5 10 15 24V 4X Start/stop 7 - 10A 2.3 (1.04)
TEC25-A4XR-25A 5 7.5 15 20 120V 4X Reset only 17- 25A 2.7 (1.22)
TEC25-G4XR-25A 5 7.5 15 20 24V 4X Reset only 17- 25A 2.7 (1.22)
TEC25-AKSS3-25A 5 7.5 15 20 120V 4X Start/stop 17- 25A 2.7 (1.22)
TEC25-GKSS3-25A 5 7.5 15 20 24V 4X Start/stop 17- 25A 2.7 (1.22)
Other options and models available from manufacturer.
NEW!MOTOR CONTROLS
688
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
ORDERING INFORMATION
MODEL DESCRIPTIONTEC12-A4XR-8A Compact starter, 3 phase, 120 VAC, with reset and overload,5.5 to 8 AmpsTEC12-G4XR-8A Compact starter, 3 phase, 24 VAC, with reset and overload, 5.5 to 8 AmpsTEC12-AKSS3-8A Compact starter, 3 phase, 120 VAC, start/stop and overload, 5.5 to 8 AmpsTEC12-GKSS3-8A Compact starter, 3 phase, 24 VAC, start/stop and overload, 5.5 to 8 AmpsTEC12-A4XR-13A Compact starter, 3 phase, 120 VAC, with reset and overload, 9 to 13 AmpsTEC12-G4XR-13A Compact starter, 3 phase, 24 VAC, with reset and overload, 9 to 13 AmpsTEC12-AKSS3-13A Compact starter, 3 phase, 120 VAC, start/stop and overload, 9 to 13 AmpsTEC12-GKSS3-13A Compact starter, 3 phase, 24 VAC, start/stop and overload, 9 to 13 AmpsTEC18-A4XR-18A Compact starter, 3 phase, 120 VAC, with reset and overload, 12 to 18 AmpsTEC18-G4XR-18A Compact starter, 3 phase, 24 VAC, with reset and overload, 12 to 18 AmpsTEC18-AKSS3-18A Compact starter, 3 phase, 120 VAC, start/stop and overload, 12 to 18 AmpsTEC18-GKSS3-18A Compact starter, 3 phase, 24 VAC, start/stop and overload, 12 to 18 AmpsTEC25-A4XR-25A Compact starter, 3 phase, 120 VAC, with reset and overload, 17 to 25 AmpsTEC25-G4XR-25A Compact starter, 3 phase, 24 VAC, with reset and overload, 17 to 25 AmpsTEC25-AKSS3-25A Compact starter, 3 phase, 120 VAC, start/stop and overload, 17 to 25 AmpsTEC25-GKSS3-25A Compact starter, 3 phase, 24 VAC, start/stop and overload, 17 to 25 Amps
ACCESSORIES EEC0.63-1A Overload relay TEC Series/0.63-1 AmpsEEC1-1.6A Overload relay TEC Series/1-1.6 AmpsEEC1.6-2.5A Overload relay TEC Series/1.6-2.5 AmpsEEC2.5-4A Overload relay TEC Series/2.5-4 AmpsEEC4-6A Overload relay TEC Series/4-6 AmpsEEC5.5-8A Overload relay TEC Series/5.5-8 AmpsEEC7-10A Overload relay TEC Series/7-10 AmpsEEC9-13A Overload relay TEC Series/9-13 AmpsEEC12-18A Overload relay TEC Series/12-18 AmpsEEC17-25A Overload relay TEC Series/17-25 Amps
3 PHASE MOTOR STARTERSTEC COMPACT STARTERS
L1
13M
L1(X1)
14 A1 A2 95 96
(A) (B)
17 18
T1
L1
L2
M
OL
OL RESET
STOP L2(X2)
T2
L2
T3
MTR
M
START
THREE-PHASE** L2 on control circuit should be connected to neutral for 120V control voltage. Dashed lines indicate field connection.
START-STOP PUSHBUTTONS Series TEC…KSS3…*
L3
L1
T1
L1
L2
M13
14Aux. NO
OL
L2
T2
MTR
SINGLE-PHASE*
13M
L1(X1)
14 A1 A2 95 96
(A) (B)
17 18
OL RESET
STOP L2(X2)
M
START
REMOTE START-STOP PUSHBUTTONS Series TEC…4XR… (Reset only)*
WIRING
NEW!
689
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
Supply Voltage 600V MAXEnclosure Rating NEMA 3R/12Auxiliary Contacts (optional)
Maximum number allowed: 2NO + 1NC
Meets ARRA or BAA YesDimensions, Including Handle EOT16 & EOT32 6 .36"H x 3 .94"W x 4 .55"D
(16 .2 x 10 x 11 .6 cm) EOT45 7 .87"H x 5 .75"W x 5 .43"D
(19 .8 x 14 .6 x 18 .8 cm) EOT63 11 .81"H x 8 .27"W x 7 .12"D
(30 x 21 x 181 cm)Approvals UL Listed E63822, IEC947-3, UL 508Note: Only 1 additional pole per switch allowed
DESCRIPTIONThe EOT Series of enclosed manual motor controllers are rotary operated, 3 pole, 600V Hp rated switches, housed in thermoplastic/polycarbonate enclosures suitable for wet and corrosive environments . These NEMA 3R/12 models are equipped with selector style handles . They are compact in size have touch safe operation . cUL/IEC-47-3 approvals and UL508 listed .
FEATURES• Suitable as motor disconnect• Horsepower rated• Touch safe construction• Positive operation• Clear position indication• Self lifting tunnel terminals• Extremely compact size• Accessories include 4th Power Pole & Snap-on auxiliary
contacts• OSHA Lock Out/Tag Out
ENCLOSED NON-FUSED DISCONNECT SWITCHABB EOT SERIES
Selector switch style
EOT products are properly installed on the load side of abranch circuit protective device and are suitable for use asmotor disconnects as illustrated above.
Disconnect means
Short Circuit protective device
Controller
Overload protection
EOT Motor disconnect
WIRING
ORDERING INFORMATION
MODEL DESCRIPTIONEOT16U3P3-S Black selector handle; 16 Amp ratingEOT16U3P3-1S Black selector handle; 16 Amp rating;
1 NO auxiliary contactEOT16U3P3-S1 Red/Yellow selector handle; 16 Amp ratingEOT16U3P3-1S1 Red/Yellow selector handle; 16 Amp rating;
1 NO auxiliary contactEOT32U3P3-S Black selector handle; 40 Amp ratingEOT32U3P3-1S Black selector handle; 40 Amp rating;
1 NO auxiliary contactEOT32U3P3-S1 Red/Yellow selector handle; 40 Amp ratingEOT32U3P3-1S1 Red/Yellow selector handle; 40 Amp rating;
1 NO auxiliary contactEOT45U3P3-S Black selector handle; 60 Amp ratingEOT45U3P3-1S Black selector handle; 60 Amp rating;
1 NO auxiliarycontactEOT45U3P3-S1 Red/Yellow selector handle; 60 Amp ratingEOT45U3P3-1S1 Red/Yellow selector handle; 60 Amp rating;
1 NO auxiliary contactEOT63U3P3-P Black pistol handle; 80 Amp ratingEOT63U3P3-1P Black pistol handle; 80 Amp rating;
1 NO auxiliary contactEOT63U3P3-P1 Red/Yellow pistol handle; 80 Amp ratingEOT63U3P3-1P1 Red/Yellow pistol handle; 80 Amp rating;
1 NO auxiliary contact
ACCESSORIESOA1G01 Auxiliary contact NC, mounts on left side of switch onlyOA1G10 Auxiliary contact, NO mounts on right side of switch onlyOTPL40FP 4th Pole, late-break/early-make function (eOT16 & eOT32)OTPL80FP 4th Pole, late-break/early-make function (eOT45 & eOT63)OTPS40FP 4th Pole (EOT16 & eOT32)OTPS80FP 4th Pole (EOT45 & eOT63)
HORSEPOWER RATINGSModel Series eOT16 eOT32 eOT45 eOT63Three Phase Max HP200-208V 3 10 15 20240V 6 10 15 20480V 10 20 30 40600V 10 25 30 40Single Phase Max HP120V 1 2 2 2240V 2 5 7.5 10
SPECIFICATIONS
NEW!MOTOR CONTROLS
690
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
BREAKER COMBINATION MOTOR STARTERSBCXLS SERIES
DESCRIPTION
Breaker combnation motor starters are UL508 . They include 600 Volt internatinally accepted industrial control breakers with instantaneous and thermal trip . They all have door handle safety interlocks and pilot lights . Magnetic starters with percision and consisten overload protection and different single phasing protection .
FEATURES
• Breakers with instantaneous and thermal trip• NEMA 1 or NEMA 12/4 enclosure• Space and drilling for fused control circuit transformer• HOA switch• Pilot light • Door safety interlocks• 24V or 120V coil voltage• UL File #E90628
BCXLS11K-1G-0N-M01-H0A-PL
FUSIBLE CONTROL TRANSFORMERSModel Primary Volts Secondary Volts Continuous VA Contactors to use with Height Width Depth
B050MBT713RK 208V, 230V, 460V 115V, 24V 50VA LS07,4,7,17,27,37, LS05,4K,7K,11K,18K 3.25" (83 mm) 3.0" (76 mm) 3.93" (100 mm)B100MBT713RK 208V, 230V, 460V 115V, 24V 100VA LS47,57,77,87,107 ,LS22K,30K,37K,45K, LS55K 3.62"(92 mm) 3.75" (95 mm) 4.55" (76 mm) B150MBT713RK 208V, 230V, 460V 115V, 24V 150VA LS177, LS75K LS90K(3P) 4.37" (111 mm) 3.75" (95 mm) 4.55" (76 mm) B200MBT713RK 208V, 230V, 460V 115V, 24V 200VA LS247 LS110K, 132K, 160K 4.5" (114 mm) 4.5" (114 mm) 5.18" (132 mm)B250MBT713RK 208V, 230V, 460V 115V, 24V 250VA LS220K, 280K, 375K 5.25" (133 mm) 4.5" (114 mm) 5.18" (132 mm)B300MBT713RK 208V, 230V, 460V 115V, 24V 300VA LS450K 5.12" (130 mm) 5.25" (133 mm) 6.12" (155 mm)B350MBT713RK 208V, 230V, 460V 115V, 24V 350VA 5.37" (137 mm) 5.25" (133 mm) 6.12" (155 mm)
BREAKER COMBINATION
L1
H1
T1
L2
H4
L3
T3
14
13M
M
A1
A1 X2
95 96
L2
A2
OL
Aux. NO
OL
T2
MTR
RA1 A2
X2
L2
X1
L1
ON PL
OFF PL
PILOT LIGHTSTRANSFORMER
CONTROL CIRCUIT
21 22M
H3 H2
FU
X1 X2
G
H1(L1) H4(L2)
X2
L2
X1
L1 95 96A1 A2
13 14
OFFHAND AUTO
REMOTE SWITCH
23 24 1
OL
M
2
X1
L1START
AUX
STOP
X2
L295 96A1 A221
13 14
13 14
22OL
M
X1
L1OFF ON
X2
L295 96A1 A2
13 14
OL
M
WIRING
NEW!
691
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
BREAKER COMBINATION MOTOR STARTERSBCXLS SERIES
ORDERING INFORMATION/SPECIFICATIONS
Part Number HP Voltage Coil Voltage
Enclosure NEMA Rating
Coil Inrush
Coil Holding Current
Overload Range
Breaker Rating
Dimensions in (lb)
Weight lb (kg)
BCXLS7K-1G-O-M01-HOA-PL
5 200/23024 VAC
1
45 VA 6 VA 14.5-18 Amps 30A 16" x 12" x 8"
(40.6 x 30.5 x 20.3) 31 (14.1)BCXLS7K-1G-O-M4-HOA-PL 12/4BCXLS7K-1A-O-M01-HOA-PL
120 VAC1
BCXLS7K-1A-O-M4-HOA-PL 12/4BCXLS7K-2G-O-M01-HOA-PL
10 46024 VAC
1
45 VA 6 VA 14.5-18 Amps 30A 16" x 12" x 8"
(40.6 x 30.5 x 20.3) 31 (14.1)BCXLS7K-2G-O-M4-HOA-PL 12/4BCXLS7K-2A-O-M01-HOA-PL
120 VAC1
BCXLS7K-2A-O-M4-HOA-PL 12/4BCXLS11K-1G-ON-M01-HOA-PL
7.5 23024 VAC
1
88 VA 9 VA 21-26 Amps 50A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 32 (14.5)
BCXLS11K-1G-ON-M4-HOA-PL 12/4BCXLS11K-1A-ON-M01-HOA-PL
120 VAC1
BCXLS11K-1A-ON-M4-HOA-PL 12/4BCXLS11K-2G-ON-M01-HOA-PL
15 46024 VAC
1
88 VA 9 VA 21-26 Amps 50A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 32 (14.5)
BCXLS11K-2G-ON-M4-HOA-PL 12/4BCXLS11K-2A-ON-M01-HOA-PL
120 VAC1
BCXLS11K-2A-ON-M4-HOA-PL 12/4BCXLS15K-1G-Q-M01-HOA-PL
10 20024 VAC
1
88 VA 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15)
BCXLS15K-1G-Q-M4-HOA-PL 12/4BCXLS15K-1A-Q-M01-HOA-PL
120 VAC1
BCXLS15K-1A-Q-M4-HOA-PL 12/4BCXLS15K-2G-Q-M01-HOA-PL
10 23024 VAC
1
88 VA 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15)
BCXLS15K-2G-Q-M4-HOA-PL 12/4BCXLS15K-2A-Q-M01-HOA-PL
120 VAC1
BCXLS15K-2A-Q-M4-HOA-PL 12/4BCXLS15K-3G-Q-M01-HOA-PL
20 46024 VAC
1
88 VA 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15)
BCXLS15K-3G-Q-M4-HOA-PL 12/4BCXLS15K-3A-Q-M01-HOA-PL
120 VAC1
BCXLS15K-3A-Q-M4-HOA-PL 12/4BCXLS22K-1G-RN-M01-HOA-PL
15 200/23024 VAC
1
191 VA 17 VA 54-65 Amps 125A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 45 (20.4)
BCXLS22K-1G-RN-M4-HOA-PL 12/4BCXLS22K-1A-RN-M01-HOA-PL
120 VAC1
BCXLS22K-1A-RN-M4-HOA-PL 12/4BCXLS22K-2G-QN-M01-HOA-PL
30 46024 VAC
1
191 VA 17 VA 42-55 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 45 (20.4)
BCXLS22K-2G-QN-M4-HOA-PL 12/4BCXLS22K-2A-QN-M01-HOA-PL
120 VAC1
BCXLS22K-2A-QN-M4-HOA-PL 12/4BCXLS37K-1G-SN-M01-HOA-PL
20/25 200/23024 VAC
1
191 VA 17 VA 64-82 Amps 150A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 47 (21.3)
BCXLS37K-1G-SN-M4-HOA-PL 12/4BCXLS37K-1A-SN-M01-HOA-PL
120 VAC1
BCXLS37K-1A-SN-M4-HOA-PL 12/4BCXLS37K-2G-SN-M01-HOA-PL
50 46024 VAC
1
191 VA 17 VA 64-82 Amps 150A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 47 (21.3)
BCXLS37K-2G-SN-M4-HOA-PL 12/4BCXLS37K-2A-SN-M01-HOA-PL
120 VAC1
BCXLS37K-2A-SN-M4-HOA-PL 12/4BCXLS45K-1G-TM-M01-HOA-PL
25/30 200/23024 VAC
1
191 VA 17 VA 78-97 Amps 150A 24" x 20" x 8" (61 x 50.8 x 20.3) 61 (27.7)
BCXLS45K-1G-TM-M4-HOA-PL 12/4BCXLS45K-1A-TM-M01-HOA-PL
120 VAC1
BCXLS45K-1A-TM-M4-HOA-PL 12/4BCXLS45K-2G-TM-M01-HOA-PL
60 46024 VAC
1
191 VA 17 VA 78-97 Amps 150A 24" x 20" x 8" (61 x 50.8 x 20.3) 61 (27.7)
BCXLS45K-2G-TM-M4-HOA-PL 12/4BCXLS45K-2A-TM-M01-HOA-PL
120 VAC1
BCXLS45K-2A-TM-M4-HOA-PL 12/4BCXLS55K-1G-TN-M01-HOA-PL
40 23024 VAC
1
191 VA 17 VA 90-110 Amps 175A 24" x 20" x 8" (61 x 50.8 x 20.3) 63 (28.6)
BCXLS55K-1G-TN-M4-HOA-PL 12/4BCXLS55K-1A-TN-M01-HOA-PL
120 VAC1
BCXLS55K-1A-TN-M4-HOA-PL 12/4BCXLS55K-2G-TN-M01-HOA-PL
75 460 24 VAC
1
191 VA 17 VA 90-110 Amps 175A 24" x 20" x 8" (61 x 50.8 x 20.3) 63 (28.6)
BCXLS55K-2G-TN-M4-HOA-PL 12/4BCXLS55K-2A-TN-M01-HOA-PL 1BCXLS55K-2A-TN-M4-HOA-PL 12/4BCXLS75K-1G-TT-M01-HOA-PL
40/50 200/23024 VAC
1
400 VA 32 VA 140-190 Amps 225A 30" x 24" x 8"
(76.2 x 61 x 20.3) 97 (44)BCXLS75K-1G-TT-M4-HOA-PL 12/4BCXLS75K-1A-TT-M01-HOA-PL
120 VAC1
BCXLS75K-1A-TT-M4-HOA-PL 12/4BCXLS75K-2G-TT-M01-HOA-PL
100 46024 VAC
1
400 VA 32 VA 140-190 Amps 225A 30" x 24" x 8"
(76.2 x 61 x 20.3) 97 (44)BCXLS75K-2G-TT-M4-HOA-PL 12/4BCXLS75K-2A-TT-M01-HOA-PL
120 VAC1
BCXLS75K-2A-TT-M4-HOA-PL 12/4
NEW!MOTOR CONTROLS
692
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
FUSIBLE AND NON-FUSIBLE MOTOR STARTERSFCXLS, NFCXLS SERIES
DESCRIPTION
Fusible and Non-Fusible combination controls for your motor. These have UL/CSA manual motor disconnects with door safety interlocks. Industrial controls disconnects are load make, load break, UL listed for motor load switching duty. Starter and overload relay complete with precision ambient compensated heaters and differential single phasing protection.
FEATURES
• NEMA 1 or NEMA 12/4 enclosure• Space and drilling for fused control circuit transformer• HOA switch• Pilot light • Door safety interlocks• 24V or 120V coil voltage• UL File #E90628 FCXLS7K-2A-0-M4-HOA-PL
RA1 A2
X2
L2
X1
L1
ON PL
OFF PL
PILOT LIGHTSTRANSFORMER
CONTROL CIRCUIT
21 22M
H3 H2
FU
X1 X2
G
X2
L2
X1
L1 95 96A1 A2
13 14
OFFHAND AUTO
REMOTE SWITCH
23 24 1
OL
M
H1(L1) H4(L2)
2
M
X1
L1START
AUX
STOP
X2
L295 96A1 A221
13 14
13 14
22OL
X1
L1OFF ON
X2
L295 96A1 A2
13 14
OL
M
FUSIBLE COMBINATION
M
A1
A1 X2
95 96
L2
A2
OL
L1
H1
T1
L2
H4
L3
T3
M
OL
T2
MTR
WIRING
FUSIBLE CONTROL TRANSFORMERSModel Primary Volts Secondary Volts Continuous VA Contactors to use with Height Width Depth
B050MBT713RK
208V, 230V, 460V 115V, 24V
50VA LS07,4,7,17,27,37, LS05,4K,7K,11K,18K 3.25" (83mm) 3.0" (76mm) 3.93" (100mm
B100MBT713RK 100VA LS47,57,77,87,107 ,LS22K,30K,37K,45K, LS55K 3.62"(92mm) 3.75" (95mm) 4.55" (76mm)
B150MBT713RK 150VA LS177, LS75K LS90K(3P) 4.37" (111mm) 3.75" (95mm) 4.55" (76mm)
B200MBT713RK 200VA LS247 LS110K, 132K, 160K 4.5" (114mm) 4.5" (114mm) 5.18" (132mm)
B250MBT713RK 250VA LS220K, 280K, 375K 5.25" (133mm) 4.5" (114mm) 5.18" (132mm)
B300MBT713RK 300VA LS450K 5.12" (130mm) 5.25" (133mm) 6.12" (155mm)
B350MBT713RK 350VA 5.37" (137mm) 5.25" (133mm) 6.12" (155mm)
NEW!
693
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
FUSIBLE AND NON-FUSIBLE MOTOR STARTERSFCXLS, NFCXLS SERIES
ORDERING INFORMATION - FCXLS
Part Number HP Voltage Coil
VoltageEnclosure
NEMA RatingCoil
InrushCoil Holding
CurrentOverload
RangeFuse Block
RatingDimensions
in (cm)Weight lb (kg)
FCXLS7K-1G-O-M01-HOA-PL
5 200/23024 VAC 1
45 VA 6 VA 14.5-18 30A 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.16)FCXLS7K-1G-O-M4-HOA-PL 12/4
FCXLS7K-1A-O-M01-HOA-PL 120 VAC 1FCXLS7K-1A-O-M4-HOA-PL 12/4FCXLS7K-2G-O-M01-HOA-PL
10 46024 VAC
1
45 VA 6 VA 14.5-18 Amps 30A 12" x 10" x 6"
(30.5 x 25.4 x 15.2) 18 (8.16)FCXLS7K-2G-O-M4-HOA-PL 12/4FCXLS7K-2A-O-M01-HOA-PL 120 VAC 1FCXLS7K-2A-O-M4-HOA-PL 12/4FCXLS11K-1G-ON-M01-HOA-PL
7.5 23024 VAC 1
88 VA 9 VA 21-26 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 18 (8.16)FCXLS11K-1G-ON-M4-HOA-PL 12/4
FCXLS11K-1A-ON-M01-HOA-PL 120 VAC 1FCXLS11K-1A-ON-M4-HOA-PL 12/4FCXLS11K-2G-ON-M01-HOA-PL
15 46024 VAC 1
88 VA 9 VA 21-26 Amps 30A 12" x 10" x 6" (30.5 x 25.4 x 15.2)
18 (8.16)18 (8.16)18 (8.16)18 (8.16)
FCXLS11K-2G-ON-M4-HOA-PL 12/4FCXLS11K-2A-ON-M01-HOA-PL 120 VAC 1FCXLS11K-2A-ON-M4-HOA-PL 12/4FCXLS15K-1G-Q-M01-HOA-PL
10 20024 VAC 1
88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)FCXLS15K-1G-Q-M4-HOA-PL 12/4
FCXLS15K-1A-Q-M01-HOA-PL 120 VAC 1FCXLS15K-1A-Q-M4-HOA-PL 12/4FCXLS15K-2G-Q-M01-HOA-PL
10 23024 VAC 1
88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)FCXLS15K-2G-Q-M4-HOA-PL 12/4
FCXLS15K-2A-Q-M01-HOA-PL 120 VAC 1FCXLS15K-2A-Q-M4-HOA-PL 12/4FCXLS15K-3G-Q-M01-HOA-PL
20 46024 VAC 1
88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)
FCXLS15K-3G-Q-M4-HOA-PL 12/4FCXLS15K-3A-Q-M01-HOA-PL 120 VAC 1FCXLS15K-3A-Q-M4-HOA-PL 12/4FCXLS22K-1G-RN-M01-HOA-PL
15 200/23024 VAC 1
191 VA 17 VA 54-65 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 41 (18.6)FCXLS22K-1G-RN-M4-HOA-PL 12/4
FCXLS22K-1A-RN-M01-HOA-PL 120 VAC 1FCXLS22K-1A-RN-M4-HOA-PL 12/4FCXLS22K-2G-QN-M01-HOA-PL
30 46024 VAC 1
191 VA 17 VA 42-55 Amps 60A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 41 (18.6)FCXLS22K-2G-QN-M4-HOA-PL 12/4
FCXLS22K-2A-QN-M01-HOA-PL 120 VAC 1FCXLS22K-2A-QN-M4-HOA-PL 12/4FCXLS37K-1G-SN-M01-HOA-PL
20/25 200/23024 VAC 1
191 VA 17 VA 64-82 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 42 (19.1)FCXLS37K-1G-SN-M4-HOA-PL 12/4
FCXLS37K-1A-SN-M01-HOA-PL 120 VAC 1FCXLS37K-1A-SN-M4-HOA-PL 12/4FCXLS37K-2G-SN-M01-HOA-PL
50 46024 VAC 1
191 VA 17 VA 64-82 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 42 (19.1)FCXLS37K-2G-SN-M4-HOA-PL 12/4
FCXLS37K-2A-SN-M01-HOA-PL 120 VAC 1FCXLS37K-2A-SN-M4-HOA-PL 12/4FCXLS45K-1G-TM-M01-HOA-PL
25/30 200/23024 VAC 1
191 VA 17 VA 78-97 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 44 (20)FCXLS45K-1G-TM-M4-HOA-PL 12/4
FCXLS45K-1A-TM-M01-HOA-PL 120 VAC 1FCXLS45K-1A-TM-M4-HOA-PL 12/4FCXLS45K-2G-TM-M01-HOA-PL
60 46024 VAC 1
191 VA 17 VA 78-97 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 44 (20)FCXLS45K-2G-TM-M4-HOA-PL 12/4
FCXLS45K-2A-TM-M01-HOA-PL 120 VAC 1FCXLS45K-2A-TM-M4-HOA-PL 12/4FCXLS55K-1G-TN-M01-HOA-PL
40 23024 VAC 1
191 VA 17 VA 90-110 Amps 200A 30" x 24" x 8" (76.2 x 61 x 20.3) 88 (40)FCXLS55K-1G-TN-M4-HOA-PL 12/4
FCXLS55K-1A-TN-M01-HOA-PL 120 VAC 1FCXLS55K-1A-TN-M4-HOA-PL 12/4FCXLS55K-2G-TN-M01-HOA-PL
75 46024 VAC 1
191 VA 17 VA 90-110 Amps 200A 30" x 24" x 8" (76.2 x 61 x 20.3) 88 (40)FCXLS55K-2G-TN-M4-HOA-PL 12/4
FCXLS55K-2A-TN-M01-HOA-PL 120 VAC 1FCXLS55K-2A-TN-M4-HOA-PL 12/4FCXLS75K-1G-TT-M01-HOA-PL
40/50 200/23024 VAC 1
400 VA 32 VA 140-190 Amps 200A 36" x 24" x 10"
(91.4 x 61 x 25.4) 124 (56.2)FCXLS75K-1G-TT-M4-HOA-PL 12/4FCXLS75K-1A-TT-M01-HOA-PL 120 VAC 1FCXLS75K-1A-TT-M4-HOA-PL 12/4FCXLS75K-2G-TT-M01-HOA-PL
100 46024 VAC 1
400 VA 32 VA 140-190 Amps 200A 36" x 24" x 10"
(91.4 x 61 x 25.4) 124 (56.2)FCXLS75K-2G-TT-M4-HOA-PL 12/4FCXLS75K-2A-TT-M01-HOA-PL 120 VAC 1FCXLS75K-2A-TT-M4-HOA-PL 12/4
NEW!MOTOR CONTROLS
694
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
ORDERING INFORMATION - NFCXLS
Part Number HP Voltage Coil Voltage
Enclosure NEMA Rating
Coil Inrush
Coil Holding Current
Overload Range
Dimensions in (cm)
Weight lb (kg)
NFCXLS7K-1G-O-M01-HOA-PL
5 200/23024 VAC
1
45 VA 6 VA 14.5-18 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7)
NFCXLS7K-1G-O-M4-HOA-PL 12/4NFCXLS7K-1A-O-M01-HOA-PL
120 VAC1
NFCXLS7K-1A-O-M4-HOA-PL 12/4NFCXLS7K-2G-O-M01-HOA-PL
10 46024 VAC
1
45 VA 6 VA 14.5-18 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7)
NFCXLS7K-2G-O-M4-HOA-PL 12/4NFCXLS7K-2A-O-M01-HOA-PL
120 VAC1
NFCXLS7K-2A-O-M4-HOA-PL 12/4NFCXLS11K-1G-ON-M01-HOA-PL
7.5 23024 VAC
1
88 VA 9 VA 21-26 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7)NFCXLS11K-1G-ON-M4-HOA-PL 12/4NFCXLS11K-1A-ON-M01-HOA-PL
120 VAC1
NFCXLS11K-1A-ON-M4-HOA-PL 12/4NFCXLS11K-2G-ON-M01-HOA-PL
15 46024 VAC
1
88 VA 9 VA 21-26 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7)NFCXLS11K-2G-ON-M4-HOA-PL 12/4NFCXLS11K-2A-ON-M01-HOA-PL
120 VAC1
NFCXLS11K-2A-ON-M4-HOA-PL 12/4NFCXLS15K-1G-Q-M01-HOA-PL
10 20024 VAC
1
88 VA 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2)NFCXLS15K-1G-Q-M4-HOA-PL 12/4NFCXLS15K-1A-Q-M01-HOA-PL
120 VAC1
NFCXLS15K-1A-Q-M4-HOA-PL 12/4NFCXLS15K-2G-Q-M01-HOA-PL
10 23024 VAC
1
88 VA 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2)NFCXLS15K-2G-Q-M4-HOA-PL 12/4NFCXLS15K-2A-Q-M01-HOA-PL
120 VAC1
NFCXLS15K-2A-Q-M4-HOA-PL 12/4NFCXLS15K-3G-Q-M01-HOA-PL
20 46024 VAC
1
88 VA 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2)NFCXLS15K-3G-Q-M4-HOA-PL 12/4NFCXLS15K-3A-Q-M01-HOA-PL
120 VAC1
NFCXLS15K-3A-Q-M4-HOA-PL 12/4NFCXLS22K-1G-RN-M01-HOA-PL
15 200/23024 VAC
1
191 VA 17 VA 54-65 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)NFCXLS22K-1G-RN-M4-HOA-PL 12/4NFCXLS22K-1A-RN-M01-HOA-PL
120 VAC1
NFCXLS22K-1A-RN-M4-HOA-PL 12/4NFCXLS22K-2G-QN-M01-HOA-PL
30 46024 VAC
1
191 VA 17 VA 42-55 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)NFCXLS22K-2G-QN-M4-HOA-PL 12/4NFCXLS22K-2A-QN-M01-HOA-PL
120 VAC1
NFCXLS22K-2A-QN-M4-HOA-PL 12/4NFCXLS37K-1G-SN-M01-HOA-PL
20/25 200/23024 VAC
1
191 VA 17 VA 64-82 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 28 (12.7)NFCXLS37K-1G-SN-M4-HOA-PL 12/4NFCXLS37K-1A-SN-M01-HOA-PL
120 VAC1
NFCXLS37K-1A-SN-M4-HOA-PL 12/4NFCXLS37K-2G-SN-M01-HOA-PL
50 46024 VAC
1
191 VA 17 VA 64-82 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 28 (12.7)NFCXLS37K-2G-SN-M4-HOA-PL 12/4NFCXLS37K-2A-SN-M01-HOA-PL
120 VAC1
NFCXLS37K-2A-SN-M4-HOA-PL 12/4NFCXLS45K-1G-TM-M01-HOA-PL
25/30 200/230 24 VAC120 VAC
1
191 VA 17 VA 78-97 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 38 (17.2)NFCXLS45K-1G-TM-M4-HOA-PL 12/4NFCXLS45K-1A-TM-M01-HOA-PL 1NFCXLS45K-1A-TM-M4-HOA-PL 12/4NFCXLS45K-2G-TM-M01-HOA-PL
60 46024 VAC
1
191 VA 17 VA 78-97 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 38 (17.2)NFCXLS45K-2G-TM-M4-HOA-PL 12/4NFCXLS45K-2A-TM-M01-HOA-PL
120 VAC1
NFCXLS45K-2A-TM-M4-HOA-PL 12/4NFCXLS55K-1G-TN-M01-HOA-PL
40 23024 VAC
1
191 VA 17 VA 90-110 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 40 (18.1)
NFCXLS55K-1G-TN-M4-HOA-PL 12/4NFCXLS55K-1A-TN-M01-HOA-PL
120 VAC1
NFCXLS55K-1A-TN-M4-HOA-PL 12/4NFCXLS55K-2G-TN-M01-HOA-PL
75 46024 VAC
1
191 VA 17 VA 90-110 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 40 (18.1)
NFCXLS55K-2G-TN-M4-HOA-PL 12/4NFCXLS55K-2A-TN-M01-HOA-PL
120 VAC1
NFCXLS55K-2A-TN-M4-HOA-PL 12/4NFCXLS75K-1G-TT-M01-HOA-PL
40/50 200/23024 VAC
1
400 VA 32 VA 140-190 Amps 24" x 20" x 8" (60.1 x 50.8 x 20.3) 65 (29.4)
NFCXLS75K-1G-TT-M4-HOA-PL 12/4NFCXLS75K-1A-TT-M01-HOA-PL
120 VAC1
NFCXLS75K-1A-TT-M4-HOA-PL 12/4NFCXLS75K-2G-TT-M01-HOA-PL
100 46024 VAC
1
400 VA 32 VA 140-190 Amps 24" x 20" x 8" (60.1 x 50.8 x 20.3) 65 (29.4)
NFCXLS75K-2G-TT-M4-HOA-PL 12/4NFCXLS75K-2A-TT-M01-HOA-PL
120 VAC1
NFCXLS75K-2A-TT-M4-HOA-PL 12/4
FUSIBLE AND NON-FUSIBLE MOTOR STARTERSFCXLS, NFCXLS SERIES
NEW!
695
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
Supply Voltage Model specific, 3 phase, 60 Hz, 380-480 VAC or 200-240 VAC
Motor Rating 0 .75 to 250 HpFrequency Range 0-320 HzAcceleration Time 0 .1 - 3000 secondsDeceleration Time 0 .1 - 3000 secondsDigital Input 6 logical, 24 VDC= on, 0 VDC= off,
all configurableAnalog Input 2; 0-010v or 4-20 mA voltage Input impedance 200Ω k Current impedance 250ΩDigital Output Open collector, max . load
48V/ 50 mAAnalog Output 1; 0-10 VDC or 4-20 mA
programmable 500Ω maximum load
Relay Outputs 2; SPDT 8A at 24VDC or 250 VAC 0 .4A at 125 VDC minimum load 10mA at 5 VAC/VDCFilter Type 5% DC choke (Frame D and E
standard; 3% built in) -- Optional for frames A, B, C
Class 2 GMC/ RFIEMC Complies with EN50082-1, -2 EN61800-3Communication Protocol RS485 MODBUS, BACnetOperating Humidity 0 to 90% RH, non-condensingOperating Temperature 14° to 104°F (-10° to 40°C)Approvals UL Listed File E190898, CE, RoHSEco Friendly YesWarranty 3 years
HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD
DESCRIPTION
CORE VFDs are an economical option drive option with easy to set up functionality . The firmware includes special features that make start-up and commissioning of HVAC applications especially easy . The Wizard consists of critical commissioning questions to intuitively guide users through parameter setup process, which covers nearly all your commercial heating, ventilation and air conditioning (HVAC) applications . Additionally, the VFD CORE is rated for constant torque for industrial applications . The CORE VFD line is also available with a bypass option which is also easy to integrate . The by-pass comes with a control transformer, time delay fuses, 3 contactors, primary and secondary fuses . The CORE line of VFDs is a time saver as well as an energy saver .
FEATURES
• Intuitive commissioning• Start-up wizard• Real-time clock• Detachable keypad• PID with sleep control
SPECIFICATIONS
HCRDA005DA1000T
DIMENSIONS AND WEIGHTS
Frame 208/230 VAC 460 VACEnclosure NEMA type
Width in (cm)
Height in (cm)
Depth in (cm)
Weight lb (kg)
A 1.0 - 7.5 HP 1.0 - 10 HP NEMA 1 5.12 (13.0) 9.84 (25.0) 6.69 (17.0) 6.17 (2.8)
B 10 - 15 HP 15 HP NEMA 1 7.48 (19.0) 12.6 (32.0) 7.48 (19.0) 10.14 (4.6)
B 20 HP 20 - 25 HP NEMA 1 7.48 (19.0) 12.6 (32.0) 7.48 (19.0) 12.35 (5.6)
C 25 - 40 HP NEMA 1 9.84 (25.0) 15.75 (40.0) 8.27 (21.0) 23.15 (10.5)
C 30 - 40 HP NEMA 1 9.84 (25.0) 15.75 (40.0) 8.27 (21.0) 19.18 (8.7)
C 50 HP NEMA 1 9.84 (25.0) 15.75 (40.0) 8.27 (21.0) 20.72 (9.4)
D 50 - 60 HP 60 - 75 HP NEMA 1 12.99 (33.0) 27.10 (68.83) 10.83 (27.5) 78.26 (35.5)
D 100 - 125 HP NEMA 1 12.99 (33.0) 27.10 (68.83) 10.83 (27.5) 89.29 (40.5)
E 75 HP NEMA 1 14.57 (37.0) 28.18 (71.58) 11.81 (30.0) 100.75 (45.7)
E 100 HP NEMA 1 14.57 (37.0) 28.18 (71.58) 11.81 (30.0) 101.85 (46.2)
E 125 HP NEMA 1 14.57 (37.0) 28.18 (71.58) 11.81 (30.0) 120.59 (54.7)
NEW!MOTOR CONTROLS
696
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
Frame Sizes A, B, and C
R(L1)
S(L2)
T(L3)
FWD
R(L1)
S(L2)
T(L3)
NFB U(T1)
V(T2)
W(T3)
MOTOR
JUMPER
DC CHOKE(OPTIONAL) BREAKING RESISTOR
(OPTIONAL)
IM3~
REVMI1
FWD/STOPREV/STOP
3-PHASE POWER IS PROVIDED
FUSE/NO FUSE BREAKER
FACTORY SETTING:PNP SOURCE
PRESET SPD 1PRESET SPD 2PRESET SPD3
PRESET SPD 4EXT FAULTFAULT RESET
NANA
MI3MI2
MI4MI5MI6MI7MI8
MULTI-FUNCTIONOUTPUT TERMINALS
RA1
RB1
RC1
RA2
RC2
RA3
RC3
250VAC/6A
30VDC/6A
30VDC/5A
MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A
MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A
30VDC/5ADCM
SCM
S1
DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE
FACTORY SETTING
POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP
DIGITAL SIGNAL COMMON TERMINAL
+10V/20mA
0~10V/0~20mA
0-20mA/0~10V
ANALOG SIGNALCOMMON TERMINAL
3 21
5KΩ
MAIN CIRCUIT (POWER) TERMINALS
CONTROL TERMINALS
SHIELDED LEADS & CABLES
+10V
AVI1
ACI
AVI2 ACM
AFM1
ACM
AFM2ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA
ANALOG SIGNAL COMMON TERMINAL
ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA
OPTION SLOT 1
OPTION SLOT 3
COMMUNICATION EXTENSION CARD
I/O & RELAY EXTENSION CARD8 18 1MODBUS RS-485PIN 1~2, 7, 8: RESERVEDPIN 3, 6: GNDPIN 4: SG-PIN 5: SG+
SG+
SG-
0~+10V
COM
DCM
+24V
RA1 (RELAY OUT 1): RUNRA2 (RELAY OUT 2): FAULTRA3 (RELAY OUT 3): READY
MI: MULTIFUNCTION INPUTAVI: ANALOG VOLTAGE INPUTACI: ANALOG CURRENT INPUT
+24V
Frame Sizes D and E
FWD
U(T1)
V(T2)
W(T3)
MOTOR
IM3~
REVMI1
FWD/STOPREV/STOP
3-PHASE POWER IS PROVIDED
R(L1)
S(L2)
T(L3)
R(L1)
S(L2)
T(L3)
NFB
FUSE/NO FUSE BREAKER
FACTORY SETTING:PNP SOURCE
PRESET SPD 1PRESET SPD 2PRESET SPD 3
PRESET SPD 4EXT FAULTFAULT RESET
NANA
MI3MI2
MI4MI5MI6MI7MI8
MULTI-FUNCTIONOUTPUT TERMINALS
RA1
RB1
RC1
RA2
RC2
RA3
RC3
250VAC/6A
30VDC/6A
30VDC/5A
250VAC/5A
MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A
MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 30VDC/5A
DCM
SCM
S1
DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE
FACTORY SETTING
POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP
DIGITAL SIGNAL COMMON TERMINAL
+10V/20mA
0~10V/0~20mA
0-20mA/0~10V
ANALOG SIGNALCOMMON TERMINAL
3 21
5KΩ
MAIN CIRCUIT (POWER) TERMINALS
CONTROL TERMINALS
SHIELDED LEADS & CABLES
+10V
AVI1
ACI
AVI2 ACM
AFM1
ACM
AFM2ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA
ANALOG SIGNAL COMMON TERMINAL
ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA
OPTION SLOT 1
OPTION SLOT 3
COMMUNICATION EXTENSION CARD
I/O & RELAY EXTENSION CARD8 18 1MODBUS RS-485PIN 1~2, 7, 8: RESERVEDPIN 3, 6: GNDPIN 4: SG-PIN 5: SG+
SG+
SG-
0~+10V
COM
DCM
+24V
+1/DC+ -/DC+
r
s
R
S
FRAME E
RA1 (RELAY OUT 1): RUNRA2 (RELAY OUT 2): FAULTRA3 (RELAY OUT 3): READY
MI: MULTIFUNCTION INPUTAVI: ANALOG VOLTAGE INPUTACI: ANALOG CURRENT INPUT
+24V
Source Mode with internal power (+24 VDC)
M1
M2
M8
+24V
DCM
COM
INTERNAL CIRCUIT
WIRING
HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD
NEW!
697
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
ORDERING INFORMATION
MODEL DESCRIPTIONHCRDA0020A1000T Core VFD 230 V, 2 HP, NEMA 1HCRDA0030A1000T Core VFD 230 V, 3 HP, NEMA 1HCRDA0050A1000T Core VFD 230 V, 5 HP, NEMA 1HCRDA0075A1000T Core VFD 230 V, 7.5 HP, NEMA 1HCRDA0100B1000T Core VFD 230 V, 10 HP, NEMA 1HCRDA0150B1000T Core VFD 230 V, 15 HP, NEMA 1HCRDA0200B1000T Core VFD 230 V, 20 HP, NEMA 1HCRDA0250C1000T Core VFD 230 V, 25 HP, NEMA 1HCRDA0300C1000T Core VFD 230 V, 30 HP, NEMA 1HCRDA0400C1000T Core VFD 230 V, 40 HP, NEMA 1HCRDA0500D1000T Core VFD 230 V, 50 HP, NEMA 1HCRDA0600D1000T Core VFD 230 V, 60 HP, NEMA 1HCRDA0750E1000T Core VFD 230 V, 75 HP, NEMA 1HCRDA1000E1000T Core VFD 230 V, 100 HP, NEMA 1HCRDA1250E1000T Core VFD 230 V, 125 HP, NEMA 1HCRDC0010A1000T Core VFD 460 V, 1 HP, NEMA 1HCRDC0020A1000T Core VFD 460 V, 2 HP, NEMA 1HCRDC0030A1000T Core VFD 460 V, 3 HP, NEMA 1HCRDC0050A1000T Core VFD 460 V, 5 HP, NEMA 1HCRDC0075A1000T Core VFD 460 V, 7.5 HP, NEMA 1HCRDC0100A1000T Core VFD 460 V, 10 HP, NEMA 1HCRDC0150B1000T Core VFD 460 V, 15 HP, NEMA 1HCRDC0200B1000T Core VFD 460 V, 20 HP, NEMA 1HCRDC0250B1000T Core VFD 460 V, 25 HP, NEMA 1HCRDC0300C1000T Core VFD 460 V, 30 HP, NEMA 1HCRDC0400C1000T Core VFD 460 V, 40 HP, NEMA 1HCRDC0500C1000T Core VFD 460 V, 50 HP, NEMA 1HCRDC0600D1000T Core VFD 460 V, 60 HP, NEMA 1HCRDC0750D1000T Core VFD 460 V, 75 HP, NEMA 1HCRDC1000D1000T Core VFD 460 V, 100 HP, NEMA 1HCRDC1250D1000T Core VFD 460 V, 125 HP, NEMA 1HCRDA0010A1000T Core VFD 230 V, 1 HP, NEMA 1
HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD
NEW!MOTOR CONTROLS
698
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
Supply Voltage Model specific, 3 phase, 60 Hz, 380-480 VAC or 200-240 VAC
Motor Rating 0 .75 to 250 HpFrequency Range 0-320 HzAcceleration Time 0 .1 - 3000 secondsDeceleration Time 0 .1 - 3000 secondsDigital Inputs 6 logical, 24 VDC = on, 0 VDC = off,
all configurableAnalog Input 2; 0-010V or 4-20 mA voltageInput Impedance 200Ω kCurrent Impedance 250ΩDigital Output Open collector, max . load 48V/ 50
mAAnalog Output 1; 0-10 VDC or 4-20 mA
programmable 500Ω maximum load
Relay Outputs 2; SPDT 8A at 24VDC or 250 VAC 0 .4A at 125 VDC minimum load 10mA at 5 VAC/VDCFilter Type 5% DC choke optional on frames
A, B, and CClass 2 GMC/ RFIEMC Complies with EN50082-1, -2 EN61800-3Communication Protocol RS485 MODBUS, BACnetOperating Humidity 0 to 90% RH, non-condensingOperating Temperature 14° to 104°F (-10° to 40°C)Approvals UL Listed File #E190898, CE, RoHSEco Friendly YesWarranty 3 years
HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD WITH BYPASS
DESCRIPTION
The CORE VFD with a bypass option comes with a control transformer, time delay fuses, three contactors, primary and secondary fuses . CORE VFDs are an economical option drive option with easy to set up functionality . The firmware includes special features that make start-up and commissioning of HVAC applications especially easy . The Wizard consists of critical commissioning questions to intuitively guide users through a parameter setup process, which covers nearly all your commercial heating, ventilation and air conditioning (HVAC) applications . Additionally, the VFD CORE is rated for constant torque for industrial applications . The CORE line of VFDs is a time saver as well as an energy saver .
FEATURES
• Intuitive commissioning• Start-up wizard• Real-time clock• Detachable keypad• PID with sleep control
SPECIFICATIONS
Core VFD with Bypass
DIMENSIONS AND WEIGHTS
Frame 208/230 VAC 460 VACEnclosure NEMA type
Width in (cm)
Height in (cm)
Depth in (cm)
Weight lb (kg)
A 1.0 - 7.5 HP 1.0 - 10 HP NEMA 1 8.9 (22.7) 22.0 (55.9) 9.3 (23.6) 37.0 (16.78)
B 10 - 20 HP 15 - 25 HP NEMA 1 12.4 (31.6) 48.0 (121.9) 9.66 (24.5) 67.0(30.39)
C 25 - 40 hp 30 - 50 HP NEMA 1 12.4 (31.6) 48.0 (121.9) 9.66 (24.5) 83.0 (37.65)
D 50 - 60 HP 60 - 125 HP NEMA 1 19.5 (49.7) 53.5 (135.9) 11.4 (29.1) 193.0 (87.54)
E 75 - 125 HP NEMA 1 23.0 (48.3) 66.5 (168.9) 14.4 (36.7) 225 (102.06)
NEW!
699
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
Frame Sizes A, B, and C
R(L1)
S(L2)
T(L3)
FWD
R(L1)
S(L2)
T(L3)
NFB U(T1)
V(T2)
W(T3)
MOTOR
JUMPER
DC CHOKE(OPTIONAL) BREAKING RESISTOR
(OPTIONAL)
IM3~
REVMI1
FWD/STOPREV/STOP
3-PHASE POWER IS PROVIDED
FUSE/NO FUSE BREAKER
FACTORY SETTING:PNP SOURCE
PRESET SPD 1PRESET SPD 2PRESET SPD3
PRESET SPD 4EXT FAULTFAULT RESET
NANA
MI3MI2
MI4MI5MI6MI7MI8
MULTI-FUNCTIONOUTPUT TERMINALS
RA1
RB1
RC1
RA2
RC2
RA3
RC3
250VAC/6A
30VDC/6A
30VDC/5A
MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A
MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A
30VDC/5ADCM
SCM
S1
DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE
FACTORY SETTING
POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP
DIGITAL SIGNAL COMMON TERMINAL
+10V/20mA
0~10V/0~20mA
0-20mA/0~10V
ANALOG SIGNALCOMMON TERMINAL
3 21
5KΩ
MAIN CIRCUIT (POWER) TERMINALS
CONTROL TERMINALS
SHIELDED LEADS & CABLES
+10V
AVI1
ACI
AVI2 ACM
AFM1
ACM
AFM2ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA
ANALOG SIGNAL COMMON TERMINAL
ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA
OPTION SLOT 1
OPTION SLOT 3
COMMUNICATION EXTENSION CARD
I/O & RELAY EXTENSION CARD8 18 1MODBUS RS-485PIN 1~2, 7, 8: RESERVEDPIN 3, 6: GNDPIN 4: SG-PIN 5: SG+
SG+
SG-
0~+10V
COM
DCM
+24V
RA1 (RELAY OUT 1): RUNRA2 (RELAY OUT 2): FAULTRA3 (RELAY OUT 3): READY
MI: MULTIFUNCTION INPUTAVI: ANALOG VOLTAGE INPUTACI: ANALOG CURRENT INPUT
+24V
WIRING
HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD WITH BYPASS
NEW!MOTOR CONTROLS
700
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
Frame Sizes D and E
FWD
U(T1)
V(T2)
W(T3)
MOTOR
IM3~
REVMI1
FWD/STOPREV/STOP
3-PHASE POWER IS PROVIDED
R(L1)
S(L2)
T(L3)
R(L1)
S(L2)
T(L3)
NFB
FUSE/NO FUSE BREAKER
FACTORY SETTING:PNP SOURCE
PRESET SPD 1PRESET SPD 2PRESET SPD 3
PRESET SPD 4EXT FAULTFAULT RESET
NANA
MI3MI2
MI4MI5MI6MI7MI8
MULTI-FUNCTIONOUTPUT TERMINALS
RA1
RB1
RC1
RA2
RC2
RA3
RC3
250VAC/6A
30VDC/6A
30VDC/5A
250VAC/5A
MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A
MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 30VDC/5A
DCM
SCM
S1
DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE
FACTORY SETTING
POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP
DIGITAL SIGNAL COMMON TERMINAL
+10V/20mA
0~10V/0~20mA
0-20mA/0~10V
ANALOG SIGNALCOMMON TERMINAL
3 21
5KΩ
MAIN CIRCUIT (POWER) TERMINALS
CONTROL TERMINALS
SHIELDED LEADS & CABLES
+10V
AVI1
ACI
AVI2 ACM
AFM1
ACM
AFM2ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA
ANALOG SIGNAL COMMON TERMINAL
ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA
OPTION SLOT 1
OPTION SLOT 3
COMMUNICATION EXTENSION CARD
I/O & RELAY EXTENSION CARD8 18 1MODBUS RS-485PIN 1~2, 7, 8: RESERVEDPIN 3, 6: GNDPIN 4: SG-PIN 5: SG+
SG+
SG-
0~+10V
COM
DCM
+24V
+1/DC+ -/DC+
r
s
R
S
FRAME E
RA1 (RELAY OUT 1): RUNRA2 (RELAY OUT 2): FAULTRA3 (RELAY OUT 3): READY
MI: MULTIFUNCTION INPUTAVI: ANALOG VOLTAGE INPUTACI: ANALOG CURRENT INPUT
+24V
WIRING (continued)
HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD WITH BYPASS
NEW!
701
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
ORDERING INFORMATION
MODEL DESCRIPTIONHCRBA0010A1300T CORE VFD W/BYPASS/208V/1 HP/NEMA 1HCRBA0020A1300T CORE VFD W/BYPASS/208V/2HP/NEMA 1/FRAHCRBA0030A1300T CORE VFD W/BYPASS/208V/3HP/NEMA 1/FRAHCRBA0050A1300T CORE VFD W/BYPASS/208V/5HP/NEMA 1/FRAHCRBA0075A1300T CORE VFD W/BYPASS/208V/7.5HP/NEMA 1/FRAHCRBA0100B1300T CORE VFD W/BYPASS/208V/10HP/NEMA 1/FRBHCRBA0150B1300T CORE VFD W/BYPASS/208V/15HP/NEMA 1/FRBHCRBA0200B1300T CORE VFD W/BYPASS/208V/20HP/NEMA 1/FRBHCRBA0250C1300T CORE VFD W/BYPASS/208V/25HP/NEMA 1/FRCHCRBA0300C1300T CORE VFD W/BYPASS/208V/30HP/NEMA 1/FRCHCRBA0400C1300T CORE VFD W/BYPASS/208V/40HP/NEMA 1/FRCHCRBA0500D1300T CORE VFD W/BYPASS/208V/50HP/NEMA 1/FRDHCRBA0600D1300T CORE VFD W/BYPASS/208V/60HP/NEMA 1/FRDHCRBA0750E1300T CORE VFD W/BYPASS/208V/75HP/NEMA 1/FREHCRBA1000E1300T CORE VFD W/BYPASS/208V/100HP/NEMA 1/FREHCRBA1250E1300T CORE VFD W/BYPASS/208V/125HP/NEMA 1/FREHCRBB0010A1300T CORE VFD W/BYPASS/230V/1HP/NEMA 1/FRAHCRBB0020A1300T CORE VFD W/BYPASS/230V/2HP/NEMA 1/FRAHCRBB0030A1300T CORE VFD W/BYPASS/230V/3HP/NEMA 1/FRAHCRBB0050A1300T CORE VFD W/BYPASS/230V/5HP/NEMA 1/FRAHCRBB0075A1300T CORE VFD W/BYPASS/230V/7.5HP/NEMA 1/FRAHCRBB0100B1300T CORE VFD W/BYPASS/230V/10HP/NEMA 1/FRBHCRBB0150B1300T CORE VFD W/BYPASS/230V/15HP/NEMA 1/FRBHCRBB0200B1300T CORE VFD W/BYPASS/230V/20HP/NEMA 1/FRB
MODEL DESCRIPTIONHCRBB0250C1300T CORE VFD W/BYPASS/230V/25HP/NEMA 1/FRCHCRBB0300C1300T CORE VFD W/BYPASS/230V/30HP/NEMA 1/FRCHCRBB0400C1300T CORE VFD W/BYPASS/230V/40HP/NEMA 1/FRCHCRBB0500D1300T CORE VFD W/BYPASS/230V/50HP/NEMA 1/FRDHCRBB0600D1300T CORE VFD W/BYPASS/230V/60HP/NEMA 1/FRDHCRBB0750E1300T CORE VFD W/BYPASS/230V/75HP/NEMA 1/FREHCRBB1000E1300T CORE VFD W/BYPASS/230V/100HP/NEMA 1/FREHCRBB1250E1300T CORE VFD W/BYPASS/230V/125HP/NEMA 1/FREHCRBC0010A1300T CORE VFD W/BYPASS/460V/1HP/NEMA 1/FRAHCRBC0020A1300T CORE VFD W/BYPASS/460V/2HP/NEMA 1/FRAHCRBC0030A1300T CORE VFD W/BYPASS/460V/3HP/NEMA 1/FRAHCRBC0050A1300T CORE VFD W/BYPASS/460V/5HP/NEMA 1/FRAHCRBC0075A1300T CORE VFD W/BYPASS/460V/7.5HP/NEMA 1/FRAHCRBC0100A1300T CORE VFD W/BYPASS/460V/10HP/NEMA 1/FRAHCRBC0150B1300T CORE VFD W/BYPASS/460V/15HP/NEMA 1/FRBHCRBC0200B1300T CORE VFD W/BYPASS/460V/20HP/NEMA 1/FRBHCRBC0250B1300T CORE VFD W/BYPASS/460V/25HP/NEMA 1/FRBHCRBC0300C1300T CORE VFD W/BYPASS/460V/30HP/NEMA 1/FRCHCRBC0400C1300T CORE VFD W/BYPASS/460V/40HP/NEMA 1/FRCHCRBC0500C1300T CORE VFD W/BYPASS/460V/50HP/NEMA 1/FRCHCRBC0600D1300T CORE VFD W/BYPASS/460V/60HP/NEMA 1/FRDHCRBC0750D1300T CORE VFD W/BYPASS/460V/75HP/NEMA 1/FRDHCRBC1000D1300T CORE VFD W/BYPASS/460V/100HP/NEMA 1/FRDHCRBC1250D1300T CORE VFD W/BYPASS/460V/125HP/NEMA 1/FRD
Transformer
Three bypass contactorsshown (BC-1, BC-2, BC-3).BC-3 not supplied in a twocontactor bypass
M
HVFDSB3
Main Disconnect
L1
L2
L3
UVW
L1
L2
L3
BC-3 BC-1
BC-2
To factory wired bypass controls (switches, coils, etc.)
Note: Typical wiring shown. Refer to product installation manual for electrical wiring connections and requirements.
WIRING (continued)
HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD WITH BYPASS
NEW!MOTOR CONTROLS
702
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
Supply Voltage 208 to 230 VAC, 1 phase input - 3 phase output
380 to 480 VAC, 3 phase input/ output
Motor Rating 0 .25 - 7 .5 hpAcceleration Time 0 .1- 3000 secondsDeceleration Time 0 .1 - 3000 secondsFrequency Range 30 - 320 HzDigital Switch Inputs 6; 0 - 30 VDC programmableAnalog Inputs 2; (1) 0-10 VDC, (1) 0-20 mA or
4-20 mADigital Outputs 1 Open Collector, max . load 48V/
50mAAnalog Output 1, 0-20 mA or 4-20 mA, RL=500ΩRelay Outputs 2; (1) SPST N .O . (1) SPDT 250
VAC/2A, 250 VDC/0 .4A
Filter Type RFICommunication Protocol
RS485 (Modbus protocol), SerialOperating Humidity 0 to 90% RH (non-condensing)Operating Temperature 14° to 122°F (-10° to 50°C)Frame Size MI1, MI2, MI3Dimensions Frame sizes MI1 6 .1"H x 2 .6"W x 3 .9"D
(15 .5 x 6 .6 x 9 .9 cm) MI2 7 .7"H x 3 .5"W x 4 .0"D
(19 .6 x 8 .9 x 10 .2 cm) MI3 10 .3"D x3 .9"W x 4 .3"D
(26 .2 x 9 .9 x 10 .9 cm)Weights MI1 1 .20 lb (0 .55 kg) MI2 1 .50 lb (0 .65 kg) MI3 2 .18 lb (0 .99 kg)Approvals CE, UL, cUL FILE #E190898Warranty 3 years
HONEYWELL COMPACT VARIABLE FREQUENCY DRIVESMARTDRIVE COMPACT VFD
DESCRIPTIONThis compact VFD is a true micro drive, which saves space in the equipment cabinet and makes installation easy . The SmartDrive architecture allows for ease and speed in drive configuration . The intuitive user interface makes commissioning a breeze . The SmartDrive Compact VFD provides a standard PI Controller . Choose options to fit any application . Interface type, filter, enclosure, inputs, and outputs are available in a wide array of combinations . For wall mounting, a frame kit is recommended . Frame kits are not necessary for installation inside a panel .
FEATURES• Small, compact micro drive design• PI controller standard• No main power supply required for programming• Intuitive user interface• DIN rail or screw mounting• Flexible options include inputs, outputs, field bus, and
filtering• Application interface "touch wheel" makes
programming easy
SPECIFICATIONS
Terminal Signal Factory preset Description
1 +10Vre Ref. voltage out Maximum load 10 mA2 AI1 Analog signal in 1 Freq. reference P)
0 - +10 V Ri = 200 kΩ (min)
3 GND I/O signal ground6 24Vout 24V output for DI's
±20%, max. load 50 mA
7 GND I/O signal ground8 DI1 Digital input 1 Start forward P) 0 - +30 V Ri = 12 kΩ min9 DI2 Digital input 2 Start reverse P) 10 DI3 Digital input 3 Preset speed B0 P) A A RS485 signal A FB CommunicationB B RS485 signal B FB Communication4 AI2 Analog signal in 2 PI actual value P) 0(4) - 20 mA, Ri = 200Ω5 GND I/O signal ground13 GND I/O signal ground14 DI4 Digital input 4 Preset speed B1P) 0 - +30 V Ri = 12 kΩ (min)15 DI5 Digital input 5 Fault reset P)
16 DI6 Digital input 6 Disable PI contr. P)
18 AO Output frequency P) 0(4) - 20 mA, RL = 500Ω20 DO Digital signal out Active = READY P) Open collector, max. load
48V/50mA22 RO 11 Relay out 1 Active = RUN P) Max. switching load:
250 VAC/2A or 250 VDC/0.4A
23 RO 12
24 RO 21 Relay out 2 Active = FAULT P) Max. switching load:250 VAC/2A or 250 VDC/0.4A
25 RO 2226 RO 23
P) = Programmable function, see parameter lists and descriptions in installation manual.
mA
API FULL
Note: NEMA 1 frame kits include the top protection from vertically dripping water with additional physical contact protection over the wiring terminals . Recommended for non-enclosed VFD mounting .
CONTROL I/O
NEW!
703
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
HONEYWELL COMPACT VARIABLE FREQUENCY DRIVESMARTDRIVE COMPACT VFD
ORDERING INFORMATION
Full IO Model Limited IO Model Supply Voltage Current Rating
Horsepower EMCFrame Size
HVFDCD1B0003F00 HVFDCD1B0003L00 208 to 230 VAC, 1 phase input - 3 phase output 1.7A 0.25 NO MI1
HVFDCD1B0003F01 HVFDCD1B0003L01 208 to 230 VAC, 1 phase input - 3 phase output 1.7A 0.25 YES MI1
HVFDCD1B0005F00 HVFDCD1B0005L00 208 to 230 VAC, 1 phase input - 3 phase output 2.4A 0.5 NO MI1
HVFDCD1B0005F01 HVFDCD1B0005L01 208 to 230 VAC, 1 phase input - 3 phase output 2.4A 0.5 YES MI1
HVFDCD1B0007F00 HVFDCD1B0007L00 208 to 230 VAC, 1 phase input - 3 phase output 2.8A 0.75 NO MI1
HVFDCD1B0007F01 HVFDCD1B0007L01 208 to 230 VAC, 1 phase input - 3 phase output 2.8A 0.75 YES MI1
HVFDCD1B0010F00 HVFDCD1B0010L00 208 to 230 VAC, 1 phase input - 3 phase output 3.7A 1 NO MI1
HVFDCD1B0010F01 HVFDCD1B0010L01 208 to 230 VAC, 1 phase input - 3 phase output 3.7A 1 YES MI1
HVFDCD1B0015F00 HVFDCD1B0015L00 208 to 230 VAC, 1 phase input - 3 phase output 4.8A 1.5 NO MI2
HVFDCD1B0015F01 HVFDCD1B0015L01 208 to 230 VAC, 1 phase input - 3 phase output 4.8A 1.5 YES MI2
HVFDCD1B0020F00 HVFDCD1B0020L00 208 to 230 VAC, 1 phase input - 3 phase output 7.0A 2 NO MI2
HVFDCD1B0020F01 HVFDCD1B0020L01 208 to 230 VAC, 1 phase input - 3 phase output 7.0A 2 YES MI2
HVFDCD1B0030F00 HVFDCD1B0030L00 208 to 230 VAC, 1 phase input - 3 phase output 11.0A 3 NO MI3
HVFDCD1B0030F01 HVFDCD1B0030L01 208 to 230 VAC, 1 phase input - 3 phase output 11.0A 3 YES MI3
HVFDCD3C0005F00 HVFDCD3C0005L00 380 to 480 VAC, 3 phase input/ output 1.3A 0.5 NO MI1
HVFDCD3C0005F01 HVFDCD3C0005L01 380 to 480 VAC, 3 phase input/ output 1.3A 0.5 YES MI1
HVFDCD3C0007F00 HVFDCD3C0007L00 380 to 480 VAC, 3 phase input/ output 1.9A 0.75 NO MI1
HVFDCD3C0007F01 HVFDCD3C0007L01 380 to 480 VAC, 3 phase input/ output 1.9A 0.75 YES MI1
HVFDCD3C0010F00 HVFDCD3C0010L00 380 to 480 VAC, 3 phase input/ output 2.4A 1 NO MI1
HVFDCD3C0010F01 HVFDCD3C0010L01 380 to 480 VAC, 3 phase input/ output 2.4A 1 YES MI1
HVFDCD3C0015F00 HVFDCD3C0015L00 380 to 480 VAC, 3 phase input/ output 3.3A 1.5 NO MI1
HVFDCD3C0015F01 HVFDCD3C0015L01 380 to 480 VAC, 3 phase input/ output 3.3A 1.5 YES MI1
HVFDCD3C0020F00 HVFDCD3C0020L00 380 to 480 VAC, 3 phase input/ output 4.3A 2 NO MI2
HVFDCD3C0020F01 HVFDCD3C0020L01 380 to 480 VAC, 3 phase input/ output 4.3A 2 YES MI2
HVFDCD3C0030F00 HVFDCD3C0030L00 380 to 480 VAC, 3 phase input/ output 5.6A 3 NO MI2
HVFDCD3C0030F01 HVFDCD3C0030L01 380 to 480 VAC, 3 phase input/ output 5.6A 3 YES MI2
HVFDCD3C0040F00 HVFDCD3C0040L00 380 to 480 VAC, 3 phase input/ output 7.6A 4 NO MI3
HVFDCD3C0040F01 HVFDCD3C0040L01 460 to 480 VAC, 3 phase input/ output 7.6A 4 YES MI3
HVFDCD3C0050F00 HVFDCD3C0050L00 460 to 480 VAC, 3 phase input/ output 9.0A 5 NO MI3
HVFDCD3C0050F01 HVFDCD3C0050L01 460 to 480 VAC, 3 phase input/ output 9.0A 5 YES MI3
HVFDCD3C0075F00 HVFDCD3C0075L00 460 to 480 VAC, 3 phase input/ output 12.0A 7.5 NO MI3
HVFDCD3C0075F01 HVFDCD3C0075L01 460 to 480 VAC, 3 phase input/ output 12.0A 7.5 YES MI3
ACCESSORIESHVFDCABLE Commissioning cable and USB adaptorHVFDCDMCA VFD commissioning deviceHVFDCDMCAKIT Commisioning kitHVFDCDNEMA1FR1 Enclosure upgrade Nema 1 kit frame size1HVFDCDNEMA1FR2 Enclosure upgrade Nema 1 kit frame size2HVFDCDNEMA1FR3 Enclosure upgrade Nema 1 kit frame size3
NEW!MOTOR CONTROLS
704
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVESSMARTVFD HVAC
Supply Voltage Model specific, 3 phase, 60 Hz, 380-480 VAC or 200-240 VAC
Motor Rating 0 .75 to 250 HpFrequency Range 0-320 HzAcceleration Time 0 .1 - 3000 secondsDeceleration Time 0 .1 - 3000 secondsDigital Inputs 6 logical, 24 VDC= on, 0 VDC= off,
all configurableAnalog Input 2; 0-10V or 4-20 mA voltage input impedance 200Ω k current impedance 250ΩDigital Output Open collector,
max . load 48V/ 50 mAAnalog Output 1; 0-10 VDC or 4-20 mA
programmable 500Ω maximum loadRelay Outputs 2; SPDT 8A at 24 VDC or 250 VAC 0 .4A at 125 VDC minimum load 10mA at 5 VAC/VDCFilter Type 5% DC choke Class 2 GMC/ RFIEMC Complies with EN50082-1, -2 EN61800-3Communication Protocol RS485 JCI N2, MODBUS, BACnet MS/TP Ethernet BACnet/ IP, Modbus/TCPOperating Humidity 0 to 95% RH (non-condensing)Operating Temperature 14° to 104°F (-10° to 40°C)Approvals UL Listed File E190898 CE RoHSEco Friendly YesWarranty 3 years
DESCRIPTION
SmartVFD HVAC drives are all-purpose, and can handle both constant-torque and variable-torque loads . The firmware includes special features that make start-up and commissioning of HVAC applications especially easy . Application-specific startup wizards for pumps and fans, combined with the simple and intuitive user interface, make the SmartVFD a pleasure rather than a chore . Integration is a snap with the SmartVFD . It includes both Ethernet and RS485 connections, and will talk BACnet, Modbus, and JCI N2 . Take the complexity out of drive selection, installation, and startup - choose SmartVFD for your HVAC projects and start saving time, money, and manpower as well as energy .
FEATURES
• Intuitive commissioning• High resolution graphic interface• User manual included in firmware• Simple start-up wizard - pump or fan• Fire mode• 2 PID controllers • Real-time clock
SPECIFICATIONS
Terminal Signal Technical information
1 Reference output +10 VDC, +3%; Maximum current 10 mA
2Analog input,
voltage or current
Analog input channel 1; Short-circuited protected
0- +10VDC (Ri = 200 kΩ)
4-20 mA (Ri = 250 Ω)
Resolution 0.1%, accuracy ±1%
Selection V/mA with dip-switches
3Analog input
common (current)
Differential input if not connected to ground;
Allows ±20V differential mode voltage to GND
4Analog input
voltage or current
Analog input channel 2; Short-circuited protected
Default: 4-20 mA (Ri =250 Ω)
0-10 VDC (Ri = 200kΩ)
Resolution 0.1%, accuracy ±1%
Selection V/mA with dip-switches
5Analog input
common (current)
Differential input if not connected to ground;
Allows 20V differential mode voltage to GND
6 24VDC aux. voltage
+24 VDC, ±10%, max volt. ripple < 100mVrms; max. 250mA
Dimensioning: max. 1000mA/control unit.
Short-circuit protected
7 I/O groundGround for reference and controls (connected internally to
frame earth through 1MΩ)
8 Digital input 1 Positive or negative logic
Ri = min. 5kΩ
0...5VDC = “0”
15…30VDC = “1”
9 Digital input 2
10 Digital input 3
11Common A for
DIN1-DIN6
Digital inputs can be disconnected from ground
12 24 VDC aux. voltage
+24 VDC, ±10%, max volt. ripple < 100mVrms; max. 250mA
Dimensioning: max. 1000mA/control unit.
Short-circuit protected
13 I/O groundGround for reference and controls (connected internally to
frame earth through 1MΩ)
14 Digital input 4 Positive or negative logic
Ri = min. 5kΩ
0...5VDC = “0”
15…30VDC = “1”
15 Digital input 5
16 Digital input 6
17Common A for
DIN1-DIN6Digital inputs can be isolated from ground.
18Analog signal
(+output)Analog output channel 1, selection 0 -20mA, load <500Ω
Default: 0-20 mA/0-10 VDC
Resolution 0.1%, accuracy ±2%
Selection V/mA with dip-switches
Short-circuited protected.19
Analog output
common
3024 VDC auxiliary
input voltageCan be used as external power backup for the control unit
A RS485 Differential receiver/transmitter
Set bus termination with dip switchesB RS485
STANDARD I/O BOARD
NEW!
705
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVESSMARTVFD HVAC
Relay
board
21Relay
Output 1*
Switching capacity 2 4VDC/8A250 VAC/8A125 VDC/0.4AMin.switching load 5V/10mA
22
23
24Relay
Output 2*
Switching capacity 24 VDC/8A250 VAC/8A125 VDC/0.4AMin.switching load 5V/10mA
25
26
28 ThermistorInput
Rtrip = 4.7 kΩ (PTC); Measuring voltage 3.5V29
* If 230VAC is used as control voltage from the output relays, the control circuitry must be powered with a separate isolation transformer to limit short circuit current and ovrvoltage spikes. This is to prevent welding on the relay contacts. Refer to standard EN 60204-1, section 7.2.9
Relay board with two change-over contact (SPDT) relays and one relay with normally-open (NO or SPST) contact. 5.5 mm isolation between channels.
RelayBoardTerminal Signal
21 RO1/1 Relay output 1
22 RO1/2
23 RO1/3
24 RO2/1 Relay output 2
25 RO2/2
26 RO2/3
28 TI1+Thermistor input
29 TI1-
From Standard I/O board
From term.
#13
From term.
#12
RUN
DIMENSIONS AND WEIGHTS
RELAY BOARD TECHNICAL INFORMATION RELAY CONNECTIONS
Frame 208/ 230 VAC 460 VACEnclosure NEMA type
Width in. (cm)
Height in. (cm)
Depth in. (cm)
Weight lb (kg)
4 0.75-4 HP 1.5-7.5 HP 1 5 (12.7) 12.9 (32.77) 7.5 (19.05) 13.0 (5.9)4 0.75-4 HP 1.5-7.5 HP 12 5 (12.7) 12.9 (32.77) 7.5 (19.05) 13.0 (5.9)4 0.75-4 HP 1.5-7.5 HP 3 20.5 (52.07) 20 (50.8) 10 (25.4) 13.0 (5.9)5 5-10 Hp 10-20 Hp 1 5.7 (14.48) 16.5 (41.91) 8.4 (21.34) 22.0 (10.0)5 5-10 Hp 10-20 Hp 12 5.7 (14.48) 16.5 (41.91) 8.4 (21.34) 22.0 (10.0)5 5-10 Hp 10-20 Hp 3 20.5 (52.07) 24 (60.96) 10 (25.4) 22.0 (10.0)6 15-20 Hp 25-40 Hp 1 7.7 (19.56) 21.9 (55.63) 9 (22.86) 44.0 (20.0)6 15-20 Hp 25-40 Hp 12 7.7 (19.56) 21.9 (55.63) 9 (22.86) 44.0 (20.0)6 15-20 Hp 25-40 Hp 3 28.5 (72.39) 36 (88.9) 10 (25.4) 44.0 (20.0)7 25-40 Hp 50-75 Hp 1 9.3 (23.62) 25.4 (64.51) 10.2 (25.91) 83.0 (37.7)7 25-40 Hp 50-75 Hp 12 9.3 (23.62) 25.4 (64.51) 10.2 (25.91) 83.0 (37.7)7 25-40 Hp 50-75 Hp 3 28.8 (73.15) 48 (121.92) 12 (30.48) 83.0 (37.7)8 50-75 Hp 100-150 Hp 1 11.4 (28.96) 38 (96.52) 13.5 (34.29) 154.0 (70.0)8 50-75 Hp 100-150 Hp 12 11.4 (28.96) 38 (96.52) 13.5 (34.29) 154.0 (70.0)8 50-75 Hp 100-150 Hp 3 11.4 (28.96) 38 (96.52) 13.5 (34.29) 154.0 (70.0)9 100-125 Hp 200-250 Hp 1 18.9 (48.00) 45.3 (115.06) 14.4 (36.58) 238.0 (108.2)9 100-125 Hp 200-250 Hp 12 18.9 (48.00) 45.3 (115.06) 14.4 (36.58) 238.0 (108.2)
NEW!MOTOR CONTROLS
706
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
ORDERING INFORMATION
HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVESSMARTVFD HVAC
HP Amps Frame NEMA 1 NEMA 12 NEMA3R
460 VAC1.5 3.4 4 HVFDSD3C0015G100 HVFDSD3C0015G200 HVFDSD3C0015G300
2 4.8 4 HVFDSD3C0020G100 HVFDSD3C0020G200 HVFDSD3C0020G300
3 5.6 4 HVFDSD3C0030G100 HVFDSD3C0030G200 HVFDSD3C0030G300
4 8 4 HVFDSD3C0040G100 HVFDSD3C0040G200 HVFDSD3C0040G300
5 9.6 4 HVFDSD3C0050G100 HVFDSD3C0050G200 HVFDSD3C0050G300
7.5 12 4 HVFDSD3C0075G100 HVFDSD3C0075G200 HVFDSD3C0075G300
10 16 5 HVFDSD3C0100G100 HVFDSD3C0100G200 HVFDSD3C0100G300
15 23 5 HVFDSD3C0150G100 HVFDSD3C0150G200 HVFDSD3C0150G300
20 31 5 HVFDSD3C0200G100 HVFDSD3C0200G200 HVFDSD3C0200G300
25 38 6 HVFDSD3C0250G100 HVFDSD3C0250G200 HVFDSD3C0250G300
30 46 6 HVFDSD3C0300G100 HVFDSD3C0300G200 HVFDSD3C0300G300
40 61 6 HVFDSD3C0400G100 HVFDSD3C0400G200 HVFDSD3C0400G300
50 72 7 HVFDSD3C0500G100 HVFDSD3C0500G200 HVFDSD3C0500G300
60 87 7 HVFDSD3C0600G100 HVFDSD3C0600G200 HVFDSD3C0600G300
75 105 7 HVFDSD3C0750G100 HVFDSD3C0750G200 HVFDSD3C0750G300
100 140 8 HVFDSD3C1000G100 HVFDSD3C1000G200 HVFDSD3C1000G300
125 170 8 HVFDSD3C1250G100 HVFDSD3C1250G200 HVFDSD3C1250G300
150 205 8 HVFDSD3C1500G100 HVFDSD3C1500G200 HVFDSD3C1500G300
200 261 9 HVFDSD3C2000G100 HVFDSD3C2000G200 -
250 310 9 HVFDSD3C2500G100 HVFDSD3C2500G200 -
208/ 230 VAC0.75 3.7 4 HVFDSD3A0007G100 HVFDSD3A0007G200 HVFDSD3A0007G300
1 4.8 4 HVFDSD3A0010G100 HVFDSD3A0010G200 HVFDSD3A0010G300
1.5 6.6 4 HVFDSD3A0015G100 HVFDSD3A0015G200 HVFDSD3A0015G300
2 8 4 HVFDSD3A0020G100 HVFDSD3A0020G200 HVFDSD3A0020G300
3 11 4 HVFDSD3A0030G100 HVFDSD3A0030G200 HVFDSD3A0030G300
5 18 5 HVFDSD3A0050G100 HVFDSD3A0050G200 HVFDSD3A0050G300
7.5 24 5 HVFDSD3A0075G100 HVFDSD3A0075G200 HVFDSD3A0075G300
10 31 5 HVFDSD3A0100G100 HVFDSD3A0100G200 HVFDSD3A0100G300
15 48 6 HVFDSD3A0150G100 HVFDSD3A0150G200 HVFDSD3A0150G300
20 62 6 HVFDSD3A0200G100 HVFDSD3A0200G200 HVFDSD3A0200G300
25 75 7 HVFDSD3A0250G100 HVFDSD3A0250G200 HVFDSD3A0250G300
30 88 7 HVFDSD3A0300G100 HVFDSD3A0300G200 HVFDSD3A0300G300
40 105 7 HVFDSD3A0400G100 HVFDSD3A0400G200 HVFDSD3A0400G300
50 140 8 HVFDSD3A0500G100 HVFDSD3A0500G200 HVFDSD3A0500G300
60 170 8 HVFDSD3A0600G100 HVFDSD3A0600G200 HVFDSD3A0600G300
75 205 8 HVFDSD3A0750G100 HVFDSD3A0750G200 HVFDSD3A0750G300
100 261 9 HVFDSD3A1000G100 HVFDSD3A1000G200 -
125 310 9 HVFDSD3A1250G100 HVFDSD3A1250G200 -
Drives are typically sized to match the horsepower rating of the motor, which will be accurate 95 percent of the time. For greatest accuracy, drives should be sized based upon the Full Load Amps or current draw of the motor. The VFD must have a slightly larger current rating maximum.
ACCESSORIES32006630-001 LON communication cardHVFDCABLE Commissioning cable and USB adaptor
NEW!
707
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
Transformer
Three bypass contactorsshown (BC-1, BC-2, BC-3).BC-3 not supplied in a twocontactor bypass
M
HVFDSB3
Main Disconnect
L1
L2
L3
UVW
L1
L2
L3
BC-3 BC-1
BC-2
To factory wired bypass controls (switches, coils, etc.)
WIRING
Supply Voltage 208 VAC, 3 phase, 60 Hz 230 VAC, 3 phase, 60 Hz 480 VAC, 3 phase, 60HzMotor Rating 1 .0 to 250 HpFrequency Range 0 - 320 HzAcceleration Time 0 .1 - 3000 secondsDeceleration Time 0 .1 - 3000 secondsDigital Inputs 6 factory presetAnalog Input 2; 0-10V or 4-20 mA programmableDigital Output Open collector,
max . load 48V / 50 mAAnalog Output 1; 4-20 mA
Relay Outputs 2 each SPDT 8A at 24 VDC or 250 VAC 0 .4A at 125 VDC Minimum load 10Ma at 5 VAC/VDC
Filter Type 5% DC choke , and class 2 GMC/RFIEMC Complies with EN50082-1, -2Communication Protocol RS485 BACnet MS/TP, N2, Modbus Ethernet BACnet/ IP, Modbus/TCPOperating Humidity 0 to 95% RH (non-condensing)Operating Temperature 14° to 104°F (-10° to 40°C)Approvals UL Listed File #E190898 cUL CE
RoHSEco Friendly YesWarranty 3 years
HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASSSMARTVFD HVAC WITH BYPASS ASSEMBLY
DESCRIPTION
Honeywell’s integral bypass and disconnect system make applying the SmartVFD drive a snap . Available with a simple fused disconnect switch, a 2-contactor bypass assembly, or a 3-contactor bypass assembly, it simplifies installation . All the features of the SmartVFD are included -- a wide array of configurable inputs and outputs, and all the most popular network protocols, and the super easy startup wizards that speed commissioning . All drives feature Hand-Off-Auto operation as a is fully integrated keypad function . Make the SmartVFD choice for your variable speed drive needs .
FEATURES
• Disconnect, 2-, or 3-contactor bypass• Fused disconnect• Auto bypass available• Available in NEMA 1, 12, or 3R enclosure types• Compact size• SmartVFD wizard for pump or fan control• Intuitive commissioning• High resolution graphic interface• User manual built in to firmware
SPECIFICATIONS
Note: Typical wiring shown . Refer to product installation manual for electrical wiring connections and requirements .
NEW!MOTOR CONTROLS
708
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
Our five configurations make it easy for you to select the right bypass to complete your drive package . All bundles are available in NEMA 1, NEMA 12 and ventilated NEMA 3R HOA (HAND OFF AUTO) .
SmartVFD Disconnect Only• Adds a fused disconnect to the VFD .
SmartVFD 2-Contactor BypassProvides an economical means of bypassing the VFD .• Freeze/Fire/Smoke Interlock
SmartVFD 3-Contactor BypassCommission, service or replace the VFD without affecting the operation of the motor .• Fused Disconnect• Freeze/Fire/Smoke Interlock• VFD is isolated from power with motor running in BYPASS
mode• TEST position powers the VFD without sending power to the
motor
SmartVFD 3-Contactor Bypass with Auto-BypassThe package adds the control capabilities below to the standard three contactor bypass .• Any VFD fault will automatically send the bypass to BYPASS
mode• A contact closure sends the bypass to BYPASS mode• Dry contacts indicate when the bypass is in BYPASS mode,
alerting the building management system
SMART VFD BYPASS CONFIGURATIONS
HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASSSMARTVFD HVAC WITH BYPASS ASSEMBLY
DIMENSIONS - IN (CM)
Frame Size
Horsepower and Voltage NEMA 1 NEMA 12 NEMA 3 R
208/ 230 VAC 460 VAC Configuration Width Height Depth Width Height Depth Width Height Depth
4 0.75-4 Hp 1.5-7.5 HpDisconnect 8.9 (22.6) 8.9 (22.6) 10.7 (26.2) 12.0 (29.4) 36.0 (88.2) 8.8 (21.6) 20.5 (50.2) 20.0 (49.0) 10.0 (24.5)
2-Contactor 8.9 (22.6) 8.9 (22.6) 10.7 (26.2) 16.0 (39.2) 36.0 (88.2) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5)
3-Contactor, 3-Contactor
w/ Auto- Bypass8.9 (22.6) 8.9 (22.6) 10.7 (26.2) 16.0 (39.2) 36.0 (88.2) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5)
5 5-10Hp 10-20 HpDisconnect 8.9 (22.6) 34.5 (84.5) 10.7 (26.2) 12.0 (29.4) 40.0 (98) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5)
2-Contactor 8.9 (22.6) 34.5 (84.5) 10.7 (26.2) 16.0 (39.2) 44.0 (107.8) 8.8 (21.6) 28.5 (69.8) 30.0 (73.5) 10.0 (24.5)
3-Contactor, 3-Contactor
w/ Auto- Bypass8.9 (22.6) 41.5 (101.7) 10.7 (26.2) 16.0 (39.2) 44.0 (107.8) 8.8 (21.6) 28.5 (69.8) 30.0 (73.5) 10.0 (24.5)
6 15-20Hp 25-40 HpDisconnect 12.4 (30.4) 45.0 (110.3) 12.6 (30.9) 16.0 (39.2) 46.0 (112.7) 10.8 (26.5) 28.5 (69.8) 36.0 (88.2) 10.0 (24.5)
2-Contactor 12.4 (30.4) 45.0 (110.3) 12.6 (30.9) 20.0 (49.0) 54.0 (132.3) 10.8 (26.5) 34.5 (84.5) 36.0 (88.2) 10.0 (24.5)
3-Contactor, 3-Contactor
w/ Auto- Bypass12.4 (30.4) 55.0 (134.8) 12.6 (30.9) 20.0 (49.0) 54.0 (132.3) 10.8 (26.5) 34.5 (84.5) 36.0 (88.2) 10.0 (24.5)
7 25-40Hp 50-75 HpDisconnect 20.84 (51.1) 51.5 (126.2) 11.4 (27.9) 16.0 (39.2) 50.0 (122.5) 11.8 (28.9) 28.5 (69.8) 48.0 (117.6) 12.0 (29.4)
2-Contactor 20.84 (51.1) 51.5 (126.2) 11.4 (27.9) 24.0 (58.8) 64.0 (156.8) 13.6 (33.3) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)
3-Contactor, 3-Contactor
w/ Auto- Bypass20.84 (51.1) 59.0 (144.6) 11.4 (27.9) 24.0 (58.8) 64.0 (156.8) 13.6 (33.3) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)
8 50-75 Hp 100-150 HpDisconnect 25.0 (61.3) 60.0 (147.0) 16.2 (39.7) 20.0 (49.0) 64.0 (156.8) 15.1 (36.9) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)
2-Contactor 25.0 (61.3) 60.0 (147.0) 16.2 (39.7) 56.0 (137.2) 48.0 (117.6) 15.1 (36.9) 40.4 (98.9) 60.0 (147.0) 12.0 (29.4)
3-Contactor, 3-Contactor
w/ Auto- Bypass25.0 (61.3) 70.0 (171.5) 16.2 (39.7) 56.0 (137.2) 48.0 (117.6) 15.1 (36.9) 40.4 (98.9) 60.0 (147.0) 12.0 (29.4)
NEW!
709
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASSSMARTVFD HVAC WITH BYPASS ASSEMBLY
ORDERING INFORMATION
Example: HVDSB3C0400G130 480 VAC, 40 Hp, Smart VFD NEMA 1with graphic keypad display, 3 contractor bypass
HVFDSB3 Honeywell SmartVFD HVAC
A 208 VAC - up to 75 Hp
B 230 VAC - up to 75 Hp
C 480 VAC - up to 150 Hp
Motor Horsepower
0007 .75 Hp 208, 230 & 480 VAC
0010 1 Hp 208, 230 & 480 VAC
0015 1.5 Hp 208, 230 & 480 VAC
0020 2 Hp 208, 230 & 480 VAC
0030 3 Hp 208, 230 & 480 VAC
0040 4 Hp 208, 230 & 480 VAC
0050 5 Hp 208, 230 & 480 VAC
0075 7.5 Hp 208, 230 & 480 VAC
0100 10 Hp 208, 230 & 480 VAC
0150 15 Hp 208, 230 & 480 VAC
0200 20 Hp 208, 230 & 480 VAC
0250 25 Hp 208, 230 & 480 VAC
0300 30 Hp 208, 230 & 480 VAC
0400 40 Hp 208, 230 & 480 VAC
0500 50 Hp 208, 230 & 480 VAC
0600 60 Hp 208, 230 & 480 VAC
0750 75 Hp 208, 230 & 480 VAC
1000 100 Hp 480 VAC
1250 125 Hp 480 VAC
1500 150 Hp 480 VAC
User Interface
G Graphic User Interface
Enclosure
1 NEMA 1
2 NEMA 12
3 NEMA 3R
Options
10 Disconnect only
20 Drive with 2 contractor BYPASS
30 Drive with 3 contactor BYPASS
31 Drive with 3 contactor BYPASS, w/ Fused disconnect and Auto-bypass
HVFDSB3 C 0400 G 1 30
ACCESSORIES PAGE32006630-001 LON communication card HVFDCABLE Commissioning cable and USB adaptor
NEW!MOTOR CONTROLS
710
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
MOTOR CONTROL ACRONYMS, CALCULATIONS & CONVERSION FORMULAS
AC = alternating current
ANSI = American National Standards Institute
ASD = adjustable speed drive
BHP = brake horsepower
CFM = cubic feet per minute
CSA = Canadian Standards Association
CSI = current source inverter
DC = direct current
DSP = digital signal processor
ECC = eddy current coupling
FPM = feet per minute
GPM = gallon per minute
GTO = gate turnoff (thyristor)
HDF = harmonic distortion factor
IGBT = insulated gate bi-thermal thyristor
IEEE = Institute of Electrical and Electronics Engineers
LCI = load-commutated inverter
NEMA = National Electrical Manufacturers Association
NPV = net present value
PAM = pulse amplitude modulation
PLC = programmable logic controller
PWM = pulse width modulated (inverter)
SCR = silicon-controlled rectifier
SR = switched reluctance
THD = total harmonic distortion
V = voltage
VSI = variable source inverter
VVI = variable voltage inverter
Calculating the Horsepower Requirement of a Load
The mechanical load required by the driven equipment is known as the Brake Horsepower (BHP) . The BHP value can be calculated by the following: BHP = T x N (required HP) 5,250
Where: HP = horsepower supplied by the motor T = Torque (lb-ft) force x radius N = base speed of motor (rpm)
Once the machine BHP (speed times torque) requirement is determined, horsepower (HP) can be calculated:
Rated motor HP = Motor Efficiency (%) / 100 = available HP
If the calculated horsepower falls between standard available motor ratings, select the higher available horsepower rating . It is good practice to allow some margin when selecting the motor horsepower .
CONVERSION FORMULAS/FACTORS
Multiply By To ObtainLength Meters 3.281 Feet
Meters 39.37 Inches
Inches 0.025 Meters
Feet 0.305 Meters
Torque Newton-Meters 0.738 lb-ft
lb-ft 1.356 Newton-Meters
lb-in 0.083 lb-ft
lb-ft 12.00 lb-in
Rotation RPM 6.00 Degrees per second
RPM 0.105 Radius per second
Degrees per second 0.167 RPM
Radius per second 9.549 RPM
Power Watts 0.001 HP
lb-ft per minute 0.000 HP
HP 746 Watts
HP 30300 lb-ft/min
Temperature Degrees C = (Degrees F-32) x 5/9Degrees F = (Degrees C x 9/5) + 32
NEW!
711
MOTOR CONTROLSM
OTO
R CONTRO
LS
12
WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014
GLOSSARY OF COMMON TERMS
Alternating Current: The flow of electricity which changes direction on a regular continuous cycle reaching a maximum in one direction, decreasing to zero, then reversing to reach a maximum in the opposite direction .
Air Gap: The space between the rotating and stationary part of an electric motor . Magnetic energy is transferred across this gap .
Ambient: The air which surrounds a motor for air cooled machines .
Ampere: A unit of current which is a measure of the rate of electron flow . It is often abbreviated as Amp . The unit of current flow is the amp .
Breakdown Torque: The maximum torque that a motor can develop at rated voltage without stalling or an abrupt drop in speed .
Brush: A current carrying material which is in contact with an armature or slip ring assembly to provide an elec-trical connection between rotating and stationary components of a motor . Capacitor: A device which can store electrical charge . In an AC circuit, a capacitor causes the voltage to lead the current . The unit of capacitance is the Farad .
Commutator: An assembly which is mounted on the shaft of a DC motor to provide the switching functions between the armature coils and the power supply .
Conductor: Any material which offers little resistance to the flow of electricity such as copper .
Duty Cycle: The relationship between the operating time and the resting time of an electric motor .
Eddy Current: Localized currents in electrical steels that are caused by alternating magnetic flux resulting in losses and heating .
Efficiency: The ratio of mechanical output to the electrical input power of a motor .
Electromotive Force (emf): A synonym for voltage usually used to describe induced or generated voltages in an electric circuit .
Field: The term used to describe the stationary part of a DC machine . The field provides the magnetic flux which interacts with the armature .
Flux: The magnetic field which is established around a current carrying conductor or a permanent magnet .
Frequency: The rate at which alternating current reverses its direction of flow . The unit of frequency is either Hertz or cycles per second .
Full Load Current: The current that a motor draws at rated voltage, frequency and load .
Full Load Slip: The difference between the synchronous speed of a motor and full load speed . It is often ex-pressed as a ratio of the synchronous speed to full load speed in percent .
Full Load Speed: The speed of the motor at rated voltage, frequency and load .
Full Load Torque: The torque that is necessary to produce rated horsepower at full load speed .
Horsepower: A measurement of power used to rate electric motors . The unit of power rating in motors is either horsepower or kilowatts . One horsepower is equal to 746 watts .
NEW!MOTOR CONTROLS
712
NEW!M
OTO
R CO
NTRO
LS
12
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014
Impedance: The total opposition a circuit offers to the flow of alternating current . It is the vector sum of resis-tance and reactance .
Inductance: The property of an electrical circuit which opposes a change in current due to the magnetic field induced by that current .
Inertia: Inertia is the resistance an object has to a change in its state of motion . It is determined by the weight of the object multiplied by the square of the radius of gyration (k) . Rotating parts do not operate at the same speed, therefore calculating the inertia for each moving part allows rotating parts to be considered as a single unit work-ing together .
Line Voltage: The voltage supplied to the input terminals of an electric device .
Magnetomotive Force (mmf): The magnetic energy supplied in the establishment of magnetic flux . It is analo-gous to the electromotive force in an electric circuit .
Phase: A term used to describe the spatial relationship of windings in an electric motor or voltages and currents in an electric circuit .
Power Factor: A measurement of the difference in phase between voltage and current in an electric circuit . Most electrical devices cause the current to lag the voltage because of inductance . The voltage leads the cur-rent in capacitive circuits .
Reactance (inductive): The property of a magnetic circuit which causes the voltage to lag the current .
Resistance: The property of an electrical conductor which impedes the flow of electricity . The unit of resistance is the ohm .
Rotor: The rotating member of an electric motor .
Service Factor: The service factor of an AC motor is a multiplier which when applied to the rated horsepower indicates the permissible loading which may be carried under the conditions specified for the service factor .
Slip: The ratio between the synchronous speed and the operating speed of an induction motor, often expressed as a percent .
Stator: The stationary part of an AC motor housing the steel laminations and the windings .
Temperature Rise: The difference between the temperature of the windings of an operating motor and the am-bient temperature .
Torque: The turning force applied to a shaft, usually expressed as pound-feet (English) or Newton-meters (met-ric) .
Voltage: The standard unit of electromotive force which produces a flow of current in a conductor . The unit of electromotive force is the volt .
Watt: A measurement of power in an electrical circuit which is equal to one joule of energy being expended in one second .
GLOSSARY OF COMMON TERMS