+ All Categories
Home > Documents > HYDRO GEO CHEM INC. by Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils...

HYDRO GEO CHEM INC. by Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils...

Date post: 16-Dec-2015
Category:
Upload: shannon-byrd
View: 217 times
Download: 2 times
Share this document with a friend
Popular Tags:
47
HYDRO GEO CHEM INC. by www.hgcinc.com Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills Harold Bentley, Stewart Smith Hydro Geo Chem, Inc. Tucson and Scottsdale, Arizona Presented at the Desert Remedial Action Technologies Workshop Phoenix, Arizona October 2-4, 2007
Transcript
Page 1: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

by

www.hgcinc.com

Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and

Groundwater Underlying Desert Landfills

Harold Bentley, Stewart Smith

Hydro Geo Chem, Inc.

Tucson and Scottsdale, Arizona

Presented at theDesert Remedial Action Technologies Workshop

Phoenix, Arizona October 2-4, 2007

Page 2: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

First, you’ve got to understand the plumbing! ---King Hubbard, Father of American Hydrogeology

This presentation discusses a quantitative in-situ remediation methodology that relies on site-specific evaluation and numerical simulation to1. develop critical insights regarding the conceptual model of the contamination problem, and 2. to develop and optimize a remedial engineering design that meets corrective action goals at maximum efficiency and minimum expense.

Page 3: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Landfill groundwater contamination by volatile chlorinated organic compounds (VCOCs) and Freons is pervasive throughout the desert southwest.

As an example of how serious this problem might be, the City of Tucson has concluded, based on a proactive series of extensive remedial investigations, that all of their 40-some unlined or partially-lined landfills have likely contaminated groundwater with VCOCs*.

*R. Murray, City of Tucson, personal communication

Statement of Problem

Page 4: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Conceptual Model of Arid-Landfill Groundwater Contamination by

Volatile Chlorinated Organic Compounds (VCOCs)

Page 5: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

0

25

50

75

100

125

150

175

0 100 200 300 400PCE, ug/l

PCE Beneath Silverbell Landfill, Tucson

Page 6: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

The generally observed distribution of the VCOCs has some interesting characteristics:

1. VCOCs are found up as well as down the groundwater gradient, an observation often interpreted as evidence for an upgradient, non-landfill VCOC source

2. The groundwater plume tends to be depleted in the total organic carbon and semi-volatiles usually associated with landfill leachate. (deprived of electron donors and the resulting anaerobic biodegradation, the VCOC plume will be persistent).

Page 7: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

The generally observed distribution of the VCOCs has some interesting characteristics:

3. The vadose zone (soil gas) concentrations of VCOCS typically increase with depth, suggesting that the source is at depth rather than in the landfill itself

4. The groundwater concentrations of VCOCS are highest at the water table and decrease with depth, implying that the VCOC source is above the water table

Page 8: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

QUESTIONS:

1. Can The Observed Soil and Water VCOC (PCE) Distribution Beneath a Landfill Result From Vapor Phase Movement of PCE Introduced into the Landfill When Active?

2. If So, What is the Most Cost Effective Way to Remove this VCOC Source?

Page 9: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Using Field Data and Numerical Simulation to Evaluate the

Conceptual Model of VCOC Groundwater Contamination

Page 10: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

The Numerical Model and its Assumptions

Model Code: TRAMP (Bentley and Travis, 1989)3-D variably saturated 2-Phase flow and transportuniform steady groundwater flowaerobic/anaerobic biodegradation

VCOC (PCE) initially within Landfill onlyModel parameters derived from site-specific permeabilities, porosities, water content; literature values of PCE anaerobic biodegradation ratesTransport Conditions:Advection resulting from landfill gas generationDiffusion Anaerobic biodegradation of PCE in landfillRun model for 20 years after Silverbell landfill

closure

Page 11: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Roger Rd

Grant Rd

Prince Rd

Flo

win

g W

ells

Rd

Silverbell Rd

N

Plan View of 3-dimensional Model Grid

5000 feet

GROUNDWATER

FLOW DIRECTION

Page 12: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Simulated Silverbell Landfill PCE Movement:

After 2 Years

Water tableDirection of Groundwater flow

Page 13: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Simulated Silverbell Landfill PCE Movement: After 20 Yrs

Water tableDirection of Groundwater flow

Page 14: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Measured and Simulated Silverbell Landfill PCE Concentrations 20 Years

after Closure

0 50 100 150 200 250 300

PC E in ug/l

-180

-160

-140

-120

-100

-80

-60

-40

-20

0

dept

h be

low

land

sur

face

(fe

et)

w ater tab le

sim ulated concentration

m easured soil gas concentration

m easured groundw ater concentration

approxim ate depth of base of landfill

Page 15: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Results of Silverbell Landfill Gas-Phase PCE Transport Simulations

20 years after closure the original source area (the landfill) is relatively free of VCOC while deep vadose soils continue to have relatively high levels of PCE.Gas and liquid advection and diffusion and anaerobic biodegradation are all found to be important in reducing landfill PCE concentrations and increasing concentrations at depth.We conclude that vadose-zone VCOCs beneath the landfill are the source of past and continuing groundwater contamination.

Page 16: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

SVE is clearly the most cost-effective VCOC source removal option

Contamination is deep and covers a large areaVadose soils have a relatively high gas permeabilityContaminants are volatile and therefore amenable to removal by SVE

How best to implement SVE removal of the VCOC source is the rest of this presentation.

Page 17: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Systematic Remediation of Deep Vadose-Zone PCE Contamination

(Harrison Road Landfill, Tucson, Arizona)

Page 18: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Three-Dimensional Model Structure

Harrison Road Landfill, looking southwest

LFG WellsSVI-1: Multi-levelnested probes

SVE-1: Multi-level nested probes

VMW Multi-level nested probes

Base of Landfill

Page 19: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Technical Issues Regarding Sub-Landfill SVE for Removing Deep

VCOCs

Must allow for LFG generation in overlying landfillMust operate in conjunction with LFG collection systemMust minimize air intrusion into landfill to prevent fires and maintain methanogenic efficiencyAn important goal is to minimize number of SVE wells. Cost of an SVE well, at this site, is greater than $50,000

Page 20: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

SVE Design Performance Criteria

Provide early removal of deep vadose VCOC source to groundwaterMinimize drawing VCOCs from shallower soils to deeper soilsMinimize air intrusion into the overlying landfill to maintain the landfill’s anaerobic characterBONUS: Removal of low-volatility organics from any leachate present beneath landfill by means of aerobic biodegradation (bioventing)

Page 21: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Summary of Data Needed for Effective Design of Sub-Landfill SVE

Horizontal and Vertical Soil Air PermeabilityProvide Achievable Subsurface Air

Circulation Rate per SVE WellDetermine Minimum Number of SVE

Wells Needed to Achieve Desired Total Air Circulation Rate.

Ratio of Horizontal to Vertical Air Permeability Affects Surface Leakage and Lateral Effectiveness of Individual SVE Wells

Page 22: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Summary of Data Needed for Effective Design of Sub-Landfill SVE

Subsurface VCOC Distribution Affects Location and Vertical Placement

of SVE wellsSoil Porosity, Moisture Content, Organic Carbon Content and VCOC Properties Affect Calculation of Total VCOC Mass

and Cleanup TimesDistributed Landfill Gas Generation Rates Affect induced SVE flow field

Page 23: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Hydro Geo Chem’s Pneumatic Assessment

ToolboxThe numerical model TRAMP, a powerful 3-D integrated finite difference, distributed parameter model for assessing gas and liquid fate and transport. Includes aerobic and anaerobic biodegradation, thermodynamics, and liquid/gas phase changes. Capable of automatic parameter estimation and design optimization.ASAP, a proprietary pneumatic well test interpretation model. Includes automatic parameter estimation. The Baro-Pneumatic Method, an HGC-patented methodology for assessing landfill gas generation rates and permeabilities. Provides calibration data for numerical (TRAMP) model of landfill gas flow, useful for designing efficient gas collection and control systems.

Page 24: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Obtaining Horizontal and Vertical Gas Permeabilities

Conduct Pneumatic Well TestsInstall wells as part of a trial SVE systemEmploy step-tests to determine well

efficienciesUtilize monitoring wells, if possible, as

observation wells Conduct Baro-pneumatic Tests Monitor barometric pressure and subsurface

pressure responses to changes in barometric pressure. Obtain vertical permeabilities and LFG generation rates

Page 25: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

SVE Wellhead

Construct Monitoring Well that can Later Double as SVE or SVI Well

Page 26: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

APPR O VED D ATE R EFER EN C E FIG U R E

H Y D R OG E OC H E M , I N C .

MEASURED AND SIMULATED DRAW DOW NAT MP-12 DURING PUMPING OF SVE-A4

H :/796000/svetest/svea4/m p12.srf 3TS 2/26/04

Gas Porosity and Horizontal Permeability Estimates by Step-drawdown Test. (ASAP analysis) Gas

extraction well SVE-A4; Observation well MP-12

WELL TEST RESULTS

Pumping well screened 15’-30’Monitoring well screened 15’-17’Wells 24 feet apartGas pumping rates 30, 80 scfmHorizontal permeability 25.1 darciesVertical permeability 0.40 darciesCover permeability = 0.084 darciesGas Porosity = 0.25

Started PumpingAt 30 SCFM

Increased Pumping

to 80 SCFM

Stopped

Pumping

Page 27: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

2700’ AMSL

2530’ AMSL

2630’ AMSL

2550’ AMSL

Kh = 15.0 darcies

Kv = 1.5 darcies

Porosity = 35%

Kh = 15.0 darcies

Kv = 1.5 darcies

Porosity = 35%

Kh = 15.0 darcies

Kv = 1.5 darcies

Porosity = 35%

Kh = 20.0 darcies

Kv = 2.0 darcies

Porosity = 35%

Kh = 150.0 darcies

Kv = 15.0 darcies

Porosity = 45%

Kh = 4.0 darcies

Kv = 4.0 darcies

Porosity = 35%

Kh = 15.0 darcies

Kv = 1.5 darcies

Porosity = 35%

Landfill

Landfill Cap

SVI-1 SVE-1VMW

SVI-1Screen Interval

(203’-283’)

SVI-1Screen Interval

(175’-180’)

SVI-1Screen Interval

(95’-100’)

SVI-1Screen Interval

(135’-140’)

SVI-1Screen Interval

(45’-50’)

SVE-1Screen Interval

75’ -80’

SVE-1Screen Interval

130’ - 135’

SVE-1Screen Interval

150’ - 200’

SVE-1Screen Interval

240’ - 245’

VMW - 1AScreen Interval

(85’ - 90’)

VMW - 1BScreen Interval

(135’ - 140’)

1/14/99

Permeability Distribution for the

Harrison Landfill Model

Note: KH = horizontal permeability KV = vertical permeability

H:\69200\Figures\Permeability Distribution.ppt

Page 28: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

The Baro-Pneumatic Method: Measured Vertical Permeability and LFG Generation Rate at SVI-1,

Harrison Landfill, Tucson

13.20

13.25

13.30

13.35

13.40

0.0 0.5 1.0 1.5 2.0 2.5 3.0Time (days)

Pre

ss

ure

(p

si)

Measured Atmospheric PressureMeasured Pressure 100' BGSModeled Pressure 100' BGS (without LFG)Modeled Pressure 100' BGS (with LFG)

LFG = 740 cfmKv(vertical permeability= 15 darcies (.015 cm/sec)φg (gas porosity) ~ 0.24

Page 29: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

SVE Design Parameters Derived from SVE Performance

Optimization by Numerical Modeling

Need a total of 3 perimeter extraction wells and just one, central air injection well Injection well screened at deeper intervals than extraction wellsInjection wells and extraction wells operate at same rate of flow (250 scfm each.

Page 30: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Simulation of VCOC Remediation Progress

(Month.Year)

SVI

SVE

SVE

SVE

Page 31: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

SVI-1

SVE-1

SVE-2 SVE-3

2000 2500 3000 3500 4000

easting in feet

2000

2500

3000

3500

4000

4500

nort

hing

in fe

et

15102030

SVI-1

SVE-1

SVE-2 SVE-3

2000 2500 3000 3500 4000

easting in feet

2000

2500

3000

3500

4000

4500

nort

hing

in fe

et

PC E in ug/l

S im u la ted V a d o se P C E C o n cen tra tio n s J u st A b o v e th e W a ter T a b le

in itia l conditions after 3 m onths sve operation

Page 32: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

SVI-1

SVE-1

SVE-2 SVE-3

2000 2500 3000 3500 4000

easting in feet

2000

2500

3000

3500

4000

4500

nort

hing

in fe

et

15102030

SVI-1

SVE-1

SVE-2 SVE-3

2000 2500 3000 3500 4000

easting in feet

2000

2500

3000

3500

4000

4500

nort

hing

in fe

et

PC E in ug/l

S im u la ted V a d o se P C E C o n cen tra tio n s J u st A b o v e th e W a ter T a b le

after 3 years sve operationafter 1 year sve operation

Page 33: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Comparing Optimized Harrison Landfill SVE Design Layout to Conventional “Radius of Influence” (ROI) Layout

Based on SVE well tests, and interpretation by our well pneumatics software, ASAP, the achievable SVE pumping rate for each well is 250 standard ft3/min (scfm) and the ROI of each well is 200 feet (at a steady-state vacuum of 0.03 inches H2O).

Setting a well grid at 300 feet between wells provides 25% overlap of the circles defined by a 200-foot ROI. The resulting Harrison Landfill ROI well array is illustrated in the following slide.

Page 34: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

● 200-FOOT ROI WELLS (TOTAL OF 30)

MODEL-OPTIMIZED SVI/SVE WELL LOCATIONS (TOTAL

OF 4)

VCOC-CONTAMINATED VADOSE ZONE

Site-specific and ROI SVE-Well Arrays

Page 35: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Cost Comparison of Optimized Harrison SVE Design to Conventional “Radius of Influence”

(ROI) Design

The SVE well array resulting from the use of a 200-foot ROI is comprised of 30 SVE wells, each costing (in 1999) more than $50,000. Thus the total cost for this conventionally designed system’s well construction exceeds $1.5 million dollars, which compares poorly to the $200,000 well cost for the optimized 4-well system. This estimate does not account for the increased costs associated with valving, sumps, gas collection manifolds, and O&M of the more complex ROI-designed system.

Page 36: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

•Piping (PVC,ABS,Steel, HDPE)•SVE Blower (Lampson spark-proof)•Injection Blower (Roots positive displacement)•Electricity (NEMA4 Enclosures)•Sumps and Off-gas Treatment•Trenching and Cover

SVE Engineering Design

Page 37: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

SVE System Construction

Page 38: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

HDPE Welding

Page 39: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Drainage Crossing Design Details

Page 40: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

1,000 scfm SVE Installation

Page 41: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

0

20

40

60

80

100

120

140

160

180

200

6/1/99 7/2/99 8/2/99 9/2/99 10/3/99 11/3/99 12/4/99

DATE

PC

E C

on

ce

ntr

ati

on

s (

ug

/L)

VMW-2R-150 ft

VMW-2R-200 ft

PCE Reduction in Deep Soils (VMW-2)

Page 42: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

0

10

20

30

40

50

60

70

1/1 1/31 3/2 4/1 5/1 5/31 6/30 7/30 8/29 9/28 10/28 11/27

DATE

To

tal V

OC

Ga

s C

on

ce

ntr

ati

on

s (

ug

/L) VMW-1-90 ft

VMW-1-140 ft

PCE Reduction in Vadose-Zone Soils (VMW-1)

Page 43: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

PCE Reduction in Harrison Rd. Groundwater

(WR-348A)

0.0

0.5

1.0

1.5

2.0

8/8/99 9/7/99 10/7/99 11/6/99 12/6/99DATE

PC

E C

on

cen

trat

ion

(u

g/L

)

Page 44: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Constituent Concentrations

Average Concentration

(8/02)Mass Removed (through 08/02)

(µg/L) (pounds)ALL VOCs 59 17457

NON-FREON VOCs 28 7709 PCE 5.7 2586

Deep Vadose Zone SVE Source Removal

Mass Removed:

Source Removal Completed as of 8/2002; SVE System Shut Down

Deep SVE System Performance at Harrison Landfill

Page 45: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

ConclusionsMost unlined arid-zone landfills have and are contaminating groundwater with VCOCs.Landfill-origin chlorinated VCOCs reach groundwater via gas phase transport.Removal of the landfill origin vadose zone VCOCs sources can be accomplished by SVE.Using pneumatic data collection and SVE simulation to develop the engineering design results in Significant capital and operational cost

savingsHigh collection system efficiency and more

rapid remediation

Page 46: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Suggested Further ReadingCan also be found in: http://www.hgcinc.com/papers.htm

Walter, Gary R. 2002. Fatal Flaws in Measuring Landfill Gas Generation Rates by Empirical Well Testing [PDF] J. Air & Waste Management, 2003 53, p 461Bentley, H.W., S. Smith, J. Tang, and G.R. Walter. 2003. A Method for Estimating the Rate of Landfill Gas Generation by Measurement and Analysis of Barometric Pressure Waves. Proceedings of the 18th International Conference on Solid Waste Technology and Management, Philadelphia, Pennsylvania, March 23-26, 2003 Walter, G.R., Geddis, A.M., Murray, R., Bentley, H.W. 2003. Vapor Phase Transport as a Groundwater Contamination Process at Arid Landfill Sites [PDF]. Proceedings of the 18th International Conference on Solid Waste Technology and Management, Philadelphia, Pennsylvania, March 23-26, 2003 Bentley, H.W., S.J. Smith, and T. Schrauf. 2005. Baro-pneumatic Estimation of Landfill Gas Generation Rates at Four Operating Landfills. Proceedings, SWANA’s 28th Annual Landfill Gas Symposium, March 7-10, 2005 Smith, S.J., H.W. Bentley, and K. Reaves. 2006. Systematic Design of Methane Migration Control Systems. Proceedings, 29th Annual SWANA Landfill Gas Symposium, St. Petersburg FL, March 27-30. 18 pp.

Page 47: HYDRO GEO CHEM INC. by  Systematic Remedial Methodology for Chlorinated VOC Contamination of Soils and Groundwater Underlying Desert Landfills.

HYDROGEOCHEMINC.

Contact Information

Harold W. Bentley, Ph.D.Principal ScientistHydro Geo Chem, Inc.51 W. Wetmore Road

Ste 101Tucson, AZ 85705Phone:  520 293-1500 x 111

Cell:      520 991-5272FAX:      520 293-1550email: [email protected] Website: www.hgcinc.com

Stewart Smith, MS.Associate HydrogeologistHydro Geo Chem, Inc.51 W. Wetmore RoadSte 101Tucson, AZ 85705Phone:  520 293-1500 x 111FAX:      520 293-1550email: [email protected] Website: www.hgcinc.com


Recommended