HYDROGEN RCS:HYDROGEN RCS:REGULATIONS | CODES | STANDARDS
ITM POWER DESIGNSAND MANUFACTURESAND MANUFACTURES
HYDROGEN ENERGY SYSTEMSFOR ENERGY STORAGE AND
CLEAN FUEL PRODUCTIONCLEAN FUEL PRODUCTION
HYDROGEN RCS:HYDROGEN RCS:REGULATIONS | CODES | STANDARDS
Contents
• IntroductionIntroduction• ITM Involvement in RCS• ISO Accreditation• Products and CE marking
ITM POWER DESIGNSAND MANUFACTURESProducts and CE marking
• Hydrogen Refuelling• Hydrogen Purity
AND MANUFACTURESHYDROGEN ENERGY SYSTEMS
FOR ENERGY STORAGE ANDCLEAN FUEL PRODUCTIONCLEAN FUEL PRODUCTION
POSITIONING
HYDROGENENERGY STORAGE
HYDROGEN TRANSPORT FUEL
THE PROBLEM
Electricity cannot be easily stored
• Renewable power cannot be scheduled• Renewable power cannot be scheduled• Supply and demand balancing act• The system needs energy storage• Power to hydrogen is 70% efficient• Power to hydrogen is 70% efficient• Separates Power from Energy• Low Cost Electricity → High Grade Fuel
POSITIONINGPOSITIONINGENERGY STORAGE | CLEAN FUEL
THE SOLUTION
Production of hydrogen controlled by the electricity companies
• Balancing supply and demand • Supports further RE integration• Control shifts to the demand sideControl shifts to the demand side• Switched on/off by the power company• On site fuel production• Protection from rising fuel costsProtection from rising fuel costs
POSITIONINGPOSITIONINGENERGY STORAGE | CLEAN FUEL
A TRIPLE ZERO FUEL
On-site production of hydrogen from renewable power
• Zero carbon in its production• Zero carbon in its transportation• Zero exhaust emissionsZero exhaust emissions
POSITIONINGPOSITIONINGENERGY STORAGE | CLEAN FUEL
COMPLIANCE EXPERIENCE
• ISO accreditation• CE marking of first electrolyser systems• Hydrogen On Site Trials (HOST) for mobile hydrogen refueller
ISO• ISO 9001• ISO 14001
CE Marking• PED• LVD
Compliance• HAZOPS• HSE
Product Standards• BSI PVE 3/8• ISO/TC 197ISO 14001
• ISO 18001LVD
• MD• EMC
HSE• Fire Service• Planning
SO/ C 97• BSI GEL 105• ISO/TC 105
COMPLIANCECOMPLIANCEENERGY STORAGE | CLEAN FUEL
QUALITY
ISO 9001ISO 14001ISO 18001ISO 18001
FROM DESIGN THROUGH TO PRODUCTIONCompliance in the context of a quality system
• Company wide compatibility
• Traceability
• Reproducibility
ISO ACCREDITATIONISO ACCREDITATIONENERGY STORAGE | CLEAN FUEL
INTEGRATED SOFTWARE SYSTEMCompliance in the context of a quality system
• Company wide compatibility
• Traceability
• Reproducibility
CAD
FEA
ISO ACCREDITATIONISO ACCREDITATIONENERGY STORAGE | CLEAN FUEL
CE: STRATEGY AND CURRENT STATUSDocumented evidence of compliance to the relevant directives
• Prioritised HPac CE achieved in January
• HBox and HFlame CE achieved in March
• HFuel compliance is ongoing during HOST
TimescaleCAD BoM Routing Procure PED LVD MD Atex EMC Trials Pricing Channel
HPac Jan‐11
SalesISO CE Marking
HBox Mar‐11HFlame Mar‐11
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
ELECTROLYSERCE MARKINGPEDEMCEMCMDLVDATEXATEX
THE ROUTE TO CE COMPLIANCEEssential to enable sale in the EU (CB is international)
• Mandatory for certain groups of products
• Indicates conformity with essential health & safety requirements
• Requirements are set out in a series of EU Directives
• CE by self-declaration or assessment by Notified Bodies (NoBo’s)
• NoBo involvement for PED is compulsory above category 1
ITM Power’s approach:
• ITM used Gastec at CRE Ltd to establish relevant regulations & Directives
• ITM show conformity with Directives through harmonised standards
• Electrolyser standard ISO 22734-1 not harmonised to EU Directives
• Requires a comprehensive Technical File
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
INITIAL SCREENINGUnderstanding the process and relevant directives
• The initial challenge was identification of the relevant EU Directives
• Gastec at CRE undertook a pre-assessment audit of the prototype systems
• Report generated to identify Directives, routes forward and likely issues
• Retained Gastec as consultant through the whole process
• Utilised experience on a variety of interpretation issues
• Regulatory information now available via the outcome of the HYPER project
PED LVD MD ATEX EMC
HPac Y Y Y Y
HB Y Y Y YHBox Y Y Y Y
HFlame Y Y Y
HFuel Y Y Y Y
CE MARKING
HFuel Y Y Y Y
CE MARKINGENERGY STORAGE | CLEAN FUEL
PRESSURE EQUIPMENT DIRECTIVEDirective 97/23/EC concerning pressure equipment
• Pressure vessel category defined by combination of volume & pressure
• Sound Engineering Practices (voluntary assessment) apply to small systems <25 bar litres
• HPac & HBox contain Category II vessels and so required assessment by Notified Body
• Vessel design assessed to EN 13445 series of unfired pressure vessel standards
• Witnessed pressure tests (including unannounced visits)
• Notified Body – Det Norsk Veritas (DNV)
• Registered for PED in Oslo, local inspectors in Sheffield
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
ELECTROMAGNETIC COMPATIBILITY (EMC)Directive 2004/108/EC relating to electromagnetic compatibility
• Requires specialist equipment & expertise
• Trained two staff and loaned equipment to pre-test prototype systems
• Formal testing undertaken by Notified Body
• Testing stresses power supply and control system with focus on:
• Immunity to electromagnetic interference
• Electromagnetic radiation emissions
• Achieved compliance with more stringent limits set by:
• EN 61000-6-2:2005 “Immunity for industrial environments”
• EN 61000-6-3:2007 “Residential, commercial and light industrial”
• Notified Body –York EMC Services Ltd
• Typically 3 days testing per product
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
MACHINERY & LOW VOLTAGE DIRECTIVESDirective 2005/42/EC (Machinery) & Directive 2006/95/EC (Low Voltage)
• Directives are mutually exclusive – use one or the other
• MD is not applicable in systems with no moving parts
• LVD relates to electrical equipment used within certain voltage limits
• Both are voluntary certificates of conformity and require:
• Electrical system tests
• Evidence of control system operation
• Product risk assessment
• Comprehensive Technical File
• Product manual
• Compliance with EN 60204–1(General electrical safety)
• Notified Body – CCQS UK Ltd
• A very wide ranging Directive
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
ATEX DIRECTIVES (ATEX)Two Directives 94/9/EC (ATEX 95) & 1999/92/EC (ATEX 137)
ATEX 95: equipment intended for use in potentially explosive atmospheres
• Electrolysers / fuel cells would not usually need to conform to ATEX 95
• Requirement to ensure explosive atmospheres do not exist within the product
• No ignition sources is part of the machinery directive
ATEX 137: H&S protection of workers potentially at risk from explosive atmospheres
• Product CE marking is not required to address ATEX 137
• No formalised approval route for hydrogen & fc stationary installation
• Guidance on safe installation generated from the HYPER project
• ATEX Directives do not apply to the domestic environment
• Consultacy given by NoBo’s SIRA and BASEEFA
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
TECHNICAL FILEA location for all product information
• General Description
• List of applicable Directives and standards
• Standards checklists
• Risk Assessment
• Pictures and detailed engineering drawings and calculations
• Test reports and EHSR checklist
• Evidence of compliance with Directives
• Instruction manuals
• Name plate
• List of safety critical parts & evidence of conformity
• Safety data sheets
• Sales literature
• Declaration of conformity
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
DECLARATION OF CONFORMITYA statement of compliance to all relevant Directives
• Lists Directives which product conforms to
• Identifies Notified Bodies and specifics of Directives
• Address of manufacturer – the keeper of technical file
• Description of the equipment
• List of harmonised standards applied
• Signature of responsible person typically a Director
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
CE PROCESS SUMMARYUnderstanding the process
• Screening
• Directives
• NoBo’s
• Accreditation
AccreditationNoBoDirectivesScreening
PED DNV
LVD CCQSGasTec MD CCQS
EMC Y k EMCEMC York EMC
ATEX SIRA
CE MARKINGCE MARKINGENERGY STORAGE | CLEAN FUEL
HOST
THE UK’S LARGEST CROSS SECTOR HYDROGEN TRIALHYDROGEN TRIAL
TRIAL PARTNERS
The UK’s largest cross sector hydrogen trial
• 21 commercial partners• Balanced across 7 industrial sectors• Launched at London Stansted Airport• 8 trials completed to-date• Trials are available for sale.
HOSTHOSTHYDROGEN ON SITE TRIALS
HOST DEMONSTRATION
A mobile hydrogen production and dispensing unit
• Comprises 2 20ft ISO containers• 15-50kg, 350-700bar available
HOST Generation Container• 3 x 5kg/day electrolyser stacks - 15kg• PLC control systems, water purification and
thermal management
HOST Storage ContainerC i• Compression
• Storage at 3 pressures; 250, 350 and 410bar• 60kg max storage
HOSTHOSTHYDROGEN ON SITE TRIALS
COMPLIANCE IS POSSIBLE!Working in an evolving legislative environment
• Ensuring product compliance g p p• Working alongside legislative bodies• Implementing safe working practices• Separation distances (NFPA & BCGA)• Site specific H&S requirements• HFuel requirements addressed for road and sea freight• Vehicle certification (VSO)• Engaging local fire authorities• Engaging local fire authorities
HOSTHOSTHYDROGEN ON SITE TRIALS
RCS FOR HFUEL AND HOSTWorking in an evolving legislative environment
• Well defined regulations for flammable gas systemsg g y• Less defined regulations specific to hydrogen refuelling• Fewer for mobile refuellers• CE not required for demonstration although design with CE in mind
Design Transport Site specific Operation• HAZOP• ATEX (95&137)• HSE (HSL)• ISO 22734
• TPED• ADR• DfT (ADR ex)
• Local H&S• Fire Service• NFPA 2• BCGA CP33
• NFPA2• ISO 20100• ISO 14687
ISO 22734 BCGA CP33
HOSTHOSTHYDROGEN ON SITE TRIALS
KEY STEPS FOR THE HOST PROGRAMWorking in a dynamic legislative environment
• Electrolyser generation system designed with guidance from ISO 22734y g y g g• Compliance with ATEX Workplace Directive (99/92/EC) and UK Health & Safety At Work Act 1974• Storage quantity of H2 ~ 60 kg, so COMAH and UK Hazardous Substances consent not applicable• ADR Notified Body and Dangerous Goods Safety Advisor (DGSA) consulted for road
t t ti f t t i lti t i ff b UK DfTtransportation of storage container, ultimate sign off by UK DfT• HSL consulted on best practice for hydrogen storage • Revolve hydrogen ICE transit vans approval from DfT as Vehicle Special Order (VSO)
HOSTHOSTHYDROGEN ON SITE TRIALS
HOST - SITING REQUIREMENTS21 sites with different requirements but common themes
• Separation distances – key requirement HOSTp y q• Minimum distance from other objects, people or hazards (calculated from pipe ID and system pressure)• NFPA 2 Code directly applicable, legal requirement in US (as opposed to best practice guidance in UK)• UK Health & Safety Laboratories (HSL) invited to review the system on behalf of UK HSE• Details given to local Fire Authorities• Compliance with BCGA CP33• Separation distances combining NFPA and BCGA
HOSTHOSTHYDROGEN ON SITE TRIALS
HYDROGEN
PRODUCTSTANDARDS
UK STANDARDS OVERVIEWBSI | ISO | Working groups
• BSI PVE 3/8: Hydrogeny g• BSI GEL 105: Fuel Cells
UK
BSI PVE 3/8
International
ISO/TC 197BSI PVE 3/8
BSI GEL 105
ISO/TC 197
IEC/TC 105
PRODUCT STANDARDSPRODUCT STANDARDSENERGY STORAGE | CLEAN FUEL
HYDROGEN WORKING GROUPSBSI PVE 3/8: British Standards Committee for Hydrogen technologiesShadows ISO/TC 197
Group Standard
WG 5: ISO 17268 Gaseous hydrogen land vehicle refuelling connection devices
WG 6: ISO 15869 Gaseous hydrogen and hydrogen blends - Land vehicle fuel tanks
WG 8: ISO 22734-2 Hydrogen generators using water electrolysis - Residential applications
WG 11: ISO 20100 Gaseous hydrogen - Fuelling stations
WG 12: ISO 14687-2 Hydrogen Fuel - Product Specification - PEM fuel cell for road vehicles
WG 14: ISO 14687-3 Hydrogen Fuel - Product Specification - PEM fuel cell for stationary appliances
WG 15: ISO 15399 Gaseous hydrogen - Cylinders and tubes for stationary storage
WG 16: ISO/TR 15916 Basic considerations for the safety of hydrogen systems
PRODUCT STANDARDSENERGY STORAGE | CLEAN FUEL
PRODUCT STANDARDS
HYDROGEN PURITY STANDARD ISO 14687Fuel cells require very high purity hydrogen and measurement standards
• In 2008, ITM looked to show conformity with ISO/TS 14687-2y• No UK based testing laboratories able to analyse to limits at that time• Participating in UK’s National Measurement Office funded Project• With NPL, Air Products and UKHFCA• To establish analytical capability• Verify conformity with ISO 14687-2/3
Key Impurities
PRODUCT STANDARDSENERGY STORAGE | CLEAN FUEL
PRODUCT STANDARDS
NEW METHODS FOR HYDROGEN PURITY ANALYSISFuel cells require very high purity hydrogen and measurement standards
• Hydrogen from electrolysis is ‘clean’y g y• Only impurities O2 and H2O • Low cost purification• No need for a Pd filter• Hydrogen cost reduction• First step to certification under ISO 14687
PRODUCT STANDARDSENERGY STORAGE | CLEAN FUEL
PRODUCT STANDARDS
AUTOMOTIVE HYDROGENFUTURE
THE BIG WIN
Clean transport fuel is a very big win
• 350 and 700bar operation350 and 700bar operation• Car | Fleet | Infrastructure• 100kg/day; 260 kg storage• Target the German marketg
HFUEL PRODUCTSHFUEL PRODUCTSFROM TECHNOLOGY TO PRODUCTS
COMPLIANCE IN GERMANY
Moving towards convergence of worldwide standards
• Compliance for HOSTINGCompliance for HOSTING• TUV SUD• Examining federal state differences
PRODUCTSPRODUCTSFROM TECHNOLOGY TO PRODUCTS
COMPLIANCE EXPERIENCE
• ISO accreditation• CE marking of first electrolyser systems• Hydrogen On Site Trials (HOST) for mobile hydrogen refueller
ISO• ISO 9001• ISO 14001
CE Marking• PED• LVD
Compliance• HAZOPS• HSE
Product Standards• BSI PVE 3/8• ISO/TC 197ISO 14001
• ISO 18001LVD
• MD• EMC
HSE• Fire Service• Planning
SO/ C 97• BSI GEL 105• ISO/TC 105
COMPLIANCECOMPLIANCEENERGY STORAGE | CLEAN FUEL
HYDROGEN RCS:HYDROGEN RCS:REGULATIONS | CODES | STANDARDS
Summary
• Adoption of hydrogen is accelerating• Adoption of hydrogen is accelerating• RCS is essential for rapid early adoption• Regulatory authorities need to engage• RCS need Worldwide harmonisation
UNIQUE TECHNOLOGYPRODUCT REVENUESRCS need Worldwide harmonisation
• RCS needs funding
PRODUCT REVENUESRAPIDLY DEVELOPING
GLOBAL MARKETFIRST MOVER ADVANTAGEFIRST MOVER ADVANTAGE