Heater Order no. HYDRONIC B 4 W SC – 12 volt 20 1824 05 00 00 HYDRONIC B 4 W SC – 12 volt 20 1821 05 00 00 as complete package HYDRONIC B 5 W SC – 12 volt 20 1820 05 00 00 HYDRONIC B 5 W SC – 12 volt 20 1823 05 00 00 as complete package Heater Order no. HYDRONIC D 4 W SC – 12 volt 25 2257 05 00 00 HYDRONIC D 4 W SC – 12 volt 25 2221 05 00 00 as complete package HYDRONIC D 5 W SC – 12 volt 25 2219 05 00 00 HYDRONIC D 5 W SC – 12 volt 25 2229 05 00 00 as complete package HYDRONIC Technical description, installation, operation and maintenance instructions. Water heater for diesel and petrol operating independently of the engine.
Transcript
Page 1: Hydronic d5sc Td 06-2007 En

Heater Order no.

HYDRONIC B 4 W SC – 12 volt 20 1824 05 00 00

HYDRONIC B 4 W SC – 12 volt 20 1821 05 00 00as complete package

HYDRONIC B 5 W SC – 12 volt 20 1820 05 00 00

HYDRONIC B 5 W SC – 12 volt 20 1823 05 00 00as complete package

Heater Order no.

HYDRONIC D 4 W SC – 12 volt 25 2257 05 00 00

HYDRONIC D 4 W SC – 12 volt 25 2221 05 00 00as complete package

HYDRONIC D 5 W SC – 12 volt 25 2219 05 00 00

HYDRONIC D 5 W SC – 12 volt 25 2229 05 00 00as complete package

HYDRONICTechnical description, installation,

operation and maintenance instructions.

Water heater for diesel and petroloperating independently of the engine.

Page 2: Hydronic d5sc Td 06-2007 En

2

8

7

6

5

4

3

2

1

Introduction1

Contents

Chapter Title Contents Page

Introduction • Contents ................................................................................................ 2• Concept of this manual ......................................................................... 3• Special text structure, presentation and picture symbols ..................... 4• Important information before starting work ............................................ 4• Statutory regulations ......................................................................... 5, 6• Safety instructions for installation and operation ................................. 7• Accident prevention .............................................................................. 7

Product information • Scope of supply petrol heaters .......................................................... 8, 9• Scope of supply diesel heaters ..................................................... 10, 11• Technical data petrol heaters .............................................................. 12• Technical data diesel heaters .............................................................. 13• Main dimensions .................................................................................. 14

Installation • Installation and location ...................................................................... 15• Possible installation positions ............................................................. 16• Mounting and fastening ....................................................................... 16• Nameplate ........................................................................................... 17• Connection to the cooling water circuit ....................................... 18 – 21• Exhaust system ................................................................................... 22• Combustion air system ........................................................................ 23• Fuel supply petrol heaters ........................................................... 25 – 27• Fuel supply diesel heaters .......................................................... 28 – 30

Operation and • Operating instructions / important information for operation ............... 31function • Initial commissioning ........................................................................... 31

• Description of functions ...................................................................... 31• Control and safety devices ................................................................. 32

Electrical system • Heater wiring ........................................................................................ 33• Parts list for the circuit diagrams .................................................. 33, 34• Circuit diagrams at the end of this manual

Troubleshooting • In case of faults, please check the following points ........................... 35Maintenance • Troubleshooting ................................................................................... 35Service • Maintenance instructions .................................................................... 35

• Service ................................................................................................ 35

Environment • Certification ......................................................................................... 36• Disposal ............................................................................................... 36• EU Declaration of Conformity ............................................................... 36

Lists • List of key words ........................................................................... 37, 38• List of abbreviations ............................................................................ 38

Page 3: Hydronic d5sc Td 06-2007 En

3

Introduction1

Concept of this manual

This manual aims to support the service companyinstalling the heater and to provide the user with allimportant information about the heater.The manual has been divided into 8 chapters to makeit easier to find the corresponding information quickly.

IntroductionHere you will find important introductoryinformation about installation of the heaterand about the structure of the manual.

Product informationHere you will find information about the scopeof supply, the technical data and thedimensions of the heater.

InstallationHere you will find important information andinstructions referring to installation of theheater.

Operation and functionHere you will find information about theoperation and function of the heater.

Electric systemHere you will find information about theelectronic system and electronic componentsof the heater.

Troubleshooting / maintenance / serviceThis section contains information on possiblefaults and malfunctions, troubleshooting,maintenance and the service hotline.

EnvironmentHere you will find information about certificationand disposal of the heater together with the EUDeclaration of Conformity.

ListsHere you will find the key word list andabbreviations list.

2

51

6

7

84

3

Page 4: Hydronic d5sc Td 06-2007 En

4

Special text structure, presentation andpicture symbols

This manual uses special text structures and picturesymbols to emphasise different contents.Please refer to the examples below for thecorresponding meanings and associated actions.

Special structure and presentations

A dot (•) indicates a list which is started by aheading. If an indented dash (–) follows a dot, this listis subordinate to the dot.

Picture symbols

Regulation!This picture symbol with the remark “Regulation”refers to a statutory regulation. Failure to comply withthis regulation results in expiry of the type permit forthe heater and preclusion of any guarantee andliability claims on J. Eberspächer GmbH & Co. KG andits associated companies.

Danger!This picture symbol with the remark “Danger!” refersto the risk of a fatal danger to life and limb. Undercertain circumstances, failure to comply with theseinstructions can result in severe or life-threateninginjuries......

Caution!This picture symbol with the remark “Caution!” refersto a dangerous situation for a person and / or theproduct.Failure to comply with these instructions can result ininjuries to people and / or damage to machinery.

These remarks contain application recommendationsand useful tips for installation of the heater.

Important information beforestarting work

Range of application of the heater

The water heater operating independently of an engineis intended for installation in the following vehicles,depending on its heating output:• Vehicles of all kinds• Construction machinery• Agricultural machinery• Boats, ships and yachts

Installation of the heater is not permitted in vehiclesused for the transport of dangerous goods as perADR / ADR99.

Purpose of the heater(using the vehicle heat exchanger)

• Pre-heating, de-misting windows• Heating and keeping the following warm:

– Driver and working cabs– Freight compartments– Ship’s cabins– Passenger and crew compartments– Vehicle engines and units

On account of its functional purpose, the heater is notpermitted for the following applications:• Long-term continuous operation, e.g. for pre-heating

and heating of:– Residential rooms– Garages– Work huts, weekend homes and hunting huts– Houseboats, etc.

Caution!Safety instructions for application andproper purpose

• The heater must only be used and operated for therange of application stated by the manufacturer incompliance with the “Operating instructions”included with every heater.

Please note!

Please note!

Introduction1

Page 5: Hydronic d5sc Td 06-2007 En

5

Statutory regulations

The Federal Road Transport Directorate has issued an"EC type approval" and an "EMC type approval" for theheater for installation in motor vehicles and with thefollowing official type approval marks, noted on theheater name plate.

HYDRONIC EC- e1 00 0023

EMC- e1 031075

Regulation!Directive 2001 / 56 / EU of the European Parliamentand the Council

• Arrangement of the heater– Parts of the structure and other components near

the heater must be protected from excess heatexposure and possible contamination from fuel oroil.

– The heater must not pose a fire hazard even whenit overheats.This requirement is deemed to be fulfilled whenadequate clearance to all parts is observed duringinstallation, sufficient ventilation is provided andfire-proof materials or heat plates are used.

– The heater must not be located in the passengercompartment in vehicles of class M1, M2, M3 and N.A unit may however be used in a hermetically sealedhousing which also corresponds to the conditionsstated above.

– The factory nameplate or duplicate must be affixedso that it can still be easily read when the heateris installed in the vehicle.

– All appropriate precautions must be taken whenarranging the heater to minimise the risk of injuriesto persons or damage to other property.

• Fuel supply– The fuel intake connection must not be located in

the passenger compartment and must be sealedwith a properly closing lid to prevent any fuel leaks.

– In heaters for liquid fuel where the heater fuel isseparate from the vehicle fuel, the type of fuel andintake connection must be clearly identified.

– A warning sign is to be fixed to the intakeconnection indicating that the heater must beswitched off before refuelling.

• Exhaust system– The exhaust outlet must be arranged so as to

prevent any penetration of exhaust fumes into thevehicle interior through the ventilation system,warm air intakes or open windows.

• Combustion air intake– The air for the heater combustion chamber must

not be sucked in from the passenger compartmentof the vehicle.

– The air intake must be arranged or protected insuch a way that it cannot be blocked by otherobjects.

• Operating status display– A clearly visible operating display in the user’s

field of vision must indicate when the heater isswitched on and off.

Introduction1

Page 6: Hydronic d5sc Td 06-2007 En

6

Please note!

Introduction1

• Compliance with the statutory regulations, theadditional regulations and safety instructions isprerequisite for guarantee and liability claims.Failure to comply with the statutory regulations andsafety instructions and incorrect repairs evenwhen using original spare parts make theguarantee null and void and preclude any liabilityfor J. Eberspächer GmbH & Co. KG.

• Subsequent installation of this heater must complywith these installation instructions.

• The statutory regulations are binding and mustalso

be observed in countries which do not have anyspecial regulations.

• When the heater is to be installed in vehicles notsubject to the German Ordinance for the Regis-tration of Motor Vehicles (StVZO), for exampleships, the specially valid regulations andinstallation instructions for these specialapplications must be observed.

• Installation of the heater in special vehicles mustcomply with the regulations applying to suchvehicles.

• Other installation requirements are contained in thecorresponding sections of this manual.

RegulationsAdditional regulations for certain vehiclesnamed in Directive 94 / 55 / EC (ADRFramework Directive)

ScopeThis appendix applies to vehicles for which the specialprovisions of Directive 94 / 55 / EC apply to combusti-on heaters and their installation.

Definition of terms usedFor the purposes of this appendix, the vehicledesignations "EX / II", "EX / III", "AT", "FL" and "OX"according to Chapter 9.1 of Annex B of Directive 94 /55 / EC are used.

Technical regulations

General provisions (EX / II, EX / III, AT, FL and OXvehicles)

Avoid heating and ignitionThe combustion heaters and their exhaust gas routingshall be designed, located, protected or covered soas to prevent any unacceptable risk of heating orignition of the load. This requirement shall beconsidered as fulfilled if the fuel tank and the exhaustsystem of the appliance conform to provisions in3.1.1.1 and 3.1.1.2. Compliance with theseregulations shall be checked in the complete vehicle.

Fuel tanksFuel tanks for supplying the heater shall conform tothe following regulations:• In the event of any leakage, the fuel shall drain to the

ground without coming into contact with hot parts ofthe vehicle or the load;

• fuel tanks containing petrol shall be equipped with aneffective flame trap at the filler opening or with aclosure enabling the opening to be kept hermeticallysealed.

Exhaust system and exhaust pipe layoutThe exhaust system as well as the exhaust pipes shalllaid out or protected to avoid any danger to the loadthrough heating or ignition. Parts of the exhaustsystem situated directly below the fuel tank (diesel)shall have a clearance of at least 100 mm or beprotected by a thermal shield.

Switching on the combustion heaterThe combustion heater may only be switched onmanually. Automatic switching on via a programmableswitch is not permitted.

EX / II and EX / III vehiclesCombustion heaters for gaseous fuels are not permitted.

FL vehiclesCombustion heaters must be able to be taken out ofservice/disabled at least by the methods described inthe following:a) Switching off manually in the driver's cabinb) Switching off the vehicle's engine; in this case the

heater may be manually switched back on by thevehicle driver;

c) Starting up of a feed pump installed in the vehiclefor the dangerous goods carried.

Combustion heater after-runAfter-running of the switched off combustion heater ispermitted. In the cases named in the "FL vehicles"paragraph under letters b) and c) the supply ofcombustion air must be interrupted by suitable meansafter a maximum after-run period of 40 seconds. Onlycombustion heaters whose heat exchangers areverifiably not damaged by the reduced after-run periodof 40 seconds beyond their usual use period may beused.

Page 7: Hydronic d5sc Td 06-2007 En

7

Safety instructions for installationand operation

Danger!Risk of injury, fire and poisoning• Disconnect the vehicle battery before starting any

kind of work.

• Before working on the heater, switch the heater offand let all hot components cool down.

• The heater must not be operated in enclosed rooms,e.g. in the garage or multi-storey car park.

Caution!Safety instructions for installation and operation• The heater must only be installed by a JE partner

authorised by the manufacturer according to theinstructions in this manual and possibly according tospecial installation recommendations; the sameapplies to any repairs to be carried out in the caseor repairs or guarantee claims.

• Repairs by non-authorised third-parties or with notoriginal spare parts are dangerous and therefore notallowed. They result in expiry of the type permit ofthe heater; consequently, when installed in motorvehicles they can cause expiry of the vehicleoperating licence.

• The following measures are not allowed:– Changes to components relevant to the heater.– Use of third-party components not approved by

J. Eberspächer GmbH & Co. KG.– Nonconformities in installation or operation from

the statutory regulations, safety instructions orspecifications relevant to safe operation as statedin the installation instructions and operatinginstructions. This applies in particular to theelectrical wiring, fuel supply, combustion airsystem and exhaust system.

• Only original accessories and original spare partsmust be used during installation or repairs.

• Only original accessories and original spare partsmust be used during installation or repairs.

• Only the controls approved by Eberspächer may beused to operate the heater.The use of other controls can result in malfunctions.

• Before the heater is installed again in anothervehicle, rinse the heater parts carrying water withclear water.

Introduction1

• When carrying out electric welding on the vehicle,the plus pole cable at the battery should bedisconnected and placed at ground to protect thecontroller.

• The heater must not be operated where there is arisk of an accumulation of flammable vapours ordust, for example close to– fuel depot– coal depot– wood depot– grain depots etc.

• The heater must be switched off when refuelling.

• When the heater is mounted in a safety housingetc., the installation compartment of the heater isnot a stowage compartment and must be kept clear.In particular fuel canisters, oil cans, spray cans,gas cartridges, fire extinguishers, cleaning rags,items of clothing, paper etc. must not be stored ortransported on or next to the heater.

• Defect fuses must only be replaced by fuses withthe prescribed rating.

• If fuel leaks from the heater fuel system, arrangefor the damage to be repaired immediately by aJE service partner.

• When topping up the coolant, only use the coolantpermitted by the vehicle manufacturer, see thevehicle operating manual. Any blending withunpermitted coolant can cause damage to theengine and heater.

• After-running of the heater must not be interruptedprematurely e.g. by pressing the batterydisconnecting switch, apart from in the case of anemergency stop.

Accident prevention

General accident prevention regulations and thecorresponding workshop and operation safetyinstructions are to be observed.

Page 8: Hydronic d5sc Td 06-2007 En

8

Scope of supply for petrol heaters

Quantity / Designation Order number

1 HYDRONIC B 4 W SC – 12 V 20 1824 05 00 00

To be ordered separately:1 Universal installation kit 20 1824 80 00 001 Control unit* –

or

1 HYDRONIC B 4 W SC – 12 V 20 1821 05 00 00as complete package**

To be ordered separately:1 Control unit* –

or

1 HYDRONIC B 5 W SC – 12 V 20 1820 05 00 00

To be ordered separately:1 Universal installation kit 20 1820 80 00 001 Control unit* –

or

1 HYDRONIC B 5 W SC – 12 V 20 1823 05 00 00as complete package**

To be ordered separately:1 Control unit* – Cable harnesses

(A) Cable harness “Controls”

(B) Cable harness “Fan control”

(C) Plus cable

(D) Minus cable

• Parts without picture number are small parts andpacked in a bag.

• Please consult the additional parts catalogue ifany other parts are required for installation.

Parts list for the picture “Scope of supply”on page 9

Scope of supply for petrol heater

Picture No. Designation

1 Heater2 Dosing pump

Scope of supply for universal installation kit

Picture No. Designation

3 Exhaust silencer4 Cable tree, heater5 Cable harness, plus6 Heater bracket7 Water hose8 Flexible exhaust pipe9 Cable tie

10 Bracket, dosing pump11 Pipe, 6 x 212 Combustion air hose13 Hose, 5 x 314 Pipe, 4 x 1

* Control units see price list /accessories catalogue.

** Complete package contains:1 Heater1 Universal installation kit

Product information2

Please note!

Page 9: Hydronic d5sc Td 06-2007 En

9

Scope of supply for petrol heaters

Product information2

Page 10: Hydronic d5sc Td 06-2007 En

10

Scope of supply for diesel heaters

Quantity / Designation Order number

1 HYDRONIC D 4 W SC – 12 V 25 2257 05 00 00

To be ordered separately:1 Universal installation kit 25 2257 80 00 001 Control unit* –

or

1 HYDRONIC D 4 W SC – 12 V 25 2221 05 00 00as complete package**

To be ordered separately:1 Control unit* –

or

1 HYDRONIC D 5 W SC – 12 V 25 2219 05 00 00

To be ordered separately:1 Universal installation kit 25 2219 80 00 001 Control unit* –

or

1 HYDRONIC D 5 W SC – 12 V 25 2229 05 00 00as complete package**

To be ordered separately:1 Control unit* –

Parts list for the picture “Scope of supply”on page 11

Scope of supply for diesel heater

Picture No. Designation

1 Heater

Scope of supply for universal installation kit

Picture No. Designation

2 Exhaust silencer3 Cable tree, heater4 Cable harness, plus5 Heater bracket6 Water hose7 Flexible exhaust pipe8 Cable tie9 Combustion air hose

10 Hose, 3.5 x 311 Pipe, 4 x 1

Cable harnesses

(A) Cable harness “Controls”

(B) Cable harness “Fan control”

(C) Plus cable

(D) Minus cable

• Parts without picture number are small parts andpacked in a bag.

• Please consult the additional parts catalogue ifany other parts are required for installation.

* Control units see price list /accessories catalogue.

** Complete package contains:1 Heater1 Universal installation kit

Please note!

Product information2

Page 11: Hydronic d5sc Td 06-2007 En

11

Scope of supply for diesel heaters

Product information2

Page 12: Hydronic d5sc Td 06-2007 En

12

Technical data for petrol heaters

Heater HYDRONIC B 4 W SC HYDRONIC B 5 W SC

Heating medium Water, cooling fluid

Control of the heat flow Large Small Large Small

Heat flow (watt) 4300 1500 5000 1500

Fuel consumption (l/h) 0.6 0.2 0.69 0.2

Mean electr. power (watt) in operation 48 22 50 22

at start 120

after-running 21

Rated voltage 12 volt

Operating range• Lower voltage limit: An undervoltage protection 10.2 volt

in the controller switches the heater off onreaching approx 10.2 volt.

• Upper voltage limit: An overvoltage protectionin the controller switches the heater off on 16 voltreaching approx 16 volt.

Tolerable operating pressure up to 2.5 bar overpressure

Flow rate of the water pump at 0.1 bar 900 l/h ± 100 l/h

Minimum water flow rate of the heater 250 l/h

Fuel – see also “fuel quality petrol heaters” page 30 Commercially available petrol(DIN EN 228)

Tolerable operating temperature Operation –40 °C to +80 °C

Storage –40 °C to +105 °C

Interference suppression class 5 for VHF, SW, MW2 for LW

Weight without dosing water and add on pieces approx. 2.7 kg

Caution!Safety instructions for technical data!Failure to comply with the technical datacan result in malfunctions. All technical data ±10 %

Product information2

Page 13: Hydronic d5sc Td 06-2007 En

13

Technical data for diesel heaters

Heater HYDRONIC D 4 W SC HYDRONIC D 5 W SC

Heating medium Water, cooling fluid

Control of the heat flow Large Small Large Small

Heat flow (watt) 4300 2400 5000 2400

Fuel consumption (l/h) 0.53 0.27 0.62 0.27

Mean electr. power (watt) in operation 48 23 50 23

at start 120

after-running 21

Rated voltage 12 volt

Operating range• Lower voltage limit: An undervoltage protection 10.2 volt

in the controller switches the heater off onreaching approx 10.2 volt.

• Upper voltage limit: An overvoltage protectionin the controller switches the heater off on 16 voltreaching approx 16 volt.

Tolerable operating pressure up to 2.5 bar overpressure

Flow rate of the water pump at 0.1 bar 900 l/h ± 100 l/h

Minimum water flow rate of the heater 250 l/h

Fuel – see also “fuel quality diesel heaters” page 30 Commercially available diesel(DIN EN 590)

Tolerable operating temperature Operation –40 °C to +80 °C

Storage –40 °C to +105 °C

Interference suppression class 5 for VHF, SW, MW2 for LW

Weight without dosing water and add on pieces approx. 2.9 kg

All technical data ±10 %

Caution!Safety instructions for technical data!Failure to comply with the technical datacan result in malfunctions.

Product information2

Page 14: Hydronic d5sc Td 06-2007 En

14

Main dimensions petrol heater

Main dimensions diesel heater

Product information2

Page 15: Hydronic d5sc Td 06-2007 En

15

Installation location

The installation location for the heater is the enginecompartment. The heater must be mounted below themin. cooling water level (compensation tank, cooler,vehicle heat exchanger) for automatic venting of theheat exchanger of the heater and the water pump.

• The regulations and safety instructions to beobserved for this chapter are stated on page 4 – 7.

• The installation suggestions made in theinstallation instructions are examples. Otherinstallation locations are possible if theycorrespond to the installation requirements statedin these installation instructions.

• Other installation information (e.g. for boats and ships)is available from the manufacturer on request.

• Observe the tolerable installation position togetherwith the operating an storage temperatures.

Installation3

Installation examplefor petrol heater in a car

� Heater� Exhaust pipe with exhaust silencer� Combustion air intake silencer� Fan relay� Fuse bracket� Mini timer� Dosing pump Rising pipe

Installation examplefor diesel heater in a delivery van and a car

� Heater� Exhaust pipe with exhaust silencer� Combustion air intake silencer� Fan relay

� Fuse bracket� Mini timermini timer� Rising pipe T-piece for fuel

Please note!

Page 16: Hydronic d5sc Td 06-2007 En

16

� Vent screw: must always be at the top� Fuel connection

Possible installation positions

The heater should preferably be installed in the normalposition, horizontal with the exhaust connection downto the bottom.Depending on the installation conditions, the heatercan also be mounted in the permitted swivel range,see diagram.

Normal position with permitted swivel range

When the heater is operating, the shown normal ormaximum installation positions can be varied brieflyby up to +15° in all directions. Such deviationscaused by the inclined position of the vehicle do notimpair the heater functions in any way.

• Swivel range from the normal position to max. 90°swivelled around the longitudinal axis: the waterconnections are horizontal.

• Swivel range from the normal position swivelleddown to max. 90°: the water connections pointdownwards.

Mounting and fastening

Position the heater in the holding clips of the heaterbracket and fasten with fastening screw, M6 x 97(tightening torque 6+0.5Nm). Mount the heater bracketin a suitable position in the engine compartment,possibly using anti-vibration pads if necessary.

Depending on the installation space available, theheater can be moved sideways in the bracket andscrewed in one of the two fastening threads.

� Heater� Bracket clips� Bracket holder� Fastening screw� Fastening thread

Installation3

Please note!

Page 17: Hydronic d5sc Td 06-2007 En

17

Nameplate

The nameplate is fastened to the front of the heater.The second nameplate (duplicate) is included in thescope of supply of the heater.If required, the duplicate nameplate can be adheredin a clearly visible position on the heater or near tothe heater.

The regulations and safety instructions to beobserved for this chapter are stated on page 5.

� Original nameplate� 2nd nameplate (duplicate)

Installation3

Please note!

Page 18: Hydronic d5sc Td 06-2007 En

18

Connection to the cooling water circuit

The heater is connected to the cooling water circuitin the water feed pipe from the vehicle engine to theheat exchanger. There are four possible alternativeinstallations here.

The alternatives are described on pages 19 – 21.

Danger!Risk of injuries and burns!

It is possible for the coolant and components of thecoolant circuit to get very hot.

• Parts conveying water must be routed and fastenedin such a way that they pose no temperature risk toman, animals or material sensitive to temperaturefrom radiation / direct contact.

• Before working on the coolant circuit, switch theheater off and wait until all components have cooleddown completely, if necessary where safety gloves.

• When installing the heater, please take note of thedirection of flow of the coolant circuit.

• Fill the heater and water hoses with coolant beforeconnecting to the coolant circuit.

• Route the water hoses without any kinks, and in arising position if possible.

• When routing the water pipes, observe a sufficientclearance to hot vehicle parts.

• Protect all water hoses / water pipes from chafingand from extreme temperatures.

• Secure all hose connections with hose clips(tightening torque = 1.5Nm).

• After the vehicle has been operating for 2 hours ortravelled 100 km, tighten the hose clips again.

• The minimum water flow rate is only guaranteed ifthe temperature difference of the heating mediumdoes not exceed 10 K between water inlet and wateroutlet during heating.

• Only overpressure valves with an opening pressureof min. 0.4 – max. 2 bar may be used in the coolantcircuit.

• The coolant liquid must contain at least 10 %antifreeze all year round as corrosion protection.

• The cooling liquid must contain sufficient antifreezefor low temperatures.

• Before commissioning the heater or after changingthe cooling liquid, the whole coolant circuit includingheater must be vented free of bubbles according tothe instructions issued by the vehicle manufacturer.

• Only top up with coolant approved by the vehiclemanufacturer.

Please note!

Installation3

Page 19: Hydronic d5sc Td 06-2007 En

19

Heating characteristics

When the heater is switched on, the heat flows throughthe vehicle heat exchanger and the vehicle engine.Once the cooling water has reached a temperature ofapprox. 30 °C, depending on the selected fan settingthe vehicle fan is switched on and the heat is alsoconveyed to the passenger compartment.

Connection to the cooling water circuit

Integrate the heater in the water feed pipe fromthe vehicle engine to the heat exchanger “inlineconnection”

Disconnect the water feed pipe from the vehicle engineto the vehicle heat exchanger. Connect up the heaterwith connection pieces and water hoses to the waterfeed pipe.

� Heater� Connection piece� Heat exchanger� Vehicle engine

Integrate the heater in the cooling water circuitwith a non-return valve

Disconnect the water feed pipe from the vehicleengine to the vehicle heat exchanger and insert thenon-return valve. Connect up the heater to the non-return valve using the water hoses.

Heating characteristics

When the heater is switched on, the heat flows throughthe vehicle heat exchanger only to the vehicle engine.Once the cooling water has reached a temperature ofapprox. 30 °C, depending on the selected fan settingthe vehicle fan is switched on and the heat is alsoconveyed to the passenger compartment.

Advantage compared to “inline connection”cooling water circuitNo loss of efficiency in the vehicle heating when theheater is switched off.

� Heater� Non-return valve� Heat exchanger� Vehicle engine

� �

Installation3

Page 20: Hydronic d5sc Td 06-2007 En

20

Heating characteristics

Small coolant circuitFast heating of the passenger compartment. Initiallythe heat produced by the heater is only conveyed tothe heat exchanger up to a cooling water temperatureof approx. 70 °C. This heats the passengercompartment up quickly.Large cooling water circuitIf the cooling water temperature continues to increase,the thermostat slowly changes over to the large circuit(full change-over at approx. 75 °C). This heats thepassenger compartment up and also allows for enginepre-heating.

Connection to the cooling water circuit

Integrate the heater in the cooling water circuitwith a non-return valve, thermostat and T-piece(for HYDRONIC B 5 W SC / D 5 W SC only)

Disconnect the water feed pipe from the vehicleengine to the vehicle heat exchanger and insertthe non-return valve.Disconnect the water return pipe from the heatexchanger to the vehicle engine and insert theT-piece.Connect the heater and thermostat with water hosesto the non-return vale and T-piece as shown in thediagram.

� Heater� Non-return valve� Thermostat� T-piece� Heat exchanger� Vehicle engine

Thermostat functions

Cooling water temperature < 70 °C –small coolant circuit:Connection no. 1 – open to the heaterConnection no. 2 – open to the T-pieceConnection no. 3 – closed to the non-return valve

Cooling water temperature > 75 °C –large coolant circuit:Connection no. 1 – open (to the heater)Connection no. 2 – closed (to the T-piece)Connection no. 3 – open (to the non-return valve)

Integrate the thermostat into the water circuit withconnections � � and � as shown in the diagram.

� Connection to the heater� Connection to the T-piece� Connection to the non-return valve

Thermostat, non-return valve and T-piece arecontained in the convenient installation kit. Order no.see extra parts catalogue.

Please note!

Please note!

Installation3

Page 21: Hydronic d5sc Td 06-2007 En

21

Heating characteristics

Pre-heating mode – small coolant circuitFor the pre-heating mode, the heat is conveyed onlyto the vehicle heat exchanger so that the passengercompartment heats up quickly.

Extra heating function – partial circuitWhen the vehicle engine starts up – low speed – partof the heat is conveyed to the vehicle engine.Shortens the warming up phase for the engine andheats the passenger compartment.

Extra heating function – large coolant circuitAt higher engine speeds (approx. 200 rpm), the heatis distributed evenly between the heat exchanger andthe vehicle engine. Shortens the warming up phaseeven further and heats the passenger compartment.

Connection to the coolant circuit

Integrate heater in coolant circuit with thecombination valve

Combination valve with 5 connections

If the water feed pipe and water return pipe from thevehicle engine to the heat exchanger are installedseparately, the combination valve with 5 connectionsand an additional T-piece has to be used.

Combination valve with 6 connections

If the water feed pipe and water return pipe from thevehicle engine to the heat exchanger are installed inparallel, the combination valve with 6 connections(without T-piece) can be used.

Install combination valve with 5 connections

Disconnect the water feed pipe from the vehicle engineto the vehicle heat exchanger and insert the combinationvalve.Disconnect the water return pipe from the heat exchangerto the vehicle engine and insert the T-piece.Connect the heater to the combination valve and T-piecewith the water hoses, as shown in the drawing.

� Heater� Combination valve

(5 connections)� T-piece� Heat exchanger� Vehicle engine

Install combination valve with 6 connections

Disconnect the water feed pipe and the water returnpipe from the vehicle engine to the vehicle heatexchanger and insert the combination valve.Connect the heater to the combination valve with thewater hoses, as shown in the drawing.

Combination valve (6 connections)HYDRONIC

fromvehicle engine

tovehicle engine

tovehicle heat exchanger

fromvehicle exchanger

Installation3

Page 22: Hydronic d5sc Td 06-2007 En

22

Exhaust system(Exhaust diagram see page 23)

Mounting the exhaust system

The scope of supply of the universal installation kitincludes a flexible exhaust pipe, inner Ø 24 mm,1000 mm long and an exhaust silencer.The flexible exhaust pipe can be shortened to 20 cmor lengthened to max. 2 m, depending on theinstallation conditions.Fasten the exhaust silencer to a suitable position inthe vehicle. Route the flexible exhaust pipe from theheater to the exhaust silencer and fasten with pipeclips. If necessary, also fasten the flexible exhaustpipe with pipe clips at suitable positions in the vehicle.Connect the exhaust end pipe to the exhaust silencerwith an end sleeve and fasten with a pipe clip.

Caution!Safety instructions!The whole exhaust system gets very hot during andimmediately after the heater has been working in theheating mode. This is why the exhaust system mustbe routed according to these installation instructions.• The exhaust outlet must end in the open air.• The exhaust pipe must not protrude beyond the

lateral limits of the vehicle.• Install the exhaust pipe sloping slightly downwards.

If necessary, make a drain hole approx. Ø 5 mm atthe lowest point to drain off condensation.

• Important functional parts of the vehicle must not beimpaired (keep sufficient clearance).

• Mount the exhaust pipe with sufficient clearance toheat-sensitive parts. Pay particular attention to fuelpipes (plastic or metal), electrical cables and brakehoses etc.!

• Exhaust pipes must be fastened safely(recommended clearance of 50 cm) to avoid damagefrom vibrations.

• Route the exhaust system so that the emitted fumesare not sucked in with the combustion air.

• The mouth of the exhaust pipe must not get cloggedby dirt and snow.

• The mouth of the exhaust pipe must not point in thedirection of travel.

• Always fasten the exhaust silencer to the vehicle.

Danger!Risk of injuries and burns!Every type of combustion produces high temperaturesand toxic exhaust fumes. This is the reason why theexhaust system must be installed according to theseinstructions.• Do not perform any work on the exhaust system

while the heater is working.• Before working on the exhaust system, first switch

the heater off and wait until all parts have cooleddown completely, wear safety gloves if necessary.

• Do not inhale exhaust fumes.

• Comply with the regulations and safety instructionsfor this chapter on page 4 – 7.

• If a silencer is fitted, the exhaust end pipe mustbe much shorter than the flexible exhaust pipebetween the heater and the exhaust silencer.

Please note!

Installation3

Page 23: Hydronic d5sc Td 06-2007 En

23

� Heater� Combustion air pipe� Exhaust pipe� Exhaust silencer� Exhaust end pipe

Caution!Safety instructions for the combustion air system• The combustion air opening must be free at all

times.• Position the combustion air intake to be sure that

exhaust fumes cannot be sucked in with thecombustion air.

• Do not arrange the combustion air intake topointing against the wind blast.

• The combustion air intake must not get cloggedwith dirt and snow.

• Install the combustion air intake system slopingslightly downwards. If necessary, make a drainhole approx. Ø 5 mm at the lowest point to drainoff condensation.

Combustion air system

Mounting the combustion air system

The heater is mounted in the engine compartment, asdescribed in these instructions.If the intake connection for combustion air is in aposition where the combustion air can be expected tobe no warmer than 25 °C and whether neithersplashed water nor dust/dirt are expected, then nocombustion air hose is required.Otherwise a flexible combustion hose must bemounted with an inner Ø 20 mm and up to 1.5 m long,to ensure that the intake of combustion air comesfrom an area which complies with the aboveconditions.After completing all work, push an end sleeve overthe intake silencer / flexible pipe.

Comply with the regulations and safety instructionsfor this chapter on page 4 – 7.

Please note!

min. 20 cmmax. 1.5 m to max. 2 m

Installation3

Page 24: Hydronic d5sc Td 06-2007 En

24

Fuel supply

Mounting the dosing pump, routing the fuel pipesand mounting the fuel tank

The following safety instructions must be observedwhen mounting the dosing pump, routing the fuel pipesand mounting the fuel tank.Deviations from the instructions stated here are notallowed.Failure to comply can result in malfunctions.

Danger!Risk of fire, explosion, poisoning and injuries!

Caution when handling fuel.

• Switch off the vehicle engine and heater beforerefuelling and before working on the fuel supply.

• No naked lights when handling fuel.

• Do not smoke.

• Do not inhale fuel vapours.

• Avoid any contact with the skin.

Caution!Safety instructions for routing the fuel pipes!

• Only use a sharp knife to cut off fuel hoses andpipes. Interfaces must not be crushed and must befree of burrs.

• The fuel pipe from the dosing pump to the heatershould be routed at a continuous rise.

• Fuel pipes must be fastened safely to avoid anydamage and / or noise production from vibrations(recommended clearance of approx. 50 cm).

• Fuel pipes must be protected from any mechanicaldamage.

• Route the fuel pipes so that any distortion of thevehicle, engine movements etc. cannot have anylasting effect on the service life.

• Parts carrying fuel must be protected frominterfering heat.

• Never route or fasten the fuel pipes to the heater orvehicle exhaust system. When the systems cross,always ensure there is a sufficient heat clearance.If necessary, install heat deflection plates.

• Dripping or evaporating fuel must never be allowedto collect on hot parts or ignite on electric systems.

• When connecting fuel pipes with a fuel hose, alwaysmount the fuel pipes in a butt joint to prevent anybubbles from forming.

Safety instructions for fuel pipes and fuel tanksin buses and coaches

• In buses and coaches, fuel pipes and fuel tanksmust not be routed through the passengercompartment or driver’s cab.

• Fuel tanks in buses and coaches must bepositioned in such a way that the exits are not indirect danger from a possible fire.

Comply with the regulations and safety instructionsfor this chapter on page 4 – 7.

Please note!

� Correct connection� Incorrect connection – bubble formation

� �

Installation3

Page 25: Hydronic d5sc Td 06-2007 En

25

Fuel feed point with T-piece from the fuel supply linefrom the tank fitting to the vehicle engine

� Fuel feed pipe from tank connection – insertT-piece before the fuel pump in the fuel feed pipe.

� Fuel return pipe to the tank connection� Dosing pump� T-piece, 8-6-8� Fuel filter – only necessary for contaminated fuel.� Fuel hose, 5 x 3 (di = Ø 5 mm)� Fuel pipe, 6 x 2 (di = Ø 2 mm) Fuel pipe, 4 x 1.25 (di = Ø 1.5 mm) Fuel hose, 5 x 3 (di = Ø 5 mm),

approx. 50 mm long� Fuel hose, 3.5 x 3 (di = Ø 3.5 mm),

approx. 50 mm long� To the engine, mechanical fuel or injection pump.

Possible pipe lengths

Intake side Pressure sidea = max. 2 m b = max. 4 m

Fuel supply for petrol heaters

Items � and � are not included in the scopeof supply “installation kit”.Order no. see extra parts catalogue.

Please note!

Installation position of the T-piece

Use the installation positions shown in the diagramwhen inserting a T-piece.

� Direction of flow from the fuel tank� Direction of flow to the vehicle engine

� �

Installation3

Page 26: Hydronic d5sc Td 06-2007 En

26

Fuel feed point with tank connection –ascending pipe, integrated in the vehicle tank

� Tank connection for metal tank –di = Ø 2 mm, da = Ø 6 mm

� Tank connection for tank fitting –di = Ø 2 mm, da = Ø 4 mm

� Dosing pump� Fuel filter – only required for contaminated fuel.� Fuel hose, 5 x 3 (di = Ø 5 mm)� Fuel pipe, 6 x 2 (di = Ø 2 mm)� Fuel hose, 4 x 1 (di = Ø 2 mm) Fuel hose, 3.5 x 3 (di = Ø 3.5 mm),

approx. 50 mm long Fuel hose, 5 x 3 (di = Ø 5 mm),

approx. 50 mm long� Fuel pipe, 4 x 1.25 (di = Ø 1.5 mm)� Connection fitting, da = Ø 4 mm

Possible pipe lengths

Intake side Pressure sidea = max. 2 m b = max. 4 m

Items � � � are included in the “tank connection “ kit.

Fuel supply for petrol heaters

Caution!Safety instructions for the fuel supply!

• The fuel must not be conveyed by gravity oroverpressure in the fuel tank.

• Withdrawal of fuel after the vehicle’s fuel pump isnot allowed.

• When the pressure in the fuel pipe is more than0.2 bar to max. 2 bar, use a pressure reducer(order no. 22 1000 20 08 00) or separate tankconnection.

• When the pressure in the fuel pipe is more than2 bar or there is a non-return valve in the return pipe(in the tank), a separate tank connection must beused.

• When using a T-piece in a plastic pipe, always usesupport sleeves in the plastic. Connect the T-pieceand the plastic pipe with corresponding fuel hosesand secure with hose clips.

Please note!

Installation3

Page 27: Hydronic d5sc Td 06-2007 En

27

Possible suction and pressure heightof the dosing pump

Pressure height from vehicle tank to dosing pump:a = max. 3000 mm

Intake height in pressure-less vehicle tank:b = max. 500 mm

Intake height in vehicle tanks with withdrawal bynegative pressure (valve with 0.03 bar in tank cap):b = max. 150 mm

Pressure height of the dosing pump to the heater:c = max. 2000 mm

Check tank venting.� Connection to heater� Max. fuel level� Min. fuel level

Fuel supply for petrol heaters

Installation position of the dosing pump

Always mount the dosing pump with the pressure siderising upwards. Every installation position over 15° isallowed, although an installation position between 15°and 35° is preferable.

� Installation position between 0° and 15°is not allowed.

� Preferred installation position in range 15° to 35°.� Installation position in range 35° to 90° is

allowed.

Caution!Safety instructions for installingthe dosing pump• Always mount the dosing pump with the pressure

side rising upwards – minimum incline 15°.

• Protect the dosing pump and filter from intolerableheat, do not mount near to the silencers andexhaust pipes.

Please note!

Installation3

Page 28: Hydronic d5sc Td 06-2007 En

28

Fuel feed point with T-piece from the fuel supplyline from the tank fitting to the vehicle engine.

� Fuel return pipe from the tank connection� Fuel feed pipe from tank connection – insert

T-piece before the fuel pump in the fuel feed pipe.� T-piece� Fuel hose, 3.5 x 3 (di = Ø 3.5 mm)

approx. 50 mm long� Fuel filter – only necessary for contaminated fuel.� Fuel pipe, 4 x 1 (di = Ø 2 mm)� To the engine, mechanical fuel or injection pump.

Possible pipe lengths

Intake sidea = max. 5 m

Fuel supply for diesel heaters

Installation position of the T-piece

Use the installation positions shown in the diagramwhen inserting a T-piece.

� Direction of flow from the fuel tank� Direction of flow to the vehicle engine

� �

Installation3

Page 29: Hydronic d5sc Td 06-2007 En

29

Fuel feed point with ascending pipe in the tank connection,integrated in the vehicle tank or in the tank fitting

� Tank connection for tank fitting,di = Ø 2 mm, da = Ø 4 mm

� Fuel hose, 3.5 x 3 (di = Ø 3.5 mm),approx. 50 mm long

� Fuel filter – only necessary for contaminated fuel.� Fuel pipe, 4 x 1 (di = Ø 2 mm)

Possible pipe length:

Intake side:a = max. 5 m

Fuel supply for diesel heaters

� Connection to heater� Max. fuel level� Min. fuel level

Possible intake and pressure height:

Pressure height from vehicle tank to heater:a = max. 3000 mm

Suction height for pressure-free vehicle tank:b = max. 1000 mm

Suction height for a vehicle tank with withdrawal undernegative pressure (valve with 0.03 bar in tank cap):b = max. 400 mm

Check tank venting.

Please note!

Installation3

Page 30: Hydronic d5sc Td 06-2007 En

30

Installation3

Fuel supply

Fuel quality for petrol heatersThe heater can run on commercially available fuelas per DIN EN 228, as used in the vehicle tank.

Fuel quality for diesel heatersThe heater can run on commercially available dieselfuel as per DIN EN 590 as used in the vehicle tank.

Fuel for special casesIn special cases (above 0 °C), the heater can also runon fuel oil EL or paraffin.

Fuel for low temperaturesRefineries and fuel service stations automaticallyadjust the fuel to normal winter temperatures (winterdiesel). This means that difficulties are only to beexpected for extreme drops in temperature, as alsoapply to the vehicle engine. Please also refer to thevehicle manual.

If the heater is run from a separate tank, pleasecomply with the following rules:For temperatures above 0 °C, any kind of diesel fuelas per DIN EN 590 can be used.

If no special diesel fuel is available for lowtemperatures, then paraffin or petrol should be mixedwith the fuel according to the following table:

Temperature Winterdiesel Addition 0 °C to –25 °C 100 % ––25 °C to –40 °C 50 %* 50 % paraffin

or petrol

* or 100 % special cold diesel fuel (Arctic diesel)

• Mixtures with used oil are not allowed!

• After refuelling with winter or cold diesel or the listedblends, the fuel pipes and the dosing pump must befilled with the new fuel by letting the heater run for15 mins.!

Operation with biodiesel (PME)The heater is not certified for operation with biodiesel.

Please note!

Page 31: Hydronic d5sc Td 06-2007 En

31

Operating instructions

The heater is operated by a control unit.The control unit is accompanied by detailed operatinginstructions which you will receive from the companyinstalling the heater.

The control units (e.g. mini timer, module timer) aresupplied accompanied with operating instructionswhich will be handed over to you by the companyinstalling the heater).

Important instructions for operation

Safety checks before the startAfter a longer interval in operations (after the summermonths) the fuse must be put in position and / or theheater connected up to the battery. Check that allparts fit firmly (tighten screws where necessary).Check the fuel system visually for any leaks.

Before switching onBefore switching on or pre-programming the heater,adjust the heating control in the vehicle to “WARM”(maximum setting) and the fan to “SLOW” (low powerconsumption).In vehicles with automatic heating, adjust the heatingcontrol to “MAX” and open the heating vents beforeswitching the ignition off.

Pre-venting with change-over “heating / venting”Pre-venting means the possibility of starting thevehicle fan directly from the heater preselection timeror, even more convenient, from the radio remotecontrol TP4i or TP41i, thus bypassing the heatingmode, so that the passenger compartment, whichfrequently heats up considerably in summer weather,can be ventilated briefly with fresh air (separatewiring).

Heating at high altitudesWhen using the heater at high altitudes, please note:

• Heating at altitudes up to 1500 m:– Unlimited heating possible.

• Heating at altitudes over 1500 mm:– Heating is possible for short periods at this

altitude (e.g. driving over a mountain pass ortaking a break in a journey).

– In the event of a lengthy stay, e.g. wintercamping, it is necessary to adjust the fuel supplyto the altitude, please contact a JE partner forfurther information.

In diesel heaters, 12 volt, it is possible to install analtitude pump kit (Order No.: 24 0244 00 00 00),which allows the heater to be run at altitudes over1500 m and up to 2750 m, even during a lengthy stay.

Operation and function4

Initial commissioning

The following points are to be checked by thecompany installing the heater during initialcommissioning.

• After installation of the heater, the coolant circuitand the whole fuel supply system must be ventedcarefully. Comply with the instructions issued by thevehicle manufacturer.

• Open the coolant circuit before the trial run (se thetemperature control to “WARM”).

• During the trial run of the heater, check all water andfuel connections for leaks and firm fitting.

• If the heater shows a fault during operation, findand eliminate the cause of the fault using adiagnosis unit.

Description of functions

Switching on (pre-heating mode)When the heater is switched on, the control lamp inthe control unit (mini-timer, module timer) lights up.The water pump and the combustion air fan start up.After a certain programme with pre-rinsing and pre-heating, the glow plug and fuel dosing pump start thecombustion procedure. Once a stable flame hasformed, the glow plug switches off under time control.

Heating modeDepending on heating requirements, the heater isadjusted in the following stages:LARGE – SMALL – OFF (pause).The temperature limits are permanently programmed inthe electronic controller.If the heating requirements in the “SMALL” stage areso small that the cooling water temperature reaches85°C, the heater goes into the pause mode.The heater continues to run on for approx. 130seconds, then it switches off (pause mode).The control lamp lights up and the water pumpcontinues to run, even in the pause mode.

To compensate for the low heating requirementscoming from the vehicle engine, the heater can beoperated as pre-heater or combined pre-heater andextra heater, depending on the settings (wiring seecircuit diagram).

Please note!

Please note!

Please note!

Page 32: Hydronic d5sc Td 06-2007 En

32

Operation and function4

Control and safety devices

• If the heater does not ignite within 90 secondsafter starting the fuel pump, the start is repeated.If the heater still does not ignite after another90 seconds, the heater is switched off. After anunacceptable number of failed start attempts, thecontroller is locked.*

• If the flame goes off by itself during operation, theheater is restarted.If the heater does not ignite within 90 secondsafter the fuel pump has started again, or it ignitesbut goes off again within 15 minutes, the heater isswitched off.This status can be remedied by briefly switchingoff and on again.

• In the case of overheating (e.g. lack of water,poorly vented coolant circuit), the overheatingsensor triggers, the fuel supply is interrupted andthe heater switched off.Once the cause of overheating has beeneliminated, the heater can be re-started byswitching off and on again (on condition that theheater has cooled down again sufficiently, coolingwater temperature < 70 °C).After the heater has been switched off foroverheating an unacceptable number of times,the controller is locked.*

• The heater is switched off if the upper or lowervoltage limit is reached.

• The heater does not start up when the glow plug isdefect or when the electric lead to the dosing pumpis interrupted.

• The speed of the fan motor is monitoredcontinuously.If the fan motor does not start up, if it is blockedor if the speed falls below 40 % of the nominalspeed, the heater is switched off after 60 sec.

* The controller can be enabled again and the faultsread off:• using the module timer• using the radio remote control TP5.For other controls:• by connecting up a diagnosis unit• using the customer service program KD 2000.For operation and fault list, please refer to theenclosed operating instructions or thetroubleshooting and repair instructions for theheater.

Do not switch the heater off and on again more thantwice.

Emergency shutdown – EMERGENCY OFFIf an emergency shutdown – EMERGENCY OFF –is necessary during operation, proceed as follows:• Switch the heater off with the control or• pull the fuse out or• disconnect the heater from the battery.

Please note!

Page 33: Hydronic d5sc Td 06-2007 En

33

Heater wiring

Caution!Safety instructions for wiring the heater!The heater is to be connected up electricallyaccording to the EMC directives.EMC can be affected if the heater is not connected upcorrectly. For this reason, comply with the followinginstructions:

• Ensure that the insulation of electrical cables is notdamaged. Avoid: chafing, kinking, jamming orexposure to heat.

• In waterproof connectors, seal any connectorchambers not in use with filler plugs to ensure theyare dirt-proof and water-proof.

• Electrical connections and ground connections mustbe free of corrosion and firmly connected.

• Lubricate connections and ground connectionsoutside the heater interior with contact grease.

Comply with the following when wiring the heater and thecontrol element:

• Electrical leads, switchgear and controllers must bearranged in the vehicle so that they can functionperfectly under normal operating conditions(e.g.heat exposure, moisture etc.).

• The following cable cross sections are to be usedbetween the battery and heater. This ensures thatthe max. tolerable voltage loss in the cables doesnot exceed 0.5 V for 12 V or 1 V for 24 V ratedvoltage.Cable cross sections for a cable length of:– up to 5 m (plus cable + minus cable) = cable cross section 4 mm²– from 5 to 8 m (plus cable + minus cable) = cable cross section 6 mm²

• If the plus cable is to be connected to the fuse box(e.g. terminal 30), the vehicle cable from the batteryto the fuse box must be included in rating the overallcable length and possibly re-dimensioned ifnecessary.

• Insulate unused cable ends.

Electrical system5

Parts list for the circuit diagrams

Parts list for the circuit diagrams HYDRONIC

1.1 Burner engine1.2 Glow plug1.5 Overheating sensor1.12 Flame sensor1.13 Temperature sensor

2.1 Controller2.2 Fuel dosing pump2.5.7 Relay, vehicle fan2.7 Main fuse 20 A2.7.1 Fuse, actuation 5 A2.7.5 Fuse, vehicle fan 25 A2.12 Water pump

5.1 Battery5.1.2 Fuse block in the vehicle5.9.1 Switch, vehicle fan5.10 Vehicle fan

a) Connect to D+ for extra heating optionf) Disconnect lineg) For petrol onlyh) For diesel onlyk) Switch (extra heating, e.g. outside temperature

< 5 °C or summer/winter change-over)

The circuit diagrams are printed at the end ofthis manual.

Connectors and bush housings are shown fromthe cable inlet side.

Please note!

Please note!

Page 34: Hydronic d5sc Td 06-2007 En

34

Cable colours

rt = redbl = bluews = whitesw = blackgn = greengr = greyge = yellowvi = violetbr = brownli = purple

Parts list for circuit diagram control units– part 3.1 and 3.2

2.15.1 Temperature sensor (room temperature)2.15.9 Temperature sensor (outside temperature)

3.1.16 Button, radio remote control3.1.18 Button, CALLTRONIC

3.2.12 Timer, mini 12 / 24 volt3.2.14 Timer, mini lighting blue – 12 volt only

3.3.7 Radio remote control TP53.3.8 Remote control, CALLTRONIC

3.8.3 Antenna

3.9.1 Diagnosis unit JE diagnosis

z) Terminal 58 (lighting)

Parts list for the circuit diagrams

Parts list for the circuit diagram control unit– part 1 and part 2

2.15.9 Temperature sensor (outside temperature)

3.1.9 Change-over switch “heating / venting”3.1.16 Button, radio remote control

3.2.9 Timer, module timer3.2.12 Timer, mini 12 / 24 volt3.2.14 Timer, mini lighting blue – 12 volt only

3.3.6 Radio remote control (receiver) TP41i

b) Connect to terminal +15 when heating moderequired > 2 h (with ignition switched on).

c) Lighting terminal 58d) Pre-heating with vehicle fan (option)e) External button ON / OFF (option)i) Connection radio module receiver TP 4i

Electrical system5

The circuit diagrams are printed at the end of thismanual.

Connectors and bush housings are shown fromthe cable inlet side.

Please note!

Page 35: Hydronic d5sc Td 06-2007 En

35

Troubleshooting / Maintenance / Service6

In case of faults, please check the followingpoints

• If the heater does not start after being switched on:– Switch the heater off and on again.

• If the heater still does not start, check whether:– There is fuel in the tank?– The fuses are OK?– The electrical cables, connections etc. are OK?– Anything is clogging the combustion air supply or exhaust system?

Troubleshooting

If the heater remains faulty even after these pointshave been checked, or another malfunction occursin your heater, please contact:• For installation ex works, your contract workshop.• For subsequent installation, the workshop who

installed your heater.

Please note that warranty claims can be become voidif the heater is changed by a third party or by thisinstallation of third party parts.

Maintenance instructions

• Switch the heater off once a month for about10 minutes, even outside the heating period.

• Before the heating period starts, the heater shouldundergo a trial run.If persistent extreme smoke develops, unusualburning noises or a clear fuel smell can be perceivedor if electric/electronic parts heat up, the heatermust be switched off and put out of service byremoving the fuse.In this case, the heater should not be started upagain until it has been checked by qualified staffwho have been trained on Eberspächer heaters.

• Check the openings of the combustion air supplyand exhaust system after longer standstill periods,clean if necessary!

Service

If you have any technical queries or problemswith your pre-heater, dial the following servicephone number:

HotlinePhone 00 49 (0)800 / 12 34 300

Fax hotlineFax 00 49 (0)1805 / 26 26 24

Please note!

Page 36: Hydronic d5sc Td 06-2007 En

36

Environment7

EU Declaration of Conformity

With regard to the following products

Heater type HYDRONIC

we herewith confirm that it conforms with the primesafety requirements stipulated in the directives of theEU Council for harmonisation of the legal regulationsof the member states with regard to electromagneticcompatibility (89 / 336 / EEC).This declaration applies to all heaters producedaccording to the production drawings HYDRONICwhich are an integral part of this declaration.The following standards / directives have been usedto assess the product with regard to electromagneticcompatibility:• EN 50081 – 1 Basic form interference emission.• EN 50082 – 1 Basic form interference resistance.• 72 / 245 / EEC – Modification status 95 / 54 / EU

interference suppression in motor vehicles.

Certification

The high quality of Eberspächer’s products is the keyto our success.To guarantee this quality, we have organised all workprocesses in the company along the lines of qualitymanagement (QM).Even so, we still pursue a large number of activitiesfor continuous improvement of product quality in orderto keep pace with the similarly constantly growingrequirements made by our customers.All the steps necessary for quality assurance arestipulated in international standards.This quality is to be considered in a total sense.It affects products, procedures and customer/supplierrelationships.Officially approved public experts assess the systemand the corresponding certification company awardsa certificate.

Eberspächer has already qualified for the followingstandards:

Quality management as perDIN EN ISO 9001:2000 and ISO/TS 16949:1999

Environment management system as perDIN EN ISO 14001:1996

Disposal

Disposal of materialsOld devices, defect components and packagingmaterial can all be separated and sorted into pure-grade factions so that all parts can be disposed of asrequired in an environment-friendly manner or recycledwhere applicable.Electric motors, controllers and sensors (e.g.temperature sensors) are deemed to be “electronicscrap”.

Dismantling the heaterThe heater is dismantled according to the repairstages in the current troubleshooting / repairinstructions.

PackagingThe packaging of the heater can be kept in caseit has to be sent back.

Page 37: Hydronic d5sc Td 06-2007 En

37

Lists8

List of key words A – Z

Keyword Page

AAccident prevention ................................................... 7Altitude ..................................................................... 31Ambient temperature ......................................... 12, 13Arrangement of the heater ......................................... 5

BBubble formation ...................................................... 24

CCable colours ........................................................... 34Cable harnesses ................................................. 8, 10Cable lengths ........................................ 25, 26, 28, 29Certification .............................................................. 36Circuit diagrams (at the end of the manual)Cooling water circuit ......................................... 18 – 21Combination valve .................................................... 21Combustion air system ............................................. 23Contents ..................................................................... 2Concept of this manual .............................................. 3Control in heating mode ............................................ 31Controls .................................................................... 32Connection to the coolant circuit ..................... 18 – 21

DDescription of functions ........................................... 31Declaration of conformity ......................................... 36Disposal .................................................................... 36Dosing pump ............................................................. 27

EElectronic components ...................................... 33, 34Emergency shut-down .............................................. 32Emergency off .......................................................... 32Environment .............................................................. 36EU Declaration of Conformity .................................... 36Exhaust .................................................................... 22Exhaust system ............................................. 5, 22, 23Extra parts ........................................................... 8, 10

FFastening .................................................................. 16Faults ....................................................................... 35Forced shut-down ..................................................... 32Fuel .................................................................. 24 – 30Fuel withdrawal ................................................. 24 – 29Fuel system ...................................................... 24 – 30Fuel quality ........................................................ 27, 30Fuel supply ....................................................... 24 – 30Fuel feed .................................................................... 5

Keyword Page

HHeating operation ..................................................... 31Heat flow ........................................................... 12, 13Hotline ...................................................................... 35

IInformation ................................................................. 4Installation location .................................................. 15Installation positions ................................................ 16Instructions ........................................................... 4, 5Installation ......................................................... 15, 16Introduction ................................................................ 2Initial commissioning ................................................ 31Interference suppression class ......................... 12, 13

LList of abbreviations ................................................. 38

MMain dimensions ....................................................... 14Materials ................................................................... 36Maintenance ............................................................. 35

NNameplate ................................................................ 17

OOperation .................................................................. 31Operating instructions .............................................. 31

PPicture symbols .......................................................... 4Power consumption ............................................ 12, 13Presentations ............................................................. 4Pressure side ................................................... 25 – 27Protection .......................................................... 12, 13Proper use .................................................................. 4Purpose ...................................................................... 4

RRated voltage .................................................... 12, 13Regulations ............................................................ 5, 6

SSafeguards ............................................................... 32Scope of supply ................................................. 8 – 11Special text structure ................................................. 4Statutory regulations ............................................. 5, 6Storage temperature .......................................... 12, 13Starting procedure .................................................... 31Suction height ........................................................... 27Switching on ............................................................. 31

Page 38: Hydronic d5sc Td 06-2007 En

38

Lists8

List of key words A – Z

Keyword Page

TTest symbol ................................................................ 5Text structure ............................................................. 4Technical data ................................................... 12, 13Troubleshooting ........................................................ 35T-piece ............................................................... 25, 28

VVoltage .............................................................. 12, 13Voltage limit ....................................................... 12, 13

WWiring ....................................................................... 33Weight ............................................................... 12, 13

List of abbreviations

ADREuropean agreement about the international transportof dangerous goods on the road.

ADR99Dangerous goods regulations for France.

EC type approvalPermit awarded by the Federal Vehicle Office for theproduction of a heater for installation in motorisedvehicles.

EMC directiveElectromagnetic compatibility.

JE partnerJ. Eberspächer partner.

PMEBiodiesel as per DIN V 51606.

Page 39: Hydronic d5sc Td 06-2007 En

39

25 1920 00 96 01 D

Circuit diagram HYDRONIC

Parts list, page 33, 34

Page 40: Hydronic d5sc Td 06-2007 En

40

25 1920 00 97 01 CParts list, page 33, 34

Circuit diagram control elements – part 1

Page 41: Hydronic d5sc Td 06-2007 En

41

25 1920 00 97 01 C

25 1920 00 97 02 B

Circuit diagram control elements – part 2

Circuit diagram control elements – part 3.1

Parts list, page 33, 34

Page 42: Hydronic d5sc Td 06-2007 En

42

25 1920 00 97 02 B

Circuit diagram control elements – part 3.2

Parts list, page 33, 34

Page 43: Hydronic d5sc Td 06-2007 En

43

Page 44: Hydronic d5sc Td 06-2007 En

20 1

824

90 9

6 89

EN

06.2

007

Sub

ject

to c

hang

esP

rinte

d in

Ger

man

J. E

bers

päch

er G

mbH

& C

o. K

G

www.eberspaecher.com

J. EberspächerGmbH & Co. KGEberspächerstr. 24D - 73730 EsslingenTelefon 0711 939 - 00Telefax 0711 939 - [email protected]