Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá Di Roma 25 – 27 June 2008
Transcript
Page 1: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Hydrophone based calibrator for seawater acoustic detection of

UHE neutrinos

Omar Veledar

ACoRNE collaboration – University of Sheffield

Sapienza Universitá Di Roma25 – 27 June 2008

Page 2: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Outline

Rona array DAQ Calibration Pinger development Deployment Future work

Page 3: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Rona hydrophone array

• North-West Scotland (ranging hydrophones)• Good test bed for future deep sea experiments

• Existing infrastructure √• Wideband hydrophones √• Omnidirectionality √• Unfiltered data √• All data to shore √• Control over DAQ √• No remote access X

Page 4: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Rona hydrophone array

8 hydrophones Low noise preamplifiers 1200m x 200m at mid

depth in 230m deep sea Hydrophone positioning

off during data readout

Page 5: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

DAQ

Offshore acquisition of amplified unfiltered data (16bit ADC@140kHz, ±1.2 V, 1bit = 38.147μV = 3662.1μPa)

FLAC lossless compression (>50%)

8TB RAID interfacing to

16 tape autoloader LT03

tape robot (possible to

relocate) Offline signal processing

and analysis - unlimited data re-processing

Quantum Superloader 3

Page 6: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Calibration - hydrophone

Acoustic detection of UHE neutrinos relies on ability to calibrate hydrophones - bipolar acoustic pulse from single omnidirectional source

Thermal energy resembling (shape and intensity) that of a neutrino induced shower should be deposited: array - interface pattern analogous to neutrino generated ‘pancake’

Other possibilities: Laser – interesting, but impractical Copper plate current discharge

Page 7: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Calibrator development - progressionLaboratory tank

Swimming pool

Lake (Kelk)

Open sea (Rona)

Development

Page 8: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Calibrator development - toolsTx – omnidirectional ± 1.8dB @ 10kHz Rx - flat frequency response

Page 9: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Know system and desired output to deduce required excitation pulse

Convolution integral (t)y(t) = x(t) * h(t) - complicatedConvolution (s) - freq. domain

Y(s) = X(s) . H(s)

Inverse FFTy(t) = IFFT(Y(s))

Impulse response not practical use step response

Step response = time integral of impulse response

Signal generation - system

i

invixnvnx ][][][*][

dtgftgtf )()()(*)(

0,0

0,)(

x

xx

(hydrophone)input output

system & output => excitation pulse

Time domain

Discrete time signal

Impulse

xdttxH )()(

Step

Page 10: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Signal generation - signal

d / dtstepHydro

system H(t)

o/pImp. resp.

Deconvolute i/p from sys. & o/pX(s) = Y(s) / H(s)

Transform to time domainx(t) = IFFT(X(s))

RECIPE Find step response (of the transmit hydrophone) Generate system TF (model transmit hydrophone) Find excitation signal by deconvoluting required o/p and system TF

Page 11: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Pool – hydrophone modelling

Hydrophone step response is recorded at various distances and dejittered

Page 12: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Hydrophone data fitting

5th order TF used to model hydrophone

TF:Mathematical representation of the relationship between the i/p and o/p of a LTI system

Page 13: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Technique verification

Page 14: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Excitation signal

Desired acoustic pulse and the estimated hydrophone driving electrical signal

Generates10 Pa @ 1m

Page 15: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Pool - bipolar acoustic pulse

Measured at various distances

Page 16: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Rona - field trip

The joys of British “Summer”

Page 17: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Future work

Repeat Rona deployment at different sea state and over different hydrophones using new excitation pulses

An array development using 8 hydrophones Line array – acoustic pancake

Fully autonomous for great depths Surface deployment => Power Amplifier, easy DAQ,

(linearity?)

Field data analysis

Page 18: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

New excitation signal

Restrictive by the hydrophone linearitypotentially, can generate up to

approximately 60 Pa @ 1m

See Bevan et al. – parameterisation:more energy at core of the shower

Page 19: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Array hydrophone count2 hydrophones

4 hydrophones

8 hydrophones

3 hydrophones

6 hydrophones

10 hydrophones

Page 20: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Array development

Acquired RESON hydrophones

Developed PIC based hydrophone control

Array construction under way

Page 21: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Conclusions

Understood and mathematically modelled hydrophone system

Successfully generated bipolar acoustic pulses in laboratory and pool conditions

Ongoing Rona data analysis Array development Pancake detection

Page 22: Hydrophone based calibrator for seawater acoustic detection of UHE neutrinos Omar Veledar ACoRNE collaboration – University of Sheffield Sapienza Universitá.

Thank you

Questions ?

http://pppa.group.shef.ac.uk/acorne.php