University Centre for Energy Efficient Buildings CTU in Prague
The aim of the Centre is to promote energy efficient and environmentally friendly buil dings that are comfortable for their users.
Measuring of thermal and moisture characteristics of building materials,
constructions, and spaces
Třinecká 1024,273 43 Buštěhrad,Czech [email protected]+420 224 356 711+420 778 411 622
Main Activities of the Laboratory
Measuring of hygrothermal characte ristics of building materials and con structions
Diagnostics of hygrothermal behaviour of constructions and spaces of real buildings
Optimization of design of building constructions with regard to moisture and microbiological risks
Computer simulations of transfer of heat and moisture transfer, and risks of mold growth
Hygrothermal Laboratory
Buštěhrad, CZ
References
Diagnostics and analysis of hygrothermal and microbiological behaviour of cold deck flat roofs and of composition of cold attics
Influence of hydrophobization of wood on its sorption properties and water vapour permeability
Simulation of moisture buffering effect in an interior using clay panels
Experimental Crawl Space (analysis of hygrothermalbehaviour and microbiological risks in the space under raised floors)
Air permeability of a roof structure with a sprayed PU foam
Drying of moist brick walls with a historical painting
Instrumentation
Small double climate chamber (samples with dimensions up to 1.0 × 1.0 × 0.6 m, thermal range from –45 °C up to +180 °C)
Devices for measuring of heat conductivity of building materials: heat flow meter (HFM), Isomet
Device for measuring of water vapour permeability
Set of cabinet vacuum desiccators
A&D sensors for measuring of temperature, relative humidity, heat flow, wind speed, solar irradiance, pressure difference, etc.
Software Equipment
Delphin 2D
Comsol, Matlab
Measurements and Surveys
Accredited Measurement Determination of thermal resistance using
a heat flow meter (EN 12667), determination of water vapor transmission properties (EN ISO 12572), determination of moisture content by drying (EN ISO 12570)
Other Measurements Determination of hygroscopic sorption
properties, capillary absorption, open porosity, and weight by volume
Diagnostics of Constructions Insitu measuring and analysis of hygro
thermal problems of constructions
Computer simulations Simulations of transfer of heat and mois
ture, optimization of design of building constructions and spaces
About the Laboratory
The aim of the laboratory is to provide comprehensive measuring of physical parameters related to the transfer and accumulation of heat and moisture in building materials, constructions, and spaces. The equipment allows for laboratory measuring as well as for insitu measuring (at the construction site).