I-CASS – Door Access System THE LEADING INNOVATOR OF SECURITY SYSTEM
Transcript

I-CASS – Door Access System

THE LEADING INNOVATOR OF SECURITY SYSTEM

Table Of Content

1. Introduction to I-CASS.

2. Comparison with K-series.

3. System Component.

4. System configuration.

5. System Technology.

6. I-Cass Features.

7. Technical Specification.

8. Precaution & Maintenance.

System Introduction(1)

• Max.32 doors access control system.

• Categorized into 2/4/8/12/16/24/32 doors version.

• Combination of existing door access system, time attendance system, and alarm monitoring system.

T-series : Multi-door interlocking featuresK-series : Auxiliary Output relay based on

defined transaction.FEP : Supervised alarm input points.

System Introduction(2)

Bring in wireless messaging technology. Short message service among very doors. Huge user and transaction storage capacity. High speed processing and respond time. Interactive blue light graphic LCD display Emergency over ride key( Electronic Key). Long reading range for proximity technology. Ready for mifare and wiegand 26/32bits.

Integrated with S-series, K-series, T-series, Commando, Centurion and FEP alarm monitoring system design concept.

1. People choose I-CASS for its flexibility usage in security access control and other relevant application such as:

1.Multi-door anti-pass back that handling max.32 doors operation.

2.Multi-door interlocking features that only allow one door to grant access at a time.

3.Guard Tour application that enabling patrol guard perform checking duty.

4.Ethernet and GSM ready for internal and external communication.

5.Alarm break in protection.6.Fire alarm emergency exist.

System Introduction(3)

System Introduction(4)

• Dual card entry mode and access counter mode for restricted access area.

• CCTV and building automation integration.

• 125Khz and 13.56MHz proximity technology interfacing.

• I-CASS is designed to meet customer application including

– Door access control

– Guard tour patrol

– Time Attendance

– Alarm monitoring

– Car Parking control

– Building automation

– Fire alarm panel integration

– CCTV integration

– SmartCard based solution

How security handled in I-CASS?

• System wiring design

• Electronic key design

• Communication data protection

• Emergency event or alert

• Low power and main fail power detection

• Communication break down protection

• Watch dog for safe guard

Benefit of using I-CASS

• To have more card user capacity in the system.• To have a high speed and fast processing time for every

operation.• To have a large door capacity controlled under one controller.• To have a alarm monitoring features at every door.• To have a guard tour features at every door.• To have SMS messaging service among door reader.• To have variety choice of operation mode at every door.• To have interactive graphic display on every door reader.• To have emergency over ride system• To have Ethernet ready capability

Comparison with existing controller(1)

Feature/Spec. K-series I-CASSInterlocking No 5 door per group

(100 group)

Anti-pass back Available among max. 8 doors

Available among

Max.32 doors

Dual card access No Available

(100 match code)

Access Counter No Available on every door setting

Emergency Key override

Tabular key lock Electronic key with 4 digits password.

Display unit Normal dot matrix

LCD

Graphic LCD with blue backlit

Comparison with existing controller(2)

Features/Spec. K-series I-CASSEthernet No On board Ready

GSM SMS No Ready

Alarm monitoring Based on TTL input on every controller only

2 supervised sensor points on every door

Fire alarm No Fire alarm for emergency door release

Guard Tour No Available on every door ready as checking terminal.

Auxiliary Output Available Available

Comparison with existing controller(3)

Feature/Spec. K-series I-CASSSpeed 8Hz 24MHz

User storage 5,000 users 20,000 users

Transaction storage 2,500 50,000 users

Door connection Max. 8 doors Max. 32 doors

Processor 8 bits MCU 16 bits MCU

RAM 128K Byte 2M byte

Comparison with existing controller(4)

Feature/Spec. K-series I-CASSShort Messaging Service

No Available among door readers

Door release time zone No Available on every door setting

Lock out mode No Available on every door setting

Emergency duress alarm

Available Available

General purpose relay output

No Available on controller

Software 32bits SmartGuard series software

32bits SmartGuard I-CASS software

Level of Changes

2Mhz

6Mhz

1024KB

128KB

3

8

19200bps

9600bps

32

16

60% more

40%

BusFrequency

OnboardRAM

UARTSize

Comm.Speed

DoorConnection

Over allFeatures

Existing System

I-CASS System

Comparison with Castle-S/K/T&Commando System

System Component(1)

• I-CASS controller• SmartBox (Door Interface Unit)• Door Reader• Electronic Key• Power Supply• PC interface (PCI)• SmartGuard I-CASS v5.6• Used as real time processing unit for all door event and alarm.• As card user databases storage.• As log transactions storage.• Used for all the user setting.• Responsible for all the communication bus polling.

System Component(2)

SmartBox-Door Interface Unit

• Used to control the electronic door lock device, door contact and lock release button.

• Used as reader interface communication gateway to controller.

• Perform basic door controlling function during system controller breakdown.

System Component(3)

I-CASS Reader Interface

• Act as reader interface for proximity reader.

• Mifare® serial number interfacing.

• Wiegand 26bits interfacing.

• Keypad and LCD interfacing.

• Perform card number conversion.

• Display informative message.

• PIN generator

• Alarm arming and disarming interface panel

System Component(4)

Electronic Key

• Connected to reader interface board

• Used during emergency breakdown to over-ride the door lock.

• Security key is stored with a standard encryption technique.

• 10 digits key with suitable password to release door lock.

System Component(5)

PC Interface Unit (PCI)

• Used as a gateway for controller uplink and PC communication port.

• Used as a signal converter for RS232 to RS485 communication.

• Act as a software security key for software version determination.

System Component(6)

SmartGuard –ICASS v5.6

• 32bits PC software.

• Act as a interface software for data or user setting downloading machine.

• Act as log transaction uploading software for data reporting purpose.

• Time attendance report generation.

System Configuration(1)

RS 485

RS 232

In Reader

Out Reader

PC Interface

Door Interface

(2)

Door Interface

(4)

Push Button

Door Interface

(5)

I-Cass Software

RS 485

BUS 4

BUS 3

BUS 2

BUS 1

I-CASS Controller PC I

RS 232

Maximum 8 doors (expandable)

Door Interface

(3)

E-Key

E-Key

Lock System

Magnetic Sensor

2 Wires

Door Interface

(1)

I-Cass Features

Polycarbonate Keypad E - Key

LCD ScreenABS Casing

Proximity Technology

Press Alarm

Alarm Systems

Networking

SMS

Guard Tour

Time Attendance

Features Highlighted (1)

• Enable Short Message Service (SMS)

• Inbound System

• Outbound System

Storage Capacity: 100 users with 50 characters each user.

Doors forced open or burglary

Doors forced open or burglary

OwnerOwnerSMS

Preset greetings or short messages

Preset greetings or short messages EmployeesEmployees

SMS

Features Highlighted (2)

• Guard Tour Feature

Time set : 20 minsTime set : 10 mins

Main Back Off

Door 1 Door 2 Door 3

1. Configuration

Back

Time set : 20 minsTime set : 10 mins

Main Off

Door 1Door 3Door

2 “Beep”

2. He/She did not proceed to Door 2

3. He/She did not proceed to Door 3

Time set : 20 minsTime set : 10 mins

Main Back Off

Door 1 Door 2 Door 3

“Beep”

Features Highlighted (3)

• Controller storage capacity :

• Standard 20,000 users.

• Expandable to 100,000 users

• Event Transaction Storage Capacity:

• Maximum 30,000 events

• Multi door Anti-pass back.

• Multi door Interlocking

• On board alarm input and output point.

• Dual Card Mode.

Features Highlighted (4)

• Access Counter.• Time Zone Control Door Release Button • 2 Holiday Groups @ 50 settings per group.• Software Configurable to general purpose relay output.• Enable to Interface with CIA88 additional alarm input or output

point.• Maximum 32 doors linkage per controller.• Keypad arming on every door.• Controller backup.• Electronic Key (E-Key) for emergency door release.• Support K series feature.• On board Ethernet.• Graphic LCD.

~ The End ~