Characteristics : I-Touch switches are designed to control resistive, inductive and capacitive loads in residential and commercial premises, either operated
manually (feather touch) or by using RF remote control (103268). Besides switching “ON” and “OFF” it is possible to have Scene settings from the remote. Super
luxurious in appearance the blue backlit touch keys make it easier and convenient to operate in the dark. The appliance is equipped with micro controller chip to
save the parameters preset by the user thereby designed to cater user needs with easy operation.
I-TOUCH SWITCH (Wireless RF Touch Switch with Scenario Function)103244
Instruction Sheet
Salient features :
Designed with SMPS for improved reliability, over current and over voltage protection.
Provided with in-built surge protection.
Relay based with obstruction free RF control.
Operates by feather touch or using remote control (103268)
Equipped with blue backlit keys for convenience in dark.
Beep sound for feedback of the key operation.
Facilitates easy scene setting from remote.
OFF timer function
Simple retrofit installation.
Does not require special wiring.
Operations
a) Manual : The i-touch switch panel is provided with touch screen with 4 switches together with 1 master key. The individual switches are operated by feather
touch & the entire panel i.e. all 4 switches can be operated simultaneously by touching the master key.
b) Through Remote : The individual switches or the master key can be operated through Remote by pressing the assigned button on Remote.
Functions of Remote
(a) Setting Remote address : User can set remote to specific five digit code so it won't interfere or clash with switches controlled by other remote. Press “setup”
and “0” button of the remote together for three seconds ( the LED of the remote will start blinking ) then press any five digits for your new code. The default
remote address will be “00000”.
(b) Assigning Remote Button with the Receiver Key : Long press the panel key corresponding to the appliance to be assigned on the touch panel (for seven
seconds), till the master key LED on the panel starts blinking with a long beep. Then press any numerical button of the remote control you desire to assign. After
successful assignment the master key LED will stop blinking accompanied by a short acknowledging beep from receiver.
Note : 1) If key of the receiver ( touch panel) has already been assigned with another button on the remote then the previous address assigned will be deleted
automatically. 2) If the same button of the remote other receiver then one button will function for two receivers.is already assigned to the key from
(c) Assigning Master key of the panel to particular button on the remote : Long press the master key on the panel for seven seconds the 4 switch keys will start blinking with a long beep. Then press the desired button of the remote you wish to assign. After successful setup the switch keys LED will stop blinking accompanied by a short beep. Now the master switch on the panel can operated by the assigned button on the remote.
(d) Setting Remote Enable or Disable function (child Safety) : Long press the panel key (on the panel) corresponding to the appliance to be enabled or disabled from the remote (for seven seconds), till the master key LED on the panel starts blinking Then press enable or disable button on the remote control. After successful setup the master key LED on panel will stop blinking . This setup will help you to include or exclude particular load into the Remote.
Note : In Remote disable function, all the buttons on Remote including, timer ‘ALL ON’ ‘ALL OFF’ will not work but the disable address will keep on working in scene function. To delete from scene we need to use scene disable setting.
(e) All “ON” / All “OFF” Function : All Assigned devices on the remote can be turned “ON” or “OFF” at the same time using ALL “ON” or ALL “OFF” button on the remote subject to selection of scene or remote disable settings for the specific loads.
with a long beep. accompanied by a short acknowledging beep from receiver
103244
Receiver
Master Key
Blue Backlit Keys
Technical Specifications
Rated Voltage : 110-264 0-60Hz
Radio Frequency : 433.92 MHz
Rated Load per :
a) Resistive Load – Tungsten & Halogen lights : 1000 W
b) Capacitive Load – Fluorescent and CFL : 200W
c) Inductive Load – Fan and Motor :
Power consumption in standby mode : 0.2W
Humidity Range : between 10-50 degree centigrade – 95% RH
Service Life :
a) Touch sensor : 10 lacs operation
b) Integral relay : 1lac operation
Conformity code : CE, ROHS
Suitable for mounting on inflammable surface
Impact protection : IK02
Class two appliances
Size : Three module
V AC 5
Switch
1000WM
F
S W I T C H E S A N D S Y S T E M S
Customer Care Toll Free No.
1800 209 0234
GOLDMEDAL ELECTRICALS PVT. LTD. 22/23, Shubh Building, Sagar Manthan Ind. Complex, Bhoidapada, Vasai (E), Thane-401208, Maharashtra, India.
www.goldmedalindia.com
Goldmedal Unless otherwise specified, the products illustrated in this Leaflet have been designed by Goldmedal and are covered by one or more international patents. X
F
(f) Setting Scene Function : User can set upto eight scenes by using the remote. Step-1 : Set the connected appliances at desired level i.e intensity of the light, switches “ON” or “OFF”, curtain status etc. Step-2 : Press the setup button on the remote and then press the desired scene button you want to assign, status of all your dimmer, switches and curtains will be saved in particular selected scene button.
(g) Scene Enable or Disable function : Long press the panel key (on the panel) corresponding to the appliance to be enabled or disabled from the remote (for seven seconds), till the master key LED on the panel starts blinking Then press the scene enable or disable button on the remote. After successful setup the master key LED will stop blinking . This setup will help you to include or exclude particular load into the scene.
(h) OFF Timer function : Press and hold setup button on the remote, the LED on the remote will blink once, then without releasing the setup button, press and hold the desired timer button, the LED of the remote will glow for little longer. Then press the assigned key on the remote you wish to switch OFF in particular time. There will be a short acknowledging beep from receiver. Time delay can be set to 15min, 30min, 45min & 1 Hour.
General note : During setup or assigning the user should complete the operation within to complete the setup or else the unit will come back to normal mode instead of setup mode.
with a long beep. accompanied by a short acknowledging beep from receiver
20 seconds
LNL1L2L3L4
N
L
Load
Antena
L N
L1 L2 L3 L4
Cu ve103244UP
REGD. DEGN
FWIRELESSRECEIVER
Wireless RF Switch with Scenario Function Radio Frequency : 433.92 MHzSupply Voltage:160-240V~ 50Hz
Controllable Load Each Resistive Load : 6 AIncandescent & Halogen Lamp : 1000 WFerromagnetic Transformer : 1000 VAElectronic Transformers : 700 VACompact Fluorescent Lamp : 100W (Max)
56.5 mm
43 mm
Wiring Diagram Elevation and side view show the overall dimensions
and the flush depthDimensions (mm)
103244
Special Features :
This remote is operated on radio frequency hence is effective to operate from all direction upto
distance of 20 metres. The effectiveness of the remote remains unobstructed even across the wall &
when the receiver is out of sight.
The controls are effected in a safe manner since there are no electrical connections between the
remote control and the load.
Suitable for places where high safety is required, for disabled persons and wherever it is difficult to
physically reach the control point and controlled device.
Safety instruction
Electrical equipment must be installed and fitted by a
qualified electrician only.
The electronic switches are single pole switches and
disconnect only one pole when they are OFF.
Before working on the appliance, to prevent electric
shock, disconnect both the poles of the main supply.
Failure to observe any of the installation instruction
may result in fire and other hazards.
a)
b)
c)
d)
e)
f)
g)
h)
i)
All ‘ON’ and All ‘OFF’
Scene Creation
Setup
Dimmer and Fan Regulator (for dimming)
Curtains Up and Curtain down
Timer (15 min, 30 min, 45 min, & 60 min)
Numerical button
Scene Enable and Scene Disable
Remote Enable and Remote Disable
2 buttons
8 buttons
1 button
2 buttons
2 buttons
4 buttons
12 button
2 buttons
2 buttons
Functions : It comprises following function buttonsRF REMOTE
scene 1 scene 2 scene 3 scene 4
scene 5 scene 6 scene 7 scene 8
All ON All OFF
T15
SETUP
1 2 3 4
5 6 7 8
9 0 +10 +20
T30
T45
T60
SETUP
enable disable
scene remote
enable disable
103268
LED
DIMMING KEYS
TIMERKEYS
TIMER
Example of use
Example of use
Example of use