Date post: | 03-Apr-2018 |
Category: |
Documents |
Upload: | astrolab4208 |
View: | 216 times |
Download: | 0 times |
of 26
7/28/2019 ICASS
1/26
I-CASS Door Access System
THE LEADING INNOVATOR OF SECURITY
SYSTEM
7/28/2019 ICASS
2/26
Table Of Content
1. Introduction to I-CASS.
2. Comparison with K-series.
3. System Component.4. System configuration.
5. System Technology.
6. I-Cass Features.7. Technical Specification.
8. Precaution & Maintenance.
7/28/2019 ICASS
3/26
Sys tem Introduct ion (1)
Max.32 doors access control system.
Categorized into 2/4/8/12/16/24/32 doors version.
Combination of existing door access system, time attendance
system, and alarm monitoring system.
T-series : Multi-door interlocking features
K-series : Auxiliary Output relay based on defined
transaction.
FEP : Supervised alarm input points.
7/28/2019 ICASS
4/26
Sys tem Introduct ion (2)
Bring in wireless messaging technology.
Short message service among very doors.
Huge user and transaction storage capacity.
High speed processing and respond time.
Interactive blue light graphic LCD display
Emergency over ride key( Electronic Key).
Long reading range for proximity technology.
Ready for mifare and wiegand 26/32bits.
Integrated with S-series, K-series, T-series, Commando,Centurion and FEP alarm monitoring system design concept.
7/28/2019 ICASS
5/26
1. People choose I-CASS for its flexibility usage in securityaccess control and other relevant application such as:
1.Multi-door anti-pass back that handling max.32 doorsoperation.
2.Multi-door interlocking features that only allow one door togrant access at a time.
3.Guard Tour application that enabling patrol guard performchecking duty.
4.Ethernet and GSM ready for internal and external
communication.5.Alarm break in protection.
6.Fire alarm emergency exist.
Sys tem Introduct ion (3)
7/28/2019 ICASS
6/26
Sys tem Introduct ion (4)
Dual card entry mode and access counter mode for restricted
access area.
CCTV and building automation integration.
125Khz and 13.56MHz proximity technology interfacing.
I-CASS is designed to meet customer application including
Door access control Guard tour patrol
Time Attendance
Alarm monitoring
Car Parking control Building automation
Fire alarm panel integration
CCTV integration
SmartCard based solution
7/28/2019 ICASS
7/26
How secu ri ty hand led in I-CASS?
System wiring design
Electronic key design
Communication data protection
Emergency event or alert Low power and main fail power detection
Communication break down protection
Watch dog for safe guard
7/28/2019 ICASS
8/26
Benef i t of using I-CASS
To have more card user capacity in the system.
To have a high speed and fast processing time for everyoperation.
To have a large door capacity controlled under one
controller. To have a alarm monitoring features at every door.
To have a guard tour features at every door.
To have SMS messaging service among door reader.
To have variety choice of operation mode at every door.
To have interactive graphic display on every door reader.
To have emergency over ride system
To have Ethernet ready capability
7/28/2019 ICASS
9/26
Compar ison w ith exist ing contro l ler (1)
Feature/Spec. K-series I-CASSInterlocking No 5 door per group
(100 group)
Anti-pass back Available among max. 8
doors
Available among
Max.32 doors
Dual card access No Available
(100 match code)
Access Counter No Available on every
door setting
Emergency Keyoverride Tabular key lock Electronic key with 4digits password.
Display unit Normal dot matrix
LCD
Graphic LCD with
blue backlit
7/28/2019 ICASS
10/26
Compar ison w ith exist ing contro l ler (2)
Features/Spec. K-series I-CASSEthernet No On board Ready
GSM SMS No Ready
Alarm monitoring Based on TTL input on
every controller only
2 supervised sensor
points on every door
Fire alarm No Fire alarm for
emergency door
release
Guard Tour No Available on every
door ready aschecking terminal.
Auxiliary Output Available Available
7/28/2019 ICASS
11/26
Compar ison w ith exist ing contro l ler (3)
Feature/Spec. K-series I-CASS
Speed 8Hz 24MHz
User storage 5,000 users 20,000 users
Transaction storage 2,500 50,000 users
Door connection Max. 8 doors Max. 32 doors
Processor 8 bits MCU 16 bits MCU
RAM 128K Byte 2M byte
7/28/2019 ICASS
12/26
Compar ison w ith exist ing contro l ler (4)
Feature/Spec. K-series I-CASSShort Messaging
Service
No Available among door
readers
Door release time zone No Available on every
door setting
Lock out mode No Available on everydoor setting
Emergency duress
alarm
Available Available
General purpose relay
output
No Available on controller
Software 32bits SmartGuard
series software
32bits SmartGuard I-
CASS software
7/28/2019 ICASS
13/26
Level of Changes
2Mhz
6Mhz
1024KB
128KB
3
8
19200bps
9600bps
32
16
60% more
40%
Bus
Frequency
Onboard
RAM
UART
SizeComm.
Speed
Door
Connection
Over all
Features
Existing System
I-CASS System
Comparison with Castle-S/K/T&Commando System
7/28/2019 ICASS
14/26
System Component(1)
I-CASS controller SmartBox (Door Interface Unit)
Door Reader
Electronic Key
Power Supply
PC interface (PCI)
SmartGuard I-CASS v5.6
Used as real time processing unit for all door event and alarm.
As card user databases storage.
As log transactions storage.
Used for all the user setting.
Responsible for all the communication bus polling.
7/28/2019 ICASS
15/26
System Component(2)
SmartBox -Door Interface Unit Used to control the electronic door lock device, door contact
and lock release button.
Used as reader interface communication gateway to
controller. Perform basic door controlling function during system
controller breakdown.
7/28/2019 ICASS
16/26
System Component(3)
I-CASS Reader Interface Act as reader interface for proximity reader.
Mifare serial number interfacing.
Wiegand 26bits interfacing.
Keypad and LCD interfacing. Perform card number conversion.
Display informative message.
PIN generator
Alarm arming and disarming interface panel
7/28/2019 ICASS
17/26
System Component(4)
Electron ic Key Connected to reader interface board
Used during emergency breakdown to over-ride the door
lock.
Security key is stored with a standard encryption technique. 10 digits key with suitable password to release door lock.
7/28/2019 ICASS
18/26
System Component(5)
PC Interface Unit (PCI) Used as a gateway for controller uplink and PC
communication port.
Used as a signal converter for RS232 to RS485
communication. Act as a software security key for software version
determination.
7/28/2019 ICASS
19/26
System Component(6)
SmartGuardICASS v5.6 32bits PC software.
Act as a interface software for data or user setting
downloading machine.
Act as log transaction uploading software for data reporting
purpose.
Time attendance report generation.
7/28/2019 ICASS
20/26
System Configuration(1)
RS 485
RS 232
In Reader
Out
Reader
PC Interface
Door
Interface
(2)
Door
Interface
(4)
Push Button
Door
Interface
(5)
I-Cass Software
RS 485
BUS 4
BUS 3
BUS 2
BUS 1
I-CASS
Controller PC I
RS 232
Maximum 8 doors (expandable)
Door
Interface
(3)
E-Key
E-Key
Lock System
Magnetic
Sensor
2 Wires
Door
Interface
(1)
I C F t
7/28/2019 ICASS
21/26
I-Cass Featu res
Polycarbonate Keypad E - Key
LCD ScreenABS Casing
Proximity Technology
Press Alarm
Alarm Systems
Networking
SMS
Guard Tour
Time Attendance
7/28/2019 ICASS
22/26
Features High l igh ted (1)
Enable Short Message Service (SMS) Inbound System
Outbound System
Storage Capacity:
100 users with 50 characters each user.
Doors forced open
or burglaryOwner
SMS
Preset greetings or
short messagesEmployees
SMS
7/28/2019 ICASS
23/26
Features High l igh ted (2)
Guard Tour Feature
Time set : 20 minsTime set : 10 mins
Main Back Off
Door 1 Door 2 Door 3
1. Configuration
Back
Time set : 20 minsTime set : 10 mins
Main Off
Door 1Door 3oor 2Beep
2. He/She did not proceed to Door 2
3. He/She did not proceed to Door 3
Time set : 20 minsTime set : 10 mins
Main Back Off
Door 1 Door 2 Door 3Beep
F t Hi h l i h t d (3)
7/28/2019 ICASS
24/26
Features High l igh ted (3)
Controller storage capacity : Standard 20,000 users.
Expandable to 100,000 users
Event Transaction Storage Capacity:
Maximum 30,000 events Multi door Anti-pass back.
Multi door Interlocking
On board alarm input and output point.
Dual Card Mode.
F t Hi h l i h t d (4)
7/28/2019 ICASS
25/26
Features High l igh ted (4)
Access Counter. Time Zone Control Door Release Button
2 Holiday Groups @ 50 settings per group.
Software Configurable to general purpose relay output.
Enable to Interface with CIA88 additional alarm input or output
point. Maximum 32 doors linkage per controller.
Keypad arming on every door.
Controller backup.
Electronic Key (E-Key) for emergency door release.
Support K series feature. On board Ethernet.
Graphic LCD.
Th E d
7/28/2019 ICASS
26/26
~ The End ~
~ Thank you ~
Visit our website:www.castle.com.my
for more information.
http://www.castle.com.my/http://www.castle.com.my/