ICG My Ride VX Group room setup ICG My Ride VX Group + ICG Connect room setup
MyrideTablet (incl. wall mount)
MyrideTablet (incl. wall mount*)
* Not included in ICG Connect Stand-Alone package. Only included in ICG MyRide VX Group or Group + Connect packages
Internet
(Optional)
Internet
(Optional)
HDMI or DVI Cable (Max 10m (33ft))
Audio Cable(for DVI or external Audio
system)
Bikes with ANT+ Consoles
ICG Customer Training App**
ICG Customer Training App**
** Works with IC5, IC6 and IC7
HDMI or DVI Cable (Max 10m (33ft))
(Max 50m (164ft))
(Max 50m (164ft))
(Max 50m (164ft))
(Max 50m (164ft))
Audio Cable(for DVI or external Audio
system)
ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)
Ite
ms
ICG
MyR
ide
VX
G
rou
pIC
GM
yRid
eV
X
Gro
up
& IC
G
Co
nn
ect
ICG
Co
nn
ect
ICG
Co
nn
ect
U
pgr
ade
^
AN
T D
ata
Re
ceiv
er
De
live
ry
Re
spo
nsi
bili
ty*
Inst
alla
tio
n
Re
spo
nsi
bili
ty*
Po
siti
on
ing
Re
spo
nsi
bili
ty*
Ele
ctri
calp
ow
er
Ou
tle
t av
aila
bili
ty
Re
spo
nsi
bili
ty*
Co
nn
ect
ivit
y*
Co
mm
en
t
ICG Bikes - - - - - Life Fitness
Life Fitness
Customer - Bluetooth, ANT+ IC5, IC6, IC7 bikes
Media Server
1 1 1 - - Life Fitness
Life Fitness
Customer Customer Audio/Video: HDMI,DVI, headphone jackNetwork: LAN & WIFI
Power supply included. Electrical Power Outlet needed within 1 meter of product. Creates independent pre-configured WIFI network with Tablets. An additional wall mount and table stand is included. Needs to be temporarily connected to internet when additional content needs to be unlocked (Eg. When upgrading to ICG Connect Upgrade package)^
Instructor Tablet
1 1 1 - - Life Fitness
Life Fitness
Life Fitness
Customer WIFI Power supply included. Electrical Power Outlet needed within 1 meter of product. This tablet will be attached to the instructor bike. Auto connects to WIFI network from Media Server.
2nd Tablet 1 1 - - - Life Fitness
Life Fitness**
Customer Customer WIFI Power supply included. Electrical Power Outlet needed within 1 meter of product. This tablet can be attached to the wall or put on a desk etc. with the Tablet Wall Mount. Auto connects to WIFI network from Media Server. **Only when wall mount is installed, otherwise customer responsibility.
Tablet Wall Mount
2 2 - - - LifeFitness
Customer Customer - - For Desk or Wall mount
Router - 1 1 1 - Life Fitness
Life Fitness
Customer Customer LAN (WIFI section not used)
Power supply included. Electrical Power Outlet needed within 1 meter of product.
PoE Injector - 2 2 2 1 Life Fitness
Life Fitness
Customer Customer LAN Power supply included. Electrical Power Outlet needed within 1 meter of product
ANT Data Receiver
- 2 2 2 1 Life Fitness
Life Fitness**
Customer - LAN, ANT 2 ANT Receivers for maximum 40 bikes. For every 20 more bikes, 1 additional ANT Data Receiver needs to be installed. ** Only when wall mount is installed, otherwise customer responsibility.
ANT Data Receiver Wall Mount
2 2 2 1 Life Fitness
Customer Customer - - See “ANT Data Receiver Mounting information” page for more details.
CAT6 Ethernet cables
- - - - - Customer Customer Customer - - Minimum CAT6 quality. Maximum 50 meter (164ft) cable between each hardware componentAll cables have to have 20cm (7.9 inch) spare length at all hardware positions
HDMI or DVI cable
- - - - - Customer Customer Customer - - Maximum cable length = 10 meter (33ft)For longer distances an HDMI extender can be used (customer responsibility*)
Screen or Projector
- - - - - Customer Customer Customer Customer HDMI or DVI Additional audio input needed with DVI,As DVI doesn’t include Audio
Internet - - - - - Customer Customer Customer LAN Strongly suggested (for scheduling & software updates) but optional for the customer. Mandatory during installation when additional content needs to be unlocked (Eg. ICG Connect Upgrade package)^. Minimum Internet bandwidth 1Mbit/s. 6MBit/s recommended
Smartphone - - - - - End User End User End User - Bluetooth End User can connect his/her smartphone through ICG Training App over Bluetooth to the Bike Console. Bike consoles have no option to charge smartphones.
Requirements & Responsibilities
*Any other hardware which is added and used within this setup is the
complete responsibility of the customer
^ To unlock the additional content for this upgrade, the Media Server
needs to be temporarily connected to internet
ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)
Hardware list
PoE InjectorPurpose: adds power over Ethernet for ANT Data ReceiverDimensions: 8x5,4x2,4 cm (3.2x2.1x0.9 inch)Power: 100-240V AC 15.4W
ANT Data Receiver Wall MountPurpose: Secures the ANT Data Receiver to the wall or ceilingDimensions: 12,1*11,9*7 cm (4.8x4.7x2.8 inch)
ANT Data Receiver (Wasp)Purpose: Connects the Bike Consoles to the ICG Connect systemDimensions: 12,1*11,9*3 cm (4.8x4.7x1.2 inch)Power: Power over Ethernet
Media ServerPurpose: Content & Audio/Video server, WifiAccess PointPower: 100-240V AC
RouterPurpose: Network Hub for ICG Connect setupsDimensions: 17,4x3,2x20,0 cm (6.85x1.26x7.87 inch)Power: 100-240V AC
Instructor TabletPurpose: Remote Control & Screen duplicator for the instructorPower: 100-240V AC
2nd TabletPurpose: Secondary Tablet for Virtual timetables & Classes controlPower: 100-240V AC
Tablet Wall MountPurpose: Secures the 2nd
Tablet to the wall or functions as a Tablet Desk Stand
ICG BikesRemarks: The Coach by Color & ICG Connect functionalities require either the IC5, IC6 and/or IC7 bikes
ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)
ANT Data Receiver Mounting information • Can be secured on walls (A) or ceiling (B)• The customer is responsible for drilling the holes for the ANT Data Receivers wall
mounts (use pre-drill template on next page)• 2 ANT Receivers for maximum 40 bikes. For every 20 more bikes, 1 additional ANT
Data Receiver needs to be installed
Wall Mount
Ceiling Mount
ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)
ANT Data Receiver Wall Mount
• Can be used for wall and ceiling mounting
• The Wall Mount template can be used for pre-drilling holes prior to when the actual installation will take place
• The customer is responsible for drilling the holes for the ANT Data Receivers Wall Mounts
• Real size when printed on A4
ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)
Customer Planning Responsibilities
Pre Install
• Plan the position of all hardware
• Install Network cables
• Install all Electrical power sockets
• Facilitate Internet (optional)
• Pre-drill ANT Data Receiver wall mounts
@ Install
• Customer indicates positioning of all hardware to installation team
• For installs with internet connectivity a customer IT specialist needs to be present to support connectivity setup
• Unlock additional content (ICG Connect Upgrade package only)
Post Install
• If any of the customer responsibilities could not be met at installation, the customer is responsible to initiate the finalization of the installation after the original installation timing (through an additional Installation or Service Request. Additional charges apply)
© 2017 Life Fitness, a division of Brunswick Corporation. All rights reserved. (ISBU Installation Support-FK) ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)