www.hunterindustries.com/ICV
ICV IS ONE VALVE READY TO TAKE ON ANY COMMERCIAL HIGH-PRESSURE SYSTEM.
FEATURES• Application:Commercial/municipal• Sizes:1",11⁄2",2",3"• Externalandinternalmanualbleedallows
quickandeasy“atthevalve”activation• Glass-fillednylonconstructionresulting
inthehighestpressurerating• Double-beadeddiaphragmsealdesign
forsuperiorleak-freeperformance• FabricreinforcedEPDMdiaphragmand
EPDMseatensuresuperiorperformanceinallconditions
• DC latching solenoids enable Hunter’s battery-powered controllers
• Captivebonnetboltsprovidehassle-freevalvemaintenance
• LowflowcapabilityallowsuseHunter’smicro-irrigationproducts
• Encapsulated24VACsolenoidwithcaptiveplungerforhassle-freeservice
• Temperaturerating:150°F• Warrantyperiod:5years
ADVANCED FEATURES••Flowcontrol••FilterSentry™
••ReclaimedwaterIDhandle ••Accu-Sync™capable
OPERATING SPECS1"Flowrate:0.1to40GPM11⁄2"Flowrate:20to135GPM2"Flowrate:40to150GPM3"Flowrate:150to300GPMRecommendedpressurerange:20to220PSI
FACTORY INSTALLED OPTIONSValvewithoutsolenoidDClatchingsolenoid
FilterSentry
USER INSTALLED OPTIONSSolenoidconduitcover(P/N464322)DClatchingsolenoid(P/N458200)Accu-SyncpressureregulatorReclaimedwaterIDforICV101,151,and 201(P/N561205)and301(P/N515005)
ICV-101G: 51/2" H x 33/4" L x 4" W
ICV-151G: 71⁄8" H x 67⁄8" L x 51/2" W
ICV-201G: 71⁄8" H x 67⁄8" L x 51/2" W
ICV-301: 103/4" H x 91/4" L x 73⁄8" W
MODELS INLET/OUTLET OPTIONS FACTORY INSTALLED OPTIONS USER INSTALLED
ICV-101G = 1" globe valve (blank) = B =
NPT threadsBSP threads
(blank) = FS =
DC =LS =
No optionFilter SentryDC latching solenoidValve without solenoid
(blank) = R =
CC =DC =
AS-ADJ =AS-20 =AS-30 =AS-40 =AS-50 =AS-70 =
No optionReclaimed water ID tagSolenoid conduit coverDC latching solenoidAccu-Sync adjustable pressure regulator Accu-Sync 20 PSI pressure regulator Accu-Sync 30 PSI pressure regulator Accu-Sync 40 PSI pressure regulator Accu-Sync 50 PSI pressure regulator Accu-Sync 70 PSI pressure regulator
ICV-151G = 1½ " globe valve
ICV-201G = 2" globe valve
ICV-301 = 3" globe/angle valve
EXAMPLES
ICV-101G 1" globe valve, NPT threads
ICV-151G - FS - R 1½ " globe valve, NPT threads, Filter Sentry, and reclaimed water ID tag
ICV Pressure Loss in PSI
GPM 1" 11⁄2" 2"3"
Globe Angle0.1 20.5 21 25 2.5
10 315 320 3 1.530 4 1.5
ICV Pressure Loss in PSI
GPM 1" 11⁄2" 2"3"
Globe Angle40 7 1.7 0.850 2.2 1.260 3 1.775 3.9 2.490 5.5 3.2100 7 4.2120 10.9 6.5135 12.7 7.9
ICV Pressure Loss in PSI
GPM 1" 11⁄2" 2"3"
Globe Angle150 16.2 9.8 2.5 1.9175 13.3 3 2.4200 17.7 4.1 3.3225 5.3 4.3250 6.7 5.5275 8.3 6.9300 10.1 8.5Charts based on full-open fl ow control position
ICV APPLICATION SIZES FLOW RATE
Commercial/Municipal 1", 11⁄2", 2", 3" 0.1 to 300 GPM