  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    1/12

    ID Innovations

    Datasheet for ID-20LF-WR series v1.02 2011-3-01

    - 1 -

    ID-20LF Reader/Write Module 

    User Manual 

    ID Innovations 

    Advanced Digital Reader Technology 

    ------Better by Desig n  

    V1.02—Mar 1, 2011

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    2/12

    ID Innovations

    Datasheet for ID-20LF-WR series v1.02 2011-3-01

    - 2 -

    Summary 

    The ID-20LF series contactless card Read/Write module is based on 3 types 125khz read

    and write chip. They come with the choice of internal antenna (optional) or external antennaand are suitable and for embedded applications and general Electronic Devices. The

    ID-20LF-EM series are user friendly and can be controlled by command from a UART

    (serial port). Functions are selected by a Pin jumper allowing full control of all functions.

    Characteristic 

    .  2 options antenna setting: internal antenna (optional) or external antenna (standard)

    ISP(In System Program)function

    .  Small outline

    .  Low power consumption

    Specification .  Supports Hitags, EM4205/4305,

    .  Model:ID-20MFIA (with internal antenna) ID-20MFWA (without internal antenna)

    .  Frequency:

     

    125KHz

    .  Rear/Write distance: external antenna—up to 50-60mm

    .  External antenna inductance: 345uH

    .  Read/write speed:

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    3/12

    ID Innovations

    Datasheet for ID-20LF-WR series v1.02 2011-3-01

    - 3 -

    mm

    14 

    13 

    12 

    11 

    1 ID-20LF-WR 10 

    2 Bottom View 9 

    3 8 

    4 7 

    5 6  2.54

    9.2m

    11.7mm 21mm

    40mm

    Dimensions and Pins (bottom view) 

    37.

    mm

    m

    0.6 mm

    12.5 mm6.8 mm

    1------GND2------external antenna TX13------external antenna TX24------external antenna RX15------CP6------Future7-----+/- (Format Select)8-----D1(Data Pin 1)9----D0(Data Pin 0)10----LED(LED/BEEPER)11----NC12----RXD13----TXD

    14----+5V

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    4/12

    ID Innovations

    Datasheet for ID-20LF-WR series v1.02 2011-3-01

    - 4 -

    Pin Description & Output Data Formats 

    Pin.NO  Description  ASCII  Magnet Emulation (optional) 

    Wiegand26 (optional) 

    1 Zero Volts and

    tuning Capacitor

    Ground

    GND 0V GND 0V GND 0V

    2 To External antenna

    TX1

    To External antenna

    TX1

    To External antenna

    TX1

    To External antenna

    TX1

    3 To External antenna

    TX2

    To External antenna

    TX2

    To External antenna

    TX2

    To External antenna

    TX2

    4 To External antenna

    RX1

    To External antenna

    RX1

    To External antenna

    RX1

    To External antenna

    RX1

    5 Card Present No function Card Present No function

    6 Future Future Future Future

    7 Format Selector (+/-) Strap to GND Strap to Pin 10 Strap to +5V

    8 Data 1 No function Clock One Output

    9 Data 0 No function Data Zero Output

    10 LED(LED/BEEPER) Beeper / LED Beeper / LED Beeper / LED

    11 No Connection No Connection No Connection No Connection

    12 RXD TTL RXD No function No function

    13 TXD TTL TXD No function No function

    14 DC Voltage Supply +5V +5V +5V

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    5/12

    STX CMD/STATUS LEN DATA BCC ETX

    VALUE 0x02 0x03

    LENGTH 1byte 1 byte 1 byte LEN bytes 1 byte 1 byteWhen Sent:

    CMD

    When receive:

    STATUS (ok

    or Error)

    UART Protocolsl  Command frame(9600,N,8,1)

    DATA NUM DATA  XOR From STX

    to DATA  Frame endDescription Start Frame

    ID

    1 byte

    Address: 0-255

    Device ID: 0x00—0xff,

    default:0x01

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    6/12

    Function

    Command DATA STAUS DATA Length DATA

    Link 0x00 0x00 Ok=0 0x00

    Err=Other 

    For Example

    Reset 0x01 0x00 Ok=0 0x00

    Err=Other 

    For Example

    Buzzer control 0x03 ABCD OK=0 0x00

     A=0x00 buzzer off Err=other 

     =0x01 buzzer on

     =0x02 buzzer on BCD*10 ms

    BCD: When A=2 the time is given

    by the value BCD

    For example, if the time value is

    123, then B=0x01, C=0x02,

    D=0x03

    0x01,0x00 0x00,0x00

    0x00,0x00 0x00,0x00

     A=0 or 1 : 0x03,0x04,0x00

     A=2 :0x03,0x04,0x02,0x01,0x02,0x030x00,, 0x00,

    0x04 or 0x00

     

    02 01 00 00 03 03

    Send Return

    DATA Length

    CMD/STAUS、DATA LENGTH、DATA

    02 01 03 04 02 00 01 00 07 03 buzzer on for10ms

    02 01 03 04 01 00 00 00 05 03 buzzer on

    02 01 03 04 00 00 00 00 04 03 buzzer off 

    For example:

    02 01 00 00 03 03

    02 01 00 00 03 03

    Command

    Type

    System

    Command

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    7/12

    Function

    Command DATA STAUS DATA Length DATA

    Read EM4001

    compatible format  0xA4   N   0x00 0x05   DDDDD

    N:reading formate   (5 bytes data)

    0:10D

    1: 16H

    Write EM4001

    compatible format0xA5 NUPPPPCHHHHH 0x00 0x00  

    U:=0----password not used

    U:=1----using password

    PPPP: 4 byte password

    C: card type

    C=0 T5557

    C=1 EM4469

    C=2 HITAGS

    HHHHH: 5bytes card data in hex

    02 01 A4 01 01 A7 03

    02 01 A4 01 00 A6 03 read decimal 02 01 00 05 00 01 39 17 74 5D 03

    02 01 03 04 01 00 00 00 05 03 02 01 00 00 03 03

    0x01

    For example:

    02 01 A5 0B 00 00 00 00 00 00 12 34 56 78 90 35 03

    card type: 5557, password not using, hex card number: 12 34 56 78 90

    02 01 00 00 03 03

    reading decimalEM4001

    compatible

    read and

    write

    operating

    command

    0x01

    For example:

    reading HEX

    02 01 00 05 82 00 15 3C 9E 33 03

    Card ID in HEX:8200153C9E

    Send Return

    DATA Length

    Card ID in Decimal:0001391774

    Command

    Type

    Command list for different types card

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    8/12

    Function

    Command DATA STAUS DATA Length DATA

    Read 11784 format card 0xA7   N   0x00 ?   when N=0,

    NNNNNNCCDRRRA

    N:reading method

    when N=1

    N=0: 13 bytes data DDDDDDDDDDDDDDDD

    Varified decimal ASCII data when N=2

    6 bytes national ID DDDDDDDDDD

    2 bytes Country ID

    1 hex data (half byte) Data block

    5 hex data (2.5 bytes)

    reserved

    1byte animal flag

    N=1: 16

    original 128bit data

    Varifying decimal ASCII data when N=2

    6 bytes national ID DDDDDDDDDD

    2 bytes Country ID

    1 hex data (half byte) Data block

    5 hex data (2.5 bytes)

    reserved

    1byte animal flag

    N=2: 10 bytes

    8 bytes data + 2bytes varify data

    0x01

    read with method 2

    02 01 A7 01 01 A4 03

    02 01 00 0C 11 22 33 44 55 68 01 23 00 00 00 10 44 03

    read with method 0

    national id: 11 22 33 44 55 68

    Country ID:01 23

    DATA BLOCK:0

    Reserved :00000

     Animal FLAG:1

    02 01 00 10 00 04 8E 57 74 48 ED 1E 01 02 16 7D 1B 20 40 80 92 03

    16bytes original dataread with method 1

    02 01 A7 01 02 A7 03

    02 01 A7 01 00 A5 03

    Send Return

    For example:

    02 01 00 0A C0 78 A2 21 DA 1E 00 80 A2 B7 63 03

    8 bytes data + 2bytes varifing data

    DATA Length

    Command

    Type

    ISO

    11784/11785

    compatible

    read and

    write

    operating

    command

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    9/12

    Function

    Command DATA STAUS DATA Length DATA

    Write 11784 format card   0xA8   UPPPPCDDDDDDDDDDDDDDDD

    U:=0, password not using

     U =1, use password

    PPPP:4byes password

    C:card type

    C=0 T5557

    C=1 EM4469

    C=2 HITAGS

    DDDDDDDDDDDDDDDD:16bytes 4

    BLOCK card data

    DATA BLOCK:0

    For example:

    02 01 A8 16 00 00 00 00 00 00 00 2F B1 EA 2E 12 B7 78 80 40 6D 7F 08 04 02 01 E7 03 02 01 00 0C 11 22 33 44 55 68 01 23 00 00 00 10 44 03

    Password not using

    T5557

    Read data: 2F B1 EA 2E 12 B7 78 80 40 6D 7F 08 04 02 01

    above data was from below:

    Reserved :00000

     Animal FLAG:1

    national id: 11 22 33 44 55 66

    Country ID:01 23

    ISO

    11784/11785

    compatible

    read and

    write

    operating

    command

    Send Return

    DATA Length

    0x16

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    10/12

    Function

    Command DATA STAUS DATA Length DATA

    Initialize card 0xA0   BUPPPPDDDD   0x00 0x00   0x00

    B: blocknumber=0

    U:=0, password not using

     U =1, use password

    PPPP:4byes password

    DDDD:4byes data

    Read data 0xA1   B:   0x00 ?   4*N

    B: block number=1--7 N = total block qty

    4 bytes data

    Changing password   0xA3   BUPPPPDDDD   0x00 0x00

    B: blocknumber=7

    U:=0, password not using

     U =1, use password

    PPPP:4byes password

    DDDD:4byes data

    reading serial number    0xA6   BUPPPPDDDD   0x00 0x00   DDDDDDDD 8 bytes data

    Send Return

    DATA Length

     0x0A

    TEMIC

    T5557 

    T5567

    0x01

     0x00

    For example:

    02 01 A6 00 A5 03

    Condition:the card format must be RF/32 MANCHETER

    02 01 00 08 E0 15 01 55 76 77 95 DC E2 03

    8 bytes serail number: E0 15 01 55 76 77 95 DC

    For example:

    02 01 A2 0A 01 00 00 00 00 00 11 11 11 11 AA 03

    buzzer off 02 01 00 00 03 03

    BLOCK=1

    Password not using

    Data:11 11 11 11

    Command

    Type

    For example:

    02 01 A3 0A 07 00 00 00 00 00 11 11 11 11 AD 03

    new password:11 11 11 11

    02 01 00 00 03 03

    BLOCK为7

    old password:00 00 00 00

    For example:

    02 01 A0 0A 00 00 00 00 00 00 00 08 80 E8 C9 03 02 01 00 00 03 03

    BLOCK=0

    Password not using

    Data: 00 08 80 E8

    0x0A

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    11/12

    Function

    Command DATA STAUS DATA Length DATA

    Read data   0xB1   BUPPPPN   0x00 0x04 DDDD

    B: blocknumber = 0-15, " 2" not

    allowed to use for B4 bytes data

    U:=0, password not using

    U: =1, using password

    PPPP:4 byes password

    N:

    N=0 read according to RF/64 Manchster 

    N=1 read accord ing to RF/32 B iphse

    format

    Write data   0xB2   BUPPPPN   0x00 0x00

    B: blocknumber = 0-15, " 2" not

    allowed to use for B

    U:=0, password not using

    U: =1, using password

    PPPP:4 byes password

    DDDD:4 byes data

    ReturnCommand

    Type

    Send

    DATA Length

    02 01 00 04 00 01 8C 5F D5 03

    Read block 0

    Condition:the card format must be RF/64 MANCHETER

    0x06

    0x0A

    For example:

    02 01 B1 06 00 00 00 00 00 00 B4 03

    02 01 B2 0A 05 00 00 00 00 00 11 11 11 11 BE 03

    EM4469

    EM4569

    EM4205

    00 00 00 00 00 00

    write BLOCK5 with "11 11 11 11"For example:

  • 8/9/2019 ID-20LF-WR RFID Reader Module Read Write 125KHz LF

    12/12

    Function

    Command DATA STAUS DATA Length DATA

    UID REQUES   0xC0   B   0x00 0x04 UID0+UID1+UID2+UID3

    B=0, standard model 4 bytes data

    B=1,uplevel model

    B=2, fast up level model

    AC SEQUENCE   0xC1  

    SELECT_UID   0xC2   UUUU   0x00 0x03 CON0+CON1+CON2

    U= 4 bytes UID 3bytes control letter 

    For example:

    CHALLENGE   0xC3

    SELECT_QUIET   0xC4

    0xC5 P0x00 0x04 DDDD

    P:1byte page number  4 bytes data

    For example:

    READ_BLOCK 0xC6

    WRITE_PAGE 0xC7PDDDD 0x00 0x00

    P:1byte page number 

    DDDD: 4 bytes data

    WRITE _BLOCK   0xC8

    QUIET   0xC9

    write page 4 data: 11111111For example:

    0x05

    02 01 C7 05 04 11 11 11 11 C5 03 02 01 00 00 03 03

    Command

    Type

    02 01 C5 01 04 C3 03

    02 01 C2 04 D8 C9 7E 72 D8 03 02 01 00 04 C9 24 00 AA 40 03

    0x01

    02 01 00 04 EB FE 00 00 12 03

    READ_PAGE

     

    0x04

    For example:

    02 01 C0 01 00 C2 03 02 01 00 04 D8 C9 7E 72 1A 03

    0x01

    DATA Length

    Send Return

    HITAG-S32

    S256 S2048


Recommended