    III. LOAD EVALUATION

    Load classification:

    a)Permanent loads

    -own weight of the structure (slabs, girders,

    columns, roof, walls);

    -earth pressure

    b)Variable loads

    -live loads;

    -snow;

    -wind

    c)Exceptional loads

    -earthquake.

    a) Permanent loads

    The permanent loads are the result of the own weight of

    the structural elements, of the non-structural elements of the

    building and of other loads having a permanent action: earth

    pressure.

    The own weight of the elements are computed by

    multiplying the volume of the element with the specific weight of

    the material they are made of.

  • 8/11/2019 III. Load Evaluation - Done

    2/12

    1.Superior floor slab

    No. LayerThickness

    [m]

    Specific

    weight

    [daN/m3]

    n

    Load value

    [daN/m2]

    characteristic design

    1 Plaster 0.01 1900 1.35 19 25.65

    2 RC slab 0.10 2500 1.35 250 337.5

    3 Blinding concrete 0.02 2100 1.35 42 56.7

    4 Thermoinsulation 0.12 130 1.35 15.6 21.06

    5 Protection layer 0.03 2100 1.35 63 85.05

    Total 389.6 524.96

  • 8/11/2019 III. Load Evaluation - Done

    3/12

    2. Current foor slab

    i) warm foor

    No. LayerThickness

    [m]

    Specific

    weight

    [daN/m3]

    n

    Load value

    [daN/m2]

    characteristic design

    1 Parquet 0.01 73 1.35 0.73 0.99

    2 Leveling concrete 0.04 2100 1.35 84 113.4

    3 RC slab 0.10 2500 1.35 250 337.54 Plaster 0.01 1900 1.35 19 25.65

    Total 353.73 477.54

    ii) cold floor

    No. LayerThickness

    [m]

    Specific

    weight

    [daN/m3]

    n

    Load value

    [daN/m2]

    characteristic design

  • 8/11/2019 III. Load Evaluation - Done

    4/12

    1 Tile 0.01 1900 1.35 19 25.65

    2 Leveling concrete 0.04 2100 1.35 84 113.4

    3 RC slab 0.10 2500 1.35 250 337.5

    4 Plaster 0.01 1900 1.35 19 25.65

    Total 372 502.2

    iii) circulated terrace

    No. LayerThickness

    [m]

    Specific

    weight

    [daN/m3]

    n

    Load value

    [daN/m2]

    characteristic design

    1 Plaster 0.01 1900 1.35 19 25.652 RC slab 0.10 2500 1.35 250 337.5

    3 Leveling concrete 0.03 2100 1.35 63 85.05

    4 Thermoinsulation 0.12 200 1.35 24 32.4

    5 Sand 0.03 1600 1.35 48 64.8

    6 Mosaic plates 0.03 2000 1.35 60 81

    Total 464 626.4

    iv) non-circulated terrace

  • 8/11/2019 III. Load Evaluation - Done

    5/12

    No. LayerThickness

    [m]

    Specific

    weight

    [daN/m3]

    n

    Load value

    [daN/m2]

    characteristic design1 Plaster 0.01 1900 1.35 19 25.65

    2 RC slab 0.10 2500 1.35 250 337.5

    3 Leveling concrete 0.03 2100 1.35 63 85.05

    4 Thermoinsulation 0.12 200 1.35 24 32.4

    5 Clay slate 0.06 2800 1.35 168 226.8

    Total 524 707.4

    3.Stairs

    No. Layer Thickness

    [m]

    Specific

    weight

    n Load value

    [daN/m2]

  • 8/11/2019 III. Load Evaluation - Done

    6/12

    [daN/m3] characteristic design

    1 Tile 0.01 1900 1.35 19 25.65

    2 RC steps 0.07 2400 1.35 168 226.8

    3 RC ramp 0.10 2500 1.35 250 337.5

    4 Plaster 0.015 1900 1.35 28.5 38.48Total 465.5 628.43

    4.Exterior walls

    No. LayerThickness

    [m]

    Specific

    weight

    [daN/m3]

    n

    Load value

    [daN/m2]

    characteristic design

    1 Plaster 0.015 1900 1.35 28.5 38.48

    2Light Weight

    Concrete0.25 600 1.35 150 202.5

    3 Thermoinsulation 0.1 200 1.35 20 27

    4 Plaster 0.015 1900 1.35 28.5 38.48

    Total 227 306.46

    5.Dividing walls

  • 8/11/2019 III. Load Evaluation - Done

    7/12

    No. LayerThickness

    [m]

    Specific

    weight

    [daN/m3]

    n

    Load value

    [daN/m2]

    characteristic design

    1 Plaster 0.015 1900 1.35 28.5 38.48

    2 Brick masonry 0.10 1800 1.35 180 243

    3 Plaster 0.015 1900 1.35 28.5 38.48

    Total 237 319.96

    Surface loads transformation into linear distributed loads:

    Structural elementLoad on

    m2

    H

    [m]

    Load on

    m

    Exterior walls 306.46 2.85 873.42

    Dividing walls 319.96 2.85 911.89

    b) Variable loads

    1.Live loads

  • 8/11/2019 III. Load Evaluation - Done

    8/12

    Element n

    Load value

    [daN/m2]

    characteristic design

    Superior slab 1.5 75 112.5

    Current floor 1.5 300 450

    Circulated terrace 1.5 400 600

    Stairs 1.5 400 600

    2.Snow load

    = k i e t 0,ks c c s = =0.811200 160daN/m2; n=1.5;

    sd= kns 1.5160 240 = = daN/m2

    i- shape coefficient;i= 0.8;

    ce- exposure coefficient due to the site of the construction; ce=1;

    ct- thermal coefficient; ct=1;

    s0,k characteristic value of snow load on the soil; s0,k= 200

    daN/m2;

    sk- characteristic value of snow load;

    sd- design value of snow load.

    c) Exceptional loads

    i) Seismic action evaluation according to P100 2006:

    In the modal computation, the seismic action si evaluated using

    the response spectra corresponding to horizontal unidirectional ground

    movements, described by accelerograms. The seismic action is described

    using two horizontal components evaluated starting from the same

    design response spectrum.

  • 8/11/2019 III. Load Evaluation - Done

    9/12

    When a spatial model is used, the seismic action is applied on all

    relevant horizontal directions, and on the central principal directions.

    For the buildings with structural elements on two normal directions,

    these directions are considered relevant.

    In the computation, only the vibration modes with a significant

    contribution to the total seismic response will be conisdered. This

    condition is fulfilled if:

    the sum of the effective modal masses for the considered

    modes of vibration is at least 90% from the total mass of the

    structure;

    all modes of vibration with an effective modal mass greater

    than 5% of the total mass have been considered.

    The shear force applied at the base of the building on the direction

    of the seismic action:

    b i dF S(T)m=

    where:

    i= 1.00 the building is clasified as an importance class III;

    Sd(T) the ordinate of the design response spectrum corresponding

    to the fundamental period T;

    T the fundamental period of vibration in the plane of the

    horizontal direction considered;

    m the total mass of the building;

    = 0.85 the correction factor which takes into account the

    contribution of the fundamental mode of vibration through the effective

    modal mass associated;

    ( )d g

    TS(T) a

    q

    =

  • 8/11/2019 III. Load Evaluation - Done

    10/12

    ag= 0.28g the ground acceleration;

    Tc= 1.00 s the corner period;

    u

    1

    5q

    =

    the behaviour factor of the structure (H ductility class);

    u

    1

    1.35;

    =

    (T) elastic normalised response spectrum for Tc=1.0 s

    The mass on each level is computed using the software Robot

    Millenium.

    ii) Combination of the modal responses

    The modal responses for two consecutive vibration modes, k and

    k+1 are considered independent if their periods of vibration Tkand Tk+1

    (where Tk+1Tk) satisfy the condition: Tk+10.9Tk.

    For the maximum independent modal responses, the total

    maximum effect is obtained using the modal composition relation:

    2

    E E,kE E=

  • 8/11/2019 III. Load Evaluation - Done

    11/12

    where:

    EE the effect of seismic action (internal force, displacement);

    EE,k the effect of the seismic action in mode k.

    If the modal responses are not independent, other means of

    combining the effects of seismic action for each mode of vibration will be

    considered. (complete quadratic composition etc.).

    iii) The spatial modal computation

    In the case of buildings with a non-uniform distribution structural

    elements masses and stiffness, the design will be made using a spatial

    model of the structure. The seismic movement described in the design

    response spectrum must be considered along at least two directions. The

    main action directions are defined by the direction of the resultant of the

    base seismic force from the first mode of vibration and the normal to this

    direction. The response of the structure may be obtained by composing

    the responses along these two directions.

    iv) Hypothesis for design of structures with floors undeformable in

    their own plane

    The influence of the vertical component of the seismic

    movement is neglected;

    The seismic action is represented by the ground movement

    along one of the principal directions x or y or along any other direction in

    the horizontal plane;

    For each level, the centres of mass and the centre of stiffness

    are different, and they may or may not be on the same vertical line;

    In the centre of mass of each floor, three DDOFs are

    considered: two translations, uxand uyand a rotation about the vertical

    axis, u.