Image H 3.7 in x W 10.8 in (H 9.4 cm x W 27.53 cm) Draeger Marine Chemist Association Your Safety is Our Passion August 4, 2015 – Andy Scanlan
Transcript

ImageH 3.7 in x W 10.8 in

(H 9.4 cm x W 27.53 cm)

Draeger Marine Chemist Association

Your Safety is Our Passion

August 4, 2015 – Andy Scanlan

Draeger Background

Marine Chemists | Andy Scanlan | 8/4/20152 | 4

Sensor Technology

Draeger Makes All of It’s Sensors

•Draeger Sensor technology means less long-term drift and fewer calibrations – 6 Month Calibration Schedule

•“Inside the sensor” temperature compensation results in less temperature drift – The 3 Electrode Patent produces and off gas which means less likelihood of poisoning and faster recovery

•Patented “seamless” sensor housing technology eliminates electrolyte leakage, even when sensor is damaged

•Sensor technology means that the sensors are truly smart including complete calibration and setup information - Up to 5 Year Warranties

•Draeger’s patented Three-Electrode Technology maximizes response to the gas of concern and minimizes the response to other chemicals.

Title of presentation | Author of presentation | 05/01/20103 | 4

Sensor Technology

When it is all said and done it is the sensors that get workers home

safely to their families at the end of the day!

Title of presentation | Author of presentation | 05/01/20104 | 4

Marine Chemists | Andy Scanlan | 8/4/20155 | 4

Fastest Reaction Sensors on the Market

H2S Response Time

6 | …

Overview portable Gas Detection

Marine Chemists | Andy Scanlan | 8/4/2015

5 Year Sensor Warranty – O2, H2S, and CO 3 Year – LELOption to replace one of the above sensors with SO2 or NO2

Alarms•180* •90 DB•Vibrating

IP 67 Rated

Alarm thresholds be raised or lowered

7 | …

Overview portable Gas Detection

Marine Chemists | Andy Scanlan | 8/4/2015

• IR Sensor cannot be poisoned and work at 0% O2

• Smallest 6 gas instrument• 5 Year Warranty• 43 Different Sensors Available

8 | …

Confined Space Entry with Dräger Pump X-am 1/2/5000

Dräger X-am 2500Applications

• Easy Handling

• Easy to connect the pump without tools and screws

• Pump function automatically starts after inserting the measuring instrument

• Guided Flow-Test

• The guided flow test before every start up always guarantees a fail-safe operation.

• Connecting the sampling hose and filter is very easy by Luer-lock quick release fastener

• Fast change from pump-mode to diffusion-mode

• Easy, one hand operationDräger X-am 2500 for customer | Rüdiger Weich | March 2013

9 | …

Overview portable Gas Detection

Marine Chemists | Andy Scanlan | 8/4/2015

• Pac Single Gas • PAC 3500 2 Year H2S, O2, and CO• PAC 500 2 Year Warranty• PAC 7000 5 Year Warranty

• Variety of Gas such as CL2, HCN, NH3, OV, and many more

Alarm thresholds can be raised or lowered

10 | …

Overview portable Gas Detection – X Dock Calibration System

Marine Chemists | Andy Scanlan | 8/4/2015

• Calibrates/Bumps up 10 instruments at once

• Up to 6 gases or gas mixes• Single and Multi Gas in 1 unit• Charging Function• Stored Data and Unmatched

Reporting• Networkable, Local, or Stand-

Alone• Significant Less Gas Consumption

11 | …

Overview portable Gas Detection – X Dock Calibration System

Marine Chemists | Andy Scanlan | 8/4/2015

• Touch Screen• Dashboard Reporting• E-mail reporting – Events and

Intervals • Automatic Leak Test• Ability to assign devices and track

bump tests, alarms, and skills• Able to download datalogger

12 | …

Overview portable Gas Detection – X Zone

Marine Chemists | Andy Scanlan | 8/4/2015

• Works in conjunction with Multi-Gas Instruments

• Closed Network for 16 Units – 25 in an open network

• Bluetooth• Integrated Pump allows for

continuous confined space monitoring from up to 150’ – 120 hours

• 360* Gas Entry• Red and Green Flashing Alarms @

108Db

X-AM 7000

Title of presentation | Author of presentation | 05/01/201013 | 4

• PID for VOC’s• Up to 5 Gases• 10.6 Volt Lamp

There will be a new product launch in a PID in late 2016 or early 2017. A special focus will be paid to the size and benzene and other VOC’s. So the above product will become old technology.

Dräger Saver CF (N)The Product

| Ready for Escape | Paul Hatala | FEB201514 | --

Automatic Activation on opening

Easy to see orange hood, with elasticated neck seal

Photo luminescent panels to ensure user can be seen in dark environments

Pressure indicator easily viewed and protected in bag

NIOSH, TC, ABS and SOLAS approvals - meaning Saver can be used on and off shore

5, 10 and 15 min options

Natural rubber neck seal

Inner mask to minimise CO2 build up

Pictograms on lid

Dräger Saver CF (N) Key Criteria

Low cost of ownership

• Requires no service or maintenance for the first 10 years•Transparent window on case allows cylinder pressure gauge to be easily checked without unpacking

Compact Design

•Freedom or movement and storage

•Easily wall mounted, negating the use of wall box making emergency use even less intrusive

Simple Activation

•Opening the carry system instantly activates the Saver. It can be easily reset in the event of a false alarm

Easy of use

•Suitable for untrained personnel, including with glasses and facial hair

| Ready for Escape | Paul Hatala | FEB201515 | --

PARAT Escape HoodsWhen every second counts…

Parat NG

Exhalation valveDirectly leads the exhaled air out of the half mask

Clearly visible hood Hood in signal color for high visibility

Internal head harness Thanks to the automatically adjusting internal head harness, the mask automatically adjusts to any face.

High-performance filterFilter expiration date is clearly marked; the filter is automatically released from the packaging when opened.

Textile neck seal Flexible textile neck seal, alternatively. Parat 7500 is available with an elastomeric neck seal for an even higher protection level

Overall protection 16 years of total service life (provided the filter is exchanged after 8 years.), Hood provides respiratory and eye protection Clear view Wide field of vision due to a panoramic visor. A special anti-fog coating maintains clear vision.

Good fit Specially designed half mask fits a wide variety of face shapes and sizes

Breakthrough Times

Title of presentation | Author of presentation | 05/01/201018 | 4

Gas Concentration Time (minutes)Cyclohexane (C6H12) 2,500 15Chlorine (Cl2) 2,500 15Hydrogen sulfide (H2S) 2,500 15Hydrogen cyanide (HCN) 2,500 15Sulphur dioxide (SO2) 2,500 15Ammonia (NH3) 2,500 15Hydrogen sulfide (H2S) 10,000 5Carbon monoxide (CO) 2,500 15Acrolein (C3H4O) 100 15Hydrogen chloride (HCI) 1,000 15

What is Important to the Marine Industry

• Draeger is committed to the safety of all industries and have developed application multiple application driven products that safety professionals need!

• How can Draeger help make your job easier?

Marine Chemists | Andy Scanlan | 8/4/201519 | 4