2015 PRODUCT CATALOG
HEXAGONAL CONNECTION
2 www.idisystem.eu
TABLE OF CONTENTS /
06
MORSE TAPER CONNECTION
IDBIO® Range Presentation .............................................. 08 IDBIO® surgical protocol ...................... 10 Ø3,5 IDBIO® Implant ................................ 11 Fixed prosthesis Removable prosthesis Ø4 IDBIO® Implant ..................................... 15 Fixed prosthesis Removable prosthesis Ø5 IDBIO® Implant ...................................... 19 Fixed prosthesis Removable prosthesis
IDMAX® Range Presentation .............................................. 26 IDMAX® surgical protocol ..................... 28 Ø4,4 IDMAX® Implant ................................ 29 Fixed prosthesis Removable prosthesis Ø5 IDMAX® Implant ................................... 33 Fixed prosthesis Removable prosthesis Ø6,6 IDMAX® Implant ............................... 37 Fixed prosthesis Removable prosthesis
IDOT Range Presentation .............................................. 44 IDOT surgical protocol .......................... 46 Ø4,4 IDOT Implant .................................... 47 Fixed prosthesis Removable prosthesis Ø5 IDOT Implant ........................................ 51 Fixed prosthesis Removable prosthesis
IDALL® Range Presentation .............................................. 58 IDALL® surgical protocol ...................... 60 Ø4,2 IDALL® Implant ................................ 61 Fixed prosthesis Removable prosthesis Drill set for IDALL® implants ................. 66 Ø5,2 IDALL® Implant ................................ 67 Fixed prosthesis Removable prosthesis
IDCAM® Range Why changing for IDCAM® ? ............. 74 Presentation of the IDCAM® S ........... 76 Presentation of the IDCAM® M ......... 78 IDCAM® surgical protocol ..................... 80 IDCAM® S and M implants ..................... 81 Prosthetic approach ........................... 82 Fixed prosthesis Removable prosthesis
IMPLANT RANGE & Prosthetic Systems
07
25
43
57
73
IDI IMPLANTS DIFFUSION INTERNATIONAL 3
PRESENTATION
04 IDI, since 1987 05 Our Quality commitment24 IDI globally42 The sales team56 The Research & Development department72 The IDI communication
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
FOCUS ON PROSTHETICS Zirconia ......................................................... 23 Transgingival Titan kits ........................ 41 IDLoc .............................................................. 55 IDUnit .............................................................. 90 General prosthetic approach ........ 91
RBS® SURGICAL SETS IDCAM/BIO .......................................................... 94 The RBS® C tapered drills RBS® ................................................................. 96 The RBS® cylindrical drills
OSTEOSINUS Osteosinus set ........................................... 101 Osteosinus .................................................... 102 Rectisinus ...................................................... 102 Angulosinus ................................................. 103 Forsinus ........................................................... 103 Trepanosinus .............................................. 104 Diskosinus ...................................................... 104 Procedure for Trepanosinus ............ 105 Procedure for Forsinus ........................ 107
ACCESSORIES AND RELATING INSTRUMENTS Ridge spreading condensing ......... 108 Trephines ...................................................... 108 Ratchets ........................................................ 109 Thread tap .................................................. 109 Screwdrivers ............................................... 109 Instruments .................................................. 109
Packaging of IDI implants ..................... 110
Read more about our General terms and conditions of sale on our website: www.idisystem.eu
93
99
108
Products featured in our catalog are medical devices restricted to health professionals.
Since 1987SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
“WE DEVELOP AND MANUFACTURE IN FRANCE”
Since 25 years, IDI firm (Implants Diffusion International), in collaboration with a team of researchers, engineers and dental surgeons, has regularly developped new products intended to implantology.
Implants Diffusion International invests a great deal in the research of new technologies such as RBS® drill, state of surface SMA +Tio2,
Osteosinus…
The IDI lines are developed and manufactured in the Paris region, France by professionals fully com-mitted to meet the practitioners expectations. IDI applies a strict Quality policy to each manufac-turing step. The IDI company is certified according to the applicable standards: ISO 13485, ISO 9001,
CE, TCP, FDA, CMDCAS by SGS.
The IDBIO® range was successfully launched in 2011 and was quickly appreciated by practitioners all over
the world.
The next decade will see the launching of numerous innova-tions emerging from our Research and Development Department.
Gérard Boukhris - President
SCC AccreditedCB
TaiwanTaiwanT
4 www.idisystem.eu
The IDI teams, concerned with the trust relationship that they enter into with the practitioners, decided to offer lifetime warranties to all the implant lines of the IDI brand.
Proud of our implant quality, we supply an accurate customer service to assist you in your daily practice in order to meet your highest requirements. The “General conditions” and the warranty protocol may be downloaded from the www.idisystem.fr website, section: Documentations/Quality.IDI put the customer relationship at the heart of its concerns every day. The IDI teams are regularly trained in the latest cutting-edge techniques and in all the products necessary to the implantologists.
Our product Quality is a key asset to a stress-free practice.
THE QUALITY COMMITMENT OF THE IDI COMPANY / THE LIFETIME WARRANTY
IDI IMPLANTS DIFFUSION INTERNATIONAL 5
Important considerations about IDI SystemTightening torques
PRODUCTS Values(Ncm)
Comments
Implants ≤75 Use the ratchetClosing cap 5 to 10
Use the manual screwdriver*
Healing cap 5 to 10IDUnit : abutment 25IDUnit : retaining screw 15Retaining screw 25Manual screwdriver 5 to 25Screwdriver with dental shank 25 Use the contra angle or the torque wrench*
* Distortion of the screwdriver at 45Ncm to preserve the implant.
!
IDI - Implants Diffusion International - develops, manufactures and distributes the largest range of dental implants all over the world, as well as implantology and dental surgery equipment. IDI products are manufactured in France exclusively. They’re resulting from the essential work of the Research and Development Department. For IDI, to be close to practitioners, hospitals and implantology training centres is a great deal, because they take part to the constant innovation.
Implant range and prosthetic systems
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
HEXAGONAL CONNECTION /
IDBIO®
IDMAX®
IDOT
MORSE TAPER CONNECTION /
IDALL®
IDCAM®
SURGICAL SETS
PACKAGING OF IDI IMPLANTS
07
57
93110
6
HEXAGONAL CONNECTION
IDBIO® / Range
“The profile of the IDBIO® implant is inspiring numerous brands. The association between this profile and a stabilized internal hexagonal connection gives me entire satisfaction.”
Dr Justine B. (Belgium)
7
8 www.idisystem.eu
Range IDBIO® /PRESENTATIONThe internal conception of the IDBIO® implant significantly improves the stabilization of the prosthetic reconstructions thanks to its GSP® connection (Groove for Prosthetic Stabilization).
The IDBIO® benefits from the S.M.A sandblasted, acid-etched and TiO2 coated state of surface, from a two-phase Ti6Al4V grade 5.The IDBIO® implant draws special attention to itself thanks to its square and V shaped threads and thanks to its anchorage for prosthetic stabilization.This self-condensing implant stands 75 N.cm screwing stress without being affected.
This implant draws special attention to itself due to its hexagonal prosthetic anchorage and its cylindro-tapered shape like a dental root. Its cylindrical shape at the level of the implant neck reduces the tension at the level of the crestal bone. Its conical shape allows a better insertion between the adjacent teeth. The angulation, the space and the depth of the threads were specially studied to optimize the stabilization in any bone density and favor the immediate loading.Its aggressive apex enables efficient primary catch.
Self-drillinglow threads
Condensinghigh threads
Anti-unscrewinggroove
Anchorage compatible with IDI
Anchorage of prosthetic stabilization
Hexagonal prosthetic anchorage
Internal universal ISO thread
Instructions for use:1. Use the screwdriver P/N 0146,
1046, 0046, 0846 to screw the implant.
2. Use the screwdriver P/N 0014, 1014, 1114, 0114 to screw the cover screw manually at 5 N.cm while omitting the hinged ratchet.
Features of the IDBIO® implant:– Cylindro-tapered-shaped
– Titanium alloy two phase Ti6Al4V grade 5
– S.M.A. TiO2 state of surface
– Hexagonal connection
– Anti-unscrewing groove
– Progressive and condensing threads
– Penetrating apex
IDI IMPLANTS DIFFUSION INTERNATIONAL 9
IDB
IO®
Non
con
tract
ual p
ictu
res
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
HEXAGONAL CONNECTION
THE
IMPL
AN
TS
LIN
ES
Ø 3,5 mm
Ø 4 mm
Ø 5 mm
Ø 3,5 mm
Ø 4 mm
Ø 5 mm
Ø 3,5 mm
Ø 4 mm
Ø 5 mm
Ø 3,5 mm
Ø 4 mm
Ø 5 mm
IDB 0835
IDB 0840
IDB 0850
IDB 1035
IDB 1040
IDB 1050
IDB 1235
IDB 1240
IDB 1250
IDB 1535
IDB 1540
IDB 1550
IDBIO® IMPLANT RANGEIMPLANT TYPE LENGTH P/N
All the dimensions are in millimeters.
Color code
8
8
10
10
10
12
12
12
15
15
15
8
IDBIO® 3,5
IDBIO® 4
IDBIO® 5
*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® drills for the implants with a hexagonal connection:
8 mm length10 mm length12 mm length15 mm lengthLE
NG
TH 1
0LE
NG
TH 8
LEN
GTH
12
LEN
GTH
15
10 www.idisystem.eu
EXAMPLE OF AN IDBIO® IMPLANT - FOR THE MANDIBULE (example with the implant placement for an IDBIO® implant P/N: IDB1240)
Important considerations about IDBIO®
The Ø 3,5mm IDBIO® implants are reserved for the upper lateral incisors and lower incisors only.
The IDBIO® implants are supplied with a sterile closing cap and a healing cap.To optimize the aesthetic result, it is recommended to set the 1mm implant in a sub-crestal position.
It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the lasting of the prosthesis.
The length choice and implant diameter must be based on the bone density determined by the CT-scan.
!
Ø 3,5 mm
Ø 4 mm
Ø 5 mm
Ø 3,5 mm
Ø 4 mm
Ø 5 mm
Ø 3,5 mm
Ø 4 mm
Ø 5 mm
Ø 3,5 mm
Ø 4 mm
Ø 5 mm
IDB 0835
IDB 0840
IDB 0850
LENGTHDRILL TO US
IDBIO® IMPLANT P/N
Color code*
IDB 1035
IDB 1040
IDB 1050
IDB 1235
IDB 1240
IDB 1250
IDB 1535
IDB 1540
IDB 1550
All the dimensions are in millimeters.
8
8
10
10
10
12
12
12
15
15
15
8
Suture.
Use the 4,2mm diameter drill & 12mm length (P/N 124223). Drill with irrigation at 350 rpm. If drilling procedure with bone harvesting: 100 rpm.
Screw the implant P/N IDB1240:• with the help of a contra-angled handpiece and a screwdriver P/N.:1046 or 1146;• or with the manual screwdriver P/N: 0846.
Finish screwing the paracrestal implant with the screwdriver P/N.:1146 or 1046 and the ratchet P/N.:414
Use the pilot drill P/N.: 1220 of 2mm diameter & 12mm length. Drill at 350 rpm with ample cooling.
Screw the cover screw at 5N.cm with the screwdriver P/N.: 0014 or 0114
Use the 3,5mm diameter drill & 12mm length (P/N 123522). Drill with irrigation at 350 rpm. If drilling procedure with bone harvesting: 100 rpm.
5 6
3
4
21
IDBIO®
SURGICAL PROTOCOL
(Omit this step for an implant placement at the maxilla.)
IDI IMPLANTS DIFFUSION INTERNATIONAL 11
IDB
IO®
Non
con
tract
ual p
ictu
res
Ø 3,
5 MM
3,53,5 Ø 3,5 MM IDBIO® EMERGENCE
Ø3,5 IDBIO® Implants
Length 8 mm - Diameter 3,5 mm IDB 0835
Length 10 mm - Diameter 3,5 mm IDB 1035
Length 12 mm - Diameter 3,5 mm IDB 1235
Length 15 mm - Diameter 3,5 mm IDB 1535
Closing cap
Ø 3,5mm closing cap 1231
Healing cap
Ø 3,5mm IDBIO® healing cap – 2 mm high 1330
Ø 3,5mm IDBIO® healing cap – 4 mm high 1331
Ø 3,5mm IDBIO® healing cap – 6 mm high 1332
12 www.idisystem.eu
Prosthetic components
Ø 3,5 MM EMERGENCE
FIXED PROSTHESIS
Burnout cylinders
Non rotational, incl. retaining screw P/N 1414 356S
Rotational, incl. retaining screw P/N 1414 358S
Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6350H
Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6350R
Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6351H
Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6351R
Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6352H
Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6352R
Gold cylindersCylinder, gold, non rotational to cast on + screw ASH35
Cylinder, gold, rotational to cast on + screw ASR35
Zirconia TiBase
Titan abutment basis + screw 7535
Titan abutments for a temporary toothNon rotational Ø 3,5mm Incl. screw APPH35
Rotational Ø 3,5mm Incl. screw APPR35
Impression cylinders
Rotational, straight (for solidarized elements) 7210
Rotational, conical (for solidarized elements) 7211
Non rotational, closed tray technique (for an unitary implant) 905
Non rotational, pick-up technique, (for an unitary implant) 906
Golden tapped Hexagonal abutmentsStraight Slim abutment for Platform switch + retaining screw P/N 0215
3400G
Abutment, straight + retaining screw P/N 0215 3600G
Abutment, straight, with a 2mm shoulder + retaining screw P/N 0215 3602G
Abutment, straight, with a 4mm shoulder + retaining screw P/N 0215 3604G
Abutment, 15° angled + retaining screw P/N 0215 3615G
Abutment, 23° angled + retaining screw P/N 0215 3623G
Ø 3,5mm Abutment, 0° to 18° + retaining screw P/N 0215 HTU1G
Implant analog
For Ø 3,5mm IDBIO® implant 2335
Retaining screws
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0215
For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414
For prosthesis, short head: ≤ 25N.cm maximum 1413
IDI IMPLANTS DIFFUSION INTERNATIONAL 13
IDB
IO®
Non
con
tract
ual p
ictu
res
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
HEXAGONAL CONNECTION
Ø 3,
5 MM
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U3501
IDUnit attachment, Transgingival height: 2,5 mm U3502
IDUnit attachment, Transgingival height: 4 mm U3504
IDUnit attachment, Transgingival height: 6 mm U3506
17° angled IDUnit attachment (1 mm high) U3521
30° angled IDUnit attachment (1 mm high) U3531
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 00216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
All the dimensions are in millimeters.
14 www.idisystem.eu
Prosthetic components
Ø 3,5 MM EMERGENCE
IDLoc
IDLoc attachments Transgingival height: 1 mm L3501
Transgingival height: 2,5 mm L3502
Transgingival height: 4 mm L3504
Transgingival height: 6 mm L3506
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222351
Transgingival height: 2,5 mm 222352
Transgingival height: 4 mm 222354
Transgingival height: 6 mm 222356
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 935
Magnetic 0940
REMOVABLE PROSTHESIS
IDI IMPLANTS DIFFUSION INTERNATIONAL
IDB
IO®
Non
con
tract
ual p
ictu
res
15
Ø 4
MM
44 Ø 4 MM IDBIO® EMERGENCE
Ø4 IDBIO® Implants
Length: 8mm – Diameter 4,0mm IDB 0840
Length: 10mm – Diameter 4,0mm IDB 1040
Length: 12mm – Diameter 4,0mm IDB 1240
Length: 15mm – Diameter 4,0mm IDB 1540
Closing cap
Ø 4mm IDBIO® closing cap 1241
Healing cap
Ø 4mm IDBIO® healing cap; height: 2mm 1340
Ø 4mm IDBIO® healing cap; height: 4mm 1341
Ø 4mm IDBIO® healing cap; height: 6mm 1342
16 www.idisystem.eu
Prosthetic components
Ø 4 MM EMERGENCE
FIXED PROSTHESIS
Burnout cylinders
Non rotational, incl. retaining screw P/N 1414 456S
Rotational, incl. retaining screw P/N 1414 458S
Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6400H
Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6400R
Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6401H
Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6401R
Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6402H
Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6402R
Gold cylindersCylinder, gold, non rotational to cast on + screw ASH40
Cylinder, gold, rotational to cast on + screw ASR40
Zirconia TiBase
Titan abutment basis + screw 7540
Titan abutments for a temporary toothNon rotational Ø 4mm Incl. screw APPH40
Rotational Ø 4mm Incl. screw APPR40
Impression cylinders
Rotational, straight (for solidarized elements) 7210
Rotational, conical (for solidarized elements) 7211
Non rotational, closed tray technique (for an unitary implant) 905
Non rotational, pick-up technique, (for an unitary implant) 906
Golden tapped Hexagonal abutments
Slim abutment for Platform switch + retaining screw P/N 0215 3800G
Abutment, straight + retaining screw P/N 0215 4000G
Abutment, straight, with a 2mm shoulder + retaining screw P/N 0215 4002G
Abutment, straight, with a 4mm shoulder + retaining screw P/N 0215 4004G
Abutment, 15° angled + retaining screw P/N 0215 4015G
Abutment, 23° angled + retaining screw P/N 0215 4023G
Ø 4mm Abutment, 0° to 18° + retaining screw P/N 0215 HTU2G
Implant analog
For Ø 4mm IDBIO® implant 2340
Retaining screwsGolden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0215
For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414
For prosthesis, short head: ≤ 25N.cm maximum 1413
IDI IMPLANTS DIFFUSION INTERNATIONAL 17
IDB
IO®
Non
con
tract
ual p
ictu
res
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
HEXAGONAL CONNECTION
Ø 4
MM
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U4001
IDUnit attachment, Transgingival height: 2,5 mm U4002
IDUnit attachment, Transgingival height: 4 mm U4004
IDUnit attachment, Transgingival height: 6 mm U4006
17° angled IDUnit attachment (1 mm high) U4021
30° angled IDUnit attachment (1 mm high) U4031
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
All the dimensions are in millimeters.
18 www.idisystem.eu
Prosthetic components
Ø 4 MM EMERGENCE
IDLoc
IDLoc attachments Transgingival height: 1 mm L4001
Transgingival height: 2,5 mm L4002
Transgingival height: 4 mm L4004
Transgingival height: 6 mm L4006
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222401
Transgingival height: 2,5 mm 222402
Transgingival height: 4 mm 222404
Transgingival height: 6 mm 222406
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 941
Magnetic 0940
REMOVABLE PROSTHESIS
IDI IMPLANTS DIFFUSION INTERNATIONAL
IDB
IO®
Non
con
tract
ual p
ictu
res
19
Ø 5
MMØ 5 MM
IDBIO® EMERGENCE
Implants IDBIO® Ø5
Length: 8mm – Diameter 5,0mm IDB 0850
Length: 10mm – Diameter 5,0mm IDB 1050
Length: 12mm – Diameter 5,0mm IDB 1250
Length: 15mm – Diameter 5,0mm IDB 1550
Closing cap
Ø 5mm IDBIO® closing cap 1251
Healing cap
Ø 5mm IDBIO® healing cap; height: 2mm 1350
Ø 5mm IDBIO® healing cap; height: 4mm 1351
Ø 5mm IDBIO® healing cap; height: 6mm 1352
5
20 www.idisystem.eu
Prosthetic components
Ø 5 MM EMERGENCE
FIXED PROSTHESIS
Burnout cylinders
Non rotational, incl. retaining screw P/N 1414 556S
Rotational, incl. retaining screw P/N 1414 558S
Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500H
Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500R
Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501H
Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501R
Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502H
Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502R
Retaining screws
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0215
For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414
For prosthesis, short head: ≤ 25N.cm maximum 1413
Gold cylindersCylinder, gold, non rotational to cast on + screw ASH50
Cylinder, gold, rotational to cast on + screw ASR50
Zirconia TiBase
Titan abutment basis + screw 7550
Titan abutments for a temporary toothNon rotational Ø 5mm Incl. screw APPH50
Rotational Ø 5mm Incl. screw APPR50
Impression cylinders
Rotational, straight (for solidarized elements) 7210
Rotational, conical (for solidarized elements) 7211
Non rotational, closed tray technique (for an unitary implant) 905
Non rotational, pick-up technique, (for an unitary implant) 906
Golden tapped Hexagonal abutments
Slim abutment for Platform switch + retaining screw P/N 0215 3800G
Abutment, straight + retaining screw P/N 0215 5000G
Abutment, straight, with a 2mm shoulder + retaining screw P/N 0215 5002G
Abutment, straight, with a 4mm shoulder + retaining screw P/N 0215 5004G
Abutment, 15° angled + retaining screw P/N 0215 5015G
Abutment, 23° angled + retaining screw P/N 0215 5023G
Ø 5mm Abutment, 0° to 18° + retaining screw P/N 0215 HTU5G
Implant analog
For Ø 5mm IDBIO® implant 2350
IDI IMPLANTS DIFFUSION INTERNATIONAL 21
IDB
IO®
Non
con
tract
ual p
ictu
res
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
HEXAGONAL CONNECTION
Ø 5
MM
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5001
IDUnit attachment, Transgingival height: 2,5 mm U5002
IDUnit attachment, Transgingival height: 4 mm U5004
IDUnit attachment, Transgingival height: 6 mm U5006
17° angled IDUnit attachment (1 mm high) U5021
30° angled IDUnit attachment (1 mm high) U5031
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
All the dimensions are in millimeters.
22 www.idisystem.eu
Prosthetic components
Ø 5 MM EMERGENCE
IDLoc
IDLoc attachments Transgingival height: 1 mm L5001
Transgingival height: 2,5 mm L5002
Transgingival height: 4 mm L5004
Transgingival height: 6 mm L5006
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222501
Transgingival height: 2,5 mm 222502
Transgingival height: 4 mm 222504
Transgingival height: 6 mm 222506
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 951
Magnetic 0940
REMOVABLE PROSTHESIS
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 23
FOC
US O
N
PRO
STHE
TICS
PROSTHETIC REHABILITATION WITH A ZIRCONIA ABUTMENT
ZIRCONIA ABUTMENT SCREW-RETAINED ON TITAN BASIS
Focus on prosthetics ZIRCONIA
Implant analogImpression copying Zirconia abutment basis + screw
Option for the preparation of a fixed prosthesis.
Screw the zirconia abutment with: • a square-tipped instrument with dental shank P/N 1014 or 1114. • or with the screwdriver P/N 0014 or 0114. Screw up to 25N.cm.
Zirconia abutment Performed by the dental lab
24
Since 1987, IDI has an exchange with practitioners and implantologists from all over the world. This is a key element taking part in the implant conception by the R&D department.
A COLLABORATION WITH PRACTITIONERS FROM 30 COUNTRIES /
IDI INTERNATIONALLY
Gérard Boukhris and the Export team daily ensure the right coordination of international activity. The purpose is to guarantee the customer a perfect proximity, reactivity, advice and service quality.
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
www.idisystem.eu
guarantee the customer guarantee the customer a perfect proximity, a perfect proximity, reactivity, advice and
HEXAGONAL CONNECTION
“At the beginning of my activity, I used to work with flared neck cylindro-tapered implants. I tried the IDMAX® implant and I have no regret. Its aesthetic neck allowed me to treat several difficult cases with a low gum height. ”
Dr Marc D. (France)
25
IDMAX® / Range
Range IDMAX® /
26 www.idisystem.eu
Gold-polished aesthetic neck
Penetrating threads
Cylindro-tapered
S.M.A. TiO2 state of surface
Ti6Al4V ELITITANIUM ALLOY
Convex apex
Instructions for use: IDMAX® 41. Last drill in the sequence: diameter
3.5 mm.2. Omit the profile drill stage.3. Use a hexagonal screwdriver P/N
1146, 1046, 0146, 0046 to insert the implant.
4. he IDMAX® 4 type implants can be set using the one-step, the one and half step or the two-step technique.
5. With poorly mineralized bone the last drill is only inserted up to a third of its length.
6. Use the manual thread tap P/N TAR4.
IDMAX® 51. Last drill in the sequence: diameter
4 mm.2. Omit the profile drill stage.3. Use a hexagonal screwdriver P/N
1146, 1046, 0146, 0046 to insert the implant.
4. The IDMAX® 5 type implants can be set using the one-step, the one and half step or the two-step technique.
5. With poorly mineralized bone the last drill is only inserted up to a third of its length.
6. Use the manual thread tap P/N TAR5.
IDMAX® 61. Last drill in the sequence: diameter 5,4
mm.2. Omit the profile drill stage.3. Use a hexagonal screwdriver P/N
1146, 1046, 0146, 0046 to insert the implant.
4. The IDMAX® 6 type implants can be set using the one-step, the one and half step or the two-step technique.
5. With poorly mineralized bone the last drill is only inserted up to a third of its length.
6. Use the manual thread tap P/N TAR6.
HEXAGONAL CONNECTION
THE
IMPL
AN
TS
LINES
IDM
AX
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 27
*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® drills for the implants with a hexagonal connection:
06 mm length08 mm length10 mm length12 mm length15 mm length
Ø 4 mm
Ø 5 mm
Ø 6 mm
Ø 4 mm
Ø 5 mm
Ø 4 mm
Ø 5 mm
Ø 6 mm
Ø 4 mm
Ø 5 mm
Ø 6 mm
Ø 4 mm
Ø 5 mm
Ø 6 mm
IM+ 0840
IM+ 0850
IM+ 0860
IM+ 0640
IM+ 0650
IM+ 1040
IM+ 1050
IM+ 1060
IM+ 1240
IM+ 1250
IM+ 1260
IM+ 1540
IM+ 1550
IM+ 1560
IDMAX® IMPLANT RANGEIMPLANT TYPE LENGTH P/N
All the dimensions are in millimeters.
Color code*
LEN
GTH
8LE
NG
TH 6
LEN
GTH
10
LEN
GTH
12
LEN
GTH
15
8
8
8
10
10
10
12
12
12
15
15
15
6
6
4,44,4 4,94,9 6,66,6
EMERGENCE
28 www.idisystem.eu
Insert the closing cap into the implant and suture.
The implant is covered with a membrane after six weeks if the gum has attained physiological thickness.
Complete the drilling sequence - omitting the profile drill stage, until the required length and diameter are attained.
Insert the implant so that the gold neck remains exposed supracrestally.
3
4
21
Ø 4,1
R 2
0,8
Ø 4,400,50
Ø 4,6
0,8
Ø 4,900,50
R 2,50
0,8
0,50Ø 6,60
Ø 6
R 4IDMAX® 4
IDMAX® 5
IDMAX® 6
SURGICAL PROTOCOL
EXAMPLE OF AN IDMAX® IMPLANT PLACEMENT
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL
IDM
AX
®
29
Ø 4,1
R 2
0,8
Ø 4,400,50
4,44,4
Ø4,4 IDMAX® Implants
Length: 6mm – Diameter 4,4mm IM+ 640
Length: 8mm – Diameter 4,4mm IM+ 840
Length: 10mm – Diameter 4,4mm IM+ 1040
Length: 12mm – Diameter 4,4mm IM+ 1240
Length: 15mm – Diameter 4,4mm IM+ 1540
Closing cap
Ø 4,4mm closing cap 441
Healing cap
Ø 4,4mm cylindrical healing cap; height: 5mm 413
Ø 4,4mm cylindrical healing cap; short head; height: 3,2mm 413C
Ø 4,4mm cylindrical healing cap; long head; height: 6,5mm 413L
Ø 4,4 MM IDMAX® EMERGENCE
Ø 4,
4 M
M
30 www.idisystem.eu
FIXED PROSTHESIS
Burnout cylinders
Rotational incl. retaining screw P/N 914C 418S
Non rotational incl. retaining screw P/N 914C H426S
Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6440H
Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6440R
Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6441H
Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6441R
Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6442H
Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6442R
Retaining screws
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0215
For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414
Gold cylindersCylinder, gold, non rotational to cast on + screw ASH44
Cylinder, gold, rotational to cast on + screw ASR44
Zirconia TiBase
Titan abutment basis + screw 7544
Titan abutments for a temporary toothNon rotational Ø 4,4mm incl. screw P/N 1414 APPH44
Rotational Ø 4,4mm incl. screw P/N 1414 APPR44
Impression cylinders
Rotational, straight (for solidarized elements) 7210
Rotational, conical (for solidarized elements) 7211
Non rotational, closed tray technique (for an unitary implant) 905
Non rotational, pick-up technique, (for an unitary implant) 906
Golden tapped Hexagonal abutments
Abutment, 5° angled + retaining screw P/N 0215
AM 4405G
Abutment, 15° angled + retaining screw P/N 0215
AM 4415G
Abutment, 23° angled + retaining screw P/N 0215
AM 4423G
Ø 4mm, 0-18° + retaining screw P/N 0215 HTU4G
Implant analog
For Ø 4,4mm IDMAX® implant 423
Prosthetic components
Ø 4,4 MM EMERGENCE
All the dimensions are in millimeters.
IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)
HEXAGONAL CONNECTION
IDM
AX
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 31
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U4401
IDUnit attachment, Transgingival height: 2,5 mm U4402
IDUnit attachment, Transgingival height: 4 mm U4404
IDUnit attachment, Transgingival height: 6 mm U4406
17° angled IDUnit attachment (1 mm high) U4421
30° angled IDUnit attachment (1 mm high) U4431
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw Retaining screw; for prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
Ø 4,
4 M
M
32 www.idisystem.eu
IDLoc
IDLoc attachments Transgingival height: 1 mm L4401
Transgingival height: 2,5 mm L4402
Transgingival height: 4 mm L4404
Transgingival height: 6 mm L4406
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222441
Transgingival height: 2,5 mm 222442
Transgingival height: 4 mm 222444
Transgingival height: 6 mm 222446
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 944
Magnetic 0940
REMOVABLE PROSTHESIS
Prosthetic components
Ø 4,4 MM EMERGENCE
All the dimensions are in millimeters.
IDI IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
33
IDM
AX
®
Ø 4,6
0,8
Ø 4,900,50
R 2,50
55
Ø 5 IDMAX® Implants
Length: 6mm – Diameter 5mm IM+ 650
Length: 8mm – Diameter 5mm IM+ 850
Length: 10mm – Diameter 5mm IM+ 1050
Length: 12mm – Diameter 5mm IM+ 1250
Length: 15mm – Diameter 5mm IM+ 1550
Closing cap
Ø 4,9mm closing cap 541
Healing cap
Ø 4,9mm cylindrical healing cap; height: 5mm 513
Ø 4,9mm cylindrical healing cap; short head; height: 3,2mm 513C
Ø 4,9mm cylindrical healing cap; long head; height: 6,5mm 513L
Ø 5 MM IDMAX® EMERGENCE
Ø 5
MM
34 www.idisystem.eu
FIXED PROSTHESIS
Burnout cylinders
Rotational incl. retaining screw P/N 1414 518S
Non rotational incl. retaining screw P/N 1414 H526S
Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500H
Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500R
Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501H
Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501R
Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502H
Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502R
Retaining screws
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0215
For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414
Gold cylindersCylinder, gold, non rotational to cast on + screw ASH50
Cylinder, gold, rotational to cast on + screw ASR50
Zirconia TiBase
Titan abutment basis + screw 7550
Titan abutments for a temporary toothNon rotational Ø 4,9mm incl. screw P/N 1414 APPH50
Rotational Ø 4,9mm incl. screw P/N 1414 APPR50
Impression cylinders
Rotational, straight (for solidarized elements) 7210
Rotational, conical (for solidarized elements) 7211
Non rotational, closed tray technique (for an unitary implant) 905
Non rotational, pick-up technique, (for an unitary implant) 906
Golden tapped Hexagonal abutments
Abutment, 5° angled + retaining screw P/N 0215
AM 5005G
Abutment, 15° angled + retaining screw P/N 0215
AM 5015G
Abutment, 23° angled + retaining screw P/N 0215
AM 5023G
Ø 5mm, 0-18° + retaining screw P/N 0215 HTU5G
Implant analog
For Ø 4,9mm IDMAX® implant 523
Prosthetic components
Ø 5 MM EMERGENCE
All the dimensions are in millimeters.
IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)
HEXAGONAL CONNECTION
IDM
AX
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 35
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5001
IDUnit attachment, Transgingival height: 2,5 mm U5002
IDUnit attachment, Transgingival height: 4 mm U5004
IDUnit attachment, Transgingival height: 6 mm U5006
17° angled IDUnit attachment (1 mm high) U5021
30° angled IDUnit attachment (1 mm high) U5031
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
Ø 5
MM
36 www.idisystem.eu
IDLoc
IDLoc attachments Transgingival height: 1 mm L5001
Transgingival height: 2,5 mm L5002
Transgingival height: 4 mm L5004
Transgingival height: 6 mm L5006
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222501
Transgingival height: 2,5 mm 222502
Transgingival height: 4 mm 222504
Transgingival height: 6 mm 222506
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 951
Magnetic 0940
REMOVABLE PROSTHESIS
Prosthetic components
Ø 5 MM EMERGENCE
All the dimensions are in millimeters.
IDM
AX
®N
on c
ontra
ctua
l pic
ture
s
IDI IMPLANTS DIFFUSION INTERNATIONAL 3737
IDM
AX
®
0,8
0,50Ø 6,60
Ø 6
R 4
6,66,6
Ø 6,6 IDMAX® Implants
Length: 8mm – Diameter 6,6mm IM+ 860
Length: 10mm – Diameter 6,6mm IM+ 1060
Length: 12mm – Diameter 6,6mm IM+ 1260
Length: 15mm – Diameter 6,6mm IM+ 1560
Closing cap
Ø 6,6mm closing cap 641
Healing cap
Ø 6,6mm cylindrical healing cap; height: 2,5mm 613C
Ø 6,6mm cylindrical healing cap; height: 5mm 613
Ø 6,6 MM IDMAX® EMERGENCE
Ø 6
,6 M
M
38 www.idisystem.eu
FIXED PROSTHESIS
Burnout cylinders
Rotational incl. retaining screw P/N 1414 618S
Non rotational incl. retaining screw P/N 1414 H626S
Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500H
Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500R
Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501H
Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501R
Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502H
Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502R
Retaining screws
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0215
For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414
Gold cylindersCylinder, gold, non rotational to cast on + screw ASH60
Cylinder, gold, rotational to cast on + screw ASR60
Zirconia TiBaseTitan abutment basis + screw with Platform switch method 7550
Titan abutments for a temporary toothNon rotational Ø 6,6mm incl. screw P/N 1414 APPH60
Rotational Ø 6,6mm incl. screw P/N 1414 APPR60
Impression cylinders
Rotational, straight (for solidarized elements) 7210
Rotational, conical (for solidarized elements) 7211
Non rotational, closed tray technique (for an unitary implant) 905
Non rotational, pick-up technique, (for an unitary implant) 906
Golden tapped Hexagonal abutments
Abutment, 5° angled + retaining screw P/N 1414
AM 6005
Abutment, 15° angled + retaining screw P/N 1414
AM 6015
Abutment, 23° angled + retaining screw P/N 1414
AM 6023
Ø 5mm, 0-18° + retaining screw P/N 1414 HTU6
Implant analog
For Ø 6,6mm IDMAX® implant 623
Prosthetic components
Ø 6,6 MM EMERGENCE
IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)
HEXAGONAL CONNECTION
IDM
AX
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 39
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5001
IDUnit attachment, Transgingival height: 2,5 mm U5002
IDUnit attachment, Transgingival height: 4 mm U5004
IDUnit attachment, Transgingival height: 6 mm U5006
17° angled IDUnit attachment (1 mm high) U5021
30° angled IDUnit attachment (1 mm high) U5031
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
Ø 6,
6 M
M
40 www.idisystem.eu
IDLoc
IDLoc attachments Transgingival height: 1 mm L5001
Transgingival height: 2,5 mm L5002
Transgingival height: 4 mm L5004
Transgingival height: 6 mm L5006
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222501
Transgingival height: 2,5 mm 222502
Transgingival height: 4 mm 222504
Transgingival height: 6 mm 222506
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 951
Magnetic 0940
REMOVABLE PROSTHESIS
Prosthetic components
Ø 6,6 MM EMERGENCE
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 41
SCREW-RETAINED UNITARY ELEMENT FROM TITAN ELEMENT
Retaining screw
Non rotational burnout element
Screw-retained titan element
FOC
US O
N
PRO
STHE
TICS
PROSTHETIC REHABILITATION WITH A TITAN ELEMENT
Focus on prosthetics TRANSGINGIVAL TITAN KITS
SCREW-RETAINED BRIDGE OR CONNECTOR BAR FROM TITAN ELEMENT
Retaining screw
Non rotational burnout element
Screw-retained titan element
42
Our teams of advisors pay particularly attention to your remarks concerning the use of IDI’s products. They are transmitted to the R&D team in order to satisfy you and to meet your expectations.
To give us your remarks concerning IDI’s products, you can reach our sales department : By phone at : +33 (0)1 48 70 70 48 or by mail to : [email protected]
TRAINING AND EXPERIENCE FEEDBACK /
SALES MANAGEMENT
Frédérique IDI export Manager and Michael IDI France sales manager are managing advisors team close to meet the practitioners expectations.
www.idisystem.eu
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
HEXAGONAL CONNECTION
“I tried several brands and different implants during my career. The IDOT implant is, to my opinion, the ideal one: cylindrical, micro-threaded and aesthetic with a simplified prosthetic system. ”
Dr Eugenio B. (Italy)
43
IDOT / Range
44 www.idisystem.eu
Instructions for use: IDOT 41. Last drill in the sequence: diameter 3.5
mm.2. Use the hexagonal screwdriver P/N 1046
or 1146 or 0146 or 0046 to screw the implant.
3. The IDOT 4 can be set using the one-step, the one and a half step or the two-step technique.
4. With poorly mineralised bone the last drill is only inserted up to a third of its length.
5. Use the manual thread tap P/N Tar4 for highly mineralized bone.
6. Use the screwdriver P/N 403, 403M or 403ML to screw the cover screw and healing screw manually at 5N.cm while omitting the ratchet.
IDOT 51. Last drill in the sequence: diameter 4
mm.2. Use the hexagonal screwdriver P/N
1046 or 1146 or 0146 or 0046 to screw the implant.
3. The IDOT 5 can be set using the one-step, the one and a half step or the two-step technique.
4. With poorly mineralised bone the last drill is only inserted up to a third of its length.
5. Use the manual thread tap P/N Tar5 for highly mineralized bone.
6. Use the screwdriver P/N 403, 403M or 403ML to screw the cover screw and healing screw manually at 5N.cm while omitting the ratchet.
Gold-polished esthetic neck
Mini-threads
Cylindrical
S.M.A. TiO2 state of surface
Ti6Al4V ELITitanium alloy
Convex apex
Range IDOT /
HEXAGONAL CONNECTION
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 45
IDO
T
Ø 4 mm
Ø 5 mm
Ø 4 mm
Ø 5 mm
Ø 4 mm
Ø 5 mm
Ø 4 mm
Ø 5 mm
IDOT 0840
IDOT 0850
IDOT 1040
IDOT 1050
IDOT 1240
IDOT 1250
IDOT 1540
IDOT 1550
IDOT IMPLANT RANGEIMPLANT TYPE LENGTH P/N
All the dimensions are in millimeters.
Color code*
*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® drills for the implants with a hexagonal connection:
08 mm length10 mm length12 mm length15 mm length
LEN
GTH
8LE
NG
TH 1
0LE
NG
TH 1
2LE
NG
TH 1
5
8
8
10
10
12
12
15
15
4,44,4 4,94,9
EMERGENCE
THE
IMPL
AN
TS
LINES
46 www.idisystem.eu
Ø 4
3,85
0,9
Ø 4,400,50
4
R 1,9
0,8
Ø 4
4,50
0,9
Ø 4,900,50
4
0,8
R 2,3IDOT 4
IDOT 5
SURGICAL PROTOCOL
EXAMPLE OF AN IDOT IMPLANT PLACEMENT
Insert the closing cap into the implant and suture.
The implant is covered with a membrane after six weeks if the gum has attained physiological thickness.
Complete the drill sequence - omitting the profile drill stage - until the required length and diameter are attained.
Insert the implant so that the gold neck remains exposed supracrestally.
3
4
21
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 47
IDO
T
Ø 4
3,85
0,9
Ø 4,400,50
4
R 1,9
0,8
4,44,4
Ø4,4 IDOT Implants
Length: 8mm – Diameter 4,4mm IDOT 840
Length: 10mm – Diameter 4,4mm IDOT 1040
Length: 12mm – Diameter 4,4mm IDOT 1240
Length: 15mm – Diameter 4,4mm IDOT 1540
Closing cap
Ø 4,4mm closing cap 441
Healing cap
Ø 4,4mm cylindrical healing cap; height: 5mm 413
Ø 4,4mm cylindrical healing cap; short head; height: 3,2mm 413C
Ø 4,4mm cylindrical healing cap; long head; height: 6,5mm 413L
Ø 4,4 MM IDOT EMERGENCE
Ø 4,
4 M
M
48 www.idisystem.eu
FIXED PROSTHESIS
Burnout cylinders
Rotational incl. retaining screw P/N 1414 418S
Non rotational incl. retaining screw P/N 1414 H426S
Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6440H
Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6440R
Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6441H
Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6441R
Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6442H
Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6442R
Retaining screws
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0215
For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414
Gold cylindersCylinder, gold, non rotational to cast on + screw ASH44
Cylinder, gold, rotational to cast on + screw ASR44
Zirconia abutments
Titan abutment basis + screw 7544
Titan abutments for a temporary toothNon rotational Ø 4,4mm incl. screw P/N 1414 APPH44
Rotational Ø 4,4mm incl. screw P/N 1414 APPR44
Impression cylinders
Rotational, straight (for solidarized elements) 7210
Rotational, conical (for solidarized elements) 7211
Non rotational, closed tray technique (for an unitary implant) 905
Non rotational, pick-up technique, (for an unitary implant) 906
Golden tapped Hexagonal abutments
Abutment, 5° angled + retaining screw P/N 0215
AM 4405G
Abutment, 15° angled + retaining screw P/N 0215
AM 4415G
Abutment, 23° angled + retaining screw P/N 0215
AM 4423G
Ø 4mm, 0-18° + retaining screw P/N 0215 HTU4G
Implant analog
For Ø 4,4mm IDOT implant 423
Prosthetic components
Ø 4,4 MM EMERGENCE
All the dimensions are in millimeters.
IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)
HEXAGONAL CONNECTION
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 49
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U4401
IDUnit attachment, Transgingival height: 2,5 mm U4402
IDUnit attachment, Transgingival height: 4 mm U4404
IDUnit attachment, Transgingival height: 6 mm U4406
17° angled IDUnit attachment (1 mm high) U4421
30° angled IDUnit attachment (1 mm high) U4431
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
Ø 4,
4 M
MID
OT
50 www.idisystem.eu
IDLoc
IDLoc attachments Transgingival height: 1 mm L4401
Transgingival height: 2,5 mm L4402
Transgingival height: 4 mm L4404
Transgingival height: 6 mm L4406
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222441
Transgingival height: 2,5 mm 222442
Transgingival height: 4 mm 222444
Transgingival height: 6 mm 222446
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 944
Magnetic 0940
REMOVABLE PROSTHESIS
Prosthetic components
Ø 4,4 MM EMERGENCE
All the dimensions are in millimeters.
IDI IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
51
Ø 4
4,50
0,9
Ø 4,900,50
4
0,8
R 2,3
55
Closing cap
Ø 4,9mm closing cap 541
Healing cap
Ø 4,9mm cylindrical healing cap; height: 5mm 513
Ø 4,9mm cylindrical healing cap; short head; height: 3,2mm 513C
Ø 4,9mm cylindrical healing cap; long head; height: 6,5mm 513L
Ø 5 MM IDOT EMERGENCE
Ø 5
MM
IDO
T
Ø5 IDOT Implants
Length: 8mm – Diameter 5mm IDOT 850
Length: 10mm – Diameter 5mm IDOT 1050
Length: 12mm – Diameter 5mm IDOT 1250
Length: 15mm – Diameter 5mm IDOT 1550
52 www.idisystem.eu
FIXED PROSTHESIS
Burnout cylinders
Rotational incl. retaining screw P/N 1414 518S
Non rotational incl. retaining screw P/N 1414 H526S
Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500H
Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500R
Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501H
Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501R
Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502H
Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502R
Retaining screws
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0215
For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414
Gold cylindersCylinder, gold, non rotational to cast on + screw ASH50
Cylinder, gold, rotational to cast on + screw ASR50
Zirconia abutments
Titan abutment basis + screw 7550
Titan abutments for a temporary toothNon rotational Ø 4,9mm incl. screw P/N 1414 APPH50
Rotational Ø 4,9mm incl. screw P/N 1414 APPR50
Impression cylinders
Rotational, straight (for solidarized elements) 7210
Rotational, conical (for solidarized elements) 7211
Non rotational, closed tray technique (for an unitary implant) 905
Non rotational, pick-up technique, (for an unitary implant) 906
Golden tapped Hexagonal abutments
Abutment, 5° angled + retaining screw P/N 0215
AM 5005G
Abutment, 15° angled + retaining screw P/N 0215
AM 5015G
Abutment, 23° angled + retaining screw P/N 0215
AM 5023G
Ø 5mm, 0-18° + retaining screw P/N 0215 HTU5G
Implant analog
For Ø 4,9mm IDOT implant 523
Prosthetic components
Ø 5 MM EMERGENCE
All the dimensions are in millimeters.
IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)
HEXAGONAL CONNECTION
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 53
IDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5001
IDUnit attachment, Transgingival height: 2,5 mm U5002
IDUnit attachment, Transgingival height: 4 mm U5004
IDUnit attachment, Transgingival height: 6 mm U5006
17° angled IDUnit attachment (1 mm high) U5021
30° angled IDUnit attachment (1 mm high) U5031
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
REMOVABLE PROSTHESIS
Ø 5
MM
IDO
T
54 www.idisystem.eu
IDLoc
IDLoc attachments Transgingival height: 1 mm L5001
Transgingival height: 2,5 mm L5002
Transgingival height: 4 mm L5004
Transgingival height: 6 mm L5006
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222501
Transgingival height: 2,5 mm 222502
Transgingival height: 4 mm 222504
Transgingival height: 6 mm 222506
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 951
Magnetic 0940
REMOVABLE PROSTHESIS
Prosthetic components
Ø 5 MM EMERGENCE
All the dimensions are in millimeters.
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 55
1 - REMOVE THE HEALING CAPS FROM THE IMPLANTS THANKS TO THE SQUARE-TIPPED SCREWDRIVER (P/N 0014 OR P/N 0114). TAKE THE IMPRESSION WITH THE IMPRESSION COPYINGS ADAPTED TO THE IMPLANT.2 - THE LAB PREPARES THE MASTER MODEL WITH THE CORRESPONDING IMPLANT ANALOGS AND POSITIONS THE APPROPRIATE IDLOC ABUTMENTS.3 - THE LAB TECHNICIAN POSITIONS THE WHITE BLOCK OUT SPACERS ONTO THE IDLOC ABUTMENTS, AND, FIX THE BOX IN THE NYLON RING (MALE PART).4 - THEN THE LAB TECHNICIAN PREPARES THE PROSTHESIS ACCORDING TO THE STANDARD PROCEDURE.
PROTOCOL FOR THE IDLOC PLACEMENT: DIRECT METHOD
1 - AFTER REMOVING THE HEALING CAPS FROM THE IMPLANTS, INSERT THE IDLOC ABUTMENT INTO THE IMPLANT ACCORDING TO THE HEIGHT OF THE GINGIVAL TISSUES. THE ABUTMENT SHALL EMERGE BY 1MM SUB-GINGIVAL ; SCREW IT WITH THE SQUARE-END SCREWDRIVER P/N 0014 OR P/N 0114.
2 - PLACE THE BLOCK OUT WHITE SPACER (SOFT MATERIAL) ON EACH IDLOC ABUTMENT AND FIX THE BOX WITH THE NYLON RING (MALE PART).
3 - MARK THE TOP OF THE BOXES WITH ACRYLIC PEN AND POSITION THE PROSTHESIS ABOVE THEM TO LOCATE THE PARTS TO BE HOLLOWED OUT. THEN, FILL IN THE EMPTIED PARTS WITH AUTO-POLYMERIZING RESIN.
4 - POSITION THE PROSTHESIS IN THE MOUTH AND TIGHTEN IT.- WAIT TILL POLYMERIZING PROCESS IS COMPLETED.- REMOVE THE PROSTHESIS AND THE WHITE SPACERS.- REMOVE THE EXCESS RESIN AND PLACE THE PROSTHESIS BACK IN THE PATIENT MOUTH.
Focus on prostheticsTHE IDLOC
PROTOCOL FOR THE IDLOC PLACEMENT: INDIRECT METHOD
FOC
US O
N
PRO
STHE
TICS
www.idisystem.eu56
With significant advances since 1987 in implantology innovation, IDI is recognized by professionals for its leadership concerning the Research and Development. Its team is in permanent thought with professionals, practitioners, sales and technical teams to finalize new products. The morse taper connection, today considered for its technological advance, is resulting from the collaboration of these teams.
A CONSTANT ADVANCE OF PRODUCTS IN R&D /
RESEARCH AND DEVELOPMENT
The Research and Develoment Department is highly involved in developing new products and is constant improving the range. The R&D uses simulation and 3D imagery techniques. The service also benefits from high technologies equipment to develop products.
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
MORSE TAPER CONNECTION
“I selected this implant because of its specific shape and because of its exceptional selfdrilling performances. The IDALL® eases and secures my surgery. My surgeries become a real pleasure.”
Dr Raphaël B. (France)
57
IDALL® / Range
58 www.idisystem.eu
Range IDALL® /PRESENTATIONThe IDALL® range benefits from the latest technological advance, to be associated with the IDI fundamentals such as the S.M.A. and TiO2 state of surface common to all the implant ranges.
This self-drilling implant stands 75 N.cm screwing stress without being affected.The IDALL® implants draws special attention to itself thanks to its aesthetic gold polished neck, and thanks to its Platform switch that minimizes the bone loss and makes the crest extension being possible.Its design is specially studied to optimize the primary stabilization in any bone density and favor the immediate loading.
Features of the IDALL® implant- Cylindro-tapered shape- Platform switch- Gold neck- Ti6Al4V ELI titanium alloy- S.M.A. and TiO2 coated- Morse taper- Cam connection- Anti-unscrewing groove- Penetrating and condensing threads- Double twist threads- Catch base
Plateform Switch
Penetrating and condensing threads
Double twistthreads
Anti-unscrewing groove
Gold neck
CATCH BASE
There is one drill for each implant length.Sub-crestal Para-crestalSupra-crestal
Depth markings for an implant of 15mm length.
IDI IMPLANTS DIFFUSION INTERNATIONAL 59
MORSE TAPER CONNECTION
THE
IMPL
AN
TS
LIN
ESID
ALL
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
Ø 4,2 mm
Ø 5,2 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 4,2 mm
Ø 5,2 mm
IDA 1042
IDA 1052
IDA 1242
IDA 1252
IDA 1542
IDA 1552
IDA 1842
IDA 1852
IDALL® IMPLANT RANGE
IMPLANT TYPE LENGTH P/N
*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® drills for the implants with a hexagonal connection:
All the dimensions are in millimeters.
Color code*
LEN
GTH
10
LEN
GTH
12
LEN
GTH
15
LEN
GTH
18
10
10
12
12
15
15
18
18
Ø 4,20
0,8
IDALL® 4,2
0,8
Ø 5,20
IDALL®
5,2
10 mm length12 mm length15 mm length18 mm length
All the dimensions are in millimeters.
60 www.idisystem.eu
EXAMPLE OF AN IDALL® IMPLANT SETTING of Ø 4,2mm and 12 mm length (P/N IDA1242)
Use the 4 bladed drill of Ø 3,8mm P/N X1238 (Final drill, soft bone).
Place the IDA1242 implant with the screwdriver P/N 0046 or 1046.
21
FOR THE MAXILLA
Use the 4 bladed drill of Ø 3,8mm P/N X1238.
Use the 4 bladed drill of Ø 4,2mm P/N X1242.
21
Place the IDA1242 implant with the screwdriver P/N 0046 or 1046.
3
FOR THE MANDIBLE
- The rotation speed for all drills is 1 500 rpm with ample cooling with physiological serum.- The four-bladed drills must be used without in and out movments.- The recommended rotation speed to set an implant is 15 rpm.- The insertion torque during the implant setting may be superior to 50 Ncm with a screwdriver P/N 0046 or 0146;- When the implant is placed on soft bone or very poor mineralized bone (Type IV), use the drill whose diameter is lower than the implant one.- Finish tightening the implant with the ratchet P/N 415 and the screwdriver P/N 0046 or 0146.- The placement of implant can be performed with help of the manual screwdriver P/N 0846.- To optimize the aesthetic result, it is recommended to set the 1mm implant in a sub-crestal position.
SURGICAL PROTOCOL
IDA
LL®
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 61
Ø 4,20
0,8
4,24,2
Ø4,2 IDALL® Implant
Length: 10mm – Diameter 4,2mm IDA 1042
Length: 12mm – Diameter 4,2mm IDA 1242
Length: 15mm – Diameter 4,2mm IDA 1542
Length: 18mm – Diameter 4,2mm IDA 1842
Closing cap
Ø 4,2mm closing cap 021201
Healing cap
Ø4,2 mm ( low part) - Ø6 mm (high part) – Heigth: 4 mm 021342
Ø4,2 mm (low part) - Ø6 mm (high part) – Heigth: 6 mm 021343
Ø 4,2 MM IDALL® EMERGENCE
Ø 4
,2 M
M
Healing cap for Platform switch methodTransgingival heigth
screw Ø 3,2mm (low part Ø 3,1mm)
screw Ø 4mm (low part Ø 3,6mm)
screw Ø 5mm (low part Ø 3,6mm)
screw Ø 6mm (low part Ø 3,6mm)
2mm021300 021350
4mm021304 021301 021354 021302
6mm0213 021306 021356 021303
8mm021348 021358 021308
All the dimensions are in millimeters.
62 www.idisystem.eu
Prosthetic components
Ø 4,2 MM EMERGENCE
FIXED PROSTHESIS
Titan abutments for a temporary toothNon rotational Ø 4,2mm incl. screw 2064
Rotational Ø 4,2mm incl. screw 2084
Impression cylinders
Rotational, conical 0220C
Rotational 0221
Non rotational, pick-up technique (with screw) 2004
Non rotational, closed tray technique (with screw) 2004F
Screw-on morse tapered abutmentsAbutment, straigth, with shoulder Transgingival heigth: 1,5mm; incl. screw 420001
Abutment, straigth, with shoulder Transgingival heigth: 2,5mm; incl. screw 420002
Abutment, straigth, with shoulder Transgingival heigth: 3,5mm; incl. screw 420003
Abutment, 15° angled, with shoulder Transgingival heigth: 1,5mm; incl. screw 421501
Abutment, 15° angled, with shoulder Transgingival heigth: 2,5mm; incl. screw 421502
Abutment, 15° angled, with shoulder Transgingival heigth: 3,5mm; incl. screw 421503
Abutment, 23° angled, with shoulder Transgingival heigth: 1,5mm; incl. screw 422301
Abutment, 23° angled, with shoulder Transgingival heigth: 2,5mm; incl. screw 422302
Abutment, 23° angled, with shoulder Transgingival heigth: 3,5mm; incl. screw 422303
Implant analog
IDALL® analog 0224
Titan abutments for platform switch method (Ø3,6)
Straigth, 0° Transgingival heigth: 1,5mm; incl. screw 420011
Straigth, 0° Transgingival heigth: 3,0mm; incl. screw 420012
15° angled Transgingival heigth: 1,5mm; incl. screw 421511
15° angled Transgingival heigth: 3,0mm; incl. screw 421512
23° angled Transgingival heigth: 1,5mm; incl. screw 422311
23° angled Transgingival heigth: 3,0mm; incl. screw 422312
IDA
LL®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 63
Ø 4
,2 M
M
Burnout cylindersRotational, with shoulder incl. retaining screw P/N 0214 2184
Titan transgingival kitsNon rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6420H
Rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6420R
Non rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6421H
Rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6421R
Non rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6422H
Rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6422R
Retaining screwsRetaining screw for IDCAM® and IDALL® ≤ 25N.cm maximum (Screw head: Ø 2,5 mm)
0214
For prosthesis, short head ≤ 25N.cm maximum 0219
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0211
Gold cylindersCylinder, gold, non rotational to cast on + screw - Gold morse taper connection 642
Screw-on abutments Straigth, 0° Transgingival heigth: 1,5mm; incl. screw 420021
Straigth, 0° Transgingival heigth: 3,0mm; incl. screw 420022
15° angled Transgingival heigth: 1,5mm; incl. screw 421521
15° angled Transgingival heigth: 3,0mm; incl. screw 421522
23° angled Transgingival heigth: 1,5mm; incl. screw 422321
23° angled Transgingival heigth: 3,0mm; incl. screw 422322
Zirconia TiBaseTitan abutment basis + screw conical, for lab 7636
Titan abutment basis + screw for lab 7542
Titan abutment basis + screw Platform switch (Ø3,6), for lab 7536
64 www.idisystem.eu
All the dimensions are in millimeters.
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U4201
IDUnit attachment, Transgingival height: 2,5 mm U4202
IDUnit attachment, Transgingival height: 4 mm U4204
IDUnit attachment, Transgingival height: 6 mm U4206
17° angled IDUnit attachment (1 mm high) U4221
30° angled IDUnit attachment (1 mm high) U4231
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
Prosthetic components
Ø 4,2 MM EMERGENCE
IDA
LL®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 65
Ø 4
,2 M
M
IDLoc
IDLoc attachments Transgingival height: 1 mm L4201
Transgingival height: 2,5 mm L4202
Transgingival height: 4 mm L4204
Transgingival height: 6 mm L4206
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222421
Transgingival height: 2,5 mm 222422
Transgingival height: 4 mm 222424
Transgingival height: 6 mm 222426
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 942
Magnetic 0940
All the dimensions are in millimeters.
66 www.idisystem.eu
SURGICAL DRILL SET FOR THE IDALL® IMPLANTS
CONTENTS: 2 pilot drills12 cylindro-tapered drills with 4 bladed edges11 relating instruments
P/N 415
P/N 0114
P/N 406
P/N 1114
P/N 420
P/N 0014
P/N 412
Hand piece screwdriver for prosthetics, length: 30mm
Contra angle screwdriver for prosthetics, length: 30mm
Hand piece screwdriver for screwing the implant, length: 22mm
Ratchet Instrument extension
Implant paralleling help by 3
Depth tester
RANGE OF IDALL® DRILLS
Ø 3,8 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 3,8 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 3,8 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 3,8 mm
Ø 4,2 mm
Ø 5,2 mm
X1038
X1042
X1052
X1238
X1242
X1252
X1538
X1542
X1552
X1838
X1842
X1852
DRILLING LENGTH
DRILLING LENGTHP/N P/N
Color code* Color code*
18
18
18
10
10
10
12
12
12
15
15
15
P/N 1014
Hand piece screwdriver for prosthetics, length: 22mm
P/N 0146 P/N 1146 P/N 0046
Hand piece screwdriver for screwing the implant, length: 30mm
Contra angle screwdriver for screwing the implant, length: 30mm
Hand piece screwdriver for screwing the implant, length: 22mm
P/N 1046
Hand piece screwdriver for screwing the implant, length: 32mm
IDA
LL®
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 67
SURGICAL DRILL SET FOR THE IDALL® IMPLANTS
0,8
Ø 5,20
5,25,2
Ø5,2 IDALL® Implants
Length: 10mm – Diameter 5,2mm IDA1052
Length: 12mm – Diameter 5,2mm IDA1252
Length: 15mm – Diameter 5,2mm IDA1552
Length: 18mm – Diameter 5,2mm IDA1852
Closing cap
Ø 5,2mm closing cap 021202
Healing cap
Ø5,2 mm ( low part) - Ø6 mm (high part) – Heigth: 4 mm 021352
Ø5,2 mm (low part) - Ø6 mm (high part) – Heigth: 6 mm 021353
Ø 5,2 MM IDALL® EMERGENCE
Ø 5
,2 M
M
Healing cap for Platform switch methodTransgingival heigth
screw Ø 3,2mm (low part Ø 3,1mm)
screw Ø 4mm (low part Ø 3,6mm)
screw Ø 5mm (low part Ø 3,6mm)
screw Ø 6mm (low part Ø 3,6mm)
2mm021300 021350
4mm021304 021301 021354 021302
6mm0213 021306 021356 021303
8mm021348 021358 021308
All the dimensions are in millimeters.
68 www.idisystem.eu
Prosthetic components
Ø 5,2 MM EMERGENCE
FIXED PROSTHESIS
Titan abutments for a temporary toothNon rotational Ø 5,2mm incl. screw 2065
Rotational Ø 5,2mm incl. screw 2085
Impression cylinders
Rotational, conical 0220C
Rotational 0221
Non rotational, pick-up technique (with screw) 2004
Non rotational, closed tray technique (with screw) 2004F
Screw-on morse tapered abutmentsAbutment, straigth, with shoulder Transgingival heigth: 1,5mm; incl. screw 420001
Abutment, straigth, with shoulder Transgingival heigth: 2,5mm; incl. screw 420002
Abutment, straigth, with shoulder Transgingival heigth: 3,5mm; incl. screw 420003
Abutment, 15° angled, with shoulder Transgingival heigth: 1,5mm; incl. screw 421501
Abutment, 15° angled, with shoulder Transgingival heigth: 2,5mm; incl. screw 421502
Abutment, 15° angled, with shoulder Transgingival heigth: 3,5mm; incl. screw 421503
Abutment, 23° angled, with shoulder Transgingival heigth: 1,5mm; incl. screw 422301
Abutment, 23° angled, with shoulder Transgingival heigth: 2,5mm; incl. screw 422302
Abutment, 23° angled, with shoulder Transgingival heigth: 3,5mm; incl. screw 422303
Implant analog
IDALL® Analog 0225
Titan abutments for platform switch method (Ø4,2)
Straigth, 0° Transgingival heigth: 1,5mm; incl. screw 420021
Straigth, 0° Transgingival heigth: 3,0mm; incl. screw 420022
15° angled Transgingival heigth: 1,5mm; incl. screw 421521
15° angled Transgingival heigth: 3,0mm; incl. screw 421522
23° angled Transgingival heigth: 1,5mm; incl. screw 422321
23° angled Transgingival heigth: 3,0mm; incl. screw 422322
IDA
LL®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 69
Screw-on abutmentsStraigth, 0° Transgingival heigth: 1,5mm; incl. screw 520021
Straigth, 0° Transgingival heigth: 3,0mm; incl. screw 520022
15° angled Transgingival heigth: 1,5mm; incl. screw 521521
15° angled Transgingival heigth: 3,0mm; incl. screw 521522
23° angled Transgingival heigth: 1,5mm; incl. screw 522321
23° angled Transgingival heigth: 3,0mm; incl. screw 522322
Ø 5
,2 M
M
Burnout cylindersRotational, with shoulder incl. retaining screw P/N 0214 2185
Titan transgingival kitsNon rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6520H
Rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6520R
Non rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6521H
Rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6521R
Non rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6522H
Rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6522R
Retaining screwsRetaining screw for IDCAM® and IDALL® ≤ 25N.cm maximum (Screw head: Ø 2,5 mm)
0214
For prosthesis, short head ≤ 25N.cm maximum 0219
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0211
Gold cylindersCylinder, gold, non rotational to cast on + screw - Gold morse taper connection 652
Zirconia TiBaseTitan abutment basis + screw conical, for lab 7636
Titan abutment basis + screw for lab 7552
Titan abutment basis + screw Platform switch (Ø3,6), for lab 7542
70 www.idisystem.eu
REMOVABLE PROSTHESISIDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5201
IDUnit attachment, Transgingival height: 2,5 mm U5202
IDUnit attachment, Transgingival height: 4 mm U5204
IDUnit attachment, Transgingival height: 6 mm U5206
17° angled IDUnit attachment (1 mm high) U5221
30° angled IDUnit attachment (1 mm high) U5231
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
Prosthetic components
Ø 5,2 MM EMERGENCE
All the dimensions are in millimeters.
IDA
LL®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 71
Ø 5
,2 M
M
IDLoc
IDLoc attachments Transgingival height: 1 mm L5201
Transgingival height: 2,5 mm L5202
Transgingival height: 4 mm L5204
Transgingival height: 6 mm L5206
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222521
Transgingival height: 2,5 mm 222522
Transgingival height: 4 mm 222524
Transgingival height: 6 mm 222526
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 952
Magnetic 0940
72
A particular attention is paid by the communication team to improve the quality of products’s imagery and to permit professionals to appreciate in an accuracy way the states of surface and the ergonomy of products of our several brands.
IDI equally participates to many conferences and appointments of the profession, in France and internationally.
QUALITY DEVOTED TO THE PRACTITIONER’S SERVICE /
COMMUNICATION
Our communication department develops many mediums to improve and perpetuate the relationship between the IDI departments and dental professionals.
www.idisystem.eu
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IDCAM® / Range
MORSE TAPER CONNECTION
“On a surgical aspect, IDCAM® implants are easier and more pleasant to place comparing to other implants. Furthermore, with RBS® drills, we can harvest a great quantity of bone. On a prosthetic aspect, at this time I just have used the kit C for unit implants, and I think that’s an excellent one”
Dr Riad M. (Syria)
73
74 www.idisystem.eu
WHY CHANGING FOR IDCAM® ?
WHY IDCAM® ?– For Technology and Innovation – For the IDCAM ® Concept– For the price
Its alloy - Two phases Ti6Al4V grade 5 Studies of Buser (2004), Zhao and Schwartz (2005), Carl E Misch.
Its state of surface - Sandblasted and acid-etched and TiO2, Roughness of 1,76μ – Sandblasted and acid-etched, passivated.
Studies of Becker and Coll, Albrektsson and Wennerberg, Wennerberg, Hanson and Norton 2005.
Its shape - Cylindro-tapered.– The cylindrical shape of implant neck reduces the stress
at the level of the crestal bone. – The tapered shape enables a better insertion between
adjacent teeth.Studies: comparative assessment of implant shape (influence of diameter, length and taper on alveolar bone stress).
Its Threads - Squared-shape and V-shape.Studies of Carl E Misch , Bone Miller.
Its Switching cone Studies: Hüzeler M, Fickl S, Zuhr O, wachtel HC in J Oral Maxilofac Surg 2008 Oct 66(10) 2195-6.
Its Morse taper and Cam RetentionStudies: prospective evaluation of 1 920 implants with morse taper connection. Clin Oral Implants Res 2009 Mar, 20(3), 254-61.
IDCAM ® implant has all features approved by the science and more over!
Studies performed by Pr P.E. Crubillé.
There’s more than 1000 brands of dental implants all over the world.
COMPENDIUM OF SCIENCES APPROVED TECHNOLOGIES
Maximal shearing stress
In this tridimensional finite elements study, the shearing force is the same for V-shaped and reverse V-shaped threads. However, the study shows that the squared-shaped thread reduces shearing forces for the same load.
2,00E+07
1,50E+07
1,00E+07
5,00E+06
0,00E+00 Reverse1,43E+07 1,43E+071,03E+07Maximal
shearing
Maximal shearing stress
Squarred V-shapped
IDC
AM
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 75
THE
IMPL
AN
TS
LINES
RADIOGRAPHIC EXAMINATION Implant placement in canvas shapeTechnique of implant placement without any material.Implant pushing the Schneiderian membrane. The CSO® apex allows the realization of low-risk surgery.
Implant : IDCAM®
Reduces the risk of perforating the Schneiderian membrane.
Others Implants The implant perforated the membrane.
Its CSO® apexConcaveThe concave area allows to sustain grafted biomaterials during sinus lift. SafetyThe atraumatic round-shaped end limits the risks of damaging neighbouring tissues. OsseointegrationThe peripheral wedge groove increases the apical bone retention surface.
Internal part of IDCAM®
Cam retention For a better connection accuracy.2,5° Morse taperInternal Universal ISO threading
Groove of IDCAM®
Helicoidal groove for an anti-unscrewing effect of implant. The internal part is the same, whatever the diameter of implant.
Bone density for IDCAM® S
Diameter of Apex : Ø 2,1 mmPhotos : Pr Bravetti.
Type I
Type III
Type II
Type IV
Bone quality classification of Lekholm & Zarb.
Bone quality classification of Lekholm & Zarb.
Bone density for IDCAM® M
Documents given by Pr P. Bravetti, Dean of the Odontologic Faculty of Nancy.
76
Range IDCAM® S /STANDARD
www.idisystem.eu
PRESENTATIONThe IDCAM®S type IM implant line benefits from the SMA + Ti02 state of surface initiated by IDI and used since 1987.This self-condensing implant stands 75 N.cm screwing stress without being affected. The IDCAM®S implant draws special attention to itself due to its Switching Cone neck and to its cylindro-tapered body identical to a dental root.The angulation, the state and the depth of the threads arespecially studied to optimize the primary stabilization in any bone density and favor the immediate loading.
Implant IDCAM®S features- Cylindro-tapered-shaped- 2,5° morse taper- Titanium alloy Ti6Al4V ELI- SMA + Ti02 state of surface- Cam retention- Switching Cone- Anti-unscrewing grooves- Progressive and condensing threads- CSO® apex
Switching Cone
Self-drilling low threads
Condensing high threads
Anti-unscrewing groove
Advantages of the CSO® APEX
CSO®
APEX
The IDCAM® implant draws special attention to themself because of its CSO® apex*.
Its apex has a concave area that acts as a bone reservoir for bone grafting. The atraumatic « Securit » round-shaped end limits the risks of damaging the sinus membrane and the dental nerve. Its peripheral and wedging groove increases the apical bone retention surface.*CSO ® : Concave Securit Osseo-wedging.Maxillary
Mandible
IDI IMPLANTS DIFFUSION INTERNATIONAL 77
MORSE TAPER CONNECTION
THE
IMPL
AN
TS
LINES
IDC
AM
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
non
cont
ract
ual p
ictu
res
*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® conical drills for the IDCAM® implants :
08 mm length10 mm length12 mm length15 mm length
Standard Ø 4,2 mm
Standard Ø 5,2 mm
Standard Ø 3,5 mm
Standard Ø 4,2 mm
Standard Ø 5,2 mm
Standard Ø 3,5 mm
Standard Ø 4,2 mm
Standard Ø 5,2 mm
Standard Ø 3,5 mm
Standard Ø 4,2 mm
Standard Ø 5,2 mm
IDCS 0842
IDCS 0852
IDCS 1035
IDCS 1042
IDCS 1052
IDCS 1235
IDCS 1242
IDCS 1252
IDCS 1535
IDCS 1542
IDCS 1552
IDCAM® S IMPLANT RANGEIMPLANT TYPE LENGTH P/N
Important considerations
The 3,5mm diameter implants must be used only for lower and upper lateral incisors.The 8mm IDCAM® implants do not have any CSO® Apex.
The IDCAM® implants are supplied with a closing and a healing cap.To improve aesthetic quality, it is recommended to position the implant under 1mm of the bone crest.
It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the lasting of the prosthesis.The length choice and diameter of implant must be based on the bone density determined by the CT- scan.
!
All the dimensions are in millimeters.
Color code*
NB: The 8mm length of IDCAM® implants (P/N IDCS 0842 and IDCS 0852) do not have any CSO® APEX.
LEN
GTH
8LE
NG
TH 1
0LE
NG
TH 1
2LE
NG
TH 1
5
8
8
10
10
10
12
12
12
15
15
15
Ø 3,7
3,60
0,8
Ø 4,20
Ø 3,60
0,8
Ø 5,20
Ø 3,60
0,8
IDCAM® S 3,5
IDCAM® S 4,2
IDCAM® S 5,2
78 www.idisystem.eu
Range IDCAM® M /MINI-THREADS
PRESENTATIONThe IDCAM®M type IM implant line benefits from the SMA + Ti02 state of surface initiated by IDI and used since 1987.This self-condensing implant stands 75 N.cm screwing stress, without being affected.The IDCAM®M implant differentiates from the IDCAM®S because of its mini threads neck, which favor immediate loading.
Implant IDCAM®M features- Cylindro-tapered-shaped
- 2,5° morse taper
- Titanium alloy Ti6Al4V ELI
- SMA + Ti02 state of surface
- Cam retention
- Switching Cone
- Anti-unscrewing grooves
- Mini threads
- Progressive and condensing threads
- CSO® apex
Instructions for use1. Use the screwdriver P/N 0146, 1046,
0046, 0846 to screw the implant.2. Use the screwdriver P/N 0014, 1014,
1114, 0114 to screw the cover screw manually at 5N.cm while omitting the hinged ratchet.
Switching Cone
Self-drilling low threads
Condensing mini threads
Condensing high threads
Anti-unscrewing groove
CSO®
APEX
Morse taper and identical connection for all IDCAM® range.
2,5° morse taper
Cam connection
Internal universal thread ISO
IDI IMPLANTS DIFFUSION INTERNATIONAL 79
MORSE TAPER CONNECTION
THE
IMPL
AN
TS
LINES
IDC
AM
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
non
cont
ract
ual p
ictu
res
*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® conical drills for the IDCAM® implants :
08 mm length10 mm length12 mm length15 mm length
Mini-threads Ø 4,2 mm
Mini-threads Ø 5,2 mm
Mini-threads Ø 4,2 mm
Mini-threads Ø 5,2 mm
Mini-threads Ø 4,2 mm
Mini-threads Ø 5,2 mm
Mini-threads Ø 4,2 mm
Mini-threads Ø 5,2 mm
IDCM 0842
IDCM 0852
IDCM 1042
IDCM 1052
IDCM 1242
IDCM 1252
IDCM 1542
IDCM 1552
IDCAM® M IMPLANT RANGEIMPLANT TYPE LENGTH P/N
All the dimensions are in millimeters.
Color code*
NB: The 8mm length of IDCAM® implants (P/N IDCS 0842 and IDCS 0852) do not have any CSO® APEX.
LEN
GTH
8LE
NG
TH 1
0LE
NG
TH 1
2LE
NG
TH 1
5
8
8
10
10
12
12
15
15
Important considerations
The 3,5mm diameter implants must be used only for lower and upper lateral incisors.The 8mm IDCAM® implants do not have any CSO® Apex.
The IDCAM® implants are supplied with a closing and a healing cap.To improve aesthetic quality, it is recommended to position the implant under 1mm of the bone crest.
It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the lasting of the prosthesis.The length choice and diameter of implant must be based on the bone density determined by the CT- scan.
!
Ø 4,20
3,60
0,8
Ø 5,20
0,8
Ø 3,60
IDCAM® M 4,2
IDCAM® M 5,2
80 www.idisystem.eu
Important considerations about IDCAM®:The Ø 3,5mm IDCAM® implants are reserved for the upper lateral incisors and lower incisors only.
IDCAM® implants of 8mm length do not have Apex CSO.
The IDCAM® implants are supplied with a sterile closing cap and a healing cap.To optimize the aesthetic result, it is recommended to set the 1mm implant in a sub-crestal position.
It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the lasting of the prosthesis.
The length choice and implant diameter must be based on the bone density determined by the CT-scan.
!
Ø 4,2 mm
Ø 5,2 mm
Ø 3,5 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 3,5 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 3,5 mm
Ø 4,2 mm
Ø 5,2 mm
IDCM & S 0842
IDCM & S 0852
LENGTHDRILL TO USE
IDCAM® P/N
Color code*
IDCS 1035
IDCM & S 1042
IDCM & S 1052
IDCS 1235
IDCM & S 1242
IDCM & S 1252
IDCS 1535
IDCM & S 1542
IDCM & S 1552
All the dimensions are in millimeters.
8
8
10
10
10
12
12
12
15
15
15
IDCAM®
SURGICAL PROTOCOLEXAMPLE OF AN IDCAM® IMPLANT (example with the implant placement for an IDCAM® implant P/N: IDCM1242)
321
5 64
Suture.
Use the 4,2mm diameter drill & 12mm length (P/N 124223). Drill with irrigation at 350 rpm. If drilling procedure with bone harvesting: 100 rpm.
Screw the implant P/N IDCM1242 :• with the help of a contra-angled handpiece and a screwdriver P/N.:1046 or 1146;• or with the screwdriver P/N: 0846.Finish screwing the paracrestal implant with the screwdriver P/N.:1146 or 1046 and the ratchet P/N.:414.
Use the Pilot drill P/N.:1220 of 2mm diameter & 12mm length. Drill at 350 rpm with ample cooling.
Screw the cover screw at 5N.cm with the screwdriver P/N.:0014 or P/N.: 0114.
Use the 3,5mm diameter drill & 12mm length (P/N 123522). Drill with irrigation at 350 rpm. If drilling procedure with bone harvesting: 100 rpm.
(This step is to be performed for an implant placement at the mandibule only.)
IDI IMPLANTS DIFFUSION INTERNATIONAL 81
MORSE TAPER CONNECTION
THE
IMPL
AN
TS
LINES
IDC
AM
®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
non
cont
ract
ual p
ictu
res
IDCAM® RANGES
Closing cap
IDCAM® closing cap 0212
IDCAM® mini-threaded implants
Length 8 - Mini-threaded Ø4,2 mm IDCM 0842
Length 8 - Mini-threaded Ø5,2 mm IDCM 0852
Length 10 - Mini-threaded Ø4,2 mm IDCM 1042
Length 10 - Mini-threaded Ø5,2 mm IDCM 1052
Length 12 - Mini-threaded Ø4,2 mm IDCM 1242
Length 12 - Mini-threaded Ø5,2 mm IDCM 1252
Length 15 - Mini-threaded Ø4,2 mm IDCM 1542
Length 15 - Mini-threaded Ø5,2 mm IDCM 1552
IDCAM® standard implants
Length 8 - Standard Ø4,2 mm IDCS 0842
Length 8 - Standard Ø5,2 mm IDCS 0852
Length 10 - Standard Ø3,5 mm IDCS 1035
Length 10 - Standard Ø4,2 mm IDCS 1042
Length 10 - Standard Ø5,2 mm IDCS 1052
Length 12 - Standard Ø3,5 mm IDCS 1235
Length 12 - Standard Ø4,2 mm IDCS 1242
Length 12 - Standard Ø5,2 mm IDCS 1252
Length 15 - Standard Ø3,5 mm IDCS 1535
Length 15 - Standard Ø4,2 mm IDCS 1542
Length 15 - Standard Ø5,2 mm IDCS 1552
Healing cap for FMCTransgingival heigth
screw Ø 3,2mm (low part Ø 3,1mm)
screw Ø 4mm (low part Ø 3,6mm)
screw Ø 5mm (low part Ø 3,6mm)
screw Ø 6mm (low part Ø 3,6mm)
2mm021300 021350
4mm021304 021301 021354 021302
6mm0213 021306 021356 021303
8mm021348 021358 021308
82 www.idisystem.eu
PROSTHETIC KITS
Implant analog
P/N 0223
Burnout cylinder, rotational
P/N 021801
Burnout connector bar
P/N 0931
Nylon clip
P/N 0025
KIT A – The screw-on burnout elements for any type of prosthetic reconstructions
L N P Q SRetaining
screw
P/N 0214
Contents of kit A
Excluded from Kit A, C or D
Impression cylinder, rotational
P/N 0221
U
Impression cylinder incl. screw, non rotational Pick-up technique
P/N 2004
TNon-rotational, closed tray technique
P/N 2004F
F
Conical rotational
P/N 0220C
W
CONNECTOR BAR WITH SPHERICAL ATTACHMENTS– The impression is taken with the impression cylinders (P/N 0221 or 2004)
– The implant analogs (P/N 0223) are screwed onto the impression cylinders and are plastered over.
P
L
N
PRO
STHE
TIC
CO
MPO
NEN
TSID
CA
M®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 83
CONNECTOR BAR WITH CLIPS– The impression
is taken with the impression cylinders (P/N 0221 or 2004)
– The implant analogs are screwed onto the impression cylinders; the model is plastered over (P/N 0223)
SCREW-ON SOLIDARIZED ABUTMENTS + SOLIDARIZED FRAMEWORK– The impression is taken with the impression cylinders (P/N 0221 or
0221C)
– The model is plastered over
– Conception of the framework with P/N 021801 and 0214
– Realization of the ceramic work on a telescopic framework
Setting
X
U
P
S
L
N
P
L
N
PROSTHETIC KITS
All the dimensions are in millimeters.
84 www.idisystem.eu
KIT C – Fixed screw-on CoNe® for an unitary implant (FMC)
K P LScrew-on machined
abutment 6 P/N*
Retaining screwP/N 0211
Implant analogP/N 0223
Contents of kit C
*Different types of abutments for ø 3,5 implant:
*Different types of abutments for ø 4,2 et 5,2 implants:
- Straight abutment : P/N 3500- 15° angled abutment : P/N 3515- 23° angled abutment : P/N 3523
- Straight abutment : P/N 4200- 15° angled abutment : P/N 4215- 23° angled abutment : P/N 4223
NB: Identical morse taper for every external ø of implants (ø 3,5, ø 4,2, ø5,2).
Abutment remover for tapered implants (IDCAM® and IDALL® product lines)
P/N 0148
X
K
PRO
STHE
TIC
CO
MPO
NEN
TSID
CA
M®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 85
M P LFlat supported abutment
6 P/N*
Retaining screwP/N 0211
Implant analogP/N 0223
Content of kit D
KIT D – Fixed screw-on PLAN® abutments for unitary or multiple implants (FMP)
*Different types of abutments for 1,5 mm transgingival height for all types of implants:
*Different types of abutments for 3,0 mm transgingival height for all types of implants:
- Straight abutment: P/N 420011- 15° angled abutment: P/N 421511- 23° angled abutment: P/N 422311
- Straight abutment: P/N 420012- 15° angled abutment: P/N 421512- 23° angled abutment: P/N 422312
X
Comparison between the CôNe abutment and the PLAN® abutment
PLAN®
Screw-on abutment to 25 N.cm
Position the abutment
Screw the abutment to
25 N.cm
CôNe®
NB: Identical morse taper for every external ø of implants (ø 3,5, ø 4,2, ø5,2).
M
All the dimensions are in millimeters.
86 www.idisystem.eu
PROSTHETIC COMPONENTSFIXED PROSTHESIS
Titan abutments for a temporary toothNon rotational incl. screw 0206
Rotational incl. screw 0208
Impression cylinders
Rotational, conical 0220C
Rotational 0221
Non rotational, pick-up technique (with screw) 2004
Non rotational, closed tray technique (with screw) 2004F
Morse tapered abutments (FMC) with shoulderStraigth, incl. screw Transgingival height: 1,5mm 420001
Straigth, incl. screw Transgingival height: 2,5mm 420002
Straigth, incl. screw Transgingival height: 3,5mm 420003
15° angled, incl. screw Transgingival height: 1,5mm 421501
15° angled, incl. screw Transgingival height: 2,5mm 421502
15° angled, incl. screw Transgingival height: 3,5mm 421503
23° angled, incl. screw Transgingival height: 1,5mm 422301
23° angled, incl. screw Transgingival height: 2,5mm 422302
23° angled, incl. screw Transgingival height: 3,5mm 422303
Implant analog
IDCAM® Analog 0223
Morse tapered abutments (FMC) without shoulderMorse taper abutment, straigth, 0° Width: 3,5mm; incl. screw 3500
Morse taper abutment, straigth, 15° Width: 3,5mm; incl. screw 3515
Morse taper abutment, straigth, 23° Width: 3,5mm; incl. screw 3523
Morse taper abutment, straigth, 0° Width: 4,2mm; incl. screw 4200
Morse taper abutment, straigth, 15° Width: 4,2mm; incl. screw 4215
Morse taper abutment, straigth, 23° Width: 4,2mm; incl. screw 4223
KIT C - Morse tapered CôNe abutments (FMC)
3500 + 0211 + 0223 Kit C300
3515 + 0211 + 0223 Kit C315
3523 + 0211 + 0223 Kit C323
4200 + 0211 + 0223 Kit C400
4215 + 0211 + 0223 Kit C415
4223 + 0211 + 0223 Kit C423
PRO
STHE
TIC
CO
MPO
NEN
TSID
CA
M®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 87
Burnout cylinders
Rotational, with shoulder 021801
Non-rotational, with shoulder in nylon, for temporary tooth 022602
0223 + 0214 + 021801 + 0931 + 0025 Screw-on burnout elements for any type of prosthetic reconstructions
Kit A
Titan transgingival kitsNon rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6360H
Rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6360R
Non rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6361H
Rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6361R
Non rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6362H
Rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6362R
Retaining screwsRetaining screw for IDCAM® and IDALL® ≤ 25N.cm maximum (Screw head: Ø 2,5 mm)
0214
For prosthesis, short head ≤ 25N.cm maximum 0219
Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)
0211
Gold cylindersCylinder, gold, non rotational to cast on + screw - Morse taper connection 636
Screw-on abutments (FMP) with shoulderStraigth, 0°, incl. screw Transgingival height: 1,5mm 420011
Straigth, 0°, incl. screw Transgingival height: 3,0mm 420012
15° angled, incl. screw Transgingival height: 1,5mm 421511
15° angled, incl. screw Transgingival height: 3,0mm 421512
23° angled, incl. screw Transgingival height: 1,5mm 422311
23° angled, incl. screw Transgingival height: 3,0mm 422312
Kit D (FMP) with shoulder
420011 + 0211 + 0223 Kit D400
421511 + 0211 + 0223 Kit D415
422311 + 0211 + 0223 Kit D423
Zirconia TiBaseTitan abutment basis + screw conical, for lab 7636
Titan abutment basis + screw Platform switch (Ø3,6), for lab 7536
All the dimensions are in millimeters.
88 www.idisystem.eu
PROSTHETIC COMPONENTSREMOVABLE PROSTHESIS
IDUnit
IDUnit elements IDUnit attachment, Transgingival height: 1 mm U3601
IDUnit attachment, Transgingival height: 2,5 mm U3602
IDUnit attachment, Transgingival height: 4 mm U3604
IDUnit attachment, Transgingival height: 6 mm U3606
17° angled IDUnit attachment (1 mm high) U3621
30° angled IDUnit attachment (1 mm high) U3631
IDUnit analog IDUnit analog 333
IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S
Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334
Impression copying Impression copying, monobloc, to be screwed 321
IDUnit impression copying, Pick-up technique 322
Impression copying, plastic 335
Healing cap IDUnit healing cap 330
Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216
PRO
STHE
TIC
CO
MPO
NEN
TSID
CA
M®
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
MORSE TAPER CONNECTION
IDI IMPLANTS DIFFUSION INTERNATIONAL 89
IDLoc
IDLoc attachments Transgingival height: 1 mm L3601
Transgingival height: 2,5 mm L3602
Transgingival height: 4 mm L3604
Transgingival height: 6 mm L3606
Impression copying Impression copying, plastic 432
Analog IDLoc analog 433
Box Female part LOCFEM
Spherical attachments
Transgingival height: 1 mm 222361
Transgingival height: 2,5 mm 222362
Transgingival height: 4 mm 222364
Transgingival height: 6 mm 222366
Burnout spherical attachments
Burnout spherical attachment 9222
Paralleling guide for burnout spherical attachment 9223
Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122
O’ring retaining ring for O’ring attachment 0120
Nylon box for spherical attachment 0924
Connector barBurnout connector bar (by 3) 0931
Nylon clip 0025
Magnetic screws
Screw, REDEIM type 0024
Magnetic 0940
90 www.idisystem.eu
Focus on prosthetics THE IDUNIT
PROTOCOL FOR IDUNIT PLACEMENT
1 - REMOVE THE HEALING CAPS FROM THE IMPLANTS WITH THE ADAPTED SCREWDRIVER. INSERT THE APPROPRIATE IDUNIT ABUTMENT ONTO THE IMPLANT AND TIGHTEN IT TO 25 N.CM WITH THE SQUARE-TIPPED SCREWDRIVER (P/N 0014 OR P/N 0114). IT IS RECOMMENDED TO CARRY OUT A X-RAY CHECK ONCE THE ABUTMENT IS SCREWED.
2 - TAKE AN IMPRESSION WITH THE IMPRESSION COPYINGS:
CLOSED TRAY P/N 321
OPEN TRAY P/N 322
3 - POSITION THE PROSTHESIS IN THE PATIENT MOUTH AND SCREW IT WITH THE RETAINING SCREWS P/N 0216 AND TIGHTEN THEM TO 25N.CM WITH THE SCREWDRIVER P/N 0014 OR 0114.THE RETAINING SCREWS P/N 0216 AND TIGHTEN THEM TO 25N.CM WITH THE
CLOSED TRAY
P/N 321
OPEN TRAY
P/N 322
SCREWDRIVER P/N 0014 OR 0114.
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 91
PRO
STHE
TIC
APP
ROA
CH
STABILIZATION BAR WITH CLIPS FOR OVERDENTURE
EXAMPLE OF PROSTHETIC REHABILITATIONS
SCREW-ON CERAMIC FROM BURNOUT CYLINDER
SCREW-ON BRIDGE FROM BURNOUT CYLINDERS
GENERAL PROSTHETIC APPROACH
92 www.idisystem.eu
GENERAL PROSTHETIC APPROACH
BRIDGE ON MACHINED ABUTMENTS
STABILIZED OVERDENTURE WITH SCREWED TITAN SPHERICAL ATTACHMENTS AND O’RING BOXES
STABILIZED OVERDENTURE WITH IDLOC ATTACHMENTS
Non
con
tract
ual p
ictu
res
93
The RBS® sets Surgical set
for IDCAM/BIO
tapered implants
RBS® C drill
Surgical sets for cylindrical implants
RBS® drill
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
94 www.idisystem.eu
CONTENTS :16 drills
7 relating instruments
SURGICAL DRILL SET FOR THE IDCAM®/IDBIO®
P/N 415
P/N 0114
P/N 406
P/N 1114
P/N 409
P/N 0146
P/N 408
Hand piece screwdriver for prosthetics, length: 30mm
Contra angle screwdriver for prosthetics, length: 30mm
Hand piece screwdriver for screwing the implant, length: 30mm
Ratchet Instrument extension
Implant paralleling help Ø1,5mm
Depth tester
INCLUDES: P/N 415Ratchet
Short hex-tipped screwdriver P/N 0046
Screwdriver for relating instruments (short model) P/N 0014
HOLDERS IN DIFFERENT SIZESThe holders contain 4 RBS®C conical drills for cylindro-tapered implants.There are available in 8mm length; 10 mm length; 12 mm length; 15 mm length.
IDI IMPLANTS DIFFUSION INTERNATIONAL 95
The bone-recovering RBS® tapered drills were developed and tested in several hospitals. They ease the implant setting of the IDBIO® and IDCAM ranges.
*On each implant’s packaging there is a small colored sticker to match with the implant height. The code for each color is related to the one found on the RBS® conical drills for the IDCAM® and IDBIO® implants.
Length: 8mm Length: 10mm Length: 12mm Length: 15mm
Ø 2,0 mm
Ø 3,5 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 2,0 mm
Ø 3,5 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 2,0 mm
Ø 3,5 mm
Ø 4,2 mm
Ø 5,2 mm
Ø 2,0 mm
Ø 3,5 mm
Ø 4,2 mm
Ø 5,2 mm
820
083522
084227
085230
1020
103522
104223
105225
1220
123522
124223
125225
1520
153522
154223
155225
RBS®C DRILLS RANGE
DRILLING LENGTH
DRILLING LENGTHP/N P/N
Color code* Color code*
Drill headThe lower section incorporates a long cutting thread and tapers to a point at the drill head.
Color codeA colored ring on the depth stop indicates the maximum drill depth.
MarkingsMarkings on the shank indicate the diameter of the drill.
Depth stopThe depth stop limits how deep
the drill can be inserted, determining the maximum drilling depth.
Bone-harvesting channelA channel between the cutting thread and depth stop is used to collect bone
material for harvesting autogenous material for grafting.
8
8
8
8
10
10
10
10
12
12
12
12
15
15
15
15
Non
con
tract
ual p
ictu
res a
nd p
acki
ng
THE RBS®C TAPERED DRILLS TH
E RB
S®
SURG
ICA
L SET
S
96 www.idisystem.eu
The RBS® 2 set provides for implantologists and perio- implantologists who want to harvest bone during surgery for an autogenous graft.
This set containing 20 drills can be used for placing numerous implant types with an internal or external hexagon. Pilot drills with a diameter of 1,5mm are included for facilitating surgery.
NB : drills with a diameter of 1,5 and 2 mm do not have a bone-harvesting channel.
RBS® 2
815
1015
1215
1515
R 825
R 1025
R 1225
R 1525
820
1020
1220
1520
R 830
R 1030
R 1230
R 1530
R 835
R 1035
R 1235
R 1535
COLOR CODE NOTCHES P/N NOTCHES P/NNOTCHES P/N NOTCHES P/N NOTCHES P/N
1
1
1
1
3
3
3
3
2
2
2
2
4
4
4
4
5
5
5
5
RBS®
SURGICAL SETS
The RBS® 1 set provides safety for operators new to perio- implantology.The 12 drills in the set with a bone-harvesting channel are used to harvest autogenous graft material. They are used when placing cylindrical implants: 10mm, 12mm and 15mm of length with internal or external retention.
NB : Drills with a diameter of 1,5 and 2 mm do not have a bone-harvesting channel.
RBS® 1
1020
1220
1520
R 1030
R 1230
R 1530
R 1025
R 1225
R 1525
R 1035
R 1235
R 1535
COLOR CODE NOTCHES P/N NOTCHES P/NNOTCHES P/N NOTCHES P/N
2
2
2
4
4
4
3
3
3
5
5
5
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 97
Set contents
P/N 414 P/N 409 P/N 0046 P/N 1146
P/N 401
P/N 406
Profile drill
Ratchet + central part
Paralleling help of Ø mm implant
Contra-angle screwdriver hand piece for screwing the implant
Instrument extension
Hand piece screwdriver for screwing of the implant
P/N 403 ML P/N 0014 P/N 403
Square-tipped screwdriver, long, width 2 mm for closing and healing caps*
Square-tipped screwdriver, short, width 1.2 mm, for impression copings*
Square-tipped screwdriver, width 2mm for closing screw and healing cap
The RBS®3 set has the same feature as the RBS®2 set.This set contains 24 drills and additional instruments which are required to place implants up to 5 mm diameter.This set can be used for placing numerous implant types with an internal or external hexagon.
NB : drills with a diameter of 1.5 and 2 mm do not have a bone-harvesting channel.
RBS® 3
815
1015
1215
1515
R 825
R 1025
R 1225
R 1525
820
1020
1220
1520
R 830
R 1030
R 1230
R 1530
R 835
R 1035
R 1235
R 1535
R 840
R 1040
R 1240
R 1540
NOTCHES P/N NOTCHES P/NNOTCHES P/N NOTCHES P/N NOTCHES P/N NOTCHES P/N
1
1
1
1
3
3
3
3
2
2
2
2
4
4
4
4
5
5
5
5
6
6
6
6
* The RBS®1 set does not contain the elements ref 403ML and 0014.
THE
RBS®
SU
RGIC
AL S
ETS
COLOR CODE
www.idisystem.eu98
CYLINDRICAL RBS® DRILLSRBS® drills for harvesting bone were developed and tested in cooperation with dental hospitals. They are precisely tailored to user requirements and meet the highest standards of implantology and periodontal implantology.
Manufactured in accordance with the medical products directive, RBS® drills are made of hardened stainless steel. Their excellent cutting capacity ensures tissue heating is kept to an absolute minimum.NB: Drills with a diameter of 1,5 and 2 mm do not have a bone-harvesting channel.
Drilling procedure without bone harvesting
Drilling procedure with bone harvesting
Use the drills in an increasing sequence (in 0,5 mm stages) at a rotary speed of 250 rpm with ample cooling to avoid heating the bone.
- Use the drills in an increasing sequence (in 0.5 stages) at a rotary speed of 150 rpm without cooling.- When the bone-harvesting channel is full, place the drill in a
cup with physiological solution until the bone material loosens and settles on the bottom of the cup. Soak up the physiological solution and collect the bone material for the bone graft.
Depth stopLimits how deep the drill can be inserted, determining the maximum drilling depth.
Bone-harvesting channelA channel between the cutting thread and depth stop is used to collect bone material for harvesting autogenous material for grafting.
MarkingsMarkings on the
shank indicate the diameter of the drill:
Example for the IDI implants.
1 notch = Ø 1,5 mm2 notches = Ø 2,0 mm3 notches = Ø 2,5 mm4 notches = Ø 3,0 mm5 notches = Ø 3,5 mm6 notches = Ø 4,0 mm7 notches = Ø 4,5 mm8 notches = Ø 5,4 mm
Color codeA coloured ring on the depth stop indicates the maximum
drill depth (+/- 0,5 mm).
Example for the IDI implants:
Drill headThe lower section
incorporates a long cutting thread and tapers
to a point at the drill head.
Black = 6 mmYellow = 8mmRed = 10 mm
Green = 12mmBlue = 15mm
99
The OsteosinusThe Osteosinus 1 set
Osteosinus
Rectisinus
Angulosinus
Forsinus
Trepanosinus
Diskosinus
Technique by using the Trepanosinus
Technique by using the Forsinus
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
“The Osteosinus system of IDI firm - Implants Diffusion International - is an easy and reliable technique when we want to place an implant in a sinusal area. It permits to each dentist to perform a sinus floor elevation by crestal approach. Drills manufactured for the bone preparation are accute and lasting. The RBS® system for the bone harvesting is terrific”
Dr Rainer B. (Germany)
Consistent use of a depth stop over many years when harvesting bone surgically and the experience this provided enabled development of this technique. The technique has proved itself in a wide range of applications for more than fifteen years thanks to the rbs depth stop drills from Implants Diffusion International.
Osteotomes, trephines and drills included in the Osteosinus system have also benefited from this technology.
The Osteosinus concept facilitates sinus floor elevation and ensures that It is stress-free.
Clinical studies have indicated that an intact sinus membrane without tears is essential for successful grafting.
A sinus bone graft can either be harvested laterally (sinus lift) or crestally.
In many cases crestal sinus floor elevation completed with the Osteosinus is a practical alternative to a sinus lift.
Osteosinus, the most advanced technique in crestal sinus floor elevation
Indications for the Osteosinus it is mainly recommended for sinus floor elevation for placing one or two implants.
100 www.idisystem.eu
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 101
THE OSTEOSINUS 1 SET
RL 33
RL 43
RL 53
RL 63
RL 73
RL 83
AL 33
AL 43
AL 53
AL 63
AL 73
AL 83
TL 33
TL 43
TL 53
TL 63
TL 73
TL 83
FL 33
FL 43
FL 53
FL 63
FL 73
FL 83
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
Ø 3 mm
LENGTH in mm
LENGTH in mm
LENGTH in mm
LENGTH in mm
P/N
P/N
P/N
P/N
DIAMETER
DIAMETER
DIAMETER
DIAMETER
3
3
3
3
4
4
4
4
5
5
5
5
7
7
7
7
6
6
6
6
8
8
8
8
Osteosinus (osteotome holder)
Diskosinus diameter 3 mm (bladed wheels for enlarging the bone base)
Osteosinus monobloc
Surgical stand
Base plate
P/N OST 1
P/N D3
P/N OSTM
P/N PLS
P/N BIC 1
6 Rectisinus (straight osteotome with colour-coded depth stop)
6 Angulosinus (angled osteotome with colour-coded depth stop)
6 Trepanosinus (trephine drill with colour-coded depth stop)
6 Forsinus (drill with colour-coded depth stop)
Important: The instruments with a 3 mm diameter are used for standard implants (3,5 to 4,4 mm Ø).
OST
EOSI
NUS
www.idisystem.eu
OSTEOSINUSThe Osteosinus is used for attaching a straight or angled osteotome depending on the operating site.
After assembling the osteotome, use the slide mallet to compact the bone.
Removable slide mallet
Can be dismantled
Shock absorber
Locking ring for the osteotome
102
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 103
RECTISINUS
ANGULOSINUS
This set contains six straight osteotomes with a colour-coded depth stop, Ø 3 mm, length 3 mm, 4 mm, 5 mm, 6 mm, 7 mm, 8 mm.
Insert the Rectisinus into the osteotome, position the guide in the operating site and compact the bone using the slide mallet.
This set contains six angled osteotomes with a colour-coded depth stop, Ø 3 mm, length 3-4-5-6-7 and 8 mm.
Insert the angulosinus into the osteotome, position the guide in the operating site and compact the bone using the slide mallet.
Depth stop limits the insertion depth of the osteotome
Depth stop limits the insertion depth of the osteotome
Colour coding for the depth
stop length
Colour coding for the depth
stop length
Colour coding for the
diameter
Colour coding for the
diameter
Guide for positioning the
osteotome
Guide for positioning the
osteotome
LENGTH
LENGTH
COLOR
COLOR
3
3
4
4
5
5
6
6
7
7
8
8
Lengths and colour-coded table for a 3 mm Ø
Lengths and colour-coded table for a 3 mm Ø
OST
EOSI
NUS
www.idisystem.eu
FORSINUS
TREPANOSINUS
This set contains six drills with a bone-harvesting channel and colour-coded depth stop, Ø 3 mm, length 3mm, 4 mm, 5mm, 6mm, 7mm, 8mm.
Use the drill at 70rpm without water cooling.
This set contains six trephines with a colour-coded depth stop, Ø 3 mm, length 3 mm, 4 mm, 5 mm, 6 mm, 7 mm and 8 mm.
Use the trephine at 70 rpm without water cooling.
Depth stop limits the insertion depth of the osteotome
Colour coding for the depth
stop length
Colour coding for the
diameter
Bone-harvesting
channel3
3
4
4
5
5
6
6
7
7
8
8
Lengths and colour-coded table for a 3 mm Ø
Lengths and colour-coded table for a 3 mm Ø
Depth stop limits the insertion depth of the osteotome
Colour coding for the depth stop length
Colour coding for the diameter
Window for extracting the bone cylinder
104
LENGTH
COLOR
LENGTH
COLOR
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 105
OST
EOSI
NUS
DISKOSINUSThis set contains a small bladed wheel, Ø 3 mm (red ring)
The wheel is used after the Forsinus drill with the same diameter. Using a circular movement the bladed wheel enlarges the bone base below the sinus and provides it which increased resilience when using the osteotome.
Colour coding for the
diameter
Locking ring for the osteotome
1 2
5
3
6
4
www.idisystem.eu
TECHNIQUE BY USING THE TREPANOSINUS
Select a suitable section on the X-ray of the implant site and measure the bone availability (here: 8 mm).
Fill the cavity with the filler material.
Remove the trephine.
Place the implant after compacting approx. 2 cubic centimeters of the filler material.
Use a 7 mm long trephine Trepanosinus (red ring on top) with a bone availability of 8 mm.
Continue compacting the bone. The filler material gradually elevates the sinus membrane.
Depending on the composition of the operating site, select a straight or angled 8 mm long Osteosinus (yellow ring on top), attach it and use it to compact the bone cylinder. Sometimes because of a very resistant bone, it is necessary to start compacting with a surgical hammer.
Allow a healing period of approx. 8 months during which osseointegration is completed.
1
5
2
6
3
7
4
8
NB: we recommend checking osseointegration with a scanner before loading the implant.
8mm
106
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 107
TECHNIQUE BY USING THE FORSINUS
Select a suitable section on the X-ray of the implant site and measure the bone availability (here: 7 mm)
Attach a 7 mm long osteotome (red ring on top) to the Osteosinus and use the instruments to compact the bone. Sometimes in front of a very resistant bone, it is necessary to start compacting with a surgical hammer.
Use the diskosinus
bladed wheel, rotating it slowly with a circular movement, to enlarge the bone base below the sinus and provide it which increased resilience.
Then place the implant.
Use the 6 mm long forsinus drill (red ring on top) with a bone availability of 7 mm.
Repeat the procedure until 1,5 to 2 cubic centimeters of filler material has been inserted. This gently elevates the sinus membrane without tearing it.
Fill the cavity with filler material.
Allow a healing period of approx 8 months during which osseointegration is completed.
1
5
2
6
3
7
4
8
NB: we recommend checking osseointegration with a scanner before loading the implant.
7mm
OST
ÉOSI
NUS
ACCESSORIES & INSTRUMENTS
www.idisystem.eu
Ridge spreading condensing
Trephines
- 4 ridge spreaders with gradual diameters : 1,5 – 2 – 2,5 and 3 mm (on the lower edge) 2 – 2.3 – 3.4 and 3.9 mm (under the depth stop)
- Length: 20 mm, round edge- Colour coding for safety purpose - To set all types of implants to 4 mm diameter- Avoid the use of sharp drills on very narrow sites (the periodontal ligament is respected)- For lateral or vertical condensation- Gradual insertion (maximum 5 rpm) always with a 1/64 contra-angle.
Very sharp trephines in surgical stainless steel for bone explantation.Equipped with depth stops and lateral windows for an easy clearing of the recovered bone.
1,5 mm (white)P/N EX15
3,0 mm (green)P/N EX30
2,0 mm (yellow)P/N EX20
2,5 mm (red)P/N EX23
TL 33TL 43TL 53TL 63TL 73TL 83
TL 34TL 44TL 54TL 64TL 74TL 84
Ø 3 mmØ 3 mmØ 3 mmØ 3 mmØ 3 mmØ 3 mm
Ø 4 mmØ 4 mmØ 4 mmØ 4 mmØ 4 mmØ 4 mm
LENGTH in mm
P/NDIAMETER
3
3
4
4
5
5
7
7
6
6
8
8
Depth stop to limit the depth of drilling
Colour coding for the depth stop length
Colour coding for the diameter
Window for extracting the bone cylinder
108
FOR MORSE TAPER AND HEXAGONAL CONNECTION
AC
CE
SS
OR
IES
&
INS
TR
UM
EN
TS
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
trac
tual
pic
ture
s
IDI IMPLANTS DIFFUSION INTERNATIONAL 109
Ratchets
Thread taps
Screwdrivers
Instruments
Bone thread tap (Ø 4 mm) P/N TAR 4
RatchetP/N 415
Ratchet + central part P/N 414
central partP/N 416
Bone thread tap (Ø 5 mm) P/N TAR 5
Bone thread tap(Ø 6 mm) P/N TAR 6
Manual thread tap, hardened stainless steel
P/N TAR M2
Manual screwdriver to screw the implant
P/N 0846
Hex-tipped screwdriver, short
P/N 0046
Hex-tipped screwdriver, long
P/N 0146
Screwdriver for relating instruments (long model)
P/N 0114
Screwdriver for relating instruments (short model)
P/N 0014
Instruments with dental shank, square-tipped instrument (short)
P/N 1014
Instruments with dental shank, square-tipped instrument (long)
Instruments with dental shank, hex-tipped instrument (short)
P/N 1114 P/N 1046
Instruments with dental shank, hex-tipped instrument (long)
P/N 1146 P/N 406
Instrument extension
P/N 403 ML P/N 403 M
Square-tipped screwdriver, long, width 1,4mm, for closing cap and healing caps*
Square-tipped screwdriver, short, width 1,4mm, for closing cap and healing caps* P/N 405 ML P/N 405 M
Square-tipped screwdriver, long, width 0,85mm, for impression copyings**
Square-tipped screwdriver, short, width 0,85mm, for impression copyings**
*Screwdriver for contra-angle P/N 403. ** Screwdriver for contra-angle P/N 405.
P/N 0148
Abutment remover for tapered implants (IDCAM® and IDALL® product lines)
www.idisystem.eu
PACKAGING FOR IMPLANTS IDI
A DOUBLE STERILE PACKAGING
Method 1: Pick up the implant with a contra-angle
Method 2: Pick up the implant
manually
PressPress
RemoveRemove
1
11
22
2
3 4
110
FOR MORSE TAPER AND HEXAGONAL CONNECTION
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
IMPLANTS DIFFUSION INTERNATIONAL
Non
con
tract
ual p
ictu
res
IDI IMPLANTS DIFFUSION INTERNATIONAL 111
PAC
KAG
ING
FO
R ID
I IM
PLA
NTS
Pick up the closing cap from the packaging
Pick up the healing cap from the lower part of the packaging
Take the packaging Insert the screwdriver
Rotate by 90° Remove
1
3
2
4
Take the packaging Insert the screwdriver
Rotate by 90° Remove
1
3
2
4
Cleaning and sterilisation instructions1. Clean the
instruments during 15 minutes in a decontamination bath with ultrasound
2. Rinse thoroughly3. Dry perfectly4. Sterilize for 90
minutes in a dry heat at 150° C or autoclave at 135° C for 20 minutes
23/25 rue Émile Zola - 93100 Montreuil - FranceTél. : +33 (0)1 48 70 70 48 – Fax : +33 (0)1 48 70 44 58www.idisystem.eu
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
SinceÊ1987
IMPLANTS DIFFUSION INTERNATIONAL
Photo credits: Agence G
reen and White &
IDI. Products featured in our catalogue are intended for healthcare professionals - February 2015 issue.
Print in the France. Any reproduction for all countries is strictly prohibited w
ithout the prior written perm
ission of the IDI com
pany. Non contractual photos and illustrations.