In-Line Cell Manager Configuration and Loading

Date: Octobre2014

Page 2: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

2

Cell Manager Configuration Module

• CoreView In Line Software consists of two main Modules• Measurement Unit (CoreView Teach for In-Line)• Cell Manager

• On each computer which is connected to the WLS400A system, the Measurement Unit is installed

• The Cell manager is installed on one of the units computer.

• In-Line configuration of both Units and the Cell Manager is done through a configuration module: C:\Cognitens\bin64\Inline.Configuration.UI.exe which is executed in the Cell Manager Unit.

Page 3: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

3

Configuration Interface

Computer Name

Cell NameHas to be the same in all Cell Units

Unit Name

Press for Cell Manager Configuration

Important:Don’t forget to press Apply after you finish with all the configuration.

Page 4: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

4

Cell Manager Configuration

Path to result file generated in XML format. (For Back compatibility)

Page 5: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

5

Cell Manager Configuration

GateWay Computer IP Address

Page 6: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

6

Cell Manager Configuration

Currently only Diagnostic report is supported

Page 7: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

7

Cell Manager Configuration

No Change Required

Page 8: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

8

Configuration Interface

Press to configure Units

Important:Don’t forget to press Apply after you finish with all the configuration.

Page 9: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

9

Unit Configuration

Full Path to local CTP. Including computer nameMultiple CTP supported

Page 10: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

10

Unit Configuration

DataServer Computer name. IP address is also supported

Page 11: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

11

Unit Configuration

No Change Required

Page 12: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

12

Unit Configuration

Full path to Bundle Folder. Has to be the same on both units

Page 13: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

13

Load In-Line Measurement System

• To Load the In-Line Measurement System run: C:\Cognitens\bin64\Inline.Cell.UI.exe

• The In-Line Cell UI enables:• Loading\Unloading all the Measurement In-Line process• Review the existing bundles and set the Delete option for

the output data (this includes all the images and point cloud)

• Once the Loading off all the processes is done the system is ready to execute In-Line measurement process

Page 14: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

14

Load In-Line Measurement System – Bundle Configuration

Red Bundles are marked Not to delete automatically

This will delete the outputs on both computers after the results are generated

Use this to delete existing outputs which were not deleted automatically

Page 15: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

15

Load In-Line Measurement System

Press to start the process

Page 16: In-Line Cell Manager Configuration and Loading Date: Octobre2014.

16

Load In-Line Measurement System

Press to Stop the process

All Process have to be Green and ReadyAnd Cell Manager Connected to GateWay