Index
Nexans AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listedis approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application.
© 2014, AmerCable Incorporated
36-311 Type W (Flat) 2/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
36-314 Type W (Flat) 4/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
36-320 Type G (Flat) 2/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
36-322 Type G-GC (Flat) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
36-431 Type W (Round) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
36-432 Type W (Round) 4/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13
36-442 Type G-GC (Round) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . . . 14-15
36-503 Type SHD-GC (Round) 3/C 2kV . . . . . . . . . . . . . . . . . . . . . . 16-17
36-504 Type SHD-PCG 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19
36-505 Type SHD-CGC 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
36-506 Type SHD-CGC 5kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
36-510 Type SHD (Flat) 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25
36-515 Type SHD-GC 5kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27
Type SHD-GC (Round) 3/C 2300V . . . . . . . . . . . . . . . . . . . . . . 27
36-516 Type SHD-PCG 5kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29
36-601/602/604 Type MP-GC 3/C 5-15kV (EP/CPE) . . . . . . . . . . . . . . . . . . . . 30-31
36-621/622/624 Type MP-GC 3/C 5-15kV (XLP/PVC) . . . . . . . . . . . . . . . . . . . 32-33
36-202-018 Longwall Signal Cable 2-9/C 50 Volts . . . . . . . . . . . . . . . . . . . 34
36-202-118 Underground Lighting Cable 2-9/C 110 Volts . . . . . . . . . . . . . . 35
37-119 DLO 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-37
36-501 VFD 2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-39
Tiger Stripes – Reflective and Standard . . . . . . . . . . . . . . . 40-41
Jacket Materials – CPE and TPU . . . . . . . . . . . . . . . . . . . . . . . 42
Safety, Training and Education . . . . . . . . . . . . . . . . . . . . . . . . 43
Cable Assemblies and Refurbishing . . . . . . . . . . . . . . . . . . 44-45
El Dorado, Arkansas
Made in America
1
Committed to Safer,More Productive MiningSince the electrification of mines,Nexans AmerCable’s core business has been powering mine equipment.Surface or underground – Nexans AmerCable has acable productivity solution for you. Our innovatively engineered and manufactured Tiger® Brand cable lineis designed for your toughest conditions. As the leading producer of mining cables in North America,Nexans AmerCable is dedicated to producing:
n cables that last longer in harsh mining environments
n cables designed to help provide greater levels of safety and productivity
n lowest cable cost per ton!
Mining Cable Innovationn Designing insulating and jacketing materials that
are more flexible with greater resistance to abrasion and moisture
n Cable constructions that last longer providing reduced down time for increased production
n New product development that addresses environmental, safety and cost reduction issues specific to your mining application
Operating Excellencen Industry leading On-Time
delivery
n Standard lead-time of 8 to 10 weeks
n Urgent response shipment capability of 2 to 4 weeks
n Strategically located inventories throughout the major mining regions
n Nexans AmerCable is an ISO-9001 certified manufacturer
Hands-on Field SupportOur mine-experienced field application engineers are available 24/7 for on-site evaluation and solutions. Theyalso conduct education and training sessions that addresssafety, splicing and cable handling issues. See page 43 for more information.
Factory InstalledCable Assemblies
See pages 44-45 for more information.
SAVETIME &MONEY
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96132
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-311
Type W Flat 2/CMold-cured Jacket • 600/2000 Volts
ApplicationFor use on D.C. off-track mining equipment.Especially designed for D.C. shuttle cars, drills,cutting and loading machines. Recommendedmaximum continuous conductor temperature is 90°C.
Cable carries “P-07-KA - - MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
JacketMold-cured thermosetwith cable identification via permanent marking.Standard Jacket: Black
ConductorsFlexible tinned copper
ReinforcementSynthetic yarn over assembly
D-shaped cross-section
� Mine Safety & Health Administration 07-KA - - MSHA.
� Pennsylvania Department of Environmental Protection P-07-KA.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 3
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" Minor Dimension± 0.040" Major Dimension
SizeAWG
8 6 4 2 1 1/0 2/0 4/0
36-311-
008 006 004 002 001 010 020 040
No. of Wiresper
Conductor
133 7x19 133 7x19 259 7x37 259 7x37 259 7x37 259 7x37 329 7x47 532 19x28
InsulationThickness
mils
6060606080808080
NominalOutside
Dimensions in.
0.51 x 0.840.56 x 0.930.61 x 1.050.73 x 1.240.81 x 1.400.93 x 1.510.99 x 1.631.10 x 1.89
Approx.Weightlbs. per1,000 ft.
340 440 580 850 1070 1310 1600 2300
Ampacity*40°C
Ambient Temp
72 95 127 167 191 217 250 328
Power Conductors
36-311 • Type W Flat 2/C • 600/2000 Volts
ShuttleCar
Primary UsageRecommendation
Number of Multiplying Layers Correction Factors
1 0.85 2 0.65 3 0.45 4 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.1
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.90
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
1Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96134
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-314
Type W Flat 4/CMold-cured Jacket • 600/2000 Volts
ApplicationFor use on A.C. off-track mining equipment.Especially designed for A.C. shuttle cars, drills,cutting and loading machines. Recommendedmaximum continuous conductor temperature is 90°C.
Cable carries “P-07-KA - - MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-33 and B-172.
Insulation90°C ethylene-propylenerubber (EPR). Color codedblack, white, red, green.
JacketMold-cured thermosetwith cable identification via permanent marking.Standard Jacket: Black
ConductorsFlexible tinned copper
Square and D-shaped cross-section
� Mine Safety & Health Administration 07-KA - - MSHA.
� Pennsylvania Department of Environmental Protection P-07-KA.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
ReinforcementSynthetic yarn over assembly
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 5
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.050" Minor Dimension± 0.080" Major Dimension
SizeAWG
6 4 2 1
36-314-
006 004 002 001
No. of Wiresper
Conductor
133 7x19 259 7x37 259 7x37 259 7x37
InsulationThickness
mils
60606060
NominalOutside
Dimensions in.
0.68 x 1.710.76 x 1.910.82 x 2.250.98 x 2.54
Approx.Weightlbs. per1,000 ft.
910 1220 1720 2240
Ampacity*40°C
AmbientTemp
72 93 122 143
Power Conductors
36-314 • Type W Flat 4/C • 600/2000 Volts
Pump
ShuttleCar
RoofBolter
Primary UsageRecommendation
Number of Multiplying Layers Correction Factors
1 0.85 2 0.65 3 0.45 4 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.1
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.90
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
1Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96136
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-320
Type G Flat 2/CMold-cured Jacket • 2000 Volts
ApplicationFor use on D.C. off-track mining equipment.Especially designed for D.C. shuttle cars, drills,cutting and loading machines. Recommendedmaximum continuous conductor temperature is 90°C.
Cable carries “P-07-K - - MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.Insulation
90°C ethylene-propylenerubber (EPR)
JacketMold-cured thermosetwith cable identification via permanent marking.
ConductorsFlexible tinned copper
ReinforcementSynthetic yarn over assembly
Ground WireUni-directional lay flexible tinned copper
D-shaped cross-section
� Mine Safety & Health Administration 07-KA - - MSHA. All underground miningcables
� Pennsylvania Department of Environmental Protection P-07-KA. All underground mining cables.
� Insulated Cable Engineers Association S-75-381. Design standard for mining cables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 7
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" Minor Dimension± 0.040" Major Dimension
SizeAWG
6 4 2 1 1/0 2/0
SizeAWG
8 7 5 4 3 2
36-320-
006 004 002 001 010 020
No. of Wiresper
Conductor
133 7x19 259 7x37 259 7x37 259 7x37 259 7x37 329 7x47
No. of Wiresper
Conductor
270 6x45 180 6x30 168 6x28 168 6x28 204 6x34 246 6x41
InsulationThickness
mils
606060808080
NominalOutside
Dimensions in.
0.56 x 1.020.61 x 1.150.73 x 1.350.81 x 1.550.93 x 1.670.99 x 1.85
Approx.Weightlbs. per1,000 ft.
500 660 990 1230 1540 1870
Ampacity*40°C
Ambient Temp
95 127 167 191 217 250
Power Conductors Grounding Conductor
36-320 • Type G Flat 2/C • 2000 Volts
Primary UsageRecommendation
ShuttleCar
RoofBolter
Number of Multiplying Layers Correction Factors
1 0.85 2 0.65 3 0.45 4 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.1
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.90
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
1Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-96138
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-322
Type G-GC Flat 3/CMold-cured Jacket • 2000 Volts
ApplicationFor use on A.C. off-track mining equipment.Especially designed for A.C. shuttle cars, drills,cutting and loading machines. Recommendedmaximum continuous conductor temperature is 90°C.
Cable carries “P-07-KA-MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
JacketMold-cured thermosetwith cable identification via permanent marking.
ConductorsFlexible tinned copper
ReinforcementSynthetic yarn over assembly
Ground WireUni-directional lay flexible tinned copperwith green covering
Ground Check WireUni-directional lay flexible tinned copperwith yellow insulation
Square and D-shaped cross-section
� Mine Safety & Health Administration 07-KA - - MSHA
� Pennsylvania Department of Environmental Protection P-07-KA.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 9
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.050" Minor Dimension± 0.080" Major Dimension
Ground Check– #8 AWG minimum
SizeAWG
6 4 2 1
SizeAWG
8 7 5 4
36-322-
006 004 002 001
No. of Wiresper
Conductor
133 7x19 259 7x37 259 7x37 259 7x37
No. of Wiresper
Conductor
270 6x45 180 6x30 168 6x28 168 6x28
InsulationThickness
mils
60606080
NominalOutside
Dimensions in.
0.67 x 1.690.75 x 1.890.81 x 2.230.97 x 2.48
Approx.Weightlbs. per1,000 ft.
940 1240 1690 2170
Ampacity*40°C
AmbientTemp
79 104 138 161
Power Conductors Grounding Conductor
36-322 • Type G-GC Flat 3/C • 2000 Volts
Primary UsageRecommendation
Pump
ShuttleCar
RoofBolter
Number of Multiplying Layers Correction Factors
1 0.85 2 0.65 3 0.45 4 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.1
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.90
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
1Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961310
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-431
Type W Round 3/CMold-cured Jacket • 2000 Volts
ApplicationEspecially suitable for general use where baregrounding conductors are not required ordesired. Recommended maximum continuousconductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
Round-shaped cross-section
TapeNon-conducting
Photo courtesy Joy Mining Equipment
See Page 42 for jacket color options.
See Page 40-41 for Tiger Stripe options
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 11
36-431 • Type W Round 3/C • 2000 Volts
1Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jackets available upon request.
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" 8-1 AWG± 0.040" 1/0 - 2/0 AWG± 0.050" 3/0 - 4/0 AWG
SizeAWG
8 6 4 2 1 1/0 2/0 3/0 4/0
36-431-
008 006 004 002 001 010 020 030 040
No. of Wiresper
Conductor
133133259259 259266 323418 532
InsulationThickness
mils
606060608080808080
NominalOutside
Dimensions in.
0.91 1.01 1.17 1.34 1.51 1.65 1.75 1.89 2.04
Approx.Weightlbs. per1,000 ft.
550 730 1020 1430 1800 2140 2580 2922 3800
Ampacity*40°C
Ambient Temp
59 79 104 138 161 186 215 249 287
Power Conductors
Number of Multiplying Layers Correction Factors
1 0.85 2 0.65 3 0.45 4 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.1
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.90
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
1Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961312
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-432
Type W Round 4/CMold-cured Jacket • 2000 Volts
ApplicationEspecially suitable for use with mobile miningequipment such as continuous miners, drills,cutters, loading machines and AC shuttle cars.Type W is for applications where bare grounding conductors are not required or desired.Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
Round-shaped cross-section
See Page 42 for jacket color options.
See Page 40-41 for Tiger Stripe options
TapeNon-conducting
PureIntegral Fillfor greatertorsion
resistance
PureIntegral Fill
Cable shown with optional Tiger Stripes. See page 40-41.Photo courtesy Joy Mining Equipment
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 13
36-432 • Type W Round 4/C • 2000 Volts
Primary UsageRecommendation
1Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jackets available upon request.
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" 8-1 AWG± 0.040" 1/0 - 2/0 AWG± 0.050" 3/0 - 4/0 AWG
SizeAWG
8 6 4 2 1 1/0 2/0 3/0 4/0
36-432-
008 006 004 002 001 010 020 030 040
No. of Wiresper
Conductor
133133259259 259266 323418 532
InsulationThickness
mils
606060608080808080
NominalOutside
Dimensions in.
0.99 1.10 1.27 1.48 1.68 1.79 1.93 2.07 2.26
Approx.Weightlbs. per1,000 ft.
670 890 1250 1800 2270 2680 3200 3627 4650
Ampacity*40°C
Ambient Temp
54 72 93 122 143 165 192 221 255
Power Conductors
ContinuousMiner
ShuttleCar
Pump
Number of Multiplying Layers Correction Factors
1 0.85 2 0.65 3 0.45 4 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.1
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.90
1Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961314
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-442
Type G-GC Round 3/CMold-cured Jacket • 2000 Volts
ApplicationEspecially suitable for use with mobile miningequipment such as continuous miners, drills,cutters, loading machines, AC shuttle cars andpumps. Type G-GC is for applications wheregrounding conductors and a ground check conductor are required. Recommended maximum continuous conductor temperature is 90°C. Suitable for shallow water submersion.
Cable carries “P-7K-184-MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanentmarking.
ConductorsFlexible tinned copper
Ground WiresFlexible tinned copper
Ground Check Conductor2
Flexible tinned copper with yellow polypropyleneinsulation
Round-shaped cross-section
Photo courtesy Joy Mining Equipment
PureIntegral Fillfor greatertorsion
resistance
PureIntegral Fill
TapeNon-conducting
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
PumpApplicationConstruction36-442 is available withinsulated grounds forpump applications thatrequire this specification.
� Mine Safety & Health Administration 184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 15
1Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jackets available upon request.2Ground Check Conductor – 10 AWG (minimum 49 strand 7x7) ground check conductor on
8 AWG through 2 AWG cable.
8 AWG (minimum 133 strand 7x19) ground check conductor on 1 AWG through 4/0 AWG cable.
6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 0.030" 8-1 AWG± 0.040" 1/0 - 2/0 AWG± 0.050" 3/0 - 4/0 AWG± 0.060" 250 - 500 kcmil
36-442 • Type G-GC Round 3/C • 2000 Volts
Primary UsageRecommendation
ContinuousMiner
ShuttleCar
RoofBolter
Pump
SizeAWG
8 6 4 2 1 1/0 2/0 3/0 4/0250350500
SizeAWG
10 10 8 7 6 5 4 2 2 2 1/0 2/0
No. of Wiresper
Conductor
133259259259259266323418 532627888
1221
No. of Wiresper
Conductor
4949
133133133133259259 259259266323
InsulationThickness
mils
606060608080808080959595
NominalOutside
Dimensions in.
0.97 1.05 1.19 1.34 1.51 1.65 1.75 1.89 2.04 2.39 2.68 3.03
Approx.Weightlbs. per1,000 ft.
600 750 1070 1480 1890 2340 2750 3377 3980 5000 6750 8900
Ampacity*40°C
Ambient Temp
59 79 104 138 161 186 215 249 287 320 394 487
Power Conductors Grounding Conductors
36-442-
008 006 004 002 001 010 020 030 040 250 350 500
Number of Multiplying Layers Correction Factors
1 0.85 2 0.65 3 0.45 4 0.35
Reel Correction FactorsFor use with ampacities when oneor more layers of cable are woundon a reel. Cables must be deratedto prevent over heating on reel.1
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.901Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
See Page 13 for AWG/Metric Cross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961316
36-503
Type SHD-GCMold-cured Jacket • 2000 Volts
ApplicationHeavy duty portable power cable for use in circuits not exceeding 2,000 volts. Designed for applications such as longwall shearers, continuous miners, loaders, drills, conveyors,pumps and mobile equipment where groundingconductors, a ground check conductor andmetallic shielding are required. Recommended maximum continuous conductor temperature is90°C. Suitable for shallow water submersion.
Cable carries “P-7K-184-MSHA” marking indicating acceptance as flame resistant by thePennsylvania Department of EnvironmentalProtection and the Mine Safety and HealthAdministration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
TapeNon-conducting
Insulation90°C ethylene-propylenerubber (EPR)
Ground WiresFlexible tinned copper
Ground Check Conductor2
Flexible tinned copperwith yellow polypropyleneinsulation
Round-shaped cross-section
InsulationShieldingTinned copperand color codednylon braid
Separator Tape
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
PureIntegral Fillfor greatertorsion
resistance
PureIntegral Fill
Photo courtesy Joy Mining Equipment
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-7K-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
� Canadian Standards Association Type SHD-GC FT4
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 17
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-503 • Type SHD-GC 3/C • 2000 Volts
Primary UsageRecommendation
ContinuousMiner
Longwall Miner
Pump
*Ampacity – Based on continuous duty at 90°C conductor temperature.
1Jacket – Extra-Heavy-Duty (EHD) CPE jacket. Black is standard. Colored EHD CPE jackets available upon request. See page 42.
2Ground Check Conductor – 10 AWG (minimum 49 strand 7x7) ground check conductor on 8 AWG through 2 AWG cable.
8 AWG (minimum 133 strand 7x19) ground check conductor on 1 AWG through 4/0 AWG cable.
6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.
Tolerances – ± 5% of nominal outside diameter
SizeAWG
6 4 2 1 1/0 2/0 3/0 4/0250350500
SizeAWG
10 8 6 5 4 3 2 1 1/0 2/0 4/0
No. of Wiresper
Conductor
133259259259266323418 532627888
1221
No. of Wiresper
Conductor
49133133133259259259 259266323532
InsulationThickness
mils
7070708080808080959595
NominalOutside
Dimensions in.
1.29 1.40 1.59 1.76 1.86 2.00 2.13 2.31 2.51 2.81 3.19
Jacket Thickness
mils
155 155 170 190 190 205 205 220 220 235 265
Approx.Weightlbs. per1,000 ft.
1160 1490 2000 2450 2840 3400 3680 4860 5950 740010100
Ampacity*40°C
Ambient Temp
93 122 159 184 211 243 279 321 355 435 536
Power Conductors Grounding Conductors
36-503-
006 004 002 001 010 020 030 040 250 350 500
RoofBolter
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.901Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961318
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-504
Type SHD-PCG • LongwallMold-cured Jacket • 2000 Volts
ApplicationHeavy duty portable power cable designed foruse on longwall shearers, where three shieldedpower conductors, three unshielded controlconductors, and a grounding conductor arerequired. Recommended maximum continuousconductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating acceptance as flame resistant by thePennsylvania Department of EnvironmentalProtection and the Mine Safety and HealthAdministration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Ground ConductorFlexible tinned copper located in the center of the cable
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
TapeNon-conducting
Insulation90°C ethylene-propylenerubber (EPR)Control Group 3 Conductors
Flexible tinned copperethylene polypropylene rubberinsulation color coded black,white, red and an overall thermosetting jacket
Round-shaped cross-section
Insulation ShieldingTinned copper and color-coded nylon braid
Separator TapeNon-conducting
See Page 42 for jacketcolor options.
PureIntegral Fillfor greatertorsion
resistance
PureIntegral Fill
Photo courtesy DBT America
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381.
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 19
36-504 • Type SHD-PCG Longwall • 2000 Volts
Primary UsageRecommendation
Longwall Miner
*Ampacity – Based on continuous duty at 90°C conductor temperature.
1Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
Tolerances – ± 5% of nominal outside diameter
SizeAWG
2/0 3/0 4/0
SizeAWG
2 1 1/0
SizeAWG
8 8 6
No. of Wiresper
Conductor
323418532
No. of Wiresper
Conductor
246258426
No. of Wiresper
Conductor
133133133
NominalOutside
Dimensions in.
2.23 2.32 2.67
Approx.Weightlbs. per1,000 ft.
3510 4075 4990
Ampacity*40°C
Ambient Temp
243 279 321
Power Conductors Grounding Conductors Control Conductors
36-504-
020 030 040
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.901Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961320
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-505
Type SHD-CGC 3/CMold-cured Jacket • 2000 Volts
ApplicationHeavy duty portable power cable for use in circuitsnot exceeding 2,000 volts. Designed for applicationssuch as longwall shearers, continuous miners, loaders, drills, conveyors, pumps, and other mobileequipment requiring grounding conductors, where a ground check conductor, and metallic shieldingare required. Recommended maximum continuousconductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating acceptance as flame resistant by thePennsylvania Department of Environmental Protectionand the Mine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceeds ICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosettingChlorinated Polyethylene(CPE) Jacket. Cableidentification via permanent marking.
ConductorsFlexible tinned copper
Insulation ShieldingTinned copper and color-coded nylon braid
Ground Check Conductor2
Flexible tinned copper withyellow insulation located inthe center of the cable
Round shaped cross-section
Ground WiresFlexible tinned copper
TapeNon-conductingSeparator TapeNon-conducting
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
PureIntegral Fillfor greatertorsion
resistance
PureIntegral Fill
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & ApprovalsPhoto courtesy Eickhoff
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 21
1Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
2Ground Check Conductor – 16 AWG tinned copperconductor, designed to withstand extreme flexingand be extensible, insulated with yellow polypropylene
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – ± 5% of nominal outside diameter
36-505 • Type SHD-CGC 3/C • 2000 Volts
Primary UsageRecommendation
Longwall Miner
ContinuousMiner
SizeAWG
2/0 3/0 4/0350
SizeAWG
5 4 3 1
No. of Wiresper
Conductor
323418 532888
No. of Wiresper
Conductor
133259259259
InsulationThickness
mils
80808095
NominalOutside
Dimensions in.
2.09 2.21 2.36 2.81
Jacket Thickness
mils
205 205 220 250
Approx.Weightlbs. per1,000 ft.
3400 3934 4860 7400
Ampacity*40°C
Ambient Temp
243 279 321 435
Power Conductors Grounding Conductors
36-505-
020 030 040 350
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.901Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961322
36-506
Type SHD-CGC 3/CMold-cured Jacket • 5000 Volts
Insulation90°C ethylene-propylenerubber (EPR)
Jacket1
Reinforced mold-cured thermosettingChlorinated Polyethylene(CPE) Jacket. Cableidentification via permanent marking.
ConductorsFlexible tinned copper
Insulation ShieldingTinned copper and color-coded nylon braid
Ground Check Conductor2
Flexible tinned copper withyellow insulation located inthe center of the cable
Ground WiresFlexible tinned copper
Strand ShieldSemi-conductinglayer
ApplicationHeavy duty high voltage portable power cablefor use in circuits not exceeding 5000 volts.Designed for applications such as longwall miners, continuous miners, conveyors, pumps,and other mobile equipment requiring groundingconductors, a ground check conductor, andmetallic shielding overall. Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating acceptance as flame resistant by thePennsylvania Department of EnvironmentalProtection and the Mine Safety and HealthAdministration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.
Round-shaped cross-section
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
Photo courtesy Joy Mining Equipment
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-7K-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 23
36-506 • Type SHD-CGC 3/C • 5000 Volts
Primary UsageRecommendation
Longwall Miner
ContinuousMiner
1Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
2Ground Check Conductor – 16 AWG tinned copper conductor, designed to withstand extreme flexing andbe extensible, insulated with yellow polypropylene.
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – +8%/-5% of nominal outside diameter
SizeAWG
2/0 3/0 4/0350
SizeAWG
5 4 3 1
No. of Wiresper
Conductor
323418 532888
No. of Wiresper
Conductor
133259 259259
InsulationThickness
mils
110110110120
NominalOutside
Dimensions in.
2.200 2.360 2.500 2.950
Jacket Thickness
mils
220 235 235 265
Approx.Weightlbs. per1,000 ft.
3716 4130 5190 7571
Ampacity*40°C
Ambient Temp
243 279 321 435
Power Conductors Grounding Conductors
36-506-
020 030 040 350
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.901Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961324
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-510
Type SHD Flat 3/CMold-cured Jacket • 2000 Volts
ApplicationHeavy duty portable power cable for use in circuits not exceeding 2,000 volts. Especiallydesigned for use on continuous miners requiringgrounding conductors and metallic shieldingover each conductor. Recommended maximumcontinuous conductor temperature is 90°C.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.Reinforcement
Jacket1
Mold-cured thermosetwith cable identification via permanent marking.
ConductorsFlexible tinned copper
Insulation90°C ethylene-propylenerubber (EPR)
Insulation ShieldingTinned copper and textile braid
Separator Tape
Cross-section
� Mine Safety & Health Administration 184-MSHA.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
� Pennsylvania Department of Environmental Protection P-184.
Ratings & Approvals
Photo courtesy Joy Mining Equipment
Ground WiresFlexible tinnedcopper coveredwith semi-conductivethermoset compound
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 25
*Ampacity – Based on continuous duty at 90°C conductor temperature.
1Jacket – Extra-Heavy-Duty black neoprene is standard.
Tolerances – ± 0.050 inch minor dimension± 0.080 inch major dimension
SizeAWG
2/0
SizeAWG
3
36-510-
020
No. of Wiresper
Conductor
329 7x47
No. of Wiresper
Conductor
204 6x34
InsulationThickness
mils
80
NominalOutside
Dimensions in.
1.205 x 2.970
Approx.Weightlbs. per1,000 ft.
3600
Ampacity*40°C
Ambient Temp
243
Power Conductors Grounding Conductors
36-510 • Type SHD Flat 3/C • 2000 Volts
Primary UsageRecommendation
ContinuousMiner
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.901Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961326
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-515
Type SHD-GC 3/CMold-cured Jacket • 5000 Volts
ApplicationHeavy duty portable power cable for use in circuits not exceeding 5,000 volts (see nextpage for continuous miner circuit requirementsexceeding 2000 volts). Designed for applica-tions such as longwall shearers, continuousminers and mobile equipment such as shovels,dredges and drills. Recommended maximumcontinuous conductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating acceptance as flame resistant by thePennsylvania Department of EnvironmentalProtection and the Mine Safety and HealthAdministration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58.Tiger® Brand Cable meets or exceeds ASTM B-172 and B-33. Suitable for shallowwater submersion.
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
TapeNon-conducting
Insulation90°C ethylene-propylenerubber (EPR)
Ground WiresFlexible tinned copper
Strand ShieldSemi-conducting layer
Ground Check Conductor2
Flexible tinned copper with yellow polypropylene insulation
Round-shaped cross-section
InsulationShieldingTinned copperand color codednylon braid
Assembly Taped core
Separator Tape
See Page 42 for jacket color options.
Also available with Extra-Tough ThermoplasticPolyurethane (TPU) jacketfor extremely abrasiveenvironments! See Pg. 42
See Page 40-41 for Tiger Stripe options
Tiger® Brand cables come in six colors for safe, easy circuit identification. See page 42 for details.
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-7K-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.
� Canadian Standards Association File 82346, FT1, FT5, -50°C Type SHD-GC, SHD-BGC up to 25kVType W, G, G-GC, G-BGC up to 2kV
� Canadian Standards Association Type SHD-GC FT4
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 27
36-515 • Type SHD-GC 3/C • 5000 Volts
Primary UsageRecommendation
Longwall Miner
1Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
2Ground Check Conductor – 8 AWG (minimum 133 strand 7x19) ground check conductor on 6 AWG through 4/0 AWG cable.
6 AWG (minimum 133 strand 7x19) ground check conductor on 250 kcmil and larger cable.
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – +8%/-5% of nominal outside diameter
SizeAWG
6 4 2 1 1/0 2/0 3/0 4/0250350500
SizeAWG
10 8 6 5 4 3 2 1 1/0 2/0 4/0
No. of Wiresper
Conductor
133259259259266323418 532627888
1221
No. of Wiresper
Conductor
49133133133259259259 259266323532
InsulationThickness
mils
110110110110110110110110120120120
NominalOutside
Dimensions in.
1.56 1.68 1.87 1.95 2.08 2.20 2.36 2.50 2.69 2.95 3.31
Jacket Thickness
mils
185 185 205 205 220 220 235 235 250 265 280
Approx.Weightlbs. per1,000 ft.
1560 1920 2500 2860 3390 3830 4418 5300 6450 788010440
Ampacity*40°C
Ambient Temp
93 122 159 184 211 243 279 321 355 435 536
Power Conductors Grounding Conductors
36-515-
006 004 002 001 010 020 030 040 250 350 500
ContinuousMiner
2300VContinuous MinerApplicationsExtra heavy duty orange/green jacketed portable power cablefor use in continuous miner circuits exceeding 2,000 volts.
Recommended maximum continuous conductortemperature is 90°C.
Cable carries “P-184-MSHA” marking indicating acceptance asflame resistant by the Pennsylvania Department of EnvironmentalProtection and the Mine Safety and Health Administration.
Tiger® Brand Mining Cable meets or exceeds ICEA StandardsS-75-381/NEMA WC-58.
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.901Tables reproduced from standards publication
ICEA-S-75-381, NEMA WC-58
See Page 13 for AWG/MetricCross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961328
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-516
Type SHD-PCG • LongwallMold-cured Jacket • 5000 Volts
ApplicationHeavy duty portable power cable designed foruse on longwall shearers, where three shieldedpower conductors, three unshielded controlconductors, and a grounding conductor arerequired. Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating acceptance as flame resistant by thePennsylvania Department of EnvironmentalProtection and the Mine Safety and HealthAdministration.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-172 and B-33.
Ground ConductorFlexible tinned copper located in the center of the cable
Jacket1
Reinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
ConductorsFlexible tinned copper
TapeNon-conducting
Insulation90°C ethylene-propylenerubber (EPR)Control Group 3 Conductors
Flexible tinned copperethylene polypropylene rubberinsulation color coded black,white, red and an overall thermosetting jacket
Round-shaped cross-section
Strand ShieldSemi-conductinglayer
Insulation ShieldingTinned copper and color-coded nylon braid
Separator TapeNon-conducting
See Page 42 for jacketcolor options.
PureIntegral Fillfor greatertorsion
resistance
PureIntegral Fill
Photo courtesy 20 Mile Coal Mine
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-7K-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381.
Ratings & Approvals
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 29
36-516 • Type SHD-PCG 3/C • 5000 Volts
Primary UsageRecommendation
Longwall Miner
*Ampacity – Based on continuous duty at 90°C conductor temperature.
1Jacket – Extra-Heavy-Duty (EHD) black CPE is standard. Colored EHD CPE jacketsavailable upon request. See page 42.
Tolerances – +8%-5% of nominal outside diameter
SizeAWG
2 1/0 2/0 3/0 4/0
SizeAWG
4 3 2 1 1/0
SizeAWG
8 8 8 8 6
No. of Wiresper
Conductor
259266323418532
No. of Wiresper
Conductor
168222246259426
No. of Wiresper
Conductor
133133133133133
NominalOutside
Dimensions in.
2.03 2.27 2.45 2.58 2.76
Approx.Weightlbs. per1,000 ft.
2769 3571 3774 4752 6030
Ampacity*40°C
Ambient Temp
159 211 243 279 321
36-516-
002 010 020 030 040
Power Conductors Grounding Conductors Control Conductors
Factory InstalledCable Assemblies
See pages 44-45 for moreinformation.
SAVETIME &MONEY
Correction FactorsFor ampacities for various ambienttemperatures above or below 40°C.1
Ambient Temp. Multiplying Degrees C Correction Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.901Tables reproduced from standards publicationICEA-S-75-381, NEMA WC-58
Nearest StandardMetric Cond.
mm2
0.50 0.50 1.00 1.50 2.50 4 6 10 16 25 35 50 50 70 95 120 120 150 185 240 240 300 400 400 500
Area ofAWG/kcmilin mm2
0.35 0.52 0.82 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.43 85.01 107.2 126.7 152.0 177.3 202.7 253.4 304.0 380.0 405.4 506.7
AWG/kcmilSize
22 20 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 800 1000
AWG/Metric Cross Reference
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961330
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-601/602/604
Type MP-GC 3/C • Mine Power Feeder • 5/8/15kVMold-cured Jacket • 100% Level (Grounded)
ApplicationConnections between units of mine distributionsystems not exceeding the rated voltage wheninstalled in duct, conduit or open air and for direct burial in wet and dry locations.Recommended maximum continuous conductor temperature is 90°C.
Cable carries “P-7K-184-MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-8 and B-33.
Jacket1
Mold-cured thermosettingChlorinated Polyethylene(CPE) Jacket. Cable identification via permanent marking.
ConductorsCopper
Insulation90°C ethylene-propylenerubber (EPR)
Ground WiresTinned copper
Strand ShieldSemi-conducting layer
Ground Check Conductor8 AWG 7-wire copper with yellow polypropylene insulation
Round-shaped cross-section
InsulationShieldingSemi-conductinglayer undercopper tape(phase identification provided)
Assembly Taped core
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-7K-184.
� Insulated Cable Engineers Association S-75-381. Design standard for miningcables.
Ratings & Approvals
See Page 42 for jacketcolor options.
Cable may be suspendedvertically by using amessenger and specialmechanical connectors.
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 31
5000 Volts • 36-601 • Type MP-GC 3/C
8000 Volts • 36-602 • Type MP-GC 3/C
15000 Volts • 36-604 • Type MP-GC 3/C
Primary UsageRecommendation
1Jacket – CPE jacket. Black is standard. Colored CPE jackets available upon request. See page 42.
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – + 8%/-5% of nominal outside diameter
SizeAWG
4 2 1 1/0 2/0 4/0250350500
SizeAWG
8 6 5 4 3 1 1/0 2/0 4/0
No. of Wiresper
Conductor
7719191919373737
No. of Wiresper
Conductor
7 7 7 7 7 19 19 19 19
InsulationThickness
mils
909090909090909090
NominalOutside
Dimensions in.
1.42 1.56 1.65 1.76 1.88 2.14 2.23 2.47 2.70
Jacket Thickness
mils
110 110 110 110 110 140 140 140 140
Approx.Weightlbs. per1,000 ft.
1441 1827 2168 2602 3010 4190 4825 6062 8427
Ampacity*40°C
Ambient Temp
122 159 184 211 243 321 355 435 536
Power Conductors Grounding Conductors
36-601-
004 002 001 010 020 040 250 350 500
SizeAWG
4 2 1 1/0 2/0 4/0250350500
SizeAWG
8 6 5 4 3 1 1/0 2/0 4/0
No. of Wiresper
Conductor
7719191919373737
No. of Wiresper
Conductor
7 7 7 7 7 19 19 19 19
InsulationThickness
mils
115115115115115115115115115
NominalOutside
Dimensions in.
1.54 1.66 1.78 1.89 2.03 2.28 2.31 2.58 2.88
Jacket Thickness
mils
110 110 110 110 110 140 140 140 140
Approx.Weightlbs. per1,000 ft.
1608 1919 2507 2660 3257 4382 4965 6484 8857
Ampacity*40°C
Ambient Temp
122 159 184 211 243 321 355 435 536
Power Conductors Grounding Conductors
36-602-
004 002 001 010 020 040 250 350 500
SizeAWG
2 1 1/0 2/0 4/0250350500
SizeAWG
6 5 4 3 1 1/0 2/0 4/0
No. of Wiresper
Conductor
719191919373737
No. of Wiresper
Conductor
7 7 7 7 19 19 19 19
InsulationThickness
mils
175175175175175175175175
NominalOutside
Dimensions in.
1.98 2.11 2.18 2.30 2.54 2.61 2.80 3.15
Jacket Thickness
mils
110 110 110 110 140 140 140 170
Approx.Weightlbs. per1,000 ft.
2517 3023 3296 3679 5146 5618 7055 9405
Ampacity*40°C
Ambient Temp
164 187 215 246 325 359 438 536
Power Conductors Grounding Conductors
36-604-
002 001 010 020 040 250 350 500
Mine Power Feeder
Horizontal
Mine PowerFeederVertical
Note:Cable maybe suspendedvertically byusing amessengerand specialmechanicalconnectors.
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961332
Tiger® Brand is a registered trademark of AmerCable Incorporated.
36-621/622/624
Type MP-GC 3/C • Mine Power FeederPVC Jacket • 100% Level (Grounded)
ApplicationConnections between units of mine distributionsystems not exceeding the rated voltage wheninstalled in duct, conduit or open air. For directburial in wet and dry locations. Recommendedmaximum continuous conductor temperatureis 90°C.
Cable carries “P-7K-184-MSHA” marking indicating listing by the Mine Safety and HealthAdministration and the Pennsylvania Departmentof Environmental Protection.
Tiger® Brand Mining Cable meets or exceedsICEA Standards S-75-381/NEMA WC-58,ASTM B-8 and B-33.
Jacket1
Polyvinyl chloride (PVC),cable identification via permanent surface marking.
ConductorsCopper
Insulation90°C cross-linked polyethylene
Strand ShieldSemi-conducting layer
Ground Check Conductor8 AWG 7-wire copper with yellow polypropylene insulation
Round-shaped cross-section
InsulationShieldingSemi-conductinglayer undercopper tape(phase identification provided)Fillers
Assembly Taped core
Ground WiresTinned Copper
Binder Tape
PVC jacket color optionsare the same as CPE. See Page 42
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-7K-184.
� Tiger® Brand Mining Cables meet or exceed ICEA Standards S-75-381 & CSA Standards C 22.2 #96.1
� Canadian Standards Association File 82346, FT1, FT5, -35°C Type MP-GC, MPF up to 25kV
Ratings & Approvals
MPF 970’ verticaldeploymentusing a singlemessenger.Ask yourrep fordetails.
MPF 970’ verticaldeploymentusing a singlemessenger.Ask yourrep fordetails.
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 33
5000 Volts • 36-621 • Type MP-GC 3/C
8000 Volts • 36-622 • Type MP-GC 3/C
15000 Volts • 36-624 • Type MP-GC 3/C
Primary UsageRecommendation
1Jacket – PVC
*Ampacity – Based on continuous duty at 90°C conductor temperature.
Tolerances – + 8%/-5% of nominal outside diameter
SizeAWG
4 2 1 1/0 2/0 4/0250350500
SizeAWG
8 6 5 4 3 1 1/0 2/0 4/0
No. of Wiresper
Conductor
7719191919373737
No. of Wiresper
Conductor
7 7 7 7 7 19 19 19 19
InsulationThickness
mils
909090909090909090
NominalOutside
Dimensions in.
1.42 1.56 1.65 1.76 1.88 2.14 2.23 2.47 2.70
Jacket Thickness
mils
110 110 110 110 110 140 140 140 140
Approx.Weightlbs. per1,000 ft.
1224 1653 1950 2200 2721 3845 4321 5652 7721
Ampacity*40°C
Ambient Temp
122 159 184 211 243 321 355 435 536
Power Conductors Grounding Conductors
36-621-
004 002 001 010 020 040 250 350 500
SizeAWG
4 2 1 1/0 2/0 4/0250350500
SizeAWG
8 6 5 4 3 1 1/0 2/0 4/0
No. of Wiresper
Conductor
7719191919373737
No. of Wiresper
Conductor
7 7 7 7 7 19 19 19 19
InsulationThickness
mils
115115115115115115115115115
NominalOutside
Dimensions in.
1.54 1.66 1.78 1.89 2.03 2.28 2.31 2.58 2.88
Jacket Thickness
mils
110 110 110 140 140 140 140 140 140
Approx.Weightlbs. per1,000 ft.
1366 1727 2174 2656 2895 3983 4484 5827 7893
Ampacity*40°C
Ambient Temp
122 159 184 211 243 321 355 435 536
Power Conductors Grounding Conductors
36-622-
004 002 001 010 020 040 250 350 500
SizeAWG
2 1 1/0 2/0 4/0250350500
SizeAWG
6 5 4 3 1 1/0 2/0 4/0
No. of Wiresper
Conductor
719191919373737
No. of Wiresper
Conductor
7 7 7 7 19 19 19 19
InsulationThickness
mils
175175175175175175175175
NominalOutside
Dimensions in.
1.98 2.11 2.18 2.30 2.54 2.61 2.80 3.15
Jacket Thickness
mils
140 140 140 140 140 140 140 170
Approx.Weightlbs. per1,000 ft.
2021 2503 2658 3066 4369 4875 6412 8610
Ampacity*40°C
Ambient Temp
164 187 215 246 325 359 438 536
Power Conductors Grounding Conductors
36-624-
002 001 010 020 040 250 350 500
Mine Power Feeder
Horizontal
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961334
36-202-018
Longwall Signal Cable2-9 Conductors • 50 Volts
ApplicationA flexible signal cable for use in Longwall and other undergroundmining applications. The TPU jacket provides extra-tough physical characteristics needed in the underground mining environment. Cable is available with full copper braid shieldingupon request.
JacketThermoplastic Polyurethane(TPU)
Power ConductorsExtra flexible stranded per ASTM B-174
Round-shaped cross-section
InsulationChemically cross-linked, non-chlorinated thermosetting, flame retardant polyolefin
Ratings & Approvals� 90°C Temperature Rating � Tiger® Brand Mining Cables materials
meet or exceed industry specifications
� Mine Safety and Health Administration07-KA - - MSHA
� Pennsylvania Department ofEnvironmental Protection P-07-KA
Colors Available:Black (standard)Orange (optional)
Tolerances – ± 5% of nominal outside diameter
SizeAWG
18 18 18 18 18 18 18 18 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 10
Number of
Conductors
2345678923456789234567892345678923456789
PartNumber36-
202-018203-018204-018205-018206-018207-018208-018209-018202-016203-016204-016205-016206-016207-016208-016209-016202-014203-014204-014205-014206-014207-014208-014209-014209-012209-012209-012209-012209-012209-012209-012209-012209-010209-010209-010209-010209-010209-010209-010209-010
DiameterOver
Insulation (Inches)
0.1150.1150.1150.1150.1150.1150.1150.1150.1250.1250.1250.1250.1250.1250.1250.1250.1400.1400.1400.1400.1400.1400.1400.1400.1600.1600.1600.1600.1600.1600.1600.1600.1800.1800.1800.1800.1800.1800.1800.180
OverallDiameter(Inches)
0.4400.4600.4900.5200.5600.5600.6300.6600.4600.4800.5100.5500.5900.5900.6600.6900.4900.5100.5500.5900.6300.6300.7100.7500.5260.5550.5960.6420.6900.6900.7700.8150.5700.5980.6450.6960.7500.7500.8350.875
Weight(lbs./ft.)
0.0870.1000.1170.1360.1560.1630.1970.2150.0990.1140.1330.1580.1830.1900.2250.2470.1180.1380.1660.1960.2250.2380.2780.3000.1480.1770.2130.2540.2970.3160.3880.4260.1860.2260.2760.3310.3910.4620.5190.626
These cables are also availablewith MSHA approved fiber optics.See Page 42 for fiber opticinformation.
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 35
36-202-118
Underground Lighting Cable2-9 Conductors • 110 Volts
ApplicationA flexible insulated cable for use in mine lighting systems. The TPU jacket provides extra-tough physical characteristics needed in the underground mining environment. Cable is available with full copper braid shielding upon request.
JacketThermoplastic Polyurethane(TPU)
Power ConductorsExtra flexible stranded per ASTM B-174
Round-shaped cross-section
InsulationChemically cross-linked, non-chlorinated thermosetting, flame retardant polyolefin
� 90°C Temperature Rating
� Tiger® Brand Mining Cables materials meet or exceed industry specifications
Ratings
Colors Available:Black (standard)Orange (optional)
Tolerances – ± 5% of nominal outside diameter
SizeAWG
18 18 18 18 18 18 18 18 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 10
Number of
Conductors
2345678923456789234567892345678923456789
PartNumber36-
202-118203-118204-118205-118206-118207-118208-118209-118202-116203-116204-116205-116206-116207-116208-116209-116202-114203-114204-114205-114206-114207-114208-114209-114202-112203-112204-112205-112206-112207-112208-112209-112202-110203-110204-110205-110206-110207-110208-110209-110
DiameterOver
Insulation (Inches)
0.1150.1150.1150.1150.1150.1150.1150.1150.1250.1250.1250.1250.1250.1250.1250.1250.1400.1400.1400.1400.1400.1400.1400.1400.1600.1600.1600.1600.1600.1600.1600.1600.1800.1800.1800.1800.1800.1800.1800.180
OverallDiameter(Inches)
0.4400.4600.4880.5200.5600.5600.6400.6600.4600.4800.5120.5500.5900.5900.6700.6900.4900.5100.5500.5880.6300.6300.7200.7550.5260.5550.5960.6420.6900.6900.7700.8150.5700.5980.6450.6980.7500.7500.8350.875
Weight(lbs./ft.)
0.0870.1000.1160.1350.1560.1630.1980.2150.1060.1140.1340.1580.1830.1910.2250.2470.1190.1380.1660.1950.2250.2380.2780.3020.1480.1770.2130.2540.2970.3160.3880.4260.1860.2260.2760.3310.4010.4620.5190.626
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961336
37-119
Flexible Power Cable • DLOEP/CPE • RHH, RHW-2 • 2000 Volts
ApplicationNexans AmerCable’s 2000V Diesel Locomotive Cable (DLO) is a single conductor portable power cable suitable for use inapplications needing great flexibility and excellent durability.Applications include motor and generator leads, battery leads,shipyards, telecommunications power, heavy earth movingequipment and renewable energy applications.
Features� A two layer composite of flame retardant, oil and sunlight
resistant Chlorinated Polyethylene (CPE) outer layer andEthylene-Propylene rubber (EPR) inner layer. Compositedesign provides significant diameter reductions compared todesigns using full thickness jackets.
� Suitable for continuous operating temperatures of 90°C, wet or dry
� Rated RHH, RHW-2; 2/0 – 1111 kcmil listed and marked “for CT use”
� UL listed as Sunlight Resistant
� UL listed as Marine Shipboard Cable (4/0 and larger) Special order only
� Insulation and jacket meet hazardous waste regulations, perCode of Federal Regulations 40 Section 261 (40CFR261) forcharacteristic lead content
� Flame Resistance: FT-4/IEEE1202 for 2/0 1111 kcmil and UL VW-1
� Meets smoke release and other requirements of VerticalCable Tray Test UL 1685 and is marked “ST-1” for 2/0 – 1111 kcmil
JacketFlame retardant, oil and sunlight retardant thermosetChlorinated Polyethylene (CPE)
See Page 34for jacketcolor options.
Round-shaped cross-section
Ratings & Approvals
InsulationEthylene-Propylene rubber (EPR)
ConductorFlexible-stranded, tin-coated annealedcopper
SeparatorSuitable separator tape provides easy stripping of insulation
Extremely flexible strandingfor increased overall cable
flexibility and ease of installation
� UL Standard 44: Thermoset Insulated Wires &Cables, Types RHH, RHW-2. UL VW-1.
� UL Standard 1685: Vertical Tray Fire propagation and Smoke Release Test forElectrical and optical Fiber Cables. (UL, LS)
� AAR 591 Wire and Cable Insulating Material:Strand Construction except 3/0 and 4/0.
� ASTM B-33: Standard Specification for TinnedSoft or Annealed Copper Wire for ElectricalPurposes.
� ASTM B-172: Standard Specification for Rope-Lay-Stranded Copper Conductors havingBunch-Stranded Members, for ElectricalConductors.
� MSHA P-184
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 37
*Ampacity – Calculated with at 90°C conductor temperature and 30°C ambient air, per2002 NEC, Table 310-17
• Cable diameters are subject to +/-5% manufacturingtolerance
• Sizes above 1000 kcmil are not UL listed
37-119 • Portable Power Cable • 2000 Volts
201 14 19 0.045 0.015 0.214 31 35 202 12 19 0.045 0.015 0.233 41 40 203 10 27 0.045 0.015 0.257 58 55 204 8 37 0.055 0.030 0.326 86 80 205 6 61 0.055 0.030 0.365 124 105 207 4 105 0.055 0.030 0.460 198 140 209 2 147 0.055 0.030 0.498 261 190 210 1 224 0.065 0.045 0.618 400 220 211 1/0 266 0.065 0.045 0.664 468 260 212 2/0 323 0.065 0.045 0.704 561 300 213 3/0 418 0.065 0.045 0.789 725 350 214 4/0 532 0.065 0.045 0.839 888 405 215 262 646 0.075 0.065 0.973 1048 467 216 313 777 0.075 0.065 1.029 1227 522 217 373 925 0.075 0.065 1.094 1436 591 218 444 1110 0.075 0.065 1.169 1691 652 219 535 1332 0.090 0.065 1.295 2034 728 220 646 1591 0.090 0.065 1.368 2395 815 221 777 1924 0.090 0.065 1.488 2837 904 222 929 2318 0.090 0.065 1.583 3448 1005 223 1111 2745 0.130 0.065 1.707 4156 1119
Approx.Weightlbs. per1,000 ft.
Ampacity*90°C
Part No.37-119-
SizeAWG/kcmil
MinimumWires perConductor
NominalInsulationThickness
in.
NominalJacket
Thickness in.
NominalOutside Diameter
in.
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961338
36-501
VFD Power Cable • Shielded • 2000 Volts3 Conductors + 3 Grounds + Ground Check(s)
ApplicationA flexible, braid and foil shielded, 2kV powercable specifically engineered for use in variablefrequency AC motor drive (VFD) applications.
Cable carries “P-184-MSHA” marking indicatingacceptance as flame resistant by the PennsylvaniaDepartment of Environmental Protection and theMine Safety and Health Administration.
Tiger® Brand Mining Cable materials meet orexceed ICEA Standard S-75-381/NEMA WC-58for Type SHC constructions. ASTM B-172 and B-33.
Ratings & Approvals� 90˚C Temperature Rating� Tiger® Brand Mining Cable materials
meet or exceed ICEA Standard S-75-381/NEMA WC-58.
� Mine Safety & Health Administration 7K-184-MSHA.
� Pennsylvania Department of Environmental Protection P-7K-184.
� Canadian Standards AssociationFile 82346 2kVCSA Phase Color ID available on MTO
JacketReinforced mold-cured thermosetting ChlorinatedPolyethylene (CPE) Jacket.Cable identification via permanent marking.
See Page 34 for jacket color options.
Ground Conductors (x3)Flexible tinned rope stranded conductors perASTMB-172 and B-33,Insulated and colored green
Ground Check1
Wire(s) OptionalFlexible tinnedcopper with yellow insulation.Center groundcheck available
ShieldOverall tinned copper braid plus aluminum/polyester tape providing100% coverage
InsulationType II EPDM (EPR) suitablefor continuous operation at90°C. Ozone resistant.
Round-shaped cross-section
Power ConductorExtra flexibletinned ropestranded conductors perASTM-172 and B-33
• Tolerance = +/- 5% of nominal outside diameter.1Ground Check Conductor – #16 AWG extensible strand for center groundcheck.
#14 AWG is the minimum size for non-center ground check wires*Ampacity Ratings – based on continuous duty at 90°C conductor temperature
002 2 8 0.155 1.43 1790 159 001 1 7 0.170 1.64 2150 184 010 1/0 6 0.170 1.74 2550 211 020 2/0 5 0.190 1.89 3100 243 030 3/0 4 0.190 2.01 4050 279 040 4/0 3 0.220 2.17 4390 321 250 250 3 0.220 2.40 5950 355 350 350 1 0.220 2.68 7840 405 500 500 1 0.265 3.03 9730 536
Part No.36-501-
PowerConductor
SizeAWG/kcmil
NominalJacket
Thicknessin.
GroundingConductorsSize AWG1
NominalDiameter
in.
Approx.Weightlbs./ft.
Ampacity*90°C
CorrectionFactorsFor ampacities for various ambienttemperatures above or below 40°C. Ambient Multiplying Temp. Correction Degrees C Factors
10 1.26 20 1.18 30 1.10 40 1.00 50 0.90
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 39
Other Available Nexans AmerCableVFD Cable Constructions
37-102VFD
Standard Type VFD
Power Cable• 2kV• Rated 110°C• Gexol® Insulated
37-102VFD
Low SmokeHalogen-FreeType VFD
Power Cable• 2kV• Rated 110°C• Gexol® Insulated
37-108VFD
FlexibleType TC-ER
VFD Power Cable• 600V• Rated 90°C
VFD CABLE
MOTORMOTORUV
WPE
R
S
T
PE
VFDVFD
V LL
37-102VFD
CIR Type VFD Power Cable• 2kV• Rated 110°C• Gexol® Insulated• Crush & Impactresistant withoutexternal armoring
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961340
Tiger Stripes – Reflective
Nexans AmerCable’s reflective Tiger Stripes can extend cable life by reducing run-overs in low visibility situations and improve mine safetyby providing easier visual circuitidentification.
Black(standard)
Blue Green Orange Yellow Red
� Increased safety for personnel through easiercircuit identification
� Available on CPE round jacketed cables only.
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 41
Black/Red Blue/White Yellow/Red Orange/Green Red/White Green/White
Black/White Blue/Green Yellow/Green Orange/White Red/Blue Black/Green
Nexans AmerCable’s standard Tiger Stripesprovide additional color combinations byvulcanizing a contrasting colored stripe intothe jacket of our round CPE cables.
Shown below are a few examples of the many possible jacket / stripe combinations.
Consult with your AmerCable rep or thefactory for a complete list of availablestripe options.
Available onlyfrom NexansAmerCable
Safetythrough easier
circuitidentification
Assign to specificequipment tomake visual
inventory simpler
Available onlyon round CPEjacketed cables
Tiger Stripes – Standard
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961342
Nexans AmerCable TPU JacketsFor extremely abrasive environments, AmerCable’sThermoplastic Polyurethane (TPU) jacket providesthe extra-tough physical characteristics needed in the roughest mining environments.Compared to Nexans AmerCable’s standardCPE jacketing material, TPU provides:
5X more abrasion resistance
2X more tear resistance
2X more tensile strength
Nexans AmerCable CPE JacketsNexans AmerCable’s thermoset ChlorinatedPolyethylene jacket provides the physical performanceand strength needed to resist wear, tear, abrasion andcompression cuts caused by everyday mining use.
This tough, durable jacket is a proven performer in mines throughout the world. Nexans AmerCable’s engineered cable construction includes a taped-core,integral fill and tandem extrusion of the jacket layers.Two-pass jackets, extruded in tandem, yield an inseparable bond between the layers. Integral fillingof the cable core reduces torsion-induced damage.
Black(standard)
Blue Green Orange Yellow RedBlack(standard)
Blue Green Orange Yellow Red
Colored jacketsmaintain physicalproperties equal to the standardblack jacket.
Up to8% LessJacketWeight
Jacket Materials & Color Options
These brightlycolored cablescan improve
minesafety byproviding
easy circuitidentification.
Composite Signal CableNexans AmerCable has a unique composite Signal Cable design in which any MSHA approved fiberoptic may be added. These products are cabled for the optimum signaling capabilities and fiber opticperformance. The overall Thermoplastic Polyurethane (TPU) jacket has the highest resistance to abrasion and cuts and offers excellent protection for the fiber.
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 43
Safety, Training& Education
Field Technical SupportSafety and maximized cable productivity are NexansAmerCable’s top priorities for our customers. Surface or underground – 24/7 – all shifts – NexansAmerCable’s mine-experienced field reps are ready to provide on-site cable evaluation, safe handlingtraining and innovative productivity solutions.
A few extra minutes spent in cable repair can save hours of costly downtime.
Cable Splicing TrainingOur field reps can conduct on-site training (all shifts) on the correct way to splice cables to extend their service life.
MineCable-Safe is an investment in Safety and Productivity that brings the knowledge and experience of ourfield engineers to your mine. High voltage cables require special handling to get maximum service life andkeep personnel safe. Can you identify the difference between a productivity problem and a safety issue? Our experts can. We deliver a highly-valuable report that clearly identifies safety and productivity issues. The report includes recommendations on how to deploy, move and utilize cables more safely and to makeyour mine more productive. Follow-up can also include training sessions and engineered solutions.
Manufactured by Nexans AmerCable • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961344
Why Use
CableAssemblies?� Your cable assembly,
built to your exact specifications, arrives ready for immediate use
� Reduced prep, handlingand installation time
� No need to maintain expensive connectorinventory
� Professionally assembled
� Factory electrical testingafter termination
� Nexans AmerCable’s on-time delivery rate and short lead times are#1 in the cable industry
Factory Installed Cable Assemblies from Nexans AmerCable are professionally assembled in our El Dorado, Arkansas manufacturingfacility. Our team of experienced handlers join cables and connectorsthat match your exact specifications. Our assemblies are designed toperform in your harshest operating conditions.
Factory prepared cable assemblies or terminations are a reliable way to lower your overall cable connectivity costs through enhanced reliability, reduced handling and lower installation time.
FACTORYINSTALLED
Constructions� 2 - 25kV� Stress Cones & fill� ID Labeling� Pothead Assemblies
Applications� Surface Mining� Underground Mining� Reeling
Factory InstalledCable Assemblies
LowerOverallCost
EnhancedReliability
ReducedInstallation
Time
350 Bailey Road • El Dorado, Arkansas USA • www.nexansamercable.com • e-mail: mining@nexansamercable 45
Molded Potheads
(up to 25kV)
Longwall RefurbishmentGet maximum service life fromyour Tiger®Brand longwall cables.
Our refurb team will expertly, clean, inspect,repair and splice in new sections as needed.
We then deliver them back to the mine – ready to power your longwall system.
Saves up to 60% when compared to the cost of a new longwall cable.
Before Refurb After Refurb
CouplersNexans AmerCable hasthe coupler you need forimmediate installation upon arrival.
Factory installed couplers fromNexans AmerCable are a reliable way to lower your overall cable connectivity costs.
Industrial VFD
Nexans AmerCable’s Mining & Industrial Cable Products & Services
Factory InstalledCable Assemblies
IndustrialIndustrial CIRSurfaceMining
350 Bailey Road • El Dorado, Arkansas USA(870) 862-4919 • (800) 643-1516 • Fax (870) 862-9613 • e-mail: [email protected]
www.nexansamercable.com 10_14© 2014, AmerCable Incorporated
Nexans AmerCable is the leading global manufacturer ofsurface and underground mining cables.
Nexans AmerCable is an ISO 9001 certifiedcable manufacturer that combines leading-edgetechnology, proven manufacturing techniquesand high quality service to deliver the finestmining cable products available.
Nexans AmerCable serves a worldwide customer basefrom our manufacturing facility in El Dorado, Arkansas.Our professional field engineers and customer supportteam work directly, or in partnership with a network of independent distributors, to deliver productivity enhancing cable solutions.
What can you expect from Nexans AmerCable?� High-Quality Cable with an Emphasis on Safety
� On-Time Delivery
� Professional Sales, Support and Service
� Strategic Inventory Locations
� Short Lead Times El Dorado, Arkansas
Made in America