Indiana Meter Mounting Equipment Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Transcript
Page 1: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

IndianaMeter Mounting Equipment

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Page 2: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

2

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

MILBANKOVERVIEW

Milbank OverviewEnergy At Work since 1927

Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial, industrial, utility and transportation sectors. With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American manufacturer headquartered in Kansas City, Mo. For more information, please visit milbankworks.com.

As a market leader in electrical metering equipment, Milbank has set the standard for quality since 1927. Hundreds of configurations are available, including many sizes, knockout configurations, terminal configurations, bypass options, hubs, locks and connectors. Milbank has the socket you need with thousands of active products to meet your utility’s requirements.

Milbank doesn’t just build empty enclosures. We can deliver the entire package, complete with custom control equipment built to your exact specifications by our engineers. Milbank commercial pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures.

Milbank’s line of enclosures include commercial junction boxes, panel mount enclosures, transformer cabinets, wireway, trough and industrial panel mount and push-button enclosures. Built with high-quality craftsmanship and materials which meet or exceed industry standards, Milbank enclosures are made to protect controls and equipment from dust, dirt and other harmful elements found in a wide variety of environments.

METERING

ENCLOSED CONTROLS

ENCLOSURES

Page 3: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

3

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

TABLE OFCONTENTS

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Table of Contents

Air Conditioner Disconnects

30-60 amp AC disconnects .............................................................................................................................................. 660 amp AC disconnect with 20 amp GFCI receptacle ....................................................................................................... 7Hot tub disconnects .......................................................................................................................................................... 8

Single Position Sockets

125-200 amp, 4 terminal, ringless .................................................................................................................................... 9 200 amp, 4, 5 & 7 terminal, ringless, lever bypass ........................................................................................................ 10320 amp, 4 terminal, ringless, side wireway, lever bypass ............................................................................................. 11320 amp, 7 terminal, side wireway, ringless, lever bypass ............................................................................................ 12

Unmetered Load Centers

200 amp, unmetered load center with main breaker ...................................................................................................... 13

Meter Mains

125-200 amp, 4 terminal, ringless .................................................................................................................................. 14200 amp, 4 terminal, load center, ringless, horn bypass ................................................................................................ 15200 amp, 4 & 7 terminal, ringless, lever bypass ............................................................................................................. 16320 amp, 4 terminal, ringless, lever bypass ................................................................................................................... 17400 amp, 4 & 5 terminal, ringless ................................................................................................................................... 18400 amp, 7 terminal, ringless .......................................................................................................................................... 19200-400 amp, 4, 5 & 7 terminal, ringless ........................................................................................................................ 20

Multi-Position Sockets

150 amp, 4 terminal, ringless .......................................................................................................................................... 21200 amp, 4 terminal, ringless .......................................................................................................................................... 22Knockout information ..................................................................................................................................................... 23

Lever Bypass Multi-Position Sockets

200 amp, 5 terminal, ringless .......................................................................................................................................... 24200 amp, 7 terminal, ringless .......................................................................................................................................... 25

Multi-Position Meter Mains

125-200 amp, 4 terminal, ringless .................................................................................................................................. 26Knockout information ..................................................................................................................................................... 27125-200 amp, 4 terminal, ringless .................................................................................................................................. 28Dimensional information ................................................................................................................................................. 29

Page 4: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

4

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Table of Contents

Transformer Rated Sockets

20 amp, 6-13 terminal, plunger bypass .......................................................................................................................... 3020 amp, 6-13 terminal, test switch provision .................................................................................................................. 3180 amp, 6, 8 &13 terminal, lever bypass ....................................................................................................................... 32Test Switches ............................................................................................................................................................. 33-34Current transformer cabinet, panel enclosure ................................................................................................................ 35

Multi-Position Tap Box

3 phase, aluminum construction, wall or pad mountable ........................................................................................... 36-37

Meter Main with Load Center Pedestal

100-200 amp, 4 terminal, ringless ............................................................................................................................. 38-39

Temp Power

125 amp, 4 terminal, ringless .......................................................................................................................................... 40125 amp, surface mount, Millennium Series .................................................................................................................. 41125 amp, power outlet pedestal .................................................................................................................................... 42

Miscellaneous

Circuit Breakers ......................................................................................................................................................... 43-44Accessories ................................................................................................................................................................ 45-47Commercial Pedestals ................................................................................................................................................ 48-57Reference Information ............................................................................................................................................... 58-62Index .......................................................................................................................................................................... 63-65

MILBANKOVERVIEW

Page 5: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

5

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Catalog Number LogicHow our product catalog numbers are derived

CATALOGNUMBERLOGIC

U7040-RL-TG-KK-5T9-BL-AUT

Milbankdrawingnumber

Utilityspecific

designation

TG: Triplex groundQG: Quadplex ground

5th terminal designation5T6: installed at 6:005T9: installed at 9:00

U: UL ListedS: Non-UL Listed

UAP: UL, aluminum, painted KK: Horn bypass BL: Barrel lock

Hub Openings & Closing Plates-O Blank top-RL Small hub opening-R Large hub opening-XL Small closing plate-XT (2) Large Closking plates-XTL (2) Small closking plates-X Large closing plate-RXL Large hub opening adapted to small closing plate-RRL Large hub opening adapted to small hub opening

U2448-X-QG-5T9-K3-BLG-ARE

Milbankdrawingnumber

Utilityspecific

designation

TG: Triplex groundQG: Quadplex ground

5th terminal designation5T6: installed at 6:005T9: installed at 9:00

U: UL ListedS: Non-UL Listed

UAP: UL, aluminum, painted

Lugs (1Ø or 3Ø,350 or 600 kcmil)

Single: K1, K3, K5, K7Twin: K2, K4, K6, K8

BLG: Barrel lock / guard provision

-PXL Closing plate packed inside-WL 1” hub-YL 1¼” hub-ZL 1½” hub-DL 2” hub-EL 2½” hub-F 3” hub -G 3½” hub -H 4” hub

Page 6: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

6AC

DISCONNECTS

Air Conditioner Disconnects30-60 Amps | Fusible & Non-Fusible

Catalog Number

Amps TypeMax H.P.

Weight(lbs.)

Line/Load Wire Range Ground Wire

Range CU/ALDimensions Wire Rating

CU AL D" W" H" CU °C AL °C

U3802 60 Non-Fusible 10 3.25 #14-#2 #12-#2 #14-4 21⁄2 5 71⁄2 60°/75° 60°/75°

U3812 60 Non-Auto 10 3.25 #14-#2 #12-#2 #14-4 21⁄2 5 71⁄2 60°/75° 60°/75°

U3832 30 Fusible 3 2.5 #14-#3 #14-#3 #14-3 21⁄8 5 7 60°/75° 60°/75°

U3862 60 Fusible 10 3.3 #14-#3 #14-#3 #14-3 21⁄8 5 9 60°/75° 60°/75°

30–60 Amps | 1Ø 240 VAC | Air Conditioner Disconnects

Notes

• UL listed as Enclosed Pullout Switch• Type 3R rain resistant• One-inch concentric knockouts

U3832U3812U3802

Milbank’s air conditioner disconnect has a removable hinged cover for ease of installation. Our compact design meets NEC wiring space requirements and also complies with NEC article 440-14. For safe working conditions, our disconnect pullers may be removed and reinstalled in the OFF position. Additionally, padlock provisions are included on the front cover. As with other Milbank products, our enclosure is constructed of G90U galvanized steel and electrostatically finished with an attractive, light gray, baked powder coating. Our epoxy/polyester resin blend offers a finish that is both durable and fade-resistant.

Page 7: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

7

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Air Conditioner Disconnects20 Amp GFCI Receptacle

ACDISCONNECTS

CatalogNumber

TypeMax H.P.

Weight(lbs.)

Line/Load Wire Range

Ground Wire Range

CU/AL

Dimensions Wire Rating

CU AL D" W" H" CU °C AL °C

U3822-20GWR Non-Fusible 10 6 #14-#2 #12-#2 #14-4 44⁄5 51⁄4 72⁄5 60°/75° 60°/75°

60 Amps | 1Ø, 240 VAC | Air Conditioner Disconnect with GFCI Receptacle

Notes

• Disconnect Pullers: To ensure the safest conditions, Milbank disconnect pullers are reversible so they may be reinstalled in the OFF position.• Padlock Provision: All units are designed with a padlock provision on the cover for security.• *In-Use Cover: Cover is rated as an in-use cover (cover may be closed with cords plugged into receptacle).

• Meets NEC #210.63 requirements• UL listed as Power Outlet• Type 3R enclosure• In-use cover*• Duplex ground connector• 1" concentric knockouts

• 1Ø, 240 volt• 60 amp, non-fused• 20 amp GFCI receptacle• Reset/test button• Weather and tamper resistant• Meets NEC #406.8 requirements

SpecificationsU3822-20GWR

Page 8: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

8

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

HOT TUBDISCONNECTS

Hot Tub DisconnectsType 3R Enclosures

U4881-O-50GB U4881-O-60GB

Catalog Number

Breaker Amps

TypeWeight(lbs.)

Line/LoadWire Range

Ground Wire Range

CU/AL

Dimensions

CU AL D" W" H"

U4881-O-50GB 50 Breaker 8 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2

U4881-O-60GB 60 Breaker 8 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2

100 Amps | Hot Tub Disconnect or Sub Panel Breaker Enclosure | Type 3R

Specifications

• 240 volt ground fault protection• UL listed, Type 3R rain resistant• 2-pole, 50 or 60 amp GFCI breaker protection• Compact size• Three or four wire installation

• 1Ø, 120/240 VAC• Standard package of 12• Two extra one-pole breaker spaces• 100 amp overall rating• Easy to install

Page 9: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

9

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

125-200 AMPSINGLE

POSITION

Single Position Sockets125-200 Amp | 4 Terminal | Ringless | 600 VAC

Catalog Number Amps Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U7487-RL-TG-KK 125 OH/UG H.O. #6-2/0 #6-2/0 Horn 35⁄16 8 111⁄2 2 11⁄2 11⁄4 1⁄4

U7487-RL-TG-KK-BLG 125 OH/UG H.O. #6-2/0 #6-2/0 Horn 35⁄16 8 111⁄2 2 — 11⁄4 1⁄4

U7021-RL-TG-KK 200 OH H.O. #6-350 #6-350 Horn 41⁄8 8 151⁄2 21⁄2 1⁄4,1⁄2 1⁄4 —

U7021-RL-TG-KK-BLG 200 OH H.O. #6-350 #6-350 Horn 41⁄8 8 151⁄2 21⁄2 1⁄4,1⁄2 1⁄4 —

U7040-RL-TG-KK 200 OH/UG H.O. #6-350 #6-350 Horn 41⁄8 11 145⁄8 21⁄2 1⁄4,1⁄2 1⁄4 —

U7040-RL-TG-KK-BLG 200 OH H.O. #6-350 #6-350 Horn 41⁄8 11 145⁄8 21⁄2 1⁄4,1⁄2 1⁄4 —

U7040-XL-TG-KK 200 OH/UG C.P. #6-350 #6-350 Horn 41⁄8 11 145⁄8 21⁄2 1⁄4,1⁄2 1⁄4 —

U4532-XL 200 OH/UG C.P. #6-350 (2) #6-350 None 47⁄8 15 201⁄2 3 21⁄2 1⁄4,1⁄2 1⁄4

Catalog Number Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U1980-O-KK UG Blank #6-350 #6-350 Horn 41⁄2 13 151⁄4 3 21⁄2 11⁄2 1⁄4,1⁄2

U1980-O-KK-BLG UG Blank #6-350 #6-350 Horn 41⁄2 13 151⁄4 31⁄2 21⁄2 11⁄2 1⁄4,1⁄2

4 Terminal | Single Position | Ringless | 1Ø3W

200 Amp | 4 Terminal | Single Position | Ringless | Side Wireway | 1Ø3W

Notes

• Hubs: Order hubs separately — see accessory page for ordering information.• Fifth Terminal: For field mounted fifth terminal for U7021, U7040, U4532 and U1980, order catalog number K5T. For the U7487, order catalog number 5T8K2.• Connectors: Extruded aluminum connectors are tin plated.• U4532: Includes twin lug connector on load side.• Tap Connector: For tap connector, order K4977-INT.• Product numbers with BLG are used in AEP service areas.

7040

1 1

1

2 3

1 1

1

2 3

1 1BLG BOTTOM

74871

2 2

4

33

1

4

3 BLG BOTTOM

45321 1 1

2 2

34

70211 23

1 1

1

2 2

23 41980

U7487-RL-TG-KK U7040-RL-TG-KK U4532-XL U1980-O-KK

Page 10: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

10

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Single Position Lever Bypass200 Amp | 4, 5 & 7 Terminal | Ringless | 600 VAC

200 AMPSINGLE

POSITIONLEVER BYPASS

CatalogNumber

Terminal Phase Service HubConnectors

CU/ALDimensions Knockouts

D" W" H" 1 2 3 4

U3278-RL 4 1Ø3W OH H.O. #6-350 41⁄8 11 151⁄2 21⁄2 2 1⁄4,1⁄2 1⁄4

CatalogNumber

Terminal Phase Service HubConnectors

CU/ALDimensions Knockouts

D" W" H" 1 2 3 4

U9551-RRL 5 1Ø3W or 3Ø3W OH/UG H.O. #6-350 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

U9701-RRL* 7 3Ø4W OH/UG H.O. #6-350 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

U9701-X-QG-BLG* 7 3Ø4W OH/UG C.P. #6-350 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4

200 Amp | Single Position | Lever Bypass | Ringless | Non-Jaw Clamping

200 Amp | Single Position | Heavy Duty Lever Bypass | Ringless | Jaw Clamping

Notes

• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The lever on the U3278 unit operates the bypass device only; it does not provide clamping action on the meter spades. The levers on the U9551 and U9701 units supply clamping action on meter spades and also operate the bypass devices.• Product numbers with BLG are used in AEP service areas.* Can be used in a 100 A 3 phase applications due to lug range.

U3278-RL U9551-RRL U9701-RRL

1

1

1

22

3 4

3278 95519701

1

34

1 1 1

2

Page 11: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

11

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

320 AMPSINGLE

POSITIONLEVER BYPASS

Single Position Lever Bypass320 Amp | 4 Terminal | Ringless | 600 VAC

Catalog Number Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U4363-X-QG-K3-K2 OH C.P. (1) #4-600 or (2) 1/0-250 (2) #6-350 Lever 47⁄8 13 281⁄4 3 1⁄4,1⁄2 1⁄4 —

U1079-RRL-K3 OH H.O. (1) #4-600 or (2) 1/0-250

3⁄8" x 16 Studs Lever 47⁄8 13 383⁄4 3 21⁄2 1⁄4,1⁄2 1⁄4

U4905-X OH/UG C.P. 3⁄8" x 16 Studs 3⁄8" x 16 Studs Lever 53⁄4 16 383⁄4 4 31⁄2 3 1⁄4,1⁄2

U4905-X-BLG OH/UG C.P. 3⁄8" x 16 Studs 3⁄8" x 16 Studs Lever 53⁄4 16 383⁄4 4 31⁄2 3 1⁄4,1⁄2

U5161-X-K3L-K2L-BLG OH/UG C.P. (1) #4-600 or (2) 1/0-250 (2) #6-350 Lever 47⁄8 15 31⁄2 3 1⁄4,1⁄2 1⁄4 —

U1129-O-K3L-K2L UG Blank (1) #4-600 or (2) 1/0-250 (2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —

U1797-O-K3L-K2L UG Blank (1) #4-600 or (2) 1/0-250

(2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —

U1797-O-K3L-K2L-BLG UG Blank (1) #4-600 or (2) 1/0-250

(2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —

320 Amp Continuous (400 Amp Max) | 4 Terminal | Single Position | Ringless | 1Ø3W

Notes

• Side Wireway: U1797 and U4905 are side wireway units.• Bypass: Lever supplies clamping action and also operates bypass device.• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.• Connectors: Some units supplied with 3⁄8" x 16 hex head nuts with Belleville washers. For connector kits, order as extra

K1540 (single 600 kcmil). For twin lug connectors, order as extra K1350 (twin 350 kcmil). Order two kits to cover both line and load on U4905 and one kit for load side of U1079.

• Fifth Terminal: For factory-installed fifth terminal in the 6 o’clock position, add the suffix -5T6 to the catalog number. For factory-installed fifth terminal in the 9 o’clock position, add the suffix -5T9 to the catalog number. For field-installed fifth terminal, order as extra catalog number K3865 for U1129, U1797 and U4905 and K3866 for U1079.• Product numbers with BLG are used in AEP service areas.

U1797-O-K3L-K2L

1797

1 1

123

11

U1129-O-K3L-K2L

11295161

1 1

23

1 1 1

U1079-RRL-K3

10794363

1

111

2

34

4905

22

1 1

43

U4363-X-QG-K3-K2

1 1

111

23

Page 12: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

12

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Single Position Lever Bypass320 Amp | 7 Terminal | Ringless | 600 VAC

320 AMPSINGLE

POSITIONLEVER BYPASS

320 Amp | 7 Terminal | Single Position | Ringless | Side Wireway | 3Ø4W

Notes

• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.• Bypass: Lever supplies clamping action and also operates bypass device.• Connectors: Supplied with 3⁄8" x 16 hex head nuts with Belleville washers. For connector kits, order as extra K3441 (single 600 kcmil). For twin lug connectors, order as extra K3442 (twin 350 kcmil). Separate kits are required for both line and load. Line side connectors furnished on U2120.• Product numbers with BLG are used in AEP service areas.

2120 2594

U2120-X-K7 U2594-X

1

3

4

1

2

1

2

13

4

1

Catalog Number Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4

U2594-X OH/UG C.P. 3⁄8" x 16 Studs 3⁄8" x 16 Studs Lever 61⁄2 19 341⁄8 4 3 1 1⁄4

U2594-X-BLG OH/UG C.P. 3⁄8" x 16 Studs 3⁄8" x 16 Studs Lever 61⁄2 19 341⁄8 4 3 1 1⁄4

U2120-X-K7 UG C.P. (1) #4-600 or (2) 1/0-250

3⁄8" x 16 Studs Lever 61⁄2 173⁄4 313⁄4 4 3 1 1⁄4

Page 13: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

13

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Unmetered Load Centers200 Amp | 120/240 VAC

200 AMPUNMETERED

LOAD CENTERS

200 Amp | Unmetered Load Center with Main Breaker

Notes

• AIC Rating: This units are rated 22K AIC.• Breaker Interlock: U5971 accepts breaker interlock kits — order K5815 for large QN with small frame Q, K5820 for large frame QN with large frame QN, or K5830 for small frame Q to small frame Q.

Catalog NumberMain Breaker

AmpCircuits Service Hub

Dimensions Knockouts

D" W" H" 1 2 3 4 5

USE-22-200-MB 200 4 OH 2" 4 8 23 2 1 1⁄2,3⁄4 — —

U5971-XL-100 100 10 OH/UG C.P. 41⁄2 141⁄8 251⁄16 3 2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5971-XL-150 150 8 OH/UG C.P. 41⁄2 141⁄8 251⁄16 3 2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5971-XL-200 200 8 OH/UG C.P. 41⁄2 141⁄8 251⁄16 3 2 1 1⁄2,3⁄4 1⁄4,1⁄2

12

3 3

3

U5971-XL-200USE-22-200-MB

1 2

35 4

43 4

2

5971USE-22

Page 14: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

14

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

125 & 200 AMPMETER MAINS

Meter Mains125-200 Amp | 4 Terminal | Ringless | 120/240 VAC

Catalog Number Service Amp HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4 5

U3989-XL OH/UG 125 C.P. #6-2/0 CB None 33⁄4 11 22 2 1⁄4,1⁄2 — — —

U3491-XL-200 OH/UG 200 C.P. #2-350 CB None 41⁄8 12 29 21⁄2 2 1⁄4 — —

U5844-PXL-200-KK OH/UG 200 C.P. #6-350 CB Horn 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5844-PXL-200-KK-BLG OH/UG 200 C.P. #6-350 CB Horn 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2

4 Terminal | Meter Mains | Ringless | 1Ø3W

Notes

• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.• Breaker: For replacement breakers for U5844 order QN2200H. For U3989, order approved small frame breakers 125 amps or less per the rating label.• Fifth Terminal: For field installable fifth terminal kit, order K5T.• AIC Rating: The U5844 is 22K AIC rated.• PXL - Closing plate packed inside of carton.• Product numbers with BLG are used in AEP service areas.

34913989 5844

U5844-PXL-200-KKU3491-XL-200U3989-XL

1

1 1 2

3

1 1 1 2

35

3

3

4

4

4

4

2 2 21

1 1 2 1

1

Page 15: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

15

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

200 AMPMETER MAINWITH LOAD

CENTER

Meter Main With Load Center200 Amp | 4 Terminal | Ringless | 120/240 VAC

Catalog NumberBreaker Amps

Circuits Service HubConnectors CU/AL - Line

Dimensions

D" W" H"

U5168-XTL-100-KK 100 10 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5168-XTL-100-KK-BLG 100 10 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5168-XTL-150-KK 150 8 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5168-XTL-150-KK-BLG 150 8 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5168-XTL-200-KK 200 8 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5168-XTL-200-KK-BLG 200 8 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5268-XTL-150-KK 150 20 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5268-XTL-200-KK 200 20 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5268-XTL-200-KK-BLG 200 20 OH/UG C.P. #6-350 41⁄2 141⁄8 32

U5898-O-200-KK-BLG 200 8 OH/UG C.P. #6-350 41⁄2 17 341⁄2

U5898-O-100-KK-BLG 100 8 OH/UG C.P. #6-350 41⁄2 17 341⁄2

Knockouts

1 2 3 4 5 6

3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2

200 Amp | 4 Terminal | Meter Mains | Horn Bypass | Ringless | 1Ø3W

Notes

• Fifth Terminal: For field installed fifth terminal, order K5T.• Breakers: Rated 22K AIC with QN2200H main installed for U5168 and U5268.• Sub Feed Lugs: #6-350 sub feed lugs provided on 8 circuit interior. Not available on 20 circuit interior.• Main Lug Kit: Main lug feed-through kit K3701 available.• XTL - Two small hub closing plate.• Product numbers with BLG are used in AEP service areas.

U5168-XTL-200-KK U5268-XTL-200-KK

1 2

3 3 3

4 56

54

5 516852685898

K5815Large QN with small frame Q

K5820 Large frame QN with large frame QN

K5830 Small frame Q to small frame Q

Generator Interlock — for use with U5168 and U5268

AIC Rating Amps Siemens Cutler Hammer General Electric Square D

10k150-200 QNR BR (150A only) — —

≤ 125 QP HQP, BR THQL, THQL-GF Homeline

22k150-200 QNRH — — —

≤ 125 QPH — — —

Branch Breaker Chart

Catalog Number Service Amp HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3 4 5

U3989-XL OH/UG 125 C.P. #6-2/0 CB None 33⁄4 11 22 2 1⁄4,1⁄2 — — —

U3491-XL-200 OH/UG 200 C.P. #2-350 CB None 41⁄8 12 29 21⁄2 2 1⁄4 — —

U5844-PXL-200-KK OH/UG 200 C.P. #6-350 CB Horn 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5844-PXL-200-KK-BLG OH/UG 200 C.P. #6-350 CB Horn 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2

Page 16: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

16

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Meter Mains200 Amp | 4 & 7 Terminal | Lever Bypass | Ringless

200 AMPLEVER BYPASSMETER MAINS

200 Amp | Meter Main | Lever Bypass | Ringless

Notes

• Breakers: U5871 is rated 22K AIC with QN2200RH main installed. U5750 is rated 10K AIC with UQFB-3200 main installed.• U5871- Has 8 branch circuits• -BL: Barrel lock• Fifth Terminal: For field installed fifth terminal for U5871, order K5T.• Interlock Kit: For generator auxiliary circuit breaker interlock for U5871, order K5815 for large QN with small frame Q; order K5820 for large frame QN with large frame QN.

Catalog Number TerminalsBreakerAmps

Service HubConnectorsCU/AL - Line

Dimensions Knockouts

D" W" H" 1 2 3 4 5 6

U5871-XL-200 4 200 OH/UG C.P. #6-350 41⁄2 141⁄8 32 3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2

U5750-RXL-200-BL 7 200 OH/UG C.P. #6-350 53⁄4 173⁄8 34 4 3 1 1⁄4 — —

1

2 2

2 34

U5750-RXL-200-BL

57501 2

3 3 3

4 56

5

45

U5871-XL-200

5871

Page 17: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

17

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

320 AMPLEVER BYPASSMETER MAINS

Lever Bypass Meter Mains320 Amp | 4 Terminal | Ringless | 120/240 VAC

Catalog Number HubConnectors CU/AL - Line

BreakerAmps

Branch Circuits

Dimensions Knockouts

D" W" H" 1 2 3 4 5 6

U5059-X-K3L C.P. (1) #4-600 or (2) 1/0-250 Provision N/A 47⁄8 15 42 3 1⁄4,1⁄2 1⁄4 — — —

U5059-X-2/200-K3L C.P. (1) #4-600 or (2) 1/0-250 200 N/A 47⁄8 15 42 3 1⁄4,1⁄2 1⁄4 — — —

U5890-X-2/200-BL* C.P. 3⁄8" x 16 Studs 200 N/A 6 241⁄2 35 4 21⁄2 1⁄4 — — —

U5890-X-2/200-BLG C.P. 3⁄8" x 16 Studs 200 N/A 6 241⁄2 35 4 21⁄2 1⁄4 — — —

U5891-X-2/200-MLK-BL* C.P. 3⁄8" x 16 Studs 200 12 6 291⁄2 35 4 21⁄2 1 1⁄2,3⁄4 1⁄4 —

U4835-X-2/200-BL C.P. 3⁄8" x 16 Studs 200 N/A 53⁄4 247⁄8 30 4 3 1⁄2 — — —

320 Amp | 4 Terminal | Meter Mains | Lever Bypass | Ringless | OH/UG

Notes

• AIC Rating: 22K AIC standard.• Breakers: For U5059 main breakers, order UQFPH-100, -150, or -200. For replacement main breaker in U4835 order

Milbank UQFBH series• -MLK: Main Lug feed-through kit K3701 factory installed.• Fifth Terminal: For field mounted fifth terminal order catalog number K3865.• Connectors: Supplied with 3⁄8" x 16 hex head nuts with Belleville washers. For connector kits, order as extra K1540 (single

600 kcmil). For twin lug connectors, order as extra K1350 (twin 350 kcmil). The extra stud on line side is a wire stop.• Product numbers with BLG are used in AEP service areas (Suffix -BLG is barrel lock with gaurd.)* Barrel lock (suffix -BL)• For replacement main breaker in U5890 order Siemens QN series QN2200H.• For replacement main breaker in U5891, order QN2200H (for left breaker) and a QN2200RH (for right breaker).

U5890-X-2/200-BL(shown with lugs installed)

U5059-X-2/200 U5891-X-2/200-MLK-BL U4835-X-2/200-BL

1

2

2

3

2

22

2

5

3

3 3

4

4 4

1

2

258905891 4835

1

1 1 123

1 1

5059 1

2 2

2

3

2

2

1 2

3 3 3

4 56

54

5 5168

Page 18: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

18

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Meter Mains400 Amp | 4 & 5 Terminal | Ringless

400 AMPMETER MAINS

U6227-X-400-K3L U6230-X-400-K7

Catalog Number Terminals HubConnectors CU/AL Dimensions Knockouts

Line D” W” H” 1 2 3 4

U6227-X-400-K3L 4 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4

U6228-X-400-K3L 4 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4

U6227-X-400-K3L-5T6 5 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4

U6227-X-400-K3L-5T9 5 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4

U6228-X-400-K3L-5T6 5 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4

U6228-X-400-K3L-5T9 5 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4

400 Amp Meter Main | 4 & 5 Terminal | 1Ø3W | OH/UG | 240 VAC

Catalog Number HubConnectors CU/AL Dimensions Knockouts

Line D” W” H” 1 2 3 4

U6229-X-400-K7L C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4

U6230-X-400-K7L C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4

400 Amp Meter Main | 7 Terminal | 3Ø4W | OH/UG | 480 VAC

Specifications

• Side Buss Units: U6230• AIC Rating: 22K AIC at 240V; and 10K AIC at 480V.• 300 Amp breaker: Can be installed from the factory (upon request).

Specifications

• Side Buss Unit: U6228• AIC Rating : 22K AIC at 240V• 300 Amp breaker: Can be installed from the factory (upon request)

1 2 2 2

34

1 6227622862296230

Page 19: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

19

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Meter Mains400 Amp | 7 Terminal | Ringless

Catalog Number HubConnectors CU/AL Dimensions Knockouts

Line D” W” H” 1 2 3 4

U6115-X-2/200-K7L C.P. #4-600kcmil or (2) 1/0 - 250 7 341⁄4 34 1⁄2, 3⁄4 1⁄2, 3⁄4 1⁄2, 3⁄4 1⁄2, 3⁄4

400 Amp Meter Main with Breakers | 7 Terminal | 3Ø4W | Ringless | 480 VAC

Specifications

• U6115-X-2/200-K7L comes with (2) 200A 3Ø breakers

61151 1 2 2 2

34U6115-X-2/200-K7L

400 AMPMETER MAINS

Page 20: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

20

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Cold Sequence Meter Mains200-400 Amp | 4, 5 & 7 Terminal | Ringless

COLDSEQUENCE

METER MAINS

200 Amp Circuit Breaker Disconnect Ahead Of Meter Socket | Lever Bypass

400 Amp (320 Amp Continuous) Circuit Breaker Disconnect Ahead Of Meter Socket | Lever Bypass

Notes

• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.

Catalog Number Terminals Service HubConnectors

CU/AL - LoadPhase

Dimensions Knockouts

D" W" H" 1 2 3 4

U5764-X-200-CB 4 OH/UG C.P. #6-350 1Ø3W 427⁄32 13 43 4 21⁄2 1⁄4 —

U5784-O-200-CB 4 UG Blank #6-350 1Ø3W or 3Ø3W 427⁄32 26 28 4 21⁄2 1⁄4 —

U5765-X-200-CB 5 OH/UG C.P. #6-350 1Ø3W or 3Ø3W 427⁄32 13 43 4 21⁄2 1 1⁄2 , 3⁄4

U5767-X-200-CB 7 OH/UG C.P. #6-350 3Ø4W 427⁄32 13 43 4 21⁄2 1 1⁄2 , 3⁄4

U5787-O-200-CB 7 UG Blank #6-350 3Ø4W 6 26 28 4 21⁄2 1 1⁄2 , 3⁄4

Catalog Number Terminals Service HubConnectors

CU/AL - LoadPhase

Dimensions Knockouts

D" W" H" 1 2 3 4

U5797-O-400-CB 4 UG Blank 3/0-500 1Ø3W or 3Ø3W 6 26 36 4 21⁄2 1 1⁄2 , 3⁄4

U5796-X-400-CB 7 OH/UG C.P. 3/0-500 3Ø4W 6 13 56 4 21⁄2 1⁄4 —

U5799-O-400-CB 7 UG Blank 3/0-500 3Ø4W 6 26 36 4 21⁄2 1 1⁄2 , 3⁄4

U5767-X-200-CB U5787-O-200-CB

1

1 1 123

1

57645765

5767

1

23 344

2 2 21 1

1 1

57845787

1

12 234

1

5796

57975799

1

12 2 2 2343

1

1 1

Page 21: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

21

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

150 AMPMULTI-

POSITION

Multi-Position Sockets150 Amp | 4 Terminal | Ringless | 300 VAC

Catalog Number Positions Service HubConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2 3 4 5

U1232-RRL-KK-K1 2 OH/UG H.O. #6-350 #6-350 51⁄8 261⁄2 14 3 21⁄2 1 1⁄2 1⁄4

U1233-RRL-KK-K1 3 OH/UG H.O. #6-350 #6-350 51⁄8 343⁄4 14 3 21⁄2 1 1⁄2 1⁄4

U1234-RXL-KK-K1 4 OH/UG C.P. #6-350 #6-350 51⁄8 427⁄8 16 3 21⁄2 1 1⁄2 1⁄4

150 Amp per Position | 4 Terminal | Multi-Position | Ringless | Horn Bypass

Notes

• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page. For the U1254-6 two hub openings are supplied and the extra opening is closed with a closing plate as standard.• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T (9 o’clock position).

12 4

4 4

53

2 2 2 2

2 2

12 234 5 4

2 22

U1232-RRL-KK-K11232

123312 2 3 25 2

22222

4 4 4 411234

Page 22: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

22

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Multi-Position Sockets200 Amp | 4 Terminal | Ringless | 300 VAC

200 AMPMULTI-

POSITION

200 Amp per Position | 4 Terminal | Multi-Position | Ringless | Horn Bypass

Notes

• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page. For the U1254-6 two hub openings are supplied and the extra opening is closed with a closing plate as standard.• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T (9 o’clock position).• Product numbers with BLG are used in AEP service areas.

Catalog Number Positions Service HubConnectors CU/AL Dimensions

Line Load D" W" H"

U1252-RRL-KK-K1-SLVG 2 OH/UG H.O. #6-350 #6-350 51⁄8 261⁄2 14

U1252-RRL-KK-K1-BLG-SLVG 2 OH/UG H.O. #6-350 #6-350 51⁄8 261⁄2 14

U1253-RRL-KK-K1-SLVG 3 OH/UG H.O. #6-350 #6-350 51⁄8 343⁄4 14

U1253-RRL-KK-K1-BLG-SLVG 3 OH/UG H.O. #6-350 #6-350 51⁄8 343⁄4 14

U1254-RXL-KK-K1-SLVG 4 OH/UG C.P. #6-350 #6-350 51⁄8 427⁄8 16

U1254-RXL-KK-K1-BLG-SLVG 4 OH/UG H.O. #6-350 #6-350 51⁄8 427⁄8 16

U1255-RXL-KK-K1-SLVG 5 OH/UG C.P. #6-350 #6-350 51⁄8 541⁄2 16

U1255-RXL-KK-K1-BLG-SLVG 5 OH/UG H.O. #6-350 #6-350 51⁄8 541⁄2 16

U1256-RXL-KK-K1-SLVG 6 OH/UG C.P. #6-350 #6-350 51⁄8 631⁄16 18

U1256-RXL-KK-K1-BLG-SLVG 6 OH/UG H.O. #6-350 #6-350 51⁄8 631⁄16 18

U1252-RRL-KK-K1-SLVG

Page 23: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

23

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Multi-Position SocketsKnockout information

KNOCKOUT INFORMATION

Knockouts

1 2 3 4 5

3 21⁄2 1 1⁄2 1⁄4

1222

2 2 2 2

2 2 2

2 2 2

134 45 4 4441 12 2 2 2 2

2 22222

34 4 4 45 4

12 4

4 4

53

2 2 2 2

2 2

12 234 5 4

2 22

1252

125312 2 3 25 2

22222

4 4 4 411254

1255 1256

4

Page 24: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

24

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

200 AMPLEVER BYPASS

MULTI-POSITION

Lever Bypass Multi-Position Sockets200 Amp | 5 Terminal | Ringless | 600 VAC

Catalog Number Positions Service HubConnectors CU/AL

BypassDimensions Knockouts

Line Load D" W" H" 1 2 3

U2872-XT 2 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2

U2873-XT 3 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 423⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2

U2874-XT 4 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 521⁄4 251⁄4 4 21⁄2 1⁄4,1⁄2

U2875-XT 5 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 625⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2

U2876-XT 6 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 723⁄8 311⁄4 4 21⁄2 1⁄4,1⁄2

200 Amp per Position | 5 Terminal | Multi-Position | Ringless

Notes

• Hubs: Units supplied with two closing plates. To order hubs as extra, refer to the hub suffix chart on the accessories page.• Connector Kits: For line side connector kits, order as extra K1539 (350 kcmil), K1540 (600 kcmil), twin K1350 (350 kcmil), twin K1541 (600 kcmil). Line connectors can be reversed to change from “OH” to “UG” service. For line side connector lug kits, order as extra from chart on the accessories page.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.

2 2 2 2

2 2 21 1 3 2

2

2

2 231 1

2 2

2872

2873 2874

U2873-XT

2 2

21 1 3 22

2 2

2 2 2 2 2

2 2 1 1 3 2 2 2

2 2 2

1 1 3

2 2 2 2 2

2 2 2 2 2 22875 2876

Page 25: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

25

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Lever Bypass Multi-Position Sockets200 Amp | 7 Terminal | Ringless | 600 VAC 3 phase

200 AMPLEVER BYPASS

MULTI-POSITION

200 Amp per Position | 7 Terminal | Multi-Position | Lever Bypass | Ringless

Notes

• Hubs: Units supplied with two closing plates. To order hubs as extra, refer to the hub suffix chart on the accessories page.• Connector Kits: For line side connector kits, order as extra K3082 (350 kcmil), K3441 (600 kcmil), twin K3442 (350 kcmil), twin K3083 (600 kcmil). Line connectors can be reversed to change from “OH” to “UG” service.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.

Catalog Number Positions Service HubConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2 3

U2732-XT 2 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2

U2733-XT 3 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 423⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2

U2734-XT 4 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 521⁄4 251⁄4 4 21⁄2 1⁄4,1⁄2

U2735-XT 5 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 625⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2

U2736-XT 6 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 723⁄8 311⁄4 4 21⁄2 1⁄4,1⁄2

2 2 2 2

2 2 21 1 3 2

2

2

2 231 1

2 2

U2732-XT

2732

2733 2734

2 2

21 1 3 22

2 2

2 2 2 2 2

2 2 1 1 3 2 2 2

2 2 2

1 1 3

2 2 2 2 2

2 2 2 2 2 22735 2736

Page 26: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

26

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

125 & 200 AMPMULTI-

POSITIONMETER MAINS

Multi-Position Meter Mains125-200 Amp/Position | 4 Terminal | Ringless | 120/240 VAC

10K AIC

Catalog NumberAmps Per Position

Positions Main Bus Rating Line Connector SizeDimensions

D" W" H"

U2852-X 125 2 200 Amp 3⁄8" x 16 Stud* 513⁄16 18 25

U2853-X 125 3 200 Amp 3⁄8" x 16 Stud* 513⁄16 18 37

U2854-X 125 4 400 Amp 3⁄8" x 16 Stud* 47⁄8 31 25

U2855-X 125 5 400 Amp 3⁄8" x 16 Stud* 47⁄8 31 37

U2856-X 125 6 400 Amp 3⁄8" x 16 Stud* 47⁄8 31 37

Catalog NumberAmps Per Position

Positions Main Bus Rating Line Connector SizeDimensions

D" W" H"

U2862-X 200 2 250 Amp 3⁄8" x 16 Stud* 513⁄16 21 29

U2863-X 200 3 300 Amp 3⁄8" x 16 Stud* 513⁄16 21 41

U2864-X 200 4 400 Amp 3⁄8" x 16 Stud* 47⁄8 36 29

U2865-X 200 5 600 Amp 3⁄8" x 16 Stud* 47⁄8 36 41

U2866-X 200 6 600 Amp 3⁄8" x 16 Stud* 47⁄8 36 41

Size Suffix Kit Number Compatible With Wire Range

Single-K1 K1539 U2852-56, U2862-66 #6-350

-K3 K1540 U2854-56, U2864-66 #4-600

Twin-K2 K1350 U2854-56, U2863-66 #6-350

-K4 K1541 U2864-66 #2-600

Manufacturer 150-200 Amps 125 Amps or Less

Milbank WBJ —

Cutler Hammer BR, BJ Quicklag P, BR, HQP

Siemens QNR QP

Siemens/Murray MD MP

G.E. Q Line Q Line

Square D — Homeline

125 Amp per Position | Multi-Position Sockets | 10K AIC | Ringless

200 Amp per Position | Multi-Position Sockets | 10K AIC | Ringless

Connector Kits Breaker Chart

Notes

• Connectors: For line wire connector kits, order separately.• Fifth Terminal: For field mounted fifth terminal, order catalog number K2381. Order one per meter position.• Breakers: Units have provision for one double pole main per meter position. Breakers not included.• Short Circuit Current Rating: 10K AIC. However, this rating is limited to the lowest interrupting capacity of any circuit breaker installed. Watthour meter not included in short circuit current rating.• Knockouts: See next page for drawings and knockout configurations.* To add lugs, see the Connector Kits chart.

U2866-XU2854-X

(Order circuit breakers separately)

Page 27: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

27

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Multi-Position Meter MainsKnockout Information

125/200 AMPMULTI-

POSITIONMETER MAINS

Catalog NumberKnockouts

1 2 3

U2852-X 3 11⁄4 1⁄4,1⁄2

U2853-X 3 11⁄4 1⁄4,1⁄2

U2854-X 3 11⁄4 1⁄4,1⁄2

U2855-X 3 11⁄4 1⁄4,1⁄2

U2856-X 3 11⁄4 1⁄4,1⁄2

U2862-X 3 2 1⁄4,1⁄2

U2863-X 3 2 1⁄4,1⁄2

U2864-X 3 2 1⁄4,1⁄2

U2865-X 3 2 1⁄4,1⁄2

U2866-X 3 2 1⁄4,1⁄2

1 1 23 2 22 2 2

12

322 222

12

322 222

213

22 222

13222

1

2

2223

2

28522862

28532863

2854

2864

2855 2856

1 1 23 2 22 2 2 1 1 23 2 22 2 22865 2866

Page 28: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

28

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

125-200 AMPMULTI-

POSITIONMETER MAINS

Multi-Position Meter Mains125-200 Amp | 4 Terminal | Ringless | 120/240 VAC | 22K AIC

Catalog Number Amps Positions Service HubConnectors CU/AL

BypassDimensions Weight

(lbs.)Line D" W" H"

U5902-X-KK-BLG 125 2 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 261⁄2 30 58

U5903-X-KK-BLG 125 3 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 345⁄9 30 88

U5904-X-KK-BLG 125 4 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 424⁄5 30 107

U5905-X-KK-BLG 125 5 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 511⁄20 30 128

U5906-X-KK-BLG 125 6 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 593⁄10 30 146

Catalog Number Amps Positions Service HubConnectors CU/AL

BypassDimensions Weight

(lbs.)Line D" W" H"

U5882-X-KK-BLG 200 2 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 261⁄2 30 58

U5883-X-KK-BLG 200 3 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 345⁄9 30 88

U5884-X-KK-BLG 200 4 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 424⁄5 30 107

U5885-X-KK-BLG 200 5 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 511⁄20 30 128

U5886-X-KK-BLG 200 6 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 593⁄10 30 146

125 Amp per Position | 4 Terminal | Multi-Position Meter Main | Ringless

200 Amp per Position | 4 Terminal | Multi Position Meter Main | Ringless

Notes

• Knockouts: See drawings on the next page.• Optional: Factory installed breakers are available - consult factory.• AIC Rating: All models are rated 22K AIC when used with approved breakers rated at 22K.• Hub: Units supplied with one (1) closing plate. Order hubs separately, see accesory page.• Fifth Terminal: For field installed fifth terminal, order K5T.• Connectors: Socket is supplied with 3⁄8" - 16 hex head nuts with Belleville washers. For connector lug kits, order as extra

from chart on the accessories page. Separate lug kits are required for line and load.

U5882-X-KK-BLG U5884-X-KK-BLG

Rating kAIC

Circuit Breaker125A

10

SIEMENS: QPCUTLER-HAMMER: BR, HQP, QHP,QPGF

SQUARE D: HOMELINE.G.E.: (50AMP.MAX.) THQL, THQL-GF

22 SIEMENS: QPH

150-200 AMP

10 SIEMENS: QN

22 SIEMENS: QNH

Page 29: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

29

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Multi-Position Meter MainsDimensional Information

125/200 AMPMULTI-

POSITIONMETER MAINS

Knockouts

1 2 3 4 5

3 21⁄2 1 7⁄8 1⁄4

1 34 45 22

2 2

30

26.5

5.13

12 3 22 1

30

5.13

34.6

1 12 2 2 2 23

30

51.1

5.13

1 12 2 2 2 2 23

30

59.3

5.13

1 3 1 222 2

30

42.8

5.13

58825902

58835903

58845904

58855905

58865906

Page 30: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

30

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Catalog Number Terminals Type Hub Meter Form Connectors CUDimensions Knockouts

D" W" H" 1 2 3 4

UC1299-RL 6 Ringless H.O. 4S #14-#4 MAX 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4

UC7235-RL 8 Ringless H.O. 5S #14-#4 MAX 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4

UC7237-XL 13 Ringless C.P. 6, 8, 9 #14-#4 MAX 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4

Catalog Number Terminals Type Hub Meter Form Connectors CUDimensions Knockouts

D" W" H" 1 2 3 4

UC1300-RL 6 Ring Type H.O. 4S #14-#4 MAX 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4

Transformer Rated20 Amp | Plunger Bypass | Ringless & Ring Type

1 Piece Cover | Overhead / Underground | Ringless

1 Piece Cover | Overhead / Underground | Ring Type

UC7235

2

1

4

33

2

130072357237

20 AMPTRANSFORMER

RATED

Notes

• Hubs: For proper hub selection see the hub suffix chart on the accessory page.

Page 31: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

31

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

20 AMPTRANSFORMER

RATED

Transformer Rated20 Amp | Test Switch Provision

Catalog Number Terminals Hub Meter Form Connectors CU BypassDimensions Knockouts

D" W" H" 1 2

UC7478-RL 6 H.O. 4S #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2

UC7444-RL 8 H.O. 5S #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2

UC7445-RL 13 H.O. 6, 8, 9 #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2

UC7445-RL-641* 13 H.O. 6, 8, 9 #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2

UC7445-WL 13 1 in 6, 8, 9 #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2

RinglessCatalog Number

Ring TypeCatalog Number

Terminals Meter Form Hub Connectors CUDimensions Knockouts

D" W" H" 1 2

UC7532-RL UC7636-RL 6 4S H.O. #14 - #4 Max 41⁄8 12 20 11⁄4 1⁄4, 1⁄2

UC7448-RL UC7460-RL 8 5S H.O. #14 - #4 Max 41⁄8 12 20 11⁄4 1⁄4, 1⁄2

UC7449-RL UC7461-RL 13 6, 8, 9 H.O. #14 - #4 Max 41⁄8 12 20 11⁄4 1⁄4, 1⁄2

1 Piece Cover | Ringless | Overhead / Underground | with test switch provision

2 Piece Cover | Ringless | Overhead / Underground | with test switch provision

Notes

• Hubs: For proper hub selection see the hub suffix chart on the accessory page.• Sealing Rings: Ring type units are supplied with one MR-2, snap type, sealing ring.• Pre-wiring: Factory pre-wiring available.• Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are preferred, change catalog prefix to “S” (i.e, UC7445-XL becomes S7445-XL). The “S” prefix also designates non-U/L.

*Pre-wired per Lebanon specifications

1 1

1 211744474457478

1 1

1 211746074617636

UC7449-XL UC7532-RLUC7478-RL

744874497532

1 1

1 211

Page 32: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

32

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Lever Bypass Transformer Rated80 Amp | 6, 8 & 13 Terminal

80 AMPTRANSFORMER

RATED

80 Amp | Ringless | Transformer Rated | Lever Bypass | No Test Switch Provision

Notes

• Hubs: For proper hub selection see the hub suffix chart on the accessory page.• Bypass: Lever operates current bypass device and also supplies clamping action on current meter spades.• Connectors: Units are supplied with mechanical type connectors (#4 max).

Catalog Number

Terminals Service Hub Meter Form Connectors CUDimensions Knockouts

D" W" H" 1 2 3 4 5

U4490-XL 6 OH/UG C.P. 4S #14 - #4 Max 47⁄8 10 181⁄2 3 11⁄2 1⁄2,3⁄4 3⁄4 1⁄4

U4492-XL 8 OH/UG C.P. 5S #14 - #4 Max 47⁄8 10 181⁄2 3 11⁄2 1⁄2,3⁄4 3⁄4 1⁄4

U4493-XL 13 OH/UG C.P. 6, 8, 9 #14 - #4 Max 47⁄8 10 181⁄2 3 11⁄2 1⁄2,3⁄4 3⁄4 1⁄4

U4490-XL

1 2

2 23

4

5

44904492

Page 33: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

33

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

TESTSWITCHES

Test Switches4, 7 & 10 Pole

7 1/2"

3 1/2"

3 1/2"

9 1/2"

KeyP Potential Switch

C+ Line side current switch with short circuit assembly

C Load side current switch with test jack assembly

N Neutral bar (no switch)

Pn Neutral Potential Switch

X Unused Position on base

Insulating barrier, isolates both sides of switch

Catalog Number 7-Pole on a 10-Pole Base

TS07-0049 P X P X Pn X C+ C C C+

TS07-0018 P X P X Pn X C+ C C+ C

TS07-0059 X P C+ C P C C+ Pn X X

TS07-0022 P X P X Pn X C C+ C C+

Catalog Number 10-Pole

TS10-0109 P P P Pn C+ C C+ C C+ C

TS10-0110 P C+ C P C+ C P C+ C Pn

TS10-0111 P P P Pn C C+ C C+ C C+

TS10-0112 C+ C C+ C C+ C P P P Pn

Catalog Number 7-Pole

TS07-0105 P P Pn C+ C C+ C

TS07-0106 P C+ C P C+ C Pn

TS07-0107 P P Pn C C+ C C+

TS07-0108 C+ C C+ C P P Pn

CatalogNumber 4-Pole

TS04-0101 X P Pn X C+ C X

TS04-0102 X P C+ C X Pn X

TS04-0103 X P Pn X C C+ X

TS04-0104 X C+ C X P Pn X

Notes

• 4-pole switches are also available on 10-pole bases. Contact Milbank for appropriate catalog numbers.

Notes

• 4-pole switches are also available on 10-pole bases. Contact Milbank for appropriate catalog numbers.

Page 34: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

34

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Test Switch WorksheetElectronic version available at milbankworks.com

KeyP Potential Switch

C+ Line side current switch with short circuit assembly

C Load side current switch with test jack assembly

N Neutral bar (no switch)

Pn Neutral Potential Switch

X Unused Position on base

Insulating barrier (one side)

Insulating barrier (two sides)

4

7

10

Other ____

Yes | Clear ___ Black ___

No

7-Pole

10-Pole

Number of Poles Test Switch Cover (only available for 10-pole bases)

Base Size

q qq qq

qqq

Engineering Information: ______________________________________________________________________________

______________________________________________________________________________________________________

_______________________________________________________________________________________

Customer Name: _________________________________________________________________

Email: ___________________________________________________________________________

_________________________________________________________________________________

Phone: _________________________________________________________________________

Custom Pole Arrangements: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C+ line side, current switch/shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply.

TEST SWITCH BASEThe base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track-resistant, flame-retardant and has low water absorption qualities. Bases are available in two standard sizes following NEMA mounting classifications.

Handle Color KeyBK Black P Purple Y Yellow GN Green

R Red BL Blue W White BKS Black Stripe

BR Brown GR Grey O Orange WS White Stripe

1 2 3 4 5 6 7 8 9 10

Pole Position Chart

Feature 1 2 3 4 5 6 7 8 9 1045° Angle Stops

Ganged Handles (C)

Bussing

Colored Handles

Special Features

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

TEST SWITCHWORKSHEET

Page 35: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

35Current Transformer CabinetPanel Enclosure | Type 3R

CURRENT TRANSFORMER

CABINET

Outdoor Transformer Cabinets | NEMA 3R

Notes

• Features: Supplied with solid back board when noted, three point locking handle, lift off hinges with stainless steel pins and padlock provisions.

• U5990-O: is 3Ø with a 50K RMS rating, and has a wire range of #4-600 kcmil• Units with U Prefix are UL listed.

Catalog NumberDimensions Gauge of

SteelBoard Size CT Mounting

Provisions# of Doors Latching Type

D" W" H" W" H"

U4408-O 14 40 40 12 40 40 Wood 2 3 point latch

U4410-O 12 32 24 14 28 20 Wood 1 Flip latch

S4019-O 10 32 24 14 24 16 Wood 2 3 point latch

S4020-O 10 36 32 14 28 24 Wood 2 3 point latch

S4399-O 10 24 18 14 16 10 Wood 2 3 point latch

S4400-O 10 44 30 14 36 22 Wood 2 3 point latch

304410-CTC3R 10 44 30 12 — — None 2 Hasp

243210-CTC3R 10 32 24 14 — — None 2 Hasp

363612-LC3R-SP-WB 12 36 36 14 33 33 Rails 1 Wing handle

484812-CT3R-WB 12 48 48 14 44 44 Rails 2 3 point latch

U5990-O 10 36 36 12 CT mounting rack included 2 3 point handle

304410-CTC3R U5990-O

Page 36: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

36 Multi-Position Tap BoxThree Phase | Aluminum Construction | Wall or Pad Mountable

Catalog Number PhasePosition

LugsMaximumWire Size

MaximumAmperage

Dimensions

D" W" H"

UAP6094-O 3 16 500 kcmil 3000 Amps 16 255⁄8 43

UAP6095-O 3 22 500 kcmil 4000 Amps 16 323⁄8 43

UAP6096-O 3 14 750 kcmil 3300 Amps 16 2515⁄16 51

Features• Painted Aluminum Construction: Enclosure

shells are constructed with lightweight aluminum, making wall-mount installations easier. Powder-coat paint finish helps prevent corrosion.

• Capable of Wall or Pad Mounting: Units feature a removable bottom, allowing an easy conversion from a wall-mount to a pad-mount.

• Smaller Footprint: The UAP6094 model has a more compact footprint compared with the leading competitor.

• Multi-port ground lugs• Optional Pentabolt Secured Handle

available (see pics below): Enclosure handle can be included with an optional pentabolt locking mechanism (see photos below) for enhanced protection.

Common Applications

Strip Malls Housing DevelopmentsApartment Buildings

Stainless steel pad mount spacing brackets included

MULTI-POSITIONTAP BOX

Page 37: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

37Multi-Position Tap BoxLine Drawings

6094

6096

25 5/8" O.D.

43"

3"

5 1/8"

7"

16" I.D.

32 3/8" O.D.

43"

3"

5 1/8"

7"

16" I.D.

25 15/16" O.D.

51"

3"

5 1/8"

7"

16" I.D.

LINE DRAWINGS

Page 38: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

38

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

200 AMPMETER MAIN WITH

LOAD CENTER

PEDESTAL

Meter Main w/ Load Center Pedestal 100-200 Amp | 4 Terminal | Ringless | 120/240 VAC

Catalog NumberBreakerAmps

Service PowerheadsBranchCircuits

BypassConnectors CU/AL Knockouts

Line Load 1 2 3

U5136-O Provision UG Single 4 Horn #6-350 CB 2 1⁄2,3⁄4 1⁄4

U5136-O-100S 100 UG Single 4 Horn #6-350 CB 2 1⁄2,3⁄4 1⁄4

U5136-O-200S 200 UG Single 4 Horn #6-350 CB 2 1⁄2,3⁄4 1⁄4

U5137-O-200S 200 UG Double 4 Horn #6-350 CB 2 1⁄2,3⁄4 1⁄4

Catalog NumberBreakerAmps

Service PowerheadsBranchCircuits

BypassConnectors CU/AL Knockouts

Line Load 1 2 3

U6220-O-100-KK-10GR 100 UG Single 10 Horn #6-350 #6-350 2 1⁄2,3⁄4 1⁄4

U6220-O-200-KK-10GR 200 UG Single 8 Horn #6-350 #6-350 2 1⁄2,3⁄4 1⁄4

100-200 Amps | 4 Terminal | Meter Main Pedestal | Ringless

100-200 Amps | 4 Terminal | Meter Main Pedestal | Ringless

Notes

• Parallel to Series Conversion: For field converting from parallel wired to series wired order K5194.• Fifth Terminal: For field installed fifth terminal, order K5T.• Stabilizer Foot: For field installed stabilizer foot, order K5415.• Penta Bolt Locking: For field installed pedestal fronts penta bolt locking, order K5039.• Receptacles: Consult factory for installed receptacle assemblies.• Short Circuit Current Rating: 22K AIC. However, this rating is limited to the lowest interrupting capacity of any circuit breaker installed. Watthour meter not included in short circuit current rating.• Receptacle Bridge is ordered separately on part# K5400-BRIDGE-2POS.• Contact factory for receptacle configurations available.• Pedestals with -10GR suffix include a 20 amp GFI receptacle.

U5136-O-200S

24”

27.5”

50”

80”

Grade Level

1

1

2 2

3 3

1

1

9.875”4.13”

16.07”

51365137

U6220-O-20

Rating kAIC

Large Frame Main Breaker

Small Frame Branch Breakers

10 UQFP-M

SIEMENS: QP, QTCUTLER-HAMMER: QP, BD, BR;

G.E.: TQ, THQ, THQLSQUARE D: HOM115, HOM2100

22 UQFPH-M QPH

AIC Rating Amps Siemens Cutler Hammer General Electric Square D

10k150-200 QNR BR (150A only) — —

≤ 125 QP HQP, BR THQL, THQL-GF Homeline

22k150-200 QNRH — — —

≤ 125 QPH — — —

Breaker Chart U5136 & U5137

Breaker Chart U6220

Page 39: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

39

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

DEVICE PLATES

Device PlatesU5136 & U5137

K5935-41 K5935-10GR K5935-11GR

K5935-36GR K5935-54 K5935-2/1450

K5400-BRIDGE-2POS

Page 40: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

40

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Temporary Power Units125 Amp | 4 Terminal | Ringless | 120/240 VAC

TEMPORARYPOWER

125 Amps | 4 Terminal | Temporary Power Units | Ringless | 1Ø3W

Notes

• Interior: Six circuit plated copper interior accepts standard plug-in type circuit breakers.• Receptacle Bridge: Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates.• Included Parts: U4908 and U5101 come supplied with 2-20 amp single pole breakers and 2-20 amp GFCI receptacles installed and pre-wired.

Catalog Number Service HubConnectors CU/AL Dimensions Knockouts

Line Load D" W" H" 1 2 3 4 5

U5101-XL-11GR OH C.P. #6-350 #6-350 53⁄16 87⁄8 25 2 11⁄2 11⁄4 1⁄4 —

U4908-O-11GR UG Blank #6-2/0 #6-2/0 53⁄16 9 2515⁄16 2 11⁄2 11⁄4 1⁄4 —

1

3

4 4

22

3

U4908-O-11GRU5101-XL-11GR

1

3

2

4 4

2 49085101

Page 41: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

41

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

SURFACE MOUNT POWER

OUTLET

Surface Mount Power OutletMillennium Series | Metered & Unmetered | 120/240 VAC

Catalog Number

Metered/Unmetered

ReceptacleConfiguration

Circuit Breaker Configuration

LoopFeed

Connectors -Line

Dimensions Knockouts

D" W" H" 1 2 3

U5000-XL* Unmetered — — Yes (2) 1/0-#12 51⁄2 91⁄8 191⁄4 2 11⁄2 11⁄4

U5000-XL-41 Unmetered A X Yes (2) 1/0-#12 51⁄2 91⁄8 191⁄4 2 11⁄2 11⁄4

U5000-XL-55 Unmetered B Y Yes (2) 1/0-#12 51⁄2 91⁄8 191⁄4 2 11⁄2 11⁄4

U5000-XL-75 Unmetered C Z Yes (2) 1/0-#12 51⁄2 91⁄8 191⁄4 2 11⁄2 11⁄4

U5100-XL* Metered — — No #6-250 51⁄2 91⁄8 25 2 11⁄2 11⁄4

U5100-XL-41 Metered A X No #6-250 51⁄2 91⁄8 25 2 11⁄2 11⁄4

U5100-XL-55 Metered B Y No #6-250 51⁄2 91⁄8 25 2 11⁄2 11⁄4

U5100-XL-75 Metered C Z No #6-250 51⁄2 91⁄8 25 2 11⁄2 11⁄4

125 Amp | Surface Mount Power Outlets | Ring-Type

Receptacle Configurations

Circuit Breaker Configurations

1 22

3 3

5000

U5000-XL-75 U5100-XL-75

1

3 3

22

5100

NOTE

Contact factory for additional configurations not shown here.

A B C

(1) TT30R, (1) 5-20R GFI (1) 14-50R, (1) 5-20R GFI (1) 14-50R, (1) TT30R,(1) 5-20R GFI

X Y Z

(1) 30A, 1P, 120V(1) 20A, 1P, 120V

(1) 50A, 2P, 120/240V(1) 20A, 1P, 120V

(1) 50A, 2P, 120/240V(1) 30A, 1P, 120V(1) 20A, 1P, 120V

* Comes with circuit breaker bridge For easy read meter see the accessory pages for CL200 analog or CL200-D digital meter.

Page 42: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

42

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Power Outlet PedestalsMillennium Series | Metered & Unmetered | 120/240 VAC

POWER OUTLETPEDESTALS

125 Amp | Power Outlet Pedestals | Direct Burial | Ring-Type

Catalog NumberDouble Head

Catalog NumberMetered/

UnmeteredReceptacle

ConfigurationCircuit Breaker Configuration

Dimensions Knockout

D" W" H" 1

U5200-XL* U5220-XL Unmetered — — 59⁄16 91⁄8 641⁄2 11⁄4

U5200-XL-41 U5220-XL-41 Unmetered A X 59⁄16 91⁄8 641⁄2 11⁄4

U5200-XL-55 U5220-XL-55 Unmetered B Y 59⁄16 91⁄8 641⁄2 11⁄4

U5200-XL-75 U5220-XL-75 Unmetered C Z 59⁄16 91⁄8 641⁄2 11⁄4

U5300-O* U5320-O Metered — — 59⁄16 91⁄8 701⁄4 11⁄4

U5300-O-41 U5320-O-41 Metered A X 59⁄16 91⁄8 701⁄4 11⁄4

U5300-O-55 U5320-O-55 Metered B Y 59⁄16 91⁄8 701⁄4 11⁄4

U5300-O-75 U5320-O-75 Metered C Z 59⁄16 91⁄8 701⁄4 11⁄4

1 2 2

52005220

U5200-XL-75 U5300-O-75

1 2 2

53005320

Receptacle Configurations

Circuit Breaker Configurations

NOTE

Contact factory for additional configurations not shown here.

Pad mount is available - contact factory for information.

A B C

(1) TT30R, (1) 5-20R GFI

(1) 14-50R, (1) 5-20R GFI

(1) 14-50R, (1) TT30R, (1) 5-20R GFI

X Y Z

(1) 30A, 1P, 120V(1) 20A, 1P, 120V

(1) 50A, 2P, 120/240V(1) 20A, 1P, 120V

(1) 50A, 2P, 120/240V(1) 30A, 1P, 120V(1) 20A, 1P, 120V

*Circuit Breaker Bridge included

Page 43: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

43

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

CIRCUITBREAKERS

Circuit BreakersUQFP Plug-In & UQFB Bolt-On Series | 120/240 VAC

UQFPUQFPH

UQFP-MUQFPH-M

200 Amp Frame | Plug-In | 10,000 AIC & 22,000 AIC | Two-Pole - Common Trip

200 Amp Frame | Bolt-On | 10,000 AIC & 22,000 AIC | Two-Pole - Common Trip

Amps10K AIC Plug-In

22K AIC Plug-In

10K AICPlug-In

22K AICPlug-In

Wire Range

CU AL

100 UQFP-100 UQFPH-100 UQFP-M-100 UQFPH-M-100 #3-#1 #1-1/0

125 UQFP-125 UQFPH-125 UQFP-M-125 UQFPH-M-125 #3-#1 #1-1/0

150 UQFP-150 UQFPH-150 UQFP-M-150 UQFPH-M-150 1/0-300 2/0-300

175 UQFP-175 UQFPH-175 UQFP-M-175 UQFPH-M-175 1/0-300 2/0-300

200 UQFP-200 UQFPH-200 UQFP-M-200 UQFPH-M-200 1/0-300 2/0-300

Amps10K AICBolt-On

22K AICBolt-On

10K AICBolt-On

22K AICBolt-On

Wire Range

CU AL

100 UQFB-100 UQFBH-100 UQFB-100-X1 UQFBH-M-100 #3-#1 #1-1/0

125 UQFB-125 UQFBH-125 UQFB-125-X1 UQFBH-M-125 #3-#1 #1-1/0

150 UQFB-150 UQFBH-150 UQFB-150-X1 UQFBH-M-150 1/0-300 2/0-300

175 UQFB-175 UQFBH-175 UQFB-175-X1 UQFBH-M-175 1/0-300 2/0-300

200 UQFB-200 UQFBH-200 UQFB-200-X1 UQFBH-M-200 1/0-300 2/0-300

Notes

• UL Listed: For use with 60°C or 75°C wire.• UQFP: For parallel main circuit breaker applications.• UQFP-M: For series main circuit breaker applications Split load tab features allow for feed-through capability.• UQFB: (2) 1/0-300 lugs provided on load and line side (cable-in, cable-out).• UQFB3: Three-pole available. Consult factory.• UQFB-X: (2) 1/0-300 lugs provided on load side and (2) line bar bus connections on line side.• UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed-through capability.

UQFB-X1 UQFBH

Page 44: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

44

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

CIRCUITBREAKERS

Circuit BreakersQP (small frame) and QN (large frame) | 120/240 VAC

QN2200H

Q250WBJ2200

QN2200RH

15–125 Amp BreakerPlug-In Type | 1” Per Pole

Amps Poles10K AIC Plug-In

22K AIC Plug-In

15 Single Q115 Q115H

15 Double Q215 Q215H

20 Single Q120 Q120H

20 Double Q220 Q220H

25 Single Q125 Q125H

25 Double Q225 Q225H

30 Single Q130 Q130H

30 Double Q230 Q230H

35 Single Q135 Q135H

35 Double Q235 Q235H

40 Single Q140 Q140H

40 Double Q240 Q240H

50 Single Q150 Q150H

50 Double Q250 Q250H

60 Single Q160 Q160H

60 Double Q260 Q260H

70 Single Q170 Q170H

70 Double Q270 Q270H

80 Double Q280 Q280H

90 Double Q290 Q290H

100 Double Q2100 Q2100H

125 Double Q2125 Q2125H

• Load connectors supplied with breakers.• UL Listed for use with 60°C or 75°C wire.• Wire sizes shown are lug capacity. Consult NEC Article #310 for specific wire sizes.

Notes

200 Amp Frame | Plug-In | 10,000 AIC & 22,000 AIC | Two-Pole, Common Trip

Amps 10K AIC Plug-In 22K AIC Plug-In Handle LocationWire Range

CU AL

150 QN2150 QN2150H Left facing #4-300 #4-300

200 QN2200 QN2200H Left facing #4-300 #4-300

150 QN2150R QN2150RH Right facing #4-300 #4-300

200 QN2200R QN2200RH Right facing #4-300 #4-300

150 WBJ2150 — Centered #2-300 #2-300

200 WBJ2200 — Centered #2-300 #2-300

Page 45: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

45

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

AccessoriesHubs and Closing Plates

ACCESSORIES

-R

Large hub opening

-WL A7514 -YL A7515 -ZL A7516 -DL A7517 -EL A7518 -XL A7551

1" hub 11⁄4" hub 11⁄2" hub 2" hub 21⁄2" hub Small closing plate

-F A8110 -G A8111 -H A8112 -X A9064 -RRL S8324 -RXL S8324 A7551

3" hub 31⁄2" hub 4" hub Large closing plate Large hub open-ing adapted to

small hub open-ing

Large Hub opening adapted to small

closing plate

-RL

Small hub opening

Notes

• Suffix: Add to catalog number for factory installation of hub.• Packaging: Individually packed units for field installation.• Abbreviations: H.O. (hub opening), C.P. (closing plate).• Hub Mast rated

Page 46: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

46

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

AccessoriesConnector Kits, Closing Kits & Generator Interlock

ACCESSORIES

Connector Kits — For Use with 3⁄8"-16 Stud Type Units Only

Closing Covers

Pole Hanger Kit850 comes with 4 pole hangers

Single Twin

Suffix Part # (3 per set) - 1Ø Suffix Part # (3 per set) - 1Ø

K1 K1539 6-350 K2 K1350 6-350

K3 K1540 4-600 or (2) 1/0-250* K2L K1350L 6-350 (non rotating)

K3L K1540L4-600 or (2) 1/0-250*

(non rotating) K4 K1541 4-600

Suffix Part # (4 per set) - 3Ø Suffix Part # (4 per set) - 3Ø

K5 K3082 6-350 K6 K3442 6-350

K7 K3441 4-600 or (2) 1/0-250* K8 K3083 4-600

Catalog Number

Description of pole hanger brackets

850Two pair (4 pieces)

with mounting hardware

Meter Closing Plate(Ring Type / Ring-

less)

Metal Closing Plate(For Ringless Sock-

ets)

6003 - Grey Plastic CP-21

6116 - Clear Plastic

6002 - Clear Plastic

K8180 (sold in pairs)

Bypass Link

K1047

A-GP

12 oz. spray can of grey paint

M5-144

Do not use with lever bypass sockets

Isolated Neutral Kit

ANSI-61-Grey

Disconnect Sleeve

Note

Consult factory for proper connector kits for studded meter sockets.

*For (2) 1/0-250, conductors must be of same size.

Page 47: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

47

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

AccessoriesFifth Terminals, Tap Connectors & Block Assemblies

ACCESSORIES

K1190 (For factory installed triplex ground, add suffix -TG to catalog number)

Fifth Terminals

Tap Connectors (3 per set)

100 Amp Blocks (single sockets only) 200 Amp Blocks (single sockets only)

5T8K2 - 100-200 Amp“Plug-In”

K5T - 200 Amp (Block with Square Hole)

K3865 - Heavy Duty Jaw Clamping (K3866 without Neutral Wire) K3356

Replaces the load or line side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 100 amp tap location in addition to the #6-350 kcmil load-side connector. K5022 includes safety barrier extensions for applications over 300 VAC. Three lugs per kit.

K4977-INT - Internal Hex

K4977-EXT - External Hex

K5022-INT - Internal Hex (set of 4 w/ barrier) Wire Range #12 - 1/0

BL7474 - Block Assembly

Z904486-AO - Slotted Nut Assembly

Z802965-AC - Neutral without Nut

Z901925-AC - Hex Nut Set Screw

K4527 - Internal Hex Block Assembly (w/ meter support)

K4528 - External Hex Block Assembly (w/ meter support)

Z916265-AO - Internal Hex Slide Nut Assembly

Z916264-AO - External Hex Slide Nut Assembly

Z814898-AC - Neutral without Nut

Triplex Ground

Page 48: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

48

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

COMMERCIALPEDESTALS

Commercial PedestalsAttractive | Easy to Install | Secure | Cost-Effective

Milbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures.

UL-listed as Industrial Control Equipment (File E113855)

Strut and backboard Commercial pedestal

• Type 3R rain resistant, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available)• UL-listed as enclosed industrial control equipment (UL508)• Isolated lockable & sealable utility metering and lug landing sections• Lockable customer section for distribution and control equipment with internal deadfront• Print pocket inside customer section door contains wiring schematics and installation instructions• Most load centers are UL-listed for use with various manufacturers’ circuit breakers• All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws)

Standard Features

Page 49: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

49

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

COMMERCIALPEDESTALS

K3865Fifth terminal kit for use with ringless meter sockets

CP-ABK5/8Anchor bolt kit (includes four 5⁄8 - 13 x 18” anchor bolts

105JFifth terminal kit for use with ring-type meter sockets

CP-PE-HOA-3POSHOA switch for field installation

CP-TC7D 7-day time clock kitCP-TC24H24-hour time clock kitCP-TCWIREMale 4-pin connector and wiring harness for use with time clocks other than above

CP-16PDMNT-CALT 16" pedestal mounting baseCP-24PDMNT-CALT 24” pedestal mounting base (includes mounting hardware)

Commercial PedestalsAttractive | Easy to Install | Secure | Cost-Effective

Accessories

These units are ideal for controlling and metering:• Traffic signals• Street lighting• Power distribution for EV charging stations• Irrigation and sprinkler systems• Cell towers and telephone vaults• Pump stations• Temporary power for fairgrounds, swap meets, outdoor markets,

portable offices, holiday lights, etc.• Outdoor lighting for athletic fields, tennis and basketball courts,

parking lots, landscaping and subdivision entrances, etc.

• Meter sockets: ring type or ringless, up to 400 amp• Main and branch breakers or T fuses• Distribution: copper load centers and panel boards• Clocks, timers and relays• Photoelectric cells and controls• Power receptacles: pin and sleeve, twist lock or straight blade• Contactors: definite purpose, electrical or mechanically held, IEC

and mercury types• Surge protection and lightning arrestors• Reserve inlet generator receptacle with interlocked circuit breakers• Motor starters and relays• Push button controls• Thermostat controls, fans and heating strips• Power blocks and terminal blocks• Steel, aluminum and plywood backboards• Transformers• Interlock devices for circuit breakers• Available in steel, aluminum (raw painted or anodized) or stainless steel

construction with powder-coated finish available in eight standard colors or special-ordered RAL colors

• Available for applications up to 400 amp, 120V, 208V, 240V, 277V, 480V - 1Ø or 3Ø

Applications

Available Factory-Installed Options

Page 50: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

50

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Stocked Pedestals*Optional Fifth Terminal Kit

Main CB Load Center Circuits

Meter Socket Typeamp Spaces

CP3B51115A22 K3865 100 1,2 16 Ringless socket with lever bypassCP3B52119A22 K3865 200 1,2,3,4 24 Ringless socket with lever bypass

COMMERCIALPEDESTALS

Commercial PedestalsMain Load Center Series | Custom Designs Available

Notes

• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.

CP3B “ML” SeriesMain Load Center Series1Ø3 wire 120/240V or 208Y/120VApplication: remote site service for multiple loadsThe Milbank Main Load Center Commercial Pedestals are designed to handle the vast majority of all requirements in a standard, stocked configuration. • All units feature a load center with a plug-on, back-fed main breaker. • Load center has 16 positions for the 100 amp pedestals and 24 circuits for the 200 amp pedestals. • Both sizes include sub-feed lugs to allow feeding an external panel.

If your application requires turning loads on based on “dusk-to-dawn” requirements, be sure to see the Milbank Switched Load Center Commercial Pedestal products on the following page.

Typical Applications

Remote site service for multiple loads.

CP3B11115A22

Features

These units include everything required for remote site service:

• NEMA 3R construction.• Expandable: load centers allow for future expansion without costly

modifications.• All units feature 200 amp meter socket with optional field installable

fifth terminal kit available.• 22K amps interrupting capacity (AIC) standard.• Optional mounting base can be embedded in concrete for fast, easy

installation.• Separate sealable and lockable utility termination section.• Separate sealable and lockable metering section.• Separate sealable and lockable customer section with a load center

for “always on” loads that include a main circuit breaker, 20 (125 or 200 amp model) or 14 (100 amp model) blank breaker spaces and a circuit directory to document configuration.

Note

All meter form and bypass options

available to meet utility requirements.

Page 51: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

51

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Stocked Pedestals*Optional Fifth Terminal Kit

Main CB Contactor amperage

Meter Socket Typeamp Spaces

CP3B51110A22SL1 K3865 100 1,3 60 Ringless socket with lever bypassCP3B52110A22SL1 K3865 200 1,2,3,4 100 Ringless socket with lever bypass

COMMERCIALPEDESTALS

Commercial PedestalsSwitched Load Center Series | Custom Designs Available

Notes

• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.

Typical Applications

Traffic signals, parking lots, highways & athletic

field lighting

CP3B11110A22SL1

CP3B “SL” SeriesSwitched Load Center Series1Ø3 wire 120/240V or 208Y/120V

Milbank’s Switched Load Center Commercial Pedestals are designed not only to provide power for various loads, but also to switch specific loads on and off under certain conditions. A photoelectric cell is used for these controlled loads, and an optional time clock is also available.

Features

These units include everything required for remote site service:

• NEMA 3R construction.• Expandable: load centers allow for future expansion without costly

modifications.• All units feature 200 amp meter socket with optional field installable fifth

terminal kit available.• 22K amps interrupting capacity (AIC) standard.• Optional mounting base can be embedded in concrete for fast, easy

installation.• Separate sealable and lockable utility termination section.• Separate sealable and lockable metering section.• Separate sealable and lockable customer section with a control circuit

including PE receptacle, Lexan® window, glare shield, Hand-Off-Auto (HOA) switch, contractor controlling a 16-circuit load center for controlled loads, a pre-mounted DIN rail and pre-wired connector to add an optional “plug-and-play” time clock kit for PE on and TC off operation and a circuit directory to document configuration.

• A load center for “always on” loads that includes a main circuit breaker, a control power circuit breaker, a switched load center main breaker, nine (125 or 200 amp model) or 11 (100 amp model) blank breaker spaces and a circuit directory to document configuration.

Note

All meter form and bypass options

available to meet utility requirements.

Page 52: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

52

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Standard Pedestals*Optional fifth Terminal Kit

Main CB Load Center Circuits Meter Socket Type

CP3B54120B22 K3865 2-200 amp (2) 12 circuit1 Ringless with lever bypassCP3B5411JB22 K3865 320 amp (400 max) 0 Ringless with lever bypass

COMMERCIALPEDESTALS

Commercial Pedestals400 Amp Series

Milbank’s 400 Amp Commercial Pedestal is designed to provide a weather and vandal resistant metered enclosure for various loads and distribution. Each pedestal has been designed to handle a wide range of applications using standard, stocked configurations. • Choice of a single main breaker or twin service disconnect

breakers gives flexibility to the pedestal design. • Optional distribution with feed-thru lugs below the service

disconnect breakers allows the pedestal to handle numerous applications.

• Typical applications include remote homes where the metering is best located at the curb side or other remote area. The pedestal can also provide power to secondary residence, on-site business, workshop, irrigation, lighting, security or other secondary load.

• Available in custom colors to match home or landscaping.

Features

These units include everything required for remote service:• Type 3R construction• Main circuit breaker or dual service disconnects• Expandable: load center units allow for future expansion

without costly modifications• Optional mounting base can be embedded in concrete for

fast, easy installation• Separate sealable and lockable utility termination section

with lug termination• Separate sealable and lockable metering section • A separate sealable and lockable customer section with a

circuit directory and a print pocket to hold all documentation• Meter socket options include ring type with bypass studs,

ringless with heavy duty lever bypass, or K-Type bolt-on

Typical Applications

Remote site service for residential and commercial job sites.

CP3B1411JB22

Notes

• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.• Stud utility landing is standard. Lug kits are available from factory.

• Units with load centers have (2) #6-250 sub-feed lugs on each load center. (Each load center is 200 amp rated and UL Listed with: Siemens, General Electric and Cutler-Hammer plug-in style circuit breakers.)

Page 53: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

53

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Features

• 3Ø4W, 480Y/277 volt• One technician can install in under an hour with use of Milbank’s pre-drilled box pad• All units are UL listed and service entrance rated• Fused disconnect with accessible handle through the deadfront• HOA and push button start• Separate accessible utility side with pre-wired landing lugs• NEMA rated starters (sizes 1-5)• Soft start units sizes 30HP-150HP• 30 amp fuse block for pivot pre-wired in the unit• White powder coated paint finish helps keep components cooler • Options include: • Hour meter • Chemical injection receptacle • Multiple injection receptacle • Multiple 30A fuse blocks possible

COMMERCIALPEDESTALS

Commercial PedestalsCP3B “IR” Irrigation Control Series

Stocked Pedestals Exterior Cabinet NEMA Rating

CP3B0281UMWIR04 White 4CP3B0281UMWIR03 White 3CP3B0181UMWIR02 White 2

Notes

• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.

Milbank’s “IR” Series Irrigation Pedestals install quickly and simply – often in less than an hour with a single technician—a fraction of the time typically needed for strut farm and other installation set ups. Additionally, the pedestal comes pre-wired, so the technician simply drops in the pre-drilled concrete box pad, fastens the pedestal and runs the wires. Prewired landing lugs are provided in a separate utility side so that there is no more need to wrestle with hard-to-bend wires. Simply run the utility wire up and land on the lugs. With both the motor starter and disconnect in the same enclosure, all the controls are housed in a safe, lockable pedestal that protects against vandalism and energy theft.

Typical Applications

Power pedestal for irrigation systems or other pump control

applications.

CP3B0281UMWIR04

Page 54: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

54

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Commercial PedestalsCP3B “BBS” Battery Backup Series

COMMERCIALPEDESTALS

Milbank’s BBS Series Commercial Pedestals are designed to provide battery backup power for various loads, and to switch specific loads on and off under certain conditions; a photoelectric cell or time clock to control lighting circuits, as an example. Metered and non-metered power distribution options are available. The back-up power pedestal is designed to handle the vast majority of todays back-up power requirements. By using 19” rack design, shelves can be adjusted to accommodate the required batteries and manufactures DC to AC inverters, transfer switches and other related equipment. This design gives the user a wide range of design and configuration options. Complete turnkey, ready to power-up pedestals are offered along with basic units ready to accept batteries and inverters supplied by others.

Features

• Type 3R construction• 100 through 320 amp meter socket with the option of

either a ring type socket (conforms to EUSERC 308) with or without test/bypass blocks or a heavy duty ringless socket with lever bypass

• Separate sealable utility termination compartment• An isolated separate customer section with service

disconnects, power distribution options and power control • 19” wide rack in customer compartment for easy layout of

equipment• Battery trays• Thermostat with cooling fan• Filtered louvers for heat rise flow through ventilation• Three point door latch (key or pad lockable)

Options

• Manual bypass switch• Transfer switch for generator

power back-up• Generator inlet receptacles 30A

through 200A • Pad lockable provision for

receptacles• Police access door

• Metered load center distribution• Non metered load center

distribution• Photo electric controls (for street

lighting)• Time clocks• HOA switches• Contactors

• GFI duplex receptacles• Thermostat for heating control• Heating pads or elements• Roll out shelves for batteries• Surge arrestors and lighting

arrestors

Typical Applications

Metered emergency uninterrupted power for traffic intersections, wireless, phone and communications equipment, parking lots,

camera and security locations

CP3B5111TCAWSP1

Page 55: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

55

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

COMMERCIALPEDESTALS

Commercial PedestalsCP3B “Power Transfer” Series

Typical Applications

Traffic intersections, cell sites, cable TV, pump and lift stations requiring utility power with backup generator power

Milbank’s Power Transfer Series Pedestals provide non metered AC power, distribution, surge suppression, mechanical interlock and stand-by generator receptacle— all in a neat, compact pedestal.

Features

• 120/240V 1Ø3W thru 277/480V 3Ø4W ratings• Metered or unmetered units• Choice of EUSERC ring type or ringless meter sockets• 60 amp thru 400 amp ratings • UL Listed Type 3R rated• Pad lockable, isolated utility compartments• 20 amp GFI convenience receptacle• Lockable recessed generator receptacle door • Utility and generator indicator light options• All stainless steel hardware• Galvanized steel, aluminum or stainless steel cabinet

options• Custom designs available

Typical Applications

Traffic intersections, cell sites, cable TV, pump and lift stations requiring utility power with

backup generator power

Page 56: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

56

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

COMMERCIALPEDESTALS

Commercial PedestalsCP3BB “CT Metered” Series

Typical Applications

Large homes, pumping & lift stations, motor control, water treatment plants, EV charging stations, commercial buildings, large remote service

requirements, commercial and industrial control systems

Milbank’s CT Metered Series Commercial Pedestals are designed to be used where a smaller service package would be a better choice over large 3R rated combination switchboards. These pedestals have amperage ratings of 400 to 800 amps at voltages up through 480 volt three phase.

Features

• UL Listed, freestanding Type 3R service• A low profile CT pedestal• All utility equipment is isolated in separated pad

lockable and sealable compartments • Separate customer compartment designed to hold

distribution and control equipment• Dead front customer construction• Optional mounting base• Optional construction in steel, aluminum and stainless

steel.• Wide choice of powder paint colors

Page 57: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

57

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

COMMERCIALPEDESTALS

Commercial Pedestals CP3A “Slimline” Series

Typical Applications

Roadway lighting and signage, wastewater

treatment facilities, parks and landscaping, and any application where physical

space is at a premium

Milbank’s Slimline Series Commercial Pedestals provide a sleeker, smaller footprint and wireway access on the side of the unit rather than the back, allowing maximum flexibility to place the pedestal in tighter spaces.

Features• UL Listed as service equipment• 100 or 200 amp• Vandal-resistant, secure and attractive design• Customer compartment with distribution and control equipment with

swing dead front door, secured with both a hasp/latch and draw latch outer door

• Utility metering compartment protected with a hinged hood, increasing resistance to meter vandalism

• Small footprint• Wireway located on left side of pedestal for utility incoming wire,

allowing pedestal to be mounted with back very close to a wall (14")• Available in 12" and 20" widths and 50" and 63" (metered) and 43"

(nonmetered) heights• Includes a print pocket for plans and drawings• 200 amp main available• Voltage range: 120V–480V• Compatible with both ringless and ring type meter sockets, 4–7

terminals• Available in a wide array of colors, including but not limited too all ANSI

powder coated paint colors upon request• Pedestal mounting base option saves time and labor to install on a

cement pad—no anchor bolts required• Powder-coated G90 galvanized steel, raw, anodized or powder-coated

aluminum and stainless steel exterior options

“Slimline” Series Direct Bury Extension• No need for concrete• Bolts directly to unit• Easy, modular design• Ships in a smaller package• Increases project flexibility• Easier to handle and install• Utilizes a stabilizer foot to prevent leaning over time• Pedestal and extension can be installed within 30 minutes

Notes

• Currently only built in 14 guage steel• Only available for 12” pedestals

Page 58: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

58

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Watthour Meter FormsStandard Forms | Transformer Rated or Self-Contained

WATTHOURMETER FORMS

SC SC TR TR TR

TR SC SC SC SC

TR TR SC SC TR

TR TR SC SC TR

TR TR TR

2 and 3-WIRE FORMS1S & 2S

2 and 3-WIRE FORMS1S & 2S with BYPASS

2-WIRE FORM 3S5th Term. 9 o’clock

2-WIRE FORM 3Swith BYPASS

2-WIRE FORM 3S5th Term. 6 o’clock

2-WIRE FORM 3Swith BYPASS

2 ELEMENT3-WIRE NETWORK

FORM 12S 5thTERM. 9 o’clock

2 ELEMENT 3-WIRENETWORK FORM 12S

with BYPASS5th Term. 9 o’clock

2 ELEMENT 3-WIRENETWORK FORM 12S

with BYPASS5th Term. 6 o’clock

2 ELEMENT3-WIRE NETWORK

FORM 12S 5thTERM. 6 o’clock

3-WIRE FORM 4S 3-WIRE FORM 4SWITH BYPASS

2 or 3 ELEMENT3Ø4W Y or

Y FORM 14SFORM 15S

Y FORM 16S

2 or 3 ELEMENT3Ø4W Y or

FORMS 14S & 15Swith BYPASS

2 ELEMENT3Ø4W Y orY FORM 7SFORM 24S

with BYPASS

2 ELEMENT2Ø3W, 2Ø4W, 3Ø3W

FORM 5S

2 ELEMENT Ø3W,2Ø4W, 3Ø3W FORM 5S with

BYPASS

2 ELEMENT2Ø3W, 2Ø4W, 3Ø3W

FORM 13S

2 or 3 ELEMENT2Ø3W, 2Ø4W, 3Ø3W

FORM 13S withBYPASS

2 or 3 ELEMENT3Ø4W Y orY FORM 9SFORM 8S

2 or 3 ELEMENT3Ø4W Y or

FORMS 8S & 9SFORMS 8S & 9S

with BYPASS

2 ELEMENT3Ø4W YFORM 6S

2 ELEMENT3Ø4W YFORM 6S

with BYPASS

TR = TRANSFORMER RATEDSC = SELF CONTAINED

Page 59: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

59

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Meter FormsReference Information

METERFORMS

++

ILINE (BONDED)N

C.T.LOAD

2 ++

DIAGRAM D

P1 P2 C+1 C2C+

2PN C1

C.T.

DIAGRAM D1∅3W or 3W Network with 2 C.T.’s

2 Stator Meter - Form 5S8T Socket, Test Switch #TS07-0105

++

1LINE

C.T.LOAD2

P1 C+1

++

3

++

PT PT

DIAGRAM E

P3 P2 C1 C+3 C3

C.T.

DIAGRAM E3∅3W “∆” with 2 P.T.’s & 2 C.T.’s

2 Stator Meter - Form 5S8T Socket, Test Switch #TS07-0105

++

1LINE

C.T.LOAD2

P1 C+1

++

3

DIAGRAM F

P3 P2 C1 C+3 C3

C.T.

DIAGRAM F3∅3W “∆” with 2 C.T.’s2 Stator Meter - Form 5S

8T Socket, Test Switch #TS07-0105

+

+

C.T.LOAD

P1

+

+

P3 PN C+ C+

C.T.

C.T.

++

(BONDED)

DIAGRAM G

C C C+ C

1

LINE23N

DIAGRAM G3∅4W “Y” with 3 C.T.’s

2 1⁄2 Stator Meter - Form 6S13T Socket, Test Switch #TS10-0109

+

+

1

LINE

C.T.LOAD2

P1

+

+3

P3 PN C+

N

C.T.

C.T.

++

(BONDED)

+ +

PTPT

+ +

DIAGRAM H

C C+C+ CC

DIAGRAM H3∅4W “Y” with 2 P.T.’s & 3 C.T.’s

2 1⁄2 Stator Meter - Form 6S13T Socket, Test Switch #TS10-0109

+

+

1

LINE

C.T.LOAD2

P1

+

+3

P3 PN C+

N

C.T.

C.T.

++

(BONDED)

P2

DIAGRAM I

C C+ C C+ C

DIAGRAM I3∅4W “Y” or “∆” with 3 C.T.’s“Y” 3 Stator Meter - Form 9S“∆” 2 Stator Meter - Form 8S

13T Socket, Test Switch #TS10-0109

+

+

1

LINE

C.T.LOAD2

P1

+

+3

PN C+

N

C.T.

C.T.

+

+

(BONDED)

+ +PT PT

++

P3

PT

+ +

DIAGRAM J

P2 C C+ C C+ C

DIAGRAM J3∅4W “Y” with 3 P.T.’s & 3 C.T.’s

3 Stator Meter - Form 9S13T Socket, Test Switch #TS10-0109

DIAGRAM A

(ALT.LOC.)

++

+

+

ILINE

(BONDED)N C.T. LOAD

P1 PN C+1 C1

P.T.

DIAGRAM A1∅2W with 1 P.T. & 1 C.T.

Single Stator Meter(2W1∅) - Form 3S5T Socket, Test Switch #TS04-0101

(ALT.LOC.)

++I

LINE

(BONDED)N C.T.

LOAD2

DIAGRAM B

P1 PN C+1 C1

DIAGRAM B1∅3W with 1 C.T.

Single Stator Meter (2W1∅) - Form 3S5T Socket, Test Switch #TS04-0101

++

ILINE (BONDED)N

C.T.LOAD

2

P1 P2 C+1 C+

2 C2C+2

++

DIAGRAM C

C.T.

DIAGRAM C1∅3W with 2 C.T.’s

Single Stator Meter (3W1∅) - Form 4S6T Socket, Test Switch #TS07-0105

Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory pre-wiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram.

Page 60: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

60

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

This table is for concentric stranded conductors only. For cables with compact conductors refer to NEC. Refer to latest NEC Code or Local Codes for updated requirements.

TypeConductor Size

(AWG/kcmil)Conduit Trade Sizes (Inches)

1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4

THHN,THWN,

THWN-2

12 9 16 26 46 62 102 146 225 301 387

10 6 10 17 29 39 64 92 142 189 244

8 3 6 9 16 22 37 53 82 109 140

6 2 4 4 12 16 27 38 59 79 101

4 1 2 4 7 10 16 23 36 48 62

3 1 1 3 6 8 14 20 31 41 53

2 1 1 3 5 7 11 19 26 34 44

1 1 1 1 4 5 8 12 19 25 35

1/0 1 1 1 3 4 7 10 16 21 27

2/0 0 1 1 2 3 6 8 13 18 23

3/0 0 1 1 1 3 5 7 11 15 19

4/0 0 1 1 1 2 4 6 9 12 16

XHH,XHHW,

XHHW-2

4 1 2 4 7 10 16 24 37 49 63

2 1 1 3 5 7 12 17 26 35 45

1/0 1 1 1 3 4 7 10 16 22 28

2/0 0 1 1 2 3 6 9 13 18 23

4/0 0 1 1 1 2 4 6 9 12 16

250 0 0 1 1 1 3 5 7 10 13

350 0 0 1 1 1 2 3 6 7 10

500 0 0 0 1 1 1 2 4 5 7

750 0 0 0 0 1 1 1 3 4 5

MAXIMUM NUMBER OF CONDUCTORS IN CONDUITTable from 2008 NEC Code Reference: Rigid Metal Conduit

Conduit, Ampacity & SCCRReference Information

CONDUIT, AMPACITY &

SCCR

Page 61: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

61

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Energization of Electrical EquipmentImportant Information for Installers

ENERGIZATIONOF ELECTRICAL

EQUIPMENT

Before Energizing1. Give equipment a thorough visual examination to determine that: A. No shipping or installation damage exists. B. Proper clearances have been maintained. C. All connections have been made. D. Equipment is clean and dry.2. Make a thorough examination to: A. Verify tightness of all bolted connections (see table below). B. Manually operate all circuit breakers, switches, relays, etc. C. Check rigidity of all mountings, bus bars and components. D. Use test equipment to check continuity of circuitry and integrity of insulation.3. All switches and circuit breakers should be in the “off” position.4. Verify that manual meter bypass (if applicable) is in non-bypass position.5. Install cover and/or close doors.6. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization.

When EnergizingUse caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

After EnergizingSecure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation.

Important NoteIn addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment.

* Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.CU: CopperAL: Aluminum

Nominal Size

Joint DescriptionHead Type

Torque(Inch Lbs.)Screw Nut

10 Brass Brass Nut or Extruded Hole All 20-25 inch lbs.

10 Steel Copper or Aluminum Busbar ≤ 1/8" All 25-30 inch lbs.

10 Steel Steel Nut or Extruded Hole; CU or AL Busbar > 1/8" All 30-35 inch lbs.

12 Steel Aluminum Extruded Hole All 30-35 inch lbs.

12 Steel Steel Nut or Extruded Hole All 40-50 inch lbs.

1/4 Steel Aluminum Extruded Hole All 40-50 inch lbs.

1/4 Steel Steel Nut or Extruded Hole; CU or AL Busbar All 50-60 inch lbs.

5/16 Steel Aluminum Extruded Hole Hex 60-70 inch lbs.

5/16 Steel Steel Nut or Extruded Hole; CU or AL Busbar Hex 100-150 inch lbs.

3/8 Steel Steel Nut Hex 150-200 inch lbs.

1/2 Steel Steel Nut Hex 200-250 inch lbs.

Recommended Torque for General Applications*

Page 62: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

62

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Materials & FinishesReference Information

MATERIALS& FINISHES

Materials

Finish

Ratings & Compliance

The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute.

Steel Quality

16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90)14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.

Steel Sheet

Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.Bus Bar: Alloy; 6101-O & 6063-O

Aluminum Extrusion

3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064–.125

Aluminum Sheet

Electrolytic copper with tin plating in most applications.

Copper Sheet & Bus

• In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds.

• Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds.

• Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers.

Insulating Materials

Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory.

Process

Zinc-coated with a chromate dip.

Metal Fastners

All Milbank electrical enclosures in this catalog are rated “Type 3R Enclosure” unless specified otherwise on the product’s page. All enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code. UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 414, File E30202), Test Switches (UL 414, File E62531), Power Outlets (UL 231, File E90945), Panelboards (UL 67, File E32628) and Pullout Switches (UL 1429, File E133062). Additional standards are utilized as applicable: Meter Sockets (ANSI C12.7), Test Switches (ANSI C12.9) and Panelboards (NEMA PB-1).

Ratings & Compliance

Page 63: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

63

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Index

850........................................................466002......................................................466003......................................................466116......................................................46243210-CTC3R .....................................35304410-CTC3R .....................................35363612-LC3R-SP-WB ............................35484812-CT3R-WB .................................355T8K2 ...................................................47A7514 ...................................................45A7515 ...................................................45A7516 ...................................................45A7517 ...................................................45A7518 ...................................................45A7551 ...................................................45A7551 ...................................................45A8110 ...................................................45A8111 ...................................................45A8112 ...................................................45A9064 ...................................................45A-GP .....................................................46BL7474 .................................................47CP-21 ....................................................46K1047 ...................................................46K1190 ...................................................47K1350 ...................................................26K1350 ...................................................46K1350L .................................................46K1539 ...................................................26K1539 ...................................................46K1540 ...................................................26K1540 ...................................................46K1540L .................................................46K1541 ...................................................26K1541 ...................................................46K3082 ...................................................46K3083 ...................................................46K3356 ...................................................47K3441 ...................................................46K3442 ...................................................46K3865 ...................................................47K4527 ...................................................47K4528 ...................................................47K4977-EXT ............................................47K4977-INT ............................................47K5400-BRIDGE-2POS ...........................39K5935-10GR .........................................39K5935-11GR .........................................39

K5935-2/1450 .......................................39K5935-36GR .........................................39K5935-41 ..............................................39K5935-54 ..............................................39K5T .......................................................47K8180 ...................................................46M5-144 .................................................46Q115.....................................................44Q115H ..................................................44Q120.....................................................44Q120H ..................................................44Q125.....................................................44Q125H ..................................................44Q130.....................................................44Q130H ..................................................44Q135.....................................................44Q135H ..................................................44Q140.....................................................44Q140H ..................................................44Q150.....................................................44Q150H ..................................................44Q160.....................................................44Q160H ..................................................44Q170.....................................................44Q170H ..................................................44Q2100...................................................44Q2100H ................................................44Q2125...................................................44Q2125H ................................................44Q215.....................................................44Q215H ..................................................44Q220.....................................................44Q220H ..................................................44Q225.....................................................44Q225H ..................................................44Q230.....................................................44Q230H ..................................................44Q235.....................................................44Q235H ..................................................44Q240.....................................................44Q240H ..................................................44Q250.....................................................44Q250H ..................................................44Q260.....................................................44Q260H ..................................................44Q270.....................................................44Q270H ..................................................44Q280.....................................................44

Q280H ..................................................44Q290.....................................................44Q290H ..................................................44QN2150 ................................................44QN2150H .............................................44QN2150R ..............................................44QN2150RH ...........................................44QN2200 ................................................44QN2200H .............................................44QN2200R ..............................................44QN2200RH ...........................................44S4019-O ...............................................35S4020-O ...............................................35S4399-O ...............................................35S4400-O ...............................................35S8324....................................................45S8324....................................................45TS04-0101 ............................................33TS04-0102 ............................................33TS04-0103 ............................................33TS04-0104 ............................................33TS07-0018 ............................................33TS07-0022 ............................................33TS07-0049 ............................................33TS07-0059 ............................................33TS07-0105 ............................................33TS07-0106 ............................................33TS07-0107 ............................................33TS07-0108 ............................................33TS10-0109 ............................................33TS10-0110 ............................................33TS10-0111 ............................................33TS10-0112 ............................................33U1079-RRL-K3 ......................................11U1129-O-K3L-K2L ................................11U1232-RRL-KK-K1 .................................21U1233-RRL-KK-K1 .................................21U1234-RXL-KK-K1 ................................21U1252-RRL-KK-K1-BLG-SLVG ...............22U1252-RRL-KK-K1-SLVG .......................22U1253-RRL-KK-K1-BLG-SLVG ...............22U1253-RRL-KK-K1-SLVG .......................22U1254-RXL-KK-K1-BLG-SLVG ...............22U1254-RXL-KK-K1-SLVG .......................22U1255-RXL-KK-K1-BLG-SLVG ...............22U1255-RXL-KK-K1-SLVG .......................22U1256-RXL-KK-K1-BLG-SLVG ...............22U1256-RXL-KK-K1-SLVG .......................22

INDEX

Page 64: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

64

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Index

U1797-O-K3L-K2L ................................11U1797-O-K3L-K2L-BLG ........................11U1980-O-KK ...........................................9U1980-O-KK-BLG ...................................9U2120-X-K7 ..........................................12U2594-X ................................................12U2594-X-BLG ........................................12U2732-XT ..............................................25U2733-XT ..............................................25U2734-XT ..............................................25U2735-XT ..............................................25U2736-XT ..............................................25U2852-X ................................................26U2852-X ................................................27U2853-X ................................................26U2853-X ................................................27U2854-X ................................................26U2854-X ................................................27U2855-X ................................................26U2855-X ................................................27U2856-X ................................................26U2856-X ................................................27U2862-X ................................................26U2862-X ................................................27U2863-X ................................................26U2863-X ................................................27U2864-X ................................................26U2864-X ................................................27U2865-X ................................................26U2865-X ................................................27U2866-X ................................................26U2866-X ................................................27U2872-XT ..............................................24U2873-XT ..............................................24U2874-XT ..............................................24U2875-XT ..............................................24U2876-XT ..............................................24U3278-RL ..............................................10U3491-XL-200 .......................................14U3802 .....................................................6U3812 .....................................................6U3822-20GWR ........................................7U3832 .....................................................6U3862 .....................................................6U3989-XL ..............................................14U4363-X-QG-K3-K2 ..............................11U4408-O ...............................................35U4410-O ...............................................35

U4490-XL ..............................................32U4492-XL ..............................................32U4493-XL ..............................................32U4532-XL ................................................9U4835-X-2/200-BL ................................17U4881-O-50GB .......................................8U4881-O-60GB .......................................8U4905-X ................................................11U4905-X-BLG ........................................11U4908-O-11GR .....................................40U5000-XL ..............................................41U5000-XL-41 .........................................41U5000-XL-55 .........................................41U5000-XL-75 .........................................41U5059-X-2/200-K3L ..............................17U5059-X-K3L ........................................17U5100-XL ..............................................41U5100-XL-41 .........................................41U5100-XL-55 .........................................41U5100-XL-75 .........................................41U5101-XL-11GR ....................................40U5136-O ...............................................38U5136-O-100S ......................................38U5136-O-200S ......................................38U5137-O-200S ......................................38U5161-X-K3L-K2L-BLG .........................11U5168-XTL-100-KK ...............................15U5168-XTL-100-KK-BLG .......................15U5168-XTL-150-KK ...............................15U5168-XTL-150-KK-BLG .......................15U5168-XTL-200-KK ...............................15U5168-XTL-200-KK-BLG .......................15U5200-XL ..............................................42U5200-XL-41 .........................................42U5200-XL-55 .........................................42U5200-XL-75 .........................................42U5220-XL ..............................................42U5220-XL-41 .........................................42U5220-XL-55 .........................................42U5220-XL-75 .........................................42U5268-XTL-150-KK ...............................15U5268-XTL-200-KK ...............................15U5268-XTL-200-KK-BLG .......................15U5300-O ...............................................42U5300-O-41 ..........................................42U5300-O-55 ..........................................42U5300-O-75 ..........................................42U5320-O ...............................................42

U5320-O-41 ..........................................42U5320-O-55 ..........................................42U5320-O-75 ..........................................42U5750-RXL-200-BL ...............................16U5764-X-200-CB ..................................20U5765-X-200-CB ..................................20U5767-X-200-CB ..................................20U5784-O-200-CB ..................................20U5787-O-200-CB ..................................20U5796-X-400-CB ..................................20U5797-O-400-CB ..................................20U5799-O-400-CB ..................................20U5844-PXL-200-KK ...............................14U5844-PXL-200-KK-BLG .......................14U5871-XL-200 .......................................16U5882-X-KK-BLG ..................................28U5883-X-KK-BLG ..................................28U5884-X-KK-BLG ..................................28U5885-X-KK-BLG ..................................28U5886-X-KK-BLG ..................................28U5890-X-2/200-BL ................................17U5890-X-2/200-BLG .............................17U5891-X-2/200-MLK-BL .......................17U5898-O-100-KK-BLG ..........................15U5898-O-200-KK-BLG ..........................15U5902-X-KK-BLG ..................................28U5903-X-KK-BLG ..................................28U5904-X-KK-BLG ..................................28U5905-X-KK-BLG ..................................28U5906-X-KK-BLG ..................................28U5971-XL-100 .......................................13U5971-XL-150 .......................................13U5971-XL-200 .......................................13U5990-O ...............................................35U6115-X-2/200-K7L ..............................19U6227-X-400-K3L .................................18U6227-X-400-K3L-5T6 ..........................18U6227-X-400-K3L-5T9 ..........................18U6228-X-400-K3L .................................18U6228-X-400-K3L-5T6 ..........................18U6228-X-400-K3L-5T9 ..........................18U7021-RL-TG-KK ....................................9U7021-RL-TG-KK-BLG ............................9U7040-RL-TG-KK ....................................9U7040-RL-TG-KK-BLG ............................9U7040-XL-TG-KK ....................................9U7487-RL-TG-KK ....................................9U7487-RL-TG-KK-BLG ............................9

INDEX

Page 65: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

65

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by

utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must

comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications

and features shown without notice or obligation.

Index

U9551-RRL ............................................10U9701-RRL ............................................10U9701-X-QG-BLG .................................10UAP6094-O ..........................................36UAP6095-O ..........................................36UAP6096-O ..........................................36UC1299-RL ...........................................30UC1300-RL ...........................................30UC7235-RL ...........................................30UC7237-XL ...........................................30UC7444-RL ...........................................31UC7445-RL ...........................................31UC7445-RL-641 ....................................31UC7445-WL ..........................................31UC7448-RL ...........................................31UC7449-RL ...........................................31UC7460-RL ...........................................31UC7461-RL ...........................................31UC7478-RL ...........................................31UC7532-RL ...........................................31UC7636-RL ...........................................31UQFB-100 .............................................43UQFB-100-X1 .......................................43UQFB-125 .............................................43UQFB-125-X1 .......................................43UQFB-150 .............................................43UQFB-150-X1 .......................................43UQFB-175 .............................................43UQFB-175-X1 .......................................43UQFB-200 .............................................43UQFB-200-X1 .......................................43UQFBH-100 ..........................................43UQFBH-125 ..........................................43UQFBH-150 ..........................................43UQFBH-175 ..........................................43UQFBH-200 ..........................................43UQFBH-M-100 ......................................43UQFBH-M-125 ......................................43UQFBH-M-150 ......................................43UQFBH-M-175 ......................................43UQFBH-M-200 ......................................43UQFP-100 .............................................43UQFP-125 .............................................43UQFP-150 .............................................43UQFP-175 .............................................43UQFP-200 .............................................43UQFPH-100 ..........................................43UQFPH-125 ..........................................43

UQFPH-150 ..........................................43UQFPH-175 ..........................................43UQFPH-200 ..........................................43UQFPH-M-100 ......................................43UQFPH-M-125 ......................................43UQFPH-M-150 ......................................43UQFPH-M-175 ......................................43UQFPH-M-200 ......................................43UQFP-M-100 ........................................43UQFP-M-125 ........................................43UQFP-M-150 ........................................43UQFP-M-175 ........................................43UQFP-M-200 ........................................43USE-22-200-MB ....................................13WBJ2150 ..............................................44WBJ2200 ..............................................44Z802964-AC .........................................47Z814898-AC .........................................47Z901925-AC .........................................47Z904486-AO .........................................47Z916264-AO .........................................47Z916265-AO .........................................47

INDEX

Page 66: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.
Page 67: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.
Page 68: Indiana - Milbank · With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com IN 3/18


Recommended